3 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LAMPS / MANUFACTURER TOTAL VOLTS WATT A 2 FT x 4 FT PARABOLIC 12 CELL (ELECTRONIC BALLASTS) (2) F032T8 PHILIPS LIGHTOLIER: V. # DPS2G12LS232UNVHI AE SAME AS TYPE-'A' EXCEPT (2) F032T8 PHILIPS LIGHTOLIER: V. #DPS2G12LS232UNVHI-EM A1 2 FT x 4 FT PARABOLIC 12 CELL (ELECTRONIC BALLASTS) (2) F054T5 PHILIPS LIGHTOLIER: v. # DPS2G12LS254UNVPG A1E SAME AS TYPE-'A1' EXCEPT (2) FO54T V. # DPS2G12LS254UNVPG-EM B LED 6" DOWN LIGHT MEDIUM BEAM 39W. LED PHILIPS LIGHTOLIER: 39 #C6L1520DL35KMCCDW BE SAME AS TYPE-'B' EXCEPT 39W. LED PHILIPS LIGHTOLIER: 39 #C6L1520DL35KMCCDW-EM B1 SAME AS TYPE-'B' EXCEPT 39W. LED PHILIPS LIGHTOLIER: 39 WITH DIMMING BALLAST #C6L1520DL35KMCCDW-DIM C LED 4-1/2" DOWN LIGHT 9W. LED PHILIPS LIGHTOLIER: 9 #C4L05DL35KCCDW 120V. #C4LO5N-1 C1 SAME AS TYPE-'C' EXCEPT 9W. LED PHILIPS LIGHTOLIER: 9 WITH DIMMING BALLAST #C4L05DL35KCCDW-DIM 120V. #C4LO5N-1 D 4' FLUORESCENT STRIP (2) F032T8 PHILIPS LIGHTOLIER 48 #SW4S232HPF 120V. #(2) F32/T8/ADV835/ALTO II F 3' FLUORESCENT UNDERCABINET (1) FO25T8 PHILIPS LIGHTOLIER K 120V. #TCU30W120V.RO G 2 FT x 4 FT STATIC (ELECTRONIC BALLASTS) (2) F032T8 PHILIPS LIGHTOLIER: 48 #SPS2GFSVA232 X UNIVERSAL MOUNTING LED EXIT SIGN FACE LED PHILIPS LIGHTOLIER LED RED LETTERS / WHITE, EMERGENCY BATTERY PACK. 120V. #LTN1URW X1 UNIVERSAL MOUNTING LED EXIT DOUBLE FACE LED PHILIPS LIGHTOLIER LED RED LETTERS / WHITE, EMERGENCY BATTERY PACK. 120V. #LTN2URW EM EXTERIOR WALL MOUNTED EMERGENCY UNIT, DARK BRONZE (2) 5.5 W. PHILIPS LIGHTOLIER WITH EMERGENCY BATTERY PACK MR-16 6V./120V. #LVLBZHR

4

5 MAIN DISTRIBUTION PANEL-"MDP" IC: 10,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 600A., COPPER BUS & EQUIP. GRD. MAINS: 600 AMPS, MLO C CCT A SERVES KVA AMPS FRAME TRIP FEEDER / REMARKS NO. T 1 G PANEL-"B" A./3P. 225A. 4#4/0 CU.,1#3 CU.GRD.,2-1/2"C. 2 G PANEL-"A" A./3P. 200A. 4#3/0 CU.,1#6 CU.GRD.,2-1/2"C. 3 C RTU A./3P. 80A. 3#4 CU.,1#8 CU.GRD.,1-1/4"C. 4 C RTU A./3P. 60A. 3#6 CU.,1#8 CU.GRD.,1"C. 5 C RTU A./3P. 50A. 3#8 CU.,1#10 CU.GRD.,1"C. 6 C RTU A./3P. 50A. 3#8 CU.,1#10 CU.GRD.,1"C. 7 C RTU A./3P. 45A. 3#8 CU.,1#10 CU.GRD.,1"C. 8 C RTU A./3P. 30A. 3#10 CU.,1#10 CU.GRD.,3/4"C. 9 SPACE 60A./3P. 10 SPACE 60A./3P. CONNECTED KVA KVA DESIGN FACTOR 1.25 NEC AMPS DESIGN KVA KVA PANEL-"A" SECTION 1 OF 2 IC: 10,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 200 AMPS, MLO 2#12,#12G.,1/2"C. 1 L LIGHTS /1 * 20/1 400 TELE BRD. QUADA R 2 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 3 L LIGHTS /1 * 20/1 200 FIRE ALARM PNL. G 4 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 5 L LIGHTS /1 * 20/1 200 SECURITY PNL. G 6 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 7 l LIGHTS /1 * 20/ COPY PRINT G 8 2#12,#12G.,1/2"C. 8#12,#12G.,3/4"C. 9 R FURNITURE PWR /1 * 20/ COPY MACH. G 10 2#12,#12G.,1/2"C. " 11 R FURNITURE PWR /1 * 20/1 360 COPY ROOM RECEPT. R 12 2#12,#12G.,1/2"C. " 13 R FURNITURE PWR /1 * 20/ COPY PRINT G 14 2#12,#12G.,1/2"C. " 15 R FURNITURE PWR /1 * 20/1 200 RECEPT. R 16 2#12,#12G.,1/2"C. 8#12,#12G.,3/4"C. 17 R FURNITURE PWR /1 * 20/1 900 RECEPT. R 18 2#12,#12G.,1/2"C. " 19 R FURNITURE PWR /1 * 20/1 900 RECEPT. R 20 2#12,#12G.,1/2"C. " 21 R FURNITURE PWR /1 * 20/ RECEPT. R 22 2#12,#12G.,1/2"C. " 23 R FURNITURE PWR /1 * 20/ RECEPT. R 24 2#12,#12G.,1/2"C. 8#12,#12G.,3/4"C. 25 R FURNITURE PWR /1 * 20/1 800 DATA RECEPT. R 26 2#12,#12G.,1/2"C. " 27 R FURNITURE PWR /1 * 20/1 800 DATA RECEPT. R 28 2#12,#12G.,1/2"C. " 29 R FURNITURE PWR /1 * 20/1 800 DATA RECEPT. R 30 2#12,#12G.,1/2"C. " 31 R FURNITURE PWR /1 * 20/1 800 DATA RECEPT. R 32 2#12,#12G.,1/2"C. 8#12,#12G.,3/4"C. 33 R FURNITURE PWR /1 * 20/ COPY PRINTER R 34 2#12,#12G.,1/2"C. " 35 R FURNITURE PWR /1 * 20/1 360 COPY ROOM RECEPT. R 36 2#12,#12G.,1/2"C. " 37 L FURNITURE PWR /1 * 20/ COPY PRINTER R 38 2#12,#12G.,1/2"C. 39 SPARE 20/1 * 20/1 800 FLOOR BOX PWR. R 40 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 41 R RECEPT. (ROOF) /1 * 20/1 SPARE 42 CONNECTED VA KVA DESIGN FACTOR 1.25 NEC AMPS DESIGN VA KVA PANEL-"A" SECTION 2 OF 2 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 200 AMPS, MLO 8#12,#12G.,3/4"C. 43 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 44 8#12,#12G.,3/4"C. " 45 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 46 " " 47 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 48 " " 49 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 50 " 8#12,#12G.,3/4"C. 51 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 52 8#12,#12G.,3/4"C. " 53 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 54 " " 55 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 56 " " 57 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 58 " 8#12,#12G.,3/4"C. 59 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 60 8#12,#12G.,3/4"C. " 61 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 62 " " 63 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 64 " " 65 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 66 " 8#12,#12G.,3/4"C. 67 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 68 8#12,#12G.,3/4"C. " 69 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 70 " " 71 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 72 " " 73 R FURNITURE PWR /1 * 20/1 800 FURNITURE PWR. R 74 " 75 SPARE 20/1 * 20/1 800 FURNITURE PWR. R 76 8#12,#12G.,3/4"C. 77 SPARE 20/1 * 20/1 800 FURNITURE PWR. R 78 " 79 SPARE 20/1 * 20/1 800 FURNITURE PWR. R 80 " 81 SPARE 20/1 * 20/1 800 FURNITURE PWR. R 82 " 83 SPARE 20/1 * 20/1 SPARE 84 PANEL-"B" SECTION 1 OF 2 IC: 10,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 225A. AMPS, MLO 2#12,#12G.,1/2"C. 1 L LIGHTS /1 * 20/ DISPOSAL K 2 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 3 L LIGHTS /1 * 20/ ICE MAKER K 4 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 5 L LIGHTS /1 * 20/ COFFEE MAKER-GFCI K 6 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 7 R DATA RECPT /1 * 20/ MICROWAVE-GFCI K 8 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 9 R DATA RECPT /1 * 20/1 360 KITCH. RECEPT.-GFCI K 10 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 11 R DATA RECPT /1 * 20/1 360 KITCH. RECEPT.-GFCI K 12 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 13 R FLOOR BOX PWR /1 * 20/1 500 REFRIG. K 14 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 15 R DATA RECPT /1 * 20/ COFFEE MAKER K 16 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 17 R DATA RECPT /1 * 20/ COFFEE MAKER K 18 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 19 R DATA RECPT /1 * 20/ COFFEE MAKER K 20 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 21 R DATA RECPT /1 * 20/ COFFEE MAKER K 22 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 23 G AUTO-FLUSH /1 * 20/ RECEPT. R 24 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 25 M CIR. PUMP /1 * 20/ RECEPT. R 26 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 27 R WATER FEATURE /1 * 20/1 360 RECEPT.-GFCI R 28 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 29 R HAND DRYER /1 * 20/ RECEPT. R 30 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 31 R HAND DRYER /1 * 20/ COFFEE MAKER R 32 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 33 R WATER DISP /1 * 20/ COFFEE MAKER R 34 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 35 R DATA RECPT /1 * 20/1 600 TV RECEPT. R 36 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 37 R DATA RECPT /1 * 20/ RECEPT. R 38 2#12,#12G.,1/2"C. 39 SPARE 20/1 * 20/1 600 TV RECEPT. R 40 2#12,#12G.,1/2"C. 41 SPARE 20/1 * 20/1 600 TV RECEPT. R 42 2#12,#12G.,1/2"C. CONNECTED VA KVA DESIGN FACTOR 1.25 NEC AMPS DESIGN VA KVA PANEL-"B" SECTION 2 OF 2 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 225A. AMPS, MLO 2#12,#12G.,1/2"C. 43 O WTR. HRT /2 * 20/ RECEPT. R 44 2#12,#12G.,1/2"C O * 20/ DISHWASHER M 46 2#12,#12G.,1/2"C. 8#12,#12G.,3/4"C. 47 R FURNITURE PWR /1 * 20/1 600 FLOOR BOX PWR. R 48 2#12,#12G.,1/2"C. " 49 R FURNITURE PWR /1 * 20/1 800 FLOOR BOX PWR. R 50 2#12,#12G.,1/2"C. " 51 R FURNITURE PWR /1 * 20/1 SPARE 52 " 53 R FURNITURE PWR /1 * 20/1 SPARE 54 8#12,#12G.,3/4"C. 55 R FURNITURE PWR /1 * 20/1 SPARE 56 " 57 R FURNITURE PWR /1 * 20/1 SPARE 58 " 59 R FURNITURE PWR /1 * 20/1 SPARE 60 " 61 R FURNITURE PWR /1 * SPACE 62 8#12,#12G.,3/4"C. 63 R FURNITURE PWR /1 * SPACE 64 " 65 R FURNITURE PWR /1 * SPACE 66 " 67 R FURNITURE PWR /1 * SPACE 68 " 69 R FURNITURE PWR /1 * SPACE 70 8#12,#12G.,3/4"C. 71 R FURNITURE PWR /1 * SPACE 72 " 73 R FURNITURE PWR /1 * SPACE 74 " 75 R FURNITURE PWR /1 * SPACE 76 " 77 R FURNITURE PWR /1 * SPACE SPACE * SPACE SPACE * SPACE SPACE * SPACE 84

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS

THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS LIGHTING ELECTRICAL SYMBOLS AND ABBREVIATIONS ABBREVIATIONS ELECTRICAL GENERAL NOTES EQUIPMENT POWER DEVICES NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION

More information

Seal Beach Police Department

Seal Beach Police Department Seal Beach Police Department Emergency Services Trailer Operating Manual Prepared by the Seal Beach/Los Alamitos RACES Group Rick Shab, KB6VCM and Mike Maronta KC6YNQ Emergency Services Trailer Page 1

More information

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park. City of Portsmouth Public Works Department June 27, 2014 Addendum #3 Bid #44-14 South Dock Replacement Prescott Park This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement

More information

ADVANCED CALCULATIONS

ADVANCED CALCULATIONS ADVANCED CALCULATIONS 101. Why is it permissible in some cases to fuse a #14 AWG motor conductor with a 60 amp breaker when normally a #14 AWG should only be fused at 15 amps? a) the motor can't start

More information

M-1.0 FILE NAME: CAFE BIZOU CLIENT: CATHERINE MCKENNA PROJECT: PROJECT NO. REV DESCRIPTION DATE PLAN CHECK

M-1.0 FILE NAME: CAFE BIZOU CLIENT: CATHERINE MCKENNA PROJECT: PROJECT NO. REV DESCRIPTION DATE PLAN CHECK PLAN CHECK 11072016 12152016 12312015 : 20161122 20161107 20161215 20161020 PROJECT ME LEGEND, NOTES AND SCHEDULES M1.0 FILE ME: Elec. Panel Locker Rm. Electrical (N.I.C.) New Women's (E) Mop Only Sink

More information

Electrical Existing Conditions and Building Load Summary Report

Electrical Existing Conditions and Building Load Summary Report Electrical Existing Conditions and Building Load Summary Report Executive Summary: This Electrical Existing Conditions and Building Load Summary Report will describe the general and specific characteristics

More information

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith University of California, San Diego Cal (IT) 2 Technical Assignment #2 Brian Smith Advisor: Dr. Moeck 31 October 2005 Brian Smith Lighting/Electrical Option University of California, San Diego Cal (IT)

More information

Diane Emert Senior Thesis 2005 Broadway Plaza, Rochester, MN. Electrical Appendix

Diane Emert Senior Thesis 2005 Broadway Plaza, Rochester, MN. Electrical Appendix Electrical Appendix 121 Panel Switchgear/Panelboard Calculations Future Load (VA) Growth (125%) (VA) FLA (A) Corrected Amps Wire Size Breaker Size (A) 01LNA 38776 48470 134.54 168.17 2/0 175 02LNA 13134

More information

coop erat ive Flood Lights 50W Flood Light GLC-ASFL-50W-1 PERFORMANCE LED Chip Beam Angle 70 Lumen Maintenance Power Factor EMI ENVIRONMENTAL

coop erat ive Flood Lights 50W Flood Light GLC-ASFL-50W-1 PERFORMANCE LED Chip Beam Angle 70 Lumen Maintenance Power Factor EMI ENVIRONMENTAL GreenLight coop erat ive Product Specifications Flood Lights 0W Flood Light GLC-ASFL-0W-1 Flexible, modular design Multiple choice of optical lenses PERFORMANCE LED Chip CREE XT-E Lumen Output (IES),0

More information

A. This section includes unit capacitors for power factor correction.

A. This section includes unit capacitors for power factor correction. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Electrical Design/Build Guide

Electrical Design/Build Guide 2017 Electrical Design/Build Guide Based on the 2017 National Electrical Code Copyright Durand & Associates 1986-2016 60 C Copper Ampacity 4 - Wire Fill - (Non-Current Carrying Neutral) 4 or 5 - Parallel

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

Science 10-Electricity & Magnetism Activity 12 Worksheet on Electrical Energy and Power

Science 10-Electricity & Magnetism Activity 12 Worksheet on Electrical Energy and Power Science 10-Electricity & Magnetism Activity 12 Worksheet on Electrical Energy and Power Name Due Date Show Me Hand In 20 Correct and Hand In Again By Note: Information for this worksheet can be found on

More information

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less. PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other

More information

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2 SPR-2 SPR-2 SPR-2 SPR-2 SPR-2 TYP DH-108 MATCH NE SEE SHEET E. N DH-6 DH-7 DH-9 DH-9 DH-8 DH-6 DH-8 MATCH NE SEE SHEET E. GENERAL NOTES KE PLAN NTS 407 North st Street, Suite 0 (5) 96-050 Fax (5) 96-06 N MATCH NE SEE SHEET E. DH- DH- DH- DH-7

More information

MDP1 SCHEDULE 1 * PANEL A 14194 5450 DISHWASHER * 2 14285 5450 2 2 3 * PANEL B 15445 SPACE * 2 15689 2 4 5 * PANEL C 18860 SPACE * 2 18976 2 6 7 * PANEL D 14000 SPACE * 2 12185 2 8 9 * SPARE SPACE * 10

More information

www.greenelectricalsupply.com 1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

Building & Technology Supplies, LLC

Building & Technology Supplies, LLC THHN STRANDED WIRE AWG AWG #12 4C BX CABLE MC ALUM 12/4 W/GND 250'R AWG #12 3C BX CABLE MC ALUM 12/3 W/GND 250'R AWG #12 THHN WIRE BLK 19STR CU 500'R-10RLS AWG # 12 THHN WIRE WHITE STR CU 500'R-10RLS AWG

More information

AREA OF WORK ENERGY

AREA OF WORK ENERGY THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545 AREA OF WORK THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25

More information

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.

More information

Electrical Depth. Page 81

Electrical Depth. Page 81 Electrical Depth Introduction The existing electrical system for each space redesigned in my lighting depth had to be adjusted accordingly to the new design. The following electrical depth will illustrate

More information

Redbird LED Cardinal Stripit Kit Installation Instructions

Redbird LED Cardinal Stripit Kit Installation Instructions Redbird LED Cardinal Stripit Kit Installation Instructions September 2015 Required Tools & Supplies ü Cordless drill/driver, preferably with adjustable clutch-head with ¼ magnetic hex bit on a 6 extension

More information

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER Page 1 of 5 PRODUCT DESCRIPTION The FL-4020 is a four channel controller add on product for the Architectural dimmer. It provides control of dimmable fluorescent lighting ballasts. The FL-4020 provides

More information

Technical Report 2: Electrical Systems Existing Conditions + Building Load Summary Report

Technical Report 2: Electrical Systems Existing Conditions + Building Load Summary Report Technical Report 2: Electrical Systems Existing Conditions + November 4, 2008 Advisor: Professor Ted Dannerth EXECUTIVE SUMMARY This technical report examines the existing electrical conditions for The

More information

ELASTRIX LLC 95,591 + /- Square Feet on /- acres Pilot Mountain, North Carolina

ELASTRIX LLC 95,591 + /- Square Feet on /- acres Pilot Mountain, North Carolina ELASTRIX LLC 95,591 + /- Square Feet on 19.13 + /- acres Pilot Mountain, North Carolina ELASTRIX, LLC 523 SOUTH STEPHENS ST. PILOT MOUNTAIN, NC 27041 SIZE: GROUND: NUMBER OF BUILDINGS: DIMENSIONS: Approximately

More information

Plan Ahead or Bust the Electric Budget

Plan Ahead or Bust the Electric Budget Plan Ahead or Bust the Electric Budget Almost everyone has paid an electric bill on a house, apartment or some other form of living arrangements. That electric bill is based on the number of kilowatt hours

More information

POWERLINE 2000 Energy Management System TM

POWERLINE 2000 Energy Management System TM Display Panel TM The PowerLine 00 EMS is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed in the standard main distribution

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

Operation Manual Image

Operation Manual Image Operation Manual Image 82, 42, 22 4/14/03 Image 82 8 x 4ft lamps Manual on/off switching control Switches 2 lamps at a time Image 42 4 x 4ft lamps Manual on/off switching control Switches 2 lamps at a

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp

More information

2001 TMT Associates 1

2001 TMT Associates 1 Emerging Lighting Technologies Thomas M. Tolen, LC IEEE 3/21/01 TMT Associates, 2001 1 Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

Emerging Lighting Technologies IEEE - March 21, 2001

Emerging Lighting Technologies IEEE - March 21, 2001 Emerging Lighting Technologies Thomas M. Tolen, LC Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 1 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N R SERVICE MANUAL 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00684-000 LINE 1 LINE 2 6 5 4 3 2 1 6 5 4 3 2 1 M M 1 2 3 4 5 6 A I N A I N INVERTER LOADS SUBPANEL DANGER: HAZARD OF ELECTRICAL SHOCK

More information

Technical Report 2 Drexel University Rec Center Philadelphia, PA

Technical Report 2 Drexel University Rec Center Philadelphia, PA 2010 Technical Report 2 Drexel University Rec Center Philadelphia, PA Britnei Godusky Lighting/Electrical Faculty Advisor: Professor Dannerth 10/27/2010 Executive Summary The following report provides

More information

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

Decorative. PS (cylindrical) Vetro Pendants

Decorative. PS (cylindrical) Vetro Pendants Decorative PS (cylindrical) Project: Location: Cat.No: Type: Lamps: Notes: Qty: Vetro Pendants Power Heads Two-piece cast and machined aluminum outer housing contains electrical components. Hand-blown

More information

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A Pure Sine Wave Power Inverter SSW-350-12A SSW-600-12A SSW-1000-12A SSW-1500-12A SSW-2000-12A Owner's Manual Please read this manual before installing your inverter 1 IMPORTANT SAFETY INSTRUCTIONS THIS

More information

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency

More information

Thomas R. Proctor High School

Thomas R. Proctor High School System Overview Thomas R. Proctor High School has been upgraded from an existing radial electrical system to an expanded radial system. The new system incorporates two separate substations, one located

More information

performance & comfort

performance & comfort Blend performance & comfort in a downlight. CL-DL-VB CALCULITE LED " Total height of Light engine + Reflector ¼" mm PHILIPS LIGHTOLIER, CALCULITE, PROFESSIONAL-GRADE DOWNLIGHTING, LED " ROUND APERTURE

More information

LED microwave sensor T8 tube light

LED microwave sensor T8 tube light LED microwave sensor T8 tube light Product Feature Microwave sensor LED T8 offers a driver and radar sensor intergrated technology. The new technology helps the LED tube save more energy. LED tube will

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR A 19 INCH RACK BASE MOUNT (HEATER/AC) (ENVIRONMENTAL FIELD TERMINAL CABINET) N. J. Specification No. Effective

More information

25' - 6" 4' - 0" 8' - 10" 4' - 0" opt. bath 4. opt. clo. 5' - 6" 17' - 0" opt. bed 4 11' - 6" 10' ceiling. flr. 3' - 5" 3050 sh.dl.

25' - 6 4' - 0 8' - 10 4' - 0 opt. bath 4. opt. clo. 5' - 6 17' - 0 opt. bed 4 11' - 6 10' ceiling. flr. 3' - 5 3050 sh.dl. " " 1' - 10" 17' - 4" " 8' - 0" 8' - 10" 4"" abv. 9' - 4" 4" " " 1' - 10" " wall legend stud wall brick/stone veneer - 20 I.R.C. shall apply. 1' - 4" 1' - 8" 9' - 10" ' - 10" " tub temp. glass enclosure

More information

Cat Description Finish. 1 Hole Plug Gray /4 Hole Plug White /4 Hole Plug Bronze /4 Hole Plug Gray 10 30

Cat Description Finish. 1 Hole Plug Gray /4 Hole Plug White /4 Hole Plug Bronze /4 Hole Plug Gray 10 30 Lampholder & Bar Coded For 75 Thru 150 Watt PAR 38 Lamps Extra Long Wire Leads for Easy Hook-Up Locking Swivel Knuckle Assures Positive Lamp Positioning and Provides Pinpoint Directional Aiming Lampholder

More information

Electricity Merit Badge

Electricity Merit Badge Electricity Merit Badge Class 4 Safety at Home June 13, 2017 Electricity Merit Badge Class 4 2017 National Scout Jamboree 1 Classes Class 1 Basics Electricity Class 2 Magnetism Class 3 Electric Power,

More information

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION FEATURES & SPECIFICATIONS INTENDED USE 131 1 x 4 of applications. Troffer is ideal for all commercial and industrial SIZE W x L x H in inches (mm) 11.75W x.0l x 4.0Dp (0 x 1220 x 100) LAMP 1 or 2 lamp

More information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

Product range overview. MultiColor lights. S-Mitter MultiColor Pages 4-5 LED. Tri-Mitter MultiColor Pages 6-7 LED

Product range overview. MultiColor lights. S-Mitter MultiColor Pages 4-5 LED. Tri-Mitter MultiColor Pages 6-7 LED Product range overview MultiColor lights Versa Inside MultiColor Pages 2-3 LED S-Mitter MultiColor Pages 4-5 LED Tri-Mitter MultiColor Pages 6-7 LED Ballasts + leads 24 Volt Page 8-10 LED Linear lights

More information

MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT GUIDE gpelectric.com

MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT GUIDE gpelectric.com 018 MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT GUIDE sales@gpelectric.com 1.866.7.657 gpelectric.com SINCE 1996 SOLAR INVERTERS CHARGERS BATTERIES For years, Go Power! has been a trusted company in the

More information

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED Adjustable Max. 5 ft. Description Cirrus Suspension Wall Wash with Remote 24VDC power supply (sold separately) is a linear LED fixture that offers a wall wash lens for a smooth and uniform beam spread.

More information

LEDlescent TM T8 Ballast-Free Lamps

LEDlescent TM T8 Ballast-Free Lamps www.sylvania.com LEDlescent TM T8 Ballast-Free Lamps 2 North American Market T8 LED Options Replacement Lamps (UL Type A) Internal Driver Line Voltage Lamps (UL Type B) Single Ended Internal Driver Line

More information

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION FEATURES & SPECIFICATIONS INTENDED USE 1 x 4 of applications. Troffer is ideal for all commercial and industrial SIZE W x L x H in inches (mm) 11.75W x 48.0L x 4.0Dp (300 x 1220 x 100) LAMP 1 or 2 lamp

More information

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032 INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032 Page 1 Thank you for purchasing this Langport Lighting outdoor wall lantern. This product has been manufactured with the highest standards of safety

More information

Therefore, as current is drawn in a circuit to power an appliance, a potential difference occurs across the appliance.

Therefore, as current is drawn in a circuit to power an appliance, a potential difference occurs across the appliance. 16-3 Power Vocabulary Power: The amount of work done in a given unit of time. As seen in the previous chapter, electrical work is done when an amount of charge, q, is transferred across a potential difference,

More information

REQUEST FOR PROPOSAL (RFP) # LED LIGHTING CONVERSION FOR SANTIAGO CANYON COLLEGE AND DISTRICT OPERATIONS CENTER

REQUEST FOR PROPOSAL (RFP) # LED LIGHTING CONVERSION FOR SANTIAGO CANYON COLLEGE AND DISTRICT OPERATIONS CENTER REQUEST FOR PROPOSAL (RFP) #1415-67 LED LIGHTING CONVERSION FOR SANTIAGO CANYON COLLEGE AND DISTRICT OPERATIONS CENTER ADDENDUM # 2 ISSUED AUGUST 18, 2014 The following changes, additions, deletions or

More information

Options. Pole and Arm. Suitable for wet locations

Options. Pole and Arm. Suitable for wet locations Catalog number: / / / Mtg. Fixture Electrical Module Finish See page 2 See page 3 Options Pole and Arm Select pole from Kim Arms and Poles Selection Guide. If pole is provided by others indicate O.D. for

More information

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming S HINE V ENTURE L IGHTING S LED LAMPS Quality retrofit LED lighting products from a leader in the lighting industry Full range dimming Longer life and up to 90% energy savings Long product life and improved

More information

2. Panelboards shall have new or updated paper directories printed from the master Excel spreadsheet inserted in the door

2. Panelboards shall have new or updated paper directories printed from the master Excel spreadsheet inserted in the door 2013 Edition, Published February 28, 2013; Division Revision Date: February 28, 2013 Please add a section for identification. Incorporate the following requirements in your standards. These requirements

More information

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5 Page 1 of 5 Emergency Pack 1 5" (127mm) 24" (610mm) 2-1/2" (64mm) 2" X 2-1/2" Wiring access plate with (2) 7/8" dia. K.O.'s Ordering Information HP90 H9 Direct/Indirect Recessed Fluorescent Body Style

More information

Control Van Electrical Power System 2A5A2

Control Van Electrical Power System 2A5A2 Control Van Electrical Power System 2A5A2 Maintenance Manual 2A5A2-ELEC-MM-1-0 DISTRIBUTION STATEMENT A: APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED. Submarine Rescue System Rescue Capable System

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

FILE # 220V TO 120V CONVERTER

FILE # 220V TO 120V CONVERTER 14 February, 2018 FILE # 220V TO 120V CONVERTER Document Filetype: PDF 367.79 KB 0 FILE # 220V TO 120V CONVERTER JRing 240V Mains To 12V DC Cigarette Lighter Voltage Converter Power Adapter (10A). What

More information

SNL Glass Housings & Accessories

SNL Glass Housings & Accessories Glass Insulators Allanson s Glass Insulators are manufactured from the finest made heat resistant glass; all of our glass housings include a cadmium plated steel ferrule. The # Housing (#HO-) Made to withstand

More information

SECTION ELECTRICAL DESIGN AND CONSTRUCTION STANDARDS _ February A. Use heavy duty type fused and non-fused, enclosed switches only.

SECTION ELECTRICAL DESIGN AND CONSTRUCTION STANDARDS _ February A. Use heavy duty type fused and non-fused, enclosed switches only. 26 20 00 LOW VOLTAGE PART 1: PRODUCTS 1.01 Wiring Devices A. Electrical Requirements 1.02 Disconnect Switches 1. Minimum 20 ampere rated switches shall be used for lighting and power loads. In cases where

More information

Section A: CUSTOMER INFORMATION. Customer Name Electric Account Number Rate Application Number. Facility Address City State Zip Code

Section A: CUSTOMER INFORMATION. Customer Name Electric Account Number Rate Application Number. Facility Address City State Zip Code Commercial & Municipal Retrofit 2015 Lighting Rebate Section A: CUSTOMER INFORMATION Customer Name Electric Account Number Rate Application Number Facility Address City State Zip Service Location Identification

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

R.V & INTERIOR LIGHTING

R.V & INTERIOR LIGHTING R.V & INTERIOR LIGHTING C O N V E N T I O N A L L A M P S 2 74 D O M E L A M P S 2 7 6 F L U O R E S C E N T L A M P S 2 7 8 C O U R T E S Y L A M P S 2 8 1 S W I V E L L A M P S 2 8 3 T R U C K A N D

More information

A direct current (DC) circuit. Alternating Current (AC) Direct Current DC. AC current. L 27 Electricity and Magnetism [4]

A direct current (DC) circuit. Alternating Current (AC) Direct Current DC. AC current. L 27 Electricity and Magnetism [4] L 27 Electricity and Magnetism [4] A direct current (DC) circuit simple electrical circuits direct current DC Alternating current (AC) vs direct current (DC) electric power distribution household electricity

More information

MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT SELLING GUIDE gpelectric.com

MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT SELLING GUIDE gpelectric.com 019 MOBILE SOLAR AND INVERTER SOLUTIONS PRODUCT SELLING GUIDE sales@gpelectric.com 1.866.7.657 gpelectric.com SINCE 1996 SOLAR INVERTERS CHARGERS BATTERIES For 3 years, Go Power! has been a trusted leader

More information

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components

More information

WALL MOUNT - DIRECT/INDIRECT 0.25" Glo Lens 0.25"

WALL MOUNT - DIRECT/INDIRECT 0.25 Glo Lens 0.25 Project Type Louver Notes PERFORMANCE PER LINEAR FOOT AT 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING I/D UPLIGHT DOWNLIGHT Flush Spotless Lens - down Glo Lens - up Glo Lens up and down 1100

More information

So, You re Thinking About Converting to LEDs?

So, You re Thinking About Converting to LEDs? So, You re Thinking About Converting to LEDs? For More Information Please contact: Roberts Research & Consulting, Inc. 3 Garrison Road, Burnt Hills, NY 12027 vic25@robertsresearchinc.com Don t forget to

More information

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL Recessed Project: Location: Cat.No: LP3 paralouver 2x2 Type: Lamps: Notes: Qty: 2 Lamp, T8, T5, or T5HO 9 or 16 cell The Philips Day-Brite / Philips CFI LP3 paralouver recessed is designed to provide the

More information

LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR

LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera MH HID LED Gen 2, a LED plug-and-play replacement, causes the ballast to

More information

3" LED SPECIFICATIONS ULTRA SHALLOW FIXED DOWNLIGHT

3 LED SPECIFICATIONS ULTRA SHALLOW FIXED DOWNLIGHT Small aperture LED downlight with architectural appearance housed in an ultra-shallow " above the ceiling housing. LED module and optics are modular for ease of replacement. Wood ceiling option allows

More information

Universal Retrofit System Installation Instructions Revised:

Universal Retrofit System Installation Instructions Revised: Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to

More information

Electricity. Grade Level: 4 6

Electricity. Grade Level: 4 6 Electricity Grade Level: 4 6 Teacher Guidelines pages 1 2 Instructional Pages pages 3 5 Practice Page page 6 Activity Page page 7 Homework Page page 8 Answer Key page 9 Classroom Procedure: 1. Once students

More information

Specular louver Semispecular. PRF Perforated Top Cover SLD Solid Top Cover. louver. FUS GLR fuse for each ballast

Specular louver Semispecular. PRF Perforated Top Cover SLD Solid Top Cover. louver. FUS GLR fuse for each ballast Photometric Drawing for (1) 28W T5 Lamp CATALOG NUMBER FIXTURE OVERALL ROW LENGTH MAX SECTION LENGTH SHIELDING TOP COVER LAMPING (SEE CROSS SECTION) VOLTAGE OPTIONS* ET1S Enthuse Surface-mount # # must

More information

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8 (1252mm) /16 (551mm) Options Project: Type: Qty: _ Series Height Lamping Finish Voltage Options Series Height Lamping Finish Voltage Options MTR Square Column 2 2 ft. 4 4 ft. 6 6 ft. Metal Halide 2H050 (2x)50w 2H070 (2x)70w T8 2T8

More information

Minimum operation time is 1,000 hours annually. Equipment is listed on the DLC QPL. Minimum operation time is 1,000 hours annually

Minimum operation time is 1,000 hours annually. Equipment is listed on the DLC QPL. Minimum operation time is 1,000 hours annually EXISTING BUILDING INTERIOR LIGHTING Measure Description Rebate/Unit Requirements Interior Retrofit Existing LED Screw-In $2/Lamp Installation of type-a base bulbs: Lamps must be installed in hard-wired,

More information

LIGHTING SPECIFICATIONS

LIGHTING SPECIFICATIONS Incentives: Specifications LIGHTING SPECIFICATIONS All lighting projects are expected to comply with the Illuminating Engineering Society of North America (IESNA) recommended lighting levels or the local

More information

BSA Electricity Merit Badge. Electricity Merit Badge AC Alternating Current

BSA Electricity Merit Badge. Electricity Merit Badge AC Alternating Current Electricity Merit Badge AC Alternating Current AC=Alternating Current Output Output Spinning Wire Coil When a coil of wire passes through a magnetic field it produces an Alternating Current AC=Alternating

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

Lighting Systems Argus-7

Lighting Systems Argus-7 Page 1 of 5 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Rectilinear 3 1.81 (4.6cm) Extruded Linear Louver.5 (.64cm) 5. (1.7cm) 9. (.86cm) 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Tapered 3 1.81 (4.6cm).75 (.7cm) Feature Specifications

More information

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube 3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two

More information

Grid Plus. technical hotline +44 (0) modular wiring devices

Grid Plus. technical hotline +44 (0) modular wiring devices 175 technical hotline +44 (0)1268 563720 range introduction features and benefits is a modular switching and monitoring system in a choice of attractive finishes to match complementary accessory ranges.

More information

Lyon - Ceiling. SIC in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Lyon - Ceiling. SIC in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES: Lyon - Ceiling SIC12106 49 in JOB NAME: TYPE: NOTES: PROJECT DETAILS DESCRIPTION Lyon is a family of small-scale linear LED fixtures that delivers impressive performance at an affordable price. Designed

More information

LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR

LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera Susan Lamp, a LED plug-and-play replacement, causes the ballast to have

More information

6v Cfl Emergency Light Circuit Diagram

6v Cfl Emergency Light Circuit Diagram 6v Cfl Emergency Light Circuit Diagram Readymade emergency light kit setup diagram Circuits DIY - Automatic volt 40 watt ready made emergency cfl/tl circuit looks like. this circuit consists of one power

More information

Notes: 3 13/32. (5) Please consult factory (6) Available with T8 lamp only

Notes: 3 13/32. (5) Please consult factory (6) Available with T8 lamp only PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEWS Direct Indirect 3 13/32 ORDERING CODE 3 13/32 SHOWN WITH LENS OPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PRODUCT SPECIFICATIONS 1 PRODUCT

More information

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V New construction Downlighting Project: Location: Cat.No: LyteCaster Remodeler Type: Lamps: Notes: Qty: Round downlight Philips Lightolier LyteCaster LED Downlights are ideal general purpose downlighting

More information

Reduce Maintenance Costs *

Reduce Maintenance Costs * Reduce Maintenance Costs * Philips Advance programmed start parallel Optanium ballasts for T8 lamps helps lower maintenance costs with independent lamp operation. Philips Advance Optanium high-efficiency

More information

BE A POWER MASTER 10KVA PETROL GENERATOR SRGE12000E GENERATORS INVERTER GENERATORS WATER PUMPS

BE A POWER MASTER 10KVA PETROL GENERATOR SRGE12000E GENERATORS INVERTER GENERATORS WATER PUMPS BE A POWER MASTER 10KVA SRGE12000E S INVERTER S WATER PUMPS PORTABLE S BE A POWER MASTER 2.2kVA SRGE2500 What separates the good from the great is having reliable portable power whenever and wherever you

More information

Lyon Exterior - Wall. SEW in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Lyon Exterior - Wall. SEW in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES: Lyon Exterior - Wall SEW12114 49 in JOB NAME: TYPE: NOTES: PROJECT DETAILS DESCRIPTION Lyon is a family of small-scale linear LED fixtures that delivers impressive performance at an affordable price. Designed

More information

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately New construction Downlighting Project: Location: Cat.No: LyteCaster Remodeler Type: Lamps: Notes: Qty: Round adjustable Philips Lightolier LyteCaster LED Adjustable Downlight is a low cost solution for

More information