PV-250 Track Relay. Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil
|
|
- Clemence Houston
- 5 years ago
- Views:
Transcription
1 [UNION SWITCH & SIGNAL IL~j 645 Russell Street Service Manual 4574-M Batesburg, SC PV-250 Track Relay Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil Installation, Operation and Maintenance July, 1979 C-7/ , Union Switch & Signal Inc. Printed in U.S.A. An Ansaldo Signal Company
2 I
3 SERVICE OPERATING VALUES FOR 90/83.3 HZ PV-250 TRACK RELAY WITH 115 VOLT LOCAL 440 TURN TRACK COIL Pc. No. N and N342555~8l3* LOCAL AMPERE AT 115 VOLTS, 90 HZ SPEC. EU 5277 MANUAL4574 M Information for adjustment is given in Service Manual Check the current operating values using Figure 17 of Service Manual 5036 with 15 volts or more at the track transformer secondary. This will insure that the resistance in series with the track winding is sufficient to provide suitable phase relations. Test circuit Figure 18 should be used if voltage values are to be checked also. Test circuit figures 19 and 20 may be used instead of Figures 17 and 18, but usually they are less convenient. TABLE 1. TEST OPERATING VALUES FOR 90 HZ Torque Mm. Drop Away Inch-Grains Pick-Up Full Stroke % of Actual PU Volts Amps Volts Amps Shop Field The above values are 13% higher than ideal and apply to test from single phase supply with resistance in series with track winding. It is recommended that relays be taken out of service if the Drop-Away falls below the value shown for field test. TABLE II. OPERATING VALUES AT IDEAL PHASE RELATIONS FOR 90 HZ Pick-U Full Stroke Mm. Drop Away Volts Amps Volts Amps % of Actual PU The above values are based on ideal phase relations, track amperes lead line volts by *These relays are identical except the 813 relays are used w{th a 90 volt local energization. July, / UNION SWITCH & SIGNAL DIVISION AMERICAN STANDARD INC. I SWISSVALE, PA 15218
4 UNION SWITCH & SIGNAL TABLE III. OPERATING VALUES AT IDEAL PHASE RELATIONS FOR 83.3HZ Pick-Up Full Stroke Mm. Drop Away. olts Amps Volts Amps I 2 of Actual PU The above-values are based on ideal phase relations, track amperes leading local volts by TABLE IV. TEST CALIBRATION VALUES FOR 83.3HZ IPick-Up Amps I Full Stroke Amps I Mm. Release I % of Pick U I PERIODIC MAINTENANCE All vital relays must be inspected and tested at least every two (2) years. The tests and inspections are to include: pick up current, drop away current, timing of slow operating and timing relays, visual inspection of contacts for damage or misalignment, corrosion, or other contamination of parts, loose parts inside of cover, broken seal, and cracked or broken cover. ~1 All vital relays installed in locomotive or car carried equipment are to be inspected and tested at least every two (2) years as above. In addition, every four (4) years the relays are to be removed from service and adjusted, repaired and tested. Relays not passing the above stated tests and inspections must be replaced and not returned to service until the operating characteristics and conditions are in accordance with US&S specifications. p. 2, 4574 M
5 MAINTENANCE NOTICE PV-250 AC VANE RELAY Inspection for Loose Counterweights and Loose Trunnion Screw Locknuts This Maintenance Notice covers PV-250 ac Vane Relays manufactured from 1984 to Sept. 1988, and with the following Part Numbers and applicable Service Manuals: RELAY PART NO. N N RELAY MANUAL SM-4574A N SM-4574B N N N SM-4574C N SM-4574D N N N N SM-4574E SM-4574F N SM-4574G N SM-4574H N SM-4574J N SM-4574L N N SM-4S74M N SM-4574N How to find the date of manufacture? Look at the serial number of the relay. In the serial number to be found on the nameplate of the relay, the first two digits stand for the week, and the next two digits stand for the year of manufacture of the relay. For example, serial number was made during the 45th week of 1985, and was the 115th item of its particular part number. UNION SWITCH & SIGNAL INC. A ne.nb~r 01 the ANSALDO Group 5800 CORPORATE DRIVE PIVJSBURGH, PA October, 1988 COPYRIGHT 1988, UNION SWITCH & SIGNAL INC PRINTED IN USA
6 WARNING THE FOLLOWING PROCEDURE INVOLVES THE OPENING OF A VITAL RELAY. THIS PROCEDURE MUST BE PERFORMED BY INDIVIDUALS QUALIFIED TO WORK ON VITAL RELAYS. IF THE FOLLOWING INSPECTION IS TO BE DONE IN THE FIELD. BE CERTAIN TO OBSERVE ALL RULES REGARDING THE SAFE MOVEMENT OF TRAINS BEFORE REMOVING THE RELAY FROM SERVICE. Instructions for inspecting for loose counterweights and loose trunnion screw locknuts: 1. Remove the bottom cover from the relay. This exposes the contact assembly. extreme caution not to disturb the adjustment of the contacts. Remove nameplate access to the counterweight assembly on the vane crank. Exercise to gain 2. Carefully rotate the vane so that the counterweight assembly is visible. This will reveal one or more counterweights, with or without a locknut, on the counterweight screw. 3. As shown in the figure below, check to determine if (a) the counterweight and locknut are tight, (b) at least two threads are visible on the counterweight screw end, and (c) the split screw end is slightly spread apart. Tighten any loose counterweights and locknut. 4. Perform a visual inspection of the relay. Check for rubbing vane, debris inside the relay, and for obviously misaligned contacts. Check to see that the vane is approximately centered and that it has the correct amount of end play (0.010 to inch). Readjust if required. Check the vane for freedom of movement. Check to see that the operating arms, clips and bushings are in their proper position and are free to move. Using a wrench, check the trunnion locknuts for tightness. Tighten any that are loose. 5. Perform an electrical calibration test in accordance with the applicable service manual. If the relay passes the field limit requirements outlined in the service manual, apply glyptal to the exposed threads of the counterweight screw and the trunnion locknut, as shown in the figure below. The relay can then be sealed and placed in service. 6. If the counterweight screw end cannot be spread, or if any of the checks or calibration tests do not pass, send the relay to US&S Service & Repair in Augusta, Georgia for free-of-charge service. REMOVE NAMEPLATE 0 COUNTER- WEIGI-IT [Cfl ASSEMBLY ~/ VANE SI-IAFT r 0 BOttOM VIEW (COVER REMOVED) MAKE SURE TRUNNION LOCKNUT IS flght 00 NOT DISTURB CONTACTS DURING SERVICING U 0 TWO Ti-IREADS EXPOSED (MIN.) 7 APPLY GLYPTAL MAKE SURE LOCKNUT IS TIGHT AGAINST COUNTERWEIGHT COUNTERWEIGHTS WITH LOCKNUT
7 I
8 p
PV Element AC Vane Relay
SM 4574B 1000 Technology Drive, Pittsburgh, PA 15219 645 Russell Street, Batesburg, SC 29006 PV-250 2-Element AC Vane Relay 25 Hz Part Number N322555-002 Installation Operation Maintenance Copyright 2019
More informationUNION SERVICE SPECIFICATION NUMBER SU A
UNION SERVICE SPECIFICATION NUMBER SU-1862 -A UNION SWITCH & SIGNJU,.,... SWISSVALE, PAe DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY DN-10 TRAIN CONTROL SPECIAL SLOW DROP-AWAY RELAYS ********************
More informationSERVICE MANUAL
DN-18 SLOW PICK-UP. SLOW DROP-AWAY RELAYS SERVICE MANUAL 2 3 9 0 Supplemental Service Specifications: SU-2390-A SU-2390-B SU-2390-C DN-18 Slow Pick-Up, Ordinary Drop-Away Relay DN-19 Slow Drop-Away Relay
More informationSL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance
I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC 29006 Service Manual 3011 SL-6 & SL-6A Outlying Switch Lock Field and Shop Maintenance April, 1979 A-79-500-1496-3 1979, Union Switch & Signal
More informationCHEC"'- INSTRUCTION UNION SWITCH & SIGNAL.. SWISSVALE, PA. DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY
CHEC"'- INSTRUCTION JUL S PA.MPH LET NUMBER U- 565 UNION SWITCH & SIGNAL.. SWISSVALE, PA. DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY j ELECTRO-PNEUMATIC CUT-OUT RELAY For Automatic Speed Control Car-Carried
More informationI N I s14 J 914 J
SERVICE MANUAL 457 4-N VITAL PLUG-IN AC VANE RELAY PV-250 Part Numbers I N342555- I s14 J 914 J THIS. MANUAL SUPERS20ES SM4574-N DATED JULY 1983 March, 1985 ID0019F-DN0005F A-3/85-150-2609-1 UNION SWITCH
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More information3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay
41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.
More informationCOM Overcurrent Relay
41-102.1B COM Overcurrent Relay Figure 1: COM-5 Class 1E Relay (Front View) 9664A28 Photo Figure 2: COM-5 Class 1E Relay (Rear View) 9664A29 Photo Photo needed here 2 COM Overcurrent Relay 41-102.1B 3
More informationFN-27 FLASHER RELAY SERVICE MANUAL 4519 * * * * * * * * * * * * * * * *
An American-Standard Company SERVICE MANUAL 4519 FN-27 FLASHER RELAY * * * * * * * * * * * * * * * * This manual contains information for shop repair, adjustment and calibration of FN-27 Flasher Relays
More informationSERVICE MAN.UAL 4551-F~.
WABCCJ ~ PN-150P PLUG-IN POWER TRANSFER RELAYS (4-POINT) PC. NO. SERIES N322508-702, N322508-703 SERVICE MAN.UAL 4551-F~. CONTENTS Section I II III IV v VI VII VIII IX x XI XII GENERAL.INFORMATION ARMATURE
More informationSyntron F-450-C Electromagnetic Vibratory Feeder
Syntron F-450-C Electromagnetic Vibratory Feeder SPRING REPLACEMENT COIL AND/OR CORE REPLACEMENT OPERATION PARTS LIST Thank you for buying your equipment from FMC. This manual will help you to understand
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More informationC. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View
Figure 1. CA-16 Front View Figure 2. CA-16 Rear View 2 2.1. Restraint Elements Each restraint element consists of an E laminated electromagnet with two primary coils and a secondary coil on its center
More informationwww. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE
r \ FIG. 1. Cutaway View of Typical Switch. I.L. 46-723-1 DESCRIPTION INSTALLATION MAINTENANCE INSTRUCTIONS THE INERTEEN AND OIL INSULATED FEEDER SWITCH provides complete switching facilities in a minimum
More informationINSTALLATION MANUAL HYDRAULIC HOSE REEL
INSTALLATION MANUAL HYDRAULIC HOSE REEL 1 TABLE OF CONTENTS SECTION PAGE SECTION PAGE 1 HOW TO ORDER PARTS 3 MAINTENANCE SCHEDULE... 11 1.1 HOW TO ORDER PARTS... 2 1.2 MODEL IDENTIFICATION... 3 2 INSTALLATION
More information~ SERVICE SPECIFICATION SU-4522-A ~
WRBCC ~ ~ SERVICE SPECIFICATION SU-4522-A ~ ORP-66 PLUG-IN D. C. SWITCH OVERLOAD RELAY I. GENERAL The ORP-66 D. C. switch overload relay is furnished primarily for the overload protection of high voltage
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationP. Sub 4 184A404. Sub 3 876A220
Figure 1. Type CRN-1 Relay Without Case. 1 = Directional Unit (D). 2 = Timer Unit (T). 3 = Indicating Contactor Switch (ICS). Sub 4 184A404 Sub 3 876A220 Figure 2. Internal Schematic of the Single Trip
More informationAutomatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative percentage
More informationFebruary, Swissvale, Pa. INSTRUCTION PAMPHLET U-5623-A MASTER RELAY FOR AMPLIFIER FOR UNION CODED CAB SIGNAL EQUIPMENT
INSTRUCTION PAMPHLET U-5623-A MASTER RELAY FOR AMPLIFIER FOR UNION CODED CAB SIGNAL EQUIPMENT February, 1949 1 UNION SWITCH & SIGNAL COMPANY Swissvale, Pa. .. U. S. & S. Co. U-5623-A contact adjustments
More informationwww. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below
Instructions for Cast Resin Bushing, 15 KV & Below Fig. 1 Cast Resin Bushing The Westinghouse Cast Resin Bushing, used for voltages 15KV and below, is made by casting an insulating resin around the conductor.
More informationRELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES
BELL SYSTEM Plant Series PRACTICES SECTION 040-811-701 Issue 1, June, 1962 AT&TCo Standard RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION I I!
More informationPN-250BE D.C. HIGH EFFICIENCY BIASED PLUG-IN RELAY. (li to 007) TABLE OF CONTENTS ARMATURE AIR GAP ADJUSTMENT CHECK OF CONTACT OPENINGS
SERVICE MANUAL 4563 PN-250BE D.C. HIGH EFFICIENCY BIASED PLUG-IN RELAY (li322550-001 to 007) TABLE OF CONTENTS Section I II III IV v VI VII VIII ARMATURE AIR GAP ADJUSTMENT PERMANENT MAGNET INDICATOR CONTACT
More informationInstruction Bulletin. Jockey Pump Controller
Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and
More informationElectromagnetic Industries LLP
GROUND FAULT CURRENT DETECTION GFM Relay (Model 252 & 262) The GFM system is designed for electrical protection, not for personnel protection Application: These Class 1 (Model GFM) Ground Fault protection
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More informationType CRN-1 Reverse Power Relay 50 and 60 Hertz
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-251.2P Effective: June 1991 Supersedes I.L. 41-251.2N Dated April 1988 ( )Denotes Change
More informationF O R M. Rotating Biological Contractor Drives Installation and Maintenance Manual. 8368E Revised October Table of Contents.
Rotating Biological Contractor Drives Installation and Maintenance Manual Power Transmission Solutions Regal Beloit America, Inc. 7120 New Buffington Road Florence, KY 41042 Application Engineering: 800
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationUBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit
More informationAUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO REEL -AS AUTOMATIC CORD REEL WITH AUTO SAFE MODEL #: 091-220-20-120-AS INPUT: 120 Volts, 50/60 Hz, 20 Amps File: IM_091-220-20-120-AS_revA.indd Rev: A Revised By: JM Date: 06-09-2015
More informationSelf-Adjust Clutch Installation Guide
Self-Adjust Clutch Installation Guide 0 STOP! READ CAREFULLY BEFORE INSTALLING CLUTCH This clutch must be installed by a qualified installer. Improper installation or failure to replace or resurface the
More informationOCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008
OCTOPUS SERVICE PROCEDURE - SP007 REV NEW 15-FEB-2008 APPLICABLE MODELS a. Both styles of Octopus Hydraulic 38mm Bore Linear Drive. (LAM = Linear Actuator Mounted & LAR = Linear Actuator Remote) REQUIRED
More informationService Instructions. Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A
Service Instructions Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A Service Instructions Syntron Light-Capacity Electromagnetic Vibrating Feeders Models: F-T01-A and DF-T01-A Contents Page
More informationDigitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers
Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000
More informationCP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions
CP-90 CP-90 Electronic Drives General Instructions Application The CP-90 and CP-90 electronic actuator drives process a variable input signal from a controller to provide proportional control of an electric
More informationTRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS
TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS 33220900 DECEMBER 2011 Caution: The equipment covered by these installation instructions should be installed and serviced only by properly trained
More informationI UNION SWITCH & SIGNAL llfilj
I UNION SWITCH & SIGNAL llfilj 645 Russell Street Batesburg, SC 29006 SERVICE MANUAL 3225 SL-20, SL-21, and SL-21A Electric Switch Locks Description, Installation and Maintenance Part N um hers: N241331
More informationProgressive Suspension Airtail I.A.S.
5572 Fresca Drive, La Palma, CA 90623 714.523.8700, FAX 714.523.3220 Progressive Suspension Airtail I.A.S. Installation Instructions for Harley Davidson E.C.C. with Compressor Kit FLH/FLT Models with and
More informationINSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere
. L. 41-793 NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE CRN REVERSE POWER RELAY FOR MARNE SERVCE CAUTON Before putting relays into service remove all blocking which may have been inserted for the purpose
More informationPP-151. Service Manual 4551 G. An Ansaldo Signal Company. IUNION SWITCH & SIGNALl[fil] Magnetic Stick DC Plug-In Relay
IUNION SWITCH & SIGNALl[fil] 645 Russell Street Batesburg, SC 29006 Service Manual 4551 G PP-151 Magnetic Stick DC Plug-In Relay October, 1980 D-79-100-2306-5 1980, Union Switch & Signal Inc. Printed in
More informationA AMM - KRUEGER FLAP ACTUATOR - REMOVAL/INSTALLATION
FED ALL WARNING : 1. Equipment and Materials KRUEGER FLAP ACTUATOR - LANDING GEAR - MAKE SURE THAT THE GROUND SAFETIES AND CHOCKS ARE IN POSITION. FLIGHT CONTROLS - MAKE SURE THAT THE GROUND SAFETIES AND
More informationTWIN HALOGEN SHOP LIGHT
TWIN HALOGEN SHOP LIGHT 36787 ASSEMBLY & OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web Site at www.harborfreight.com Copyright 2005 by Harbor Freight Tools. All rights
More information"N-1-A" REDUCING VALVE, Part No with "N" REDUCING VALVE PORTION, Part No
"N-1-A" REDUCING VALVE, Part No. 528348 with "N" REDUCING VALVE PORTION, Part No. 529445 DECEMBER, 1984 NOTE: The following description and operation is based on this device and its components being new
More informationWELDING FUME EXHAUSTERS & ARMS
WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through
More informationSome service parts may not be available for this product!
-00 thru -00 Power Examination Table Service and Parts Manual Serial Number Prefixes: FA, FB NO LONGER IN PRODUCTION Some service parts may not be available for this product! -00 thru -00 FOR USE BY MIDMARK
More informationService and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.
thru 391-001 -002 Otolaryngology Chair Serial Number Prefixes: EN, PD & V Service and Parts Manual NO LONGER IN PRODUCTION Some service parts may not be available for this product. 391-001 thru -002 NOTE:
More informationXPS-ProFeed Shuttle SERVICE MANUAL. Revised:
XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY
More informationD-Series Blowers and Exhausters
Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC
More informationInstallation Instructions Alternators 8LHA Series
Installation Instructions lternators 8LH Series General Information Heavy duty, all electronic alternator systems in this series are designed for use with many combinations of system voltage and grounding.
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationNational AirParts, Inc. N400 Belt Drive Alternator
National AirParts, Inc. N400 Belt Drive Alternator Basic Inspection Procedures & Tests National AirParts, Inc. 1140 AirPort Terminal Drive DeLand, FL 32724 Phone: (386) 734-3365 FAX: (386) 734-8552 National
More informationwww. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers
Instructions for Load Break Air Switch, Type LBF, for Power Centers The Westinghouse Type LB 1 F Switch is an air insulated, gang operated, three pole, two position link type load interrupter switch. The
More informationMC2500. Installation and Operation Manual
MC2500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to
More informationPT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT *****************
SERVICE MANUAL 4 5 7 8 PT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT ***************** This service specification provides information required for repair and adjustment of PT-150 thermal
More informationDrying Tumblers 120 Pound Capacity Refer to Page 3 for Model Numbers Cover
HIGH LOAD READY MEDIUM TEMPERATURE LOW LOW AIR FLOW NON REV REV PUSH TO START 0 5 5 0 50 40 60 0 30 0 0 Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Cover Parts COOLING DRYING T0C
More informationMICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL
MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS 4.0 BASIC
More informationMODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS
MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS Model 2001 HERMETI-CHECK tests all single phase compressors up to 5 HP, 110, 220, or 277 volts. The HERMETI-CHECK comes equipped with a built in 200 micro
More informationAV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions
AV-497 Valve Linkage for MK-6811 and MK-6911 General Instructions Application The AV-497 valve linkage kit is used to field assemble MK-6811 actuators onto 2-1/2 to 5 VB-8xxx series valves and MK-6911
More informationClutch Installation Guide
Clutch Installation Guide 0 STOP! READ CAREFULLY BEFORE INSTALLING CLUTCH This clutch must be installed by a qualified installer. Improper installation or failure to replace or resurface the flywheel,
More informationFitting Instructions: Sprint ST (955i), Sprint RS & Tiger 955cc Heated Grip Kit
Fitting Instructions: Sprint ST (955i), Sprint RS & Tiger 955cc Heated Grip Kit This accessory kit is designed for use on Triumph Sprint ST (955i), Sprint RS & Tiger 955cc motorcycles only and should not
More informationUser s Manual D-Series Blowers and Exhausters
User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1
More informationSERVICE BULLETIN DATE: October 29, 2004 Supersedes: S.B. 483AR6 dated 6/21/2004
NO: 483AR7 SERVICE BULLETIN DATE: October 29, 2004 Supersedes: S.B. 483AR6 dated 6/21/2004 LIMITED DISTRIBUTION SISU DIESEL LIMITED DISTRIBUTION PUMP MODELS AFFECTED: DB4629-5711 and DB4629-5712 SUBJECT:
More informationrn UNION SWITCH & SIGNAL INC.
. ~ SERVICE MANUAL 4551~K PN-lSOBC :D :C BIASED PLUG-IN DECODING RELAYS ~. (HAVING PART NUMBER SUFFIXES LESS THAN "-100") ************~************** This service specification supplements Service Specification
More informationOPERATOR S MANUAL 7(5 & ( 8&. $5.00 P/N REV.B
OPERATOR S MANUAL &281 2817( 7(5 %$/$1&( /,)7 7758& 8&. $5.00 P/N 901345 REV.B As a lift truck operator, you are responsible for a machine that is useful, powerful, and can be hazardous if not operated
More informationModel Due to continuing improvements, actual product may differ slightly from the product described herein.
12 volt Oooga horn Model 96291 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,
More informationSERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. 18 Volt Sawzall STARTING SERIAL NO. Spindle (38) to be assembled
Pull Brush Tubes () back before removing or installing the Armature (21) to protect commutator. SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 18 Volt Sawzall CATALOG NO. 2620-20
More informationTYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View
41-503.21A TYPE KF Front View Rear View Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) 2 TYPE KF 41-503.21A lower pin bearing, which is mounted on the frame, with respect to the
More informationMICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL
MICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS
More informationDry Type Distribution Transformers
Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.
More informationMAINTENANCE NOTICE. YM-2000 Switch Machine Motor Cutout Switch Adjustment. (US&S Part No. N , N , N )
Union Switch & Signal Inc., an Ansaldo Signal company 1000 Technology Drive, Pittsburgh, PA 15219 ÃÃÃ5XVVHOOÃ6WUHHWÃBatesburg, SC 29006 MN-02-001 MAINTENANCE NOTICE YM-2000 Switch Machine (US&S Part No.
More informationSECTION Transaxle, Automatic-External Controls
07-05- 1 Transaxle, Automatic-External Controls 07-05- 1 SECTION 07-05 Transaxle, Automatic-External Controls SUBJECT PAGE SUBJECT PAGE ADJUSTMENTS REMOVAL AND INSTALLATION Shift Control Cale... 0705-12
More informationth Street, Surrey, B.C. Canada V3W 0A6 Telephone Fax July 2012
8238-129 th Street, Surrey, B.C. Canada V3W 0A6 Telephone 604-572-3935 Fax 604-590-8313 http://www.kobelt.com 7173-KAS MANUAL July 2012 Leaders in Quality Marine Controls, Steering Gear, and Disc Brakes.
More information1000 Technology Drive, Pittsburgh, PA Russell Street, Batesburg, SC Plug-In Replacement for the PF256 Flasher Relay
SM 9080 1000 Technology Drive, Pittsburgh, PA 15219 645 Russell Street, Batesburg, SC 29006, PN-250F Relay Plug-In Replacement for the PF256 Flasher Relay STS USA Part No. N40116101 Installation Operation
More information50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET
R 50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET Transfer Relay Delay 00-00803-400 Dual Input Genset INDUSTRIAL CONTROL EQUIPMENT TYPE 1 Shore Power Rating: 120/240VAC 60HZ 1 Phase 50A/Pole Generator
More informationL. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)
Figure 1: Types CA-16 Relay (front view) Photo Figure 2: Types CA-16 Relay (rear view) Photo 2 Sub 5 185A419 Sub 6 185A443 Figure 3: Internal Schematic of the Type CA-16 bus Relay or CA-26 Transformer
More informationMAINTENANCE CHECKLIST RSS-2000 ELECTRIC VEHICLE BARRIER
MAINTENANCE CHECKLIST RSS-2000 ELECTRIC VEHICLE BARRIER RSSI Barriers, LLC 6530 East Highway 22 Panama City, Florida 32404 850-871-9300/Fax 850-871-4300 Web Site: www.rssibarriers.com The information contained
More informationSTYLE PN-59 SLOW PICK-UP PLUG IN D.C. NEUTRAL RELAYS FOR CODED CAB SIGNAL EQUIPMENT. WABCO PART NUMBERS N436928, N and N
SERVICE MANUAL 5624-C STYLE PN-59 SLOW PICK-UP PLUG IN D.C. NEUTRAL RELAYS FOR CODED CAB SIGNAL EQUIPMENT WABCO PART NUMBERS N436928, N436928-001 and N451130-0301 * * * * * * * * * * * * CONTENTS SECTION
More informationREAD THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments
READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood
More informationDrying Tumblers 110 Pound Capacity Refer to Page 3 for Model Numbers. Parts
Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Parts Part No. M444R April 000 Table of Contents Title Page Parts Ordering Information... Nameplate Location... Model Identification...
More informationABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet Effective: October 1999 Supersedes I.L. 41-133R, Dated August 1998 ( ) Denotes Changed Since
More informationwww. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers
i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2
More informationIDEAL Stripmaster Model 950 Wire Stripper #45-950
IDEAL Stripmaster Model 950 Wire Stripper #45-950 IDEAL Stripmaster Model 950 Wire Stripper Introduction The IDEAL Stripmaster Model 950 Wire Stripper is an electrically operated, pneumatic precision production
More informationINSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS
g INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS Manual Part Number: GEI-83964H Copyright 2000 215 Anderson Avenue Markham, Ontario L6E 1B3 Canada Telephone: (905)
More informationINSTRUCTION INFORMATION FOR TYPE "DB" ELECTRIC DISC BRAKE (DB-0, DB-2, DB-4)
The Last Word in Cranes INSTRUCTION INFORMATION FOR TYPE "DB" ELECTRIC DISC BRAKE (DB-0, DB-2, DB-4) OPERATION Zenar's type "DB" brakes are classified as a holding or parking type electro-mechanical operated
More informationNSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL
APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury
More informationBASIC TROUBLE SHOOTING (PERFECTPASS FOR MECHANICAL ENGINES) How PerfectPass Works
BASIC TROUBLE SHOOTING (PERFECTPASS FOR MECHANICAL ENGINES) How PerfectPass Works Through the in-dash display the driver sets the desired boat speed or engine RPM depending upon which mode of operation
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More information- ~SERVICE SPECIFICATION SU-4549 ~
,i -' WRBCC - SERVICE SPECIFICATION SU-4549 STYLE PL-59 RELAY GROUPS FOR AUTOMATIC TRAIN CONTROL ***************** This specification covers shop adjustment and testing of the Style PL-59 Relay Groups
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationREAD THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments
READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood
More informationPackaging Information Reels
PERFORMANCE PIPE REELS PRUCTS Size Nominal Maximum Conduit Length Reel Hub Reel Width Outside Maximum Reels Per Truck Potential Feet Per Truck Trailer Requirement 1 1.315 15,000 96 30 48 12 180,000 48
More informationService Instructions. Syntron Heavy Duty Electromagnetic Vibratory Feeders Models: F-22, FH-22, and F-88
Service Instructions Syntron Heavy Duty Electromagnetic Vibratory Feeders Models: F-22, FH-22, and F-88 Service Instructions Syntron Heavy Duty Electromagnetic Vibrating Feeders Model: F-22, FH-22, and
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More informationFLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL
FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL 82 S0150 01 REV. 1 April, 2002 TABLE OF CONTENTS PAGE # OPERATIONS MANUAL... 1 1. SYSTEM DESCRIPTION... 1 1.1 MAJOR COMPONENTS... 1 2. HOW TO OPERATE
More informationExample Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.
IRRIGATION TRAINING & RESEARCH CENTER California Polytechnic State University San Luis Obispo, CA 93407-0730 Phone: 805.756.2434 FAX: 805.756.2433 www.itrc.org Example Maintenance Schedule 1 The attached
More information