ROOF TOP PACKAGE UNITS
|
|
- Nigel Daniels
- 5 years ago
- Views:
Transcription
1 ROOF TOP PACKAGE UNITS HIEER : 3-25 Tons PRODUCT DATA BOOK
2
3 Introduction Roof Top Package units have been developed & produced to provide not only the ultimate indoor comfort, but also to guarantee long & trouble free operations. Herein lies the reason for the Choice of only the highest quality components and design strategies to meet the most important objectives such as, 3 TO 25 TONS CAPACITY ROOF TOP PACKAGE UNITS 3
4 SALIENT FEATURES 4
5 OPTIONAL / STANDARD FEATURES MODEL WISE LIST PART MODEL Package Unit Optional Accessories: 5.0 Kw Electric Heater - 1 Stage (Available for 3RTH060 to 3RTH060) Option Option Option Option Option Option Option Option Option Option Option 10.0 Kw Electric Heater - 1 Stage (Available for 3RTH060 to 3RTH060) Option Option Option Option Option Option Option Option Option 15.0 Kw Electric Heater - 1 Stage (Available for 3RTH072 to 3RTH090) Option Option Option Option Option Option Option Option 20.0 Kw Electric Heater - 2 Stage (Available for 3RTH120 to 3RTH150) Option Option Option Option Option Option 25.0 Kw Electric Heater - 2 Stage (Available for 3RTH1 to 3RTH216) Option Option Option Option 30.0 Kw Electric Heater - 2 Stage (Available for 3RTH240 to 3RTH300) Option Option Over Load External Protection Blower Motor Option Option Option Option Option Option Option Option Option STD STD Anti Ice Thermostat Option Option Option Option Option Option Option Option Option Option Option IP55,Class F Blower Motor Option Option Option Option Option Option Option STD STD STD STD Copper Tube Copper Fins Evaporater Coil Option Option Option Option Option Option Option Option Option Option Option Hydrophilic Fins Evaporator Coil Option Option Option Option Option Option Option Option Option Option Option Stainless Steel Drain Pan Option Option Option Option Option Option Option Option Option Option Option Filter Differential Pressure Switch Option Option Option Option Option Option Option Option Option Option Option Over Load External Protecion Compressor Option Option Option Option Option Option Option Option Option STD STD Over Load External Protecion Condenser Fan Option Option Option Option Option Option Option Option Option Option Option Compressor Alternating Switch Option Option Option Option Option Option Option Option Option Option Option Hour Run Meter Option Option Option Option Option Option Option Option Option Option Option Fan Cycling Switch (On / Off) Option Option Option Option Option Option Option Option Option Option Option Low Ambiant Kit Option Option Option Option Option Option Option Option Option Option Option Controller, Hi/Lo Voltage, Phase Loss/Reversal (Adjustable) STD STD STD STD STD STD STD STD STD STD STD Circuit Breaker Compressor(MCB) Option Option Option Option Option Option Option Option Option Option Option Circuit Breaker Cond. Fan Motor(MCB) Option Option Option Option Option Option Option Option Option Option Option Circuit Breaker Blower Motor(MCB) Option Option Option Option Option Option Option Option Option Option Option IP55, Class F Cond.Motor Option Option Option Option STD Option Option Option STD STD STD Heresite Coating For Condenser Coil Option Option Option Option Option Option Option Option Option Option Option Copper Tube Copper Fins Condenser Coil Option Option Option Option Option Option Option Option Option Option Option Pump Down System Option Option Option Option Option Option Option Option Option Option Option Dual Adjustable Pressure Switch Option Option Option Option Option Option Option Option Option Option Option Hot Gas Bypass (With Solenoid) Option Option Option Option Option Option Option Option Option Option Option Pressure Guage (Suction / Discharge) Option Option Option Option Option Option Option Option Option Option Option Roto Lock Compressor Option Option Option Option Option Option Option Option Option Option Option 5
6 MODEL DECODING 1 2/3 4 5 / 6 / / CAC PRODUCT LINE 3 RT = ROOF TOP CAC ID = INDOOR OD= OUTDOOR ON =OUTDOOR PRODUCT TYPE H = HIEER CAPACITY EXAMPLE 012 = BTU/HR 072 = BTU/HR 300 = BTU/HR ELECTRIC CODE F = V/1PH/50HZ S = V/1PH/60HZ P = V/1PH/60HZ E = 3-400V/3PH/60HZ APPLICATION C = COOL ONLY E = COOL + ELE. HTR H = COOL + HP A = HP +AUX. ELE. HTR CIRCUIT 1 = SINGLE 2 = DUAL 3 = TRIPLE 4 = QUADRUPLE COMPRESSOR R = RECIP (R-22) S = SCROLL(R-22) T = ROTARY (R-22) E = RECIP (R407C) FACTORY OPTIONS AA = STANDARD BA TO ZZ = NON STANDARD CONTROL VOLT X = 240 VOLTS Y = 24 VOLTS M = MICRO PROCESSOR SPL / FACTORY/ OPTIONS AW = AWAL STANDARD BA TO ZZ = NON STANDARD G = 3-415V/3PH/50HZ L = SCROLL(R407C) K = 460 V/ 3PH/60HZ Y = ROTARY(R-407C) T = V/ 3PH/60HZ A = RECIP(R410A) B = SCROLL(R410A) C = ROTARY(R410A) W = NO COMP(R-22) X = NO COMP(R-407C) Z = NO COMP(R-410A) D = DIGIT. SCR(R410A) F = DIGIT. SCR.(R-22) Z = DIGIT. SCR(R-407C) 6
7 G.A. DRAWING: 3TR - 5TR UNITS 7
8 G.A. DRAWING: 6TR - 10TR UNITS 8
9 G.A. DRAWING: 12.5TR - 25TR UNITS 9
10 ENGINEERING SPECIFICATIONS : 3TR - 25TR UNITS Description Air Flow (Evaporator) External static pressure Refrigerant Type Type Unit of measureme nt UNIT MODEL 3RTH036GC1 3RTH048GC 3RTH060GC1 3RTH072GC1 3RTH090GC1 3RTH120GC2 3RTH150GC2 3RTH1GC2 3RTH216GC2 3RTH240GC2 3RTH300GC2 Btu /Hr 34,200 47,926 60,000 69,872 96, , , , , , ,543 Watts 3,339 4,679 5,655 6,492 9,197 11,415 13,407 17,038 21,3 23,628 27, Btu /Hr 28,084 37,400 55,6 64,608 89, ,2 130,2 155, , , ,464 Watts 4,0 5,400 6,8 7,968 11,008 13,848 16,061 19,637 24,593 27,301 33,928 Kwatts/tr CFM 1,224 1,6 1,962 2,286 2,857 3,810 4,2 5,715 6,858 7,620 9,525 Inch H20 g 0.2" 0.2" 0.35" 0.4" 0.4" 0.4" 0.4" 0.4" 0.4" 0.4" 0.6" R407C Centrifugal Blower Drive Direct Drive Direct Drive Dia x width 12" x 6" 11" x 9" 12" x 12" 12" x 12" 15" x 15" 15" x 15" 15" x 15" 15" x 15" 15" x 15" twin 15" x 15" twin 15" x 15" twin Belt Drive Qty Evaporator Blower Motor Air filter Type Supply V/Ph/Hz V/1Ph/50 Hz 3-415V/3Ph/50 Hz HP 1/3 3/4 1 1/3 1 1/3 1 1/3 2 2/3 2 2/ /2 Aluminum Filter Face Area Sq.ft Evaporator CoTube Dia / no of row/ FPI Material Tubes - Fins Type Expansion val Qty 3/8" / 3 / 14 3/8" / 3 / 16 3/8" / 4 / 16 3/8" / 3 / 16 3/8" / 4 / 16 3/8" / 3 / 16 3/8" / 4 / 16 3/8" / 4 / 16 1/2" / 3 / 12 1/2" / 3 / 12 1/2" / 4 / 14 CU-AL TEX VALVE Supply air Op W X H mm 350 x x x x x x x x x x x 374 Return air Op W X H mm 345 x x x x x x x x 8 19 x x x 1089 Supply V/Ph/Hz 3-415V/3Ph/50 Hz Type Reciprocating SCROLL Quantity Protection Compressor Cranckcase heater Qty x Watts - 1x70 1x70 1x70 1x70 2x70 2x70 2x90 2x90 2x90 2x90 Internal Condenser Condenser Fan Min/Max Volts 342/ / / / / / / / / / /456 Locked Rotor Amperes Amps Running Rotor Amperes Type Propeller / Direct driven Qty Dia of Fan Inch 20" 24" 26" 26" 26" 25" 26" 26" 30" 30" 30" Type of coil Corrugated al fin with Inner grooved copper coil Condenser Coil Face Area Sq.ft x x x x x x4 Tube Dia / no of row/ FPI 3/8"/ 2 / 15 3/8" / 3 / 14 3/8" / 3 / 14 3/8" / 4 / 14 3/8" / 4 / 15 3/8" / 3 / 15 3/8" / 3 / 14 3/8" / 3 / 16 3/8" / 2 / 14 3/8" / 3 / 14 3/8" / 4 / 14 Supply V/Ph/Hz /1/ /3/ /1/ /3/50 Condensar Fan Motor HP 1/3 1/3 1/2 1/2 1 1/2 1/2 1/2 1/2 1 1/2 1 1/2 1 1/2 Qty nos Length Dimensions Width mm Height Aproximate Unit Weight LB / KG 506 / / / / / / / / / / / 1701 Note: As a result of continous reaserch& development, the above specifications are subject to change without notice, need to contact our sales team time to time *Cooling & Consumption / Ton are rated as per ESMA T3 condition 10
11 ELECTRICAL DATA FOR 3TR - 25TR - 50 Hz UNITS 3-415V-3PH-50HZ ("G" VOLTAGE) POWER SUPPLY MODEL V-Ph-Hz OPERATING VOLTAGE COMPRESSOR CONDENSER MOTOR BLOWER MOTOR HEATER (OPTION) MCA (COOL) MCA (HEAT) MOCP (COOL) MOCP (HEAT) MIN MAX TYPE RLA LRA QTY HP FLA QTY HP FLA KW AMPS AMPS AMPS AMPS AMPS 3RTH036G REC / / RTH048G SCR / / RTH060G SCR / / RTH072G SCR / / RTH090G SCR / / RTH120G SCR / / RTH150G SCR / / RTH1G SCR / RTH216G SCR / RTH240G SCR / RTH300G SCR / / NOTE: REC - Reciprocating compressor, SCR- Scroll compressor, RLA-Running Load Amps, LRA-locked Rotor Amps, QTY-Quantity FLA-Full Load Amps, MCA-Minimum Circuit Amps, MOCP-Maximum Over Currect Protection, MOCP-Maximum over current protection 11
12 COOLING PERFORMANCE DATA FOR 3TR Model Evaporator CFM Dry Bulb Temp. F Wet Bulb Temp. F RTH
13 COOLING PERFORMANCE DATA FOR TR Evaporato Dry Bulb Wet Bulb Model r CFM Temp. F Temp. F RTH
14 COOLING PERFORMANCE DATA FOR 5TR 85F 95F 105F 115F 120F 125F Model Evaporat Dry Bulb Wet Bulb or CFM Temp. F Temp. F Input Watt Input Watt Input Watt Input Watt Input Watt Input Watt RTH
15 COOLING PERFORMANCE DATA FOR 6TR 85F 95F 105F 115F 120F 125F Model Evaporat Dry Bulb Wet Bulb or CFM Temp. F Temp. F RTH
16 COOLING PERFORMANCE DATA FOR 7.5TR 85F 95F 105F 115F 120F 125F Model Evaporato Dry Bulb r CFM Temp. F Wet Bulb Temp. F RTH
17 COOLING PERFORMANCE DATA FOR 10TR 85F 95F 105F 115F 120F 125F Model Evaporato Dry Bulb r CFM Temp. F Wet Bulb Temp. F RTH
18 COOLING PERFORMANCE DATA FOR 12.5TR 85F 95F 105F 115F 120F 125F Model Evaporator CFM Dry Bulb Temp. F Wet Bulb Temp. F Input Watt Input Watt Input Watt Input Watt Input Watt Input Watt RTH
19 COOLING PERFORMANCE DATA FOR 15TR Model Evaporato r CFM Dry Bulb Temp. F Wet Bulb Temp. F 85F 95F 105F 115F 120F 125F RTH
20 COOLING PERFORMANCE DATA FOR 18TR Model Evaporato r CFM Dry Bulb Temp. F Wet Bulb Temp. F 85F 95F 105F 115F 120F 125F RTH
21 COOLING PERFORMANCE DATA FOR 20TR 85F 95F 105F 115F 120F 125F Model Evaporato Dry Bulb r CFM Temp. F Wet Bulb Temp. F RTH
22 COOLING PERFORMANCE DATA FOR 25TR 85F 95F 105F 115F 120F 125F Model Evaporator CFM Dry Bulb Temp. F Wet Bulb Temp. F RTH
23 FAN PERFORMANCE DATA FOR 3TR-7.5 TR MODEL 3RTH036GC1 3RTH048GC1 MODEL 3RTH036GC1-3RTH048GC1-50HZ UNITS AIR FLOW (CFM) SPEED MODE EXTERNAL STATIC PRESSURE (IN WG) LOW SPEED HIGH SPEED LOW SPEED HIGH SPEED MODEL 3RTH060GC1 External static pressure (inch of WG) Air flow (cfm) RPM BHP MODEL 3RTH072GC1 External static pressure (inch of WG) Air flow (cfm) RPM BHP External static pressure (inch of WG) Air flow (cfm) RPM BHP NOTE ABOVE DATA INCLUDES THE LOSSES THROUGH WET COIL AND CASING AREAS SHADED INDICATE OPERATING RANGE INSIDE THE STANDARD MOTOR. IF BHP IS EXCEEDING THAN THE STANDARD MOTOR THEN HIGHER CAPACITY MOTOR CAN BE PROVIDED AS AN OPTION. BOLD FONT IN RPM COLUMN INDICATE BLOWER SPEED WITH FACTORY SETTING. 23
24 FAN PERFORMANCE DATA FOR 10TR-15 TR UNITS MODEL 3RTH120GC (cfm) RPM BHP MODEL 3RTH150GC2 External static pressure (inch of WG) Air flow (cfm) RPM BHP MODEL 3RTH1GC (cfm) RPM BHP NOTE ABOVE DATA INCLUDES THE LOSSES THROUGH WET COIL AND CASING AREAS SHADED INDICATE OPERATING RANGE INSIDE THE STANDARD MOTOR. IF BHP IS EXCEEDING THAN THE STANDARD MOTOR THEN HIGHER CAPACITY MOTOR CAN BE PROVIDED AS AN OPTION. BOLD FONT IN RPM COLUMN INDICATE BLOWER SPEED WITH FACTORY SETTING. 24
25 FAN PERFORMANCE DATA FOR 18TR-25 TR UNITS MODEL 3RTH216GC2 External static pressure (inch of WG) Air flow (cfm) RPM BHP MODEL 3RTH240GC2 External static pressure (inch of WG) Air flow (cfm) RPM BHP MODEL 3RTH300GC2 External static pressure (inch of WG) Air flow (cfm) RPM BHP , NOTE ABOVE DATA INCLUDES THE LOSSES THROUGH WET COIL AND CASING AREAS SHADED INDICATE OPERATING RANGE INSIDE THE STANDARD MOTOR. IF BHP IS EXCEEDING THAN THE STANDARD MOTOR THEN HIGHER CAPACITY MOTOR CAN BE PROVIDED AS AN OPTION. BOLD FONT IN RPM COLUMN INDICATE BLOWER SPEED WITH FACTORY SETTING. 25
26 WIRING DIAGRAM FOR 3TR & 4TR UNITS POWER SUPPLY WIRING DIAGRAM FOR PACKAGE UNITS OPT2 L1 BLK/10 AFS BC BLK BLU BM BMC - AIR FLOW SWITCH - BLOWER CAPACITOR - BLACK - BLUE - BLOWER MOTOR - BLOWER MOTOR CONTACTOR RED/64 BRN CC - BROWN - COMP CONTACTOR R S T YEL/54 CCH CB - CRANK CASE HEATER - CIRCUIT BREAKER COM NC NO RED/4 YEL/5 BLU/6 BRN/12 YEL/13 BRN/34 COMP F FC FM - COMPRESSOR - FUSE - FAN CAPACITOR - FAN MOTOR FMC - FAN MOTOR CONTACTOR FMR HC - FAN MOTOR RELAY - HEATER CONTACTOR HPS - HIGH PRESSURE SWITCH N L1 OPT2 HTR HVTB L - HEATER - HIGH VOLTAGE TERMINAL BLOCK - LINE LPS - LOW PRESSURE SWITCH LVTB - LOW VOLTAGE TERMINAL BLOCK BLK/10 N NC - NEUTRAL - NORMALLY CLOSED NO - NORMALLY OPEN OHT - OVER HEAT THERMOSTAT R COM S NC T NO RED/4 YEL/5 BLU/6 BRN/12 YEL/13 BRN/34 OPT PLP PRI RED SEC SW TDS TRANS T.STAT - OPTIONAL - PHASE LOSS PROTECTION - PRIMARY - RED - SECONDARY - SWITCH ON / OFF - TIME DELAY SWITCH - TRANSFORMER - THERMOSTAT UVM - UNDER VOLTAGE MONITOR YEL - YELLOW - FIELD WIRING - TERMINAL / SPLICE - OPTIONAL MARKING - EARTHING TRANSFORMER 1) ANY WIRE REPLACEMENT SHOULD BE OF 90 C TYPE OR EQUALENT AND COPPER CONDUCTOR ONLY. 2) POWER MUST BE SUPPLIED TO CRANK CASE HEATER FOR A MINIMUM OF 12 HOURS PRIOR TO START UP. IF THE POWER SUPPLY HAS BEEN INTERRUPTED FOR LONGER PERIOD THEN AGAIN CRANK CASE HEATER MUST BE ENERGIZED FOR MINIMUM OF 12 HOURS BEFORE STARTING OF COMPRESSOR. 3) FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY THE USER WITH RELEVENT RATING. R 4) PLEASE ALLOW 2 TO 3 MINUTES BEFORE STARTING OF COMPRESSOR. LVTB 5) COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD PROTECTION. SW1 LPS1 HPS1 TDS1 6) POWER CIRCUIT FOR V/3PH/60HZ 7) POWER CIRCUIT FOR V/3PH /50HZ, V/3PH/60Hz & 460 V/3PH/60HZ WITH NEUTRAL 8) REFER INSTRUCTIONS WITH THE COMPO NENTS FOR STAR / DELTA CONNECTIONS OPT2 9) IF THE POWER SUPPLY IS 230V, CONNECT TO L1 IF THE POWER SUPPLY IS 3V, CONNECT TO N OPT. 1 - NIL OPT. 2 - SINGLE STAGE HEATING 26
27 WIRING DIAGRAM FOR 5TR & 6TR UNITS POWER SUPPLY WIRING DIAGRAM FOR PACKAGE UNITS OPT2 L1 BLK/10 AFS BLK BLU BM BMC - AIR FLOW SWITCH - BLACK - BLUE - BLOWER MOTOR - BLOWER MOTOR CONTACTOR BRN - BROWN R COM S NC T NO RED/4 YEL/5 BLU/6 BRN/12 RED/64 YEL/54 YEL/13 CC CCH CB COMP F FC FM FMC - COMP CONTACTOR - CRANK CASE HEATER - CIRCUIT BREAKER - COMPRESSOR - FUSE - FAN CAPACITOR - FAN MOTOR - FAN MOTOR CONTACTOR FMR HC - FAN MOTOR RELAY - HEATER CONTACTOR HPS - HIGH PRESSURE SWITCH HTR - HEATER N L1 OPT2 HVTB L LPS - HIGH VOLTAGE TERMINAL BLOCK - LINE - LOW PRESSURE SWITCH LVTB - LOW VOLTAGE TERMINAL BLOCK N - NEUTRAL BLK/10 NC NO - NORMALLY CLOSED - NORMALLY OPEN OHT - OVER HEAT THERMOSTAT R COM S NC T NO OPT PLP PRI RED SEC SW TDS TRANS - OPTIONAL - PHASE LOSS PROTECTION - PRIMARY - RED - SECONDARY - SWITCH ON / OFF - TIME DELAY SWITCH - TRANSFORMER RED/4 YEL/5 BLU/6 BRN/12 YEL/13 T.STAT UVM - THERMOSTAT - UNDER VOLTAGE MONITOR YEL - YELLOW - FIELD WIRING - TERMINAL / SPLICE - OPTIONAL MARKING - EARTHING TRANSFORMER 1) ANY WIRE REPLACEMENT SHOULD BE OF 90 C TYPE OR EQUALENT AND COPPER CONDUCTOR ONLY. 2) POWER MUST BE SUPPLIED TO CRANK CASE HEATER FOR A MINIMUM OF 12 HOURS PRIOR TO START UP. IF THE POWER SUPPLY HAS BEEN INTERRUPTED FOR LONGER PERIOD THEN AGAIN CRANK CASE HEATER MUST BE ENERGIZED FOR MINIMUM OF 12 HOURS BEFORE STARTING OF COMPRESSOR. 3) FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY THE USER WITH RELEVENT RATING. R 4) PLEASE ALLOW 2 TO 3 MINUTES BEFORE STARTING OF COMPRESSOR. LVTB 5) COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD PROTECTION. SW1 LPS1 HPS1 TDS1 6) POWER CIRCUIT FOR V/3PH/60HZ 7) POWER CIRCUIT FOR V/3PH /50HZ, V/3PH/60Hz & 460 V/3PH/60HZ WITH NEUTRAL 8) REFER INSTRUCTIONS WITH THE COMPO NENTS FOR STAR / DELTA CONNECTIONS OPT2 9) IF THE POWER SUPPLY IS 230V, CONNECT TO L1 IF THE POWER SUPPLY IS 3V, CONNECT TO N OPT. 1 - NIL OPT. 2 - SINGLE STAGE HEATING 27
28 WIRING DIAGRAM FOR 7.5TR UNITS POWER SUPPLY THIS WIRING DIAGRAM SUITS VOLTS / 3 PH / 60 HZ V / 3 PH / 50 HZ WITH NEUTRAL V / 3 PH / 60 HZ WITH NEUTRAL 460 VOLTS / 3 PH / 60 HZ WITH NEUTRAL PL. REFER UNIT NAME PLATE FOR YOUR UNIT'S POWER SUPPLY R COM R COM S NC S NC T NO T NO BLK/10 BLK/10 RED/4 YEL/5 BLU/6 RED/4 YEL/5 BLU/6 WIRING DIAGRAM FOR PACKAGE UNITS WARNING THIS UNIT IS BUILT AND WIRED ACCORDING TO COMPANY STANDARDS AND / OR JOB ORDER'S SPECIFICATIONS. ANY UNAUTHORISED CHANGE OR MODIFICATION OR SETTING OF ROOM THERMOSTAT TEMPERATURE BELOW 60 F WILL MAKE WARRANTY NULL & VOID. POWER SUPPLY POWER SUPPLY (SEE NOTE 6) (SEE NOTE 7) OPT 2 OPT 2 LEGEND AFS AUX BLK BLU BM BMC BRN CC CCH CB COMP F FM FMC HC HM HPS HTR HVTB L LPS LVTB N NC NO OHT OLR OPT PLP PRI RED SEC SSPS SW TDS TRANS T.STAT UVM YEL - AIR FLOW SWITCH - AUXILIARY - BLACK - BLUE - BLOWER MOTOR - BLOWER MOTOR CONTACTOR - BROWN - COMP CONTACTOR - CRANK CASE HEATER - CIRCUIT BREAKER - COMPRESSOR - FUSE - FAN MOTOR - FAN MOTOR CONTACTOR - HEATER CONTACTOR - HOUR METER - HIGH PRESSURE SWITCH - HEATER - HIGH VOLTAGE TERMINAL BLOCK - LINE - LOW PRESSURE SWITCH - LOW VOLTAGE TERMINAL BLOCK - NEUTRAL - NORMALLY CLOSED - NORMALLY OPEN - OVER HEAT THERMOSTAT - OVER LOAD RELAY - OPTIONAL - PHASE LOSS PROTECTION - PRIMARY - RED - SECONDARY - SOLID STATE PROTECTION SYS. - SWITCH ON/ OFF - TIME DELAY SWITCH - TRANSFORMER - THERMOSTAT - UNDER VOLTAGE MONITOR - YELLOW - FIELD WIRING - TERMINAL / SPLICE - OPTIONAL MARKING - EARTHING NOTES 1) ANY WIRE REPLACEMENT SHOULD BE OF 90 C TYPE OR EQUALENT AND OF 90 C TYPE OR EQUALENT AND COPPER CONDUCTOR ONLY COPPER CONDUCTOR ONLY. 2) POWER MUST BE SUPPLIED TO CRANK CASE HEATER FOR A MINIMUM OF 12 HOURS PRIOR TO START UP. IF THE POWER SUPPLY HAS BEEN INTERRUPTED POWER SUPPLY HAS BEEN INTERRUPTED FOR LONGER PERIOD THEN AGAIN CRANK FOR LONGER PERIOD THEN AGAIN CRANK CASE HEATER MUST BE ENERGIZED FOR MINIMUM OF 12 HOURS BEFORE STARTING OF COMPRESSOR TRANSFORMER 3) FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY THE USER WITH RELEVENT RATING. 4) PLEASE ALLOW 2 TO 3 MINUTES BEFORE STARTING OF COMPRESSOR BEFORE STARTING OF COMPRESSOR. 5) COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD PROTECTION INTERNAL OVERLOAD PROTECTION. 6) POWER CIRCUIT FOR /3PH/60HZ R LVTB 7) POWER CIRCUIT FOR V/3PH /50HZ, V/3PH/60Hz 460 V/3PH/60HZ WITH NEUTRAL 8) REFER INSTRUCTIONS WITH THE COMPONENTS FOR STAR / DELTA CONNECTIONS SW1 LPS1 HPS1 TDS1 9) IF THE POWER SUPPLY IS 230V, CONNECT TO L1 IF THE POWER SUPPLY IS 3V, CONNECT TO N OPT2 OPTIONS OPT. 1 - NIL OPT. 2 - SINGLE STAGE HEATING WIR.DIA.RTP.1COM.3PH FAN-SPL C BCO11C
29 WIRING DIAGRAM FOR 10TR, 12.5TR & 15TR UNITS POWER SUPPLY THIS WIRING DIAGRAM SUITS VOLTS / 3 PH / 60 HZ WIRING DIAGRAM FOR PACKAGE UNITS V / 3 PH / 50 HZ WITH NEUTRAL V / 3 PH / 60 HZ WITH NEUTRAL WARNING 460 VOLTS / 3 PH / 60 HZ WITH NEUTRAL PL. REFER UNIT NAME THIS UNIT IS BUILT AND WIRED ACCORDING TO COMPANY STANDARDS AND / OR JOB ORDER'S SPECIFICATIONS. ANY UNAUTHORISED CHANGE OR PLATE FOR YOUR UNIT'S POWER SUPPLY MODIFICATION OR SETTING OF ROOM THERMOSTAT TEMPERATURE BELOW 60 F WILL MAKE WARRANTY NULL & VOID. POWER SUPPLY (SEE NOTE 6) OPT2 OPT3 L1 LEGEND BLK/10 BLK/30 AFS BLK BLU BM BMC - AIR FLOW SWITCH - BLACK - BLUE - BLOWER MOTOR - BLOWER MOTOR CONTACTOR BRN - BROWN R COM S NC T NO RED/4 YEL/5 BLU/6 BRN/12 RED/64 YEL/54 YEL/13 RED/66 YEL/55 YEL/16 BRN/15 CC CCH CB COMP F FC FM FMC - COMP CONTACTOR - CRANK CASE HEATER - CIRCUIT BREAKER - COMPRESSOR - FUSE - FAN CAPACITOR - FAN MOTOR - FAN MOTOR CONTACTOR FMR HC - FAN MOTOR RELAY - HEATER CONTACTOR HPS - HIGH PRESSURE SWITCH N L1 POWER SUPPLY (SEE NOTE 7) OPT2 OPT3 HTR HVTB L LPS - HEATER - HIGH VOLTAGE TERMINAL BLOCK - LINE - LOW PRESSURE SWITCH LVTB - LOW VOLTAGE TERMINAL BLOCK N - NEUTRAL BLK/10 BLK/30 NC NO - NORMALLY CLOSED - NORMALLY OPEN OHT - OVER HEAT THERMOSTAT R COM S NC T NO YEL/55 OPT PLP PRI RED SEC SW TDS TRANS - OPTIONAL - PHASE LOSS PROTECTION - PRIMARY - RED - SECONDARY - SWITCH ON / OFF - TIME DELAY SWITCH - TRANSFORMER RED/4 YEL/5 BLU/6 BRN/12 YEL/13 YEL/16 BRN/15 T.STAT UVM - THERMOSTAT - UNDER VOLTAGE MONITOR YEL - YELLOW - FIELD WIRING - TERMINAL / SPLICE - OPTIONAL MARKING - EARTHING TRANSFORMER NOTES 1) ANY WIRE REPLACEMENT SHOULD BE OF 90 C TYPE OR EQUALENT AND OF 90 C TYPE OR EQUALENT AND COPPER CONDUCTOR ONLY. COPPER CONDUCTOR ONLY. 2) POWER MUST BE SUPPLIED TO CRANK CASE HEATER FOR A MINIMUM OF 12 HOURS PRIOR TO START UP. IF THE POWER SUPPLY HAS BEEN INTERRUPTED FOR LONGER PERIOD THEN AGAIN CRANK CASE HEATER MUST BE ENERGIZED FOR MINIMUM OF 12 HOURS BEFORE STARTING OF COMPRESSOR. R LVTB 3) FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY THE USER WITH RELEVENT RATING. 4) PLEASE ALLOW 2 TO 3 MINUTES BEFORE STARTING OF COMPRESSOR. BEFORE STARTING OF COMPRESSOR. SW1 LPS1 HPS1 TDS1 5) COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD PROTECTION INTERNAL OVERLOAD PROTECTION. 6) POWER CIRCUIT FOR V/3PH/60HZ 7) POWER CIRCUIT FOR V/3PH /50HZ, V/3PH/60Hz 460 V/3PH/60HZ WITH NEUTRAL SW2 LPS2 HPS2 TDS2 8) REFER INSTRUCTIONS WITH THE COMPO NENTS FOR STAR / DELTA CONNECTIONS NENTS FOR STAR / DELTA CONNECTIONS OPT2 9) IF THE POWER SUPPLY IS 230V, CONNECT TO L1 IF THE POWER SUPPLY IS 3V, CONNECT TO N OPT3 OPTIONS OPT. 1 - NIL OPT. 2 - SINGLE STAGE HEATING OPT. 3 - TWO STAGE HEATING C BCO11C
30 WIRING DIAGRAM FOR 10TR, 12.5TR & 15TR UNITS POWER SUPPLY WIRING DIAGRAM FOR PACKAGE UNITS OPT 2 OPT 3 AFS AUX - AIR FLOW SWITCH - AUXILIARY BLK - BLACK BLK/10 BLK/30 BLU BM - BLUE - BLOWER MOTOR BMC - BLOWER MOTOR CONTACTOR BRN - BROWN CC - COMP CONTACTOR CCH - CRANK CASE HEATER CB - CIRCUIT BREAKER R COM S NC T NO NOTE 11 COMP F - COMPRESSOR - FUSE FM - FAN MOTOR RED/4 YEL/5 BLU/6 FMC HC HM - FAN MOTOR CONTACTOR - HEATER CONTACTOR - HOUR METER HPS HTR - HIGH PRESSURE SWITCH - HEATER OPT 2 OPT 3 HVTB L LPS LVTB N - HIGH VOLTAGE TERMINAL BLOCK - LINE - LOW PRESSURE SWITCH - LOW VOLTAGE TERMINAL BLOCK - NEUTRAL BLK/10 BLK/30 NC NO - NORMALLY CLOSED - NORMALLY OPEN OHT - OVER HEAT THERMOSTAT OLR - OVER LOAD RELAY OPT - OPTIONAL PLP - PHASE LOSS PROTECTION PRI - PRIMARY R COM S NC T NO NOTE 11 RED SEC SSPS - RED - SECONDARY - SOLID STATE PROTECTION SYS. SW - SWITCH ON/ OFF RED/4 YEL/5 BLU/6 TDS TRANS - TIME DELAY SWITCH - TRANSFORMER T.STAT UVM YEL - THERMOSTAT - UNDER VOLTAGE MONITOR - YELLOW - FIELD WIRING - TERMINAL / SPLICE - OPTIONAL MARKING - EARTHING 1) ANY WIRE REPLACEMENT SHOULD BE OF 90 C TYPE OR EQUALENT AND OF 90 C TYPE OR EQUALENT AND COPPER CONDUCTOR ONLY. COPPER CONDUCTOR ONLY. 2) POWER MUST BE SUPPLIED TO CRANK CASE HEATER FOR A MINIMUM OF 12 HOURS PRIOR TO START UP.. IF THE POWER SUPPLY HAS BEEN INTERRUPTED POWER SUPPLY FOR LONGER PERIOD THEN AGAIN CRANK CASE HEATER MUST BE ENERGIZED FOR MINIMUM OF 12 HOURS BEFORE STARTING OF COMPRESSOR. 3) FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY THE USER WITH RELEVENT RATING. TRANSFORMER 4) PLEASE ALLOW 2 TO 3 MINUTES BEFORE STARTING OF COMPRESSOR. BEFORE STARTING OF COMPRESSOR. 5) COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD PROTECTION. INTERNAL OVERLOAD PROTECTION. 6) POWER CIRCUIT FOR /3PH/60HZ 7) POWER CIRCUIT FOR V/3PH /50HZ, V/3PH/60Hz & R LVTB 460 V/3PH/60HZ WITH NEUTRAL 8) REFER INSTRUCTIONS WITH THE COMPO NENTS FOR STAR / DELTA CONNECTIONS 9) IF THE POWER SUPPLY IS 230V, CONNECT TO L1 IF THE POWER SUPPLY IS 3V, CONNECT TO N SW1 LPS1 HPS1 TDS1 10) COMPRESSOR OVERLOAD RELAY WILL BE PROVIDED AS STANDARD FOR CAPACITY BTU 240K AND 300K ONLY 11) BLOWER MOTOR OVERLOAD RELAY WILL BE PROVIDED AS STANDARD FOR CAPACITY BTU 300K ONLY SW2 LPS2 HPS2 TDS2 OPT2 OPT. 1 - NIL OPT. 2 - SINGLE STAGE HEATING OPT. 3 - TWO STAGE HEATING OPT3 30
31
32
technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationManufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER
UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationEDN & ESN SERIES PRODUCT DATA BOOK. Capacity: 12,000 to 72,000 BTU/HR CONCEALED DUCTABLE SPLIT SYSTEMS
EDN & ESN SERIES CONCEALED DUCTABLE SPLIT SYSTEMS Capacity: 12,000 to 72,000 BTU/HR CONTENTS Page 1. INTRODUCTION 04 2. SALIENT FEATURES 05 3. G A DRAWINGS 07 4. UNIT SPECIFICATIONS 10 a. ENGINEERING SPECIFICATIONS
More informationOmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide
Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationPACKAGE AIR CONDITIONERS
PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform...
ACPSB-P Series Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R R407C Products that perform...by people who care NOMENCLATURE 6 AC P S B 435 P - Q P 6-60 Hz Blank - 50Hz Blank P - R - R407C
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More information10+ SEER - AIR CONDITIONER
10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser
More informationAir Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK
Air Cooled CHILLER CAPACITY: 25-206 TR 2 Company Business Awal Gulf Manufacturing, located at Bahrain is the one of the leading manufacturers of air conditioning and refrigeration products in Middle East
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationR2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz
3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator
More informationNew Stylus. Product Catalog. Split System, 1-5 Tons Convertible Type MCX Series 60 Hz MS-PRC015-EN. May 2009
Product Catalog New Stylus Split System, 1-5 Tons Convertible Type MCX Series 60 Hz Cooling Only Cooling with Electric Heat Indoor Units Outdoor Units Outdoor Units Outdoor Units MCX 512 G1 TTK512P1 2TTB0012A1
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationRCD Air Cooled Condensing Unit (50/60 Hz)
Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationR407C. ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz. Air Cooled Split Systems Cooling Capacity : 59 to 1327 MBH (17 to 389 kw)
ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz Air Cooled Split Systems Cooling Capacity : 59 to 27 MBH (7 to 89 kw) HEB-DP (Indoor) ACCS-P (Outdoor) VEB-DP (Indoor) R407C Products that perform...by people
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More informationACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)
-P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationCAC SERIES 3 to 5 Ton Split System Condensers
CAC SERIES 3 to 5 Ton Split System Condensers STANDARD FEATURES 10 11 SEER Three Phase High efficiency scroll compressors on all models Copper tube / aluminum fin coil Prepainted condenser fins Top air
More informationEngineering Data Book
40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationSingle Packaged Roof Top Air Conditioners PY Series. PY036 - PY360 3 TR thru 30 TR 10 kw thru 105 kw. The "Comfort" Series
Single Packaged Roof Top Air Conditioners PY Series PY036 - PY360 3 TR thru 30 TR 10 thru 105 The "Comfort" Series Company Business Zamil Air Conditioners was founded in 1974, and is the first major business
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationPAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01
PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling
More informationH4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Copeland
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationGPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h
ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on
More informationShandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit
Air Cooled Condensing Unit PERFORMANCE 10.00 SEER & 13.00 SEER Efficiency Range Cooling capacity from 1.5 to 5 tons T3 Tropical high efficiency Condensing units FEATURES Super quiet top air discharge Sheet
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationO5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES " - - -" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. 3rd
More informationN2AE - 50 Hz PRODUCT SPECIFICATIONS
ISO 9001:2000 REGISTERED N2AE - 50 Hz PRODUCT SPECIFICATIONS 50 Hz AIR CONDITIONING CONDENSING UNIT 230 Volt, 1-phase, 50 Hz in 1½, 2, 2½, 3, 4 tons 400 Volt, 3-phase, 50 Hz in 3, 3½, 4, 5 tons REFRIGERATION
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More information13 SEER CONDENSING UNITS
FORM NO. ATZ-218 REV. 1 Supersedes Form No. ATZ-205 Featuring Industry Standard R-410A Refrigerant 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationCOMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationSUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor
SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for
More informationCDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications
CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More information10+ SEER - AIR CONDITIONER
10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationProduct Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A
Product Data 22-1784-01 2/4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, 40-120 MBTU R-22/R-410A Mar. 03, 2006 2006 American Standard inc. All Rights Reserved
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationN2H3**C. Product Specifications EFFICIENT 13 SEER HEAT PUMP. Performance Series
N2H3**C Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP FOR COASTAL APPLICATIONS 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT Copeland Scroll compressors
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationGPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h
H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationDCH Commercial Contents Standard Features Cabinet Features
DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8
More informationDESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207
TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK
More informationDESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506
TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common
More information14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]
More informationPGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner
PGB SERIES 0 SEER SelfContained Gas/Electric Packaged Air Conditioner 2 and 5 Ton Cooling Capacity: 2,600 to 58,000 BTUH Heating Input Rates: 6,000 to 0,000 BTUH The PGB outdoor package unit is a selfcontained
More informationGPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h
Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT T4A3 SmartComfort TX 5300 Product Specifications EFFICIENT 13 AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationPHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing
More information