R407C. ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz. Air Cooled Split Systems Cooling Capacity : 59 to 1327 MBH (17 to 389 kw)

Size: px
Start display at page:

Download "R407C. ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz. Air Cooled Split Systems Cooling Capacity : 59 to 1327 MBH (17 to 389 kw)"

Transcription

1 ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz Air Cooled Split Systems Cooling Capacity : 59 to 27 MBH (7 to 89 kw) HEB-DP (Indoor) ACCS-P (Outdoor) VEB-DP (Indoor) R407C Products that perform...by people who care

2 NOMENCLATURE ACC S 45 Q P Air Cooled Condensing S - Scroll Compressor Code Blank P Blank Q - R22 - R407C - Standard - Special EB 45 D Q P VEB/ EB - Vertical Evaporator Blower HEB - Horizontal Evaporator Blower Code Generation Blank P Blank FB Q - R22 - R407C - Standard - Free Blow - Special AIR-COOLED CONDENSING UNITS GENERAL DESCRIPTION The ACCS series with new features is suitable for hotel, office, hospitals, schools, factory and supermarket applications. The low noise and compact series are completely leak tested, evacuated, dehydrated and charged with dry nitrogen to maintain system dryness prior to field piping connections. Scroll Compressor(s) Reliability No contact scroll design that minimizes friction, increases volumetric efficiency and reduces vibration, thus longer service life. Suction gas cooled motor. Low Power Consumption: High EER. No crankcase heater required. Tandem Compressor (ACCS 640P to 520P) For condensing units, every two compressors is connected in tandem, to reduce refrigerant circuits to or 4 and thus reduce the cost of labor and materials for field piping connection works. Class F Insulation Condenser Fan Motor (ACCS 08P to 520P) Extra safety margin and longer motor life even in extreme operating conditions. IP 55 construction ensure extra motor protection Low motor speed at 950 rpm ensures quiet condenser fan operation. Multiple Compressor (ACCS 220P to 520P) By cycling off compressor(s) operation to match building load, no energy is being wasted when room load requires lesser cooling capacity. No total shut down when servicing or repairing a faulty compressor

3 AIR-COOLED CONDENSING UNITS Efficient Condenser Coil Staggered row of /8 [9.5mm] OD inner groove tubes with 25 to 0% more surface area guarantee better heat transfer. Mechanically expanded into die-formed corrugated aluminum fins. Integral subcooling circuit to maximize efficiency. Leak and pressure tested to 450 psig [ bar]. Fully Leak Tested Refrigerant Circuit Leak and pressure tested at 450 psig [ bar]. Pressure ports are provided on the discharge, liquid and suction line. Evacuated, dehydrated and pressurized with dry nitrogen for storage and shipping purpose. Safety Control High-low pressure cutout to protect compressor from high discharge pressure and system leakage. Casing Constructed from heavy gauge galvanized steel. Panels are painted powder coated paint for excellent finish, weatherability and corrosion resistance. DUCTED EVAPORATOR BLOWER UNITS GENERAL DESCRIPTION The ducted evaporator-blower units; each consist of an evaporator coil, a centrifugal forward-curved blower fan complete with drive package and filters and enclosed in a single fibreglass insulated rigid steel cabinetry; are completely factory packaged to provide greater flexibility to the building owners, consultants, architects and installers. These flexibility includes; A wide range of model sizes covering cooling capacities from 59 to 27 MBH [7 to 89 kw]; and each model size also has a wide band of airflow rates (cfms) covering a wide band of static pressure to meet almost any system demands. Except for HEB 68DP to HEB 95DP which are specially designed for ducted, ceiling application, all other sizes allow flexibility for either horizontal air discharge or vertical air discharge ducted connections. All units can be provided with left or right hand piping connections. Except for HEB 68DP to HEB 95DP, which are direct driven, all units can also be left or right hand motor location to ease installation at site. This must be specified at the time of order entry to factory. Efficient Evaporator Coil Independent thermal expansion valve with external equalizer for better refrigerant control and wider load condition. Leak and pressure tested to 450 psig [ bar]. Evacuated, dehydrated and charged with dry nitrogen. Drive Package and Blowers (HEB 08DP to EB 520DP, VEB 08DP to VEB 250DP) Belt driven drive package offers flexibility on various air flow rate and various static pressure applications. Single large diameter double inlet double width blowers (AMCA certified) reduce the noise level and eliminates the need for common transition and eliminates air unbalance. Casing Constructed of cold rolled heavy gauge steel sheet and insulated with /2 [mm] thick x /2 lb/ft³ [24kg/m³] (up to EB 760DP) and [25mm] x /2 lb/ft³ [24kg/m³] (EB 800DP and above) linacoustic fiberglass. Aesthetically coated powder paint to provide excellent finish, weatherability and corrosion resistance. Removable panels on the left and right hand side of the unit to provide access to critical parts and components. Filters Side loading [25mm] thick filters - from both sidesthus eliminates unnecessary duct opening at site. - -

4 OPTIONAL ACCESSORIES FEATURES Factory wired starters - DOL for compressors and fan motors. - Auto-transformer for compressors. Suction stop valve(s), discharge stop valve(s) and liquid stop valve(s). Fan staging of multiple fans for head pressure control. Thermostat. Hydrophilic fins, copper fins for better corrosion resistance. Liquid line filter drier and sight glass. Hot gas by pass for low load and low ambient conditions. Hot water heating coils. Electric heaters. Optional R22 refrigerant. PHYSICAL SPECIFICATIONS AIR COOLED CONDENSING UNITS Power Supply Compressor MRA Each LRA Each NRA Each Face Area ft²[m²] Condenser Coil Rows/ FPI. Motor HP Each Condenser Fan Motor FLA Each Blade Dia. Inches[mm] APprox. Operating Weight ACCS 68P Hz - x45 x [.0] 2/4 2 / [457] 90 [77] ACCS 8P Hz x5.0 x0 x [.] 2/4 2 / [457] 96 [80] ACCS 95P Hz x5.6 x95 x [.] 2/6 2 / [457] 400 [8] ACCS 08P Hz x6.8 x x.7 5. [.4] 2/4 5/ [660] 450 [204] ACCS 25P Hz x9.6 x8 x [.4] 2/6 5/ [660] 480 [28] ACCS 45P Hz x22. x8 x [.4] /4 5/ [660] 500 [227] ACCS 60P Hz x25.6 x67 x [.6] 2/6 2 5/ [660] 780 [54] ACCS 90P Hz x0.0 x98 x [.6] /2 2 5/ [660] 840 [8] ACCS 220P Hz 2x6.8 2x 2x [.9] /2 2 5/ [660] 900 [408] ACCS 250P Hz 2x9.6 2x8 2x [.9] /6 2 5/ [660] 90 [422] ACCS 290P Hz 2x22. 2x8 2x [.9] 4/4 2 5/ [660] 990 [449] ACCS 20P Hz 2x25.6 2x67 2x [.0] /6 5/ [660] 450 [658] ACCS 80P Hz 2x0.0 2x98 2x [.5] /6 5/ [660] 600 [726] ACCS 45P Hz x2. x8 x [.5] 4/6 5/ [660] 800 [86] ACCS 480P Hz x25.6 x67 x [4.5] /4 4 5/ [660] 249 [] ACCS 50P Hz 2x25.6, x0.0 2x67 x98 2x9. x2.7 lbs[kg] 48.8 [4.5] /6 4 5/ [660] 2587 [7] ACCS 570P Hz x0.0 x98 x [4.5] 4/4 4 5/ [660] 2680 [26] ACCS 640P Hz 4x25.6 4x67 4x [6.] 4/6 /2.2.5 [800] [52] ACCS 700P Hz 2x25.6 2x0.0 2x67 2x98 2x9. 2x [6.] 4/6 /2.2.5 [800] 7 [50] ACCS 760P Hz 4x0.0 4x98 4x [6.7] 4/6 /2.2.5 [800] 456 [568] ACCS 800P Hz 5x25.6 5x67 5x [8.7] /6 4 /2.2.5 [800] 467 [29] ACCS 890P Hz 2x25.6 x0.0 2x67 x98 2x9. x [8.7] 4/4 4 /2.2.5 [800] 4700 [22] ACCS 960P Hz 6x25.6 6x67 6x [8.7] 4/6 4 /2.2.5 [800] 484 [297] ACCS 020P Hz 4x25.6 2x0.0 4x67 2x98 4x9. 2x [.4] /6 6 /2.2.5 [800] 5900 [2676] ACCS 40P Hz 6x0.0 6x98 6x [.4] 4/4 6 /2.2.5 [800] 6028 [274] ACCS 40P Hz 6x25.6, 2x0.0 6x67 2x98 6x9. 2x [2.0] 4/6 6 /2.2.5 [800] 6700 [09] ACCS 520P Hz 8x0.0 8x98 8x [2.0] 4/6 6 /2.2.5 [800] 689 [09] Notes:.) Condenser fan motors for ACCS 08P to 520P are for 400V--50Hz electrical supply. Condenser fan motors for ACCS 68P to 95P are for 20V- -50Hz electrical supply. 2.) Minimum - Maximum voltage is 60V-440V..) MRA - Maximum must trip amp. 4.) LRA - Locked rotor amp. 5.) NRA - Nominal running amp. 6.) FLA - Full load amp

5 PHYSICAL SPECIFICATIONS EVAPORATOR BLOWER UNITS Blower Section Blower Motor Fan Air Flow Dia. x Width Max HP FLA Each LRA Each HEB 68DP 0x HEB 8DP 0x HEB 95DP 2x VEB/ HEB 08DP VEB/ HEB 25DP VEB/ HEB 45DP VEB/ HEB 60DP VEB/ HEB 90DP VEB/ HEB 220DP VEB/EB 250DP 2x x x x x x x EB 290DP 8x EB 20DP 8x EB 80DP 8x EB 45DP 450x EB 480DP 500x EB 50DP 500x EB 570DP 500x EB 640DP 560x EB 700DP 560x EB 760DP 560x EB 800DP 60x EB 890DP 60x EB 960DP 60x EB 020DP 70x Min-Max cfm[m³/hr] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] EB 40DP 70x [ ] EB 40DP 800x [ ] EB 520DP 800x [ ] Note: Power supply for HEB 68DP to 95DP is hz. Rows Deep Evaporator Coil Face Area ft²[m²] Filters Size inches[mm] Approx. Operating Weight lbs[kg] Suction Connection Size inches [mm] Liquid Connection Size inches [mm] 4.5 [0.4] 2 6x20x [406x50x25] 260 [8] 7/8 [22] /8 [0] 4.5 [0.4] 2 6x20x [406x50x25] 275 [25] 7/8 [22] /2 [] 5.0 [0.5] 2 20x20x [50x50x25] 40 [54] /8 [29] /2 [] 7.2 [0.7] 7.2 [0.7] [0.7] 60 [6] /8 [29] /2 [] 80 [72] /8 [5] /2 [] 400 [8] /8 [5] 5/8 [6] 9. [0.9] [2] /8 [5] 5/8 [6] 9. [0.9] [227] /8 [5] 5/8 [6].0 [.2].0 [.2] 7.5 [.6] [.6] 22.5 [2.] 22.5 [2.] 2 2 6x25x [406x65x25] 6x25x [406x65x25] 500 [227] 2 /8 [29] 2 /2 [] 680 [08] 2 /8 [5] 2 /2 [] 900 [408] 2 /8 [5] 2 5/8 [6] 920 [47] 2 /8 [5] 2 5/8 [6] 00 [499] 2 /8 [5] 2 5/8 [6] 50 [522] /8 [5] 5/8 [6] 0.0 [2.8] [658] /8 [5] 5/8 [6] 0.0 [2.8] [689] /8 [5] 5/8 [6] 0.0 [2.8] [726] /8 [5] 5/8 [6] 5.0 [.] [.] [.] 48.8 [4.5] 48.8 [4.5] 54.2 [5.0] 54.2 [5.0] [5.0] EVAPORATOR FREE BLOWER UNITS Blower Section Blower Motor Hp Dia. X Width (Inches) Fan cfm[m³/hr] Rows Deep Evaporator Coil Nom Face Area ft²[m²] x20x [406x50x25] 6x25x [406x65x25] 6x25x [406x65x25] 6x25x [406x65x25] 6x25x [406x65x25] 6x25x [406x65x25] 820 [826] 2 5/8 [4] 2 7/8 [22] 860 [844] 2 5/8 [4] 2 7/8 [22] 900 [862] 2 5/8 [4] 2 7/8 [22] 200 [95] 280 [989] 2 2 5/8 [4] /8 [5] 5/8 [4] /8 [5] 2 2 7/8 [22] 5/8 [6] 7/8 [22] 5/8 [6] 2250 [02] 5/8 [4] 7/8 [22] 240 [06] 5/8 [4] 7/8 [22] 2400 [089] 5/8 [4] 7/8 [22] 78. [7.] [588] 4 5/8 [4] 4 7/8 [22] [7.] [70] 4 5/8 [4] 4 7/8 [22] Filters Size inches[mm] Suction Connection Size inches[mm] Liquid Connection Size inches [mm] VEB 68DP-FB 0-0 / [98] 5.4 [0.5] /8 x 8 /8 x /2 [50x460x] 7/8 [22] /8 [0] VEB 8DP-FB / 2400 [4078] 7.0 [0.7] /8 x 8 /8 x /2 [50x460x] 7/8 [22] /2 [] VEB 95DP-FB / 2600 [448] [0.7] /8 x 8 /8 x /2 [50x460x] /8 [29] /2 [] VEB 08DP-FB /2 200 [547] [0.7] /8 x 8 /8 x /2 [50x460x] /8 [29] /2 [] VEB 25DP-FB /2 500 [5947] 9.9 [0.9] 2 27 /4 x 8 /8 x /2 [705x460x] /8 [5] /2 [] VEB 45DP-FB / [6797] 9.9 [0.9] 2 27 /4 x 8 /8 x /2 [705x460x] /8 [5] 5/8 [6] VEB 60DP-FB [786] [0.9] 2 27 /4 x 8 /8 x /2 [705x460x] /8 [5] 5/8 [6] VEB 90DP-FB [856]. [.2] 2 2 5/8 x 8 /8 x /2 [829x460x] /8 [5] 5/8 [6] VEB 220DP-FB [976] 4. [.2] 2 2 5/8 x 8 /8 x /2 [829x460x] 2 /8 [29] 2 /2 [] Note: Power supply for VEB 68DP-FB to 95DP-FB is hz.

6 MATCH SYSTEM COOLING PERFORMANCE DATA Single Cond. Unit Evap. Blower Std. Capacity MBH Air On Evap. Air Temperature On Condenser Coil - F Flow cfm ACCS 68P HEB 68DP ACCS 8P HEB 8DP ACCS 95P HEB 95DP ACCS 08P ACCS 25P ACCS 45P ACCS 60P ACCS 90P ACCS 220P ACCS 250P HEB 08DP VEB 08DP HEB 25DP VEB 08DP HEB 45DP VEB 45DP HEB 60DP VEB 60DP HEB 90DP VEB 90DP HEB 220DP VEB 220DP EB 250DP VEB 250DP ACCS 290P EB 290DP ACCS 20P EB 20DP ACCS 80P EB 80DP WB Temp. F Total MBH¹ 75 F 95 F 5 F Sens MBH² kw³ Total MBH¹ Notes :.) Ratings are gross capacities - for net capacities, deduct evaporator blower motor heat. 2.) At 80 F [26.6 C] air on evaporator..) Compressor kw input. Sens MBH² kw³ Total MBH¹ R407C Sens MBH² kw³ - 6 -

7 MATCH SYSTEM COOLING PERFORMANCE DATA Single Cond. Unit Evap. Blower Std. Capacity MBH Air On Evap. Air Temperature On Condenser Coil - F Flow cfm ACCS 45P EB 45DP ACCS 480P EB 480DP ACCS 50P EB 50DP ACCS 570P EB 570DP ACCS 640P EB 640DP ACCS 700P EB 700DP ACCS 760P EB 760DP ACCS 800P EB 800DP ACCS 890P EB 890DP ACCS 960P EB 960DP ACCS 020P EB 020DP ACCS 40P EB 40DP ACCS 40P EB 40DP ACCS 520P EB 520DP WB Temp. F Total MBH¹ 75 F 95 F 5 F Sens MBH² kw³ Total MBH¹ Sens MBH² kw³ Total MBH¹ R407C Sens MBH² Notes :.) Ratings are gross capacities - for net capacities, deduct evaporator blower motor heat. 2.) At 80 F[26.6 C] air on evaporator..) Compressor kw input. kw³

8 BLOWER PERFORMANCE Available External Static Pressure - IWG - For Accessories And Duct System Static Resistance (Allowance Made For Wet Coil And Filters) RPM cfm Fan SP BHP SP BHP SP BHP SP BHP SP BHP VEB/HEB 08DP VEB/HEB 25DP VEB/HEB 45DP VEB/HEB 60DP VEB/HEB 90DP VEB/HEB 220DP VEB/HEB 250DP EB 290DP EB 20DP EB 80DP EB 45DP EB 480DP X 2 2 X 2 2 X 2 5 X 5 5 X 5 5 X 5 5 X 5 8 X 8 x 8 X X X

9 BLOWER PERFORMANCE Available External Static Pressure - IWG - For Accessories And Duct System Static Resistance (Allowance Made For Wet Coil And Filters) RPM cfm SP BHP SP BHP SP BHP SP BHP SP BHP EB 50DP EB 570DP EB 640DP EB 700DP EB 760DP EB 800DP EB 890DP EB 960DP EB 020DP EB 40DP EB 40DP EB 520DP Fan 500 X X X X X X X X X X X X

10 DIMENSIONAL DATA AIR COOLED CONDENSING UNITS ACCS 68P, 8P, 95P A B C D E Suction Size Liquid Size ACCS 68P 46 /2[8] 42 /6[084] 5[8] 29 7/6[748] 5 /4[400] 7/8[22]() /8[0]() ACCS 8P 48 /2[22] 44 /8[27] 9 5/6[49] /8[79] 20 5/6[56] 7/8[22]() /2[]() ACCS 95P 48 /2[22] 44 /8[27] 9 5/6[49] /8[79] 20 5/6[56] /8[29]() /2[]() ACCS 08P, 25P, 45P Suction Size Liquid Size ACCS 08P /8[29]() /2[]() ACCS 25P /8[5]() /2[]() ACCS 45P /8[5]() 5/8[6]() ACCS 60P, 90P, 220P, 250P, 290P A Suction Size Liquid Size ACCS 60P 40 /4[022] /8[5]() 5/8[6]() ACCS 90P 40 /4[022] /8[5]() 5/8[6]() ACCS 220P 48 /4[226] /8[29](2) /2[](2) ACCS 250P 48 /4[226] /8[5](2) /2[](2) ACCS 290P 48 /4[226] /8[5](2) 5/8[6](2) Note: ACCS 60P and 90P are single compressor unit. Note: All dimensions are in inches[mm]

11 DIMENSIONAL DATA AIR COOLED CONDENSING UNITS ACCS 20P, 80P, 45P A Suction Size Liquid Size ACCS 20P 48 /4[226] /8[5](2) 5/8[6](2) ACCS 80P 56 /4[429] /8[5](2) 5/8[6](2) ACCS 45P 56 /4[429] /8[5]() 5/8[6]() ACCS 480P, 50P, 570P Suction Size Liquid Size ACCS 480P /8[5]() 5/8[6]() ACCS 50P /8[5]() 5/8[6]() ACCS 570P /8[5]() 5/8[6]() ACCS 640P, 700P, 760P Suction Size Liquid Size ACCS 640P 5/8[4](2) 7/8[22](2) ACCS 700P 5/8[4](2) 7/8[22](2) ACCS 760P 5/8[4](2) 7/8[22](2) Note: All dimensions are in inches[mm]. - -

12 DIMENSIONAL DATA AIR COOLED CONDENSING UNITS ACCS 800P, 890P, 960P Suction Size Liquid Size ACCS 800P 5/8[4](2), /8[5]() 7/8[22](2), 5/8[6]() ACCS 890P 5/8[4](2), /8[5]() 7/8[22](2), 5/8[6]() ACCS 960P 5/8[4]() 7/8[22]() ACCS 020P, 40P, 40P, 520P A Suction Size Liquid Size ACCS 020P 45[68] 5/8[4]() 7/8[22]() ACCS 40P 45[68] 5/8[4]() 7/8[22]() ACCS 40P 50[80] 5/8[4](4) 7/8[22](4) ACCS 520P 50[80] 5/8[4](4) 7/8[22](4) Note: All dimensions are in inches[mm]

13 DIMENSIONAL DATA EVAPORATOR UNITS HEB 68DP, 8DP, 95DP A B C D E F HEB 68DP 20[508] 46[68] 24[60] [0] /8[289] 6 /2[49] HEB 8DP 20[508] 46[68] 24[60] [0] /8[289] 6 /2[49] HEB 95DP 2[584] 46[68] 0[762] 5 /2[94] /2[4] 5 /4[87] HEB 08DP, 25DP, 45DP, 60DP, 90DP, 220DP A B C D E F HEB 08DP 27[686] 50[270] [88] 6[406] /2[4] 2 /4[540] HEB 25DP 27[686] 50[270] [88] 6[406] /2[4] 2 /4[540] HEB 45DP 27[686] 50[270] [88] 6[406] /2[4] 24 /4[66] HEB 60DP 29[77] 58[47] 40[06] 8 /2[470] 6[406] 24 /8[69] HEB 90DP 29[77] 58[47] 40[06] 8 /2[470] 6[406] 24 /8[69] HEB 220DP 29[77] 78[98] 40[06] 8 /2[470] 6[406] 0[762] Note: HEB 220DP comes with double circuitry. EB 250DP, 290DP, 20DP, 80DP, 45DP A B C D E F EB 250DP 29[77] 78[98] 40[06] 8 /2[470] 6[406] 0[762] EB 290DP 8[965] 84[24] 45[4] 7[42] 9[48] /2[85] EB 20DP 8[965] 84[24] 45[4] 7[42] 9[48] /2[85] EB 80DP 48[29] 84[24] 45[4] 22[559] 9[48] 7[940] EB 45DP 48[29] 84[24] 45[4] 22 /2[572] 22 /2[572] 7[940] Notes. :.) All dimensions are in inches[mm]. 2.) Units shown are right hand piping connection. - -

14 DIMENSIONAL DATA EB 480DP, 50DP, 570DP, 640DP, 700DP, 760DP A B C D E F EB 480DP 68[727] 84[24] 66[676] 25[65] 25[65] 4[864] EB 50DP 68[727] 84[24] 66[676] 25[65] 25[65] 4[864] EB 570DP 68[727] 84[24] 66[676] 25[65] 25[65] 4[864] EB 640DP 78[98] 84[24] 66[676] 28[7] 28[7] 4[864] EB 700DP 78[98] 84[24] 66[676] 28[7] 28[7] 4[864] EB 760DP 78[98] 84[24] 66[676] 28[7] 28[7] 4[864] EB 800DP, 890DP, 960DP, 020DP, 40DP, 40DP, 520DP A B C D E F G EB 800DP 62[575] 98[2489] 80[202] /2[800] /2[800] 9[99] 7[42] EB 890DP 62[575] 98[2489] 80[202] /2[800] /2[800] 9[99] 7[42] EB 960DP 62[575] 98[2489] 80[202] /2[800] /2[800] 9[99] 7[42] EB 020DP 62[575] 98[2489] 80[202] 5 /2[902] 5 /2[902] 9[99] 4[56] EB 40DP 62[575] 98[2489] 80[202] 5 /2[902] 5 /2[902] 9[99] 4[56] EB 40DP 70[778] 8[2997] 86[284] 40[06] 40[06] 9[99] 4[56] EB 520DP 70[778] 8[2997] 86[284] 40[06] 40[06] 9[99] 4[56] VEB 08DP, 25DP, 45DP, 60DP, 90DP, 220DP, 250DP A B C D E F VEB 08DP 54 /2[84] 52[2] 25[65] 5 /2[94] /2[4] 4 /4[75] VEB 25DP 54 /2[84] 52[2] 25[65] 5 /2[94] /2[4] 4 /4[75] VEB 45DP 54 /2[84] 52[2] 25[65] 5 /2[94] /2[4] 4 /4[75] VEB 60DP 57 /2[46] 58 /2[486] 28[7] 8 5/8[47] 6[406] 5[8] VEB 90DP 57 /2[46] 58 /2[486] 28[7] 8 5/8[47] 6[406] 5[8] VEB 220DP 58 /4[492] 8 /2[2070] 28[7] 8 5/8[47] 6[406] 24 /4[629] VEB 250DP 58 /4[492] 8 /2[2070] 28[7] 8 5/8[47] 6[406] 24 /4[629] Notes. :.) All dimensions are in inches[mm]. 2.) Units shown are right hand piping connection

15 DIMENSIONAL DATA FREE BLOW TYPE EVAPORATOR BLOWER UNIT VEB 68DP-FB, 8DP-FB, 95DP-FB, 08DP-FB, 25DP-FB, 45DP-FB, 60DP-FB, 90DP-FB, 220DP-FB For Access To Internal Components.) Unscrew bolts at return air grille, remove grille and access to filters and coil. 2.) Unscrew bolts for blower section panel push panel up and remove panel for access to blower and drive assembly..) Unscrew bolts for bottom panel, push panel up and access to compressor(s), condenser(s) and controls. A B *C P VEB 68DP-FB 48 [29] 22 [559] 79 [2007] 29 [77] VEB 8DP-FB 48 [29] 22 [559] 79 [2007] 29 [77] VEB 95DP-FB 48 [29] 22 [559] 79 [2007] 29 [77] VEB 08DP-FB 56 [422] 24 [60] 8 [2057] 29 [77] VEB 25DP-FB 6 [549] 24 [60] 8 [2057] 29 [77] VEB 45DP-FB 6 [549] 24 [60] 8 [2057] 29 [77] VEB 60DP-FB 6 [549] 0 [762] 86 [284] 29 [77] VEB 90DP-FB 72 [829] 0 [762] 86 [284] [88] VEB 220DP-FB 72 [829] 0 [762] 86 [284] [88] Note: All dimensions are in inches[mm]. *Add 0 [25mm] to the units height if autotransformer are required. TYPICAL WIRING SCHEMATIC LIMITS AND CORRECTION FACTORS LIMITATION (AIR TEMPERATURE F) DB WB Indoor MAX MIN Outdoor MAX. 5 - MIN CORRECTION FACTORS To correct for variation in air flow, use this multiplier. Air Flow Variation Total Capacity Sensible Capacity To correct for altitude, use this multiplier. Altitude Above Sea Level - ft Cooling Capacity To correct sensible capacity for varying dry bulb. Dry Bulb Wet Bulb Note: If the capacity after multiplying the sensible with the correction factor exceed the total capacity, then the sensible must be equal to the total

16 Malaysia Lot , Kidamai Industrial Park, Bukit Angkat, 4000 Kajang, Selangor Darul Ehsan, Malaysia Tel: Fax: China No. Dunham-Bush Road, Laishan District, Yantai, Shandong Province, China Tel: Fax: United Kingdom 8 Downley Road, Havant, Hampshire, England PO9 2JD Tel : Fax: United Arab Emirates Al Murad Tower, Office 506 Al-Barsha, P. O. Box # 0922, Dubai, UAE Tel: Fax: South Africa No. 57 Sovereign Drive Route 2 Corporate Park Irene, Pretoria South Africa Tel: Fax: Singapore 2, Kallang Pudding Road #07-07, Mactech Industrial Building, Singapore 4907 Tel: Fax: Vietnam 0th Floor, Nam A Bank Tower, Cach Mang Thang 8 Street, District, Ho Chi Minh City, Vietnam TeL : Fax : Indonesia APL Tower, Central Park Podomoro City th 9 Floor T2, T, T5 Jl. Let. Jend. S. Parman Kav. 28 Jakarta Barat 470, Indonesia Tel. : Fax. : Please Scan Here for quick link to Dunham-Bush website info@dunham-bush.com Products that perform...by people who care Manufacturer reserves the right to change specifications without prior notice. M-S-06C-2

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

ACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform...

ACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform... ACPSB-P Series Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R R407C Products that perform...by people who care NOMENCLATURE 6 AC P S B 435 P - Q P 6-60 Hz Blank - 50Hz Blank P - R - R407C

More information

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s) NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

engineering guide Air-Cooled Self-Contained Units

engineering guide Air-Cooled Self-Contained Units engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

AIR-COOLED CONDENSING UNITS

AIR-COOLED CONDENSING UNITS TECHNICAL GUIDE TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS YH-07 thru -25 and YJ-10 thru -20 CONDENSING UNIT MODELS PH-07 thru -20 and PJ-15 thru -20 HEAT PUMP UNIT

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

TECHNICAL GUIDE. Description PREDATOR SERIES R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS

TECHNICAL GUIDE. Description PREDATOR SERIES R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS Description TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS PREDATOR SERIES YC090-300 and YD120-240 CONDENSING UNIT MODELS PC090-180 and PD180-240 HEAT PUMP UNIT MODELS

More information

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration

More information

AIR-COOLED CONDENSING UNITS

AIR-COOLED CONDENSING UNITS TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS YH-07 thru -25 and YJ-10 thru -20 CONDENSING UNIT MODELS PH-07 thru -15 and PJ-15 thru -20 HEAT PUMP UNIT MODELS NH-07 thru

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS HIEER : 3-25 Tons PRODUCT DATA BOOK Introduction Roof Top Package units have been developed & produced to provide not only the ultimate indoor comfort, but also to guarantee long

More information

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES 530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

TECHNICAL GUIDE. Description PREDATOR SERIES R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS

TECHNICAL GUIDE. Description PREDATOR SERIES R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS PREDATOR SERIES YC090-240 and YD120-240 CONDENSING UNIT MODELS PC090-240 and PD180-240 HEAT PUMP UNIT MODELS NC090-240 and

More information

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204 TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS D1EG/D1EE036, 048, & 060 3, 4, AND 5 NOMINAL TONS 11-11.5 SEER FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. GENERAL YORK Model DEE/DEG units are

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

IDENTIFICATION ACCESSORIES DESCRIPTION

IDENTIFICATION ACCESSORIES DESCRIPTION Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1 IDENTIFICATION

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Catalogue. Large Commercial Split System. Split System Tons RAUP/TTV Models 50 Hz. August 2005 SSA5-PRC003-EN

Product Catalogue. Large Commercial Split System. Split System Tons RAUP/TTV Models 50 Hz. August 2005 SSA5-PRC003-EN Product Catalogue Large Commercial Split System Split System 23-55 Tons RAUP/TTV Models 50 Hz August 2005 SSA5-PRC003-EN 2 American Standard Inc. 2005 SSA5-PRC 003-EN Contents Model Number Description

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information