1 SQN

2 Square Inline Fans with Multi-Directional Discharge Page Introduction Standard Construction Features Specifications and Dimension Data SQN-D SQN-B SQN-HP Accessories Optional Side Discharge Typical Side Discharge Applications Performance Data SQN-D SQND-EC SQN-B SQN-B / SQN-HP Sound Data SQND SQND-EC SQN-B / SQN-HP Other Available Products

3 INTRODUCTION Cook s SQN - Square Inline Fan - is the most versatile fan in the industry. The SQN has the shortest depth of any available square inline fan. Standard universal mounting feet allows the customer to have total control of the fan s installation without the need to purchase any mounting accessories. Three access doors allow total access to the fans internal components in any vertical or horizontal mounting installation. By utilizing the side discharge options, installation costs, pressure loss, system effect and space requirements are reduced. (Side discharge options are illustrated on page 1) The SQN-B, SQN-HP, SQN-D, and SQND-EC are licensed to bear the AMCA Certified Ratings Seal for Air and Sound Performance. SQN-B/SQN-D Available in 7 direct drive sizes and 18 belt drive sizes. Capacities range from 1 to 26, CFM, with static pressures from to 2-1/2 inches. SQN-HP Available in 13 belt drive sizes. Capacities range from 1 to 22, CFM, with static pressures from 1/4 to 5 inches. SQND-EC SQND s with electronically commutated (EC) motors are available in 5 sizes with capacities from 1 to 26 CFM. SQN-B / SQN-HP SQN-D 2

4 STANDARD CONSTRUCTION FEATURES SQN-B Aluminum Wheel Lifting Lugs Integral Inlet & Duct Collars (3) Access Doors Regreasable Pillowblock Bearings in Cast Iron Housing SQN-D Field Wiring Compartment Lifting Lugs Aluminum Wheel Enclosed Motor Standard on Sizes 7-1 Motor Enclosure Standard on Sizes

5 SQN-D Specifications and Dimension Data Direct Drive Loren Cook Company certifies that the SQN-D and SQND-EC shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Description - Fan shall be duct mounted, direct driven centrifugal square inline. Certifications - Fan shall be listed by Underwriters Laboratories (UL 75) and UL listed for Canada (CSA Standard M1984). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction - The fan shall be of bolted construction utilizing corrosion resistant fasteners. Housing shall be minimum 18 gauge galvanized steel with integral duct collars. Bolted access doors shall be provided on three sides, sealed with closed cell neoprene gasketing. Housing shall be pre-drilled to accommodate universal mounting feet for vertical or horizontal installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM and static pressure. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Wheel - Wheel shall be centrifugal backward inclined, constructed of 1 percent aluminum, including a precision machined cast aluminum hub. An aerodynamic aluminum inlet cone shall be provided for maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 24-5, Balance Quality and Vibration Levels for Fans. Motor - Motor shall be heavy duty type with permanently lubricated sealed bearings and furnished at the specified voltage, phase and enclosure. Motor (SQN-D) - Motor shall be NEMA design B with a minimum of class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Motor (SQND-EC) - Motor shall be an electronically commutated motor rated for continuous duty and furnished either with internally mounted potentiometer speed controller or with leads for connection to -1 VDC external controller. Product - Fan shall be model SQN-D or SQND-EC as manufactured by Loren Cook Company of Springfield, Missouri. Type SQN-D and SQND-EC is furnished standard with UL 75 Listing (Power Ventilator/ ZACT) when furnished with factory supplied motor. A OD D Sq. A OD E Type SQN-D and SQND-EC is furnished standard with C UL Listing (Power Ventilator) when furnished with factory supplied motor. A OD Inlet View B C A OD Discharge View SQN-D Dimension Data Size A B C D Sq. E Inlet and Rear Discharge Duct Size (ID) Optional Side Discharge Duct Size (WxH) (ID) Approx. Ship Wt.* /16 1 sq. 6-1/8 x 6-15/ /16 12 sq. 9-1/8 x 8-15/ /16 12 sq. 14-1/8 x 8-15/ / sq. 14-1/8 x 12-9/ /4 22-1/4 2-3/4 22-5/16 18 sq. 14-1/4 x 13-1/ /8 23-7/ /16 2 sq /16 x 16-1/ / /8 22 sq. 19-1/8 x 18-1/8 2 All dimensions in inches. *Weights in lbs, including motor. 4

6 Specifications and Dimension Data SQN-B Description - Fan shall be duct mounted, belt driven centrifugal square inline. Certifications - Fan shall be listed by Underwriters Laboratories (UL 75) and UL listed for Canada (CSA Standard M1984). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction - The fan shall be of bolted construction utilizing corrosion resistant fasteners. Housing shall be minimum 18 gauge galvanized steel with integral duct collars. Bolted access doors shall be provided on three sides, sealed with closed cell neoprene gasketing. Pivoting motor plate shall utilize threaded L-bolt design for positive belt tensioning. Housing shall be pre-drilled to accommodate universal mounting feet for vertical or horizontal installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Wheel - Wheel shall be centrifugal backward inclined, constructed of 1% aluminum, including a precision machined cast aluminum hub. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 24-5, Balance Quality and Vibration Levels for Fans. Motor - Motor shall be NEMA design B with class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings - Bearings shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a pillowblock cast iron housing selected for a minimum L5 life in excess of 2, hours at maximum cataloged operating speed. Belts and Drives - Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 15% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product - Fan shall be model SQN-B as manufactured by Loren Cook Company of Springfield, Missouri. Belt Drive Loren Cook Company certifies that the SQN-B shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Type SQN-B is furnished standard with UL 75 Listing (Power Ventilator/ZACT) when furnished with factory supplied motor. Type SQN-B is furnished standard with C UL Listing (Power Ventilator) when furnished with factory supplied motor. SQN-B Dimension Data Size A B C D Sq. E Inlet and Rear Discharge Duct Size (ID) Optional Side Discharge Duct Size (WxH) (ID) Max. Mtr. Frame Size Approx. Ship Wt.* /2 12 sq. 14-1/8 x 8-15/16 143T /2 12 sq. 14-1/8 x 8-15/16 143T /2 12 sq. 14-1/8 x 8-15/16 143T /2 12 sq. 14-1/8 x 8-15/16 143T / /2 16 sq. 14-1/8 x 12-9/16 145T /4 22-1/4 2-3/4 12-1/2 18 sq. 14-1/4 x 13-1/8 145T /8 23-7/ /4 2 sq /16 x 16-1/8 145T / /4 22 sq. 19-1/8 x 18-1/8 182T /8 14-3/4 24 sq. 21 x 2-1/8 182T /4 32-1/ / sq. 23-1/4 x 22-1/8 182T / sq. 24-1/2 x 24-1/8 182T /4 37-1/4 33-1/2 15-1/4 3 sq. 26-3/4 x 26-1/8 184T /4 33 sq. 26-1/16 x 29-1/8 213T / /2 41-1/ / /4 36-7/16 sq /16 x 32-1/2 213T /4 4 sq. 3-1/8 x 36-1/8 213T /4 45-3/4 48-7/ /4 44 sq. 31-3/16 x 4-1/8 215T /4 46 sq. 32-3/16 x 42-1/16 215T /4 46-1/4 5-1/4 55-1/8 17-1/4 5-3/4 sq. 36-5/16 x 46-15/16 215T 65 All dimensions in inches. *Weights in Lbs, Less Motor and Drives. 5

7 SQN-HP Specifications and Dimension Data Belt Drive High Pressure Loren Cook Company certifies that the SQN-HP shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Type SQN-HP is furnished standard with UL 75 Listing (Power Ventilator/ZACT) when furnished with factory supplied motor. Description - Fan shall be duct mounted, belt driven, high pressure centrifugal square inline. Certifications - Fan shall be listed by Underwriters Laboratories (UL 75) and UL listed for Canada (CSA Standard M1984). Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction - The fan shall be of bolted construction utilizing corrosion resistant fasteners. Housing shall be minimum 18 gauge galvanized steel with integral duct collars. Bolted access doors shall be provided on three sides, sealed with closed cell neoprene gasketing. Pivoting motor plate shall utilize threaded L-bolt design for positive belt tensioning. Housing shall be pre-drilled to accommodate universal mounting feet for vertical or horizontal installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Wheel - Wheel shall be high pressure centrifugal backward inclined, constructed of 1% aluminum, including a precision machined cast aluminum hub. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 24-5, Balance Quality and Vibration Levels for Fans. Motor - Motor shall be Nema design B with class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings - Bearings shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a pillowblock cast iron housing selected for a minimum L5 life in excess of 2, hours at maximum cataloged operating speed. Belts and Drives - Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 15% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product - Fan shall be model SQN-HP as manufactured by Loren Cook Company of Springfield, Missouri. Type SQN-HP is furnished standard with CUL Listing (Power Ventilator) when furnished with factory supplied motor. SQN-HP Dimension Data Size A B C D E Inlet and Rear Discharge Optional Side Discharge Max.Motor Duct Size (ID) Duct Size (WxH) (ID) Frame Size Approx. Ship Wt.* /4 22-1/4 2-3/4 12-1/2 18 sq. 14-1/4 x 13-1/8 145T /8 23-7/ /4 2 sq /16 x 16-1/8 145T / /4 22 sq. 19-1/8 x 18-1/8 182T /8 14-3/4 24 sq. 21 x 2-1/8 182T /4 32-1/ / sq. 23-1/4 x 22-1/8 182T / sq. 24-1/2 x 24-1/8 182T /4 37-1/4 33-1/2 15-1/4 3 sq. 26-3/4 x 26-1/8 184T /4 33 sq. 26-1/16 x 29-1/8 213T / /2 41-1/ / /4 36-7/16 sq /16 x 32-1/2 213T /4 4 sq. 3-1/8 x 36-1/8 213T /4 45-3/4 48-7/ /4 44 sq /16 x 4-1/8 215T /4 46 sq. 32-3/16 x 42-1/16 215T /4 46-1/4 5-1/4 55-1/8 17-1/4 5-3/4 sq. 36-5/16 x 46-15/16 254T 65 All dimensions in inches. *Weights in Lbs, Less Motor and Drives. 6

8 Universal Mounting - The SQN is provided with universal mounting feet for installation in any horizontal or vertical position. These feet are shipped loose for field installation in the desired location. The mounting feet are attached utilizing existing bolts in the fan. See the adjacent drawings for typical positions and dimensions. C Not on direct drive Vertical Floor or Ceiling D C A B B A Horizontal Floor or Ceiling - Motor on side Not on direct drive Not on direct drive D A D Horizontal Floor or Ceiling - Motor on top or bottom SQN-B Size A B C D / / / / / / / / / / / / / /8 16-3/8 21-7/ /8 24-3/8 18-5/8 23-3/ /4 26-1/ / / / /8 23-1/4 28-1/ /8 3-5/8 25-1/2 3-3/ /8 33-1/ / / / / /8 36-5/8 31-1/2 36-1/ / /4 4-3/ / / / / / /4 48-3/ /8 53-1/8 45-1/ / / /4 54-3/ /8 6-1/8 51-7/8 59-1/2 All dimensions in inches. SQN-D ACCESSORIES Size A B C D / / / / / / / / / / /8 16-3/8 21-7/ /8 24-3/8 18-5/8 23-3/ /4 26-1/ / / / /8 23-1/4 28-1/16 All dimensions in inches. Motors Direct Drive All direct drive motors are standard single phase 115-volt. Sizes 7 through 1 are either shaded pole or permanent split capacitor type motors. Sizes 12 through 165 are either permanent split capacitor (175 RPM motors) or split phase (1725 RPM motors). FSC can only be used on either shaded pole or permanent split capacitor type motors. Optional motors: Two speed, single-phase open motors supplied as 1725 RPM motors are 1725/114. Explosion proof motors are available for some units, contact factory for details. These optional motors cannot use an FSC. EC Motors Electronically Commutated (EC) Motors offer significantly improved energy efficiency and controllability over traditional fractional HP motors. The EC motor is offered in 1/4, 1/2 and 3/4 HP sizes for 12v, single phase applications and has an adjustable speed range of 5 to 1725 rpm. Two control options are available for each motor. The Motor Mounted Speed Control version includes an integral potentiometer mounted on the exterior of the motor for adjusting the motor speed. A screwdriver is used for adjustment. The External Signal Speed Control version requires a -1 VDC control signal to adjust the speed of the motor as well as a 24 VAC power source to operate the motor control circuit (a 24v transformer is included with the fan to power the motor control circuit). The motor will operate from 2-1 VDC and will turn off when the control signal is below 1.9 VDC. Belt Drive Single-phase motors: Open drip motors from 1/6 to 1-1/2 HP. Two-speed, motors in 1725/114 RPM, from 1/6 to. TEFC and Class 1, Group D, explosion proof motors from 1/4 to. Three-phase motors: Three-phase ODP motors from 1/4 to 15 HP. Two-speed, two winding motors in 1725/114 RPM, from 1/3 to 5 HP. TEFC and Class 1, Group D, explosion proof motors from 1/4 to. Variable Frequency Drive (VFD) compatible motors are available, contact factory for details. All single-phase and three-phase, single speed, open drip motors listed in performance tables are shipped factory installed. 7

9 ACCESSORIES Fan Speed Control 5 AMP FSC 1 AMP FSC Cook s FSC is a variable speed controller which can offer excellent energy conservation and lower sound levels when 1 percent of a direct drive fan operating capacity is not required. The FSC employs solid state circuitry for long life and dependability. The FSC is available only on 115V and 23V shaded pole or permanent split capacitor direct drive motors and is not available on 114 RPM and 1725 RPM motors. The FSC is normally shipped loose for field installation. Optional pre-wiring is available. Fan Speed Control for EC Motors External Speed Control for the Cook EC Motor allows the fan speed to be adjusted remotely via an easy to read dial. The controller allows for adjustment from 2-1% of the fan speed. The controller works with the external signal version of the Cook EC Motor and requires 24 VAC power for operation. Pressure control for EC Motors Constant pressure controller for the Cook EC Motor is for applications where the fan is intended to maintain a near constant pressure in a system such as dryer vents. The pressure controller reads the pressure in a duct system via the provided pressure transducer and automatically adjusts the fan rpm to maintain a preset value. The controller works with the external signal version of the Cook EC Motor and is shipped loose for field installation. Optional Coatings Lorenized is an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum 2 mil thick baked powder finish. Coating must exceed 1, hour salt spray under ASTM B117 test method. Cook Epoxy Powder is an electrostatically applied, baked epoxy powder coating. Final coating thickness is mils. For outdoor applications an optional UV resistant topcoat is available to prevent cosmetic chalking of the coating. Cook Phenolic Epoxy Powder is an electrostatically applied, baked phenolic epoxy powder coating. Final coating thickness is 2-4 mils. For outdoor applications an optional UV resistant topcoat is required to prevent deterioration of the coating. Cook Easy Clean Powder is an electrostatically applied, baked modified epoxy silicone powder producing a high temperature non-stick coating. Final coating thickness is mils. Air Dry Phenolic (Heresite VR-54) is a conventional spray applied phenolic resin coating. Final coating thickness is 4-6 mils. For outdoor applications an optional UV resistant topcoat (Heresite UC-55) is required to prevent deterioration of the coating. Refer to the corrosion resistance guide in the Compute-A-Fan software for a listing of the coatings above and their resistance to a variety of chemicals. Additional special coatings are available. Read more in the Coating catalog 8

10 ACCESSORIES Belt Tensioner - Cook s automatic belt tensioner eliminates the need for regular manual retensioning of fan belts. The risk of inadvertantly over-tensioning drive components is avoided and overall drive operating efficiency is enhanced. Available on sizes to maintain proper belt tension. Motor Cover - The motor cover completely encloses the motor and drive assembly and also serves as an OSHA belt guard. The motor cover is constructed of 18 gauge galvanized steel and is intended for indoor use only. Motor covers are factory installed. Belt Guard - Belt guards are available which cover the drive assembly on the top, front and sides. The belt guard is constructed of minimum 18 gauge galvanized steel and has an open back which allows inspection and belt tensioning without removing the guard. Belt guards are factory installed. Inlet Safety Screen - Inlet safety screens are used in nonducted installations to protect personnel and prevent debris from entering the fan. This screen is constructed of 1/2 x 1/2 galvanized welded wire and is factory installed. Flex Duct Connector - Flex Duct Connectors are available for the inlet or outlet of the SQN. These connectors provide a flexible connection between the fan and the attached ductwork. This reduces the transmission of noise and vibration to the ductwork as well as allowing for slight misalignment and easy removal of the fan without disturbing the rigid ductwork. Flex Duct Connectors consist of reinforced neoprene fabric and aluminum bands. Safety Screen - safety screens are used on non-ducted installations to protect personnel and prevent debris from entering the fan. This screen is constructed of 16 gauge 1/2 x 1 expanded metal complete with mounting frame. This assembly is Lorenized and factory installed. Filter Box - A Filter Box is available which attaches to the inlet side of the SQN. This filter box is constructed of minimum 18 gauge galvanized steel and incorporates a removable access panel, washable slide-out filters and integral duct collars. Disposable filters are also available. Inlet/ Companion Flange - Inlet or Companion Flanges are available for use in conjunction with the optional Flanged Inlet or. The companion flange is attached to the adjacent ductwork to provide an exact mate to the flanged connection on the fan. Flanged Inlet/ - Flanged Inlet or connections are available which allow for flange type duct attachment in place of the standard slip connection. This type of connection allows the fan to be removed without disturbing the surrounding ductwork. Flanges are constructed of 1-1/2 x1-1/2 x1/8 structural angle and are factory mounted. 9

11 ACCESSORIES Disconnect Switches Backdraft Dampers - Backdraft dampers are available in gravity operated or motorized configurations for in-duct installation. These dampers feature an extruded aluminum frame, aluminum blades and aluminum hinge pins with nylon bushings. These dampers are shipped loose for field installation. NEMA 1 - Indoor general purpose. NEMA 1 (Lockable) - Indoor general purpose with locking capability. NEMA 4 - Watertight and dust-tight. NEMA 7 and NEMA 9 - Lockable, indoor, explosion proof. External Inlet Vane Damper - External Inlet Vane Dampers are used to provide precise air volume control while maintaining maximum efficiency and stable operation at reduced load conditions. Inlet Vane Dampers are available in aluminum or steel construction on sizes 135 through 42. These dampers are factory mounted and provided with an adjustment arm for manual or actuated control (actuator furnished by others). Cataloged performance is based on fans without inlet vane dampers. NEMA 1 NEMA 1 (lockable) NEMA 4 NEMA 7 NEMA 9 Vibration Isolators - Vibration isolation is recommended to reduce vibration and noise transmission to the floor or support structure. Isolators are available in both spring type and RIS (rubber-in-shear) type for floor or ceiling mounting. Housed spring floor isolators are also available where lateral movement must be limited. All isolators are shipped loose for field installation. Model RC RIS Ceiling Model SC Spring Ceiling Model HF Housed Floor Model SF Spring Floor Model RF RIS Floor Additional Accessories Insulated Housing - An acoustical lining is available for the interior of the SQN. This fiberglass duct liner provides a reduction in noise of approximately 3dB in each of the eight octave bands. Aluminum Construction - All aluminum construction is available on all sizes of SQN s. 1

12 OPTIONAL SIDE DISCHARGE Single Side Discharge Package - The Single Side Discharge Package consists of a side duct connection collar and a rear discharge block-off panel. This configuration allows air to exit from any one of the non-motor sides of the unit and provides tremendous versatility in installation. The rear discharge block-off panel is shipped installed on the unit and the side duct connection collar is shipped loose for field installation in place of any one of the three access doors utilizing existing bolts in the fan. The tables below indicate the percent change in performance when using the side discharge option. See the following page for some examples of typical installations. Dual Side Discharge Package - The Dual Side Discharge Package is identical to the Single Side Discharge Package with the exception that two sets of duct connection collars are provided. SQN Side Discharge Correction Factors SQN-B SQN-HP SQN-B SQN-HP SQN-D Size Single Dual Single Dual Size Single Dual Single Dual Size Single Dual CFM HP CFM HP CFM HP CFM HP CFM HP CFM HP CFM HP CFM HP CFM HP CFM HP 6 +3% +3% +3% -3% -3% +5% % -2% % % +5% -12% +1% % +2% -6% 7-5% +4% +8% +6% 7 +2% +2% +3% -3% -3% +5% % -2% 21 +1% -1% +5% -12% +1% % +2% -6% 9-4% +3% +8% +5% 8 +2% +2% +3% -4% -3% +5% % -3% % -1% +6% -12% +1% +1% +3% -7% 1-4% +3% +8% +4% 1 +1% +2% +3% -5% -3% +5% % -3% % -2% +6% -12% +1% +1% +3% -7% 12-3% +2% +9% +3% 12 +1% +1% +4% -6% -2% +4% +1% -4% 27 +2% -2% +6% -13% +1% +1% +3% -7% 135-2% +1% +9% +2% % +1% +4% -7% -2% +4% +1% -4% 3 +3% -2% +7% -13% +2% +2% +4% -8% 15-2% +1% +9% +1% 15 +1% +1% +4% -9% -1% +2% +1% -4% 33 +3% -2% +7% -13% +2% +2% +4% -8% 165-1% % +1% % 165 % % +4% -1% % % +1% -5% % -3% +7% -13% +2% +2% +4% -8% 18 % % +5% -12% +1% % +2% -6% 42 +3% -3% +7% -13% +2% +2% +4% -8% The factors indicate the percent change in performance that will occur when using these side discharge options. AMCA certified ratings seal does not apply when these factors are used. 11

13 TYPICAL SIDE DISCHARGE APPLICATIONS 12

14 7-165 SQN-D SQN-D Data Catalog Max. Nominal Motor CFM vs. Static Pressure Number Watts/BHP RPM HP SQN1D 58W / SQN12D 69W / SQN15D 114W / SQN1D 119W 142 1/ SQN12D 137W 16 1/ SQN15D 165W 171 1/ SQN1D 123W / SQN12D 149W 15 1/ SQN15D 181W / SQN1D.115 BHP / *12SQN17D.39 BHP / SQN1D.157 BHP 112 1/ *135SQN17D.62 BHP / SQN1D.294 BHP 113 1/ *15SQN17D 1.15 BHP SQN1D.468 BHP / *165SQN17D 1.81 BHP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). *These fans cannot be used with FSC speed controller. 7SQN1D, 7SQN12D, 7SQN15D.75 9SQN1D, 9SQN12D, 9SQN15D 1. 1SQN1D, 1SQN12D, 1SQN15D SQN1D 7SQN15D 7SQN12D SQN1D 9SQN15D 9SQN12D SQN12D 1SQN1D 1SQN15D 12SQN1D, 12SQN17D SQN1D, 135SQN17D SQN1D, 15SQN17D SQN17D SQN1D 135SQN1D 135SQN17D SQN1D 15SQN17D SQN1D, 165SQN17D SQN1D 165SQN17D

15 SQND-EC Data SQND-EC Catalog Number HP 7SQN17DEC 1/4 9SQN17DEC 1/4 1SQN17DEC 1/4 12SQN17DEC 1/2 Fan RPM Tip Speed FPM Max Watts CFM vs. Static Pressure SQN17DEC 3/ Performance certified is for Installation Type B: Free inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). *These fans cannot be used with FSC speed controller. 7SQN17DEC 9SQN17DEC 1SQN17DEC Operating Range Operating Range Oprating Range SQN17DEC SQN17DEC Operating Range Operating Range

16 6 SQN-B RPM 3123 RPM 2787 RPM 2451 RPM 2115 RPM 1779 RPM 1443 RPM 3795 RPM.25 HP.167 HP 12-1/2 max. 14 sq. 12 Data SQN-B 6 Wheel Diameter 1 Tip Speed (FPM) = 2.62 x RPM 6 SQN-B Max. HP =.15 x (RPM/1) 3 7 SQN-B Max. HP =.17 x (RPM/1) 3 Area = 1. FT 2 Velocity (FPM) = CFM/1. Max. Motor Frame Size - 143T 114 Motor Requirements - 12 and lower RPM 345 Motor Requirements - 25 and greater RPM 768 RPM SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 15

17 7 SQN-B Data Wheel Diameter 1 Tip Speed (FPM) = 2.62 x RPM 6 SQN-B Max. HP =.15 x (RPM/1) 3 7 SQN-B Max. HP =.17 x (RPM/1) 3 Area = 1. FT 2 Velocity (FPM) = CFM/1. Max. Motor Frame Size - 143T 114 Motor Requirements - 12 and lower RPM 345 Motor Requirements - 25 and greater RPM 12-1/2 max. 14 sq SQN-B RPM 3671 RPM 3336 RPM 31 RPM 2666 RPM 2331 RPM 1996 RPM 1661 RPM 991 RPM.25 HP.167 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 16

18 8 SQN-B RPM 3172 RPM 2935 RPM 2698 RPM 2461 RPM 2224 RPM 1987 RPM 175 RPM 128 RPM.25 HP.167 HP 12-1/2 max. 14 sq. 12 Data SQN-B 8 Wheel Diameter 1 Tip Speed (FPM) = 2.62 x RPM 8 SQN-B Max. HP =.28 x (RPM/1) 3 1 SQN-B Max. HP =.32 x (RPM/1) 3 Area = 1. FT 2 Velocity (FPM) = CFM/1. Max. Motor Frame Size - 143T 114 Motor Requirements - 12 and lower RPM 345 Motor Requirements - 25 and greater RPM SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 17

19 1 SQN-B Data Wheel Diameter 1 Tip Speed (FPM) = 2.62 x RPM 8 SQN-B Max. HP =.28 x (RPM/1) 3 1 SQN-B Max. HP =.32 x (RPM/1) 3 Area = 1. FT 2 Velocity (FPM) = CFM/1. Max. Motor Frame Size - 143T 114 Motor Requirements - 12 and lower RPM 345 Motor Requirements - 25 and greater RPM 12-1/2 max. 14 sq SQN-B RPM 345 RPM 2847 RPM 2649 RPM 2451 RPM 2253 RPM 255 RPM 1857 RPM 1459 RPM.25 HP.167 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 18

20 12 SQN-B RPM 2665 RPM RPM RPM 259 RPM RPM 1655 RPM 1453 RPM RPM.25 HP.167 HP /1 6 sq /2 max. Data SQN-B 12 Wheel Diameter 12 Tip Speed (FPM) = 3.14 x RPM 12 SQN-B Max. HP =.79 x (RPM/1) 3 Area = 1.78 FT 2 Velocity (FPM) = CFM/1.78 Max. Motor Frame Size - 145T 114 Motor Requirements - 12 and lower RPM 345 Motor Requirements - 27 and greater RPM SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 19

21 135 SQN-B / SQN-HP Data Wheel Diameter 13.5 Tip Speed (FPM) = 3.53 x RPM 135 SQN-B Max. HP =.138 x (RPM/1) SQN-HP Max. HP =.93 x (RPM/1) 3 Area = 2.25 FT 2 Velocity (FPM) = CFM/2.25 Max. Motor Frame Size - 145T 114 Motor Requirements - 1 and lower RPM 12-1/2 max. 2-3/4 sq SQN-B 135 SQN-HP RPM 2185 RPM RPM 1891 RPM RPM 1597 RPM RPM 133 RPM RPM.25 HP.167 HP RPM 2445 RPM RPM RPM 1914 RPM 1737 RPM RPM 1383 RPM RPM.25 HP.167 HP 1 2-1/4 22-1/ SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 2

22 Data SQN-B / SQN-HP SQN-B RPM 1959 RPM 1819 RPM 1679 RPM 1539 RPM 1399 RPM 1259 RPM 1119 RPM 835 RPM 1.25 HP.167 HP 2 HP SQN-HP RPM 2695 RPM 2461 RPM 2227 RPM 1993 RPM RPM HP 1525 RPM 1291 RPM 82 RPM.167 HP.25 HP 1 2 HP /4 max. 23 sq /8 23-7/8 Wheel Diameter 15 Tip Speed (FPM) = 3.93 x RPM 15 SQN-B Max. HP =.242 x (RPM/1) 3 15 SQN-HP Max. HP =.96 x (RPM/1) 3 Area = 2.78 FT 2 Velocity (FPM) = CFM/2.78 Max. Motor Frame Size - 145T 114 Motor Requirements - 9 and lower RPM 15 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. 21

23 165 SQN-B / SQN-HP Data Wheel Diameter 16.5 Tip Speed (FPM) = 4.32 x RPM 165 SQN-B Max. HP =.396 x (RPM/1) SQN-HP Max. HP =.195 x (RPM/1) 3 Area = 3.36 FT 2 Velocity (FPM) = CFM/3.36 Max. Motor Frame Size - 182T Reinforced Wheel Requirements - SQN-B = 1833 and greater RPM 25-5/16 sq /4 max. 165 SQN-B 165 SQN-HP RPM 1951 RPM RPM RPM 1483 RPM RPM 1171 RPM 115 RPM.8 74 RPM.167 HP.25 HP 2 HP 1 3 HP RPM 2428 RPM RPM RPM 187 RPM RPM 1393 RPM RPM 1.25 HP 2 HP 769 RPM.167 HP 3 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 22

24 18 SQN-B 18 SQN-HP RPM 166 RPM 1534 RPM 148 RPM 1282 RPM 2 HP RPM 13 RPM 94 RPM.7 65 RPM.167 HP HP 1 3 HP RPM 2 RPM 1831 RPM 1662 RPM RPM RPM RPM HP 986 RPM 1 2 HP.25 HP 647 RPM.167 HP 3 HP /4 max. 27-5/8 sq Data SQN-B / SQN-HP 18 Wheel Diameter 18 Tip Speed (FPM) = 4.71 x RPM 18 SQN-B Max. HP =.59 x (RPM/1) 3 18 SQN-HP Max. HP =.347 x (RPM/1) 3 Area = 4. FT 2 Velocity (FPM) = CFM/4. Max. Motor Frame Size - 182T Reinforced Wheel Requirements - SQN-B = 161 and greater RPM 18 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 23

25 195 SQN-B / SQN-HP Data Wheel Diameter 19.5 Tip Speed (FPM) = 5.11 x RPM 195 SQN-B Max. HP =.88 x (RPM/1) SQN-HP Max. HP =.518 x (RPM/1) 3 Area = 4.69 FT 2 Velocity (FPM) = CFM/4.69 Max. Motor Frame Size - 182T 29-15/16 sq. Reinforced Wheel Requirements - 26 SQN-B = 1429 and greater RPM 15 max. 3-1/4 195 SQN-B 195 SQN-HP RPM 1367 RPM 1254 RPM 1141 RPM 128 RPM 915 RPM 82 RPM 575 RPM 1593 RPM.25 HP.167 HP /4 2 HP 1 3 HP RPM 184 RPM 1653 RPM 152 RPM 1351 RPM 12 RPM 149 RPM 898 RPM.25 HP 595 RPM.167 HP 3 HP 1 2 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 24

26 Data SQN-B / SQN-HP SQN-B 21 SQN-HP RPM 1781 RPM RPM RPM 127 RPM RPM RPM 1364 RPM 115 RPM RPM RPM 823 RPM 186 RPM 727 RPM 947 RPM RPM 536 RPM.25 HP 531 RPM HP 3 HP 1.25 HP 3 HP.167 HP 2 HP 1 15 max. 31-1/4 sq Wheel Diameter 21 Tip Speed (FPM) = 5.5 x RPM 21 SQN-B Max. HP = x (RPM/1) 3 21 SQN-HP Max. HP =.746 x (RPM/1) 3 Area = 5.44 FT 2 Velocity (FPM) = CFM/5.44 Max. Motor Frame Size - 182T Reinforced Wheel Requirements - SQN-B = 1277 and greater RPM 21 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 25

27 225 SQN-B / SQN-HP Data Wheel Diameter 22.5 Tip Speed (FPM) = 5.89 x RPM 225 SQN-B Max. HP = x (RPM/1) /4 max. 225 SQN-HP Max. HP = 1.53 x (RPM/1) 3 Area = 6.25 FT 2 Velocity (FPM) = CFM/6.25 Max. Motor Frame Size - 184T 33-1/2 sq. Reinforced Wheel Requirements - 3 SQN-B =1152 and greater RPM SQN-HP =15 and greater RPM 34-1/4 37-1/4 225 SQN-B 225 SQN-HP RPM 1352 RPM 1245 RPM 1138 RPM 131 RPM 924 RPM 817 RPM 71 RPM RPM HP 2 HP 1 3 HP 5 HP RPM RPM 1559 RPM RPM 1257 RPM RPM 955 RPM RPM 56 RPM 2 HP 5 HP 3 HP 1.25 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 26

28 Data SQN-B / SQN-HP SQN-B RPM 1338 RPM 1242 RPM 1146 RPM 15 RPM 954 RPM 858 RPM 762 RPM 573 RPM.25 HP 3 HP 1 5 HP 7 2 HP SQN-HP RPM 1625 RPM 1477 RPM 1329 RPM 1181 RPM 133 RPM 885 RPM 737 RPM 44 RPM 2 HP 5 HP 1 3 HP /4 max. 36 sq Wheel Diameter 24.5 Tip Speed (FPM) = 6.41 x RPM 245 SQN-B Max. HP = x (RPM/1) SQN-HP Max. HP = 1.75 x (RPM/1) 3 Area = 7.56 FT 2 Velocity (FPM) = CFM/7.56 Max. Motor Frame Size - 213T Reinforced Wheel Requirements - SQN-B = 115 and greater RPM 245 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 27

29 27 SQN-B / SQN-HP Data Wheel Diameter 27 Tip Speed (FPM) = 7.7 x RPM 27 SQN-B Max. HP = x (RPM/1) /4 max. 27 SQN-HP Max. HP = x (RPM/1) 3 Area = 9.18 FT 2 Velocity (FPM) = CFM/9.18 Max. Motor Frame Size - 213T 39-11/16 sq. Reinforced Wheel Requirements /16 SQN-B = 876 and greater RPM SQN-HP = 125 and greater RPM 37-1/2 41-1/2 27 SQN-B 27 SQN-HP RPM 1226 RPM RPM 1138 RPM 15 RPM 135 RPM RPM 1176 RPM RPM RPM 786 RPM 698 RPM.8 61 RPM 1.2 RPM RPM HP RPM 918 RPM HP 2 HP 3 HP RPM 3 HP 2 HP 7 5 HP 27 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 28

30 Data SQN-B / SQN-HP 3 3 SQN-B RPM 954 RPM RPM 814 RPM RPM 674 RPM RPM 534 RPM RPM 2 HP 1 3 SQN-HP RPM 1119 RPM 134 RPM 949 RPM 864 RPM 779 RPM RPM HP 69 RPM 435 RPM 1 3 HP 5 HP /4 max. 44 sq. 4 Wheel Diameter 3 Tip Speed (FPM) = 7.85 x RPM 3 SQN-B Max. HP = 7.71 x (RPM/1) 3 3 SQN-HP Max. HP = x (RPM/1) 3 Area = FT 2 Velocity (FPM) = CFM/11.11 Max. Motor Frame Size - 215T Reinforced Wheel Requirements - SQN-B = 837 and greater RPM SQN-HP = 98 and greater RPM 3 HP 5 HP HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 29

31 33 SQN-B / SQN-HP Data Wheel Diameter 33 Tip Speed (FPM) = 8.64 x RPM 33 SQN-B Max. HP = x (RPM/1) 3 33 SQN-HP Max. HP = x (RPM/1) 3 Area = FT 2 Velocity (FPM) = CFM/13.44 Max. Motor Frame Size - 215T Reinforced Wheel Requirements - SQN-B = 716 and greater RPM SQN-HP = 83 and greater RPM 17-1/4 max. 48-7/16 sq /4 45-3/4 33 SQN-B 33 SQN-HP RPM RPM 828 RPM RPM 694 RPM RPM 56 RPM 493 RPM RPM 3 HP 2 HP 7 5 HP RPM 191 RPM 14 RPM 917 RPM 83 RPM 743 RPM 656 RPM 569 RPM 394 RPM HP 3 HP HP 33 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 3

32 365 SQN-B RPM 733 RPM 68 RPM 627 RPM 574 RPM 521 RPM 468 RPM 415 RPM 37 RPM 3 HP 5 HP 7 2 HP SQN-HP Wheel Diameter RPM 959 RPM 88 RPM 81 RPM 722 RPM RPM RPM2 485 RPM HP 324 RPM 3 HP HP /4 max. 5 sq Data SQN-B / SQN-HP 365 Tip Speed (FPM) = 9.56 x RPM 365 SQN-B Max. HP = x (RPM/1) SQN-HP Max. HP = x (RPM/1) 3 Area = FT 2 Velocity (FPM) = CFM/14.69 Max. Motor Frame Size - 215T Reinforced Wheel Requirements - SQN-B = 624 and greater RPM SQN-HP = 735 and greater RPM 365 SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 31

33 42 SQN-B / SQN-HP Data Wheel Diameter 4.25 Tip Speed (FPM) = 1.54 x RPM Max. HP = x (RPM/1) /4 max. Area = FT 2 Velocity (FPM) = CFM/17.87 Max. Motor Frame Size - 215T Reinforced Wheel Requirements /8 sq. SQN-B = 539 and greater RPM 5-3/4 SQN-HP = 63 and greater RPM 46-1/4 5-1/4 42 SQN-B 42 SQN-HP RPM 638 RPM RPM RPM 53 RPM 458 RPM RPM 368 RPM RPM 2 HP 1 3 HP 7 5 HP RPM RPM 82 RPM RPM 67 RPM RPM 52 RPM RPM 293 RPM 3 HP 2 HP 1 5 HP 15 HP SQN-B.125 SP.25 SP.5 SP.75 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP SQN-HP.25 SP.5 SP 1. SP 1.5 SP 2. SP 2.5 SP 3. SP 4. SP 5. SP Performance certified is for Installation Type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate point of maximum static efficiency. Shaded area indicates reinforced wheel required. 32

34 Sound Data SQND 7SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN12D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN15D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN12D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN15D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN12D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN15D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN17D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN17D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN17D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN1D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi SQN17D L Wi -1 L Wi -2 L Wi -3 L Wi -4 L Wi -5 L Wi -6 L Wi -7 L Wi The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 33

35 SQND-EC Sound Data 7SQN17DEC Sound Power re 1-12 Watts RPM Condition SP L W A Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet SQN17DEC Sound Power re 1-12 Watts RPM Condition SP L W A Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet SQN17DEC Sound Power re 1-12 Watts RPM Condition SP Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi, inlet L W A, outlet L WO, and outlet L WO A sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 34

36 Sound Data SQND-EC 12SQN17DEC Sound Power re 1-12 Watts RPM Condition SP L W A Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet SQN17DEC Sound Power re 1-12 Watts RPM Condition SP L W A Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet Inlet The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 35

37 SQN-B Sound Data 6 SQN-B Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 36

38 Sound Data SQN-B / SQN-HP 12 SQN-B RPM Sound Power re 1-12 Watts SP SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 37

39 SQN-B / SQN-HP Sound Data 15 SQN-B Sound Power re 1-12 Watts SQN-B RPM Sound Power re 1-12 Watts SP SQN-HP Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 38

40 Sound Data SQN-B / SQN-HP 18 SQN-B Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 39

41 SQN-B / SQN-HP Sound Data 21 SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 4

42 Sound Data SQN-B / SQN-HP 245 SQN-B Sound Power re 1-12 Watts SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. 41

43 SQN-B / SQN-HP Sound Data 3 SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts SQN-B The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. RPM Sound Power re 1-12 Watts SP SQN-HP Sound Power re 1-12 Watts

44 365 SQN-B Sound Power re 1-12 Watts SQN-HP Sound Power re 1-12 Watts SQN-B Sound Data SQN-B / SQN-HP The sound power level ratings shown are in decibels referred to 1-12 watts calculated per AMCA Standard 31. The A-weighted sound ratings shown have been calculated per AMCA Standard 31. Values shown are for inlet L Wi and inlet sound power levels for Installation Type B: Free inlet, Ducted outlet. Ratings do not include the effects of duct end correction. RPM Sound Power re 1-12 Watts SP SQN-HP Sound Power re 1-12 Watts

45 OTHER AVAILABLE PRODUCTS Visit lorencook.com to view our complete line of products! 44

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Power Roof and Wall Ventilators

Power Roof and Wall Ventilators Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 6 years, Loren Cook Company believes in superior quality and phenomenal service.

More information

LORENIZED Fan Finish. The COOK Powder Coating Process. Free design tools. Culture of Quality. Independent Certification. Download

LORENIZED Fan Finish. The COOK Powder Coating Process. Free design tools. Culture of Quality. Independent Certification. Download CV Culture of Quality Free design tools Loren Cook Company is proud to be a leader in the design and manufacturing of fans, blowers, gravity ventilators, lab exhaust systems and energy recovery equipment.

More information

Centrifugal Plenum Fan

Centrifugal Plenum Fan PLC Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 60 years, Loren Cook Company believes in superior quality and phenomenal

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

Restaurant Exhaust Ventilator

Restaurant Exhaust Ventilator Restaurant Exhaust Ventilator Page Introduction........................................... 2 Construction Features................................... 3 Specifications & Dimension Data VCRD / VCRD-HP /

More information

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications... Industrial Material Handler Page Introduction.......................................... 2 Information.......................................... 3-5 Specifications MH Specifications.....................................

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

Filtered Air Supply Package Page

Filtered Air Supply Package Page ASP/ASP-T Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 60 years, Loren Cook Company believes in superior quality and phenomenal

More information

Ceiling and Inline Fans

Ceiling and Inline Fans Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of

More information

FILTERED SUPPLY CENTRIFUGAL Belt Drive

FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL - BELT DRIVE SECTION 9 Carnes Models VSBB and VHBB centrifugal filtered roof supply fans are available in six sizes - 8 through 20 with

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive Centrifugal Inline s Models SQ and BSQ Direct and Belt Drive May 21 Models SQ and BSQ Centrifugal Square Inline Duct s Table of Contents Standard Construction Features...4-5 Vari-Green Motor & Control

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

CONSTRUCTION FEATURES AND OPTIONS

CONSTRUCTION FEATURES AND OPTIONS MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

QMXTubular Mixed Flow Product Guide 1

QMXTubular Mixed Flow Product Guide 1 QMXTubular Mixed Flow Product Guide 1 INTRODUCTION QMX has a wide range of benefits. These features make QMX your ideal solution when low sound, high efficiency or compact size are required. DESIGNED FOR

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

DIrect drive exhaust & supply panel fans

DIrect drive exhaust & supply panel fans Air Moving Solutions. DIrect drive exhaust & supply panel fans MODEL BULLETIN 4800 March 2012 Direct DrivePanel ans Model panel fans are direct drive panel fans designed for low static pressures. They

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal, Tubular Inline Fan, Model CIR

Centrifugal, Tubular Inline Fan, Model CIR Centrifugal, Tubular Inline Fan, Model CIR TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 irect rive imensional & Performance ata 7 Belt rive

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

Axial Propeller Panel Fans, PAF-Series

Axial Propeller Panel Fans, PAF-Series Axial Propeller Panel Fans, PAF-Series TABLE OF CONTENTS 3 Introduction 4 Certifications & Listings 4 Options & Accessories 9 Motor Availability 11 Direct Drive Dimensional & Performance Data 14 Belt Drive

More information

ROUND CENTREX Centrifugal Inline Fans

ROUND CENTREX Centrifugal Inline Fans ROUND CENTREX Centrifugal Inline Fans PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS & LISTINGS

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

EcoWatt Products. Advancing Ventilation

EcoWatt Products. Advancing Ventilation EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Bulletin VX05 VANEAXIAL FANS

Bulletin VX05 VANEAXIAL FANS Bulletin VX05 VANEAXIAL FANS Models: VXD, VXB Direct Drive and Belt Drive s VXD/VXB Introduction CERTIFIED RATINGS AMCA Certification UL Certification PennBarry certifi es that the Vaneaxial fans shown

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

CONSTRUCTION FEATURES

CONSTRUCTION FEATURES CONSTRUCTION FEATURES Models FN and FQ direct drive propeller fans are offered for commercial and industrial applications having low noise and high pressure requirements. FQ S These fans are designed to

More information

Downblast Centrifugal Fans with ECM

Downblast Centrifugal Fans with ECM Downblast Centrifugal Fans with ECM Model ered Featuring Electronically Commutated Motors GC_eRED_0512 May 2012 1 Motor Up to 90% efficient, electronically commutated motor (ECM) DOWNBLAST CENTRIFUGAL

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

UPBLAST AXIAL ROOF VENTILATORS

UPBLAST AXIAL ROOF VENTILATORS BULLETIN 616 July 1997 UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile of Aerovent s upblast roof ventilators.

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

2520- EC Motor Speed Controller

2520- EC Motor Speed Controller 2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:

More information

Type VA Vanax Fans. Models VA, VAD, & VAB

Type VA Vanax Fans. Models VA, VAD, & VAB Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

MUFFAN. Filtered Make-up Fresh Air Fans. Moving Your Way BULLETIN MU15 TABLE OF CONTENTS

MUFFAN. Filtered Make-up Fresh Air Fans. Moving Your Way BULLETIN MU15 TABLE OF CONTENTS MUFFAN Filtered Make-up Fresh Air Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings 3 Features & Benefits 4 Direct Drive Dimensional & Performance Data Belt Drive Dimensional

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24 72 Diameter Bulletin PF-1410 July 2003 A Fläkt Woods Company PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003 Fläkt Woods Group Creative Air Fläkt Woods was created by bringing together several of the worlds leading players

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information