GENERAL ELECTRIC SINGLE PACKAGED ROOF TOP AIR CONDITIONERS

Size: px
Start display at page:

Download "GENERAL ELECTRIC SINGLE PACKAGED ROOF TOP AIR CONDITIONERS"

Transcription

1 GENERAL ELECTRIC SINGLE PACKAGED ROOF TOP AIR CONDITIONERS APT Series APT036 - APT360 3 TR thru 30 TR 10 thru 105 GE_APT_Series.indd 1 3/26/12 2:53 PM

2 4 GE_APT_Series.indd 4 3/26/12 2:54 PM

3 CONTENTS Model decoding 6 Blower drive options 7 Standard specifications/options/accessories 7-10 Physical data Selection procedure 13 Cooling capacities Electrical data Fan performance data Sound level data Unit dimensions Controls and sequence of operation 36 Typical schematic wiring diagram Continuing research results in steady improvements. Therefore, these specifications are subject to change without notice 5 GE_APT_Series.indd 5 3/26/12 2:54 PM

4 MODEL DECODING MODELS: APT036 - APT060 (DIRECT DRIVE MOTOR) 1, 2 & 3 BASIC APT PACKAGED UNIT 4, 5 & 6 NOMINAL COOLING CAPACITY (MBH) ELECTRICAL SUPPLY ( V-Ph-Hz ) L : 380/ (4 WIRE ) 8 REFRIG- ERANT CIRCUIT S : SINGLE 9 BLOWER MOTOR W : 0.75 HP OD P (DIRECT DRIVE) W : 0.75 HP OD P (DIRECT DRIVE) Y : 1 HP ODP (DIRECT DRIVE) 10 DRIVE OPTIONS N : D IREC T DRIV E 11 HEATER OPTIONS (/STAGE) N : N O HEATER A : 5/1 B : 6/1 C : 7.5/1 D : 10/2 E : 12/2 12 EVAPORATOR COIL J : I GT + ALUMINUM FI N K : IGT + MHG FIN L : I GT + COPPER FI N M : A LUMINU M FINS WITH TG. N : C OPPER FINS WITH TG. 13 CONDENSER COIL J : I GT + ALUMINUM FI N K : IGT + MHG FI N L : I GT + COPPER FI N M : A LUMINU M FINS WITH TG. N : C OPPER FINS WITH TG. 14 PDS OPTION N : S TD. UNIT P :PDS OPTION S : S IGHT GLAS S G : P & S 15 ELECTRICAL OPTIONS N : S TD. UNIT I : ANTI-ICE U :UVM V : V OLT FREE CONTACTS K :ADJ. PRESSURE SWIH A : I & U B : I & V C :U & V D : I, U & V E : I, U & K F : I, V & K G : U, V & K H : I, U, V & K J : I & K L : V & K M :U & K 16 UNIT ACCESSORIES N : S TD. UNI T C : S TD. UNI T WITH FRESH AIR HOOD & MANUA L DAMPER 17 FILTER OPTIONS A : 1 " THIC K ALUMINUM B : 2 " THIC K ALUMINUM 18 THERMOSTAT OPTION S : UNIT WITH THERMO - STAT D :UNIT WITHOU T THERMO - STAT NOTE: Volt free contact option is available as: A) Unit ON/TRIP indication, B) Compressor RUN/TRIP indication, C) Blower motor RUN/TRIP indication. MODELS: APT075 - APT360 (BELT DRIVEN MOTOR) 1, 2 & 3 BASIC APT PACKAGED UNIT 4, 5 & 6 NOMINAL COOLING CAPACITY (MBH) *** ELECTRICAL SUPPLY ( V-Ph-Hz ) L : 380/ (4 WIRE ) 8 REFRIG- ERANT CIRCUIT S : SINGLE D : DUA L 9 BLOWER MOTOR C : 1.5 HP OD P D : 2 HP OD P D : 2 HP OD P E : 3 HP OD P F : 3 HP TEFC G : 5 HP OD P H : 5 HP TEFC J : 7.5 HP ODP K : 7.5 HP TEFC J : 7.5 HP ODP K : 7.5 HP TEFC L : 1 0 HP OD P M : 1 0 HP TEFC 10 DRIVE OPTIONS J : ALT. I K : ALT. II 11 HEATER OPTIONS (/STAGE) N : N O HEATER A : 5/1* B : 6/1* C : 7.5/1 D : 10/2 E : 12/2 F : 15/2 G : 2 0 /2 N : N O HEATER C : 7.5/1 D : 10/2 E : 12/2 F : 15/2 G : 2 0 /2 H : 25/2 J : 30/2 ** 12 EVAPORATOR COIL J : I GT + ALUMINUM FI N K : I GT + MHG FI N L : IGT + COPPER FI N M : ALUMINU M FINS WITH TG. N : C OPPER FINS WITH TG. 13 CONDENSER COIL J : IGT + ALUMINUM FI N K : I GT + MHG FI N L : IGT + COPPER FI N M : ALUMINU M FINS WITH TG. N : C OPPER FINS WITH TG. 14 PDS OPTION N : S TD. UNIT P :PDS OPTION S :SIGHT GLAS S G : P & S 15 ELECTRICAL OPTIONS N : S TD. UNIT I : ANTI-ICE U :UVM V : V OLT FREE CONTACTS K : ADJ. PRESSUR E SWI H A : I & U B : I & V C :U & V D : I, U & V E : I, U & K F : I, V & K 16 UNIT ACCESSORIES N : S TD. UNIT C : S TD. UNIT WITH FRESH AIR HOOD & MANUAL DAMPER 17 FILTER OPTIONS A : 1 " THIC K ALUMINUM B : 2 " THIC K ALUMINUM 18 THERMOSTAT OPTION S : UNIT WITH THERMO - STAT D :UNIT WITHOU T THERMO - STAT 360 L : 1 0 HP OD P M : 10 HP TEFC N : 1 5 HP OD P P : 15 HP TEFC G : U, V & K H : I, U, V & K J : I & K L : V & K M :U & K NOTE: 1. Volt free contact option is available as: A) Unit ON/TRIP indication, B) Compressor RUN/TRIP indication, C) Blower motor RUN/TRIP indication. * Applicable for APT075 models only. ** Applicable for models APT180 & above only. *** 3 HP motor only available for models APT GE_APT_Series.indd 6 3/26/12 2:54 PM

5 BLOWER DRIVE OPTIONS MODEL NUMBER APT075 APT090 APT100 APT120 APT180 APT215 APT240 APT300 APT360 OPTION ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II ALT. I ALT. II HP /3 2/ /10 7.5/ RPM MOTOR PULLEY PIH DIA. (INCH) BLOWER SPEED RANGE (RPM) MINIMUM MAXIMUM PULLEY PIH DIA. (INCH) APPROX. SPEED CHANGE PER PULLEY TURN (RPM) STANDARD SPECIFICATIONS A. General Packaged cooling or combination heating and cooling units suitable for mounting on the roof or ground. The packaged unit consists of hermetic compressors, cooling coil, condenser coil, control wiring and interconnecting piping - all factory assembled and mounted on heavy gauge G-90 galvanized steel sheet press formed base, ready for field connection to utilities and ducts. The packaged unit is of rigid construction with holes provided in the base rails for overhead rigging. The unit is provided with an integral weather resistant control panel. These units are rated and tested in accordance with ARI standard 210/ ARI 360. B. Unit Enclosure Panels are of heavy gauge, G-90 galvanized steel sheet with removable access panels, completely weatherized for outdoor installation and properly reinforced and brazed. Panels and access doors are provided for inspection and access for all internal parts. Enclosures are provided with adequately reinforced points of support for setting the unit. Steel sheet panels are zinc-coated and galvanized by the hot dip process of lock forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked on electrostatic polyester dry powder coat paint, on all external panels. C. Compressor Compressors are hermetic reciprocating for APT036 - APT060 & APT090 - APT100 and hermetic scroll for all other models as standard. They are provided with all the standard controls and accessories necessary for safe operation. These are equipped with internal motor protector, factory installed crank case heater and rubber vibration isolator for quiet and efficient operation. D. Air Cooled Condensing Section 1. The air-cooled condensing section is enclosed within the unit housing and consists of condenser coil, fan(s), electric motor(s) and inherently protected compressor(s). Inner grooved copper tubes with wall thickness of inches (0.445 mm), mechanically bonded to enhanced louvered aluminum fins are standard for all condenser coils. Return bends have inch thickness (0.56 mm). As an option, corrugated copper fins or enhanced coated aluminum fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength. 2. Fans are propeller type, direct driven, upward discharge and provided with fan grille mounted on the casing. 3. Motors are totally enclosed air-over type with class F insulation. Inherent thermal protection is automatic reset type. 7 GE_APT_Series.indd 7 3/26/12 2:54 PM

6 STANDARD SPECIFICATIONS E. Evaporator Coil Section 1. All cooling coils are of enhanced fins and inner grooved copper tubes with wall thickness of inches (0.445mm), mechanically bonded to aluminum fins. Return bend has inch thickness (0.56 mm). As option, enhanced coated aluminum fins or corrugated copper fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength. 2. Drain Pan: An insulated drain Pan made of G-90 galvanized steel is provided. 3. Insulation: Insulation is supplied in adequate density and thickness for all units to prevent condensation from forming on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and erosion from air currents. F. Evaporator Fan APT036 - APT060: Evaporator fan is of a centrifugal forward-curved blade design and sized to meet system airflow/pressure using direct drive motors. These fans are statically / dynamically balanced in the fan housing during final assembly. Fan motors have ball bearings and conform to NEMA MG-1 & MG-2. Motor starters are magnetic contactor, across-theline type. APT075 - APT360: Evaporator fan is of centrifugal forward-curved blade design capable of handling total required CFM and static pressure in the low and the medium ranges. Casings are made of galvanized steel. Blower motors are of the open drip proof type (totally enclosed types are optional) and conform to NEMA MG-1 and MG-2. Fan drive is through adjustable pitch pulleys and belt driven. Blower motor is mounted on adjustable base and secured by locking device. Fan wheels shaffs and bearing are selected to operate at 25% below first critical speed. Pillow block bearings are selected for at 200,000 hours average life at design operating conditions. Shaff is turned, ground and polished from solid steel. Fans and pulleys are keyed to shaff and designed for continuous operation at maximum motor horse power and fan speed. All rotating components and assemblies are statically and dynamically balanced and every unit is vibration tested before shipment from the factory. G. Microprocessor Controller These Packaged units are provided with Performex microprocessor control board incorporating the following features: BALANCE LOADING OF COMPRESSORS: The unit s electronic control automatically operates lead/lag sequence of compressors. This is to load the compressors evenly over long periods of operation. If required however, compressor- 1 can also be set to always lead. In this case, compressor-1 always starts first and stops last. (Selectable through dip switch setting on control board). PUMP DOWN FUNCTION: In units equipped with pump down system, the controller provides the time delay between solenoid s opening and compressor starting to equalize the pressure in the system necessary for compressor to startup. (Selectable through dip switch setting on control board). COMPRESSOR ANTI-RECYCLING PROTECTION: The controller has a built-in 3 minutes minimum off timer for compressor. This is for compressor protection in case of accidental manual re-set or immediate re-cycling of thermostat due to load demand. COMPRESSOR LOCK-OUT FUNCTION: If any of the unit s safety control trips due to abnormal conditions, the electronic controls locks out the compressor affer a pre-determined timing preventing a re-start unless attended by a qualified service technician. The unit can be re-started through thermostat re-set affer ensuring safe system conditions. FAULT DIAGNOSTICS: In case of system fault, LED s on the board emits a flashing signal indicating where the fault is. This is to guide the service technician in identifying the fault. DIGITAL I/O s: The unit s control board is compatible to operate with a DDC controller or any standard 24V a.c. thermostat commercially available. SEQUENTIAL CONTROL: With input signals from the thermostat, the motors in the equipment is started in sequential order: supply fan condenser fan compressor; at a pre-determined timings. 8 GE_APT_Series.indd 8 3/26/12 2:54 PM

7 OPTIONS AND ACCESSORIES A. Electric Heaters Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or equivalent. Electrical characteristics, capacities and number of stages are as indicated. Airflow switches, fusible links and overheat limit thermostats are provided to shut-off power in case of airflow failure/overheat. Electric heater kit is installed as an externally mounted kit at the supply opening. B. UV Flow Light Emitters: The damp & dark environment inside the unit could contribute for the growth and development of hazardous bacteria and fungi. The UV flow concept uses emitter of Ultra Violet to simulate the effect of healthy sun radiation. This will inhibit the growth of these microorganism reducing in this manner mold related allergies and diseases. Breath safely with UV flow. To order UV flow use the kit number in tables below: MODEL No. APT APT075 APT APT180 APT APT KIT PART No C. Electronic Thermostat General information: Electronic thermostat shall control one or two stage heating and cooling applications. The thermostat normally displays room temperature and mode of operation. The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows you to select continuous fan operation, or have the fan on intermittent operation with the equipment. The thermostat is best located about 1500 mm (5 Ft.) above floor level, on partition a wall (not an outside wall), and should not be exposed to direct light from lamps, sun etc. It should be in return air stream, away from supply air registers/diffusers. Single/dual stage - Cooling & heating. Low voltage control - 24 VAC (nominal). Room temperature display - in 0 C or 0 F. Mode of operation - FAN/COOL/HEAT/AUTO. Fan mode - ON: Continuous fan operation; AUTO: Fan operates ON/OFF with compressor. Heating & cooling setpoint is permissible. Temperature set button - Up for increasing & down for decreasing temperature. Built-in compressor fault & clogged filter indication led lights. Remote sensing function as an option. Duct sensor is provided with the thermostat. TYPICAL THERMOSTAT Part No. Heating Stages Cooling Stages Selector Switch Positions Mode Switch Fan Switch & 2 1 & 2 OFF-HEAT/COOL ON - AUTO 9 GE_APT_Series.indd 9 3/26/12 2:54 PM

8 STANDARD FEATURES / OPTIONS / ACCESSORIES DESCRIPTION STANDARD FEATURES OPTION (FACTORY INSTALLED) ACCESSORY (FIELD INSTALLED) Horizontal discharge Compressor crankcase heaters Evaporator fan belt driven (1) Evaporator fan motor ODP type (TEFC type optional) (2) Condenser fan direct drive, propeller type Condenser fan motor totally enclosed air-over type Electric heaters Filter drier Return air filter Compressor overload protection Low pressure switch High pressure switch Cooling & heating thermostat Condenser fan guard Condenser coil guard Manual outside air damper NOTES: (1) Direct drive motors for APT036 to APT060. (2) TEFC motors are available for APT090 to APT GE_APT_Series.indd 10 3/26/12 2:54 PM

9 PHYSICAL DATA / DIRECT DRIVE MOTOR MODEL NUMBER APT036 APT048 APT060 NOMINAL C AP AC IT Y, T ONS () 3 (10.5) 4 (14) 5 (17.5) COMPRESSO R Quantity Oil (oz) R efrigerant R -22 Operating C harge (oz) C ONDE NS E R F AN T ype/drive P ropeller/direct Quantity Diameter (inch) Nominal C F M (L/S ) 3500 (1652) 3500 (1652) 3500 (1652) Motor HP R P M 1/ / / CONDENSER COIL T y pe Inner Grooved Tubes and Enhanced Fins Tube dia. - Rows - Fins per inc h 3/ / / Total face area, Sq. ft. (Sq. m.) 10.4 (0.97) 8.33 (0.774 ) 10.4 (0.97) EVAPORATOR BLOWER T ype C entrifugal S ize (inch) 10 x x x 10 Drive type Direct Drive Nominal C F M (L/S ) 1200 (566) 1600 (755) 1800 (850) Motor HP (Standard) EVAPORATOR COIL T ype Inner Grooved Tubes and Enhanced Fins Tube dia. - Rows - Fins per inc h 3/ / / Total face area, Sq. ft. (Sq. m. ) 3.82 (0.35) 3.82 (0.35) 4.86 (0.45) LOW PRESSURE SWIH Open C los e 25 ± 5 50 ± PSIG 5 PSIG HIGH PRESSURE SWIH Open 450 ± 10 PSIG C l os e 360 ± 15 PSIG R E T UR N AIR F ILT E R S (1'' THICK) Quantity S ize (inch) 2 20 x x x S HIP P ING WE IGHT K gs GE_APT_Series.indd 11 3/26/12 2:54 PM

10 PHYSICAL DATA MODEL NUMBER APT075 APT090 APT100 APT120 APT180 APT215 APT240 APT300 APT360 NOMINAL CAPACITY, TONS ( ) 6 (21) 7.5 (26) 8.5 (30) 10 (35) 15 (53 ) 18 (63 ) 20 (71 ) 25 (88) 30 (105) COMPRESSO R Quantity Oil (oz) x 2 70 x 2 60 x 2 81 & x x x x 2 R efrigerant R -22 Operating Charge per system (oz) x x x & x x x x 2 C ONDE NS E R F AN T ype/drive P ropeller/direct Qty. Diameter (inch) Nominal CFM (L/S) 5100(2410) 6600(3115) 6600(3115) 6600(3115) 11500(5430) 13400(6330) 13400(6330 ) 22300(10535 ) 22300(10535 ) Motor HP R P M 3/4 950 CInner ONDE NS E R C OIL T ype Grooved Tubes and Enhanced Fins Tube dia. - Rows - Fins per inch 3/ / / / / / / / / Total face area, Sq. ft. (Sq. m.) (1.08) 22.5 (2.1 ) 22.5 (2.1 ) 22.5 (2.1) 36 (3.36) 48 (4.5 ) 48 (4.5 ) 72 (6.71) 72 (6.71 ) E VAPOR ATOR BLOWER T ype C entrifugal Size (inch) 12 x x x x x x x x x 18 Drive type B elt Nominal CFM (L/S) 2400(1135) 3000(1415) 3400(1605) 4000(1890) 6000(2835) 7000(3305) 7500(3540) 9600(4535) 11250(5315 ) Motor HP - Std. / Alt 1.5/2 2/3 2/3 3 5/7.5 5/ /10 7.5/10 10/15 Motor Frame (NEMA) Std. / Alt. 56 / / / T/213T 184T/213T 213T/215 T 2 13T/215T 213T/254 T Fan RPM range Factory setting full turns open Fan pulley pitch dia EVAPORATOR COIL T ype Inner G rooved T ubes and E nhanced F ins Tube dia. - Rows - Fins per inch 3/ / / / / / / / / Total face area, Sq. ft. (Sq. m. ) 5.47 (0.51) 8.94 (0.83) 8.94 (0.83) 8.94 (0.83) (1.24) 16 (1.48 ) (1.64 ) (1.92 ) (1.92 ) LOW PRESSURE SWI H Open C los e 25 ± 5 50 ± PSIG 5 PSIG HIGH PRESSURE Open 450 ± 10 PSIG SWI H C los e 360 ± 15 PSIG R E T UR N AIR FILTERS (1'' THICK) Qty Size (inch) 22.5x x x x x x x 23 27x x 26.6 S HIP P ING WE IGHT K gs GE_APT_Series.indd 12 3/26/12 2:54 PM

11 SELECTION PROCEDURE 1. Determine cooling and heating capacity requirements at design conditions Data: Condenser entering air temperature : 1150F Evaporator entering air temperature : 800F DB / 670F WB Evaporator airflow : 7500 CFM Required cooling capacity : 196,000 BTUH Sensible heat capacity : 145,000 BTUH Required heating capacity : 20 External static pressure : 0.8 INCH WG. Power supply (V-Ph-Hz) : 380/ Unit selection based on required cooling capacity Enter cooling capacity performance data at condenser entering air temp. at 1150F and evaporator entering air temp. 800F DB, 670F WB, 7500 CFM airflow. The APT240 unit will give 212,660 BTUH cooling capacity (gross) and 160,310 BTUH sensible heat capacity (gross). 3. Electric heater selection Heating capacity required = 20. Enter electric heating table for APT240 at 380/ power supply. 20 heater at 380/415 volts satisfies the required heating. 4. Determine fan speed and power requirements at design conditions Before entering the fan performance tables, calculate the summation of external static pressure for the required components as follows. External static pressure : 0.8 INCH WG. Electric heater : 0.14 INCH WG 0.94 INCH WG. Enter fan performance table for APT240 model. For 7500 CFM and external static pressure of 0.94 INCH WG, it require 830 RPM and 4.58 brake horse power (BHP) wherein the standard motor will meet job requirements. 5. Determine input power to motor Use fan motor efficiency table. Blower motor watts = BHP x 746 watts = 4.58 x 746 = 4218 watts. Motor efficiency Determine net capacities Above capacities are gross and do not include blower motor heat gain. Determine net capacities as follows: Net cooling capacity = Gross cooling capacity blower motor heat = 212,660 (4218 WATTS x BTUH/WATTS) = 198,264 BTUH Net sensible capacity = 160,310 (4218 WATTS x BTUH/WATTS) = 145,914 BTUH 7. Altitude correction factors for cooling capacity ALTITUDE, FT FACTOR Total capacity Sensible capacity GE_APT_Series.indd 13 3/26/12 2:54 PM

12 COOLING CAPACITIES Model No.: APT036 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 1135/ / /0.260 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT048 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 1275/ / /0.280 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT060 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC Total Capacity (1000 Btuh) Gross SC Sensible Heat Capacity (1000 Btuh) Gross DBE Dry Bulb Temp. ( 0 F) of Air Entering Coil EVAPORATOR AIRFLOW, CFM/DR 1600/ / /0.150 EVAPORATOR ENTERING AIR, WBE ( 0 F) WBE Wet Bulb Temp. ( 0 F) of Air Entering Coil DBL Dry Bulb Temp. ( 0 F) of Air Leaving Coil WBL Wet Bulb Temp. ( 0 F) of Air Leaving Coil Total unit power input DR Wet Bulb depression ratio NOTES: 1. Direct interpolation is permissible Do not extrapolate. 2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80). 3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL [DR (DBE WBE)]. 4. Total unit power input at 0.15 ESP for APT036 & 0.2 ESP for APT048/APT GE_APT_Series.indd 14 3/26/12 2:54 PM

13 COOLING CAPACITIES Model No.: APT075 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 1900/ / /0.18 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT090 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 2400/ / /0.26 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT100 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC Total Capacity (1000 Btuh) Gross SC Sensible Heat Capacity (1000 Btuh) Gross DBE Dry Bulb Temp. ( 0 F) of Air Entering Coil EVAPORATOR AIRFLOW, CFM/DR 2700/ / /0.165 EVAPORATOR ENTERING AIR, WBE ( 0 F) WBE Wet Bulb Temp. ( 0 F) of Air Entering Coil DBL Dry Bulb Temp. ( 0 F) of Air Leaving Coil WBL Wet Bulb Temp. ( 0 F) of Air Leaving Coil Total unit power input DR Wet Bulb depression ratio NOTES: 1. Direct interpolation is permissible Do not extrapolate. 2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80). 3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL [DR (DBE WBE)]. 4. Total unit power input based on nominal CFM & 0.25 ESP. 15 GE_APT_Series.indd 15 3/26/12 2:54 PM

14 COOLING CAPACITIES Model No.: APT120 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 3200/ / /0.180 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT180 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 4800/ / /0.180 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT215 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC Total Capacity (1000 Btuh) Gross SC Sensible Heat Capacity (1000 Btuh) Gross DBE Dry Bulb Temp. ( 0 F) of Air Entering Coil EVAPORATOR AIRFLOW, CFM/DR 5800/ / /0.180 EVAPORATOR ENTERING AIR, WBE ( 0 F) WBE Wet Bulb Temp. ( 0 F) of Air Entering Coil DBL Dry Bulb Temp. ( 0 F) of Air Leaving Coil WBL Wet Bulb Temp. ( 0 F) of Air Leaving Coil Total unit power input DR Wet Bulb depression ratio NOTES: 1. Direct interpolation is permissible Do not extrapolate. 2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80). 3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL [DR (DBE WBE)]. 4. Total unit power input based on nominal CFM & 0.35 ESP. 16 GE_APT_Series.indd 16 3/26/12 2:54 PM

15 COOLING CAPACITIES Model No.: APT240 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 6000/ / /0.175 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT300 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC EVAPORATOR AIRFLOW, CFM/DR 8000/ / /0.180 EVAPORATOR ENTERING AIR, WBE ( 0 F) Model No.: APT360 CONDENSER ENTERING AIR TEMP. ( 0 F) 85 SC 95 SC 105 SC 115 SC 125 SC Total Capacity (1000 Btuh) Gross SC Sensible Heat Capacity (1000 Btuh) Gross DBE Dry Bulb Temp. ( 0 F) of Air Entering Coil EVAPORATOR AIRFLOW, CFM/DR 9600/ / /0.110 EVAPORATOR ENTERING AIR, WBE ( 0 F) WBE Wet Bulb Temp. ( 0 F) of Air Entering Coil DBL Dry Bulb Temp. ( 0 F) of Air Leaving Coil WBL Wet Bulb Temp. ( 0 F) of Air Leaving Coil Total unit power input DR Wet Bulb depression ratio NOTES: 1. Direct interpolation is permissible Do not extrapolate. 2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80). 3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL [DR (DBE WBE)]. 4. Total unit power input based on nominal CFM & 0.35 ESP. 17 GE_APT_Series.indd 17 3/26/12 2:54 PM

16 ELECTRICAL DATA MODELS: APT036 - APT060 MODEL NUMBER APT036 APT048 APT060 POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE FM COMPRES- SOR BLOWER MOTOR 380/ (4 WIRE) 380/ (4 WIRE) 380/ (4 WIRE) ELECTRIC HEATER MIN. MAX. FLA RLA LRA HP FLA FLA MCA MOCP /6 7.6/ / /20 7.5/10* 11.4/ / /30 12* /6 7.6/ / /30 7.5/10* 11.4/ / /30 12* /6 7.6/ / /30 7.5/10* 11.4/ / /30 12* LEGEND FLA Full Load Amps HP Horse Power BM Blower Motor LRA Locked Rotor Amps RLA Rated Load Amps MCA Minimum Circuit Amps MOCP Maximum Over Current Protection FM Fan Motor (Condenser) *Combination of heater modules MODELS: APT075 & APT090 POWER SUPPLY (V-Ph-Hz) 380/ (4 WIRE) DESCRIPTION VOLTAGE RANGE Min. Max. FM FLA (1.9 FOR APT090) COMPR- ESSOR BM RLA LRA HP FLA Nom APT075 APT090 ELECTRIC HEATER FLA MCA MOCP /6 7.6/ / /30 7.5/10* 11.4/ / /30 12 */15* 18.2/ / / /6 7.6/ / /30 7.5/10* 11.4/ / /30 12 */15* 18.2/ /3 3 30/35 MODEL NUMBER COMPR- ESSOR (each) BM RLA LRA HP FLA Nom ELECTRIC HEATER FLA MCA MOCP /6 7.6/9.1 24/24 30/30 7.5/10* 11.4/ /24 30/30 12 */15* 18.2/ /3 3 30/35 20* /6 7.6/ / /30 7.5/10* 11.4/ / /30 12 */15* 18.2/ / /35 20* MODELS: APT100 & APT120 POWER SUPPLY (V-Ph-Hz) 380/ (4 WIRE) DESCRIPTION VOLTAGE RANGE Min. Max. FM FLA COMPR- ESSOR (each) BM RLA LRA HP FLA Nom. APT100 APT120 ELECTRIC HEATER FLA MCA MOCP / / / / */12* 15.2/ / /35 15*/20* 22.8/ / / / / /30 40/ */12* 15.2/ /30 40/40 15*/20* 22.8/ / /45 MODEL NUMBER COMPR- ESSOR (each) BM RLA LRA HP FLA Nom ELECTRIC HEATER * FLA MCA MOCP / / / /35 10 */12* 15.2/ / /35 15*/20* 22.8/ / /45 25* / / / /40 10 */12* 15.2/ / /40 15*/20* 22.8/ / / GE_APT_Series.indd 18 3/26/12 2:55 PM

17 ELECTRICAL DATA MODELS: APT180 & APT215 POWER SUPPLY (V-Ph-Hz) 380/ (4 WIRE) DESCRIPTION VOLTAGE RANGE Min. Max. FM (each) FLA COMPR- ESSOR (each) BM RLA LRA HP FLA Nom & & APT180 APT215 ELECTRIC HEATER FLA MCA MODEL NUMBER MOCP / / /51 60/ */12* 15.2/ /51 60/60 15*/20* 22.8/ /51 60/60 25*/30* 38/ / / / / / / */12* 15.2/ / /70 15*/20* 22.8/ / /70 25*/30* 38/ / /80 COMPR- ESSOR (each) BM RLA LRA HP FLA Nom ELECTRIC HEATER FLA MCA MOCP / / / /70 10 */12* 15.2/ / /70 15*/20* 22.8/ / /70 25*/30* 38/ / / / / / */12* 15.2/ /6 0 70/70 15*/20* 22.8/ /6 0 70/70 25*/30* 38/ / /80 MODELS: APT240 & APT300 POWER SUPPLY (V-Ph-Hz) 380/ (4 WIRE) DESCRIPTION VOLTAGE RANGE Min. Max. FM (each) FLA COMPR- ESSOR (each) BM RLA LRA HP FLA Nom. APT240 APT300 ELECTRIC HEATER FLA MCA MODEL NUMBER MOCP / / / / */12* 15.2/ / /80 15*/20* 22.8/ / /80 25*/30* 38/ / / / / /63 80/ */12* 15.2/ /63 80/80 15*/20* 22.8/ /63 80/80 25*/30* 38/ / /80 COMPR- ESSOR (each) BM RLA LRA HP FLA Nom ELECTRIC HEATER FLA MCA MOCP */12* 15.2/ / / */20* 22.8/ / /100 25*/30* 38/ / /100 35*/40* 53.2/ / / */12* 15.2/ / / */20* 22.8/ / /100 25*/30* 38/ / /100 35*/40* 53.2/ / /100 MODEL: APT360 POWER SUPPLY (V-Ph-Hz) 380/ (4 WIRE) DESCRIPTION VOLTAGE RANGE Min. Max. FM (each) FLA COMPR- ESSOR (each) BM RLA LRA HP FLA Nom. MODEL NUMBER APT360 ELECTRIC HEATER FLA MCA MOCP */12* 15.2/ / / */20* 22.8/ / /110 25*/30* 38/ / /110 35*/40* 53.2/ / / */12* 15.2/ / / */20* 22.8/ / /110 25*/30* 38/ / /110 35*/40* 53.2/ / /11 0 LEGEND FLA Full Load Amps HP Horse Power BM Blower Motor LRA Locked Rotor Amps RLA Rated Load Amps MCA Minimum Circuit Amps MOCP Maximum Over Current Protection FM Fan Motor (Condenser) *Combination of heater modules 19 GE_APT_Series.indd 19 3/26/12 2:55 PM

18 FAN PERFORMANCE DATA / DIRECT DRIVE MOTOR Model No.: APT036 BLOWER MOTOR SPEED HIGH EXTERNAL STATIC PRESSURE (inch wg.) CFM BH P MEDIUM CFM BH P LO W CFM BH P Model No.: APT048 BLOWER MOTOR SPEED HIGH EXTERNAL STATIC PRESSURE (inch wg.) CF M BHP MEDIUM CF M BH P LO W CF M BH P Model No.: APT060 BLOWER MOTOR SPEED HIGH EXTERNAL STATIC PRESSURE (inch wg.) CF M BH P MEDIUM CF M BHP LO W CF M BH P NOTE: 1. Values include losses for dry coil, filter & unit casing. 2. Direct drive motors have single speed connection only. Thermostats are also single speed type only. Refer to the unit wiring diagram for connecting to other motor speeds. 20 GE_APT_Series.indd 20 3/26/12 2:55 PM

19 FAN PERFORMANCE DATA Model No.: APT075 w, CFM (L/S) 1800 (849) 2000 (944) 2200 (1038) 2400 (1133) 2600 (1227) 2800 (1321) 3000 (1416) 3200 (1510) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP I 761* 0.42* * 0.51* * 0.65* * 1.52* * 1.68* * 1.79* Values include losses for filters, unit casing and wet coils. 2. Standard 1.5 HP motor to be used for the unshaded portion. 3. Alt. 2 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. II Model No.: APT090 w, CFM (L/S) 2400 (1133) 2600 (1227) 2800 (1321) 3000 (1416) 3200 (1510) 3400 (1605) 3600 (1699) 3800 (1793) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 620* 0.65* I * 2.21* * 2.42* * 2.62* * 2.83* Values include losses for filters, unit casing and wet coils. 2. Standard 2 HP motor to be used for the unshaded portion. 3. Alt. 3 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. II Model No.: APT100 w, CFM (L/S) 2700 ( (1321) 3000 (1416) 3200 (1510) 3400 ( (1699) 3800 (1793) 4000 (1888) 4100(1935) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 610* 0.73* * 0.79* 700I II Values include losses for filters, unit casing and wet coils. 2. Standard 2 HP motor to be used for the unshaded portion. 3. Alt. 3 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. 21 GE_APT_Series.indd 21 3/26/12 2:55 PM

20 FAN PERFORMANCE DATA Model No.: APT120 w, CFM (L/S) 3200 (1510) 3400 (1605) 3600 (1699) 3800 (1793) 4000 (1888) 4200 (1982) 4400 (2076) 4600 (2170) 4800 (2265) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 685* 0.80* * 1.02* 760I * 1.16* II 1. Values include losses for filters, unit casing and wet coils. 2. Standard 3 HP motor to be used. 3. Bordered regions indicate alternative drives I & II. Model No.: APT180 w, CFM (L/S) 4800 ( ( (2454) 5400 (2548) 5600 (2643) 5800 (2737) 6000 (2832) 6200 (2926) 6400 (3020) 6600 (3115) 6800 (3209) 7000 (3303) 7200 (3398) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 698* 1.45* 755* 1.72* * 1.58* I II * 1.85* * 2.01* * 2.18* * 4.39* * 4.68* * 4.91* * 4.90* 1181* 5.22* * 5.21* 1190* 5.55* * 5.50* 1199* 5.79* * 5.60* 1178* 6.10* 1208* 6.35* * 6.10* 1198* 6.32* 1219* 6.60* * 6.21* 1210* 6.66* 1228* 7.05* 1. Values include losses for filters, unit casing and wet coils. 2. Standard 5 HP motor to be used for the unshaded portion. 3. Alt. 7.5 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. Model No.: APT215 External Static Pressure (inch wg.) w, CFM (L/S) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5800 (2737) (2832) I (2926) (3020) (3115) * 5.32* 6800 (3209) * 5.48* 7000 (3303) * 5.20* 1024* 5.62* 7200 (3398) * 5.48* 1032* 5.94* 7400 (3492) * 5.67* 1040* 6.32* 7600 (3587) * 5.98* 1048* 6.71* 7800 (3681) * 6.38* 1055* 7.20* 8000 (3775) * 6.60* 1062* 7.50* 8200 (3870) * 6.82* II Notes: 1. Values include losses for filters, unit casing and wet coils. 2. Standard 5 HP motor to be used for the unshaded portion. 3. Alt. 7.5 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. 22 GE_APT_Series.indd 22 3/26/12 2:55 PM

21 FAN PERFORMANCE DATA Model No.: APT240, CFM (L/S) 6000 (2832) 6200 ( (3020) 6600 (3115) 6800 (3209) 7000 (3303) 7200 (3398) 7400 (3492) 7600 (3587) 7800 (3681) 8000 (3775) 8200 (3870) 8400 (3964) 8600 (4058) 8800 (4152) 9000 (4247) Notes: External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 600* 2.15* 640* 2.40* * 2.30* 665* 2.65* 710I * 2.51* * 2.82* * 6.24* * 6.56* * 6.84* * 7.10* * 7.40* * 7.73* * 7.37* 1066* 8.10* * 7.51* 1074* 8.31* * 7.85* 1079* 8.52* * 7.52* 1023* 8.11* * 7.89* 1029* 8.38* * 8.20* Values include losses for filters, unit casing and wet coils. 2. Standard 7.5 HP motor to be used for the unshaded portion. 3. Alt. 10 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. II Model No.: APT300, CFM (L/S) 8000 ( (3870) 8400 (3964) 8600 (4058) 8800 (4152) 9000 (4247) 9200 (4341) 9400 (4436) 9600 (4530) 9800 (4624) (4719) (4813) (4907) (5002) (5096) (5191) (5286) External Static Pressure (inch wg.) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 641* 3.24* 695* 3.63* 735* 3.84* * 3.40* 710* 3.85* I 664* 3.51* 726* 4.13* * 3.65* 735* 4.28* * 3.78* * 4.10* * 4.32* * 8.28* * 8.52* * 9.10* II Notes: 1. Values include losses for filters, unit casing and wet coils. 2. Standard 7.5 HP motor to be used for the unshaded portion. 3. Alt. 10 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. 23 GE_APT_Series.indd 23 3/26/12 2:55 PM

22 FAN PERFORMANCE DATA Model No.: APT360, CFM (L/S) 9600 (4530) 9800 (4624) (4719) (4813) (4907) (5002) (5096) (5191) (5286) (5380) (5474) (5569) (5663) (5757) (5852) (5899) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP I * 11 84* * 2* * 7* * 11 64* 1121* * * * 4* II Notes: 1. Values include losses for filters, unit casing and wet coils. 2. Standard 10 HP motor to be used for the unshaded portion. 3. Alt. 15 HP motor to be used for the shaded portion. 4. Bordered regions indicate alternative drives I & II. * For bold figures, consult your nearest GE representative for proper selection of drives. Drives shall be field supplied & installed. 24 GE_APT_Series.indd 24 3/26/12 2:55 PM

23 SOUND LEVEL DATA To obtain Sound Pressure Level measured 5. (1.6 m) directly opposite the center of blower inlet: 1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE). SE= (CFM x TSP)/6362 x BHP (see step 4 & table below). 2. Read dba level from respective graph at operating BHP & SE(%). 3. Knowing RPM, select proper row from sound power factor table and add dba level to each values in the row to obtain Sound Power Level (db re watts). 4. Calculate TSP (Total Static Pressure) as follows: TSP = ISP + ESP ESP (External Static Pressure) from Job Specification. ISP (Internal Static Pressure) Calculate from table below. FACE VELOCITY INTERNAL STATIC PRESSURE (inch wg.) (FPM) 2 ROW 3 ROW 4 ROW NOTE: Pressure drop across filter, coil and casing are included in ISP. 25 GE_APT_Series.indd 25 3/26/12 2:55 PM

24 SOUND LEVEL DATA MODELS: APT036 - APT060 SOUND POWER FACTOR TABLE VALUES GIVE TO SOUND POWER Octave Band Center Frequency Hz RPM RPM RPM To obtain Sound Pressure Level measured 5. (1.6 m) directly opposite the center of blower inlet: 1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE). SE= (CFM x TSP)/6362 x BHP 2. Read dba level from above graph at operating BHP & SE(%). 3. Knowing RPM, select proper row from above table and add dba level to each values in the row to obtain Sound Power Level (db re watts). 26 GE_APT_Series.indd 26 3/26/12 2:55 PM

25 SOUND LEVEL DATA MODEL: APT075 SOUND POWER FACTOR TABLE VALUES GIVE TO SOUND POWER Octave Band Center Frequency Hz RPM RPM RPM RPM To obtain Sound Pressure Level measured 5. (1.6 m) directly opposite the center of blower inlet: 1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE). SE= (CFM x TSP)/6362 x BHP 2. Read dba level from above graph at operating BHP & SE(%). 3. Knowing RPM, select proper row from above table and add dba level to each values in the row to obtain Sound Power Level (db re watts). 27 GE_APT_Series.indd 27 3/26/12 2:55 PM

26 SOUND LEVEL DATA MODELS: APT090 - APT180 SOUND POWER FACTOR TABLE Octave Band Center Frequency Hz RP M VALUES GIVE TO SOUND POWER RPM RPM To obtain Sound Pressure Level measured 5. (1.6 m) directly opposite the center of blower inlet: 1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE). SE= (CFM x TSP)/6362 x BHP 2. Read dba level from above graph at operating BHP & SE(%). 3. Knowing RPM, select proper row from above table and add dba level to each values in the row to obtain Sound Power Level (db re watts). 28 GE_APT_Series.indd 28 3/26/12 2:55 PM

27 SOUND LEVEL DATA MODELS: APT215 - APT360 SOUND POWER FACTOR TABLE Octave Band Center Frequency Hz RPM VALUES GIVE TO SOUND POWER RPM RPM To obtain Sound Pressure Level measured 5. (1.6 m) directly opposite the center of blower inlet: 1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE). SE= (CFM x TSP)/6362 x BHP 2. Read dba level from above graph at operating BHP & SE(%). 3. Knowing RPM, select proper row from above table and add dba level to each values in the row to obtain Sound Power Level (db re watts). 29 GE_APT_Series.indd 29 3/26/12 2:55 PM

28 STATIC PRESSURE DROP (INCH WG.) MODELS: APT036 - APT060 COMPONENT 1 HEATER MODULE 2 HEATER MODULE CFM MODELS: APT075 COMPONENT 1 HEATER MODULE 2 HEATER MODULE CFM MODELS: APT090 - APT120 COMPONENT 1 HEATER MODULE 2 HEATER MODULE CFM MODELS: APT180 - APT240 COMPONENT 1 HEATER MODULE 2 HEATER MODULE CFM MODELS: APT300 - APT360 COMPONENT 1 HEATER MODULE 2 HEATER MODULE CFM BLOWER MOTOR EFFICIENCY MOTOR HP EFFICIENCY (% ) NOTE: Convert BHP to watts using following formula Watts = 746 BHP Motor Efficiency 30 GE_APT_Series.indd 30 3/26/12 2:55 PM

29 J UNIT DIMENSIONS / APT036 - APT075 AIR IN POWER SUPPLY INLET CONDENSER COIL AIR IN COMPRESSOR/CONTROL COMPARTMENT CONDENSATE DRAIN OUTLET [BOTH ENDS] TOP VIEW MOUNTING HOLES Ø 13 [0.5] [ 4 EACH] AIR OUT CONDENSER COIL SUPPLY AIR RETURN AIR K SUPPLY AIR OPENING RETURN AIR OPENING FRESH AIR OPENING FILTER ACCESS PANEL [BOTH ENDS] DRAIN OUTLET [BOTH ENDS] ACCESS PANEL FOR BLOWER AND MOTOR COMPRESSOR/CONTROLS ACCESS PANEL 850 [33.46] END VIEW 286 [11.27] 90 [3.53] N FRONT VIEW 51 [2.00] 15 [0.59] 61 [2.41] END VIEW MODEL DIMENSIONS A B C D E F G H J K L M N APT036 - APT (57.48) 1025(40.35) 1430(56.3) 700(27.56 ) 163(6.42) 373(14.68 ) 250(9.84) 500(19.69) 57(2.24) 304(11.96) 343(13.49) 340(13.39) 123(4.84 ) APT (69.88) 1150(45.28) 1745(68.7) 800(31.5) 175(6.89) 480(18.9) 325(12.8) 670(26.38) 80(3.15) 280(11.02) 275(10.83) 600(23.62) 51(2 ) NOTES: 1. All dimensions are in mm (dimensions in brackets are in inches). 2. Service clearance should be 1200mm (4 feet) on all sides. 31 GE_APT_Series.indd 31 3/26/12 2:55 PM

30 UNIT DIMENSIONS / APT090 - APT120 TOP VIEW END VIEW FRONT VIEW END VIEW NOTES: 1. All dimensions are in mm (dimensions in brackets are in inches). 2. Service clearance should be 1200mm (4 feet) on all sides. 32 GE_APT_Series.indd 32 3/26/12 2:55 PM

31 UNIT DIMENSIONS / APT180 TOP VIEW END VIEW FRONT VIEW END VIEW NOTES: 1. All dimensions are in mm (dimensions in brackets are in inches). 2. Service clearance should be 1200mm (4 feet) on all sides. 33 GE_APT_Series.indd 33 3/26/12 2:55 PM

32 UNIT DIMENSIONS / APT215 - APT240 TOP VIEW END VIEW FRONT VIEW END VIEW NOTES: 1. All dimensions are in mm (dimensions in brackets are in inches). 2. Service clearance should be 1200mm (4 feet) on all sides. 34 GE_APT_Series.indd 34 3/26/12 2:55 PM

33 UNIT DIMENSIONS / APT300 - APT360 TOP VIEW END VIEW FRONT VIEW END VIEW NOTES: 1. All dimensions are in mm (dimensions in brackets are in inches). 2. Service clearance should be 1200mm (4 feet) on all sides. 35 GE_APT_Series.indd 35 3/26/12 2:55 PM

34 CONTROLS & SEQUENCE OF OPERATION Scroll compressors are designed to operate in single direction only. Hence, care has to be taken to ensure correct rotation when the system is operated. Verification of correct rotation is by observing that the suction pressure drops and discharge pressure rises when compressor run. Reverse rotation results in abnormal sound, as well as, substantially low current draw and by interchanging power supply wire L1 & L3 will correct this problem. The operation of the air conditioning unit is controlled by a 24VAC electronic control board. GENERAL The thermostat normally displays room temperature and mode of operation. The five buttons on the front of the unit allow complete control of the thermostat. The thermostat also allows to select continuous fan operation (useful when using an air cleaner) or have the fan come on with the compressor. SWIH FUNCTION - On/Off Key : Switch the system On or Off. - Up Key : To increases the set temperature. - Down Key : To decreases the set temperature. - Mode Key : Changes the mode to Fan, Cool, Heat or Auto. - Fan Key : Changes the Fan Operation to Auto or Continuous. - C/ F selection : By pressing Mode & UP key together, toggles between C to F or vice versa. USER CONTROLS Mode: Select the desired mode of operation by pressing of the mode button: Fan: Cool: Heat: Auto: In this mode of operation, the compressor will be in inactive state. Display shows room temperature. Fan will be running. In this mode of operation, the compressor will be ON a er a delay depending on the differential of room temperature & Set temperature. In this mode of operation, Fan is ON. In auto mode, thermostat provide automatic changeover from heating to cooling mode & vice versa. Thermostat automatically switches to maintain the desired temperature. DIP SWIH OPTIONS AND FUNCTIONS There are 4 small DIP (Dual in line package) switches on the back of the circuit board which must be configured by the installer. DIP SWIH SELECTION SWI H O N OFF 1 N. A. - 2 N. A. - 3 N. A. - 4 INDOOR SENSOR REMOTE SENSOR Note: Keep DIP SWIH 1, 2 & 3 in OFF position only. COMP 1 COMP 2 PACU CONTROL PANEL COMPRESSOR FAULT SIGNAL (VOLT-FREE CONTACT) (COMMON) HOOK-UP WIRING DIAGRAM ( THERMOSTAT CONTROLLER TO PACKAGED UNIT ) ATB NOTE: OPTIONAL CONNECTION : IF REMOTE TEMPERATURE SENSING FUNCTION IS REQUIRED. SENSOR ( OPTIONAL CONNECTION ) THERMOSTAT (ZAC P/N ) REMOTE SENSOR FAULT 1 FAULT 2 Y2 W1 Y1 G 24V(R) 24V(C) W2 LVTB R C G Y1 Y2 W1 W2 SUPPLY FAN CONTROL STG1 COOLING STG2 COOLING STG1 HEATER STG2 HEATER 24V ac LEGEND: ATB AUXILIARY TERMINAL BLOCK LVTB LOW VOLTAGE TERMINAL BLOCK 36 GE_APT_Series.indd 36 3/26/12 2:55 PM

35 TYPICAL SCHEMATIC WIRING DIAGRAM NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items. 2. Refer to unit control box (inside panel) for exact wiring diagram. 37 GE_APT_Series.indd 37 3/26/12 2:56 PM

36 TYPICAL SCHEMATIC WIRING DIAGRAM 38 GE_APT_Series.indd 38 3/26/12 2:56 PM

37 39 GE_APT_Series.indd 39 3/26/12 2:56 PM

38 Middle East Air Conditioners Co. Ltd. Middle East Air Conditioners Co. Ltd. P.O. Box Dammam KSA Kingdom of Saudi Arabia Tel: Fax: GE_APT_Series.indd 40 3/26/12 2:56 PM

Single Packaged Roof Top Air Conditioners PY Series. PY036 - PY360 3 TR thru 30 TR 10 kw thru 105 kw. The "Comfort" Series

Single Packaged Roof Top Air Conditioners PY Series. PY036 - PY360 3 TR thru 30 TR 10 kw thru 105 kw. The Comfort Series Single Packaged Roof Top Air Conditioners PY Series PY036 - PY360 3 TR thru 30 TR 10 thru 105 The "Comfort" Series Company Business Zamil Air Conditioners was founded in 1974, and is the first major business

More information

Modular Air Handling Units BMY Series BMY020 thru BMY TR thru 95 TR 70 kw thru 334 kw R-22

Modular Air Handling Units BMY Series BMY020 thru BMY TR thru 95 TR 70 kw thru 334 kw R-22 Modular Air Handling Units BMY Series BMY020 thru BMY095 20 TR thru 95 TR 70 thru 334 R-22 Company Business Zamil Air Conditioners was founded in 1974 as one of the first air conditioning business to be

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

PACKAGE HEAT PUMP UNITS

PACKAGE HEAT PUMP UNITS PACKAGE HEAT PUMP UNITS FOM NO. PTZ-77 EV. Supersedes Form No. PTZ-77 ev. 2 Featuring Earth-Friendly -40A efrigerant earth friendly refrigerant TZCHC- SEE HIGH EFFICIENCY SEIES NOMINAL SIZES -5 TONS [0.6-7.6

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s) NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES 530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204 TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS D1EG/D1EE036, 048, & 060 3, 4, AND 5 NOMINAL TONS 11-11.5 SEER FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. GENERAL YORK Model DEE/DEG units are

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS HIEER : 3-25 Tons PRODUCT DATA BOOK Introduction Roof Top Package units have been developed & produced to provide not only the ultimate indoor comfort, but also to guarantee long

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 150 models Terminal

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

38AUM Air Cooled Condensing Units 50Hz

38AUM Air Cooled Condensing Units 50Hz 38AUM Air Cooled Condensing Units 50Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR REV. 4 Supersedes Form No. EXR Rev. 3

PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR REV. 4 Supersedes Form No. EXR Rev. 3 PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR22-845 REV. 4 Supersedes Form No. EXR22-845 Rev. 3 SKKL- STANDARD EFFICIENCY SERIES NOMINAL SIZES 6 TON [21.1 kw] (50 Hz, 3 PHASE ONLY) RATED IN ACCORDANCE

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant

38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant 38P Condensing Units 60Hz 38P 36K 60K 38P 18K 24K Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( )

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( ) Single---Packaged Air Conditioner System 2 to 5 Nominal Tons (024---060) Product Data Unit A05194 The unit is a packaged air conditioner for manufactured housing, residential, and light commercialapplications.

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE FAS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

GENERAL ELECTRIC FAN COIL UNITS

GENERAL ELECTRIC FAN COIL UNITS GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Geoclima has its engineering & production operations located at Monfalcone, Italy and has a design center in Austria.

Geoclima has its engineering & production operations located at Monfalcone, Italy and has a design center in Austria. Company Business Zamil Air Conditioners was founded in 974 as one of the first air conditioning companies to be established in Saudi Arabia and today is a leading international manufacturer of air conditioning

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

WE MAKE INDOOR AIR BETTER

WE MAKE INDOOR AIR BETTER WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable

More information

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number * COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual,

More information

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all

More information

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information