3M TM Filter Housing 1BS-T/1BS-TW Series

Size: px
Start display at page:

Download "3M TM Filter Housing 1BS-T/1BS-TW Series"

Transcription

1 READ FIRST 3M TM Filter Housing 1BS-T/1BS-TW Series Operation Manual CONTENTS Introduction 1 For Your Safety 1,2 Attention to galling or seizure of treaded portions 2 Specifications 3 Part names 4 Installation and piping 5 Flushing and cleaning 5 How to assemble a cartridge 6,7 Filtration process 8 How to remove a cartridge 8 Maintenance 9 Consumables 10 Product warranty 10 Read the Manual Thoroughly for Safe and Correct Operation. Keep the Manual Carefully at Hand for Quick Reference When Required.

2 Introduction This instruction manual applies to 3M TM filter housing, 1BS-T / 1BS-TW series. Read this manual before you use the filter housing. Read this manual carefully to understand it well and use the filter housing properly. Store the manual with care after you read it and refer to it whenever necessary. If you misplace or lose the manual, inform it to us or our agent promptly. If you use the filter housing in the way different from the way described in this manual, we cannot guarantee security. Do not duplicate or reprint this manual without permission from 3M. In order that you use the housing filter safely, this manual contains pictorial indications below. Pictorial Indications In order to prevent harms to the people who use the filter housing and damages to the properties by guiding the proper usage, this manual employs pictorial indications below in relation to safety labeling and operational information including cautions. This Symbol Represents a WARNING to Ensure Safe and Correct Operation. Failure to observe this warning could result in personal critical injuries or death. WARNING This Symbol Represents a to Ensure Safe and Correct Operation. Failure to observe this caution could result in personal injuries or damages on the assets only. Please follow the instructions indicated by this symbol. Useful tips for operations. For your safety Use this filter housing below the design pressure. Otherwise, it may cause leakage or breakage. Never use gases with the filter housing. If it should be broken, there may cause damages to human bodies and WARNING properties. If you open or close the valves in an abrupt manner, the filter housing may be damaged due to pulsations of the line pressure. Besides if you apply a shock, excessive flow rate or back flow to the filter housing, it may cause damages to the cartridge or housing. Never use the filter housing in such improper ways. Never use the housing filter for corrosive fluids. In addition check the fluid in advance to see if it is appropriate to the filter housing of 1BS-T/1BS-TW. To prevent electrostatic accumulation of electricity, Use a ground wire. When you use the filter housing for high-temperature fluid, its surface will become hot. Pay enough attention when you handle the housing. When you replace a cartridge with another, release the pressure in the filter housing. Especially when you use high-temperature fluid, it may blow out. Deterioration or destruction of gaskets and others may cause the fluid used to blow out. Inspect them regularly and replace them if deterioration or destruction is detected. For the maximum allowable working pressure, working temperature, flow-rate and others, observe the conditions specified when the filter housing was selected. 1

3 When you detect anything wrong with the filter housing body or gaskets and others (e.g. damages), stop using it immediately. Attention to galling or seizure of treaded portions It is said that in general stainless steel is likely to have galling or seizure because its thermal conductivity is lower than ordinary steel and the thread surface develops larger heat and expands more. Galling or seizure can be reduced by taking appropriate actions but in fact existing technologies cannot eliminate galling or seizure as well as contamination by foreign matters completely. For the threaded portions of this device (center rod and cap nut, and center rod and cover), stainless steel is used. Therefore, please use the device in an appropriate manner while paying attention to the items described below in order to prevent galling or seizure. In order to prevent galling of stainless steel components, surface coating or appropriate lubricant should be used to reduce friction and to improve thermal conductivity. Neither special disposition nor treatment is applied for the threaded portions of this device. Please use the lubricant optimal to your working conditions. When you remove the cap nut, take the most care not to let the threaded portion contaminated by foreign matters. When you install it, fasten it with the specified torque at maximum. In case you have not removed the cartridge for a long time, the threaded portions may be solidified. In that case, check the threaded portions of the center rod, cap nut and cover if anything sticks to them after the components are removed. If anything remains, take it away before reassembling the device. When you assemble the threaded portions, first turn them a few times manually to verify there is no galling. Then, use the tools to fasten them. If leakage of the fluid used occurs to the sealing portions of the shell gasket or the nut gasket, fasten the cap nut with the specified torque at maximum. Then, if leakage cannot be stopped, the gaskets may be deteriorated, damaged or deformed. So, please replace them by new ones and fasten them again. If you forcibly fasten the threaded portions, it may cause galling. So, never fasten them with force. Please understand we do not include galling or seizure of the threaded portions of this device in our guarantee. 2

4 Specifications Design pressure 0.98MPa Head SCS14 Cover SCS14 Materials 316SS Rod & Nut 316SS Gasket PTFE s outer diameter 89.1mm Height 1BS1-T/TW 1BS2-T/TW 341mm 589mm Weight 1BS1-T/TW 1BS2-T/TW 2.8kg(max) 4.1kg(max) Major dimensions Capacity 1BS1-T/TW 1BS2-T/TW 1.4L(max) 2.8L(max) Port size Inlet/Outlet nozzle Drain nozzle 1BS1-T/TW 1BS2-T/TW 8A Rc 15A/20A/25A Rc 20A/25A Rc Vent nozzle 8A Rc 3

5 Part Names Cap nut Vent Nut gasket Vent plug Inlet Outlet Head gasket Cartridge Center rod Guide Drain plug gasket Drain Cover 4

6 Installation and Piping 1. Follow the arrow marks on the head to connect pipes. 2. Place the filter housing upright on the cover. 3. Fix the filter housing by using the pipes at the inlet and the outlet. There is no mounting seat for the fixtures. See the figure below for fixing the housing. Vent Inlet Outlet Example of piping The filter housing usually does not carry a cartridge when it is supplied. Check if it has a cartridge or not before using it. Check if the shell gasket and nut gasket have been installed properly. Install valves before the inlet and after the outlet. In addition, install the manometer to measure pressure loss (differential pressure). 4.Because a cartridge needs to be replaced, secure a sufficient space for replacement where you install the filter housing. To prevent electrostatic accumulation of electricity, Use a ground wire. Do not connect the wrong pipes to the inlet and the outlet. If you do so, you cannot filter the fluid properly. Do not forcibly pull or bend the nozzle at the inlet or the outlet of the filter housing in order to adapt it to the piping at site. If you do so, you will damage the housing. Flushing and Cleaning 1.Clean the components before assemble a cartridge to the housing. 2. For cleaning use the fluid that is compatible to the fluid that is subject to filtration. 3. If you clean (flush) the filter housing with the components in place after piping by running a compatible fluid, you should keep it running 30 minutes or longer. 4. After cleaning is finished, disassemble the components before assembling a cartridge. For the procedure of disassembling the components, refer to the section describing the procedure to remove a cartridge. 5

7 How to assemble a cartidge 1.Confirm that the center rod has been screwed into the head surely without looseness. Assemble a new cartridge to the center rod. When you assemble the guide, you should make adjustments that the guide end comes approx. 30mm below the center rod end. Insert the protruding poring in the center of the cover into a cartridge and check if the cartridge tilts or gets loose. When you assemble a 10" of 3M TM Micro-Wind TM D Series filter cartridge to 1BS2-T/1BS2-TW, put a spacer between them. A spacer is not required for other filter cartridges. In case of 10" 3M TM Micro-Wind TM D Series filter cartridge make adjustments that the guide end comes approx. 30mm below the center rod end and the guide comes between the cartridges. In case of 20"of 3M TM Micro-Wind TM D Series filter cartridge, make similar adjustments for 10" to position the guide between the cartridges. (See the figures below.) 1BS1-T/1BS1-TW Guide 1BS2-T/1BS2-TW 2. Assemble the shell gaskets and nut gaskets to the gasket grooves of the head and the cover. Inspect the gaskets before assembling and if it has deterioration or damages, replace them by new ones. In addition, check if the filter housing body has anything abnormal. 3. Assemble the shell (this applied only to 1BS-T type). 4. Hold the cover firmly and insert it from the bottom of the head. 5. Screw the cap nut and tighten it. 6. Assemble the drain plug and tighten it. Make sure that the shell is fitted in the head groove and the cover groove. (For 1BS-TW type, the shell is welled to the cover.) When you fasten the cap nut, fix the projection on the cover bottom with the wrench. The appropriate torque for fastening the cap nut is 27 to 32N-m. The drain plug and vent plug are covered with sealing tape. If the tape is peeled off, cover them with new tape. 6

8 Cap nut Vent plug Inlet Vent Nut Outlet Head Cartridge Center Guide Drain Drain Cover Use the wrench for If the guide position is not properly adjusted, the cartridge may be set while it is tilting depending on the cartridge type, which causes sealing failure of the cartridge. Deterioration or damages of gaskets may cause the fluid used to blow out. If the cap nut is not fastened appropriately, the fluid used may blow out. In addition, it may cause the center rod and cap nut had the threaded portion to suffer from galling. 7

9 Filtration process 1.Open the inlet to fill the filter housing with the fluid gradually. Make sure that the shell gasket and nut gasket are properly fitted. 2. Purge the air in the filter housing from the vent. 3. When the fluid comes out from the vent, close the inlet and tighten the vent plug. 4. Then open the inlet to pressurize the filter housing up to the working pressure. Make sure that the shell gasket and nut gasket do not have leakage. 5. If you find any leakage of the fluid, close the inlet and loosen the vent plug to depressurize the filter housing. 6. Tighten the cap nut. 7. Open the inlet again to pressurize the filter housing and check if the fluid is leaking. 8. When you find no leakage, open fully the inlet and the outlet for filtration. If you pressurize the filter housing up to the working pressure all at once, the fluid may blow out form the point where the fluid is leaking. Loosen the vent plug slowly not to let the fluid blow out. How to remove a cartridge 1. Close the inlet and the outlet to stop running of the fluid in the filter housing. 2. Loosen the vent plug to depressurize the filter housing gradually. 3. Loosen the drain plug to let out the fluid in the filter housing. 4. Loosen the cap nut and remove it 5. Remove the cover from the shell. 6. Pull out the used cartridge from the center rod. When you loosen the cap nut, you can remove the components from the head. So, hold the cover firmly not to let the components drop. Deal with the shell most carefully no to let its end have scratches. Clean up the components. Use a cleaning fluid compatible to the fluid for filtration. 8

10 Cap nut Vent plug Inlet Vent Nut Outlet Head Cartridge Center Guide Drain Drain Cover Use the wrench for Unless you depressurize the filter housing completely, the fluid may blow out. Loosen the vent plug slowly so that the fluid won't blow out. Maintenance 1.It is recommended that you should install the manometers before the inlet and after the outlet to measure pressure loss (differential pressure), so that you can learn exactly when to replace the cartridge. In order to avoid long stoppage of filtration, it is recommended that you should keep a new cartridge and gaskets and nuts at hand. 2. For replacement parts, place an order to 3M or our agents by clarifying the model, serial number, part name, part number, material and quantity. 9

11 Consumables Cartridge needs to replace after use as well. Part Name Item No. Material Quantity gasket B PTFE 1 (1BS1-TW/1BS2-TW) 2 (1BS1-T/1BS2-T) Nut gasket B PTFE 1 Product Warranty 1. This product warranty is valid for one year from the date of shipment of the product from our factory. Troubles and damages which have been occurred in the product during this period will be covered by this product warranty. 2. This product warranty covers only main body of the product, and does not cover any consumables. 3. Our obligation under this product warranty shall be limited to, at our option, repair or replacement of any product proved to be defective within one (1) year from the date of shipment. 4. Notwithstanding the preceding provisions above, this product warranty does not cover any troubles and damages which: 1 are caused by wrong use or faulty repair of the product, replacement of wrong parts, or remodeling of the products; 2 are caused by assembling a product of other manufacturers to our product; 3 are caused by natural disasters, including, without limitation, a fire or an earthquake; 4 are caused by shipment, transportation or dropping of the product after purchase; or 5 are caused by reasons that are not attributable to us. 5. Except where prohibited by law, this product warranty is made in lieu of all rights, warranties and conditions, statutory or otherwise. Thus, we will not guarantee any fitness for the customer's intended use of this product or merchantability of the products in relation to the quality, performance and instruction manual of this product. In addition we will not be responsible for any direct, indirect, special, consequential or incidental damages caused by the customer's use or inability to use of this product. 3M is trademarks of 3M Company. 3M JAPAN Limited Filter product Division JV

3-Way Ball Valve Type 23H

3-Way Ball Valve Type 23H Serial No. H-V062-E-4 contents 3-Way Ball Valve Type 23H User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

Manufacturer Kakogawa, Japan DC5S

Manufacturer Kakogawa, Japan DC5S ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1

More information

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 172-65144MA-05 (JA Series) 29 July 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 Copyright

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

Sediment strainer (Type Y)

Sediment strainer (Type Y) Installation,Operation and Maintenance Manual Serial No. H-V034-E-9 Sediment strainer (Type Y) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating

More information

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2 Serial No. H-V034-E-12 Sediment strainer (Type Y) Contents (page) (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions 2 (3) General instructions

More information

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions

More information

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT Instruction D10497 April 2015 BHP High Performance Butterfly Valves (S2, S3, S5, AA, HC, ML, T2 & T5 Shafts) Instructions These

More information

Diaphragm Valves Type 15

Diaphragm Valves Type 15 Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions

More information

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 Serial No. H-V016-E-10 Gauge Valve 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 2. General operating instructions 2 User s Manual 3. General instructions for transportation,

More information

Diaphragm Valve Type 72

Diaphragm Valve Type 72 Serial No. H-V001-E-8 Diaphragm Valve Type 72 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

SAFETY MANUAL READ FIRST!

SAFETY MANUAL READ FIRST! 966-05-XX SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V013-E-13 Swing Check Valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,

More information

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators Instructions D11033 August 2013 Instructions These instructions provide information about AFR3 Filter Regulators. They are for use by personnel

More information

Free Float Air Trap G8

Free Float Air Trap G8 172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1

More information

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual Serial No. H-V003-E-12 contents 3-Way Ball Valve Type 23 User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,

More information

Owner s Manual GLASSLINED PUMP TANK

Owner s Manual GLASSLINED PUMP TANK Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that

More information

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction Mechatronics Group OPERATION MANUAL Diaphragm Pump TD/TD2 Series TD-08, 15, 20/TD2-25 Thank you for purchasing Diaphragm Pump. Introduction This operation manual describes how to ensure safe and prolonged

More information

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual 3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL LCO-8 125 PSIG RATED FILTER UNIT MODEL LCO-8 Table of Contents I. Installation...............................................................

More information

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Pg. 1 of 10 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TBH SERIES

More information

Dual Flow Manifold Systems Instruction Manual

Dual Flow Manifold Systems Instruction Manual 3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.

More information

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade) INSTRUCTION MANUAL 300 Series Compressed Air Filters Models 302 (grade) through 317 (grade) FORM NO.: 3259480 REVISION: 01/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified

More information

Butterfly Valve Type 58 (PDCPD)

Butterfly Valve Type 58 (PDCPD) Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A. INSTRUCTION MANUAL Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HRA SERIES HR80A HR150A HR260A Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 6758511, Japan Tel:

More information

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P ) Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R434001268 (Formerly P -193419-00003) Service Information INSTALLATION Before installing this cylinder, all air lines in the system should be blown clean

More information

ACTIVAL Two-way Ball Valve with Threaded-end Connection

ACTIVAL Two-way Ball Valve with Threaded-end Connection Specifications/Instructions ACTIVAL Two-way Ball Valve with Threaded-end Connection General ACTIVAL Model VY5302A is a two-way ball valve with threaded-end connection (ISO 7-1: 1994). It proportionally

More information

AT Clutch Major Service Sizes 25, 55, 115

AT Clutch Major Service Sizes 25, 55, 115 P-1404 819-0324 AT Clutch Major Service Sizes 25, 55, 115 Installation Instructions Contents Introduction............................ 2 Warranty....................... back cover Failure to follow these

More information

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust INSTRUCTION MANUAL NOTE TO INSTALLER : PLEASE GIVE THIS MANUAL TO THE CUSTOMER AFTER INSTALLATION. AUTOMATIC FAUCET Important Safeguards Precautions Model Number and Components Before Use How to Use How

More information

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water Serial No. H-V035-E-3 Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) Contents (page) User s manual () Be sure to read the following warranty clauses of our product

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 6 BAG/CARTRIDGE CONVERTIBLE 150/300 PSIG RATED FILTER UNIT Table of Contents I. Installation...............................................................

More information

DeZURIK VPB V-PORT BALL VALVES

DeZURIK VPB V-PORT BALL VALVES VPB V-PORT BALL VALVES Instruction D10324 June 2017 Instructions These instructions provide information about. They are for use by personnel who are responsible for installation, operation and maintenance

More information

Operating and Maintenance Manual for Type S Flowmeters. M101 Rev. B Type S Flowmeters: 5 8, 3 4 and 1 with 157 & 600 Series Registers

Operating and Maintenance Manual for Type S Flowmeters. M101 Rev. B Type S Flowmeters: 5 8, 3 4 and 1 with 157 & 600 Series Registers Operating and Maintenance Manual for Type S Flowmeters M101 Rev. B Type S Flowmeters: 5 8, 3 4 and 1 with 157 & 600 Series Registers TABLE OF CONTENTS Installation & Operation... Page 1 Calibration...

More information

MODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat.

MODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat. FORM NO. 94-7276 MODEL NO. 41026-60101 & UP OPERATOR S INSTRUCTIONS HOSE REEL KIT To assure maximum safety, optimum performance, and to gain knowledge of the product, it is essential that you or any other

More information

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P -322908-00000 Replaces Part No. P-191067-00000 Service Information WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 200 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................

More information

Float Dynamic Steam Trap J10

Float Dynamic Steam Trap J10 172-65237MA-01 (J10) 12 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Float Dynamic Steam Trap J10 Copyright 2015 by TLV CO., LTD. All rights reserved

More information

MODEL 900 IMPELLER-TYPE FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual Serial No. H-V019-E-6 Constant Flow Valves User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation

More information

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves Document No.: KE-4041-00 Operation Manual KITZ EKSR Series Spring Return Type Electric Actuators For KITZ Ball Valves Thank you for choosing KITZ products. For safe and trouble-free function and performance

More information

3-Way Ball Valve Type23 Pneumatic Actuated Type TA

3-Way Ball Valve Type23 Pneumatic Actuated Type TA Serial No. H-A029-E-11 Contents (1) Be sure to read the following warranty clauses of our product 1 3-Way Ball Valve Type23 Pneumatic Actuated Type TA User s Manual (2) General operating instructions 2

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638

More information

Scale Feeder Manifold Water Filtration System Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual 3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

More information

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

Operator's Manual. Models (¾) (1) (1½ ) (2 ) (3) (4) (6) (8) OdisMatic Hydraulic Filter Series 851 Operator's Manual Models 85107 (¾") 85101 (1") 85115 (1½ ) 85102 (2 ) 85103 (3") 85104 (4") 85106 (6") 85108 (8") Content 1. Technical Specifications. 2. Materials.

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

Dual Port Manifold Water Filtration Systems Instruction Manual

Dual Port Manifold Water Filtration Systems Instruction Manual M TM Water Filtration Products Dual Port Manifold Water Filtration Systems Instruction Manual For DP1XX, DP2XX and DPXX High Flow Series Water Filtration Systems Installer: Please leave this manual with

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES INSTRUCTION MANUAL Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES LV5 / LV13 / LV13L / LV13N / LV21 LV5 / LV13 / LV21 LV13L LV13N Manufacturer

More information

SUZUKI SQ 416/420/625 M.Y TRANSMISSION SERVICE MANUAL - MANUAL - AUTOMATIC - TRANSFER - DIFFERENTIALS

SUZUKI SQ 416/420/625 M.Y TRANSMISSION SERVICE MANUAL - MANUAL - AUTOMATIC - TRANSFER - DIFFERENTIALS SUZUKI SQ 416/420/625 M.Y 1998-2005 TRANSMISSION SERVICE MANUAL - MANUAL - AUTOMATIC - TRANSFER - DIFFERENTIALS WARNING/CAUTION/NOTE IMPORTANT Please read this manual and follow its instructions carefully.

More information

Ball Valve Type 21 21α Nominal size mm (1/2-4 )

Ball Valve Type 21 21α Nominal size mm (1/2-4 ) Serial No. H-V027-E-15 Contents Ball Valve Type 21 21α Nominal size 15-100mm (1/2-4 ) (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General

More information

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge Installation, Operation, & Maintenance Manual Welker Probe Instrument Regulator with Liquid Eliminator Cartridge Model LEFRD-4SS The information in this manual has been carefully checked for accuracy and

More information

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. Industrial Turbo Meters Sizes 2" through 6" Installation & Operation Manual IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. BadgerMeter,Inc. IOM-003-15 Part No.

More information

APCO CSV-1600 SURGE CHECK VALVE

APCO CSV-1600 SURGE CHECK VALVE APCO CSV-1600 SURGE CHECK VALVE Instruction D12022 January 2013 Instructions These instructions provide installation, operation and maintenance information for APCO CSV-1600 Surge Check Valves. They are

More information

DeZURIK KUL KNIFE GATE VALVES

DeZURIK KUL KNIFE GATE VALVES KUL KNIFE GATE VALVES Instruction D11025 September 2013 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KUL knife

More information

3. Timing Belt 2-3 SERVICE PROCEDURE A: REMOVAL 1. CRANKSHAFT PULLEY AND BELT COVER

3. Timing Belt 2-3 SERVICE PROCEDURE A: REMOVAL 1. CRANKSHAFT PULLEY AND BELT COVER SERVICE PROCEDURE 2-3 A: REMOVAL 1. CRANKSHAFT PULLEY AND BELT COVER G2M0107 1) Remove V-belt and A/C belt tensioner. 2) Remove pulley bolt. To lock crankshaft use ST. ST 499977000 CRANKSHAFT PULLEY WRENCH

More information

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model. Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape

More information

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Val-Matic 1-4 Combination Air Valve (Single Housing Type) Manual No. ARCO-OM1-2 Val-Matic 1-4 Combination Air Valve (Single Housing Type) Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1

More information

Butterfly Valves ASAHI AV VALVES

Butterfly Valves ASAHI AV VALVES Serial No. H-V030-E-8 Butterfly Valves Type 56: 400mm (16 ) Body: PP, PVDF Type 75: 450-600mm (18-24 ) Body: PP, PVDF Type 56D: 400mm (16 ) Body: PDCPD Type 75D: 450-600 mm (18-24 ) Body: PDCPD Contents

More information

Butterfly Valve Type 57P

Butterfly Valve Type 57P Butterfly Valve Type 57P Contents Lever Type: 50-200 mm (2-8 ) Body Material: CPVC Gear Type: 50-200mm (2-8 ) Body Material: CPVC (1) Be sure to read the following warranty clauses of our product 1 (2)

More information

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM INSTRUCTION MANUAL Anchor Darling 1878 Swing Check Valves Sizes 1/2 through 2 Installation Operation Maintenance FCD ADENIM0006-00 Table of Contents 1.0 Physical Description and Operation of Equipment

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

MetroPrime 22MPC Self-Priming Centrifugal Pump

MetroPrime 22MPC Self-Priming Centrifugal Pump Page 1 of 6 prevent priming or reduce pump capacity. OPERATION The 22 MPC-Metropolitan Pump is a self-priming centrifugal pump and only requires priming prior to its initial start. The pump will retain

More information

Tissue Master. User Manual

Tissue Master. User Manual Tissue Master User Manual This page left blank intentionally This manual is a guide for the use of the Omni International Tissue Master and accessories. Data herein has been verified and validated. It

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 SANITARY 125 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................

More information

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES Instruction D11023 October 2016 Instructions These instructions provide information about KGN-RSB Knife Gate Valves. They are

More information

GL Ludemann Y-Strainers

GL Ludemann Y-Strainers GL Ludemann Y-Strainers Installation, Operation and Maintenance Manual English Issue 1-03/2014 - Page 1/7 GENERAL These instructions are for installing, operation and maintenance of Y-strainers fabricated

More information

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No. Serial No. H-A065-E Diaphragm Valve Type 14 Pneumatic Actuated Type AP User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3)

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,

More information

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that

More information

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES Instruction D12009 December 2012 Instructions These instructions provide installation, operation and maintenance information for APCO CVS-6000 Convertible Swing

More information

THIS WARRANTY IS IN LIEU

THIS WARRANTY IS IN LIEU Installation, Operation, Maintenance and Parts Manual for Backflow Prevention Assemblies Double Check Valve Assembly Series 2000DCA 4" 10" Double Check Detector Assembly Series 3000DCDC 4" 10" Reduced

More information

Surplussing Valve SP-COSR-16

Surplussing Valve SP-COSR-16 172-65409MA-00 (SP-COSR-16) 20 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Surplussing Valve SP-COSR-16 Copyright 2013 by TLV CO., LTD. All rights

More information

Fisher TBX Hydro Plug Fixture

Fisher TBX Hydro Plug Fixture Instruction Manual TBX Hydro-Plug Fixture Fisher TBX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 2 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

DeZURIK 24 THRU 36 RESILIENT BUTTERFLY VALVES 24" THRU 36" RESILIENT BUTTERFLY VALVES Instruction D10348 April 2015 Instructions These instructions provide information about DeZURIK 24" thru 36" Resilient Butterfly Valves. They are for use by personnel

More information

Instruction Model 18537

Instruction Model 18537 Instruction 738-556 Model 18537 LIMITED WARRANTY H. D. Hudson Manufacturing Company warrants to the original purchaser only that this product will continue to function as intended if used in accordance

More information

Nor East /9500 Series Double Seated Cage Valves. Instructions. Safety Messages. Inspection. Parts. Nor East Controls Service

Nor East /9500 Series Double Seated Cage Valves. Instructions. Safety Messages. Inspection. Parts. Nor East Controls Service 1 12 9200/9500 Series Double Seated Cage Valves Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your Nor East

More information

Fisher CVX Hydro Plug Fixture

Fisher CVX Hydro Plug Fixture Instruction Manual CVX Hydro-Plug Fixture Fisher CVX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingcom TECHNICAL SERVICE MANUAL abrasive liquid pumps SERIES 4625 SIZES f - fh SECTION TSM 410.1 PAGE 1

More information

PRODUCT OBSOLETED 4Q16

PRODUCT OBSOLETED 4Q16 Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingcom TECHNICAL SERVICE MANUAL abrasive liquid pumps SERIES 4625 SIZES f - fh SECTION TSM 410.1 PAGE 1

More information

DA Series Diaphragm Valve

DA Series Diaphragm Valve DA Series Diaphragm Valve Service Instructions Pneumatically Actuated Valve Toggle Valve Valve Valve Valves are shown with tube butt weld ends. These instructions also apply to DA series valves with any

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information

Mudhen Portable Slurry System Owners Manual

Mudhen Portable Slurry System Owners Manual Mudhen Portable Slurry System Owners Manual Industrial Contractors Supplies, Inc. 412. 824. 6933 www.icscompany.net Mudhen Manual Page 1 MUDHEN MANUAL 1 Disclaimer & Safety Notice 2 2 Safety Notice 3 3

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES

More information

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING

More information

Operating instructions Form no safety definitions

Operating instructions Form no safety definitions Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety

More information

Series 867 Reduced Pressure Zone Assemblies

Series 867 Reduced Pressure Zone Assemblies RP/IS-F-867 INSTALLATION INSTRUCTIONS Series 867 Reduced Pressure Zone Assemblies 2 1 2" 3" (65 80mm) INDEX 867-NRS Installation Instructions....................................... 2-3 Service, Repair

More information

DeZURIK PEC ECCENTRIC VALVES

DeZURIK PEC ECCENTRIC VALVES 3650-7200 PEC ECCENTRIC VALVES Instruction D10019 April 2015 Instructions These instructions provide information about PEC Eccentric Valves. They are for use by personnel who are responsible for installation,

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

DL/DS Series Diaphragm Valve

DL/DS Series Diaphragm Valve DL/DS Series Diaphragm Valve Service Instructions DL Series (Lever Handle) Valve DS Series (Round Handle) Valve Valves are shown with tube butt weld ends. These instructions also apply to DL or DS series

More information

Operating Manual. High Performance Vacuum Pump Models and 15600

Operating Manual. High Performance Vacuum Pump Models and 15600 Operating Manual High Performance Vacuum Pump Models 15400 and 15600 CoolTech High Performance Vacuum Pumps Congratulations on purchasing one of Robinair s top quality CoolTech vacuum pumps. Your pump

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M IMPORTANT 1. W. A. Kates flow rate controllers are designed to accurately regulate flows and are precision

More information

Pro Shot Grease Dispense Valve

Pro Shot Grease Dispense Valve Instructions Parts List Pro Shot Grease Dispense Valve 309032J For high pressure grease dispense. 8000 psi (55 MPa, 552 bar) Maximum Working Pressure Model No. 242055, Series B, 1/4 npt Fluid Inlet Model

More information

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N 172-65162M-03 (BT3N/MBT3N/PBT3N) 5 July 2013 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N Copyright 2013 by TLV CO., LTD. All

More information

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3 - 12 AMERICAN AVK COMPANY AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12" TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION

More information