OVAL TURBO STEAM METER. 200 million times Pulse unit. 1kg/P 10kg/P 10kg/P 100kg/P Electric conduit Cable Transmission distance Pressure compensation
|
|
- Merilyn Doyle
- 5 years ago
- Views:
Transcription
1 Saturated steam Turbine flowmeter OVAL TURBO STEAM METER MiniGSM StandardGSH, GSV GENERAL SPECIFICATION GS.No.GBT301E-1 GENERAL This Turbo Steam Meter is specifically designed and built for making measurements of flow consumed at the end of steam line and is capable of indicating the total consumption over a wide range of saturated steam directly in kilogram units. When coupled to a pulse generator, it also makes remote total count obtainable. In view of today, s increasing steam cost, this instrument will contribute to attaining significant energy saving through reasonable measurement management. type type Horizontal mount Horizontal mount type Vertical mount FEATURES 1. Wide flow range and high measuring accuracy. 2. By exchanging the flow diverter nozzle, flow range can be changed without removing the meter from pipe line. 3. Meter counter can be seen locally, and output signal for remote totalization is available too. 4. Manual pressure adjusting device or Automatic Pressure Compensator (APC) is optionally available for actual readout. 5. Robust and simple configuration makes the maintenance easier. GENERAL SPECIFICATIONS Item Applicable fluid Type Nominal size Flow range Connection flange Max. operating temp. Operating pressure range Accuracy Material Display digit Counter Min. digit unit reading One pointer revolution Min. reading Type Description Saturated steam Mini (GSM) Standard (GSH, GSV) 25mm1 50mm2 80mm3 100mm4 See flow range table on page 2 JIS 10K FF 220C (Counter: 60C) 0.03 to 0.98MPa 0.05 to 0.98MPa Within2% of RD Within 2% of RD or within -4% to +2% of RD 1 BodyFC250 5-digit 10kg 100kg 100kg 1000kg 10kg 100kg 100kg 1000kg 0.5kg 2kg 2kg 20kg Contact pulse Output Contact capacity 5VA Duration 200 million times Pulse unit 1kg/P 10kg/P 10kg/P 100kg/P Electric conduit Cable Transmission distance Pressure compensation G1/2female 2-conductor CVV or CVS; conductive area: 1.25 to 2.0m 2 1km longest (with conductive area 2.0m 2 ) Manual adjusting device or Automatic Pressure Compensator (APC) 2 3 Compensation APC 0 to 0.98MPa (4 sections) 4 range Manual 0.03 to 0.98MPa Flow direction Mounting orientation Pressure loss RL (std.), LR Horizontal GSHRL, LR GSHHorizontal See page 3 GSVBottomTop GSVVertical Configuration Finish color Weight 21kg approx. Non-explosionproof; non-waterproof BodyMunsell 10Y8.5/1 Silicone resin paint See page 4 1See flow range table for the details. 2Should inductive interferences be expected, use a vinyl sheathed isolation cable (CVVS) which can shut off electrostatic energy. 3In case longer than 1km, consult OVAL. 4See page 2 for the detail of the sections. OVAL Corporation Head Office (Tokyo): Tel Fax Beijing Office: Tel Fax Overseas Branch Offices: Seoul, Singapore and Taipei
2 FLOW RANGE Min TypeGSM Unit in kg/h Steam pressure No. of diverter nozzle MPagauge to to to to to 53 8 to to to 60 9 to to to to to to to to to to to to to to to to to to to to to to to to to to to to 67 With the built-in flow diverter nozzle, flow range of Mini type can be changed. Table left shows the flow range per each diverter nozzle to each pressure of saturated steam. All of the diver No. 1, 2 and 3 are provided together with meter. No. 1 is in the meter when delivered, and needs to be replaced with another depending on the required flow range. Standard TypeGSH, GSV Flow range of standard type (GSH, GSV) can be changed depending on the orifice-plate inserted in the main pipe of meter body even with same nominal size. Table below shows the flow range per each orifice plate to each pressure of saturated steam. Nom. size 50mm2 80mm3 100mm4 No.1 No.2 No.3 No.1 No.2 No.3 No.1 No.2 No.3 Steam Pres. MPa Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max Accuracy should be within 2% of RD in from 1.5 times of min. flow rate to max. flow rate; within -4% to +2% in from min. flow rate to 1.5 times of min. flow rate. Instantaneously flowing 1.2 times of max. flow rate would not cause abrasion damages. Use orifice plate of proper No. so as to be 70% of max. flow rate as its nominal flow rate. Upon your advice of required flow rate, orifice with proper No. is furnished on the meter when delivered. Other No. orifice plates are not provided. Orifice No. Service Condition MODEL CODE NUMBER Min TypeGSM Code No. Item Description Model G S OVAL TURBO STEAM METER Installation M Horizontal mountmin type Nominal size mm1 0 Always 0 Material B FC250 1 Direct coupled counter Readout A Direct coupled counter with pulse generator M Manual adjusting divice Pres. Compensation P Automatic Press. Compensator 0 None 1 0 to 0.22MPa Range of APC to 0.51MPa to 0.83MPa to 0.98MPa Standard TypeGSH, GSV Item Model G S Code No. Description OVAL TURBO STEAM METER Installation H Horizontal mount V Vertical mount mm2 Nominal size mm mm4 1 No.1 Orifice Plate 2 No.2 3 No.3 Material of Meter Body B FC250 Read out 1 Direct coupled counter A Direct coupled counter with pulse generator M Manual adjusting device Pres. Compensation P Automatic Press. Compensator 0 None 1 0 to 0.22MPa Range of APC to 0.51MPa to 0.83MPa to 0.98MPa
3 PERFORMANCE CHARACTERISTICS Min TypeGSM Meter Error Pressure Loss Data in the condition of 0.49MPa saturated steam is shown. 100% flow rate shows the maximum flow rate at respective diverter nozzles. Standard Type Meter Error Pressure Loss Data in the condition of 0.49MPa saturated steam is shown. 100% flow rate shows the maximum flow rate at respective diverter nozzles. DIMENSIONSUnit in mm Min TypeGSM Manual Pressure Adjustment Version Automatic Pressure Compensation Varsion
4 DIMENSIONSUnit in mm HORIZONTAL MOUNT TYPEH TYPE Manual Pressure Adjustment Version VERTICAL MOUNT TYPEV TYPE Manual Pressure Adjustment Version Automatic Pressure Compensation Version Automatic Pressure Compensation Version It is necessary to keep distance of more than 200mm from wall surface for replacement of orifice plate Top for water filling Drain plug Horizontal Mount Type Vertical Mount Type Model Size Flange rating L h1 h2 H a1 a2 A Operating Test Weight Pressure Pressure mm h1 h2 H kg GSH05 B GSH08 B GSH10 B GSV05 B GSV08 B GSV10 B Figures in brackets indicate APC furnished version. Max. MPa Hydraulic MPa
5 INSTALLATION Mini Type (GSM)Horizontal only Standard (GSH, GSV)Horizontal or vertical Straight pipe sections of 10D on meter upstream and 5D on downstream are required as minimum. This applies in piping with bi-pass lines also. Before starting operation, do not fail to fill up the reduction gear chamber with clean antifreeze solution, particularly, in winter time to avoid freezing. Suitable concentration of the antifreeze is described in the meter instruction manual. Typical piping layout Min TypeGSM The direction of the counter face can be changed in 90 degree steps as necessary Standard TypeGSH, GSV HORIZONTAL INSTALLATION VERTICAL INSTALLATION The direction of the counter face can be changed in 90 deg. steps as necessary.
6 TOTALIZER In case of the direct reading/remote reading type (A type), a pulse generator is installed on the meter register and can be connected with a remote totalizing counter. The totalizing counter makes 10 counts receiving a pulse signal per a revolution of the pointer in the direct coupled register. Model Total flow EL0122 Power supply EL0123 Weight EL0122, EL Digits 85 to 264 VAC 50/60Hz A built-in lithium battery Capacity3.6V 5.4 amp-hr. A connector coupled, dedicated batteryum-3 size2 "BATT" displays in case of voltage reduction Life 4 years Approx. 0.4kgEL0122, Approx. 0.2kgEL0123 1EL0123 (battery drive) does not have alarm functions. EL0123 has a function to display instantaneous flow rate, however, it is not shown with Turbo Steam Meters for their very low pulse frequencies. (Display remains to be 0.) See GS No. GED713 and 714 for the details. PLEASE SUPPLY THE FOLLOWING INFORMATION WHEN YOU INQUIRE Tick the boxes of your request and/or describe your requirements. 1 Application 2 Fluid 3 Operating conditions 1Flow range 2Fluid temp. (Not required to saturated steam) 3Fluid pressure 4 Flow direction 5 Remote totalization Saturated steam Other Min. Nor. Max. kg/h kg/h kg/h MPaG MPaG MPaG Mini TypeRL LR Std. typehorizontalrl, LR VerticalBottomTop Required Not required 6 Special note The specification as of July, 2008 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative:
OVAL TURBO STEAM METER
Steam Turbine Flowmeter for Saturated Steam OV TURBO STEM METER Mini: GSM Standard: GS, GSV GENER This Turbo Steam Meter is specifically designed and built for the measurements of saturated steam consumption
More informationFLOWMETER (SMALL CAPACITY) METER SIZE 80, 81
UF- FLOWMETER (SMALL CAPACITY) METER SIZE, GENERAL SPECIFICATION GS.No.GBL--E GENERAL The UF-II Series is a new positive displacement flowmeter developed specifically to serve as the heart in loading facilities
More informationExcellent Vortex Flowmeter INSERTION Type SMART EX DELTA
Excellent Vortex Flowmeter INSERTION Type SMART EX DELTA GENERAL SPECIFICATION GS.No.GBD603-6-E GENERAL The smart Insertion type EX DELTA has newly been developed being added the following smart functions
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationAIR MOTOR MASTER VALVE FULL OPEN POSITION SENSOR SWITCH. Overall Block Diagram (Local Control Type)
GENERAL SPECIFICATION GS.No.GCG200E3 GENERAL The V-Torq Ⅱ is a pneumatic valve actuator using a vane air motor for its drive source. Opening and closing operations of manual valves can be very labor intensive,
More informationGeneral Specifications
General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order
More informationProduct. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.
Series 7.007 Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 6 D-40595 Düsseldorf/Germany Tel.: +49(0)-79-0 Fax: +49(0)-79-8 e-mail: info@akmueller.de
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationSTUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600
STUF-280W Features: Wear-free ultrasonic measurement. No moving parts. No maintenance needed Proprietary robust sensor design. Not impacted by water impurity Counts each drop. Very low start flowrate Excellent
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationVZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser
VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationVortex Eggs Delta Flowmeter
Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationFact File 59 Extinguishing systems
Fact File 59 Extinguishing systems Foam Inductors: Guidelines on their selection, use and maintenance Foam Inductors: Guidelines on their selection, use and maintenance INTRODUCTION... 3 HOW INDUCTORS
More informationFundamental Training. Flow Con t
Fundamental Training Flow Con t 1 Contents Topics: Slide No: Velocity flow meters 3-11 Mass flow meters 12-17 Displacement meters 18 Exercise 19-20 2 Velocity Meter Magnetic Flowmeter Faraday s Law of
More informationATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6
The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/
More information/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?
Vortex Flow Monitor /OVAL Eggs DELTA Pulse OPERATION MANUAL MODEL : FLP? L A G 1 2 FLP? L? SA G 1 2 FLP? L? G 1 2 P N A Every Sparling/OVAL vortex flow monitor Eggs DELTA Pulse is fabricated and shipped
More informationTFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions
1930051/2 IM-P193-03 MI Issue 2 TFA meter for Saturated Steam Service Installation and Maintenance Instructions This guide must be read in conjunction with the Installation and Maintenance Instructions
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More information유량계전문제조업체. Electro Magnetic FLOWMETER
유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationVortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable
More informationAutoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69)
Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) A range of thermocouple sensors specifically designed to withstand the harsh conditions within autoclaves. Autoclave Load and Drain thermocouples
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationHigh Performance Turbine Technology
The Brooks Parity Turbine Meter Sizes 3" - 16" High Performance Turbine Technology Design Specifications DS2215-10 July, 1999 DESCRIPTION The Parity Turbine Flowmeter utilizes advanced turbine meter technology
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationCDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationType 441 CATALOG. Flanged Safety Relief Valves. The-Safety-Valve.com
Type 441 Flanged Safety Relief Valves CATALOG The-Safety-Valve.com General Information LESER India Safety Relief Valves The safety valve Type 441 represents High capacity related to the safety valve size
More informationFuel Consumption Measurement _ 124. Application Bulletin
Fuel Consumption Measurement _ 124 Application Bulletin WWW.VAF.NL 1 Introduction Due to the increasing awareness of the impact of exhaust emissions on the environment, combined with the continued increases
More informationThe Multivariable Air Flow Meter
No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F
More informationtprime TM Series 280T
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationDY-LWGY Liquid turbine flow meter
Typical Application: liquid with no impurities and no corrosion, such as water, diesel, methanol. DY-LWGY Liquid turbine flow meter One. Overview DY-LWGY series Turbine Flow has its simple structure, light
More informationFUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.
FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS by John Michalak Romet International, Inc. INTRODUCTION Rotary gas meters have been in use for over sixty years in the natural gas distribution industry. Over
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationGS.No.GBN120E 9. Liquid. Gas. High Performance Coriolis Flowmeters GENERAL
iquid Gas High Performance Coriolis Flowmeters GENERA SPECIFICATION GS.No.GBN120E 9 arge sized type ow temperature explosionproof service type High temperature service type Extra low flow type ow flow
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationMASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter
MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.
More informationRIM20 Rotor Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationThe Multivariable Air Flow Meter
The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-
More information25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS
TS- Rev. B Type S lowmeters 1, 1 1 2 & 2 mm (1 in), mm (1-1/2 in) & mm (2 in) TYPE S LOWMETERS WITH MODEL 7 AND 8 SERIES REGISTERS 1-1/2" Type S with Model 7 Register SPECIICATIONS 1" Type S with Model
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring
More information4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304
VORTEX FLOW METER Vortex Flowmeter Advantages: Integrated pressure and temperature compensation. 4-20mA, pulse with HART or pulse with RS485 are selectable. Wide temperature range up to highest temperature
More informationProduct Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date
FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced
More informationI-BFV.KIT Butterfly Valve Gear Operator Replacement
SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before
More informationDifferential pressure gauge with reed switch Model: P680 series
Differential pressure gauge with reed switch Model: P680 series Spec. sheet no. PD06-10 Service intended P680 series are differential pressure gauge is designed to measure differential pressure from 25
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationEZ-IN Series Turbine Flowmeter
Class I, Group A, B, C, D, Division I Complies with ASME Standard B31.3 NUFLO EZ-IN Series Turbine Flowmeter Installation Manual Part No. 9A-100062997, Rev. 01 Measurement Systems EZ-IN Series BF Turbine
More informationTop-Guided Single Seated Control Valves (Rating : ANSI 600 or Less)
No. SS2-8-0 Top-Guided Single Seated Control Valves (Rating : ANSI 0 or Less) OVERVIEW Model VST control valves are suitable for use in fluid with slurry because of its one side guiding construction. Guide
More informationLEAD FREE * LFF113RFP Flood Protection Shut Down Valve
Technical Bulletin TB-ACV-LFF11RFP LEAD FREE * LFF11RFP Flood Protection Shut Down Valve Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when continuous discharge from
More informationFlow Controller, flow control system for gases
Flow Controller, flow control system for gases Highly cost effective solution, thanks to the integrated system Reliable, robust system Automatic process tune Simple to operate Type 8750 can be combined
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationMeasurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide
Measurement Products Measurement made easy Swirl flowmeters FS4000 Simply fitting your purpose Application guide Swirl flowmeters Serving your application Exceeding your expectations about modern field
More informationLiquid Turbine Flowmeter
NUFLO Liquid Turbine Flowmeter User Manual 167018 Explosion-proof for use in Class I, Division I, Groups A, B, C, D Hazardous Environments ANSI 12.27.01-2003 Single Seal Part No. 9A-100062201, Rev. 01
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationTime Delta S Fixed Transit-Time Flow Meter System
Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The
More informationOil Meter HZ 3 and HZ 3 RR Mounting Instructions
Oil Meter HZ 3 and HZ 3 RR Mounting Instructions Scope of supply 1. HZ 3 oil meter or HZ 3 RR oil meter 2. Lip sealing ring (2 off) 3. Clamps (3 off) 4. Mounting plate 5. Mounting instructions Safety advice
More informationVariable Area Flowmeters Ori-Flowrator TM Meters
Data Sheet (US) Variable Area Flowmeters Ori-Flowrator TM Meters 10B4000 Low installation cost Linear indication over 12-1/2 to 1 flow range Inexpensive method of measuring large flow rates in direct flow
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationSpecialties in Steam Flow Measurement
Specialties in Steam Flow Measurement Flow Measurement in: Wet Steam: Only with severe limitations Water content cannot be measured from pressure and temperature because: Water content x is NO function
More informationPositive Displacement Flowmeters GM020 series instruction manual
ACCURATE FLOWMETERS & INSTRUMENTATION PVT. LTD. Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX Accurate Flowmeters & Instrumentation Pvt. Ltd.
More informationLC OVAL GEAR FLOWMETER
LC OVAL GEAR FLOWMETER DN10-DN25 DN50-DN100 Digital Register DN65 High Temp. DN150,DN200 DN50-DN100 General Description Oval gear flowmeters are instruments used for the continuous and intermittent measurement
More informationA6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM
Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector
More informationT-Sense. Optical Torque Measuring systems. Product Bulletin TO BE REALLY SURE
TSense Optical Torque Measuring systems 660 Product Bulletin WWW.VAF.NL TO BE REALLY SURE 1 Introduction Principle of operation The use of a TSense torque measuring system means efficiency improvement,
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL MODEL T575N TEMPERATURE COMPENSATED TOTALIZER/PRINTER DOC#: MN-T575N SPONSLER, INC. Liquid and Gas Flow Measuring Devices and Controls LBS ON OFF TRUCK TOTALIZER MODEL T575N
More informationKRAL Volumeter - Turbine Fuel and Water Injection Measurement
KRAL Volumeter - Turbine Fuel and Water Injection Measurement Fuel Consumption Measurement for Turbines Accurate, reliable and leakage-free fuel consumption measurement, is now possible. Fuel Cost Reduction
More informationMODEL 422 Submersible Pump Controller
MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and
More informationFlow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)
IOM IR-472-50-bRU Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300) Description: The BERMAD Flow Control and Pressure Reducing Valve with Hydraulic Control is a
More informationHelical Flow. HF-GC/GP Series
Helical Flow A Helical Flow Type of Screw Revolution Instruction Manual for HF-GC/GP Series (SC and MP/MC Series incld. ) Caution Before use, please read this Instruction Manual thoroughly for safe operation.
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationSmart Electromagnetic Flowmeter Detector for Sanitary use
MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable
More informationManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:
KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s
More informationElectro-Magnetic Flowmeters Sensors MagMaster MFE
Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationVariable Area Flowmeter BROCHURE
Variable Area Flowmeter BROCHURE JUNHO 2013 Measurement Products Variable area flowmeters Reliable, flexible, simple and cost effective Variable area flowmeters Reliable, flexible, simple and cost effective
More informationDevelopment of Low-thrust Thruster with World's Highest Performance Contributing to Life Extension of Artificial Satellites
Development of Low-thrust Thruster with World's Highest Performance Contributing to Life Extension of Artificial Satellites 40 NOBUHIKO TANAKA *1 DAIJIRO SHIRAIWA *1 TAKAO KANEKO *2 KATSUMI FURUKAWA *3
More informationTEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW
Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also
More informationLiquid Turbine Flowmeters
NUFLO Liquid Turbine Flowmeters Accurate Flow Measurement In 1957, this flowmeter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of the oil field. Over the years,
More informationBYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES
BULLETIN 20-5100-68 BYPASS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BYPASS ROTOMETERS SK bypass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 11/2
More informationNO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor
Precise programmable control of liquid flow rate from 0.5 5, 1 10 or 2 20 L/min Useable to 60 C, 60 psi Integrated axial-flow turbine flowmeter Fast, responsive PID controller rotates vane to maintain
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More information