1 New software STARDEX SISU user manual STARDEX 0303, 0304, 0305, 0306, 0402, 0403 STARDEX Master Ultima STARDEX Dimas STARDEX Dimas Ultima

2 2017 STARDEX GUI NEW FEATURES ENG Foreword For more than 15 years, we have been developing and manufacturing specialized equipment for testing modern diesel injection systems for both cars and trucks, marine engines and industrial engines. The accumulated experience allowed us to rethink the work that has been done and in 2013 we started developing new products that fully meet the latest requests of our users. The main goal of this work was the creation of inexpensive, reliable, highly professional diagnostic complexes that would allow reaching a qualitatively new level of inspection and repair of modern diesel systems. In 2016, along with a new line of ULTIMA equipment for testing Common Rail systems, pump injectors and HEUI, we have released software that is universal for all STARDEX devices, both the last and the previous generation. STARDEX company is glad to present to your attention new software for testing the Common Rail system nodes, which allows to fully reveal the potential of our equipment. This instruction manual for the software covers almost all simulators and test benches of our production (STARDEX 0303, 0304, 0305, 0306, 0402, 0403, STARDEX Master Ultima, STARDEX Dimas, STARDEX Dimas Ultima). On different STARDEX devices, the functionality of the software can be significantly different!!! 2 STARDEX LTD OY FINLAND

3 STARDEX GUI NEW FEATURES ENG 2017 Table of contents Chapter Page What s new 4 Main screen 5 Main section 6 Test bench control section 9 Regulators control section 11 Injectors control section 12 Additional section. Injectors flow meter 14 Additional section. Coding 16 Additional section. Pump flow meter 17 Additional section. Current graph and current-voltage characteristics 18 Additional section. Testplan creation 21 Additional section. Injection delay measuring 24 Additional section. Info 25 Additional section. Settings 26 Additional section. Report 28 Additional section. Print 29 Pump test 31 Injector test 33 STARDEX LTD OY FINLAND 3

4 2017 STARDEX GUI NEW FEATURES ENG What s new Universal software for all STARDEX Common Rail simulators Better support for wide screen and HD monitors Simple control, automatic and semi-automatic testing modes with minimal operator involvement Extensive additional functionality for experienced users with the ability to change almost any test parameter according to your needs A lot of additional information on the tested products. Geometric gaps, strokes, adjustments, as well as cross references, usability, detailing and more Support of pressure sensors 1500, 1800, 2000, 2200, 2400 bar Measurement of the resistance, capacitance and inductance of injectors Measurement of injection delay using the STARDEX piezo sensor Detailed tooltips for each component in different languages Simple creation of testplans using template or from scratch Ability to create and save your own volt-ampere profiles Improved support for color printers and ability to save reports in PDF Ability to insert the logo and company details in the test report A huge base of injectors and pumps of major world manufacturers Frequent update of the database and constantly increasing functionality of the program Delphi C2I, Delphi C3I, Bosch IMA and Denso coding Lifetime free software updates for all STARDEX users 4 STARDEX LTD OY FINLAND

5 STARDEX GUI NEW FEATURES ENG 2017 Main screen ❷ ❸ ❹ ❶ ❺ ❻ 1. Main section. 2. Test bench control section. 3. High pressure control section. 4. Injector control section. 5. Additional section. 6. Status bar. STARDEX LTD OY FINLAND 5

6 2017 STARDEX GUI NEW FEATURES ENG Main section Pump test mode Injector test mode Search field Manufacturers list Manufacturer/OEM number Manual test mode Selected product Auto test mode Semi-auto test mode Tests list Save testplan New Test-plan/VA profile Store flow meter results Coding test mode Edit testplan Add/Remove test plan Print report Activate timers Reset flow meter results Adjusting timer Measuring timer Main Start/Stop 6 STARDEX LTD OY FINLAND

7 STARDEX GUI NEW FEATURES ENG 2017 Work with the device starts with the main section. Firstly, choose the type of device to test pump or injectors. Then choose the manufacturer and the serial number of the product. Enter part of the serial number into the search field and only the appropriate results will be displayed in the list below. The next step is to choose the test mode. In MANUAL mode, all the test parameters are set by the user. In this mode there is no testplan and there is no report on the results of testing. Current-voltage characteristics of the signal to the injectors will correspond to the current-voltage characteristics of the product with the selected number. This mode is recommended only for advanced users. In the TESTPLAN mode, a test is performed following the test plan parameters. In each test, all the set and measured parameters are preset. Navigation through the tests is done by left-clicking on the test list. Most of the parameters can be changed, according to the user s needs. In the AUTO test mode there is no ability to change test parameters and navigate through the tests. All the tests go in preset order. The CODING mode is designed for getting repair codes for injectors. As in AUTO mode all the tests go in preset order, but the number of tests is significantly bigger, which leads to longer testing time. At the end of the process, repair codes for injectors appear in the additional section in the CODING section. NEW, EDIT, SAVE, "+", "-" buttons are used when creating and editing your own testplans/profiles. STORE button saves the current flow or backflow in the report. RESET button resets the current flow or backflow value and allows you to restart the flow measurement. When ENABLE TIMING is activated by ticking the corresponding field, the flow measurement is done in accordance with preset timers. During ADJUSTING TIME, the user is given an opportunity to estimate the flow, but the final accurate measurement is displayed and automatically saved in the report only after the end of the MEASURING TIME. Using timer increases the accuracy of measurement and the repeatability of test results. STARDEX LTD OY FINLAND 7

8 2017 STARDEX GUI NEW FEATURES ENG PRINT button opens an additional window in which you can print test results on the printer, save report in PDF, change the company logo and info on the printed form, enter customer data. START / STOP button is used to start / stop testing in AUTO and CODING modes. In MANUAL and TESTPLAN modes it turns on/off test bench control section, high pressure control section, injector control section. The sequence of activation is: firstly the test bench control section, then pressure regulators and lastly injector control sections. When STOP is pressed all sections are turned off simultaneously. The user can start all the sections manually if needed (only TESTPLAN and MANUAL modes). 8 STARDEX LTD OY FINLAND

9 STARDEX GUI NEW FEATURES ENG 2017 Test bench control section Target RPM Temperature sensor 1 Pressure sensor 1 Fan indicator Fuel level Section On/Off Left/Right direction of the rotation Temperature sensor 2 Pressure sensor 2 Supply pump 3 position button Real rpm This section is available for users of kits based on STARDEX 0801, 0802, 0803, STARDEX DIMAS, STARDEX DIMAS ULTIMA work benches. In the section there are controls of the motor and booster pump of the work bench, as well as instruments for monitoring temperature and pressure in the main lines of the work bench, fuel level in the tank, cooling fans. Before starting work on the bench it is necessary to set the rotation direction of the motor (right / left) in accordance with the high pressure pump installed on the bench as well as turn on the supply pump or put it into automatic mode. At STARDEX work benches equipped with their own high-pressure pumps, the rotation direction of the pump is right by default. To activate booster pump click boost pump indicator. Clicking it again sets automatic mode of booster pump. One more click turns boost pump off. In automatic mode boost pump starts simultaneously with the start of the motor's rotation. STARDEX LTD OY FINLAND 9

10 2017 STARDEX GUI NEW FEATURES ENG To start test bench motor rotation click the motor section switch button or the main START/STOP button. The engine will gradually gain the target speed. To stop, turn off the section switch or use the main START/STOP button. 10 STARDEX LTD OY FINLAND

11 STARDEX GUI NEW FEATURES ENG 2017 Pressure regulators section Target pressure Current Current Regulator 2 activation Current Real rail pressure Section On/Off Duty cycle Regulator 1 activation Duty cycle Duty cycle Regulator 3 activation In the section there are controls of the pressure regulators. The real pressure in the rail is also displayed here. If the regulator is activated, then when the section is switched on, the signal necessary to reach the target value is sent to it. Current, duty cycle, pressure can be a target value. Double pressing of the pressure regulator activation button sets constant power on mode. In this mode, the signal to the pressure regulator is given regardless of the position of the section switch. This function can be useful when working with a pump with installed normally closed SCV. The values of current, duty cycle and pressure can be changed during testing process. STARDEX LTD OY FINLAND 11

12 2017 STARDEX GUI NEW FEATURES ENG Injector control section Pulse width Injector type indicator Section On/Off Pulse frequency Injectors selection indicators In this section there are controls of injectors. The work with this section is different for single-channel and multi-channel devices. For a single-channel device, the injector selection buttons determine which injector from the kit you are checking (only one button can be pressed). For multi-channel devices, each injector selection button is linked to a numbered cable which is connected with the injector and if multiple injectors are selected they work simultaneously. The signal to injector is characterized by the length, frequency and current-voltage profile. It is important not to be mistaken with the type of injector tested. If the current-voltage profile does not correspond with the injector under test, in some cases the injector or device may break down!!! It is very easy to check the injector type: measure resistance between the contacts of the injector using tester. In the solenoid valve the resistance is not more than a few ohms. In a piezo injector the resistance is approximately several hundred kohms. STARDEX devices generation ULTIMA are equipped with a measuring module to measure resistance, capacity and inductance of installed injectors. Also in ULTIMA generation there are more opportunities to generate a signal of the required shape and another parameterization of the signal current-voltage profile. For more details, refer to the sections "Current graph and current-voltage characteristics and "Measuring module". 12 STARDEX LTD OY FINLAND

13 STARDEX GUI NEW FEATURES ENG 2017 To send a signal to injectors, first activate the necessary injectors by clicking on the corresponding numbered indicators and then click section on button. The signal with a preset length and frequency is sent to the activated injectors. Also, when the START / STOP button is pressed in the main section, this section is started automatically immediately after setting the target pressure. STARDEX LTD OY FINLAND 13

14 2017 STARDEX GUI NEW FEATURES ENG Additional section. Injector flow meter Delivery measuring units Backflow measuring units Upper range limit Lower range limit Delivery value Backflow value This section used to measure flow and backflow of injectors. When using STARDEX devices equipped with an electronic measuring unit, measurements are made automatically. The flow measurement data is saved in the report when the MEASURING TIME timer reaches the end or when clicking STORE button in the main section. If you click RESET button in the main section, the measurement is reset and the measurement process starts again. If there is no electronic measuring unit, then the measurement should be carried out in the test bench beakers, and the results should be entered manually in the flow value field. For convenience the units of measurement can be changed from ml/min to ml/100cycles, ml/200cycles, ml/1000cycles, l/hour. If TESTPLAN or AUTO modes are selected, the upper and lower range limits for the test are displayed on the beakers. In MANUAL mode, there is no target flow data. 14 STARDEX LTD OY FINLAND

15 STARDEX GUI NEW FEATURES ENG 2017 Additional section. Coding New repair codes To start the assignment of codes to injectors, you need to choose CODING mode in the main section, select manufacturer, injector number and start the test with the START / STOP button in the main section. Upon completion of the coding process, new repair codes are displayed in this section. The function of coding injectors is only available with STARDEX electronic flow measurement system. STARDEX LTD OY FINLAND 15

16 2017 STARDEX GUI NEW FEATURES ENG Additional section. Pump flow meter Delivery measuring units Back flow measuring units Delivery value Back flow value Test info field This section serves for measuring flow and backflow of the pump, and also contains a information field describing procedures and parameters of the pump test. When using STARDEX devices with electronic measuring system (STARDEX 0305, 0306, 0104, STARDEX Ultima, STARDEX Dimas, STARDEX Stream) the flow and backflow measurement is automatic. The flow measurement data is saved in the report when clicking the STORE button in the main section. When clicking RESET button in the main section, this measurement is reset and the measurement process starts again. For convenience the units of measurement can be changed from ml/min to l/hour. 16 STARDEX LTD OY FINLAND

17 STARDEX GUI NEW FEATURES ENG 2017 Additional section. Current graph and current-voltage characteristics Current plot First phase width Voltage ❶ First phase current Second phase current Reset to defaults ❶ STARDEX LTD OY FINLAND 17

18 2017 STARDEX GUI NEW FEATURES ENG Boost voltage Boost on/off First phase width Second phase current Battery voltage First phase width Boost current First negative voltage Second negative voltage Reset to defaults ❷ ❷ 18 STARDEX LTD OY FINLAND

19 STARDEX GUI NEW FEATURES ENG 2017 The current chart of the injector serves as an additional tool for analyzing the fault of the injector. An abnormal graph may indicate short-circuited turns in the electromagnet or breakdown of the piezoelectric element of the injector. Also, the current graph serves as a tool for monitoring settings of the current-voltage profile. The first group figures show the current-voltage profile for devices of the previous generation STARDEX 0303, 0304, 0305, 0306, 0402, The second group figures show the current-voltage profile for devices of the new generation STARDEX ULTIMA. Changing profile settings is recommended only for advanced users. In rare cases incorrect values of currents and voltages can cause failure of the injector or simulator!!! STARDEX LTD OY FINLAND 19

20 2017 STARDEX GUI NEW FEATURES ENG Creating and editing a test plan It is very important to set the type of injector, current and voltage correctly. Wrong choice can damage the injector and simulator!!! Changing or creating new voltamperage profiles is recommended only to experienced users!!! There are existing testplans and current-voltage profiles that can be changed or new testplans and current-voltage profiles can be created. Click button NEW to create new or copy existing profile/testplan. No changes can be made in the current database, all changed and new profiles/testplans are stored in CUSTOM folder in the list of manufacturers in the main section. EDIT, SAVE, "+", "-" buttons are used to edit and save testplans from the CUSTOM folder. List of tests and buttons for creating/editing volt-ampere profiles and test-plans Clicking NEW button opens the window for creating a profile. Using buttons NEW and COPY in creating/changing the profile form, the user determines whether he creates a new profile or a copy of the existing profile. When creating a new profile, the user sets all values of currents and voltages, as well as the type of injector by himself. When creating a profile copy, all form fields are automatically filled with values from the profile of the selected injector. 20 STARDEX LTD OY FINLAND

21 STARDEX GUI NEW FEATURES ENG 2017 There are 3 types of injectors: COIL (Bosch, Delphi, Denso, Caterpillar, AZPI), PIEZO (Bosch, Denso, Siemens), NEG_PIEZO (Delphi piezo). ADD VA PROFILE button is used to change the values of currents and voltages and save these values to a user profile. REMOVE VA button deletes the existing user profile. Click OK button to finish creating the testplan in the CUSTOM folder or CANCEL button to cancel. Form for creating/editing the VA profile Injector type Injector number VA profile name Add/Save profile Delete profile STARDEX LTD OY FINLAND 21

22 2017 STARDEX GUI NEW FEATURES ENG After creation / editing of the profile, the newly created number of injector is automatically chosen. After, the existing tests can be edited using EDIT button. The tests can be added / removed using "+" "-" buttons. SAVE button in the main section quickly enters all the values from the right side of the screen into the test point creation / editing form. Target motor speed, target pressure, pulse width and frequency are automatically transferred. Test-plan create/edit form When clicking ADD button, the test is added to the test list and can be edited again using EDIT button or deleted using "-" button. 22 STARDEX LTD OY FINLAND

23 STARDEX GUI NEW FEATURES ENG 2017 Additional section. Injection delay Injector sensor voltage plot Maximum value of the delay Minimum value of the delay Average value of the delay Sensor sensitivity Refresh plot Reset all measured values Save data in report If the simulator is equipped with an output to the injection delay sensor or STARDEX 0502 is connected to it, the tab DELAY appears in the additional section. On the voltage plot from the sensor, you can see where the injection started. This is always the first front. SENSETIVITY parameter sets the signal level. The projection of the cross point between the first front and the signal level (in this case 1.3 volts) to the Time axis is the value of the injection delay. The received minimum, maximum and average values of the injection delay can be reset or saved in the report with the corresponding buttons. GET CHART button refreshes the voltage chart. STARDEX LTD OY FINLAND 23

24 2017 STARDEX GUI NEW FEATURES ENG Additional section. Information The additional information section contains information on the applicability of the product, cross references, spare parts numbers, as well as information on assembly strokes, dimensions, gaps. For some injectors, there is a detailed description of the location and purpose of the shims. This window is opened by clicking SHOW DETAILS button. Depending on the type and number of the selected product, the information may look different!!! 24 STARDEX LTD OY FINLAND

25 STARDEX GUI NEW FEATURES ENG 2017 Additional section. Settings Pressure sensor type Tooltips language Device type Pressure regulators configuration Fast coding Flow meter auto reset Tooltips appear interval STARDEX Dimas GUI Typically, the user goes to the settings once when the device is first started. The type of pressure sensor must be selected in accordance with the pressure sensor installed on the fuel rail. In the regulator configuration, it is necessary to set the number of pressure regulators in accordance with the simulator used. Their number can be from one to three. In the injectors configuration, it is necessary to set the number of injectors in accordance with the simulator used. Their number can be from one to six. The main language of the program is English, but tooltips for components can be displayed in different languages. Select the desired language from the appropriate STARDEX LTD OY FINLAND 25

26 2017 STARDEX GUI NEW FEATURES ENG list. In order for the tooltips not to interfere with your work, set the convenient interval for their appearance on the screen using the corresponding menu item. If you use the STARDEX DIMAS or DIMAS ULTIMA bench work, check the corresponding box. This option removes the possibility of changing the rotation direction of the bench pump. To automatically reset the flow meter values when changing tests, check the corresponding menu item. To reduce the coding time of the injectors, by decreasing the accuracy, check the corresponding box. 26 STARDEX LTD OY FINLAND

27 STARDEX GUI NEW FEATURES ENG 2017 Additional section. Report During the injectors test in AUTO or TESTPLAN mode, or during the pump test in TESTPLAN mode, a result report is generated. The first are the results of the flow tests; the data of the injection delay is in the middle; resistance, capacitance and inductance measurements are located at the bottom of the report. The report contains test names, limit ranges of values and values obtained as a result of tests. The measurement results are stored in the report by clicking STORE button in the main section or at the end of the MEASURING TIME. When redoing any of the tests, the result of this measurement in the report is overwritten. STARDEX LTD OY FINLAND 27

28 2017 STARDEX GUI NEW FEATURES ENG Print the report. Company info on a printed form In CUSTOMER tab, the customer data fields, testing date and serial numbers of the tested products should be filled in. 28 STARDEX LTD OY FINLAND

29 STARDEX GUI NEW FEATURES ENG 2017 In COMPANY tab, the fields should be filled in with company data. The company logo can also be changed or deleted here. The logo should be in JPG or PNG format. All saved PDF reports are stored in REPORTS folder on the desktop. The report can be printed or saved in PDF, using the corresponding buttons at the bottom of the form. STARDEX LTD OY FINLAND 29

30 2017 STARDEX GUI NEW FEATURES ENG Pump test Wiring diagram STARDEX STARDEX STARDEX 0104 Install the Common Rail pump and the fuel rail on the bench as shown on the diagram above. Connect STARDEX 0803 work bench and STARDEX 0104 flow meter with USB cable to STARDEX 0304 simulator. In STARDEX SISU program, select the manufacturer and serial number of the tested pump. Set the rotation direction of the pump in the program according to the installed pump. Set supply pump to the AUTO or ON mode. On the additional panel go to the PUMP section and follow the instructions in the information field. To start the test, select the test and click START button in the main section. To save test results in the report, click STORE button in the main section. 30 STARDEX LTD OY FINLAND

31 STARDEX GUI NEW FEATURES ENG 2017 To print a report, save to PDF, enter company data and customer data click PRINT button in the main section and additional window will appear. When working on a bench with high pressure, it is necessary to use a protective cover in order to avoid personal injury in case of emergency situations! STARDEX LTD OY FINLAND 31

32 2017 STARDEX GUI NEW FEATURES ENG Injector test Wiring diagram STARDEX STARDEX STARDEX 0104 Install the Common Rail pump, fuel rail and test injectors on the test bench as shown in the diagram above. Connect STARDEX 0803 bench and STARDEX 0104 flow meter with USB cable to STARDEX 0304 simulator. In the STARDEX SISU program, select the manufacturer and serial number of the tested injectors. Select the test mode. Set the rotation direction of the pump in the program according to the installed pump. Set supply pump to the AUTO or ON mode. With the injector selection buttons, activate the connected injectors according to the numbered cable. In the additional section, open FLOW section. Click START button in the main section. In AUTO or CODING modes tests are carried out from the beginning to end in order without user intervention. At the end of the process, a report or new codes of injectors are generated. 32 STARDEX LTD OY FINLAND

33 STARDEX GUI NEW FEATURES ENG 2017 In TESTPLAN mode tests are selected from the list and started by the user. The results of the test are stored in the report when STORE button is clicked or automatically after the end of MEASURING TIME. MANUAL mode is only for experienced users. It is used to reproduce specific test conditions. Saving results in the report is not available. To print a report, save to PDF, enter company data and customer data click PRINT button in the main section and additional window will appear. When working on a bench with high pressure, it is necessary to use a protective cover in order to avoid personal injury in case of emergency situations! STARDEX LTD OY FINLAND 33

COMMON RAIL PUMP AND INJECTOR TESTER STARDEX 0305

COMMON RAIL PUMP AND INJECTOR TESTER STARDEX 0305 COMMON RAIL PUMP AND INJECTOR TESTER STARDEX 0305 Safety rules for working with STARDEX 0305 device. Before using the device STARDEX 0305 (further the device ) read this manual carefully. The device should

More information

HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0304

HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0304 HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0304 Safety rules for working with STARDEX 0304 device. Before using the device STARDEX 0304 (further the device ) read this manual carefully.

More information

COMMON RAIL INJECTOR TESTER STARDEX 0601

COMMON RAIL INJECTOR TESTER STARDEX 0601 COMMON RAIL INJECTOR TESTER STARDEX 0601 1. Security information Read this operating manual carefully before using Stardex 0601 ( Device or Test bench ). The device must be connected only to the three-phase

More information

HELSINKI, FINLAND, 2018 STARDEX DIMAS ULTIMA AUTOMATIC TEST BENCH FOR COMMON RAIL INJECTORS WITH EMBEDDED ELECTRONIC FLOW MEASUREMENT AND CODING

HELSINKI, FINLAND, 2018 STARDEX DIMAS ULTIMA AUTOMATIC TEST BENCH FOR COMMON RAIL INJECTORS WITH EMBEDDED ELECTRONIC FLOW MEASUREMENT AND CODING HELSINKI, FINLAND, 2018 STARDEX DIMAS ULTIMA AUTOMATIC TEST BENCH FOR COMMON RAIL INJECTORS WITH EMBEDDED ELECTRONIC FLOW MEASUREMENT AND CODING 2018 STARDEX DIMAS ULTIMA ENG Safety rules for working with

More information

HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0402

HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0402 HELSINKI, FINLAND, 2015 COMMON RAIL INJECTORS TESTER STARDEX 0402 Safety rules for working withstardex 0402 device. Before using the device STARDEX 0402 (further the device ) read this manual carefully.

More information

Support. EMROL Your power partner

Support. EMROL Your power partner Support Support Part one What is and how to use / upgrade the software / firmware / manual How to start a capacity test Interpreting the results after a test is finished Read out the results with the BITS-software

More information

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual World Leaders in Diesel Fuel Injection Test Equipment. IFT-c Injector Function Tester Controller Operating and Servicing Manual HL048 (EN) Issue 4, H1852, August 2011 HARTRIDGE LIMITED IFT-c Operating

More information

Appendix 3 V1.1B Features

Appendix 3 V1.1B Features Appendix 3 V1.1B Features The v1.1b of the Valve Spring Tester adds several new features, which are described in this Appendix. In addition, the Automatic Spring Tester was released after the original

More information

Rally computer 3 Rally computer 3.GPS *

Rally computer 3 Rally computer 3.GPS * Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to

More information

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439 LS IGNITION CONTROLLER 19355418 Ignition Control for Carbureted LS Series Engines (24x Crankshaft Index/1x Camshaft Index, 58x Crankshaft Index/4x Camshaft Index) Parts Included Quantity Ignition Controller

More information

Instruction of connection and programming of the VECTOR controller

Instruction of connection and programming of the VECTOR controller Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring

More information

ESI[tronic] 2.0 Trainer

ESI[tronic] 2.0 Trainer Service Training Center Robert Bosch GmbH Automotive Aftermarket Diagnostics www.bosch-diagnostics.de ESI[tronic] User training Course documentation Name :... Date : from... to... Location :... This training

More information

Automotive Injection Service Solutions. Supplementary Catalog testing. service. cost-effective. innovative. quality cleaning. technology support

Automotive Injection Service Solutions. Supplementary Catalog testing. service. cost-effective. innovative. quality cleaning. technology support service testing cost-effective innovative quality cleaning technology support user-friendly diagnosis Injection Service Solutions Supplementary Catalog 2011 GASOLINE injector equipment Carbon Tech Series

More information

QUICK START GUIDE 199R10546

QUICK START GUIDE 199R10546 QUICK START GUIDE 199R10546 1.0 Overview This contains detailed information on how to use Holley EFI software and perform tuning that is included within the software itself. Once you load the software,

More information

IB INTERNATIONAL Pty Ltd OCMIS INSTRUCTION MANUAL AQUA SYSTEM 3

IB INTERNATIONAL Pty Ltd OCMIS INSTRUCTION MANUAL AQUA SYSTEM 3 IB INTERNATIONAL Pty Ltd OCMIS INSTRUCTION MANUAL AQUA SYSTEM 3 Australian Importer and Distributor - IB INTERNATIONAL Pty Ltd PO Box 5481, Manly Qld 4179 Telephone: 61 7 3348 83 Facsimile: 61 7 3348 89,

More information

Using Advanced Limit Line Features

Using Advanced Limit Line Features Application Note Using Advanced Limit Line Features MS2717B, MS2718B, MS2719B, MS2723B, MS2724B, MS2034A, MS2036A, and MT8222A Economy Microwave Spectrum Analyzer, Spectrum Master, and BTS Master The limit

More information

Caterpillar Electronic Engines Application User s Guide

Caterpillar Electronic Engines Application User s Guide Caterpillar Electronic Engines Application User s Guide Pro-Link iq IDSC Holdings LLC retains all ownership rights to the Pro-Link iq and its documentation. The Pro-Link iq source code is a confidential

More information

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL RDS For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION CREATING THE WORKING COPY INSTALLATION GETTING STARTED i iii iv v

More information

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 REV F2.0 User's Manual Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 Table of Contents INTRODUCTION...4 Starting TOOLBOX Software... 5 MAIN MENU...6 System Setup... 6 Language... 7 Select

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Service Bulletin Immobilizer System (Type 6) (Supersedes , dated February 20, 2009; see REVISION SUMMARY) February 22, 2013

Service Bulletin Immobilizer System (Type 6) (Supersedes , dated February 20, 2009; see REVISION SUMMARY) February 22, 2013 Service Bulletin 06-033 Applies To: 2007-09 MDX ALL 2007-12 RDX ALL February 22, 2013 Immobilizer System (Type 6) (Supersedes 06-033, dated February 20, 2009; see REVISION SUMMARY) REVISION SUMMARY This

More information

DFS-1000 Wiring Diagrams and PC Software Installation.

DFS-1000 Wiring Diagrams and PC Software Installation. DFS-1000 Wiring Diagrams and PC Software Installation. For Technical Support Please contact your dealer or email seellc@mchsi.com 1 Important Information - When using a conventional style ignition coil

More information

DIAGNOSIS AND CONTROL MULTIPURPOSE PLATFORM FOR MULTIBRAND FUEL INJECTION SYSTEMS

DIAGNOSIS AND CONTROL MULTIPURPOSE PLATFORM FOR MULTIBRAND FUEL INJECTION SYSTEMS DIAGNOSIS AND CONTROL MULTIPURPOSE PLATFORM FOR MULTIBRAND FUEL INJECTION SYSTEMS DIGITAL DELIVERY METERING INSTRUMENT TOTEM EDX450 NEEDED (NOT INCLUDED) Made by DITEX TECHNOLOGIES S.R.L. Copyrights reserved.

More information

Common Rail System Tester CRS-5000

Common Rail System Tester CRS-5000 Common Rail System Tester CRS-5000 Catalog Injectronix Co., Ltd. 1/13 CRS-5000 is able to test the following common rail pumps and injectors Pumps Injectors Bosch CP1 Bosch CP2 BOSCH Truck BOSCH Automotive

More information

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide Introduction: Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide The NCC-002 is capable of controlling two stages of progressive nitrous and fuel. If the NCC-002 is configured only for nitrous,

More information

Logbook Selecting logbook mode Private or business mode Administrating logbook records Reporting... 33

Logbook Selecting logbook mode Private or business mode Administrating logbook records Reporting... 33 Map display... 4 Zoom and drag... 4 Map types... 4 TomTom map... 5 Full screen map... 5 Searching the Map... 5 Additional filter options in the Map View... 6 Tracking and tracing... 7 Track order status...

More information

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App IntelliSens App For Android & ios devices Revision 2.0 17.10.2016 Overview Function flow... 3 HC1000... 4 First Steps... 5 How to Read a Sensor... 7 How to Program a Sensor... 10 Program a Single Universal

More information

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and

More information

Functional Testing & Analysis

Functional Testing & Analysis Functional Testing & Analysis We've been providing turnkey Function Test Systems with Monitoring for over 25 years. From valve testing to seat slide exercise we have sensors to fit, cables to connect,

More information

MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS

MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS INSTALLATION INSTRUCTIONS MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS NOTE: This product is applicable to pre-1966 California and pre-1968 federally certified passenger cars. It is also applicable to non-emission

More information

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller

More information

Using the Gratec Gasoline software

Using the Gratec Gasoline software Using the Gratec Gasoline software The Gratec Software is a sophisticated yet user friendly program in which configures the Gratec CNG or LPG system to perform with your vehicle. Software version 2.002

More information

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/ GRUNDFOS INSTRUCTIONS Control HVAC Installation and operating instructions Other languages net.grundfos.com/qr/i/98800750 English (GB) English (GB) Installation and operating instructions Original installation

More information

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES W SERIES IMPULSE VOLTAGE TEST SYSTEM Impulse Voltage Test System is used to generate impulse voltages from 100 KV to 2400 KV simulating lightning strokes and switching surges with energies up to 240 KJ.

More information

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER 24/7 SUNNY TRIPOWER 1 Function Availability Reactive power is necessary for the stability of the utility grid. With the functions "Integrated Plant Control" and "Q on Demand 24/7", SMA Sunny Tripower inverters

More information

Tube Bender. Machine Type - Tube Bender

Tube Bender. Machine Type - Tube Bender Tube Bender Machine Type - Tube Bender Tube Bender Control Mach4 Tube Bender Control Manual X15-250-300 Tube Bender Control Manual X15-250-400 Tube Bender Wiring Guide X15-250-300 Tube Bender Control Mach4

More information

User s Manual ENGINE IGNITION ANALYZER. General Technologies Corp.

User s Manual ENGINE IGNITION ANALYZER. General Technologies Corp. User s Manual ENGINE IGNITION ANALYZER General Technologies Corp. Table of Contents 1. Safety Rules Page 1 2. Technical Specifications Page 2 2.1 General specifications Page 2 2.2 Electrical specifications

More information

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

CurveMaker HD v1.0 2Ki Programmable Ignition programming software Contents CurveMaker HD v1.0 2Ki Programmable Ignition programming software Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Programming

More information

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL i Table of Contents Page 1. Installation Overview...1 1.1 MAXIMIZER-II Power Input...1 1.2 SOLENOID DRIVER Ground...1 1.3 Arming

More information

IGNIJET DUCATI - detailed description

IGNIJET DUCATI - detailed description IGNIJET 2007- DUCATI - detailed description 1. Hardware Connection of the main connector (illustration of the unit) "ENGINE" CONNECTOR 1. Unconnected 2. Unconnected 3. TPS throttle position sensor The

More information

USER GUIDE 1 USER GUIDE

USER GUIDE 1 USER GUIDE USER GUIDE 1 USER GUIDE 1 TABLE OF CONTENTS IN THE BOX...3 NAVIGATING THE MENUS...3 MENU LAYOUT...3 UPDATE YOUR PROGRAMMER...4 CONNECT WITH THE MOTORCYCLE...5 TUNE YOUR MOTORCYCLE...6 ADDITIONAL FEATURES...8

More information

Practical Exercise: Computation of the engine output characteristics for a 4-stroke spark ignition engine

Practical Exercise: Computation of the engine output characteristics for a 4-stroke spark ignition engine Practical Exercise: Computation of the engine output characteristics for a 4-stroke spark ignition engine Dr. Sc. (Tech.), prof. Andrei Kuleshov, Bauman Moscow Technical University, Russia The main objectives

More information

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide. 1993-2001 Dynojet Research, Inc. All Rights Reserved.. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software

More information

Common Rail System Tester CRS-4000

Common Rail System Tester CRS-4000 Common Rail System Tester CRS-4000 A Typical Package Injectronix Co., Ltd. 1/13 CRS-4000 is able to test the following common rail pumps and injectors Pumps Injectors Bosch CP1 Bosch CP2 BOSCH Truck BOSCH

More information

Technical Information

Technical Information Technical Service 2/14 ENU WE02 9 WE02 - Re-programming Instrument Cluster (Workshop Campaign) Important Note: CRITICAL WARNING - THIS CAMPAIGN INCLUDES STEPS WHERE SEVERAL CONTROL UNITS IN THE VEHICLE

More information

HAT220A ATS CONTROLLER USERS MANUAL

HAT220A ATS CONTROLLER USERS MANUAL HAT220A ATS CONTROLLER USERS MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou Henan Province

More information

HYUNDAI CIT Common Rail Injector Tester User s Manual. A, U, D, J, S, R Engine & U-II, A-II Digital Controller

HYUNDAI CIT Common Rail Injector Tester User s Manual. A, U, D, J, S, R Engine & U-II, A-II Digital Controller HYUNDAI CIT-3500 Common Rail Injector Tester User s Manual A, U, D, J, S, R Engine & U-II, A-II Digital Controller Contents. PRODUCT COMPOSITION. INJECTION TEST ) Injection Comparison Test ( Low Pressure

More information

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External T P M S Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External Table of Contents 1. PRODUCT INTRODUCTION... 2 2. NOTICE... 2 3. BLE TPMS SPECIFICATION... 3 4. BLE TPMS PACKAGE...

More information

: ANIMATION OF A POWER SYSTEM USING POWERWORLD SIMULATOR

: ANIMATION OF A POWER SYSTEM USING POWERWORLD SIMULATOR 2006-1767: ANIMATION OF A POWER SYSTEM USING POWERWORLD SIMULATOR Frank Pietryga, University of Pittsburgh-Johnstown FRANK W. PIETRYGA is an Assistant Professor at the University of Pittsburgh at Johnstown.

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

SPARKER DC-CDI-P2 HARDWARE

SPARKER DC-CDI-P2 HARDWARE SPARKER DC-CDI-P2 SPARKER DC-CDI-P2 RACE is a capacitive ignition unit for road motorcycles. The ignition unit can be programmed via a computer and it is fully tunable as regards ignition timing. It contains

More information

Connection and programming manual for. controller. (also available in the diagnostic software and at

Connection and programming manual for. controller. (also available in the diagnostic software and at Connection and programming manual for controller (also available in the diagnostic software and at www.ac.com.pl) ver. 1.5 2015-06-30 CONTENTS 1. Set-up... 3 1.1. STAG 200 GoFast connection diagram...

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the

More information

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation INDEX 1 Introduction 1.1 Features of the Software 2- Software installation 3 Open the program 3.1 Language 3.2 Connection 4 Folder General - F2. 4.1 The sub-folder Error visualization 5 Folder Configuration

More information

DKG-109 AUTOMATIC MAINS FAILURE UNIT

DKG-109 AUTOMATIC MAINS FAILURE UNIT Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-109 AUTOMATIC MAINS FAILURE UNIT FEATURES Automatic mains failure Engine control Generator protection

More information

Instruction of connection and programming of the OSCAR-N controller

Instruction of connection and programming of the OSCAR-N controller Instruction of connection and programming of the OSCAR-N controller Table of content Paragraph Description Page 1 Installation of OSCAR-N sequential gas injection system 2 1.1 OSCAR-N sequential gas injection

More information

MIC4 IGNITION CONTROLLER

MIC4 IGNITION CONTROLLER MIC4 IGNITION CONTROLLER MIC4 MOTORTECH IGNITION CONTROLLER Try the alternative. Call the nearest MOTORTECH sales partner for more information. REV.02/2015 MIC4 IGNITION CONTROLLER The economically attractive

More information

Guangzhou Junliye Import&Export Co., Ltd. CW-6H Injector Diagnostic & Cleaning System. Operation manual

Guangzhou Junliye Import&Export Co., Ltd. CW-6H Injector Diagnostic & Cleaning System. Operation manual CW-6H Injector Diagnostic & Cleaning System Operation manual OPERATING MANUAL INDEX 1. Technical Characteristics 2 2. Installation.3 3. Equipment Description..4 4. Control Board.6 5. Operation.9 I. MANUAL

More information

TUNING Training Course Material 2014 Valid for Diag4Bike V14 only On-line Multimedia User Manual is under preparation.

TUNING Training Course Material 2014 Valid for Diag4Bike V14 only On-line Multimedia User Manual is under preparation. TUNING Training Course Material 2014 Valid for Diag4Bike V14 only On-line Multimedia User Manual is under preparation www.diag4bike.eu 1 TUNING STRATEGY Tuning system is based on DIAG4BIKE diagnostics

More information

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100 PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100 1 CONTENTS Table of Contents CONTENTS... 2 INTRODUCTION... 4 Overview... 4 Features... 4 GENERAL DESCRIPTION... 5 2 List of

More information

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000 JUMO DSM software PC software for management, configuration, and maintenance of digital sensors Operating Manual 20359900T90Z001K000 V1.00/EN/00661398 Contents 1 Introduction...................................................

More information

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy!

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy! User Guide Introduction 2 A significant feature of E-Trac is the inclusion of a USB connection facility, allowing you to connect your E-Trac to a Personal Computer (PC) to download and upload detector

More information

Connection. 1. Diagnostic socket 2. Adaptor 3. Main cable 4. PC-MAX main unit 5. PC 6. Wireless adaptor

Connection. 1. Diagnostic socket 2. Adaptor 3. Main cable 4. PC-MAX main unit 5. PC 6. Wireless adaptor PC MAX Wireless VCI Connection 1. Diagnostic socket 2. Adaptor 3. Main cable 4. PC-MAX main unit 5. PC 6. Wireless adaptor PC-MAX offers --Over 40 makes, 1,000 vehicle system coverage, --including CANbus

More information

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7 SET UP MANUAL INDEX 1 Introduction 1.1 Features of the Software 2- Software installation 3 Open the program 3.1 Language 3.2 Connection 4 General - F2 4.1 The sub-folder Error visualization 5 Configuration

More information

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

BERMAD Waterworks. Insertion Flow Meter Device (IFM) IFM-MUT1222PRV BERMAD's IFM-MUT1222-PRV SENSOR is designed for measuring the flow rate of valves sized DN80 to DN600 (3-24 ). This document describes the installation process of the sensor. For larger

More information

Operation manual. ABS 911 GT3 Cup Gen.II MTH Version _V1_2018/02

Operation manual. ABS 911 GT3 Cup Gen.II MTH Version _V1_2018/02 Operation manual ABS MTH355200 Version _V1_2018/02 Contact Manthey-Racing GmbH Technical Support Rudolf-Diesel-Str. 11-13 53520 Meuspath Germany Phone: +49 (0) 2691 9338 807 E-Mail: techsupport@manthey-racing.de

More information

OMEM200 Tuning Manual 3v Series ECU. Tuning Manual OMEM200.

OMEM200 Tuning Manual 3v Series ECU. Tuning Manual OMEM200. 200 Series ECU Tuning Manual OMEM200 www.omextechnology.com 0 1 Introduction... 3 1.1 What this manual covers... 3 1.2 Notation Used in This Manual... 3 2 Software... 4 3 Sensor Setup... 5 3.1 Throttle

More information

EV110. Electric Vehicle Supply Equipment Tester. Operating Instructions

EV110. Electric Vehicle Supply Equipment Tester. Operating Instructions Electric Vehicle Supply Equipment Tester Seaward Group USA 6304 Benjamin Road, Suite 506 Tampa Florida 33634 Tel: +44(0)191 5863511 www.seaward-groupusa.com sales@seaward-groupusa.com service@seaward-groupusa.com

More information

KIA CRT Common Rail Injector Tester User s Manual. Delphi A2 U2 Engine. PIEZO, S & R Engine

KIA CRT Common Rail Injector Tester User s Manual. Delphi A2 U2 Engine. PIEZO, S & R Engine KIA CRT-3500 Common Rail Injector Tester User s Manual PIEZO, S & R Engine Delphi A U Engine Contents. PRODUCT COMPOSITION. INJECTION TEST -. Injection Comparison Test ( Low Pressure Mode ) -. Injection

More information

Preparing and programming of ESGI 2 LPG supply system manual

Preparing and programming of ESGI 2 LPG supply system manual Preparing and programming of ESGI 2 LPG supply system manual Part II Instruction of preparing and programming the ESGI system 1 Technical data of the central unit Vs Power supply voltage 0...16V V i_an

More information

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Baker PPX Power Packs

Baker PPX Power Packs Baker PPX Power Packs High voltage motor testing made easy for motor manufacturers, repair shops and plant maintenance. The Baker PPX30 Power Pack shown in combination with the Baker AWA-IV static electric

More information

Operating Instructions for WABCO Diagnostic Controller with Program Card ABS/ASR C1/C

Operating Instructions for WABCO Diagnostic Controller with Program Card ABS/ASR C1/C Operating Instructions for WABCO Diagnostic Controller 446 300 320 0 with Program Card ABS/ASR C1/C2 446 300 516 0 Edition: December 1995 Copyright WABCO 1995 WABCO Fahrzeugbremsen Ein Unternehmensbereich

More information

Samsung Modelling Guide for equest

Samsung Modelling Guide for equest Samsung Modelling Guide for equest Disclaimer The information contained in this equest Modeling Guide and in the DVM S library file (the Information ) is for informational purposes only and should not

More information

DKG-109J AUTOMATIC MAINS FAILURE UNIT

DKG-109J AUTOMATIC MAINS FAILURE UNIT DKG-109J AUTOMATIC MAINS FAILURE UNIT CANBUS VERSION FEATURES True RMS measurements Automatic mains failure ECU control and monitoring through J1939 CAN J1939 ECU warnings displayed as text Various engine

More information

Quick Start User Guide

Quick Start User Guide Quick Start User Guide 2 Pipe Flow Expert Quick Start Guide Copyright Notice 2015 All Rights Reserved Daxesoft Ltd. Owner of PipeFlow.co.uk and PipeFlow.com Distribution Limited to Authorized Persons Only.

More information

MSD Programmable Shift Controller PN 75591

MSD Programmable Shift Controller PN 75591 MSD Programmable Shift Controller PN 75591 WARNING: During installation, disconnect the battery cables. When disconnecting, always remove the Negative cable first and install it last. Parts Included: 1

More information

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External T P M S Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External Table of Contents 1. PRODUCT INTRODUCTION... 2 2. NOTICE... 2 3. BLE TPMS SPECIFICATION... 3 4. BLE TPMS PACKAGE...

More information

Diagnosing methods common rail fuel injectors

Diagnosing methods common rail fuel injectors Article citation info: OSIPOWICZ, T., ABRAMEK, K.F. Diagnosing methods common rail fuel injectors. Combustion Engines. 217, 168(1), 6-61. DOI: 1.1926/CE-217-19 Tomasz OSIPOWICZ Karol Franciszek ABRAMEK

More information

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 OPERATING INSTRUCTION Poka Patrol CNA-4mk3 Poka Patrol CNA-4mk3 To use this product properly and safely, please read this manual carefully before

More information

Versaguard MAX Console OEM Guide

Versaguard MAX Console OEM Guide Versaguard MAX Console OEM Guide TABLE OF CONTENTS SECTION PAGE 1 FUNCTION OVERVIEW 1.1 LCD INFMATION CENTER... 1 1.2 LCD QUICK BUTTONS... 2 1.3 LED INDICATS... 2 1.4 ELECTRONIC PARKING BRAKE... 2 1.5

More information

LAMBDA SENSOR CONTROLLER

LAMBDA SENSOR CONTROLLER LAMBDA SENSOR CONTROLLER INSTALLATION & PROGRAMMING MANUAL version : V1.77 -V1.79 Manufacturer: AC Spółka Akcyjna. 15-182 Białystok, ul. 27 Lipca 64, Poland tel. +48 85 7438148, fax +48 85 653 8649 www.ac.com.pl,

More information

MSD Programmable Shift Controller PN 7559

MSD Programmable Shift Controller PN 7559 MSD Programmable Shift Controller PN 7559 WARNING: During installation, disconnect the battery cables. When Disconnecting, always remove the Negative cable first and install it last. Parts Included: 1

More information

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT DESCRIPTION 1999 ACCESSORIES & EQUIPMENT Passive Anti-Theft Systems - Cougar Passive Anti-Theft System (PATS) is available on some vehicles. The system is passive in that it does not require any activity

More information

Section 55 Chapter 6

Section 55 Chapter 6 Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main

More information

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed

More information

Experiment 6: Induction

Experiment 6: Induction Experiment 6: Induction Part 1. Faraday s Law. You will send a current which changes at a known rate through a solenoid. From this and the solenoid s dimensions you can determine the rate the flux through

More information

TYPE 5867 PORTABLE Q METER

TYPE 5867 PORTABLE Q METER IMPORTANT: Please read these instructions carefully before operating instrument SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference TINSLEY, A

More information

System Background and Operation

System Background and Operation Pty Limited 1/48 Racecourse Road RUTHERFORD NSW 2320 Telephone: (02) 4932 0111 Facsimile: (02) 4932 0222 E-mail:hyden@hydeneng.com.au ABN: 17 129 010 902 ENVIROSPRAY Manual Manual Number: 06500976A Manual

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

SimMotor User Manual Small Engine Simulator and HIL V COPY RIGHTS ECOTRONS LLC All rights reserved

SimMotor User Manual Small Engine Simulator and HIL V COPY RIGHTS ECOTRONS LLC All rights reserved V2.3.1 SimMotor User Manual Small Engine Simulator and HIL V2.3.1 COPY RIGHTS ECOTRONS LLC All rights reserved Http://www.ecotrons.com Table of Contents Read before you start:...1 Why do I need SimMotor?...2

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact

More information

Abrites Diagnostics for Nissan/Infiniti

Abrites Diagnostics for Nissan/Infiniti Abrites Diagnostics for Nissan/Infiniti User Manual Version: 4.5 www.abrites.com Manual version: 4.5 1 List of Revisions Date Chapter Description Revision 24.06.2009 Initial version of the document. 2.0

More information

Features: Enhanced throttle response, excellent acceleration, linearity and driveability

Features: Enhanced throttle response, excellent acceleration, linearity and driveability 120A/150A ESC X-Car 120A/150A Series Sensored/Sensorless Brushless ESC for 1:8 scale Car or Truck Thank you for purchasing the X-Car Brushless Electronic Speed Controller (ESC). The X-Car 1:8 Scale 120A/150A

More information

Maximiser Progressive Controller

Maximiser Progressive Controller Maximiser Progressive Controller Street & Race Model Owner's Manual 44 (0) 01302 834343 www.noswizard.com Introduction Congratulations on purchasing the Maximiser for the ultimate in progressive nitrous

More information