Global Finishing Solutions Table of Contents
|
|
- Shana Weaver
- 5 years ago
- Views:
Transcription
1 Global Finishing Solutions Table of Contents Spray Booths-Accessories ProClean - Open Face Filter Booths... 2 ProClean Extensions... 3 Redi-Pak TM - Bench Booths... 4 Ultra and Concept Paint Mix Rooms... 5 Truck/Heavy Duty Spray Booths... 6 Exhaust Stack Exhaust Stack Accessories... 9 Floor & Wall Covering... 10
2 Spray Booths-Accessories ProClean TM - Open Face Filter Booth Complete with... Class I Division, 2 fluorescent 4-tube lighting fixture(s)* (tubes not included) High efficiency exhaust fan(s) TEFC type, 3 phase multi-voltage ( /460/60 Hz/3 PH and 575/60/30) electric exhaust fan motor. Available in 17 1/2, 24, 34 and 40 diameters. Mount in horizontal or vertical stacks One complete set of filter media. Your choice of filtration media, pads or rolls Manometer (draft gauge) Top or rear exhaust outlet * For specific number of light fixtures, fan quantity and cutting diameter, consult specifications chart. Work Depths Overall Dimensions CFM Booth Height Width Depth Height Width Depth # of Light Fan Fan # Motor Required Delivery (Ft.) (Ft.) (Ft.) (Ft.) (Ft.) (Ft.) Fixtures Dia. 100 FPM HP 100 s.p. TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA TBI FA
3 ProClean TM Extensions Working Compartment Extensions Working compartment extensions are specifically designed to increase the working compartment depth of ProClean TM dry filter spray booths. Same 18 gauge galvanized panel construction as booth Available widths - 3 with or without Class I Div. 2 light fixture(s), all models; - 2 no lights, for booths up to 12 wide; - 6 with or without Class I Div. 2 light fixture(s), for booths wide Lights are UL and CSA approved. Tubes not included. Spray Booths-Accessories 6 Wide 8 Wide 10 Wide 12 Wide Extension Number Extension Number Extension Number Part Number Dimensions Of Lights Part Number Dimensions Of Lights Part Number Dimensions Of Lights TBIE-673-SLD 7 H-3 W No lights TBIE-1473-SLD 7 H-3 W No lights TBIE-1873-SLD 7 H-3 W No lights TBIE-673-LIGHT 7 H-3 W 1 light TBIE-1473-LIGHT 7 H-3 W 2 lights TBIE-1873-LIGHT 7 H-3 W 2 lights TBIE-672-SLD 7 H-2 W No lights TBIE-1476-SLD 7 H-3 W No lights TBIE-1876-SLD 7 H-6 W No Lights TBIE-683-SLD 8 H-3 W No lights TBIE-1476-LIGHT 7 H-6 W 2 lights TBIE-1876-LIGHT 7 H-6 W 2 lights TBIE-683-LIGHT 8 H-3 W 1 light TBIE-1483-SLD 8 H-3 W No lights TBIE-1883-SLD 8 H-3 W No lights TBIE-682-SLD 8 H-2 W No lights TBIE-1483-LIGHT 8 H-3 W 2 lights TBIE-1883-LIGHT 8 H-3 W 2 lights TBIE-6103-SLD 10 H-3 W No lights TBIE-1486-SLD 8 H-6 W No lights TBIE-1886-SLD 8 H-6 W No lights TBIE-6103-LIGHT 10 H-3 W 1 light TBIE-1486-LIGHT 8 H-6 W 2 lights TBIE-1886-LIGHT 8 H-6 W 2 lights TBIE-6102-SLD 10 H-2 W No lights TBIE SLD 10 H-3 W No lights TBIE SLD 10 H-3 W No lights TBIE-6123-SLD 12 H-3 W No lights TBIE LIGHT 10 H-3 W 2 lights TBIE LIGHT 10 H-3 W 2 lights TBIE-6123-LIGHT 12 H-3 W 1 light TBIE SLD 10 H-6 W No lights TBIE SLD 10 H-6 W No lights TBIE-6122-SLD 12 H-2 W No lights TBIE LIGHT 10 H-6 W 2 lights TBIE LIGHT 10 H-6 W 2 lights TBIE-873-SLD 7 H-3 W No lights TBIE SLD 12 H-3 W No lights TBIE SLD 12 H-3 W No lights TBIE-873-LIGHT 7 H-3 W 1 light TBIE LIGHT 12 H-3 W 2 lights TBIE LIGHT 12 H-3 W 2 lights TBIE-872-SLD 7 H-2 W No lights TBIE SLD 12 H-6 W No lights TBIE SLD 12 H-6 W No lights TBIE-883-SLD 8 H-3 W No lights TBIE LIGHT 12 H-6 W 2 lights TBIE LIGHT 12 H-6 W 2 lights TBIE-883-LIGHT 8 H-3 W 1 light TBIE-1673-SLD 7 H-3 W No lights TBIE-2073-SLD 7 H-3 W No lights TBIE-882-SLD 8 H-2 W No lights TBIE-1673-LIGHT 7 H-3 W 2 lights TBIE-2073-LIGHT 7 H-3 W 4 lights TBIE-8103-SLD 10 H-3 W No lights TBIE-1676-SLD 7 H-6 W No lights TBIE-2076-SLD 7 H-6 W No lights TBIE-8103-LIGHT 10 H-3 W 1 light TBIE-1676-LIGHT 7 H-6 W 2 lights TBIE-2076-LIGHT 7 H-6 W 4 lights TBIE-8102-SLD 10 H-2 W No lights TBIE-1683-SLD 8 H-3 W No lights TBIE-2083-SLD 8 H-3 W No lights TBIE-8123-SLD 12 H-3 W No lights TBIE-1683-LIGHT 8 H-3 W 2 lights TBIE-2083-LIGHT 8 H-3 W 4 lights TBIE-8123-LIGHT 12 H-3 W 1 light TBIE-1686-SLD 8 H-6 W No lights TBIE-2086-SLD 8 H-6 W No lights TBIE-8122-SLD 12 H-2 W No lights TBIE-1686-LIGHT 8 H-6 W 2 lights TBIE-2086-LIGHT 8 H-6 W 4 lights TBIE-1076-SLD 7 H-3 W No lights TBIE SLD 10 H-3 W No lights TBIE SLD 10 H-3 W No lights TBIE-1073-LIGHT 7 H-3 W 2 lights TBIE LIGHT 10 H-3 W 2 lights TBIE LIGHT 10 H-3 W 4 lights TBIE-1072-SLD 7 H-2 W No lights TBIE SLD 10 H-6 W No lights TBIE SLD 10 H-6 W No lights TBIE-1083-SLD 8 H-3 W No lights TBIE LIGHT 10 H-6 W 2 lights TBIE LIGHT 10 H-6 W 4 lights TBIE-1083-LIGHT 8 H-3 W 2 lights TBIE SLD 12 H-3 2 No lights TBIE SLD 12 H-3 W No lights TBIE-1082-SLD 8 H-2 W No lights TBIE LIGHT 12 H-3 W 2 lights TBIE LIGHT 12 H-3 W 4 lights TBIE SLD 10 H-3 W No lights TBIE SLD 12 H-6 W No lights TBIE SLD 12 H-6 W No lights TBIE LIGHT10 H-3 W 2 lights TBIE LIGHT 12 H-6 W 2 lights TBIE LIGHT 12 H-6 W 4 lights TBIE SLD 10 H-2 W No lights TBIE SLD 12 H-3 W No lights TBIE LIGHT12 H-3 W 2 lights TBIE SLD 12 H-2 W No lights TBIE-1273-SLD 7 H-3 W No lights TBIE-1273-LIGHT 7 H-3 W 2 lights TBIE-1272-SLD 7 H-2 W No lights TBIE-1283-SLD 8 H-3 W No lights TBIE-1283-LIGHT 8 H-3 W 2 lights TBIE-1282-SLD 8 H-2 W No lights TBIE SLD 10 H-3 W No lights TBIE LIGHT10 H-3 W 2 lights TBIE SLD 10 H-2 W No lights TBIE SLD 12 H-3 W No lights TBIE LIGHT12 H-3 W 2 lights TBIE SLD 12 H-2 W No lights 14 Wide 6 Wide 20 Wide 18 Wide 85
4 Spray Booths-Accessories Redi-Pak TM Bench Booths Bench Dry Filter Spray Booths Bench Booths are supplied complete with... High efficiency exhaust fan TEFC type, 3 phase multi-voltage ( /460/60 Hz/3 PH and 575/60/3) electric exhaust fan motor One complete set of filter media Manometer (draft gauge) Top or rear exhaust outlet Class 1, Division 2 four-tube fluorescent light fixtures (tubes included) Standard with 5 0 and 7 6 wide models. Best quality lighting air flow value Ideal for spraying small products Easy assembly All models provide minimum 100 FPM Top and rear panels are interchangeable allowing top or rear exhaust Easy Assembly This booth s tought 18-gauge G-90 galvanized, CNC punched panels are designed for fast, easy assembly, while creating a strong, rigid structure. High quality assembly hardware and illustrated assembly instructions are included. Work Depths Overall Dimensions No. of Light Fan Dia. Fan Number Motor CFM Height Width Depth Height Width Depth Fixtures HP Delivery Booth (ft.) (ft.) (ft.) (ft.) (ft.) s.p TBI-3BT /2 FA / TBI /2 FA / TBI /2 FA TBI FA Control Packages Allows you to orer one number and receive all the necessary electrical controls for a specific size booth. Each kit includes - 1 each fused disconnect with fuses - 1 each magnetic motor starter with overload heater and 120V control coil - 1 each 1/2 solenoid for safety interlock (120V) - 1 each light switch 120V or 277V - 1 each push button motor starter 1/2 HP Motor 208/60/3 CP /2 HP Motor 230/60/3 CP /2 HP Motor 460/60/3 CP /2 HP Motor 120/60/1 CP /2 HP Motor 230/60/1 CP HP Motor 208/60/3 CP HP Motor 230/60/3 CP HP Motor 460/60/3 CP HP Motor 120/60/1 CP HP Motor 230/60/1 CP Exhaust Stack Kits. Team Blowtherm offers a full line of engineered spray booth exhaust stqack and ducting products. Standard stack kit packages are available for most applications. Each stack kit includes 3-2 long pieces of plain stack, a stack head, 1-3 piece of universal stack with clean-out door. Stacks are sufficient for a maximum outsidde roof height of 15 with a minimum of 6 of duct extending above roof. Additional stack components can be ordered separately. Order: 17 1/2 Diameter Stack - KK-1700N 24 Dia.Stack -- KK-2400N 86
5 Ultra and Concept Paint Mix Rooms Spray Booths-Accessories Mix Room Specifications Pressurized downdraft airflow for ideal ventilation Ultra TM dual skin insulated panel construction or Concept TM four-sided rolled edge single skin panel construction Multiple standard sizes Maximum external height is 11 0 White precoated galvanized steel Pressurized blower with 1/2 HP motor Auxiliary exhaust blower; standard with Ultra TM model (optional with Concept TM model) High efficiency ceiling filter 4-tube light fixture(s) with color corrected T-8 tubes (quantity based on mix room size) (1) Personnel access door with observation window Built-in spill containment (no curb required) Mix room is designed to accept fire suppression system Two- and three-wall units are available for economical connection to dual skin booths Top perimeter facia package is standard Optional Equipment (partial listing) Vestibules Exhaust stack kit Auxiliary exhaust blower for Concept TM model Observation windows Additional access doors Fire suppression 87
6 Spray Booths-Accessories Truck/Heavy Duty Spray Booths Flexible Modular Design Multiple width, length and height combinations allows for expansion from 24 to unlimited lengths Three types of air flow systems: Downdraft, Pressurized Crossdraft and Crossdraft Quality Construction 18 gauge pre-coated and gauge structural steel components Precise tolerance engineering Wall-mounted 6-tube ETL approved Class 1 Division 2 fluorescent light fixtures for superior illumination Equipment installation by certified sales, installation and service technicians More Choices to meet your requirements Booth configurations: drive-thru, split and solid back and combinations Custom engineering for special applications Indoor and outdoor types 88
7 Exhaust Stack Spray Booths-Accessories TBI s Exhaust Air TM components are specifically designed, engineered and constructed for use with ProClean TM -style paint spray booths, and conform to NFPA 33 and NFPA 91 standards, and OSHA requirements. A full line of components is available to meet most spray booth exhaust air requirements. TBI recommends additional consideration be given to site sound level management issues. The proper spray booth exhaust ducting configuration, component selection, and relative positioning are key to quieter installations. TBI is the industry s leader in sound management technology. Exhaust Stack Kits TBI offers a full line of engineered spray booth exhaust stack and ducting products. Standard stack kit packages are available for most applications. Each stack kit includes 3-3 long pieces of plain stack, a stackhead, 1-3 piece universal stack with cleanout door, and a flat roof flange for a fireproof roof sufficient for a maximum outside roof height of 15 with a minimum of 6 of duct extending above roof. Additional stack components can be ordered separately. 17 1/2 KK KK KK KK-4000 Five Easy Ways to Order from Fluid-Air Products Inc. CALL Toll-Free to order MAIL your order Gravois Rd. St. Louis, MO FAX your order your order info@fluidair.com WEBSITE Visit our site and link to for on-line ordering 89
8 Spray Booths-Accessories Exhaust Stack (cont ) Plain Exhaust Pipe Section Straight 3 long section, with one end corrugated for easy installation. All sizes constructed from galvanized steel and require some assembly. 17 1/2 XH XH XH XH-4040 Universal Exhaust Pipe with Removable Clean Out Door Straight 3 long section, with large, easily-removed panel for inspection and cleaning of exhaust fan components. Designed to be installed directly below (or prior to ) the TBI exhaust fan. All sizes constructed from galvanized steel and require some assembly. 17 1/2 XH XH XH XH-4050 Plain Exhaust Pipe with Removable Clean Out Door Straight 3 long section, with large, easily-removed panel for inspection and cleaning inside of exhaust stack. One end is corrugated for easy installation. TBI recommends one section every 9 of exhaust stack, and prior to offsets/transitions, allowing periodic access. All sizes constructed from galvanized steel and require some assembly. 17 1/2 XH XH XH XH-4020 Elbows Half radius throat for tight applications where full throat will not fit. All sizes are constructed from galvanized steel and shipped assembled. 17 1/2 ELB ELB ELB ELB /2 XH XH XH XH-4514 Stackhead Weather-tight design provides automatic protection against rain, snow and backdrafts for the exhaust system, spray booth and operator. All sizes constructed from galvanized steel and require some assembly. 17 1/2 XH XH XH XH-4030 Muffler (Sound Attenuator) Exhaust Air TM mufflers will assist with site sound management. The units are designed to be installed between the exhaust system origination point and the exhaust fan. Each installed muffler can reduce the noise level from 2-5 db in most situations. In today s environment this is a very important consideration. All sizes constructed from galvanized steel and acoustical sound attenuation materials, and includes one fan connector ring. Shipped assembled. 17 1/2 MUF MUF MUF MUF-4063 Roof Flanges Available for fire rated and non-fire rated roofs with a maximum roof slope of 21 o in 3 o increments. Roof flanges built for nonfire proof roofs have a built-in thimble to penetrate the roof opening. Fireproof type Roof Slop 0 o Non-Fireproof type Roof Slop 0 o 17 1/2 XH XH XH XH /2 XH XH XH XH /2 AS AS AS AS-4040 Automatic Shutter For exhausting through side of building. Non-motorized louvers built into a square housing. Includes square to round transition. 90
9 Exhaust Stack Accessories Spray Booths-Accessories Fan Motor Housing Weather-tight, ventilated enclosure designed to protect the electric fan motor when installed outside. Constructed from galvanized steel and requires some assembly. 17 1/2 XH XH XH XH-4090 Stack Band Flanged steel band with holes for fastening to stack. Included are 3 eyebolts for attaching guy wire cable to vertical stack or hangers on horizontal stack sections. 17 1/2 XH XH XH XH-4255 Fan Support Frame for Flat or Pitched Roof Outdoor roof-mounted unit specifically designed to support the exhaust fan and connected exhaust stack. TBI recommends using for all outdoor roof-mounted exhaust fans. Constructed from galvanized angle iron and requires some assembly. 17 1/2 JF JH JJ FFA-400 Fan Connector Ring For connecting the exhaust fan to other exhaust system stack components. Note: Two (2) connector rings are supplied with every TBI fan assembly as standard. 17 1/2 SR SR SR SR-4005 Cable Accessory Kit 75 of 1/4 galvanized cable, anchors, turnbuckles and clamps for installation of 3 guy wires to above roof exhaust stack. Note: Order stack band separately. Stack Diameter All sizes Part Number XH
10 Spray Booths-Accessories Spray Booth Products: Floor & Wall Covering Protects Paint Spray Booth Floors and Walls from Overspray Clean Floor TM Flame Retardant Paper Durable, flame-retardant paper floor covering. Allows fast, easy booth clean-up - no scraping, stripping or scrubbing. Virtually eliminates tracking of paint from spray booth to other paint areas Reduces fire hazard potential due to accumulation of paint overspray Maximum durability even where dollies, fork lifts, or other heavy equipment is utilized BoothCoat TM Peelable Wall Coatings Peelable, non-flammable, white wall coating. Waterbased Easy on- sprays on in minutes Easy off - peels off in sheets Fast drying Reduces costly clean-ups and downtime Visibility enhancing bright white Excellent coverage per gallon For wet, dry and powder booths Flame Retardant Paper Master Corrugated Product Flame Retardant Paper Number of Paper Rolls Case Dimensions: Shipping Weight Number Roll Dimensions Per Case (Length x Width x Height) (Pounds) x x 8 x x x 8 x x x 8 x x x 8 x x x 8 x 8 75 Peelable Coatings for Paint Spray Booth Walls Booth Coat Product Booth Coat Number of Units Shipping Weight Number Product Description Per Product Number Five Gallon Pail Dimension (Pounds) Gallon Cans; Dries Clear 1 7 x 7 x Gallon Pails; Dries White 1 15 height x 39 diameter 55 92
Global Finishing Solutions Table of Contents
Global Finishing Solutions Table of Contents Spray Booths-Accessories Open Face Industrial & Fast Pak Booths... 91 Touch-Up, Bench & Small Fast Pak Booths... 92 Large Fast Pak Booths... 93-94 Booth Selection
More informationOpen Face Industrial Booths
Global Finishing Solutions Open Face Industrial Booths Expandable Modular Design > Easy Assembly > Heavy - Duty Construction > Meets or Exceeds National Code Requirements > Conveyor and Crane Openings
More informationThirteen (13) UL listed fluorescent fixtures per booth will supply illumination.
Quoted as per your request: two (2) Non-Pressurized, Drive-Thru, Full Down Draft, Paint Booth model: TDD-16-16-20-DT with interior working dimensions of 16-0 wide X 16-0 tall X 20-0 long. Overall dimensions
More informationModified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges
Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below
More informationOpen Front Booths. UL & ETL listed control panel. Air solenoid valve. 5/16" bolts with serrated lock nut. Industry-leading light levels
Open Front Booths Heavy Duty Bolted Construction Batch and Automated Production Designs Easy to Install ETL Certification Available Available in a Wide Range of Designs to Meet Any Production Requirement
More informationEngineered Products. Contact an Engineered Products team member today for your special projects.
Engineered Products Col-Met s Engineered Products Group is here to help you with your custom projects. Our highly experienced team has been selected to help our distribution partner s design and engineer
More informationINDUSTRIAL PRODUCT CATALOG
INDUSTRIAL PRODUCT CATALOG GLOBAL FINISHING SOLUTIONS I GLOBALFINISHING.COM GFS DISTRIBUTOR USE ONLY TABLE OF CONTENTS About GFS...3-4 Selecting a Booth... 5 Open Face Booths...6-12 Exhaust & Intake Chambers...
More informationTruck and Large Equipment
GLOBAL FINISHING SOLUTIONS Truck and Large Equipment Galvanized Spray Booths Heavy-Duty Construction Inside-Accessible, Energy Efficient Light Fixtures and - Models Expandable Modular Designs www.globalfinishing.com
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationNON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP
Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationPowder Booths. Non-Recovery Booths Cartridge Style Booths High Production Booths GLOBAL FINISHING SOLUTIONS.
GLOBAL FINISHING SOLUTIONS GLOBAL FINISHING SOLUTIONS Powder Booths Non-Recovery Booths Cartridge Style Booths High Production Booths www.globalfinishing.com 1 Non-Recovery Powder Booths GFS Non-Recovery
More informationBULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven
BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 500REOZVB 550/600REOZV Weather Enclosure Sound Enclosure Weather Enclosure Features
More informationThink Dustless..com MAGNUM 5000
.com MAGNUM 5000 Prep/Spray Work Station Reduce Cycle Time, Increase Profits... The is the ultimate in prep and finishing speed. Airflow and workspace conditions are engineered and optimized for prep,
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 (includes KD1250-A) Level 1 Sound Enclosure with Lift Base Sound Level
More informationCEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.
CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE Ideal for all Agricultural applications. These durable ceiling inlets are rotational moulded with high impact polyethylene. They are designed to offer
More informationTube Axial Inline Fans
Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 Level 1 Sound Enclosure with Lift Base Sound Level 1 Enclosure
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.
More informationZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS
ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive
More informationGlobal Finishing Solutions. Powder Booths. > Non-Recovery. > Cartridge System (Powder Collection) > High Production Systems.
Global Finishing Solutions Powder Booths > Non-Recovery > Cartridge System (Powder Collection) > High Production Systems www.globalfinishing.com GFS POWDER BOOTHS Non-Recovery Powder Booth are typically
More informationINDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014 WWW.TCF.COM GRAVITY VENTILATORS Overview Gravity Ventilators Models
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following models: 275/300REOZV 350/400REOZVC 450REOZVB Weather Sound Weather Features Critical silencer, flexible
More informationbelt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07
belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationThe Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB
The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.
More informationINSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationCustom Metal Fabrication - HVAC Air Duct and Fittings
Custom Sheet Metal Metal Forming Accessories Hardware Supplies Custom Metal Fabrication - HVAC Air Duct and Fittings 4120 Ridgeway Drive - Unit 28 Mississauga - Ontario - L5L 5S9 Tel 905-624-3854 / 905-290-2334
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation
More informationROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationTORIN by: AIRDEX Index Page No.
Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -
More informationINSTALLATION INSTRUCTIONS ISLAND LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationMODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS
Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except
More informationTURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)
TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning
More informationCentrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...
More informationInline and Roof Mounted Fans
CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive
More informationINSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationProtector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector
Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory
More informationINSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO
More informationSECTION AXIAL HVAC FANS
SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and
More informationSECTION HVAC POWER VENTILATORS
SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationINSTALLATION INSTRUCTIONS K SERIES LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS ISLAND RANGE HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationModel ND-2 Specification
Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction
More informationGRAVITY VENTILATORS SIZING
GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to
More informationINSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD
More informationFixed Pitch Vane Axial Fan
Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3
More informationINSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationSECTION DUST COLLECTOR
PART1-GENERAL 1.1 DESCRI PTION A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract Drawings. 1.2 SUBMITTALS
More informationINSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD
More informationTwin City Fan & Blower
BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO
More informationINSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationHazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual
Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,
More informationConnection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)
R DESIGNER SERIES WALL MOUNT RANGE HOOD JDH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height
More informationConnection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)
R DESIGNER SERIES WALL MOUNT RANGE HOOD JPH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height
More informationINSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationRequires Ductwork and Blower
6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and
More informationHORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change
More informationTube Axial Fan Page Specifications & Dimension Data Performance Data
Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications
More informationMixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data
Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8
More informationClimas y Proyectos Leyco, S.A. de C.V.
GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA
More informationTubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct
Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-
More informationINSTALLATION INSTRUCTIONS ISLAND RANGE HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationTURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP
TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model
More informationSquare Inline Fans with Multi-Directional Discharge
SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension
More informationFUME HOOD SELECTION GUIDE
FUME HOOD SELECTION GUIDE FUME HOOD SELECTION GUIDE Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous
More informationLow Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear
13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2
More informationMODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS
R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as
More informationINSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationENERGY RECOVERY SYSTEM 60 HZ
I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationdownflo workstation dust collectors
downflo workstation dust collectors Outperforms all other collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line
More informationOur heritage enables us to take a small company approach to the day to day activities of each and every customer.
Our Company... Air Flow Technology, Inc. started in business in the mid-1980 s... by calling directly on body shops and end users. We are now a full line manufacturer of quality synthetic HVAC, industrial
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing
More informationTURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE
TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationTURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)
TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof
More informationCustom Metal Fabrication - HVAC Air Duct and Fittings
Custom Sheet Metal Metal Forming Accessories Hardware Supplies Custom Metal Fabrication - HVAC Air Duct and Fittings 4120 Ridgeway Drive - Unit 28 Mississauga - Ontario - L5L 5S9 Tel 905-624-3854 / 905-290-2334
More information