Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)
|
|
- Domenic Hampton
- 5 years ago
- Views:
Transcription
1 Instruction Manual Installation Manual Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Thank you for your purchase of Teral (Volute) Submersible Turbine Pump. To the customers Instruct the dealer (installation contractor) to install the pump. Thoroughly read this manual to properly use the pump. Keep this manual carefully after use, and read it when needed. Note that we are not liable for any product trouble or accidents caused by improper use. To the dealers (installation contractor) Properly install the pump according to the installation manual. After the completion of installation, be sure to submit this manual to the customer. Note that we are not liable for any product trouble or accidents caused by improper installation or improper use. Contents Instruction Manual for the customer Safety precautions (Be sure to observe the following.)...1 Instructions for proper use...3 Name and function of each part...4 Troubleshooting...5 After-sales service...5 Standard specifications...6 Installation manual for the dealer (installation contractor) Safety precautions (Be sure to observe the following.)...7 Installed pump system and names...9 Instructions for installation...10 Control panel...12 Wiring work...13 Anti-freeze measures...14 Test operation...14 Teral Inc.
2 Instruction Manual Safety precautions Be sure to observe the following. The following symbols and labels indicate the instructions that the user must observe in order to prevent personal injury and property damage. Levels of possible injuries and damage as a result of improper use in defiance of the instructions are classified by the following symbols and labels. WARNING CAUTION indicates that incorrect handling may lead to death or severe injury. indicates that incorrect handling may lead to injuries or property damage. The following symbols indicate the types of instructions to be observed. (The following are only part of all symbols.) This symbol indicates "prohibition" that you must NOT do. This symbol indicates "mandatory" actions that you must do. WARNING Never disassemble, repair, or modify the product. Do not operate the control panel or ground fault interrupter, or other electric devices with wet hands. Do not disassemble It may lead to ignition or malfunction, thus causing injuries. For repairs, contact the dealer (installation contractor). An electric shock may occur. Do not damage the submersible cable, apply an excessive force to it, or bundle it. If the submersible cable or above-ground wires are damaged, do not use the product. A fire or electric shock may occur. A fire or electric shock may occur. Instruct the dealer (installation contractor) to repair them. Do not put anything heavy on the submersible cable or the above-ground wires, pinch them, or modify them. It may damage the submersible cable or above-ground wires, thus causing a fire or electric shock. 1
3 WARNING Do not use the product while the door of the control panel is open. Do not put anything inside the control panel. It may cause rainwater or dust to enter the control panel. As a result, insulation degradation or other problems may occur, thus resulting in an electric shock or fire. It may cause overheating, thus resulting in ignition and fire. Do not perform Zero discharge operation for over 10 minutes. Do not run the product in mud. It may make the water hot, thus resulting in an electric shock, injury, or accident. An electric shock or accident may occur. Do not fix the position of the reset button of the motor protective relay with tape etc. It may overheat the motor or the wires in the event of trouble, thus resulting in ignition and a fire. If the motor protective relay is tripped, contact the dealer (installation contractor). Be sure to turn off the power before maintenance or inspection. An electric shock or injury may occur. CAUTION Do not open the door of the control panel. Never run the pump dry (when it is not submerged in water). An electric shock or accident may occur. A fire, electric shock, or accident may occur. If the product is not running properly, immediately turn off the power and contact the dealer (installation contractor). If water does not flow out, immediately turn off the power and contact the dealer (installation contractor). 2
4 Instruction Manual Safety precautions Be sure to observe the following. CAUTION If you do not use the product for a long time, be sure to turn off the power. It may cause an electric shock through insulation degradation or a fire through electric leak. If the product does not run or there is anything wrong, immediately turn off the power. It may cause an electric shock, or electric leak or short circuit, thus resulting in a fire. For repairs or inspection, be sure to instruct the dealer (installation contractor) from which you purchased the product. Instructions for proper use Pay attention to the discharge rate. The discharge rate may suddenly decrease when air is drawn from the strainer (suction opening) or the strainer is clogged with dirt. In such a case, contact the dealer (installation contractor). Pay attention to the needle of the ammeter. If the deflection of the meter needle is large or the current exceeds the rated value, contact the dealer (installation contractor). Shut the cock of the compound pressure gauge. Keeping the cock open may damage the compound pressure gauge by a shock during startup or stop. If no water has been pumped out for over 3 or 4 days, open the water tap to run water for a while before use. Water in the pump or in the piping may be cloudy. Even if you do not plan to use the pump for a long time, run it periodically (once a month or so). For maintenance and safety, it is recommended to inspect the insulation resistance and operating conditions (electric current, vibration, discharge rate, etc.) periodically (once a month or so). Contact the dealer (installation contractor). 3
5 Instruction Manual Safety precautions Be sure to observe the following. Be sure to confirm the following installation points from the dealer (installation contractor). If the product is for indoor use, confirm that measures are taken against water leakage. If water flows out during repairs or inspection or in the event of trouble, it may drench surrounding areas and downstairs, thus resulting in serious compensation issues. Check that no ground wire is connected to a gas pipe or water pipe. An explosion or electric shock may occur. Confirm that the product is securely grounded and that the dedicated ground fault interrupter is installed. An electric shock may occur in the event of trouble or electric leak. (You are required by law to connect a ground wire.) Check that measures are taken against freezing of the above-ground section and the pipe. Even in a warm region, an unexpected cold wave in winter may freeze and damage the above-ground section and piping. Name and function of each part Refer to page 9 for the installed system of the pump and the above-ground section. Refer to the separate Instruction Manual for the control panel. 4
6 Instruction Manual Troubleshooting If there is a problem, carry out troubleshooting according to the following table. If the problem still persists, contact the dealer (installation contractor). Problem Possible Cause Action No rotation of motor (The motor does not run.) The power (ground fault interrupter) is turned off. Turn on the power (ground fault interrupter). The motor is running, but no water flows out, or the discharge rate is low. The sluice valve of the above-ground section or a valve installed on the pipe is shut. Open the sluice valve and the valve on the pipe. Instructions If the light comes on at any alarm indicator of the motor protective relay, such as the overcurrent indicator or open-phase indicator, be sure to instruct the dealer (installation contractor) to inspect the unit. After-sales service For repairs, handling, maintenance, and other work for the product, contact the dealer from which you purchased the product. Before instructing the dealer to repair the unit, check the items shown in the "Troubleshooting" on this page. If the problem still persists, turn off the power and the ground fault interrupter, and then contact the dealer (installation contractor) from which you purchased the product. 5
7 Instruction Manual Standard specifications SSTM type (all liquid contact parts are made of stainless steel) Bore (mm) Item Liquid to be pumped Pump Submersible motor Structure Material Starter type Material STM type Item Liquid to be pumped Pump Submersible motor Structure Material Starter type Material Liquid quality Fresh water Liquid temperature 0 to 40 C Chlorine content Contained sand quantity PH 5.8 to 8.6 Max. allowable chlorine content: 200 mg/l Max. allowable sand quantity: 50 mg/l (Max. allowable grain size: 0.1 to 0.25 mm) Motor output (kw) 0.4 to to to to 15 Suction opening Type Impeller Bottom Sectional type Closed Casing SUS 304 Impeller SUS 304 Type Number of poles, phase, voltage Shaft SUS 420J2 or SUS kW to 7.5kW 11kW, 15kW Canned type 2-pole, 3-phase 200V Full voltage starting (Direct on line starting) Star-delta starting Insulation class Up to 3.7kW output: Class B 5.5kW or higher: Class F Class F Flange Frame Up to 3.7kW output: SUS kW or higher: SUS304 SUS304 Shaft Up to 3.7kW output: SUS kW or higher: SUS431 SUS431 Lead wire Liquid quality Bore (mm) 2PNCT Special threaded flange Fresh water Liquid temperature 0 to 40 C Chlorine content Contained sand quantity PH 5.8 to 8.6 Max. allowable chlorine content: 200 mg/l Max. allowable sand quantity: 50 mg/l (Max. allowable grain size: 0.1 to 0.25 mm) Motor output (kw) 0.4 to to to to to to to 75 Suction opening Type Impeller Casing Impeller Type Number of poles, phase, voltage Middle or bottom Sectional type Closed FC200 CAC406 (BC6) Shaft SUS 420J2 or SUS kW to 7.5kW 11kW or higher Insulation class Flange Frame Shaft Lead wire Canned type (up to 3.7kW output), PE winding type (3.7kW or higher) 2-pole, 3-phase 200V Full voltage starting (Direct on line starting) Star-delta starting Class B (Canned type) or polyethylene (PE winding type) SUS316 (Canned type) or FC150 (PE winding type) SUS630 (Canned type) or SUS403 (PE winding type) 2PNCT JIS10K type or JIS20K type 6
8 Installation Manual Safety precautions Be sure to observe the following. The following symbols and labels indicate the instructions that the installation worker must observe in order to prevent personal injury and property damage. Levels of possible injuries and damage as a result of improper use in defiance of the instructions are classified by the following symbols and labels. WARNING CAUTION indicates that incorrect handling may lead to death or severe injury. indicates that incorrect handling may lead to injuries or property damage. The following symbols indicate the types of instructions to be observed. (The following are only part of all symbols.) This symbol indicates "prohibited" actions that you must NOT do. This symbol indicates "mandatory" actions that you must do. WARNING Do not connect the ground wire to a gas pipe or water pipe. Do not operate the control panel, ground fault interrupter, or other electric devices with wet hands. An explosion or electric shock may occur. An electric shock may occur. Do not use the submersible cable for above-ground wiring. Use it for the connection of only up to the conduit and terminal box. It may cause overheating, thus resulting in ignition and fire. Do not use the product at any voltage other than specified. Do not damage the submersible cable. Do not apply excessive force to the cable or bundle the cable on the ground. A fire or electric shock may occur. Cut off any excess of the submersible cable exposed on the ground, and connect the cable to the control panel or the terminal box. A fire or electric shock may occur. 7
9 WARNING Do not use the pump for any liquids other than fresh water (such as salt water, oil, and chemicals) or for hot water exceeding 40 C. An explosion, fire, electric shock, or accident may occur. Carry out installation work safely and securely. Otherwise, there may be a danger; for example, the pump falls down, thus resulting in injury. Furthermore, improper work may cause water leak, electric shock, or fire. Only specialist contractors are allowed to carry out the installation work. Carry out wiring work safely and securely in accordance with the Technical Standards for Electrical Equipment and the indoor wiring regulations. Improper wiring work may cause an electrical shock or fire. Only electricians are allowed to carry out the electrical wiring work. Be sure to install the ground fault interrupter. An electric shock may occur in the event of trouble or electric leak. (You are required by law to install the ground fault interrupter.) If electric leak occurs, immediately turn off the power to prevent an electric shock. Be sure to turn off the power before grounding work. An electric shock may occur. Be sure to connect a ground wire (Class D grounding). Connect a ground wire An electric shock may occur in the event of trouble or electric leak. (You are required by law to connect a ground wire.) Connect a ground wire to the grounding terminal of the well lid; and bury the ground rod in the ground. Only electricians are allowed to carry out the grounding work in accordance with the Technical Standards for Electrical Equipment. 8
10 Installation manual Installed pump system and names Compound pressure gauge (Pressure gauge) Air valve Check valve Sluice valve Discharge bend Bedplate Submersible cable Ground wire Terminal box Lifting pipe Anchor bolts Cable tie Submersible turbine pump (volute) Suction opening (Strainer) 9
11 Installation manual Instructions for installation Clean the water tank If the water tank is not cleaned enough, remaining foreign matter (such as wood chips, bolts, nuts, iron chips, gravel, concrete chips, or shreds of rags) may clog the strainer (suction opening) and cause the sudden drop of discharge rate, which not only hinder the full performance of the pump, but also may damage the pump. Therefore, before installing the pump, be sure to clean the inside of the tank and take measures to prevent the entry of foreign matter and dirt into the tank, for example, by installing a screen at the inlet. Placement of the pump Due consideration must be given to the position where the pump is installed in the tank. Installation of the pump at an improper place may cause swirls on the water surface, thus resulting in irregular/unstable water flow, air drawing, significant decrease in pumping performance, as well as vibration and noise. Particularly when two or more pumps are installed, some measures should be taken to allow water to evenly flow into each pump. Minimum water level for operation The minimum water levels required for starting and running the pump differ depending on the pump orientation (horizontal or vertical) and the strainer position (bottom or middle) for vertical installation. Refer to the catalogue for details. When an automatic operation unit is installed, determine the water levels of turning ON (start running) and OFF (stop) the pump, referring to the following diagram. OFF (minimum level for operation) Minimum level for startup Strainer OFF (minimum level for operation) Strainer Strainer OFF (minimum level for operation) Horizontal mount rack 10
12 Installation manual Instructions for installation Check the motor sealing water Before shipping, the motor is filled with sealing water in the factory. Remove the plug and check that the sealing water is full without any leakage. For a horizontally mounted pump, perform the same check when the water is drained from the tank. * There is no need to check the amount of motor sealing water for SSTM type motors and for STM bottom suction (TU) type motors of up to 18.5 kw. STM type -- Middle suction (T type) STM type -- Bottom suction (TU type) Filler/Vent port * Use a screw driver with wide blade. Filler/Vent port The figure shows a horizontally installed pump. Even if you use a pump of this type without the horizontal mount racks, place the pump horizontally in the same way when checking the sealing water. Remove the plug of the filler/vent port and check that water is full. If it is insufficient, add fresh water (drinking water). Reinstall the plug back in place and securely tighten it. When you install the pump in a horizontal position, be sure to use the specially supplied horizontal mount rack(s) and install the pump on a level foundation. SSTM type STM type -- Bottom suction (TU type) Horizontal mount rack Horizontal mount rack CAUTION Never run the pump in the air (above water). It may cause overheating, which leads to accidents such as a fire or electric shock. Submersible cable Before and after installing the cable, be sure to measure the insulation resistance and continuity. Although this product including the submersible cable is strictly tested and inspected in the factory before shipping, check for any flaws or damage and measure the insulation resistance before installation, just in case. Be careful not to damage the submersible cable during the installation, and measure the insulation resistance and continuity again after the installation. If the insulation resistance is 10MΩ or less, contact the vendor from which you purchased the product. Instructions Be sure to measure the insulation resistance of the submersible cable. If the measured value is 10MΩ or less, contact the vendor. 11
13 Installation manual Instructions for installation Installation of the pump The pump can be used in a suspended, vertical, or horizontal position (horizontal position is only supported by the pumps of STM T type [middle suction], SSTM type, and STM TU canned type of up to 3.7kW). In any case, install sufficient supports at necessary points to support the weight of the pump, its accessories, lifting pipe, and water to be lifted as well as to absorb various vibrations and impacts generated during the operation of the pump. Be sure to install a check valve on the piping. Otherwise, back flow occurs when the pump is stopped, which causes the pump to rotate in the reverse direction and significantly shortens the life of the pump. In addition, install a sluice valve and a pressure gauge for the regulation of water flow rate and for future inspection. Instructions Only electricians are allowed to carry out the installation work. Be sure to check the voltage of supplied power. The control panel must be installed almost vertically at a place as close to the pump as possible or where you can easily carry out the operation and maintenance. Control panel Use the Teral s control panel for submersible pumps. Its 2E relay (or 3E relay) trips to protect the motor in the event of overload, open phase, or reverse phase during operation. If it is unavoidable to use a control device other than Teral s, use a protection relay equivalent to the 2E (or 3E) relay. In that case, set the tripping conditions shown in the following table. Current Tripping condition 105% No trip 150% Trip within 25 sec 500% Trip within 3 sec WARNING Do not install the control panel at a place with a risk of ignition, generation of corrosive gas, or exposure to vibrations, dust, high temperatures (40 C or higher) or high humidity (90% or higher). If the panel is of an indoor type, do not install it at a place possibly exposed to rainwater. An explosion, fire, or electric shock may occur. 12
14 Installation manual Wiring work Be sure to connect a ground wire to prevent an electric shock. Only electricians are allowed to carry out the grounding work in accordance with the Technical Standards for Electrical Equipment (Class D grounding). Connect a ground wire to the grounding terminals on the bedplate and control panel; and bury the grounding rod in the ground. Perform wiring work safely and securely in accordance with the Technical Standards for Electrical Equipment and the indoor wiring regulations. For the wiring work between the power supply and the control panel as well as between the control panel and the terminal box, the users must provide wiring materials on their own and perform wiring work in accordance with the Technical Standards for Electrical Equipment and the indoor wiring regulations. The voltage applied to the motor must be within ±10% of the rated voltage during operation. Use wires thick enough to keep a voltage drop at the terminal box within 5% of the rated voltage during operation. If you need to connect an extra cable to the supplied cable for extension, use a cable thick enough to keep a voltage drop along the cable within 5% of the rated voltage during operation. WARNING Do not submerge any connected points of the extended cable in water. An electric shock may occur. Keep the voltage imbalance of each phase within ±2.5%. For the connection of the control panel, refer to the Instruction Manual for the control panel. Check the rotation direction normal or reverse. Open the sluice valve about a half-turn to one turn. Shut the cock of the compound pressure gauge. Turn on the switch of the control panel. Shut the sluice valve, read the compound pressure gauge, and then open the sluice valve about one turn. Total shutoff head (m) Reading of the compound pressure gauge (m) + Minimum water level for operation (m) If both sides of the above equation are roughly equal, the motor rotates in the normal direction. If the rotation is reverse, change the connection according to the following diagram to switch to the normal direction. Direct on line starting Terminals at operation panel Star-delta starting Terminals at operation panel To main switch To motor To main switch To motor Swap V with W. Swap V1 with W1, and W2 with U2. Instructions Only electricians are allowed to carry out the wiring work. Be sure to check the voltage of supplied power. 13
15 Installation manual Anti-freeze measures (Be sure to read the following instructions even if the product is used in a warm region.) Even in a warm region, an unexpected cold wave in winter may freeze and damage the above-ground piping. Therefore, be sure to take the following measures against freezing. Heat insulation with heat insulating materials Wrap felt or other material around the following above-ground section to keep them warm: discharge bend, check valve, sluice valve, and the exposed area of piping. Bury any horizontal piping in the ground. (Determine the depth of piping to be buried depending on the temperature and the nature of the soil in the region.) In a region where the outside air temperature is especially low, construct a concrete pit or shed; and wrap a heat insulating material around the exposed areas of the above-ground section and piping. If a concrete pit has been constructed, provide a heat insulating material to the inside of the pit. Instructions For the pits and shed, provide space to allow for repairs, inspection, and lifting. In addition, construct them to allow for draining. Test operation WARNING Do not run the product if the insulation resistance between the control panel and the submersible motor is not higher than 1 MΩ. A fire or electric shock may occur. Open the sluice valve a half-turn to one turn. Shut the cock of the compound pressure gauge or the pressure gauge. Turn on the switch of the control panel. When water flows out, shut the sluice valve, open the cock of the compound pressure gauge or the pressure gauge, determine whether the rotation direction is normal or reverse, and ensure that the motor rotates in the normal direction. (To determine the rotation direction, refer to "Check the rotation direction -- normal or reverse" on page 13.) Open the sluice valve gradually to regulate the water flow until the water discharge rate reaches the specified value. Instructions Be sure to check the water level in the tank before starting the operation. If the pump is operated without water or without being submerged in water, the ammeter indicates light load but the pump runs dry, thus leading to an accident or trouble. 14
16 Head Office 230, Moriwake, Miyuki-cho, Fukuyama-city, Hiroshima, , Japan Tel Fax
Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM
Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial
More informationSelf-Priming Centrifugal Pump Model: SP3 / SP / MSP / MTP SP3-e / SP-e / MSP-e / MTP-e
Instruction Manual Self-Priming Centrifugal Pump Model: SP3 / SP / MSP / MTP SP3-e / SP-e / MSP-e / MTP-e Do not carry out operation, inspection or maintenance of the pump until you read this manual and
More informationcause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.
Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section
More informationMulti-stage Immersion Type VKB Series
Coolant Pump Instruction Manual Multi-stage Immersion Type VKB Series VKB Series WARNING Do not hold the strainer (wire net) of the pump point at the handling of this product. Doing so may cause the strainer
More informationcause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.
Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section
More informationOPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.
17236733/B-10011-5 LSC Submersible Residue Dewatering Pump LSP Self-Priming Residue Dewatering Pump OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD. INTRODUCTION Thank you for selecting the Tsurumi LSC
More informationMulti-stage Immersion Type
Coolant Pump Instruction Manual Multi-stage Immersion Type VKA/VKC Series WARNING Do not hold the strainer (wire net) of the pump point at the handling of this product. Doing so may cause the strainer
More informationInstallation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps
Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation
More informationInstallation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps
Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps EI-700-005 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to
More informationOperation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves
Document No.: KE-4041-00 Operation Manual KITZ EKSR Series Spring Return Type Electric Actuators For KITZ Ball Valves Thank you for choosing KITZ products. For safe and trouble-free function and performance
More informationOperation Manual Model: PPSSS Submersible Slurry Pump
ABN 17 154 031 802 21 Ginger St, Paget Mackay Qld Australia 4740 PO Box 5709, Mackay Mail Centre Qld Australia 4741 Ph: +61 07 4998 5070 Fax: +61 07 4952 1944 Mobile: +61 0409 827 290 Email: admin@pricepumpsaustralia.com.au
More informationThank you for selecting the GD submersible grinder pump.
GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6
More informationMatala. VersiFlow Series. Instruction and Maintenance Manual
VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and
More informationGARDEN HOSE UTILITY PUMP
GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before
More informationSubmersible Stainless-Steel Cutter Pump OPERATION MANUAL
17240534/B-10040-7 BQ CQ Submersible Stainless-Steel Channel Impeller Pump Submersible Stainless-Steel Cutter Pump SFQ Submersible Stainless-Steel Centrifugal Pump OPERATION MANUAL INTRODUCTION Thank you
More informationWilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions
Wilo SP Series Submersible Utility Pumps ETT ETT24-10.25 Installation and operating instructions 1. PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can be damaged during
More informationCat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units
Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling
More informationPL Submersible, Semi-Vortex, Water Feature Pump
TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and
More informationAUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust
INSTRUCTION MANUAL NOTE TO INSTALLER : PLEASE GIVE THIS MANUAL TO THE CUSTOMER AFTER INSTALLATION. AUTOMATIC FAUCET Important Safeguards Precautions Model Number and Components Before Use How to Use How
More informationGeyserMax-Flow Series
GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800
More informationSUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200
More informationL-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS
L-SERIES PUMPS Operating Manual Includes Pumps: L-305 L-310 1-877-80-PONDS www.atlanticwatergardens.com Introduction Thank you for selecting the TidalWave L-305/L-310 series pumps. Before using this pump
More informationCoolant Pump. Instruction Manual. Coolant Pump. Model : LBK-MR-e. Original Instructions
Coolant Pump Instruction Manual Coolant Pump Model : LBK-MR-e Original Instructions Limited warranties 1. In the event of a failure or breakage under proper use of the product during the warranty period,
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationTrouble Shooting Guide EWA, 3-phase (D2422)
Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Breaker tripped, no power to unit Loose wire Defective contactor or coil Close
More informationTSURUMI MANUFACTURING CO., LTD.
17200075/B-10073-5 OM COMPACT SUBMERSIBLE SEMI-VORTEX PUMP OPERATION MANUAL FOR DEWATERING INTRODUCTION Thank you for selecting a Tsurumi Compact Submersible Semi-Vortex pump for your dewatering application.
More informationEstimated Terminal Pressure Constant Control of Water Supply Unit
Instruction Manual Estimated Terminal Pressure Constant Control of Water Supply Unit NX-VFC-e Important Notice Thank you very much for purchasing the TERAL water supply unit. In order to use the water
More informationCentrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS
Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4
More informationVERTICAL MULTI-STAGES CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:
More informationOperation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18
S100 Series Centrifugal Fire Pumps Operation and Maintenance Form No. F-1031 Section 2117 Issue Date 02/22/02 Rev. Date 6/21/18 Table of Contents Safety Information-----------------------------------------------
More informationVERTICAL MULTI-STAGE CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN
More informationVolute pumps. SJ-e. 50Hz
Volute pumps SJ-e 50Hz Volute pumps Cast-iron 2-Pole, direct driven type SJ-e Applications General water supply in buildings and apartments, etc Hot and cold water circulation Supply of industrial water
More informationS200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions
S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions Table of Contents Read through the safety information and operating instructions carefully before using your S200-P Series Fire
More informationUNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSubmersible Pump Instructions. Safety Instructions
Submersible Pump Instructions Safety Instructions Before operating of this pump, read this manual and follow all safety rules and operating instructions. Before operating of this pump, read this manual
More informationGD series Submersible Grinder Pump
GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output
More informationUNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationCentrifugal Pumps. 50Hz
SJ 50Hz Non-Submersible Pump Made of cast iron Bipolar/Direct coupling type SJ model Applications General water supply in buildings and apartments, etc Hot and cold water circulation Supply of industrial
More informationISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:
ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important
More information4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause
4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on
More information- click here for pricing and ordering
www.pumpagents.com - click here for pricing and ordering No. 51-038 Mar. 01, 2006 MD-40R MD-40RX MD-40RZ(-5) Item Description Q'ty Material Part No. Part No. Part No. 1 Front Casing Unit 1 GFRPP+PTFE MD0053
More informationOWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS
OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including
More informationInstruction Manual. Coolant Pump. Model : : LHW-e / / LPW-e / / LPW-7W/ LKW-e / LFE LKW-e / LFE-e LFE / LFE-e. Original Instructions
Coolant Pump Instruction Manual Coolant Pump Model : : LHW-e / / LPW-e / / LPW-7W/ LKW-e / LFE LKW-e / LFE-e LFE / LFE-e Original Instructions Limited warranties 1. In the event of a failure or breakage
More informationAir duct switching damper
English LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT Air Duct Switching Damper MODEL P-133DUE-E Applicable Model VL-220CZGV-E Air duct switching damper Contents 1. Safety Precautions 2 2. Outside
More informationSubmersible Effluent Pump
ME45 Submersible Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2
More informationStainless Steel Centrifugal Pump SJ4S. 50Hz
Stainless Steel Centrifugal Pump SJ4S Hz Non-Submersible Pump Centrifugal Pumps Applications General water supply Industrial water Hot and cold water circulation Water supply for industrial use Distribution
More informationSUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)
SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN INSTRUCTION MANUAL Version: 20110510 (for U.S.A) PREFACE Thank you very much for purchasing World Chemical s improved magnetic drive pump Submersible.
More informationFree Float Air Trap G8
172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1
More informationSUNC3000 / Item #40885
SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3
More informationStainless Steel Centrifugal Pump SJ4S. 60Hz
Stainless Steel Centrifugal Pump SJS 60Hz Non-Submersible Pump Centrifugal Pumps Applications General water supply Industrial water Hot and cold water circulation Water supply for industrial use Distribution
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2
More informationManufacturer Kakogawa, Japan DC5S
ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1
More informationOwner s Manual GLASSLINED PUMP TANK
Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that
More informationbarmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps
Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps BP33 & BP50 0.3 & 0.5 HP @ 3450 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.
More informationVADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY
PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system
More informationProfessional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)
Model T0828 Primary pump 1/HP 200 GPH Head of 20 (6 m) SUBMERSIBLE SUMP DUPLEX SYSTEM Professional Séries Discharge: 1 1/2 ABS DWV pipe Electric cable: 9 piggyback type Oil cooled Cast iron construction
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationUZ Series. with Vortex Impeller OPERATION MANUAL
17238029/B-10024-9 INTRODUCTION UZ Series Submersible Sewage & Wastewater Pumps with Vortex Impeller OPERATION MANUAL Thank you for selecting the Tsurumi UZ Submersible Sewage & Wastewater Pumps. This
More informationGATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions
More informationPROJ. NO SECTION HYDRONIC PUMPS
SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationRead and understand this manual for safely usage.
TS02-0183 INSTRUCTION MANUAL FOR GUARD TYPE LEVEL SENSOR MODEL:FC Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for
More informationSUBMERSIBLE WATER PUMPS
SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety
More informationSMQGZ F-02 PORTABLE WATER PUMP QGZ F INSTRUCTION MANUAL
SMQGZ40-35-144F-02 PORTABLE WATER PUMP QGZ40-35-144F INSTRUCTION MANUAL The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information.
More informationInstallation & Operating Manual
Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been
More informationLDG6000SA DIESEL GENERATOR OWNERS MANUAL
LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information
More informationOperating Manual Includes Pumps: PG-9000 Part #R809606
Operating Manual Includes Pumps: PG-9000 Part #R809606 Introduction Thank you for selecting the PG Series Pumps from Lifegard Aquatics. Before using this pump please take a moment to review this manual.
More informationXLE100/150 Series Explosion-proof Submersible Sewage Pumps
Installation Manual 3493000A XLE100/150 Series Explosion-proof Submersible Sewage Pumps Models: XLE100 Series 1 hp XLE150 Series 1-1/2 hp Approved Hazardous Locations: Class 1, Div. 1, Groups C & D Class
More informationKTV/NK Series. Submersible General Dewatering Pump OPERATION MANUAL
17236124/B-10005-6 KTV/NK Series Submersible General Dewatering Pump OPERATION MANUAL INTRODUCTION Thank you for selecting the Tsurumi KTV/NK Series submersible general dewatering pump. This operation
More information8000 / 10,000 / 12,000
INSTALLATION AND SERVICE MANUAL Please fill in for future reference: MODEL: SERIAL NUMBER: DATE PURCHASED: EUROXXXXXX-SW S/N: XXXX-XXXXXX WARNING: PLEASE READ COMPLETELY BEFORE YOU INSTALL OR OPERATE YOUR
More informationSUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2
SUBMERSIBLE WATER PUMP Model Nos. CSE400A Part No. 7231100 0917 iss 2 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke Submersible Pump. This highly efficient pump is designed
More informationAUTOMATIC SUBMERSIBLE UTILITY PUMP
AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please
More informationSolenoid-driven Diaphragm Metering Pump. PZ Series OPERATION MANUAL
Solenoid-driven Diaphragm Metering Pump PZ Series OPERATION MANUAL Please read this OPERATION MANUAL carefully before use. Operating the pump incorrectly in disregard of these instructions may lead to
More informationTechnical information for LFU20-Z07-3A-X2
Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU
More informationPortable Oil Free Silent Series Compressor Operating Instructions
Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com
More informationen Pump PS PS OPERATOR S MANUAL
0154622en 002 0107 Pump PS 3 1500 PS 3 2200 OPERATOR S MANUAL 0 1 5 4 6 2 2 E N PS 3 1500/ PS 3 2200 Table of Contents 1. Foreword 3 2. Safety Information 4 2.1 Operating and Electrical Safety... 5 2.2
More informationSanwa Stainless Steel Magnet Drive Pump Model MMP. Instruction Manual
No. MMP01F(E)/1711 I.A. EDITION Sanwa Stainless Steel Magnet Drive Pump Model MMP Instruction Manual Note This instruction manual has been prepared for the personnel who will use the pump, so make sure
More informationDry installed pump type LANDY BTP.
OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The
More informationSUBMERSIBLE SUMP PUMPS
SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationSP40 Submersible Sewage Ejector Pump
Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump 6096 1009 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible
More informationOWNER S MANUAL SUBMERSIBLE UTILITY PUMP
Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More informationSTOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL
CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning
More informationVoltmaster Centrifugal Trash Pumps
Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2
More informationSKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2
Pump Installation and Service Manual SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2 NOTE! To the installer: Please make sure you provide this manual to the owner
More informationCP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.
CP series Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD. CP SERIES - Submersible utility pump The STAIRS CP series submersible utility pump is designed for dewatering and groundwater transferring
More informationInnovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual
Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION
More informationMedium and high pressure pumps
Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation
More informationW/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1
Pump Installation and Service Manual W/D/V-A1 Submersible Sump Pump W-A1 D-A1 V-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible
More informationSUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN. INSTRUCTION MANUAL Version:
SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN INSTRUCTION MANUAL Version: 150908 PREFACE Thank you very much for purchasing World Chemical s submersible magnet drive pump SUBMERSE. To effectively use
More informationENGINE DRIVEN 3 FULL TRASH PUMP
ENGINE DRIVEN 3 FULL TRASH PUMP MODEL NO: PF75 PART NO: 7230165 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0117 ISS 2 INTRODUCTION Thank you for choosing this Clarke Pump. The function
More informationSANWA STAINLESS STEEL MAGNET DRIVE PUMP INSTRUCTION MANUAL. Request to Users
SANWA STAINLESS STEEL MAGNET DRIVE PUMP MAGPAC SERIES MP/MH/ML INSTRUCTION MANUAL Request to Users This instruction manual is intended for the actual user, and should be turned over to the supervisor of
More informationSERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A
FILE No. A11-017 AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E PRINTED IN JAPAN, Jan. 2012, TDOC CONTENTS 1. Safety Precautions..................................3
More informationButterfly Valve Type 58 (PDCPD)
Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General
More informationInternal Gear Pumps Installation Manual
Internal Gear Pumps Installation Manual MEDIUM HEAVY DUTY SERIES SIZE 2 PGI100-2-005 PGI100-2-006 PGI100-2-008 PGI100-2-011 PGI100-2-013 PGI100-2-016 PGI100-2-019 PGI100-2-022 PGI100-2-025 PGI100 MEDIUM
More informationEnd Suction Centrifugal
M o d e l s 3 U / 3 U B End Suction Centrifugal Operating Instructions, Installation & Maintenance Manual Certified to NSF/ANSI 6, ANNEX G * NSF/ANSI 6 Annex G listed models: 3U EBARA International Corporation
More information