Tranquility 20 (TS) Series. SINGLE-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW EARTHPURE SYSTEMS SIZES [ kw]

Size: px
Start display at page:

Download "Tranquility 20 (TS) Series. SINGLE-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW EARTHPURE SYSTEMS SIZES [ kw]"

Transcription

1 Tranquility 20 () Series SINGLE-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW EARTHPURE SYSTEMS SIZES [ kw]

2 Tranquility 20 () Series Table of Contents What's New with thetranquility 20?...3 Tranquility 20 Design Features...4 Unit Model Key...6 About AHRI/ISO/ASHRAE AHRI/ISO/ASHRAE/ANSI Performance...8 Reference Calculations & Legend...9 Air Flow Correction Factors Enterg Air Correction Factors Performance Data Selection Notes Performance Data Physical Data Vertical Upfl ow Dimensions Tranquility 20 () Series Vertical Service Access Horizontal Dimensions Service Access Horizontal Electrical Data Tranquility 20 ECM Electrical Wirg Diagram Tranquility 20 PSC Electrical Wirg Diagram Tranquility 20 ECM Control Features Tranquility 20 ECM Control Features ECM Blower Performance Data PSC Blower Performance Data Auxiliary Electric Heat Engeerg Guide Specifi cations Accessories & Warranty Revision History Vertical Downfl ow Dimensions ClimateMaster: Declare your personal energy dependence.

3 ClimateMaster Geothermal Heatg and Coolg What's New with ClimateMaster's Tranquility 20? EarthPure Refrigerant EarthPure is a non-chlore based (HFC-410A) refrigerant, that with R-407C and R-134A, is seen as the future of all refrigerants used worldwide. HFC-410A characteristics compared to R-22 are: Bary and near azeotropic mixture of 50% R-32 and 50% R-125. Higher effi ciencies (50-60% higher operatg pressures) Zero ozone depletion potential and low global warmg potential. Virtually no glide. Unlike other alternative refrigerants, the two components HFC-410A have virtually the same leak rates. Therefore, refrigerant can be added if necessary without recoverg the charge. MERV 11 2 Pleated filter All Tranquility 20 units clude a factory stalled 2 fi lter rack/ duct collar with a 2 pleated high effi ciency MERV 11 air fi lter. The MERV (mimum effi ciency reportg value per ASHRAE Standard 52.2) design features ultra low velocity (<300 fpm) for extended fi lter life, low pressure drop ( wg.) and high particulate effi ciency (size E1=41%, E2=69% and E3=87%). The pleated design and low velocity combe to allow the fi lter to store a large amount of dirt and result a practical replacement life of up to 6 months. MERV 11 T Plated Air Coil All ClimateMaster Tranquility 20 Series models feature either a t-plated or allalumum air coil. These will provide years of protection agast corrosion from airborne chemicals resultg from modern buildg material out gassg and most environmental chemicals found the air. Modern buildg materials such as counter-tops, fl oor covergs, pats and other materials can outgas chemicals to the home s air. Some of these chemicals are suspected of contributg to corrosion the air coils found both traditional and geothermal heatg and coolg equipment. Corrosion often results refrigerant leaks and eventual failure of the air coil costg hundreds of dollars to replace. Studies have also shown that these air coil coatgs improve moisture sheddg and therefore improve a unit s moisture removal capability resultg a more comfortable home. The Tranquility 20 Series is your assurance of both maximum air coil life and comfort. the critical tolerances required. In the years sce, Copeland has become the leader scroll compressor applications, with ne scroll manufacturg facilities on three contents and millions of units stalled worldwide. Copeland Scroll compressors employ two identical, concentric scrolls, one serted with the other. One scroll remas stationary as the other orbits around it. This movement draws gas to the compression chamber and moves it through successively smaller pockets formed by the scroll s rotation, until it reaches maximum pressure at the center of the chamber. There, it s released through a discharge port the fi xed scroll. Durg each orbit, several pockets are compressed simultaneously, so operation is virtually contuous. Recently, Copeland produced its 500,000th Scroll compressor with the environmentally sound refrigerant HFC-410A. Field results have shown that HFC-410A units with Copeland Scroll compressors offer nearly 30% lower failure rates versus existg R-22 units. HFC-410A units can reach the dustry s highest effi ciency levels. HFC-410A scrolls also offer sound advantages to other compressor technologies, typically operatg several decibels quieter than comparable R-22 models. The result is unsurpassed reliability and virtually silent operation. Other New Features Stylish two-tone look with textured black powder coat pat and staless steel front access panels. Liftout handles for front access panels. Corrosion and sta resistant staless steel dra pan with extra slope designed. Factory mounted fi lter drier for trouble free reliability. Easy access low profi le horizontal control box. Double isolated compressor for quiet and vibration free operation. Foil faced sulation air handlg compartment to allow easy cleang and prevent microfi ber troduction to the air stream. Open Service-Friendly Cabet ( i.e, all components compressor section can be serviced from the front). Copeland Scroll Compressor There s a reason 9 out of every 10 scroll compressors stalled are Copeland. With over 15 years of pastakg R & D and rigid production controls, Copeland is able to build the most reliable, effi cient and quiet scroll compressors the world. The concept of compressg a gas by turng one volute form or scroll agast another around a common axis is nearly a century old. It wasn t until the late 1980s, however that one company Copeland turned theory to practical reality, usg sophisticated, computer-assisted design and manufacturg methods to achieve Residential Products Technical Guide 3

4 Tranquility 20 () Series Tranquility 20 Design Features The Tranquility 20 Series has abundant features and dustry leadg effi ciency. Application Flexibility Eight Capacities 018, 024, 030, 036, 042, 048, 060 and 070. Sgle-stage upfl ow, downfl ow, and horizontal right or left return. Extended range operation ( F EWT) and fl ow rates as low as 1.5 gpm per ton. Optional variable speed ECM fan motor adapts to various duct systems. Internal electric heat unit (optional) designed for easy fi eld stallation. Circuit breaker protected loop and hot water generator pumps. Field selectable low-temperature protection settg for GWHP or GLHP. Standard pre-stalled 2 fi lter frame with 2 high performance MERV 11 pleated air fi lter. Operatg Efficiencies EarthPure HFC-410A zero ozone depletion refrigerant. Among the highest effi ciencies AHRI/ASHRAE/ANSI/ISO sgle stage ratgs for heatg COP s, coolg EER s with low water fl ow rates. 20 EER/4.2 COP. Multi-speed tap PSC fan or optional ECM variable speed fan for ultra high effi ciencies and unsurpassed comfort. Wide operatg temperature range and high effi ciency allow shorter loops. Optional hot water generator with ternal pump generates hot water at considerable savgs. Rugged and highly effi cient next generation Copeland scroll compressors provide the extremely high effi ciencies and capacities. Oversized coaxial tube water-to-refrigerant heat exchangers operate at low liquid pressure drop. Convoluted copper (and optional cupro-nickel) water tube functions effi ciently at low-fl ow rates and provides low-temperature-damage resistance. Oversized t plated, rifl ed tube/lanced alumum fi n, air to refrigerant heat exchangers provide high effi ciency at low face velocity. Large low RPM blowers with optional variable speed fan motors provide quiet, effi cient air movement with high static capability. Exceeds ASHRAE 90.1 and Energy Star 3.0 effi ciencies. Service & Installation Advantages Removable panels - 3 for compressor, 2 for air handlg compartment. Low profi le control box grants easy access to all ternal components. Factory stalled liquid le fi lter/drier. Brass swivel-type water connections for quick connection and elimation of wrenches or sealants durg stallation. Bi-directional thermal expansion valve. Solid state CXM digital compressor control features: anti-short cycle, high & low pressure, loss of charge protection, LED fault, and status dication with memory for easy diagnostics. Circuit breaker protected 75VA control transformer. Optional ECM motor cludes control board with thermostat signal diagnostic LEDs, airfl ow display LED (100 per fl ash), and simplifi ed selection. Insulated divider and separate air handlg/compressor compartments permit service testg without air bypass. Fan motors have quick attach wirg harness for fast removal. Internal dropout blower for easy servicg. High and low pressure service ports on refrigerant circuit. Accurate refrigerant sensg low-temperature protection. Intelligent fault retry- condensate overfl ow protection. Air coil low temperature cut-out usg high accuracy thermistor. 24vac accessory relays. Exclusive UPS (Unit Performance Sentel) feature provides early warng of effi cient operatg conditions before unit shutdown actually occurs reducg the need for emergency service work, thus lettg you fi x problems the early stages. Fault types are not only dicated at the control, but are stored memory after a user reset for future service use. Fault types can be displayed at the thermostat if equipped with fault LED or display. Narrow cabet design for easy movement through doorways. Factory Quality & Industry Certifications All units are built on our Integrated Process Control Assembly System (IPCS). The IPCS is a unique state of the art manufacturg system that is designed to assure quality of the highest standards of any manufacturer the water-source dustry. Our IPCS system: - Verifi es that the correct components are beg assembled. - Automatically performs special leak tests on all jots. - Conducts pressure tests. - Performs detailed run test - Automatically disables packagg for a failed unit. - Creates computer database for future service analysis and diagnostics from run test results. Heavy gauge galvanized steel cabets are epoxy powder coated for durable and long-lastg fi nish. All refrigerant brazg is done a nitrogen atmosphere. All units are deep evacuated to less than 100 microns prior to refrigerant chargg. All jots are both helium and halogen leak tested to sure annual leak rate of less than 1/4 ounce. Coaxial heat exchanger, refrigerant suction les and all water les are fully sulated to elimate condensation problems low temperature applications. Noise reduction features clude: dual level compressor isolation; sulated compressor compartment; terior cabet sulation usg 1/2 coated glass fi ber and optional variable speed fan. Safety features clude: high pressure and loss of charge to protect the compressor; condensate overfl ow protection; lowtemperature protection sensors to safeguard the coaxial heat exchanger and air coil; hot water high-limit and low compressor discharge temperature switch provided to shut down the hot water generator when conditions dictate. Fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker has been reset. Standard 10-year limited warranty on all parts with 5-year labor allowance; Optional additional extended 5-year limited labor allowance available. 4 ClimateMaster: Declare your personal energy dependence.

5 ClimateMaster Geothermal Heatg and Coolg Tranquility 20 Design Features AHRI/ASHRAE/ANSI/ISO certifi ed. ETL listed. US EPA Energy Star compliant. Simplified Controls CXM solid state control module. LED displays airfl ow (optional ECM motor). Dehumidifi cation mode for higher latent coolg (optional ECM motor) Options & Accessories Hot water generator with ternally mounted pump. Cupro-nickel coaxial heat exchanger. Electronic thermostat. Closed loop fl ow controller. Electronic auto-changeover thermostat with 3-stage heat, 2-stage cool and dicator LEDs. Hose kits. Additional extended 5-year limited labor allowance. Internal electric heat (optional) for easy fi eld stallation Copeland High Effi ciency Scroll Compressor or High Effi ciency Rotary Compressor (018) 7 2 Optional variable speed ECM fan motor adapts to various duct systems 3 Foil Faced Insulation In The Blower Section, Fully Insulated Compressor Section 4 5 Two Inch Filter Frame With High Performance MERV 11 Pleated Air Filter* Staless Steel Dra Pan For Long Life Features EarthPure HFC-410A Zero Ozone Depletion Refrigerant 6 Unit Performance Sentel: Automatic Alert System Lets You Know If The System Is Not Runng At Peak Performance** 7 Dual Level Compressor Isolation For Ultra Quiet Operation 8 Five Easy, Lift-out Service Access Panels With Staless Steel Front Panels 7 * MERV= Mimum Effi ciency Reportg Value as specifi ed by ASHRAE (American Society of Heatg, Refrigeratg and Air Conditiong Engeers) standard ** When stalled with a ClimateMaster Residential Thermostat. 6 Residential Products Technical Guide 5

6 Tranquility 20 () Series Unit Model Key V B G C 0 1 A L T 15 S Series = Tranquility Sgle Stage Series Standard S = Standard Configuration V = Vertical Up H = Horizontal D = Vertical Down Unit Size 018, 024, 030, 036, 042, 048, 060, 070 Revision Level B = Current Revision For Size 018 C = Current Revision For Sizes Voltage G = /60/1 Controls C = CXM Cabet 0 = Residential Water Circuit Options 0 = None 1 = HWG w/internal Pum Supply Air Flow & Motor Configuration Option Supply Configuration Motor T D B Top Down Back V D H PSC PSC PSC S Straight H PSC K Top V ECM N Down D ECM P Back H ECM W Straight H ECM PSC motor not available on size 048 and 070 Return Air Flow Configuration L = Left Return R = Right Return Heat Exchanger Options Coated Air Coil/ Microchannel* Copper Cupro-Nickel Standard A J * Microchannel coil ONLY on sizes ClimateMaster: Declare your personal energy dependence.

7 ClimateMaster Geothermal Heatg and Coolg About AHRI/ISO/ASHRAE About AHRI/ISO/ASHRAE AHRI/ASHRAE/ISO (Air-Conditiong and Refrigeration Institute/American Society of Heatg, Refrigeratg and Air Conditiong Engeers/International Standards Organization) is a certifi cation standard for water-source heat pumps used the followg applications: WLHP (Water Loop Heat Pump Boiler/Tower) GWHP (Ground Water Heat Pump Open Loop) GLHP (Ground Loop Heat Pump Geothermal) The directory at is constantly beg updated and immediately available on the Internet. All ratgs are submitted by the manufacturer for certifi cation, and must be approved by AHRI. Therefore, there is a signifi cant difference between AHRI certifi ed and AHRI rated. Thirty percent of a manufacturer s basic models must be tested each year. AHRI selects models at random from stock for testg on the basis of its evaluation of a participant s certifi cation data. Units that fail one or more certifi ed test (90% of declared performance or lower) may be declared defective. If the itial failure is a performance test, the manufacturer must obsolete all units with the same basic model group or elect to have a second sample tested. If the second unit fails a performance test, it must be obsoleted, together with all units with the same basic model group. ClimateMaster takes certifi cation seriously. We were recently awarded a certifi cate for consecutive years of no AHRI failures. Temperatures used AHRI certifi cation standards are S.I. (Système International metric) based. For example, typical catalog data for coolg is shown at 80 F DB/67 F WB [26.7 C DB/19.4 C] enterg air temperature, but the AHRI standard for coolg is 80.6 F DB/66.2 F WB [27 C DB/19 C], sce it is based upon whole numbers degrees Celsius. Water and air temperatures for the standard are shown below. Test Condition Comparison Table WLHP GWHP GLHP Coolg Enterg Air Temperature - DB/WB F [ C] Enterg Water Temperature - F [ C] Fluid Flow Rate 80.6/66.2 [27/19] 86 [30] * 80.6/66.2 [27/19] 59 [15] * 80.6/66.2 [27/19] 77 [25] * Heatg Enterg Air Temperature - DB/WB F [ C] Enterg Water Temperature - F [ C] Fluid Flow Rate 68 [20] 68 [20] * 68 [20] 50 [10] * 68 [20] 32 [0] * *Flow rate is specified by the manufacturer Data certifi ed by AHRI clude heatg/coolg capacities, EER (Energy Effi ciency Ratio Btuh per Watt) and COP (Btuh per Btuh) at the various conditions shown above. Pump power correction is calculated to adjust effi ciencies for pumpg Watts. With each model, only one water fl ow rate is specifi ed for all three groups, and pumpg Watts are calculated usg the formula below. This additional power is added onto the existg power consumption. Pump power correction = (gpm x ) x (Press Drop x 2990)/300 Fan power is corrected to zero external static pressure usg the equation below. The nomal airfl ow is rated at a specifi c external static pressure. This effectively reduces the power consumption of the unit and creases coolg capacity but decreases heatg capacity. Fan Power Correction = (cfm x 0.472) x (esp x 249)/300 Capacities and effi ciencies are calculated usg the followg equations: ISO Coolg = Coolg (Btuh) + [Fan Power Correction (Watts) x 3.412] ISO EER Effi ciency (Btuh/W) = ISO Coolg (Btuh)/[Power Input (Watts) Fan Power Correction (Watts) + Pump Power Correction (Watts)] ISO Heatg = Heatg (Btuh) [Fan Power Correction (Watts) x 3.412] ISO COP Effi ciency (Btuh/Btuh) = ISO Heatg (Btuh) x 3.412/[Power Input (Watts) - Fan Power Correction (Watts) + Pump Power Correction (Watts)] Residential Products Technical Guide 7

8 Tranquility 20 () Series AHRI/ISO/ASHRAE/ANSI Performance ASHRAE/AHRI/ISO English (IP) Units Model Fan Motor Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Coolg 86 F Heatg 68 F Coolg 59 F Heatg 50 F Coolg 77 F Heatg 32 F Btuh EER Btuh/W Btuh COP Btuh EER Btuh/W Btuh COP Btuh EER Btuh/W Btuh 018 PSC 18, , , , , , ECM 19, , , , , , PSC 23, , , , , , ECM 23, , , , , , PSC 28, , , , , , ECM 28, , , , , , PSC 33, , , , , , ECM 33, , , , , , PSC 38, , , , , , ECM 39, , , , , , ECM 48, , , , , , PSC 62, , , , , , ECM 63, , , , , , ECM 71, , , , , , Coolg capacities based upon 80.6 F DB, 66.2 F WB enterg air temperature Heatg capacities based upon 68 F DB, 59 F WB enterg air temperature All ratgs based upon operation at lower voltage of dual voltage rated models COP ASHRAE/AHRI/ISO Metric (SI) Units Model Fan Motor Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Coolg 30 C Heatg 20 C Coolg 15 C Heatg 10 C Coolg 25 C Heatg 0 C kw EER Btuh/W kw COP kw EER Btuh/W kw COP kw EER Btuh/W kw COP 018 PSC ECM PSC ECM PSC ECM PSC ECM PSC ECM ECM PSC ECM ECM Coolg capacities based upon 27 C DB, 19 C WB enterg air temperature Heatg capacities based upon 20 C DB, 15 C WB enterg air temperature All ratgs based upon operation at lower voltage of dual voltage rated models 8 ClimateMaster: Declare your personal energy dependence.

9 ClimateMaster Geothermal Heatg and Coolg Ref er ence Calculations & Legend Heatg LWT = EWT - LAT = EAT + HE GPM x 500 HC x1.08 Coolg HR LWT = EWT + GPM x 500 SC LAT (DB) = EAT (DB) - x1.08 LC = TC - SC S/T = SC TC Hot Water Generator capacities (HWC) are based on potable water fl ow rate of 0.4 gpm per nomal equipment ton and 90 F enterg potable water temperature. = airflow, cubic feet/mute EWT = enterg water temperature, F GPM = water flow US gallons/mute EAT = enterg air temperature, Fahrenheit (dry bulb/wet bulb) HC = air heatg capacity, Mbtuh TC = total coolg capacity, Mbtuh SC = sensible coolg capacity, Mbtuh KW = total power unit put, KiloWatts HR = total heat of rejection, Mbtuh HE = total heat of extraction, Mbtuh HWC = Hot Water Generator (desuperheater) capacity, Mbtuh WPD = Water coil pressure drop (psi & ft hd) EER = Energy Efficiency Ratio = BTU output/watt put COP = Coefficient of Performance = BTU output/btu put LWT = leavg water temperature, F LAT = leavg air temperature, F LC = latent coolg capacity, Mbtuh S/T = sensible to total coolg ratio UPFLOW HORIZONTAL Straight Discharge Left Return Air Pipg End Right Return Air Straight Discharge Residential Products Technical Guide 9

10 Tranquility 20 () Series Air Flow Correction Factors 018 with PSC Fan Motor Airfl ow Coolg Heatg % of Rated Total Sensible S/T Power Heat of Rejection Heatg Power with PSC Fan Motor Airfl ow Coolg Heatg Heat of Extraction % of Rated Total Sensible S/T Power Heat of Rejection Heatg Power Heat of Extraction with ECM Fan Motor Airfl ow Coolg Heatg % of Rated Total Sensible S/T Power Heat of Rejection Heatg Power Heat of Extraction with ECM Fan Motor Airfl ow Coolg Heatg % of Rated Total Sensible S/T Power Heat of Rejection Heatg Power Heat of Extraction ClimateMaster: Declare your personal energy dependence.

11 ClimateMaster Geothermal Heatg and Coolg Enterg Air Correction Factors Unit Size 018 Unit Sizes Enterg Air DB F Heatg Heatg Power Heat of Extraction Enterg Air DB F Heatg Heatg Power Heat of Extraction Unit Size 018 Enterg Air WB F Total Coolg Sensible Coolg Multiplier - Enterg DB F Power Heat of Rejection * * * * * * * * * * * * * * * * * * * * * * * * * * Operation * not recommended Unit Sizes Enterg Air WB F Total Coolg Sensible Coolg Multiplier - Enterg DB F Power Heat of Rejection * * * * * * * * * * * * * * * * * * * * * * * * * Operation not recommended * = Sensible capacity equals total capacity AHRI/ISO/ASHRAE uses enterg air conditions of Coolg F DB/66.2 F WB, 1 and Heatg - 68 F DB/59 F WB enterg air temperature For ClimaDry equipped units the mimum enterg air temperature when coolg is 65ºF DB / 55ºF WB. Operation below this mimum may result nuisance faults. Residential Products Technical Guide 11

12 Tranquility 20 () Series Performance Data Selection Notes For operation the shaded area when water is used lieu of an antifreeze solution, the LWT (Leavg Water Temperature) must be calculated. Flow must be mataed to a level such that the LWT is mataed above 40 F [4.4 C] when the JW3 jumper is not clipped (see example below). Otherwise, appropriate levels of a proper anti-freeze should be used systems with leavg water temperatures of 40 F or below and the JW3 jumper should be clipped. This is due to the potential of the refrigerant temperature beg as low as 32 F [0 C] with 40 F [4.4 C] LWT, which may lead to a nuisance cutout due to the activation of the Low Temperature Protection. JW3 should never be clipped for standard range equipment or systems without antifreeze. Example: At 50 F EWT (Enterg Water Temperature) and 1.5 gpm/ ton, a 3 ton unit has a HE of 22,500 Btuh. To calculate LWT, rearrange the formula for HE as follows: HE = TD x GPM x 500, where HE = Heat of Extraction (Btuh); TD = temperature difference (EWT - LWT) and GPM = U.S. Gallons per Mute. Performance capacities shown thousands of Btuh Heatg - EAT 70 F R HW Airflow HC kw HE LAT COP H /A N/A N/A N/A TD = HE/(GPM x 500) TD = 22,500/(4.5 x 500) TD = 10 F LWT = EWT - TD LWT = = 40 F In this example, as long as the EWT does not fall below 50 F, the system will operate as designed. For EWTs below 50 F, higher flow rates will be required (open loop systems, for example, require at least 2 gpm/ton when EWT is below 50 F). Antifreeze Correction Table Antifreeze Type Propylene Glycol Methanol Ethanol Ethylene Glycol Antifreeze % Total Cap Coolg EWT 40 F Sens Cap Power WPD Corr. Fct. EWT 40 F ClimateMaster: Declare your personal energy dependence.

13 ClimateMaster Geothermal Heatg and Coolg Performance Data Tranquility 20 Model PSC Blower 600 Nomal (Rated) Airflow Coolg, 600 Nomal (Rated) Airflow Heatg EWT F Interpolation is permissible; extrapolation is not. All enterg air conditions are 80 F DB and 67 F WB coolg, and 70 F DB heatg. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB coolg and 68 F DB heatg. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional sulated water/refrigerant circuit. See performance correction tables for operatg conditions other than those listed above. See Performance Data Selection Notes for operation the shaded areas. Performance capacities shown thousands of Btuh WPD Coolg - EAT 80/67 F Heatg - EAT 70 F GPM Airflow PSI FT TC SC kw HR EER HWC Airflow HC kw HE LAT COP HWC Residential Products Technical Guide 13

14 Tranquility 20 () Series Performance Data Tranquility 20 Model ECM Blower Nomal (Rated) Airflow Coolg, 750 Nomal (Rated) Airfl ow Heatg Performance capacities shown thousands of Btuh EWT WPD Coolg - EAT 80/67 F Heatg - EAT 70 F GPM Airflow F PSI FT TC SC kw HR EER HWC Airflow HC kw HE LAT COP HWC Interpolation is permissible; extrapolation is not. All enterg air conditions are 80 F DB and 67 F WB coolg, and 70 F DB heatg. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB coolg and 68 F DB heatg. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional sulated water/refrigerant circuit. See performance correction tables for operatg conditions other than those listed above. See Performance Data Selection Notes for operation the shaded areas. ClimateMaster: Declare your personal energy dependence.

15 ClimateMaster Geothermal Heatg and Coolg Performance Data Tranquility 20 Model PSC Blower 950 Nomal (Rated) Airflow Coolg, 950 Nomal (Rated) Airfl ow Heatg EWT F Interpolation is permissible; extrapolation is not. All enterg air conditions are 80 F DB and 67 F WB coolg, and 70 F DB heatg. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB coolg and 68 F DB heatg. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional sulated water/refrigerant circuit. See performance correction tables for operatg conditions other than those listed above. See Performance Data Selection Notes for operation the shaded areas. Residential Products Technical Guide Performance capacities shown thousands of Btuh WPD Coolg - EAT 80/67 F Heatg - EAT 70 F GPM Airflow PSI FT TC SC kw HR EER HWC Airflow HC kw HE LAT COP HWC

16 Tranquility 20 () Series Performance Data Tranquility 20 Model ECM Blower 950 Nomal (Rated) Airflow Coolg, 950 Nomal (Rated) Airfl ow Heatg Performance capacities shown thousands of Btuh EWT F GPM WPD Coolg - EAT 80/67 F Heatg - EAT 70 F Airflow PSI FT TC SC kw HR EER HWC Airflow HC kw HE LAT COP HWC Interpolation is permissible; extrapolation is not. All enterg air conditions are 80 F DB and 67 F WB coolg, and 70 F DB heatg. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB coolg and 68 F DB heatg. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional sulated water/refrigerant circuit. See performance correction tables for operatg conditions other than those listed above. See Performance Data Selection Notes for operation the shaded areas. 16 ClimateMaster: Declare your personal energy dependence.

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5

More information

GT-PX (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON. SYSTEMS SIZES [ kw]

GT-PX (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON. SYSTEMS SIZES [ kw] (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON SYSTEMS SIZES 026-072 [7.0-19.3 kw] Revised: June 7, 2013 (50YD) Series Table of Contents What s New with Carrier Geothermal?...3

More information

GT-PX (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON. SYSTEMS SIZES [ kw]

GT-PX (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON. SYSTEMS SIZES [ kw] (50YD) Packaged Series TWO-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON SYSTEMS SIZES 026-072 [7.0-19.3 kw] (50YD) Series Table of Contents What s New with Carrier Geothermal s?...51 Design Features...52

More information

GT-PX SPLIT (50YDS) SERIES. Carrier Geothermal Heat Pump Systems GT-PXS 1. All Products Technical Guide:

GT-PX SPLIT (50YDS) SERIES. Carrier Geothermal Heat Pump Systems GT-PXS 1. All Products Technical Guide: Carrier Geothermal Heat Pump Systems GT-PX SPLIT (50YDS) SERIES TWO-STAGE INDOOR SPLIT PURON SYSTEMS SIZES 026-064 [7.0-19.3 kw] All Products Technical Guide: 2006-2007 1 GT-PX Split (50YDS) Series Table

More information

HEAT CONTROLLER, INC. HT Series HT GeoMax2 Two-Stage. 2 to 5 Tons

HEAT CONTROLLER, INC. HT Series HT GeoMax2 Two-Stage. 2 to 5 Tons HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HT Series HT GeoMax2 Two-Stage 2 to 5 2 to 5 Tons HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax

More information

Residential Packaged Geothermal Heat Pump

Residential Packaged Geothermal Heat Pump ENGIneering Design Guide Residential Packaged Geothermal Heat Pump HP Series 1 1 /2 to 5 Tons Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Engineering

More information

TRANQUILITY 20 SINGLE-STAGE (TS) SERIES

TRANQUILITY 20 SINGLE-STAGE (TS) SERIES TRANQUILITY 20 SINGLE-STAGE () SERIES SIZE 006-070 (1.76kW - 21.1kW) HORIZONTAL, VERTICAL & DOWNFLOW R410A - 60Hz STANDARD & EXTENDED RANGE R410A - 60Hz STANDARD & EXTENDED RANGE SIZE 018-070 (5.3kW -

More information

ENGINEERING DESIGN GUIDE

ENGINEERING DESIGN GUIDE ENGINEERING DESIGN GUIDE Commercial Horizontal & Vertical Packaged Water-Source Heat Pumps: Compact Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Table

More information

Compact (HBH/V) Series HBH-HBV

Compact (HBH/V) Series HBH-HBV Submittal Data Compact (HBH/V) Series HBH-HBV 006-60 60Hz - HFC-410A 517.787.2100 www.marsdelivers.com www.heatcontroller.com Compact (HBH/V) Series Submittal Data Models HBH/V 006-060 60Hz - HFC-410A

More information

Tranquility Compact (TC) Series Submittal Data

Tranquility Compact (TC) Series Submittal Data Tranquility Compact (TC) Series Submittal Data Models TCH/V006-060 60Hz - HFC-410A *LC405* LC405 Rev.: August 21, 2018 Table of Contents TC Compact Packaged Series Unit Features 4 Selection Procedure 5

More information

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog. Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3

More information

Tranquility Water-To-Water (TMW) Series

Tranquility Water-To-Water (TMW) Series Tranquility Water-To-Water (TMW) Series Submittal Data Model TMW036-340 60Hz - HFC-410A *LC402* LC402 Rev.: November 18, 2016 Table of Contents TMW Water-To-Water Series Unit Feature 3 Selection Procedure

More information

Tranquility 20 (TS) Series Submittal Data

Tranquility 20 (TS) Series Submittal Data Tranquility 20 (TS) Series Submittal Data Models TSD/H/V 006-070 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engeer: Contractor: PERFORMANCE

More information

Geothermal Heat Pump Systems

Geothermal Heat Pump Systems SUBMITTAL DATA Geothermal Heat Pump Systems Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DATA Cooling Capacity BTUH EER Heating Capacity BTUH COP Model HTS 024-060 60 Hz R-410A Ambient

More information

Tranquility 16 (TR) Series Submittal Data

Tranquility 16 (TR) Series Submittal Data Tranquility 16 () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A *LC516* LC516 Rev.: October 6, 2017 LC516-2 Table of Contents Series Unit Features 4 Selection Procedure 5 Series Nomenclature

More information

Large Belt Drive (HBH/V) Series HBH HBV

Large Belt Drive (HBH/V) Series HBH HBV Design Guide Large Belt Drive (HBH/V) Series HBH 072-120 HBV 072-300 60Hz - HFC-410A 517.787.2100 www.marsdelivers.com www.heatcontroller.com Table of Contents *Page Number Unit Features.... 2 Selection

More information

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility High Efficiency () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A English Language/I-P Units Submittal Data - I-P Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

Tranquility Digital Split (TES/TEP/TAH/TAC) Series. TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES [

Tranquility Digital Split (TES/TEP/TAH/TAC) Series. TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES [ Tranquility Digital Split (TES/TEP/TAH/TAC) Series TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES 026-064 [7.0-19.3 kw] Tranquility Digital Split (TES/TEP/TAH/TAC) Series Table of Contents

More information

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility Large Vertical (TLV) Series Submittal Data Models TLV08-300 50Hz - HFC-10A English Language/S-I Units Submittal Data - S-I Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

Tranquility 16 (TR) Series Submittal Data

Tranquility 16 (TR) Series Submittal Data Tranquility 16 () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE

More information

ENGINEERING DESIGN GUIDE

ENGINEERING DESIGN GUIDE ENGINEERING DESIGN GUIDE HZ series Two-Stage Horizontal Vertical and Downflow System Sizes 024-070 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Table of Contents

More information

GT-PC (50YG) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL, VERTICAL AND DOWNFLOW PURON. SYSTEMS SIZES [

GT-PC (50YG) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL, VERTICAL AND DOWNFLOW PURON. SYSTEMS SIZES [ (50YG) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL, VERTICAL AND DOWNFLOW PURON SYSTEMS SIZES 024-060 [7.0-17.5 kw] Created October 1, 2012 (50YG) Series Table of Contents What s New with Carrier

More information

Tranquility 30 Digital (TE) Series Submittal Data

Tranquility 30 Digital (TE) Series Submittal Data Tranquility 30 Digital (TE) Series Submittal Data Models TED/H/V 026-072 60Hz - HFC-410A *LC991* LC991 Rev.: August 21, 2018 Table of Contents TE Premier Efficiency Series Unit Features 4 igate Communicatg

More information

GT-PW (50YER) Water-to-Water Series. WATER-TO-WATER PURON SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

GT-PW (50YER) Water-to-Water Series. WATER-TO-WATER PURON SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] GT-PW () Water-to-Water Series WATER-TO-WATER PURON SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] GT-PW Water-To-Water () Series Table of Contents Design Features...167 Unit Model Key...169 ARI/ISO/ASHRAE/ANSI

More information

Tranquility Digital Split (TES/TEP/TAH/TAC) Series. TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES [

Tranquility Digital Split (TES/TEP/TAH/TAC) Series. TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES [ Tranquility Digital Split (TES/TEP/TAH/TAC) Series TWO-STAGE INDOOR AND OUTDOOR SPLIT EARTHPURE SYSTEMS SIZES 026-064 [7.0-19.3 kw] Tranquility Digital Split (TES/TEP/TAH/TAC) Series Table of Contents

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

GT-PB (50YF) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL AND VERTICAL PURON. SYSTEMS SIZES [ kw]

GT-PB (50YF) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL AND VERTICAL PURON. SYSTEMS SIZES [ kw] (50YF) Digital Packaged Series TWO-STAGE DIGITAL HORIZONTAL AND VERTICAL PURON SYSTEMS SIZES 024-060 [7.0-17.5 kw] Created October 1, 2012 (50YF) Series Table of Contents What s New with Carrier s /50YF

More information

Tranquility 30 Digital (TE) Series Submittal Data

Tranquility 30 Digital (TE) Series Submittal Data Tranquility 30 Digital (TE) Series Submittal Data Models TED/H/V 026-072 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engeer: Contractor:

More information

Premier Split Specification Catalog

Premier Split Specification Catalog Geothermal Split Units 1-1/2 thru 5 Tons Design Features Dimensional Data Physical Data Premier Split Specification Catalog Performance Data Engineering Guide Specifications SP1557 03/09 WaterFurnace WaterFurnace

More information

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14 ASTON SERIES COMPACT Commercial 0.75-6 Ton Water Source/Geothermal Heat Pump Submittal Data English Language/IP Units SD1022AGA 05/14 Model Nomenclature 1-2 3 4-6 7 8 9 10 11 12 13 14 GB V 048 T L 0 0

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET AFFINITY COMPACT COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE AND DUAL CAPACITY MODELS: YKS009-0 (.75 THRU 6 NOMINAL TONS) YKT026-072 (2 THRU 6 NOMINAL

More information

Trilogy 45 Q-Mode (QE) Series VARIABLE SPEED HORIZONTAL VERTICAL AND DOWNFLOW EARTHPURE SYSTEMS SIZES

Trilogy 45 Q-Mode (QE) Series VARIABLE SPEED HORIZONTAL VERTICAL AND DOWNFLOW EARTHPURE SYSTEMS SIZES Trilogy 45 Q-Mode () Series VARIABLE SPEED HORIZONTAL VERTICAL AND DOWNFLOW EARTHPURE SYSTEMS SIZES 0930 1860 2 ClimateMaster: Declare your personal energy independence. Table of Contents What s New With

More information

Tranquility Ducted Vertical Stack (TSL) Series Submittal Data

Tranquility Ducted Vertical Stack (TSL) Series Submittal Data Tranquility Ducted Vertical Stack (TSL) Series Submittal Data Models TSL09-36 60Hz - HFC-410A *LC1007* LC1007 Rev.: September 1, 2017 Table of Contents TSL Ducted Vertical Stack Series Unit Features 4

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14 ARBOR BASE SERIES OMMERIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD0AZA 05/4 Model Nomenclature -5 6 7 8 9 0 4 5 6 7 8 9 0- Z B V 06 T L 0 0 0 A N A N A 0 SS * Model Type Z Arbor Operation

More information

HEAT CONTROLLER, INC.

HEAT CONTROLLER, INC. HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax 517-787-9341 www.heatcontroller.com MODEL NOMENCLATURE

More information

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional

More information

HEAT CONTROLLER, INC. HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps

HEAT CONTROLLER, INC. HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS HT 024-060 HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS 20D214-06NN 20D214-06NN

More information

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual P.O. Box 245 Syracuse, NY 13211 www.roth-usa.com info@roth-usa.com 888-266-7684 Table of Contents: RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS XT 024-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET LX SERIES EOTHERMAL HEAT PUMPS DUAL APAITY MODELS: YLF026-072 (2 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

FHP s EnviroSaver the best investment for your environment and home.

FHP s EnviroSaver the best investment for your environment and home. EnviroSaver The two-stage EnviroSaver from FHP provides you with a unit that will suit your budget while incorporating innovative technology for reduced energy costs. FHP was the industry leader in introducing

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: WS/WD MODELS 036-360 WATER-TO-WATER HEAT PUMPS Unit Tag Model Number Revision: A 20D214-11NN

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

AFFORDABLE RENEWABLE CLEAN

AFFORDABLE RENEWABLE CLEAN Specification atalog GEOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN Aston Series Indoor Split Table of ontents General Introduction... 4 Model Nomenclature... 5 AHI Data... 6-7 Design Features..................................................................8

More information

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open

More information

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications CDI series Model TW Residential to Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options and Control Options Standard Features White Pre-Painted Sheet

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY SPEIFIATION ATALOG GEOTHEMAL/WATE SOUE INDOO SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL APAITY Table of ontents Introduction... 4 Model Nomenclature.... 5 AHI Data... 6-7 Design Features...

More information

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GV Series Geothermal/Water Source

More information

Envision Indoor Split Specification Catalog

Envision Indoor Split Specification Catalog Envision Series Geothermal Indoor Split Heat Pumps -410A efrigerant 2 thru 6 Ton Single Speed 2 thru 6 Ton Dual apacity Design Features Factory Options Accessories Dimensional Data Physical Data Performance

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GS Performance Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.4-4.5 COP, 15.4-26.4 EER (Closed Loop) S 3.9-5.1 COP, 19.2-30.5 EER (Open

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16 ABO BASE SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZB 03/16 Model Nomenclature 1 2 2 3-5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20-21 22 Z B V 036 T L 0 0 0 A N A N

More information

Specification Manual

Specification Manual Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

ENGINEERING SPECIFICATIONS:

ENGINEERING SPECIFICATIONS: Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS VS/VT 006-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GZ Infinityr Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.3-4.6, 14.8-28.8 (Closed Loop) S 3.8-5.2, 19.2-29.1 (Open Loop) S Optional

More information

BP/CP SeriEs. High Efficiency Heat Pumps

BP/CP SeriEs. High Efficiency Heat Pumps BP/CP SeriEs High Efficiency Heat Pumps 12 Models from ½ through 6 tons Horizontal and Vertical Configurations High Efficiency Heat Pump Duty Scroll and Rotary Compressors Floating Base Pan for Quiet Operation

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

Product Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps

Product Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps Product Data 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps 1/ 2 to 6 Nominal Tons TM Carrier s Aquazone single-packaged horizontal and vertical water source heat pumps

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS NORDIC RH-55-HACW-P-1T-*-SDE*F Horizontal Two-Stage R410a Model Size 55 (Nominal 4 Ton) Reversing (Heating AND Cooling) Domestic Hot Water (desuperheater) 230-1-60VAC Liquid

More information

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 500O11 Outdoor Split eothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 ontractor: 5 Series 500O11 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY OUTDOO SPLIT EOTHEMAL HEAT PUMPS DUAL APAITY MODELS: YAST026-072 (2 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating. EMIP60 ISO EM Series, Inch Pounds 60 Hz EM007360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: 81402 Changed EM170/240HZ dwg 31103 Changed HZ dwg to

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY EOTHEMAL HEAT PUMPS DUAL APAITY OMBINATION MODELS: YAT038-07 (3 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18 ABO OMPAT SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZ 08/18 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21-22 23 Z B V 036 T L 0 0 0 A N A

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

GT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

GT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GT Series High Efficiency Geothermal/Water Source Step- Heat Pump R-410A The GT Series Geothermal/Water Source Heat

More information

Product Catalog. Water Source Heat Pump Axiom High Efficiency Rooftop GER 3to10Tons 60Hz WSHP-PRC021F-EN. October 2017

Product Catalog. Water Source Heat Pump Axiom High Efficiency Rooftop GER 3to10Tons 60Hz WSHP-PRC021F-EN. October 2017 Product Catalog Water Source Heat Pump Axiom High Efficiency Rooftop GER 3to10Tons 60Hz October 2017 WSHP-PRC021F-EN Introduction If a rooftop water-source heat pump is in your building s future,trane

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)

More information

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A Geo-Trio High Efficiency Geothermal/Water Source Step- Heat Pump R-410A Ground Water Application: Water Temp to Ground Loop Application: Temp Range to The Bard Geo-Trio Geothermal/Water Source Heat Pump

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

WE MAKE INDOOR AIR BETTER

WE MAKE INDOOR AIR BETTER WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED APPROVED AS NOTED: NOT APPROVED PLEASE RESUBMIT

EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED APPROVED AS NOTED: NOT APPROVED PLEASE RESUBMIT EQUIPMENT TECHNICAL SUBMITTAL FOR APPROVAL DATE SUBMITTED MMVE PROJECT HVAC CONSULTING ENGINEER EQUIPMENT MANUFACTURER AIR HANDLING UNIT : MODEL : TYPE : QUANTITY : TOTAL COOLING : BTU SENSIBLE COOLING

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SPECIFICATION CATALOG LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement,

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information