ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)
|
|
- Shanna Eaton
- 6 years ago
- Views:
Transcription
1 -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care
2 NOMENCLATURE AC P S E 435 P HP G Q Air Cooled Packaged Scroll Compressor Generation Blank Q R40a Blank HP - Standard - Special - Cooling only - Heat Pump Nominal Capacity (MBH) Propeller Fan GENERAL DESCRIPTION The -P series with new features is suitable for hotel, office, hospital, school, factory and supermarket applications. The low noise and compact series are completely leak tested, evacuated, dehydrated and charged with refrigerant prior to shipment. REFRIGERANT R40A -P series uses the environmentally friendly refrigerant, R40A in each system. Zero ozone depletion potential. HERMETIC SCROLL COMPRESSOR(S) Reliability No contact scroll design that minimizes friction, increases volumetric efficiency and reduces vibration, thus longer service life. Suction gas cooled motor. Low Power Consumption: High EER. No crankcase heater required. CLASS F INSULATION CONDENSER FAN MOTOR Extra safety margin and longer motor life even in extreme operating conditions. IP 55 construction ensure extra motor protection ( 68P to 50P). Low motor speed at 950 rpm ensures quiet condenser fan operation. MULTIPLE COMPRESSOR ( 0P and above) By cycling off compressor operation to match building load, no energy is being wasted when room load requires lesser cooling capacity. No total shut down when servicing or repairing a faulty compressor. EFFICIENT CONDENSER COIL Staggered row of 3/8 OD inner groove tubes with 5 to 30% more surface area guarantee better heat transfer. Mechanically expanded into die-formed corrugated aluminum fins. Integral subcooling circuit to maximize efficiency. Leak and pressure tested to 650 psig. - -
3 GENERAL DESCRIPTION SAFETY CONTROL High-low pressure cutout to protect compressor from high discharge pressure and system leakage. FULLY LEAK TESTED REFRIGERANT CIRCUIT Compressor, condenser coil, filter drier, sightglass, thermo-expansion valve, distributor and evaporator coil is brazed in complete sealed loop. Leak and pressure tested at 450 psig. Pressure ports are provided on the discharge, liquid and suction line. Evacuated, dehydrated and charge with refrigerant gas prior to shipment. CASING Constructed from heavy gauge galvanized steel. Panels are painted with epoxy powder paint for excellent finish, weatherability and corrosion resistance. Evaporator section is insulated with x / lb per.cu.ft of linacoustic fibreglass. EFFICIENT EVAPORATOR COIL Independent thermal expansion valve with external equalizer for better refrigerant control and wider load condition. Leak and pressure tested to 650 psig Evacuated, dehydrated and charged with refrigerant gas. DRIVE PACKAGE AND BLOWERS Belt driven drive package offers flexibility on various air flow rate and various static pressure applications ( 60P and above). Single large diameter double inlet double width blowers (AMCA certified) reduce the noise level and eliminates the need for common transition and eliminates air unbalance. FILTERS thick with side loading for model 30P to 45P. thick with side loading for model 60P and above. OPTIONAL ACCESSORIES FEATURES Factory wired starters - DOL for compressors and fan motors. - Auto-transformer for compressors. Suction stop valve(s), discharge stop valve(s) and liquid stop valve(s). Fan staging ( 60P and above) of multiple fans for head pressure control. Thermostat. Hydrophilic fins or copper fins for better corrosion resistance. Hot gas by pass for low load and low ambient conditions. Hot water heating coils. Electric heaters
4 PHYSICAL SPECIFICATIONS COOLING ONLY Model 30PG 40PG 50PG 68PG 8PG 95PG 08PG 5PG 45PG 60PG 90PG 0PG 50PG 90PG 30PG 380PG 435PG 480PG 50PG 570PG 640PG 700PG 760PG 800PG 890PG 960PG 00PG 40PG 340PG 50PG EER Total Cooling Capacity Compr. Condenser Coil Condenser Fan Evaporator Blower Airflow R40A Face Size Mtr. Row/ Mtr hp Standard (Nominal) Qty Area Inch Max FPI (Qty) Size ft² (Qty) HP MBH [kw] CFM m³/hr Evaporator Coil Face Row/ Area FPI ft² Air Filter Size Inches (Qty) R40A Charge Estimated Lbs Per System (Qty) Unit Weight lbs /6 8 / / 6x5x /6 8 / / 0x5x /4 0 / / 0x5x / / / / / / 6x5x 0x5x 6x5x 0x5x 6x5x 0x5x Sound Pressure Level ± db(a) / / 0x5x / / 0x5x / / 0x5x /6 5x / / 5x / /6 5x / 0x0x 0x5x 0x0x 0x5x 0x0x 0x5x /6 8x / 5x5x /6 8x / 5x5x /4 (3) (3) 8x / /4 (3) (3) 8x / /6 (3) (3) 450x / /4 500x / /6 500x / /4 500x / / 3.5 / 560x / /4 3.5 / 560x / / 3.5 / 560x / /6 3.5 / 630x / /4 3.5 / 630x / /6 3.5 / 630x / /6 3.5(6) /(6) 70x / 6x5x 0x5x 6x0x(3) 0x0x(6) 6x0x(3) 0x0x(6) 0x0x 0x5x(5) 5x5x 0x0x 0x5x(5) 5x5x 0x0x 0x5x(5) 5x5x 0x0x 0x5x(8) 0x0x 0x5x(8) 0x0x 0x5x(8) 0x0x 0x5x(9) 5x5x 0x0x 0x5x(9) 5x5x 0x0x 0x5x(9) 5x5x 0x0x() 0x5x(8) (3) (3) (3) (3) /4 3.5(6) /(6) 70x / 0x5x(0) 6.5(3) /6 3.5(6) /(6) 800x / /6 3.5(6) /(6) 800x / 0x0x(8) 0x5x(6) 0x0x(8) 0x5x(6) 46.9(3) Notes:. Ratings are based on nominal airflow with on evaporator dry/wet bulb temperatures of 80/67 o F (7/9.4 o C) and condenser entering air temperature of 95 o F(35 o C).. Ratings are gross capacities. For net capacity deduct evaporator blower motor heat. 3. EER published as above is gross EER. 4. For alternate blower, please consult factory. 5. Sound Pressure Level is calculated based on nominal airflow at external static pressure of 0.5" WG (Model 30-45) /.5 WG (Model 60-50), 3m (9.8ft) distance away from unit at free field. Unit supply and return are assumed to be entirely insulated. The actual sound at field could be affected by the supply and return duct break out noise
5 PHYSICAL SPECIFICATIONS HEAT PUMP Model EER COP Total Cooling Capacity Total Heating Capacity Compr. Condenser Coil Condenser Fan Evaporator Blower Airflow R40A R40A Size Mtr Mtr. Face Row/ Standard (Nominal) Qty Inch hp Max Area ft² FPI Size (Qty) (Qty) HP MBH [kw] MBH [kw] CFM m³/hr Evaporator Coil Face Area ft² Row / FPI Air Filter Size Inch R40A Charge Estimated Lbs Per System (Qty.) Unit Weight lbs Sound Pressure Level ± db(a) 30PHPG 40PHPG 50PHPG 68PHPG 8PHPG 95PHPG 08PHPG 5PHPG 45PHPG 60PHPG 90PHPG 0PHPG 50PHPG 90PHPG 30PHPG 380PHPG 435PHPG 480PHPG 50PHPG 570PHPG 640PHPG 700PHPG 760PHPG 800PHPG 890PHPG 960PHPG 00PHPG 40PHPG 340PHPG 50PHPG / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / (3) (3) (3) (6) 3.5 (6) 3.5 (6) 3.5 (6) /5 /5 /5 (3) (3) (3) / / / / / / / (6) / (6) / (6) / (6) / 6x5x x / 0x5x x / 0x5x x / 6x5x 0x5x / 6x5x 0x5x / 6x5x 0x5x x x. 66 x / 0x5x x / 0x5x x / 0x5x x x / 0x0x 0x5x 5x / 0x0x 0x5x 5x / 0x0x 0x5x x x x x / 5x5x x.4 7 8x / 5x5x x x / 6x5x 0x5x 8x / 6x0x(3) 0x0x(6) 450x / 6x0x(3) 0x0x(6) 500x / 500x /6 500x /4 0x0x 0x5x(5) 5x5x 0x0x 0x5x(5) 5x5x 0x0x 0x5x(5) 5x5x 560x /0 0x0x 0x5x(8) 560x /4 0x0x 0x5x(8) 560x /4 0x0x 0x5x(8) 630x /4 630x /4 630x /4 0x0x 0x5x(9) 5x5x 0x0x 0x5x(9) 5x5x 0x0x 0x5x(9) 5x5x 70x / 0x0x() 0x5x(8) x x x x x 3. x x x x 48.8 x x x 58. x 3.6 x 65.4 x 77.8 x x x 59.4 x x / 0x5x(0) 3 x x / 0x0x(8) 3 x x5x(6) x x / 0x0x(8) 4 x x5x(6) Notes:. Cooling mode ratings are based on nominal airflow with on evaporator dry/wet bulb temperatures of 80/67 o F [7/9.4 o C] and condenser entering air temperature of 95 o F[35 o C].. Heating mode ratings are based on nominal airflow with on evaporator dry bulb temperatures of 70 o F [. o C] and condenser entering air temperature of 45 o F[7. o C]. 3. Ratings are gross capacities. For net cooling capacity deduct evaporator blower motor heat, net heating capacity to add blower motor heat. 4. EER and COP published as above are gross EER and COP. For heat pump model, cooling mode efficiency is rated in EER and heating mode efficiency is rated in COP. 5. For alternate blower, please consult factory. 6. Sound Pressure Level is calculated based on nominal airflow at external static pressure of 0.5" WG (Model 30-45) /.5 WG (Model 60-50), 3m [9.8ft] distance away from unit at free field. Unit supply and return are assumed to be entirely insulated. The actual sound at field could be affected by the supply and return duct break out noise
6 SYSTEM COOLING CAPACITY PERFORMANCE DATA COOLING ONLY Air On Evap. Cooling Ambient Air Temperature On Condenser Std. 95ºF [35ºC] 05ºF [4ºC] 5ºF [46ºC] Model EER Capacity WB Temp MBH CFM Total Sensible kw Total Sensible kw Total Sensible kw F C MBH kw MBH kw Input MBH kw MBH kw Input MBH kw MBH kw Input PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG PG Notes:. Ratings are based on 80 o F [7 o C] air on evaporator dry bulb temperature.. Ratings are gross capacities. For net capacity deduct evaporator blower motor heat. 3. kw input shown in the table is total compressor(s) power input
7 SYSTEM COOLING & HEATING CAPACITY PERFORMANCE DATA HEAT PUMP COOLING MODE Air On Evap. Cooling Ambient Air Temperature On Condenser Std. 95ºF [35ºC] 05ºF [4ºC] 5ºF [46ºC] Model EER Capacity WB Temp MBH CFM Total Sensible kw Total Sensible kw Total Sensible kw F C MBH kw MBH kw Input MBH kw MBH kw Input MBH kw MBH kw Input PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG PHPG Notes:. Ratings are based on 80 o F (7 o C) air on evaporator dry bulb temperature.. Ratings are gross capacities. For net capacity deduct evaporator blower motor heat. 3. kw input shown in the table is total compressor(s) power input
8 SYSTEM COOLING & HEATING CAPACITY PERFORMANCE DATA HEAT PUMP HEATING MODE Model 30PHPG 40PHPG 50PHPG 68PHPG 8PHPG 95PHPG 08PHPG 5PHPG 45PHPG 60PHPG 90PHPG 0PHPG 50PHPG 90PHPG 30PHPG 380PHPG 435PHPG 480PHPG 50PHPG 570PHPG 640PHPG 700PHPG 760PHPG 800PHPG 890PHPG 960PHPG 00PHPG 40PHPG 340PHPG 50PHPG Air On Evap. Heating Ambient Air Temperature On Condenser COP Std. Entering Air Temp 3ºF [-5ºC] 35ºF [.7ºC] 45ºF [7.ºC] 55ºF [.8ºC] Capacity MBH CFM DB Capacity kw Capacity Kw Capacity kw Capacity kw F C MBH kw Input MBH kw Input MBH kw Input MBH kw Input Notes:. Ratings are gross capacities. For net capacity add evaporator blower motor heat.. kw input shown in the table is total compressor(s) power input
9 BLOWER PERFORMANCE EVAPORATOR Model Airflow on Evaporator Blower Size Internal Static Pressure (ISP) External Static Pressure - in WG [Pa] 0.5 [5].0 [49].5 [374].0 [498] Standard (Qty) CFM m 3 Motor Hp Motor Hp /h in WG Pa RPM RPM RPM Motor Hp RPM Motor Hp (Qty) (Qty) 30P,000, ,400 35W 40P,400, ,300 35W 50P,600, ,300 35W 68P,000 3, ,00 750W 8P,400 4, ,50 750W 95P,600 4, , W Not Applicable 08P 3,00 5, ,50 600W, W 5P 3,500 5, , W, W 45P 4,000 6, ,00 750W, W Not Applicable Not Applicable 60P 4,600 7, , P 4,800 8, ,00 4.0, 4.0 0P 5,400 9, , , P 6,400 0, P 7,500, P 8,000 3, P 9,00 5, P,500 9, P,000 0, P 4,000 3, P 5,000 5, P 6,000 7, P 7,00 9, P 8,000 30, P 9,600 33, P,000 35, P 3,000 39, P 5,800 43, P,400 44, P 3,000 54, P 36,000 6, Notes:. Internal static pressure (ISP) includes pressure drops through evaporator coil, standard filter and unit casing.. Direct driven fan for model 30 to 45. Motor power in Watt. 3. Please consult factory for areas shaded in grey and ESP exceeds the above table. LIMITS AND CORRECTION FACTORS OPERATING LIMITS COOLING (AIR TEMPERATURE F) DB WB MAX. 5 - OUTDOOR MIN HEATING (AIR TEMPERATURE F) DB WB MAX OUTDOOR MIN. 5 - CORRECTION FACTORS To correct for variation in air flow, use this multiplier AIR FLOW VARIATION TOTAL CAPACITY SENSIBLE CAPACITY To correct for altitude, use this multiplier AIR ABOVE SEA LEVEL - FT COOLING CAPACITY
10 DIMENSIONAL DATA 30P, 40P MODEL A B 30P 3 [83] 6 [406] 40P 40 [06] 0[508] 50P 68P, 8P, 95P Note: All dimensions are in inches [mm]
11 DIMENSIONAL DATA 08P, 5P 45P 60P, 90P, 0P MODEL A STANDARD RUBBER 60P 3 / [343] 6 / [49] 90P 3 / [343] 6 / [49] 0P 3 / [343] 6 / [49] Note: All dimensions are in inches [mm]. - -
12 DIMENSIONAL DATA 50P, 90P MODEL A STANDARD RUBBER 50P 5 3/4 [400] 8 3/4 [476] 90P 5 3/4 [400] 8 3/4 [476] 30P, 380P, 435P MODEL A B C STANDARD RUBBER 30P [559] 9 [483] 7 3/4[45] 8 3/4 [476] 380P [559] 9 [483] 7 3/4[45] 8 3/4 [476] 435P / [57] / [57] 7 [43] 8 [457] 480P, 50P, 570P MODEL A STANDARD RUBBER 480P 8 [457] 9 [483] 50P 8 [457] 9 [483] 570P 8 [457] 9 [483] Note: All dimensions are in inches [mm]. - -
13 DIMENSIONAL DATA 640P, 700P, 760P 800P, 890P, 960P Note: All dimensions are in inches [mm]
14 DIMENSIONAL DATA 00P, 40P MODEL A B C 00P 6 [946] [835] 4 [067] 40P 35 [348] 30 [339] 50 [70] 340P, 50P Note: All dimensions are in inches [mm]
15 ELECTRICAL DATA Model 30P 40P 50P 68P 8P 95P 08P 5P 45P 60P 90P 0P 50P 90P 30P 380P 435P 480P 50P 570P 640P 700P 760P 800P 890P 960P 00P 40P 340P 50P Qty Compressor Compressor Rating Condenser Fan Model ZP3K3E- TFD-593 ZP4K3E- TFD-593 ZP5K5E- ZP7KCE- ZP83KCE- ZP9KCE- ZP04KCE- ZPKCE- ZP37KCE- ZP54KCE- ZP8KCE- ZP04KCE- ZPKCE- ZP37KCE- ZP54KCE- ZP8KCE- ZP37KCE- ZP54KCE- ZP8KCE- ZP54KCE- ZP8KCE- ZP54KCE- ZP8KCE- ZP54KCE- ZP8KCE- ZP54KCE- ZP54KCE- ZP8KCE- ZP8KCE- ZP54KCE- ZP54KCE- ZP8KCE- ZP54KCE- ZP8KCE- ZP8KCE- ZP54KCE- ZP8KCE- Power Supply MRA (Each) NRA (Each) LRA (Each) Qty Mtr. HP (Each) Evaporator Blower (Nominal) Mtr Mtr FLA Qty (Med HP) Mtr FLA Mtr LRA Qty Evaporator Blower (Max) Mtr (Max HP) Mtr FLA Mtr LRA Unit Rating (Nominal Evap.) Unit Rating (Max Evap.) FLA MCA MFS FLA MCA MFS x6.0 x4.7 x35.0 /5.97 NA NA NA NA NA NA NA NA x8.0 x6.0 x48.0 /5.97 NA NA NA NA NA NA NA NA x0.0 x6.9 x5.5 /5.97 NA NA NA NA NA NA NA NA x5.0 x9.8 x NA NA NA NA NA NA NA NA x5.0 x.7 x0.0.0 NA NA NA NA NA NA NA NA x6. x.4 x0.0.0 NA NA NA NA NA NA NA NA x8. x4.3 x8.0.0 NA NA NA NA.0 x.6 x6.6 x NA NA NA NA.0 x5.0 x8.3 x8.0.0 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA x3.0 x0.8 x x34.0 x.3 x x8. x4.3 x x.6 x6.6 x x5.0 x8.3 x x3.0 x0.8 x x34.0 x.3 x x5.0 3x8.3 3x x3.0 3x0.8 3x x34.0 x.3 x x3.0 x0.8 x40.0 3x34.0 3x.3 3x x3.0 4x0.8 4x / x34.0 x.3 x / x3.0 x0.8 x40.0 4x34.0 4x.3 4x / x3.0 x0.8 x / x3.0 4x0.8 4x40.0 x34.0 x.3 x74.0 x34.0 x.3 x74.0 x3.0 x0.8 x / x3.0 6x0.8 6x / x34.0 x.3 x / x3.0 4x0.8 4x40.0 6x34.0 6x.3 6x / x34.0 x.3 x / x3.0 6x0.8 6x40.0 8x34.0 8x.3 8x / Compressor NRA value is based on the following condition: Evaporating temperature: 45 F, Condensing temperature: 30 F, Subcooling: 8.3K, Superheat:.K, Ambient Temperature: 95 F" - 5 -
16 TYPICAL WIRING SCHEMATIC With IEC Direct-On-Line (DOL) Option - 6 -
17 GUIDE SPECIFICATIONS General Air cooled packaged unit shall include compressor(s), evaporator and condenser coils with fans, refrigeration piping, electrical components and enclosing cabinet in one piece. The units shall be factory assembled, internally wired, fully refrigerant charged with R40A and are suitable for outdoor installation on ground level with ducted system. The units shall be capable to operate up to 5 o F [46 o C] ambient temperature without failure. Cabinet The unit cabinet shall be constructed from heavy gauge galvanized steel with epoxy painted for excellent finished, weatherability and corrosion resistance up to 000 hours salt spray test according to ASTM B-7. Evaporator section shall be of 5mm [ inch] thick single skin and lined with minimum lbs/ft 3 [3kg/m 3 ] density having thermal conductivity of W/m.K [0.4Btu.in/ft.h. o F] acoustical fiberglass insulation. The insulation shall have fire resistant of Class O (BS 476 Part 6, 7). Access doors shall be provided for easy service and maintenance of unit internal parts. 3 Compressor & Refrigeration Piping Compressor(s) shall be scroll, refrigerant gas cooled and mounted on the base via vibration isolators.,, 3 or 4 refrigeration circuits shall be piped with copper tubing and include expansion valve with external equalizer, filter dryer, sight glass, pressure fittings of manual reset high pressure control and auto reset low pressure safety cutouts as well as charging/access ports in each circuit. The compressors comply with the internationally recognized standards CE and UL. 4 Evaporator Coil Evaporator coil shall be of draw through air design for uniform air distribution. The evaporator coil shall be quality construction of staggered row of 3/8 OD (model P) and / OD (model P) seamless copper tube, mechanically bonded to aluminium fins with galvanized coil plates. The coil shall be factory leak and pressure tested to 650psig [45 bar] under water. A galvanized and painted drain pan shall be provided to cover the entire coil area. The drain pan shall be designed to incorporate sloped gutter for complete condensate removal. 5 Evaporator Blower and Motor Evaporator blower shall be direct-driven (model 30-45P) and belt driven (model 60P and above), double-inlet-double-width (DIDW) forward curved. All blowers are statically and dynamically balanced to ensure quiet operation and smooth performance. Heavy-duty V-belt fan drive with cast iron pulleys keyed and secured to the blower shaft shall be provided (model 60P and above). Motors shall be of totally enclosed fan cooled (TEFC) with IP55 enclosure rating, 4-poles with class F insulation. Motors shall be mounted to an adjustable motor frame. Motor pulleys shall be cast iron, keyed and secured to the motor shaft (model 60P and above). 6 Condenser Coil Condenser coil shall be air cooled with integral sub-cooling circuit, constructed from staggered row of 3/8 OD inner grooved seamless copper tube, mechanically bonded to aluminium fins with galvanized coil plates. The coil shall be factory leak and pressure tested to 650psig [45 bar] under water. 7 Condenser Fan and Motor Condenser fan shall be direct driven propeller type discharging air vertically upward. Condenser fans shall be constructed of corrosion resistant blades and are statically and dynamically balanced. Condenser fan motors shall be of totally enclosed fan cooled (TEFC) with IP55 enclosure rating, 6-poles with class F insulation and wired to unit control panel. The condenser fan assembly shall be provided with heavy gauge and rust resistant steel wire fan guard. 8 Filters Units shall be provided with (model 30P to 45P) and (model 60P and above) thick washable pleated filters having average arrestance efficiency of 70% (model 30P to 45P) and 75% (model 60P and above) as per ASHRAE Standard 5. (or equivalent) with side loading. 9 Control Panel The unit mounted control panel enclosure shall be constructed from heavy gauge galvanized steel with epoxy painted for excellent finished, weatherability and corrosion resistance. The enclosure shall conform to IP54. Hinged and lock type access door shall be provided for easy access and security. The control panel shall be wired without starter and control
18 GUIDE SPECIFICATIONS 0 Options 0. Stainless Steel Drain Pan A stainless steel condensate drain pan shall be provided for the evaporator section in lieu of standard galvanized and painted drain pan. 0. Hot Gas Bypass The refrigerant circuit (applicable to first in last out refrigeration system only) shall be provided with a hot gas bypass system for low load and low ambient condition (evaporator freeze protection). 0.3 Evaporator Coil Fin Materials In lieu of standard aluminium fin, alternative fin material and/or protective coating include, Hydrophilic coated aluminium fin Copper Fin Aluminium fin with Airestec coating Copper fin with Airestec coating 0.4 Condenser Coil Fin Materials In lieu of standard aluminium fin, alternative fin material and/or protective coating include, Hydrophilic coated aluminium fin Copper Fin Aluminium fin with Airestec coating Copper fin with Airestec coating 0.5 Condenser Coil Guard Powder coated wire mesh guard shall be provided for better condenser coil protection. 0.6 High and Low Pressure Gauges Each compressor is provided with unit mounted pressure gauges to monitor high and low side operating pressure. 0.7 Discharge / Suction / Liquid Line Service Valves Service valves shall be provided at each refrigerant lines for service convenience. 0.8 Closed Cell Elastomer Insulation thick closed cell elastomer insulation (Insulflex ) shall be provided in lieu of standard fiberglass insulation. Closed cell elastomer insulation shall comply Class O (BS476 Part 6) and Class (BS476 Part 7) fire resistant standard. 0.9 Double Wall Fiberglass Casing (Evaporator Section) double wall fiberglass casing shall be provided in lieu of single skin fiberglass casing (model 60P and above). 0.0 Double Wall Polyurethane Casing (Evaporator Section) double wall polyurethane casing shall be provided in lieu of single skin fiberglass casing (model 640P and above) for superior thermal insulation. 0. Liquid Line Solenoid Valve (LLSV) Factory fitted liquid line solenoid valve shall be provided for each refrigeration circuit. 0. Hot Water Heating Coil Hot water coil shall be provided for heating purpose (hot water shall be field supplied). 0.3 Evaporator Blower Isolator Rubber or spring isolator shall be provided to dampen vibration caused by motor and blower (model 60P and above). 0.4 Replaceable Core Filter Drier Replaceable filter core drier shall be provided in lieu of standard filter drier for the convenience of filter drier s core replacement. 0.5 Stainless Steel Fasteners Stainless steel fasteners shall be provided in lieu of standard fasteners for corrosion resistance application. 0.6 Suction accumulator Suction accumulator shall be provided to prevent liquid refrigerant migration to compressor. 0.7 C-Channel Structural Steel Base (model P) 0.8 Belt Guard Belt guard shall be provided for belt and pulley s non- contact exposure. 0.9 Electric Heater Electric heater shall be provided for heating purpose. 0.0 Electronic Expansion Valve (EEV) In lieu of standard thermal expansion valve, EEV shall be provided for precise superheat control (energy saving). 0. IEC DOL ( Non UL) The unit mounted control panel enclosure shall be constructed from heavy gauge galvanized steel with epoxy painted for excellent finished, weatherability and corrosion resistance. The enclosure shall conform to IP54. Hinged and lock type access door shall be provided for easy access and security. The control panel shall be factory wired and shall include compressor, evaporator fan motor and condenser fan motor circuit breaker and contactors, compressor and evaporator fan motor thermal overload relays, anti-recycling time delay relay, control circuit fuse, power and control circuit terminal blocks and features 30V controls with V/ 3PH/50HZ (+Neutral) power supply
19 GUIDE SPECIFICATIONS 0. Carel Controller Panel mounted thermostat is provided for the unit to control and maintain the room temperature at a constant level or set point. 0.3 Indicating Lights Indication provided for high-presure trip and compressor run. 0.4 UVR/Phase Failure Protect Phase Failure Relay is provided for over voltage, under voltage and phase loss protection. 0.5 IP55 Control Panel In lieu of standard control panel, IP55 Control Panel with double layer access door shall be design in according to IP55 standard is provided 0. Vision 00i The unit shall be provided with Vision 00i control system with the following features, The control algorithm and parameters shall be stored in flash memory and EPROM of the controller and shall retain even in the event of power failures, without requiring a backup battery PGD Display Built in memory for data logging Temperature and humidity controlled Configurable by user Alarm status/display Analog input/output display Digital input/output status Remote start/stop input Digital input for customer input alarm General alarm output (dry contact) Self-diagnostics Security password access with multiple access level for advanced settings Unit status display 0.7 MODBUS RS485 MODBUS card can be added for BMS communication. VISION 00i controller must be selected for this features. 0.8 Lock Out Stop Emergency stop switch provided for Blower Fan. 0.9 Differential Pressure Switch for Evaporator Blower Differential pressure switch provided to interlock with the control circuit Voltmeter Voltmeter and selector switch provided for voltage display 0.3 Ammeter Ammeter and selector switch provided for current display. 0.3 Anti Recycle Timer Additional timer is added to prevent the compressor from starting for a period of time after it stops last Electric Heater Starter Contactor and circuit breaker provided for electric heater Low Ambient Kit Fan cyling for better performance during low ambient Compressor Soft Start Soft-Starter for compressors to reduce the staring current Door Interlock Main Incoming Isolator Incoming Isolator is provided for isolate the main incoming power supply to the unit BMS Box 0.38 Star Delta Starter Evaporator Motor Star Delta starting method available for Evaporator motor Nominal Evaporator Motor Soft Starter Soft-Starter available to reduce the starting current for Nominal Evaporator motor Max Evaporator Motor Soft Starter Soft-Starter available to reduce the starting current for Maximum sized Evaporator motor. 0.4 VFD for Condenser Motor Variable Frequency Drive (VFD) on condenser fan motors (base fans) with pressure transducer added for more accurate control VFD for Evaporator Motor Nominal HP Variable Frequency Drive (VFD) on Nominal Evaporator motor with pressure transducer VFD for Evaporator Motor Max HP Variable Frequency Drive (VFD) on Maximum Evaporator motor with pressure transducer VFD Box Control panel to mount Variable Frequency Drive (VFD) Crankcase Heater - 9 -
20 Malaysia Lot , Kidamai Industrial Park, Bukit Angkat, Kajang, Selangor Darul Ehsan, Malaysia Tel: Fax: China No. Dunham-Bush Road, Laishan District, Yantai, Shandong Province, China 4003 Tel: Fax: United Kingdom 8 Downley Road, Havant, Hampshire, England PO9 JD Tel : Fax: United Arab Emirates Office # 06, Fortune Executive Towers, Cluster T, Jumeirah Lake Tower Dubai, UAE Tel: Fax: South Africa No. 57 Sovereign Drive Route Corporate Park Irene, Pretoria South Africa Tel: Fax: Singapore Kallang Pudding Road #07-07 Mactech Building Singapore Tel: Fax: Vietnam Indonesia 0th Floor, Nam A Bank Tower, 0-03 Cach Mang Thang 8 Street, District 3, Ho Chi Minh City, Vietnam Tel: Fax: APL Tower, Central Park Podomoro City th 9 Floor T, T3, T5 Jl. Let. Jend. S. Parman Kav. 8 Jakarta Barat 470, Indonesia Tel: Fax: Please Scan Here for quick link to Dunham-Bush website info@dunham-bush.com Products that perform...by people who care Manufacturer reserves the right to change specifications without prior notice. M-S-05A-3
50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform...
ACPSB-P Series Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R R407C Products that perform...by people who care NOMENCLATURE 6 AC P S B 435 P - Q P 6-60 Hz Blank - 50Hz Blank P - R - R407C
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationR407C. ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz. Air Cooled Split Systems Cooling Capacity : 59 to 1327 MBH (17 to 389 kw)
ACCS-P, EB-DP, HEB-DP, VEB-DP Series 50Hz Air Cooled Split Systems Cooling Capacity : 59 to 27 MBH (7 to 89 kw) HEB-DP (Indoor) ACCS-P (Outdoor) VEB-DP (Indoor) R407C Products that perform...by people
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationChiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.
Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationRCD Air Cooled Condensing Unit (50/60 Hz)
Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationSCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS
SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More information1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationAIR COOLED CHILLERS WATER COOLED CHILLERS
AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with
More informationR6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY
TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility
More informationChiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw
Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationOEZ IEZ NOMENCLATURE STANDARD FEATURES FACTORY INSTALLED OPTIONS
Table of content Bulletin RP-EZ-2015-00 NOMENCLATURE STANDARD FEATURES FACTORY INSTALLED OPTIONS... 3... 4... 4 CAPACITY (COPELAND) IEZ/OEZ (013 to 120) HIGH TEMPERATURE, R-407C IEZ/OEZ (015 to 200) HIGH
More informationengineering guide Air-Cooled Self-Contained Units
engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TABLE OF CONTENTS NOMENCLATURE............................. 3 FEATURES.................................... 4 KV SERIES FEATURES.........................
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationPERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS
50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING
More informationCompresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW
Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationQ6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationSINGLE PACKAGE HEAT PUMPS
SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationNext-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. RU-RFH-1117A Replaces document RU-RFH-0917A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationTECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS
TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to
More informationNext-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. RU-RFH-0117A Replaces document RU-RFH-0516A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationLUI / LUO. Condensing Units
UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationWQL/WQH/WQRC 524 to 1204
Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features
More informationGUIDE SPECIFICATIONS CE Series Two Stage R-410A
GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationAIR-COOLED CONDENSING UNITS
TECHNICAL GUIDE TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS YH-07 thru -25 and YJ-10 thru -20 CONDENSING UNIT MODELS PH-07 thru -20 and PJ-15 thru -20 HEAT PUMP UNIT
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationGUIDE SPECIFICATIONS. ES Series R-410A
GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationHS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationAIR-COOLED CONDENSING UNITS
TECHNICAL GUIDE R-410A SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS YH-07 thru -25 and YJ-10 thru -20 CONDENSING UNIT MODELS PH-07 thru -15 and PJ-15 thru -20 HEAT PUMP UNIT MODELS NH-07 thru
More informationHS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationAir Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring CopelandTM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationVLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)
R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :
More informationPACKAGE AIR CONDITIONERS
PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0
More informationBVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS
BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationDCH Commercial Contents Standard Features Cabinet Features
DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8
More informationProduct Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)
SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationFORM NO. PTZ-806 REV. 1 HEAT PUMPS
FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationCAS. Product Specifications
CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 150 models Terminal
More informationOmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide
Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted
More informationYCUJ Millennium TM AIR COOLED CONDENSING UNIT
YCUJ Millennium TM AIR COOLED CONDENSING UNIT REFRIGERANT R407C COOLING CAPACITIES 348 kw to 760 kw The YCUJ range of Condensing Units are designed for direct expansion cooling and are usually used in
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationJT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and
More information