FHP s EnviroSaver the best investment for your environment and home.
|
|
- Lenard Shaw
- 5 years ago
- Views:
Transcription
1 EnviroSaver The two-stage EnviroSaver from FHP provides you with a unit that will suit your budget while incorporating innovative technology for reduced energy costs. FHP was the industry leader in introducing ozone friendly refrigerants into our product line. The EnviroSaver with Copeland s UltraTech two stage scroll compressor and an ECM blower motor represents another first for FHP. Specifically designed for Geothermal applications, the EnviroSaver uses the earth's energy to heat and cool your home with savings of up to 60% on your utility bills when compared to conventional systems. You want the very best for your home and the environment. FHP s two stage EnviroSaver Series will provide a unit to meet your expectations.
2 FHP S TWO STAGE EnviroSaver goes beyond industry standards to bring you our highest efficiency unit together with the benefits of the new generation of environmentally friendly refrigerant. A heat pump operates at full load conditions less than 60 percent of the time so it is only logical to have a unit that can match this load profile. The EnviroSaver features Copeland s UltraTech Two Stage Unloading Scroll Compressor which, when controlled by a multistage thermostat, stages the compressor to match the actual demand for heating and cooling. The result lower energy bills, increased comfort and better humidity control. ADVANCED TECHNOLOGY Copeland s UltraTech unloading compressors take scroll technology to the next level while preserving the simplicity in design and reliability of a scroll compressor. In addition to the UltraTech scroll compressor the EnviroSaver is equipped with an ECM (Electronically Commutated Motor) fan motor. This motor is factory programmed to vary the airflow based on the stages of compressor operation resulting in additional energy savings and a greater level of comfort in the living space. What this means to you are lower electric utility bills for heating and cooling. GEOTHERMAL READY All FHP EnviroSaver units come ready for operation in a geothermal application. Using the earth s energy to heat and cool your home is not only good for the environment but can result in savings of 60 percent or more over conventional heating and cooling systems. Increase your energy savings with an internally mounted heat recovery system providing much of your hot water needs at virtually no additional operating costs. QUIET OPERATION ECM fan motors and the UltraTech s compressor s remarkably quiet operation, up to four times quieter than a comparable reciprocating compressor, combine to give you a unit with truly whisper quiet operation. ENVIRONMENTALLY FRIENDLY Refrigerant R-410A, the industries choice as a replacement for refrigerant R-22, preserves the earth s fragile ozone layer and assures you of availability of supply for the life of the unit. Geothermal operation contributes to a cleaner environment without the need for an unsightly outside unit. Do not be caught with high service charges once refrigerant R-22 has been phased out and is in short supply. FHP QUALITY Electro coated evaporator coils together with a Galvalume Plus finish and FHP s thirty years experience are your assurance of a quality product. FHP s EnviroSaver the best investment for your environment and home. FHP Manufacturing Company 601 NW 65th Court Fort Lauderdale, FL
3 ES SERIES TWO STAGE heat pumps O ur two stage EnviroSaver Series goes beyond industry standards to bring you high efficiency together with the benefits of the new generation of environmentally friendly refrigerants. A heat pump operates at full load conditions less than 60 percent of the time so its only logical to have a unit that can match the load profile. FHP s EnviroSaver features Copeland s UltraTech Two Stage Unloading Scroll Compressor which, when controlled by a multistage thermostat, stages the compressor to match the demand for heating and cooling. The result: lower energy bills, increased comfort and better humidity control. In addition to the UltraTech Scroll Compressor, the EnviroSaver is equipped with an ECM (Electronically Commutated Motor) fan motor. This motor is factory programmed to vary the airflow based on the stages of compressor operation resulting in additional energy savings and a greater level of comfort in the living space. Both the UltraTech Scroll Compressor and ECM fan motor have been engineered for reduced sound making this the quietest unit on the market today. All FHP EnviroSaver units come ready for operation in a geothermal application. Geothermal installations are the most cost-effective and energy efficient heating and cooling systems available today. Increase your energy savings with an internally mounted heat recovery system providing much of your hot water needs at virtually no additional operating cost. Cost Effective Up to 60% savings are possible using FHP s ES EnviroSaver Series in a geothermal application. Additional investment costs are more than offset when energy costs savings are considered. The system s long life and low maintenance help reduce the overall life cycle costs. Environmentally Friendly FHP is the industry leader in the development of the environmentally friendly technology that is designed into the EnviroSaver Series. Using Refrigerant R-410A gives you protection from potentially skyrocketing maintenance costs associated with obsolete refrigerants. FHP Quality and Reliability FHP s EnviroSaver Series feature coated evaporator coils and stainless steel drain pans as standard to ensure long trouble free life of the units. Rigorous factory testing of each unit ensures trouble free operation from the start while FHP s thirty years of experience in heat pumps are your assurance of a state of the art quality product. ISO 9001:2000 Certified
4 ES SERIES TWO STAGE HORIZONTAL VERTICAL COUNTERFLOW DIMENSIONS VERTICAL/C. FLOW HORIZONTAL MODEL WIDTH DEPTH HEIGHT WIDTH LENGTH HEIGHT A B C D E F ES025, ES ES ES All ratings & specifications are subject to change without notice. ARI / ISO PERFORMANCE DATA ENTERING WATER TEMPERATURES Water Loop Ground Loop Ground Water MODEL CFM 86 F 68 F 77 F 32 F 59 F 50 F CAPACITY AND EFFICIENCY DATA COOLING COOLING COOLING CAPACITY EER CAPACITY COP CAPACITY EER CAPACITY COP CAPACITY EER CAPACITY COP (WLHP) (WLHP) (WLHP) (WLHP) (GLHP) (GLHP) (GLHP) (GLHP) (GWHP) (GWHP) (GWHP) (GWHP) ES025 Part Load , , , , , , Full Load , , , , , , ES035 Part Load , , , , , , Full Load , , , , , , ES049 Part Load , , , , , , Full Load , , , , , , ES061 Part Load , , , , , , Full Load , , , , , , ES071 Part Load , , , , , , Full Load , , , , , , Tabulated performance data is at noted entering water temperatures and entering air conditions of 80.6 F DB/66.2 F WB at ARI/ISO rated CFM ENERGY STAR RATED 601 N.W. 65TH COURT FT. LAUDERDALE, FL PHONE: (954) FAX: (800) heat pumps Rev. 11/08
5 GUIDE SPECIFICATIONS ES Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter Laboratories (UL and ULc) listed for safety on all models. Each unit shall be run tested at the factory. Each unit shall be pallet mounted and stretch wrapped. The units shall be manufactured in an ISO9001:2000 certified facility. The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of i) in the case of residentially sold units having the last digit of the serial number as a 'T'; five years on all parts and 10 years on the refrigerant circuit components ii) on all other units; five years on the compressor and one year on all other parts. The units shall be designed to operate with entering fluid temperatures between 50 F (10 C) and 110 F (43.3 C) in cooling and temperatures between 25 F (-3.9 C) and 80oF (27 C) in heating as manufactured by FHP Manufacturing in Fort Lauderdale, Florida. CASING & CABINET The cabinet shall be fabricated from heavy-gauge steel finished with Galvalume plus, an aluminum-zinc alloy with a clear acrylic coating for additional corrosion protection. The interior shall be insulated with ½ (12.7mm) thick, multi density, coated, glass fiber. All units shall allow sufficient service access to replace the compressor without unit removal. One blower and two compressor compartment access panels shall be removable with supply and return ductwork in place. A duct collar shall be provided on the supply air opening. A filter rack with 1" (25.4mm) thick disposable filters and a 1" (25.4mm) return air duct collar shall be provided with each unit. The units shall have an insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise, and to permit service testing without air bypass. Units shall have a stainless steel condensate drain pan. REFRIGERATION CIRCUITS All units shall contain a sealed refrigerant circuit including a hermetic two stage scroll compressor, bi-directional thermal expansion valve metering device, finned tube air-to-refrigerant heat exchanger, refrigerant reversing valve and service ports. Compressor shall be high efficiency scroll type, designed for heat pump duty, quiet operation and mounted on rubber vibration isolators. Compressor motors shall be equipped with overload protection. Refrigerant reversing valves shall be pilot operated sliding piston type with replaceable encapsulated magnetic coils energized only during the cooling cycle. The finned tube coil shall be constructed of lanced aluminum fins not exceeding fourteen fins per inch bonded to rifled copper tubes in a staggered pattern not less than three rows deep and have a 450 PSIG (3100 kpa) working pressure. Coils shall have a baked polyester enamel coating for protection against most airborne chemicals. Coil end plates shall be aluminum. The coaxial water-to-refrigerant heat exchanger shall be constructed of a convoluted copper (optional cupronickel) inner tube and steel outer tube with a designed refrigerant working pressure of 450 PSIG (3100 kpa) and a designed water side working pressure of no less than 400 PSIG (2750 kpa). The water-to-refrigerant heat exchanger shall be insulated to prevent condensation at low fluid temperatures. FAN MOTOR & ASSEMBLY The fan shall be direct drive centrifugal forward curved type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low velocity operation. The fan housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the fan motor. The fan motor shall be an ECM-2 microprocessor controlled DC type motor with internal programming factory set for the specific unit and featuring soft start/stop and a delay off feature for maximum efficiency and quiet operation. Air flow rates shall be varied according to the staging of the unit. There will further be provisions for adjusting the air delivery of the motor and blower by +/- 15% from rated air flow. ELECTRICAL Controls and safety devices will be factory wired and mounted within the unit. Controls shall include compressor contactor, 24V transformer, reversing valve coil and solid state lock-out controller (UPM). The UPM controller shall include the following features: diagnostic LED's, low pressure bypass time delay (to prevent nuisance low pressure lockouts during operation with low fluid temperatures), anti short cycle time delay, random start time delay and one time intelligent reset. When the safety controls are activated the lock-out circuit shall reset itself the first time. If the safety controls are subsequently activated, then the lock-out circuit shall disable the compressor until it is reset at the thermostat or main circuit breaker to prevent compressor operation during fault conditions. A lock-out indicating terminal shall be provided in the low voltage circuit. Safety devices include a low pressure cutout set a 40 PSIG (280 kpa) for loss of charge protection (freezestat and/ or high discharge gas temperature sensor is not acceptable) and a high pressure cutout control set at 600 PSIG (4100 kpa). The ECM motor interface board shall provide a screw type terminal block for thermostat connection, LED's to indicate thermostat status and air delivery. It shall also provide a means of changing the motor program to any of up to four pre-programmed options. Direct wiring of the motor control harness to the thermostat is not acceptable. A terminal block with screw terminals shall be provided for control wiring. An optional condensate overflow device shall be factory installed to stop compressor operation if drain pan overflow is imminent. An optional energy management relay to allow unit control by an external source shall be factory installed. PIPING Supply, return water and condensate drain connections shall be brass female pipe thread fittings and mounted flush to cabinet exterior. INTERNAL ELECTRIC HEAT 208/ volt units shall be equipped with optional factory installed internal electric resistance heat for auxiliary and emergency heat. Electric heater must be Underwriter's Laboratories (UL and ULc) approved for safety when installed in the unit. External heater packages or heater packages not specifically listed for use with the unit are unacceptable. Electric heater packages shall include a heater collar mounted to the blower outlet, individual thermal overload protected heater elements no greater than 5kW each and magnetic contactors. er packages shall have a separate power supply connection from the compressor and this power supply shall also power the unit blower motor and control transformer for safe operation. HEAT RECOVERY PACKAGE 208/230 volt units shall be equipped with a optional factory installed internal heat recovery kit for domestic hot water production. This kit shall include an internally protected pump, double walled coaxial waterto-refrigerant heat exchanger, 140 F (60 C) hot water temperature limit switch and an on/off switch/circuit breaker. LOOP PUMP PACKAGE - CONSULT FACTORY 208/ volt units shall be equipped with an optional factory installed ground loop pump kit. This kit shall include a 1/6 HP loop pump, isolation valves and a set of purge connections for purging and pressurizing the ground loop with the unit in place. The pump, all piping and valves shall be internal to the unit. ESSPECS.INDD REV: 10-06
6 FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL Phone: (954) Fax: (800) ES Two Stage Series Vertical Dimensions A B C D E F G H J K M N P Q Condenser Recommended MODEL R/A Duct R/A Duct Filter Rack Water Replacement Width Depth Height Flg Width Flg Height Height Connections Nominal Filter Size ES025, /4" F.P.T. 24 X 24 X 1 ES " F.P.T. 24 X 30 X 1 ES " F.P.T. 24 X 30 X 1 ES " F.P.T. 16 X 30 X 1 (2) Left Hand Return ESVTDGIP INT II.P65 REV: Right Hand Return (FRT) (FLT) NOTES: All dimensions within +/ ". All condensate drain connections are 3/4" FPT. All Recovery Kit connections are 1/2" FPT. Internal electric heat available on /1/60 top discharge units only Internal Recovery Kit available on volt units only. Specifications subject to change without notice.
7 FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL Phone: (954) Fax: (800) ES Two Stage Series Horizontal Dimensions A B C D E F G H J K M N P Q R T Condenser Recommended MODEL R/A Duct Filter Rack R/A Duct Water Replacement Width Depth Height Flg Width Height Flg Height Connections Nom. Filter Size ES025, /4" F.P.T. 18 X 30 X 1 (1) ES " F.P.T. 18 X 20 X 1 (2) ES " F.P.T. 18 X 20 X 1 (2) ES " F.P.T. 20x24x1 (2) Left Hand Return End Blow (FLE) Left Hand Return Straight Through (FLS) Left Hand Return Right Hand Return Right Hand Return End Blow (FRE) Right Hand Return Straight Through (FRS) NOTES: All dimensions within +/ ". All condensate drain connections are 3/4" FPT. All Recovery connections are 1/2" FPT. Internal electric heat available on volt units only Internal Recovery Kit available on volt units only. Units can be field converted between end blow and straight through supply air configurations. Specifications subject to change without notice. EVHZDGIP.P65 REV: 6-07
8 FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL Phone: (954) Fax: (800) ES Two Stage Series Counterflow Dimensions A B C D E F G H J K M N P Condenser Recommended MODEL R/A Duct R/A Duct Filter Rack Water Replacement Width Depth Height Opening Opening Flg Width Flg Height Height Connections Nominal Filter Size ES025, /4" F.P.T. 24 X 24 X 1 ES " F.P.T. 24 X 30 X 1 ES " F.P.T. 24 X 30 X 1 ES " F.P.T. 16 X 30 X 1 (2) ESCFDGIP INT II.P65 REV: Left Hand Return (FLB) Right Hand Return (FRB) NOTES: All dimensions within +/ ". All condensate drain connections are 3/4" FPT. All Recovery Kit connections are 1/2" FPT. Internal electric heat available on /1/60 bottom discharge units only Internal Recovery Kit available on volt units only. Specifications subject to change without notice.
9 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / Norm ISO CERTIFIED PERFORMANCE DATA Rated at 500 CFM and 6.0 GPM Cooling ing Cooling ing Cooling ing 18, , , , , , CAPACITY DATA - PART LOAD COOLING All performance at 500 CFM and 6.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES025.1IP60 Rev: 9-05 F to F 30 o 30 o 30 o ES / x 7 DD Scroll 290 lbs 315 lbs
10 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / Norm ISO CERTIFIED PERFORMANCE DATA Rated at 800 CFM and 6.0 GPM Cooling ing Cooling ing Cooling ing 26, , , , , , CAPACITY DATA - FULL LOAD COOLING All performance at 800 CFM and 6.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES025.2IP60 Rev: 9-05 F to F 30 o 30 o 30 o ES / x 7 DD Scroll 290 lbs 315 lbs
11 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm 800 ISO CERTIFIED PERFORMANCE DATA Rated at 800 CFM and 9.0 GPM Cooling ing Cooling ing Cooling ing 24, , , , , , CAPACITY DATA - PART LOAD COOLING All performance at 800 CFM and 9.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES035.1IP60 Rev: / x 7 DD Scroll 290 lbs 315 lbs F to F 30 o 30 o 30 o ES
12 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm ISO CERTIFIED PERFORMANCE DATA Rated at 1200 CFM and 9.0 GPM Cooling ing Cooling ing Cooling ing 36, , , , , , CAPACITY DATA - FULL LOAD COOLING All performance at 1200 CFM and 9.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES035.2IP60 Rev: o 30 o 30 o F to F ES / x 7 DD Scroll 290 lbs 315 lbs
13 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm ISO CERTIFIED PERFORMANCE DATA Rated at 1000 CFM and 12.0 GPM Cooling ing Cooling ing Cooling ing 34, , , , , , CAPACITY DATA - PART LOAD COOLING All performance at 1000 CFM and 12.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES049.1IP60 Rev: o 30 o 30 o F to F ES / x 8 DD Scroll 318 lbs 348 lbs
14 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm ISO CERTIFIED PERFORMANCE DATA Rated at 1600 CFM and 12.0 GPM Cooling ing Cooling ing Cooling ing 48, , , , , , CAPACITY DATA - FULL LOAD COOLING All performance at 1600 CFM and 12.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES049.2IP60 Rev: F to F / x 8 DD Scroll 318 lbs 348 lbs o 30 o 30 o ES
15 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm ISO CERTIFIED PERFORMANCE DATA Rated at 1400 CFM and 14.0 GPM Cooling ing Cooling ing Cooling ing 42, , , , , , CAPACITY DATA - PART LOAD COOLING All performance at 1400 CFM and 14.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES061.1IP60 Rev: o 30 o 30 o F to F ES / x 9 DD Scroll 390 lbs 415 lbs
16 Electrical Elect. Compressor Loop Pump Min. Max. 208/ / / / / Note: 460 Volt Units (-4) Require Both Ground and Neutral Wires Norm ISO CERTIFIED PERFORMANCE DATA Rated at 2000 CFM and 14.0 GPM Cooling ing Cooling ing Cooling ing 60, , , , , , CAPACITY DATA - FULL LOAD COOLING All performance at 2000 CFM and 14.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES061.2IP60 Rev: o 30 o 30 o F to F ES / x 9 DD Scroll 390 lbs 415 lbs
17 Electrical Elect. Compressor Loop Pump Min. Max. 208/ Norm ISO CERTIFIED PERFORMANCE DATA Rated at 1400 CFM and 18.0 GPM Cooling ing Cooling ing Cooling ing 51, , , , , , CAPACITY DATA - PART LOAD COOLING All performance at 1400 CFM and 18.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD ES071.1IP60 Rev: o 30 o 30 o F to F ES / x 9 DD Scroll 450 lbs 495 lbs
18 Electrical Elect. Compressor Loop Pump Min. Max. 208/ Norm ISO CERTIFIED PERFORMANCE DATA Rated at 2200 CFM and 18.0 GPM Cooling ing Cooling ing Cooling ing 72, , , , , , CAPACITY DATA - FULL LOAD COOLING All performance at 2200 CFM and 18.0 GPM Sensible db 61 o wb 75 o db 63 o wb db 67 o wb db 71 o wb F to F protection and magnetic contactors (208/230-1-nly) optional UL approved internal Recovery Package and/or Ground Performance based on ARI/ISO rated air flow, fluid flow and voltage.for conditions other than rated, consult the FHP EAD ES071.2IP60 Rev: o 30 o 30 o F to F ES / x 9 DD Scroll 450 lbs 495 lbs
GUIDE SPECIFICATIONS CE Series Two Stage R-410A
GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall
More informationGUIDE SPECIFICATIONS. ES Series R-410A
GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter
More informationEMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.
EMIP60 ISO EM Series, Inch Pounds 60 Hz EM007360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: 81402 Changed EM170/240HZ dwg 31103 Changed HZ dwg to
More informationGUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers
GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationProduct Data. S Two-stage scroll compressor S Variable speed blower motor Control
GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationCDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications
CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationSi Series Model CE Residential Geothermal Heat Pump
Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,
More informationCDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications
CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationBP/CP SeriEs. High Efficiency Heat Pumps
BP/CP SeriEs High Efficiency Heat Pumps 12 Models from ½ through 6 tons Horizontal and Vertical Configurations High Efficiency Heat Pump Duty Scroll and Rotary Compressors Floating Base Pan for Quiet Operation
More informationLV MODEL. LV Model Water Source Heat Pump. 1/2 to 6 ton
boschheatingandcooling.com 1 LV Model Water Source Heat Pump 1/2 to 6 ton The option-rich, water-to-air LV offers one of the smallest cabinets in the industry, making it a great choice for replacement
More informationProduct Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control
GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationSerenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.
Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3
More informationSPLIT SYSTEMS. Air Handling Unit. Condensing Section
SPLIT SYSTEMS Air Handling Unit Condensing Section EC Series Split Systems Condensing Sections Dimensions ISO 13256-1 Certified Performance MODEL L W H Water WLHP Cooling WLHP Heating GWHP Cooling GWHP
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationTranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]
Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationGT-PX SPLIT (50YDS) SERIES. Carrier Geothermal Heat Pump Systems GT-PXS 1. All Products Technical Guide:
Carrier Geothermal Heat Pump Systems GT-PX SPLIT (50YDS) SERIES TWO-STAGE INDOOR SPLIT PURON SYSTEMS SIZES 026-064 [7.0-19.3 kw] All Products Technical Guide: 2006-2007 1 GT-PX Split (50YDS) Series Table
More informationMERIT Series R-410A - Upflow / Horizontal - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0
More informationDAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower
E N G I N E E R I N G D A T A A I R H A N D L E R S C31MV DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable lower ulletin No. 210107 July 2007 Supersedes January 2007 Nominal Capacity 3 to 5 Tons
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationMcQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog
Catalog 1100-6 McQuay Enfinity TM Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060 Model FCV & FCW Vertical Floor Size 007 060 Table of Contents
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationEnhanced Air Conditioning
4SCU16LT Split System Enhanced Air Conditioning COMPRESSOR High-efficiency 2 stage Copeland UltraTech TM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationSINGLE PACKAGE HEAT PUMPS
SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections
More informationEngineering Data Submittal Manual
Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS HT 024-060 HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS 20D214-06NN 20D214-06NN
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationLiebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller
DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationProduct Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control
GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional
More informationSpecification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationGT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A
Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GT Series High Efficiency Geothermal/Water Source Step- Heat Pump R-410A The GT Series Geothermal/Water Source Heat
More informationEngineering Data Submittal Manual
Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model
More information4SHP18LS. Product Specifications. 18 SEER Split System Enhanced Heat Pump COMPONENTS COMPRESSOR CABINET DESIGN WARRANTY COIL
Product Specifications 18 SEER Split System Enhanced Heat Pump Form No. -100 (02/2013) Communicating Thermostat enabled COMPRESSOR High-efficiency 2 stage Copeland Ultra Tech scroll compressor R410a refrigerant
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationAIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION
FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS NORDIC RH-55-HACW-P-1T-*-SDE*F Horizontal Two-Stage R410a Model Size 55 (Nominal 4 Ton) Reversing (Heating AND Cooling) Domestic Hot Water (desuperheater) 230-1-60VAC Liquid
More informationSCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS
SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More information10AC DIPLOMAT SERIES RFC SYSTEMS
10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA
More informationResidential Packaged Geothermal Heat Pump
ENGIneering Design Guide Residential Packaged Geothermal Heat Pump HP Series 1 1 /2 to 5 Tons Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Engineering
More informationHS22 Bulletin # November 1992 Supersedes September 1990
ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings
More informationGeothermal Heat Pump Systems
SUBMITTAL DATA Geothermal Heat Pump Systems Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DATA Cooling Capacity BTUH EER Heating Capacity BTUH COP Model HTS 024-060 60 Hz R-410A Ambient
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationGV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A
GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to GV Series Geothermal/Water Source
More informationHS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin
More informationBC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)
BCAHSG-2 3-Jun BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) 5 YEAR WARRANTY see warranty form for details Contents: Page Number Product Features 2
More informationSUBMITTAL COVER SHEET
SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.
More informationS/T Ratio. Input BTU/h
SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More information4SHP18LS PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS 18 SEER SPLIT SYSTEM ENHANCED HEAT PUMP FORM NO. -100 (06/2014) COMPONENTS Full metal louvered panels remove for easy coil cleaning and service Bi-directional filter drier for long-lasting
More informationSPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with
More information14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON
14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech
More informationHEAT CONTROLLER, INC. HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps
HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100
More informationGeo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A
Geo-Trio High Efficiency Geothermal/Water Source Step- Heat Pump R-410A Ground Water Application: Water Temp to Ground Loop Application: Temp Range to The Bard Geo-Trio Geothermal/Water Source Heat Pump
More informationSpecification Manual
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling
More informationProduct Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps
Product Data 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps 1/ 2 to 6 Nominal Tons TM Carrier s Aquazone single-packaged horizontal and vertical water source heat pumps
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationSUBMITTAL COVER SHEET
SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationVAV SELF CONTAINED UNITS
Energy Wise HVAC Equipment MANUAL APPLICATION FHP MANUFACTURING 601 N.W. 65th Court Fort Lauderdale, FL 33309 (954) 776-5471 (800) 776-5529 Fax www.fhp-mfg.com TABLE OF CONTENTS Overview...1 GENERAL INFORMATION
More informationR8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS R8HE Series Rev A Single-Phase and Three-Phase 95% AFUE Condensing Exchanger offering Two-Stage ing and 14 SEER Single-Stage Cooling with ECM Blower These single packaged gas/electric
More information