1 Bicon Cable Glands Transit Cable Products 2 Janes Court, Cambridge Cambridgeshire CB1 3JJ United Kingdom

2 Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with best-in-class cable and accessory solutions, based on state-of-the-art technology. Through two renowned commercial brands - Prysmian and Draka based in almost 50 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, systems and accessories - covering voice, video and data transmission. Drawing on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry. What links the oil and gas industry from end to end? Cable solutions to support the sector around the world In applications ranging from drilling, extraction and storage equipment to platform and processing facilities operation, Prysmian s state-of-the-art cable systems support many major customers in the oil, gas and petrochemical industry, along with related businesses. Whether they re deployed in Brazil, the Gulf of Mexico, the North Sea or South-East Asia, our cable solutions are proving their value in harsh offshore and onshore environments; helping customers minimize environmental impact and achieve sustainable, profitable growth. 2

3 Prysmian Group s dedicated Components facility based in Wrexham, Wales manufactures and supplies the market with products which are widely used in industrial, commercial and domestic power distribution systems. In addition it offers products for more specialist applications such as Utilities, Railways, Oil, Gas and Petrochemical, Hazardous Areas, Wind and Solar Energy. Today s BICON product ranges represent over 100 years of cable accessory development and quality engineering, building on the pedigree of our previous company names - going back to BICC. Of course Prysmian Group s Components products are the perfect installation accessory for the Company s vast range of quality, approved cables. Prysmian Group s comprehensive component product range includes: From its UK base, Prysmian Group s Components business is able to efficiently service the needs of its UK and overseas customers and offers a high level of pre-sales and post-sales customer service. For further information please contact: Sales Hotline: International Sales Office: BICON Cable Glands BICON Cable Cleats BICAST Joints & Terminations BICON Connectors and Tooling Flexo Modular Power Systems Flexo Rail products JEM Resin Connecta System Introduction to Bicon Cable Glands Prysmian Group s Components business unit, based in Wrexham, is the UK s most experienced manufacturer of Cable Glands. Bicon cable glands are supplied for use in both industrial and hazardous locations. Through many years of industry experience and working closely with our customers, Prysmian Group is able to offer glands to terminate all cable types on the market. As the world s number one manufacturer of cables, Prysmian Groups Bicon cable glands are designed and manufactured utilising all the knowledge of the critical requirements to safely terminate cables in all types of installations. Bicon Cable Glands are mechanical cable entry devices that attach and secure the end of a cable to an enclosure or directly into equipment providing for mechanical support, earth continuity and protection against the ingress of dust and moisture. Additionally, in hazardous areas they prevent the migration of gases and control and contain any potential explosions. The Bicon ranges of glands have been designed and tested with The Prysmian Group cable products. They are the recommended and preferred method of installation for all Prysmian and Draka cables. When installing fire resistant and Low Smoke Zero Halogen (LSOH) cables it is important that the accessories used meet the same performance requirements as the cable. Thus, the accessory does not impact on the system performance as a whole in the event of a fire. As the world market leader in both of these types of cables it is no surprise that the Prysmian Group is able to offer specific glanding solutions. Look out for the FP, Afumex, FT and Saffire logos in the catalogue which highlight these. Bicon LSOH industrial gland kits have been granted LUL approvals. These products are highlighted in the catalogue. Please note the relevant LUL APR Product ID numbers on the relevant pages. Bicon cable glands are manufactured in either aluminium, brass or nylon as standard. In the event that the installation requires electroless nickel plated brass these can also be supplied. Bicon glands have been used on a vast number of major electrical engineering projects including: Terminal 5 Heathrow, oil platforms in the North Sea, and power stations in the UK and Europe. 3

4 4 Transit Cable Products 2 Janes Court, Cambridge Cambridgeshire CB1 3JJ United Kingdom

5 Contents Industrial Glands LS0H or LSF materials Ingress Protection Index Industrial Glands Selector Industrial Glands Contents BW Gland Kit Indoor Cable Gland (KA410 Series) BW LSOH Gland Kit Indoor Cable Gland (420LSF Series) BWL Gland Kit Indoor Cable Gland (KJ417 Series) Nylon Cable Gland (403K Series) Nylon Cable Gland (FP250) A1/A2 Gland Kit Indoor / Outdoor Cable Gland (KM409 Series) A1/A2 LSOH Gland Kit Indoor / Outdoor Cable Gland (423LSF Series) AXT Gland Kit Indoor / Outdoor Cable Gland (423AX Series) CW Gland Kit Indoor / Outdoor Cable Gland (KA419 Series) CW-B Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KA419-B Series) CW-B LSOH Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KV419-B Series) CW LSOH Gland Kit Indoor / Outdoor Cable Gland (422LSF Series) CW-AL Gland Kit Indoor / Outdoor Cable Gland (KA422 Series) CW-AL LSOH Gland Kit Indoor / Outdoor Cable Gland (432LSF Series) CX Gland Kit Indoor / Outdoor Cable Gland (KA414 Series) CX-B Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KA414-B Series) E1W Gland Kit Outdoor Wet Area Cable Gland (KAA413 Series) E1W Gland Kit Outdoor Wet Area Cable Gland (KAA413 Series) E1W LSOH Gland Kit Outdoor Wet Area Cable Gland (421LSF Series) CW Integral Earth Gland Kit Indoor / Outdoor Cable Gland (419CE Series) CW-AL Integral Earth Gland Kit Indoor / Outdoor Cable Gland (454CE Series) CW-Dual Screen Gland Kit Concentric Bonding Cable Gland (422DA Series) Hazardous Glands Introduction to Hazardous Areas Barrier Glands & when required Hazardous gland selection chart Hazardous area gland contents Nylon Ex e Cable Gland (403AT Series) A2EX Ex d IIC / Ex e II Cable Gland(494AB Series) A2EX(NPT) Ex d IIC / Ex e II Cable Gland (494NE Series) A2EX Ex d IIC / Ex e II Cable Gland kit (KM494 Series) A2EX Ex d IIC / Ex e II Cable Gland kit (LOSH) (KCH494 Series) A2EXP Ex d IIC / Ex e II Dual Seal Cable Gland (495AB Series) A2EXP (NPT) Ex d IIC / Ex e II Dual Seal Cable Gland (495NE Series) A2EXP Ex d IIC / Ex e II Dual Seal Cable Gland Kit (KM495 Series) E1WF Ex d IIC / Ex e II Cable Gland (472AA Series) E1WF(NPT) Ex d IIC / Ex e II Cable Gland (472NP Series) E1WF Ex d IIC / Ex e II Cable Gland Kit (PVC) (KCA472 Series) E1WF Ex d IIC / Ex e II Cable Gland Kit (PCP) (KA472 Series) E1WF-Al Ex d IIC / Ex e II Cable Gland (455AA Series) E1WF-Al Ex d IIC / Ex e II Cable Gland Kit (KCA455 Series) E1XF Ex d IIC / Ex e II Cable Gland (473AA Series) E1XF(NPT) Ex d IIC / Ex e II Cable Gland (473NP Series) E1XF Ex d IIC / Ex e II Cable Gland Kit (PVC) (KCA473 Series) E1XF Ex d IIC / Ex e II Cable Gland Kit (PCP) (KA473 Series) E1W-XL Ex d IIC / Ex e II Cable Gland (474SW Series) E1W-XL (NPT) Ex d IIC / Ex e II Cable Glands (474NP Series) E1W-XL Ex d IIC / Ex e II Cable Gland Kit (KA474 Series) Excel Plus Ex d IIC / Ex e II Deluge Proof Cable Gland (493AB Series) Excel Plus (NPT) Ex d IIC / Ex e II Deluge Proof Cable Gland (493NE Series) Excel Plus Ex d IIC / Ex e II Deluge Proof Cable Gland Kit (KA493 Series) Barr-A Ex d IIC Cable Gland (424TA Series) Barr-W Ex d IIC Cable Gland (424TW Series) Barr-X Ex d IIC Cable Gland (424TX Series) Barr-PB Ex d IIC Cable Gland (424TP Series) Accessories Accessories Contents PVC Shrouds - UV Resistant PVC shrouds PCP Shrouds - Polychloroprene Shrouds LSOH Shrouds - Silicone LSOH Shrouds Locknuts - Brass, Nickel Plated Brass, Steel & Aluminium Insulated Adaptors Ex d Earthtags - Brass & Aluminium IP Washers - Nylon & Fibre Sealing Washers Anti-vibration Washers - Stainless Steel Serrated Washers Adaptors & Reducers Ex d

6 Gland Material Selection We use only the best quality extruded and forged materials to suit the varied requirements and conditions that our glands will encounter. Our brass Cable Glands are produced using material grade CuZn39Pb3 (CW614N) to EN and EN for guaranteed uniformity and strength. When increased environmental corrosion protection is required for our brass glands - we add an Electroless Nickel Plated finish to the external components. Where single core cables are supplied with aluminium armours we strongly recommend the use of aluminium glands to negate any possible bi-metallic corrosion - in these cases our glands are made from aluminium alloy grade AW 6082-T6 to EN which provides good corrosion resistance characteristics. LS0H or LSF materials Making the right choice! Low Smoke Zero Halogen materials known as LSOH, should be used in any environment where public safety is a consideration. These include locations such as offices, schools, stations or underground systems etc. Safety considerations have resulted in materials being developed and specified that, in a fire, will emit less of the harmful gases particularly smoke and halogens. The materials that do not emit any significant halogen gas and have reduced smoke emission properties are termed LS0H (Low Smoke Zero Halogen) - these materials must emit less than 0.5% Hydrogen Chloride (HCl). High levels of HCl has a damaging effect on the human respiratory system when inhaled, as well as being damaging to electronic circuits or machinery. Some materials are misleadingly labelled LSF (low smoke and fume) this does not indicate that they emit low HCl for example, a modified PVC could give off over 15% HCl and still be sold as LSF. However, Halogens are not alone in their tendency to produce toxic gases during combustion. There are many polymeric materials which, although halogen free, will also produce toxic by-products in the event of a fire. London Underground Specification (A3) states that combustible materials must not contain halogens, nitrogen or sulphur. Materials that do contain these elements must undergo additional testing to ensure compliance with the toxic emission potential requirements of BS6853. Nylon, for example, contains nitrogen which, during a fire, can produce toxic gasses such as ammonia, mixed oxides of nitrogen and small amounts of hydrogen cyanide. The materials used in Bicon LSOH accessories are not only halogen free but do not contain any other elements likely to result in toxic gas emission. As a result Bicon gland kits have been approved by LUL - look out for the LUL APR product number. 6

7 Introduction to Ingress Protection Index (EN 60529) 1st No. Protection against solids 2nd No. Protection against liquids 0 No-protection 0 No-protection 1 Ø 50mm Protected against solid bodies Larger than 50mm (e.g. Accidental contact with a hand) 1 Protection against vertically falling drops of water (Condensation) 2 Ø 12.5mm Protected against solid bodies Larger than 12mm (e.g. A finger of a hand) 2 Protected against drops of water falling at up to 15 from vertical 3 Ø 2.5mm Protected against solid bodies larger than 2.5mm (e.g. tools and wires) 3 Protected against drops of water up to 60 from vertical 4 Ø 1mm Protected against solid bodies larger than 1mm (e.g. fine tools and small wires) 4 Protected against projections of water from all directions 5 5 protected against dust (no harmful deposits) Protected against jets of water from all directions 6 6 Completely protected against dust Protected against powered jets of water from all directions 7 1m 15cm min Protection against the effects of immersion duration = 30mins 8 Protection against the effects of submersion agreed duration & depth Introduction to Deluge Testing DTS01 This test was developed by Shell & ERA Technology in 1991 to address the needs of the offshore sector where emergency deluge systems are commonly installed. The deluge test requires that glands are 1st pre-conditioned by exposure to vibration and thermal ageing at high humidity levels. The test then simulates the offshore deluge systems by using a specially designed deluge chamber with nozzles firing high pressure salt water at the glands for 3 hours. 7

8 Industrial Glands Selector Correctly selected and installed Cable Glands will attach and secure the end of a cable to an enclosure/ equipment providing for: Mechanical support Earth continuity Protection against ingress of dust Protection against ingress of moisture See Selection chart below for Industrial gland Selection Plus in Hazardous areas Prevents migration of gases Controls/contains explosions Go to page 36 for Hazardous gland selection INDUSTRIAL GLAND SELECTION CHART INDUSTRIAL CABLE GLAND REQUIRED No - Unarmoured IS THE CABLE ARMOURED Yes Non Armoured Glands Brass or Plastic Braid Armours Armour Type Cable 25mm Ø No Aluminium Wire Armour (AWA) Steel Wire Armour Mobile Equipment Fixed or Mobile Cable type & Diameter Fault Current Level Where is The gland Installed Yes Fixed Indoor Outdoor Wet Conditions Brass Does Customer Prefer Plastic or Brass CY, SY types < 21mm Ø All Braids Standard High Fault Current Level Plastic Standard FP200 < 12mm Ø High Brass E1W PVC shroud KAA413 Brass A1/A2 KM409 < 12mm Ø Upto 25mm Ø Aluminium CW KA422AL Brass BW KA410 Brass CW KA419 Brass E1W PCP shroud KA413 Brass A1/A2 LSOH Version 423LSF Nylon FP2520R / WFP 200 upto 12mm Nylon 403K Brass AXT AXT (pigtail earthing) Brass CX KA414 Aluminium CW LSOH Version 432LSF Aluminium CW + Integral Earth 454CE Brass BW LSOH Version 420LSF Brass CW LSOH Version 422LSF Brass CW + Integral Earth 419CE Brass E1W LSOH Version 421LSF 8

9 INDUSTRIAL GLANDS CONTENTS Location Armour Gland Page BW Gland Kit KA Indoors SWA BW LSOH Gland Kit 420LSF 11 BWL Gland Kit KJ A Type Nylon Gland 403K 13 Unarmoured A Type Nylon Gland for Fire alarm Cables FP A1/A2 Gland Kit (+ Nickel Plated Version) KM409 (V) 15 A1/A2 LSOH Gland Kit (+ Nickel Plated Version) 423LSF (V) 16 CY SY Braid AXT Gland Kit 423AX 17 CW Gland Kit (+ Nickel Plated Version) KA419 (V) 18 Industrial Outdoors SWA CW Gland Kit - Elongated Equipment Thread KA419B 19 CW-B LSOH Gland Kit - Elongated Equipment Thread KV419B 20 CW LSOH Gland Kit (+ Nickel Plated Version) 422LSF (V) 21 AWA CW Al Gland Kit KA CW Aluminium LSOH Gland Kit 432LSF 23 Braid CX Gland Kit KA CX Gland Kit - extended KA414B 25 E1W Gland Kit - PVC Shroud (+ Nickel Plated Version) KAA413 (V) 26 Wet Areas SWA E1W Gland Kit - PCP Shroud (+ Nickel Plated Version) KA413 (V) 27 E1W LSOH Gland Kit 421LSF 28 SWA CW Integral Earth Gland Kit 419CE 29 Hi Fault Current AWA CW Aluminium Integral Earth Gland Kit 454CE 30 Dual Copper Dual Screen Cable Gland Kit 422DA 31 9

10 INDUSTRIAL GLANDS BW Gland Kit Indoor Cable Gland (KA410 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Indoor type for SWA cable. Brass indoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables For use in dry, dust free situations Provides mechanical cable retention and electrical continuity via armour locking mechanism Kit comprises: BW Gland Brass Earth Tag Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS : 2005 Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Ø (A) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Max A/F (G) A/C (H) KA S M KA /1.25 M KA /1.6 M KA /2.0 M KA /2.0 M KA /2.5 M KA M KA S M KA M KA M85x

11 BW LSOH Gland Kit Indoor Cable Gland (420LSF Series) INDUSTRIAL GLANDS SUITABLE FOR USE WITH ALL LSOH STEEL WIRE ARMOURED CABLES Indoor type for LSOH SWA cable Brass indoor gland and LSOH accessories For galvanized-steel single-wire armour plastic or rubber LSOH sheathed cables For use in dry, dust free situations Provides mechanical cable retention and electrical continuity via armour locking mechanism Kit comprises: BW Gland Brass Earth Tag Brass Locknut LSOH Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 6724 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS : 2005 Service temperature range -20 C to +90 C Complies with LU Standard for installation in all sub-surface locations LUL APR Product ID 1968 Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Ø (A) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Max A/F (G) A/C (H) 420LSF-52 20S M LSF /1.25 M LSF /1.6 M LSF /2.0 M LSF /2.0 M LSF /2.5 M LSF M LSF-62 75S M LSF M

12 INDUSTRIAL GLANDS BWL Gland Kit Indoor Cable Gland (KJ417 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Indoor type for SWA cable. Three Part Gland with separate locking ring Brass indoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables For use in dry, dust free situations Provides mechanical cable retention and electrical continuity via armour locking mechanism Kit comprises: BW Gland Brass Earth Tag Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc : BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS : 2005 Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Ø (A) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Max A/F (G) A/C (H) KJ M KJ S M KJ /1.25 M KJ /1.6 M KJ /2.0 M KJ /2.0 M KJ s /2.5 M KJ /2.5 M KJ s M KJ M KJ S M KJ M KJ M85x KJ M90x

13 Nylon Cable Gland Cable Gland (403K Series) INDUSTRIAL GLANDS SUITABLE FOR USE WITH CIRCULAR UNARMOURED CABLES Suitable for indoor and outdoor applications. Suitable for use with all unarmoured circular cables. Cable Grab Claw, design - to grip cable firmly Available in four colours: black, red, white and grey. Supplied with locknut & entry thread seal Kit comprises: Nylon Gland Rubber entry thread seal Nylon lock nut Material: UL approved nylon 66 94V-2 IP 68 rated Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Cable Diameter Ø mm Hexagon Entry Thread Thread Length Protrusion Length (D) (E) (F) Min Max A/F (G) A/C (H) 403K* M16x K* M20x K* M25x K* M32x Replace * to specify colour: B=Black, W=White, R=Red, G=Grey 13

14 INDUSTRIAL GLANDS Nylon Cable Gland Cable Gland (FP250) SUITABLE FOR USE WITH FIRE ALARM CABLES Suitable for indoor and outdoor applications. Suitable for use with all Fire Alarm Cables Cable Grab Claw, design - to grip cable firmly Compressible entry thread seals moulded into gland body Available in two colours: red and white Supplied complete with locknut Kit comprises: Nylon Gland Nylon lock nut Material: Flame Retardent Nylon IP 68 rated Complies with BS EN Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø mm Hexagon Entry Thread Thread Length Protrusion Length Size Qty per Kit (D) (E) (F) Min Max A/F (G) A/C (H) 403P* M20x Replace * to specify colour: R=Red, W=White 14

15 A1/A2 Gland Kit Indoor / Outdoor Cable Gland (KM409 Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED CABLES INDUSTRIAL GLANDS Indoor & outdoor type for Unarmoured cable. Brass indoor and outdoor gland and accessories For circular, unarmoured plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Kit comprises: A1/A2 Gland Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) Suitable for use with all Unarmoured Cables CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN 62444:2013 Service temperature range -20 C to +90 C Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Metric & NPT Nickel Plated versions available Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Qty per Kit (D) (E) (F) Standard Nickel Plated Metric NPT Min Max A/F (G) A/C (H) KM KM409-51V M KM KM409-71V 20SS M KM KM409-52V 20S M KM KM409-53V M KM KM409-55V M KM KM409-56V M KM KM409-57V M KM KM409-58V 50S M KM KM409-59V M KM KM409-60V 63S M KM KM409-61V M KM KM409-62V 75S M KM KM409-63V M KP409-65* KM409-65V M KP409-66* KM409-66V M KP409-67* KM409-67V M Ø NP-04V ½ - 20S ½ NPT NP-08V ¾ ¾ NPT NP-14V NPT NP-20V 1 ¼ ¼ NPT NP-27V 1 ½ ½ NPT NP-31V 2-50S NPT NP-32V NPT NP-37V 2 ½ - 63S ½ NPT NP-44V 3-75S NPT *KP Kits contain only Gland & Locknut **NPT threaded glands are supplied as glands only. 15

16 INDUSTRIAL GLANDS A1/A2 LSOH Gland Kit Indoor / Outdoor Cable Gland (423LSF Series) SUITABLE FOR USE WITH CIRCULAR LSOH UNARMOURED CABLES Indoor & outdoor type for LSOH Unarmoured cable. Brass indoor and outdoor gland and accessories For circular, unarmoured plastic or rubber LSOH sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Kit comprises: A1/A2 Gland Brass Locknut LSOH Shroud (2 per kit up to and including 25mm size) Suitable for use with all LSOH Unarmoured Cables CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN 62444:2013 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Complies with LU Standard for installation in all sub-surface locations LUL APR Product ID 1971 Nickel Plated and standard versions available Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Size Qty per Kit (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) 423LSF LSF-71V 20SS M LSF LSF-52V 20S M LSF LSF-53V M LSF LSF-55V M LSF LSF-56V M LSF LSF-57V M LSF LSF-58V 50S M LSF LSF-59V M LSF LSF-60V 63S M LSF LSF-61V M LSF LSF-62V 75S M LSF LSF-63V M

17 AXT Gland Kit Indoor / Outdoor Cable Gland (423AX Series) SUITABLE FOR USE WITH FLEXIBLE WIRE BRAIDED CABLES (E.G. CY & SY TYPES) INDUSTRIAL GLANDS Indoor & outdoor type for flexible wire braided cable. Brass indoor and outdoor gland and accessories For circular unarmoured, or wire braid or screened, plastic or rubber sheathed cables Superior retention capability Suitable for most climatic conditions, weatherproof and waterproof Kit comprises: AXT Gland 2 x Flat Brass Washers Brass Earth Tag Steel Locknut PVC Shroud (2 per kit) Suitable for use with CY & SY type cables CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -50 C to +200 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length (D) (E) (F) Min Max A/F (G) A/C (H) 423AX-52 20S M AX M AX M

18 INDUSTRIAL GLANDS CW Gland Kit Indoor / Outdoor Cable Gland (KA419 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Indoor & outdoor type for SWA cable. Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: CW Gland Brass Earth Tag Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Metric & NPT versions available Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Overall Ø (B) Thread Protrusion Hexagon Qty Under Armour Armour Entry Thread Length Length per Kit Max Ø (A) Wire Ø (D) Standard Nickel Plated Metric NPT Min Max (E) (F) A/F (G) A/C (H) KA KA419-51V M KA KA419-71V 20SS M KA KA419-52V 20S M KA KA419-53V /1.25 M KA KA419-55V /1.6 M KA KA419-56V /2.0 M KA KA419-57V /2.0 M KA KA419-58V 50S /2.5 M KA KA419-59V /2.5 M KA KA419-61V M KA KA419-63V M KA KA419-64V M KA KA419-65V M Ø 114 KA KA419-66V M Ø KA KA419-67V M Ø NP-10V 1-20S NPT NP-08V ¾ /1.25 ¾ NPT NP-12V /1.6 1 NPT NP-16V 1 ¼ /2.0 1 ¼ NPT NP-25V 2 ½ /2.5 2 ½ NPT NP-26V 2 ½ ½ NPT *NPT threaded glands are supplied as glands only. **Other NPT sizes available upon request. 18

19 CW-B Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KA419-B Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES INDUSTRIAL GLANDS Indoor & outdoor type for SWA cable. 15mm Entry threads to facilitate extra seals / Lock washers Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Suitable for most climatic conditions, weatherproof and waterproof Kit comprises: CW Gland Brass Earth Tag Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) KA419-B M KA419-B91 20SS M KA419-B82 20S M KA419-B /1.25 M KA419-B /1.6 M KA419-B /2.0 M

20 INDUSTRIAL GLANDS CW-B LSOH Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KV419-B Series ) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Indoor & outdoor type for SWA cable. 15mm Entry threads to facilitate extra seals / Lock washers Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Suitable for most climatic conditions, weatherproof and waterproof Kit comprises: CW Gland Brass Earth Tag Brass Locknut LOSH Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) KV419-B M KV419-B91 20SS M KV419-B82 20S M KV419-B /1.25 M KV419-B /1.6 M KV419-B /2.0 M

21 CW LSOH Gland Kit Indoor / Outdoor Cable Gland (422LSF Series) SUITABLE FOR USE WITH ALL LSOH STEEL WIRE ARMOURED CABLES INDUSTRIAL GLANDS Indoor & outdoor type for LSOH SWA cable. Brass indoor & outdoor gland and LSOH accessories For galvanized-steel single-wire armour LSOH plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: CW Gland Brass Earth Tag Brass Locknut LSOH Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 6724, BS 8519, BS 7846, BS 6387, BS 7835 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Complies with LU Standard for installation in all sub-surface locations LUL APR Product ID 1969 Nickel Plated and standard versions available Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Overall Ø (B) Thread Protrusion Hexagon Qty Under Armour Armour Entry Thread Size Length Length per Kit Max Ø (A) Wire Ø (D) Standard Nickel Plated Min Max (E) (F) A/F (G) A/C (H) 422LSF LSF-51V M LSF LSF-71 V 20SS M LSF LSF-52 V 20S M LSF LSF-53 V /1.25 M LSF LSF-55 V /1.6 M LSF LSF-56 V /2.0 M LSF LSF-57 V /2.0 M LSF LSF-58 V 50S /2.5 M LSF LSF-59 V /2.5 M LSF LSF-61 V M LSF LSF-63 V M LSF LSF-64 V M

22 INDUSTRIAL GLANDS CW-AL Gland Kit Indoor / Outdoor Cable Gland (KA422 Series) SUITABLE FOR USE WITH ALL ALUMINIUM WIRE ARMOURED CABLES Aluminium indoor & outdoor gland and accessories For Aluminium wire armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity No Risk of Bi-metallic corrosion when clamping Aluminium Armours Kit comprises: CW-AL Gland Aluminium Earth Tag Aluminium Locknut PCP Shroud (2 per kit up to and including 25mm size) Suitable for use with all Aluminium Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 Constructed using 6082-T6 Alluminium alloy Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) KA S /1.25 M KA /1.25 M KA /1.6 M KA /2.0 M KA /2.0 M KA S /2.5 M KA /2.5 M KA M KA M KA M

23 CW-AL LSOH Gland Kit Indoor / Outdoor Cable Gland (432LSF Series) SUITABLE FOR USE WITH ALL LSOH ALUMINIUM WIRE ARMOURED CABLES INDUSTRIAL GLANDS Indoor & outdoor type for LSOH Aluminium cable. Aluminium indoor & outdoor gland and LSOH accessories For Aluminium wire armour LSOH plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity No Risk of Bi-metallic corrosion when clamping Aluminium Armours Kit comprises: CW-AL Gland Aluminium Earth Tag Aluminium Locknut LSOH Shroud (2 per kit up to and including 25mm size) Suitable for use with all Aluminium Wire Armoured Cables inc: BS 6724, BS 7835 Constructed using 6082-T6 Alluminium alloy Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) 432LSF-52 20S M LSF /1.25 M LSF /1.6 M LSF /2.0 M LSF /2.0 M LSF-58 50S /2.5 M LSF /2.5 M LSF M LSF M

24 INDUSTRIAL GLANDS CX Gland Kit Indoor / Outdoor Cable Gland (KA414 Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES Indoor & outdoor type for Wire Braid Armour cable Brass indoor & outdoor gland and accessories For Wire braid armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: CX Gland Brass Earth Tag Brass Locknut PCP Shroud (2 per kit up to and including 25mm size) Suitable for use with all Wire Braid Armoured Cables CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Braid Max Ø (A) Overall Ø (B) Hexagon Braid Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) KA * / 0.3 M KA mini* / 0.3 M KA / 0.3 M KA SS / 0.3 M KA S / 0.3 M KA / 0.3 M KA / 0.45 M KA / 0.45 M KA / 0.45 M KA / 0.45 M KA / 0.45 M KA / 0.45 M KA / 0.45 M KA / 0.45 M Ø 114 * For use with miniature braided cables. These kits do not include a shroud 24

25 CX-B Gland Kit (Long entry thread) Indoor / Outdoor Cable Gland (KA414-B Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES INDUSTRIAL GLANDS Indoor & outdoor type for Wire Braid Armour cable. 15mm Entry threads to facilitate extra seals / Lock washers Brass indoor & outdoor gland and accessories For Wire braid armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: CX Gland Brass Earth Tag Brass Locknut PCP Shroud (2 per kit up to and including 25mm size) Suitable for use with all Wire Braid Armoured Cables CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Braid Max Ø (A) Overall Ø (B) Hexagon Braid Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) KA414-B / 0.3 M KA414-B91 20SS / 0.3 M KA414-B82 20S / 0.3 M KA414-B / 0.3 M KA414-B / 0.45 M KA414-B / 0.45 M

26 INDUSTRIAL GLANDS E1W Gland Kit Outdoor Wet Area Cable Gland (KAA413 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour, plastic or rubber sheathed cables Outer seal grips sheath of cable Inner seal grips bedding layer of cable Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: E1W Gland Brass Earth Tag Brass Locknut PVC Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Metric and NPT versions available. Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Size Overall Ø (B) Thread Protrusion Hexagon Qty Max Ø (A) Armour Entry Thread Length Length per Kit Wire Ø (D) Standard Nickel Plated Metric NPT Min Max Min Max (E) (F) A/F (G) A/C (H) KAA KAA413-51V M KAA KAA413-71V 20SS M KAA KAA413-52V 20S /1.25 M KAA KAA413-53V /1.25 M KAA KAA413-55V /1.6 M KAA KAA413-56V /2.0 M KAA KAA413-57V /2.0 M KAA KAA413-58V 50S /2.5 M KAA KAA413-59V /2.5 M KAA KAA413-60V 63s M KAA KAA413-61V M KAA KAA413-62V 75s M KAA KAA413-63V M KAA KAA413-64V M KAA KAA413-65V M Ø NP-03V ½ ½ NPT NP-04V ½ - 20S /1.25 ½ NPT NP-08V ¾ /1.25 ¾ NPT NP-14V /1.6 1 NPT NP-20V 1 ¼ /2.0 1 ¼ NPT NP-27V 1 ½ /2.0 1 ½ NPT NP-31V 2-50S /2.5 2 NPT NP-32V /2.5 2 NPT NP-38V 2 ½ ½ NPT NP-44V 3-75S NPT NP-45V NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 26

27 E1W Gland Kit Outdoor Wet Area Cable Gland (KA413 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES INDUSTRIAL GLANDS Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables Outer seal grips sheath of cable Inner seal grips bedding layer of cable Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: E1W Gland Brass Earth Tag Brass Locknut PCP Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Metric & NPT versions available. Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Size Overall Ø (B) Thread Protrusion Hexagon Qty Max Ø (A) Armour Entry Thread Length Length per Kit Wire Ø (D) Standard Nickel Plated Metric NPT Min Max Min Max (E) (F) A/F (G) A/C (H) KA KA413-51V M KA KA413-71V 20SS M KA KA413-52V 20S /1.25 M KA KA413-53V /1.25 M KA KA413-55V /1.6 M KA KA413-56V /2.0 M KA KA413-57V /2.0 M KA KA413-58V 50S /2.5 M KA KA413-59V /2.5 M KA KA413-60V 63s M KA KA413-61V M KA KA413-62V 75s M KA KA413-63V M KA KA413-64V M KA KA413-65V M Ø NP-03V ½ ½ NPT NP-04V ½ - 20S /1.25 ½ NPT NP-08V ¾ /1.25 ¾ NPT NP-14V /1.6 1 NPT NP-20V 1 ¼ /2.0 1 ¼ NPT NP-27V 1 ½ /2.0 1 ½ NPT NP-31V 2-50S /2.5 2 NPT NP-32V /2.5 2 NPT NP-38V 2 ½ ½ NPT NP-44V 3-75S NPT NP-45V NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 27

28 INDUSTRIAL GLANDS E1W LSOH Gland Kit Outdoor Wet Area Cable Gland (421LSF Series) SUITABLE FOR USE WITH ALL LSOH STEEL WIRE ARMOURED CABLES Brass indoor & outdoor gland and accessories For galvanized-steel single-wire armour plastic or rubber sheathed cables Outer seal grips sheath of cable Inner seal grips bedding layer of cable Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: E1W Gland Brass Earth Tag Brass Locknut LSOH Shroud (2 per kit up to and including 25mm size) Suitable for use with all Steel Wire Armoured Cables inc: BS 6724, BS 8519, BS 7846, BS 6387, BS 7835 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Complies with LU Standard for installation in all sub-surface locations LUL APR Product ID 1970 Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Overall Ø (B) Hexagon Ø (A) Armour Entry Thread Thread Length Protrusion Length Size Qty per Kit Wire Ø (D) (E) (F) Min Max Min Max A/F (G) A/C (H) 421LSF-71 20SS M LSF-52 20S /1.25 M LSF /1.25 M LSF /1.6 M LSF /2.0 M LSF /2.0 M LSF-58 50S /2.5 M LSF /2.5 M LSF-60 63s M LSF M LSF-62 75s M LSF M

29 CW Integral Earth Gland Kit Indoor / Outdoor Cable Gland (419CE Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES WITH HIGH FAULT CURRENT INDUSTRIAL GLANDS Indoor & outdoor type for SWA cable. Brass indoor & outdoor gland with Earth bonding Connection For galvanized-steel single-wire armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity Kit comprises: CW Integral Earth Gland Brass Locknut Suitable for use with all Steel Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 CuZn39Pb3 brass alloy used for guaranteed strength and performance Complies with BS EN & BS : 1989 Integral earth connection complies with GDCD 190 Category A - (43.3kA for 1 second) Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Integral Earth connection made using an M10 or M12 fixing Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) 419CE-52 20S /1.25 M CE /1.25 M CE /1.6 M CE /2.0 M CE /2.0 M CE /2.5 M CE M CE M CE M CE M Ø CE M Ø CE M Ø

30 INDUSTRIAL GLANDS CW-AL Integral Earth Gland Kit Indoor / Outdoor Cable Gland (454CE Series) SUITABLE FOR USE WITH ALUMINIUM WIRE ARMOURED CABLES WITH HIGH FAULT CURRENT Aluminium indoor & outdoor gland and accessories For Aluminium-wire armour plastic or rubber sheathed cables Suitable for most climatic conditions, weatherproof and waterproof Three part armour lock with separate armour locking ring, ideal for checking electrical continuity No Risk of Bi-metallic corrosion when clamping Aluminium Armours Kit comprises: CW-A integral earth Gland Aluminium Locknut Suitable for use with all Aluminium Wire Armoured Cables inc: BS 5467, BS 6622, BS 5308 Constructed using 6082-T6 Alluminium alloy Complies with BS EN & BS : 1989 Integral earth connection complies with GDCD 190 Category A - (43.3kA for 1 second) Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Integral Earth connection made using an M10 or M12 fixing. Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Under Armour Max Ø (A) Overall Ø (B) Hexagon Armour Entry Thread Thread Length Protrusion Length Wire Ø (D) (E) (F) Min Max A/F (G) A/C (H) 454CE-52 20S /1.25 M CE /1.25 M CE /1.6 M CE /2.0 M CE /2.0 M CE /2.5 M CE M CE M

31 CW-Dual Screen Gland Kit Concentric Bonding Cable Gland (422DA Series) SUITABLE FOR USE WITH SINGLE CORE CONCENTRIC BONDING CABLES WITH DUAL LAYER SCREENS Concentric Bonding Cable gland Brass Gland and accessories For Dual layer copper wire Screened Concentric Bonding Cables Suitable for most climatic conditions, weatherproof and waterproof Tandomized armour ring & body arrangement for compact termination of 2 layers of Copper screen wires Secondary seal & shroud for topside of the steel structure Kit comprises: Dual Screen CW Gland Nylon Sealing Washer Top seal assembly LSOH Shroud for Top Seal assembly INDUSTRIAL GLANDS Suitable for use with all Concentric dual layer copper wire screened bonding cables Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface Service temperature range -20 C to +90 C Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Size Qty per Kit Conductor Overall Ø (B) Hexagon Insulation Ø (A) Screen Entry Thread Protrusion Protrusion Wire Ø Thread Length Length (M) Length (N) Min Max Min Max A/F (G) A/C (H) 422DA /1.3 M DA-91 50ss /2.2 M DA-92 50s /2.1 M DA /2.1 M DA M DA M

32 HAZARDOUS GLANDS Introduction to Hazardous Areas Explosive Atmospheres Explosive Atmospheres are defined as a combination of flammable gases, vapours or solids ( dusts & fibres ) mixed with Air. When combined with a source of ignition the combination will combust burning all of the available flammable mixture. Hazardous Locations In order to protect personal and equipment from potential explosions the principle of area classification is used - this involves risk assessing the plant area and defining areas according to the type of flammable material and the probability of its release to create an explosive atmosphere. Area classification Under the IECEx / Atex systems a plant will be divided into non-hazardous and hazardous areas. The hazardous areas are then sub-divided into Zones. Combustible Gases & Vapours : Zone 0 : Explosive Atmosphere permanently present, or present for very long periods. Zone 1 : Explosive Atmospheres may be present as a result of normal operation Zone 2 : Explosive Atmospheres not present as a result of normal operations and if they do occur they are only present for a very short duration. Combustible Dusts & Fibres: Zones 20, 21 and 22 are the dust & fibre equivalents of Zones 0,1 & 2. Protection Methods - (applicable to Bicon glands) Ex Ia & Ex Ib -Intrinsically safe equipment designed in such a way that the energy of any spark is lower than what is required to ignite a flammable mixture. Ia is designed to a higher integrity and can be used in Zone 0 locations whereas Ib is only suitable for Zone 1 & 2 locations. Ex d Flameproof equipment is designed in such a way that it can contain / control an ignited flammable mixture and prevent it from igniting any flammable mixture that may be outside the equipment. This protection method can be used in Zones 1 & 2. Ex e Increased safety equipment is designed using components that cannot create arcs and sparks i.e. result in ignition these enclosures can be made from thinner section materials but are required to be sealed to a minimum ingress protection level of IP54. This protection method can be used in Zones 1 & 2. Ex p pressurized equipment that is constantly pressurized such that flammable mixtures are continuously expelled from the equipment. This protection method can be used in zones 1& 2. Ex na - Similar to Exe in that equipment should not create arcs and sparks but not to the same stringent levels. This protection method can only be used in Zone 2. Ex nr - Restricted breathing equipment is fitted with tightly fitting seals which help prevent the ingress of explosive mixtures and thus prevents them from reaching hot components. This protection method can only be used in Zone 2. 32

33 Gas Groups Explosive gases are split into 2 groups: Group 1: Underground mining related gases i.e Firedamp / Methane Group 2: Gases present in other locations. Exd and Exi Equipment used with Group 2 gases are further sub divided into 3 categories IIA, IIB & IIC appropriate to the gas / vapour sub-division. Gas / Vapour Hydrogen Acetylene Carbon Di-Sulphide Hydrogen Sulphide Ethylene Sulphide Ethylene Propane Butane Equipment Sub Group Allowed IIC IIC IIC IIC, IIB IIC, IIB IIC, IIB IIC, IIB, IIA IIC, IIB, IIA Surface Temperature classification Temperature Class Max surface Temp ºC T1 450 T2 300 T3 200 T4 135 T5 100 T6 85 Temperature Ratings / Classes for Cable Glands Cable glands are not allocated a T class because they are designed as a component part of a piece of equipment and in themselves do not produce heat; therefore it is impossible to assess any heating effects. However glands are allocated a service temperature, which is the temperature range to which a gland may be subjected to in service (if not specified in the certification report this is assumed to be -20ºC / +40ºC and it is the responsibility of the user, in accordance with the installation codes of practice, to select an appropriate gland. In some cases it may be possible for a gland manufacturer to state that a gland is suitable for a specific T class application, i.e. where the glands specified service temperature significantly exceeds the limiting temperature of the specified T class, but the gland will not be marked with any T rating. In most cases the above assessment is best left to the user, since T classes are allocated on the basis of a maximum possible external surface temperature, whilst in service the gland may see greater internal temperatures, or vastly reduced temperatures, due to factors like positioning, the external ambient and the geometry of the enclosure to which they are fitted. 33

34 HAZARDOUS GLANDS BS EN : Selection of cable glands The cable entry system shall comply with one of the following: a) Cable glands sealed with setting compound (barrier cable glands) in compliance with IEC and certified as equipment; b) Cables and glands meeting all of the following: - cable glands comply with IEC and are certified as equipment - cables used comply with 9.3.2(a)* - the connected cable is at least 3 m in length; c) indirect cable entry using combination of flameproof enclosure with a bushing and increased safety terminal box; Where there is a likelihood that propagation of flames may occur through the interstices between individual cores of a cable, this shall also be considered. NOTE 1: The minimum length of cable is to minimize the potential for flame transmission through the cable (see also Annex E); * BS EN : Cables for fixed installations Cables used for fixed installations in hazardous areas shall be appropriate for the ambient conditions in service. Cables shall be: a) sheathed with thermoplastic, thermosetting, or elastomeric material. They shall be circular and compact. Any bedding or sheath shall be extruded. Fillers, if any, shall be non-hygroscopic; Where there is a likelihood that gas or vapour migration may occur through the interstices between individual cores of a cable, and the cable leads to a non-hazardous area or between different zones, then the construction and application of the cable shall be taken into account. Appropriate control measures to mitigate this condition shall be considered (see Annex E). BS EN :2014 National annex.4 UK committee concerns 2. The UK committee have not seen documented evidence of any tests carried out to justify either the removal of the 2008 selection chart or its replacement by the new selection procedure. 3. Verbal descriptions of recent tests seem to suggest that the tests only relate to ignitions through the cable. The original research project highlighted that severe thermal damage can be inflicted on the core insulation and bedding by the heat generated by multiple explosions within the enclosure. This could result in subsequent catastrophic failure of the cable leading to ignition of the surrounding atmosphere. NOTE 1: The new edition seeks to clarify the requirement for the cable to be at least 3 m in length by referencing the new Annex E of the standard. Annex E is titled `Restrictive breathing test for cables and prescribes pressure drop tests with the cable connected to an enclosure. However, as this annex is informative, it is not clear whether cables will require testing to avoid the need for a barrier gland. The UK committee is of the opinion that such testing is not reasonably practicable. BS EN :2014 National annex.5 Recommendation by the UK committee for users of this standard and notice of future intent Given the serious concerns expressed by the UK committee in relation to IEC :2013 (Edition 5), clause b) throughout the whole revision process, they intend to submit a proposal to IEC to amend Edition 5. Until such time as the situation is resolved, the UK committee recommend that users continue to consult the selection chart, reproduced as Figure 1 in this Annex, to complement the standard. 34

35 BS EN :2008 Selection of Cable Glands (BS EN :2014 UK national Annex Figure 1) Where a cable is sheathed with thermoplastic, thermosetting, or elastomeric material, is circular, substantially compact, has extruded bedding and fillers, if any, are non hygroscopic, a flameproof cable gland, in compliance with IEC , may be utilized, providing this incorporates a sealing ring and is selected in accordance with Figure 1. START HAZARDOUS GLANDS Yes Does this enclosure contain an internal source of ignition? a No Apply D) or E) Yes Yes Does the hazardous gas require IIC apparatus? Yes Is the volume b of the enclosure greater than 2 dm 3? No Is the area of installation zone 1? No No Use a suitable flameproof cable entry device with a sealing ring IEC 2696/02 a Internal sources of ignition include sparks or equipment temperatures occurring in normal operation which can cause ignition. An enclosure containing terminals only or an indirect entry enclosure (see ) is considered not to constitute an internal source of ignition. 35

36 HAZARDOUS GLAND SELECTION CHART METRIC GLANDS TO ATEX & IECEX STANDARDS HAZARDOUS GLANDS Ex e Equipment Type? Ex d Cable Construction? Fully Filled Yes Ignition Source? Armoured Cable? Not Fully Filled Yes IIC? No No Yes Zone 1? No Yes Barrier Type Yes Volume >2 litres? No Fameproof Type Armoured Cable? Armoured Cable? No Armour Type? Yes No Yes SWA Braid Armour Type? SWA Armour Type? Braid No Exe Nylon E1WF Tape E1XF SWA Braid E1WF Tape E1XF A2EX E1W-XL E1W-XL E1W-XL E1W-XL A2EX A2EXP Excel Plus Excel Plus Excel Plus Barr-W Barr-X Barr-A Excel Plus Excel Plus Excel Plus A2EXP 36

37 HAZARDOUS AREA GLAND CONTENTS Location Protection Armour Gland Page Exe Un-Armoured Nylon Exe ATEX Gland & Nut 403AT 38 A2EX Gland Exe Exd IIC (+ Nickel Plated Version) 494AB (V) 39 A2EX Gland Exe Exd IIC - NPT (+ Nickel Plated Version) 494NE (V) 40 Un-Armoured A2EX Gland Kit Exe Exd IIC (+ Nickel Plated Version) KM494 (V) 41 A2EX Gland Kit Exe Exd IIC - LOSH Shroud (+ Nickel Plated Version) KCH494 (V) 42 A2EXPlus Gland Exe Exd IIC (+ Nickel Plated Version) 495AB (V) 43 A2EXPlus Gland Exe Exd IIC - NPT (+ Nickel Plated Version) 495NE (V) 44 A2EXPlus Gland Kit Exe Exd IIC (+ Nickel Plated Version) KM495 (V) 45 HAZARDOUS GLANDS E1WF Gland Exe Exd IIC (+ Nickel Plated Version) 472AA (V) 46 E1WF Gland Exe Exd IIC - NPT (+ Nickel Plated Version) 472NP (V) 47 SWA / AWA E1WF Gland Kit Exe Exd IIC (+ Nickel Plated Version) KCA472 (V) 48 E1WF Gland Kit Exe Exd IIC - PCP Shroud (+ Nickel Plated Version) KA472 (V) 49 Exd + Exe E1WF Aluminium Gland Exe Exd IIC 455AA 50 Hazardous Areas E1WF Aluminium Gland Kit Exe Exd IIC KCA E1XF Gland Exe Exd IIC (+ Nickel Plated Version) 473AA (V) 52 Braid E1XF Gland Exe Exd IIC - NPT (+ Nickel Plated Version) 473NP (V) 53 E1XF Gland Kit Exe Exd IIC (+ Nickel Plated Version) KCA473 (V) 54 E1XF Gland Kit Exe Exd IIC - PCP Shroud (+ Nickel Plated Version) KA473 (V) 55 E1WXL Gland Exe Exd IIC (+ Nickel Plated Version) 474SW (V) 56 SWA + Braid + Lead E1WXL Gland Exe Exd IIC - NPT (+ Nickel Plated Version) 474NP (V) 57 E1WXL Gland Kit Exe Exd IIC (+ Nickel Plated Version) KA474 (V) 58 Excel Plus Gland Exe Exd IIC (+ Nickel Plated Version) 493AB (V) 59 SWA + Braid + Tape Excel Plus Gland Exe Exd IIC - NPT (+ Nickel Plated Version) Excel Plus Gland Kit Exe Exd IIC (+ Nickel Plated Version) 493NE (V) 60 KA493 (V) 61 Un-Armoured Barr-A Gland Exd IIC (+ Nickel Plated Version) 424TA (V) 62 Exd Barrier SWA Barr-W Gland Exd IIC (+ Nickel Plated Version) 424TW (V) 63 Braid Barr-X Gland Exd IIC (+ Nickel Plated Version) 424TX (V) 64 SWA + Lead Barr-PB Gland Exd IIC (+ Nickel Plated Version) 424TP (V) 65 37

38 HAZARDOUS GLANDS Nylon indoor and outdoor cable gland for use in hazardous locations. Suitable for use with all Unarmoured circular cables. Suitable for most climatic conditions - weather proof & waterproof Supplied with nylon locknut Nylon Ex e Cable Gland (403AT Series) Achieves IP66 and IP68 seal onto cable and to enclosure with suitable sealing washer or thread sealant Certified ΙΙ 2GD, Ex e ΙΙ under ATEX directive 94/9/EC. Atex Compliance Standards: EN , EN , EN , EN Certificate number LCIE07ATEX6082X. Service temperature range 35 C to +95 C. SUITABLE FOR USE WITH CIRCULAR UNARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Kit comprises: Nylon Gland Nylon lock nut Gland Reference Cable Dimensions mm Gland Dimensions mm Size Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length (D) (E) (F) Min Max A/F (G) A/C (H) 403AT M16x AT-52 20S 7 12 M20x AT M20x AT M25x AT M32x AT M40x AT M50x AT M63x

39 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EX Ex d IIC / Ex e II Cable Gland (494AB Series) Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Gland Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Size (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) 494AB AB-51V M AB AB-71V 20SS M AB AB-52V 20S M AB AB-53V M AB AB-55V M AB AB-56V M AB AB-57V M AB AB-59V M AB AB-61V M AB AB-62V 75S M AB AB-63V M Sizes 32mm and above shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. 39

40 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EX(NPT) Ex d IIC / Ex e II Cable Gland (494NE Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Gland Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Size (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) 494NE NE-03V ½ ½ NPT NE NE-04V ½ - 20S ½ NPT NE NE-05V ½ ½ NPT NE NE-08V ¾ ¾ NPT NE NE-10V ¾ ¾ NPT NE NE-14V NPT NE NE-15V NPT NE NE-20V 1¼ ¼ NPT NE NE-21V 1¼ ¼ NPT NE NE-27V 1 ½ ½ NPT NE NE-32V NPT NE NE-38V 2½ ½ NPT NE NE-44V 3-75S NPT NE NE-45V NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. Sizes 32 and above shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. 40

41 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EX Ex d IIC / Ex e II Cable Gland kit (PVC) (KM494 Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Kit comprises: A2EX Gland Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) Hexagon Qty per mm Entry Thread Thread Length Protrusion Length Size Kit (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) KM KM494-51V M KM KM494-71V 20SS M KM KM494-52V 20S M KM KM494-53V M KM KM494-55V M KM KM494-56V M KM KM494-57V M KM KM494-59V M KM KM494-61V M KM KM494-62V 75S M KM KM494-63V M Sizes 32 and above shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. 41

42 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EX Ex d IIC / Ex e II Cable Gland kit (LSOH) (KCH494 Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Sizes 32 and above shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. Kit comprises: A2EX Gland Brass Locknut Nylon Sealing Washer LOSH Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) Hexagon Qty per mm Entry Thread Thread Length Protrusion Length Size Kit (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) KCH KCH494-51V M KCH KCH494-71V 20SS M KCH KCH494-52V 20S M KCH KCH494-53V M KCH KCH494-55V M KCH KCH494-56V M KCH KCH494-57V M KCH KCH494-59V M KCH KCH494-61V M KCH KCH494-62V 75S M KCH KCH494-63V M

43 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EXP Ex d IIC / Ex e II Dual Seal Cable Gland (495AB Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Gland Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Size (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) 495AB AB-51V M AB AB-71V 20SS M AB AB-52V 20S M AB AB-53V M AB AB-55V M AB AB-56V M AB AB-57V M AB AB-59V M AB AB-61V M AB AB-62V 75S M AB AB-63V M Sizes 75s and 75 shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. 43

44 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EXP (NPT) Ex d IIC / Ex e II Dual Seal Cable Gland (495NE Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Gland Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) mm Hexagon Entry Thread Thread Length Protrusion Length Size (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) 495NE NE-03V ½ ½ NPT NE NE-04V ½ - 20S ½ NPT NE NE-05V ½ ½ NPT NE NE-08V ¾ ¾ NPT NE NE-10V ¾ ¾ NPT NE NE-14V NPT NE NE-15V NPT NE NE-20V 1¼ ¼ NPT NE NE-21V 1¼ ¼ NPT NE NE-27V 1½ ½ NPT NE NE-32V NPT NE NE-38V 2½ ½ NPT NE NE-44V 3-75S NPT NE NE-45V NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. Sizes 75s and 75 shall only be used for fixed installations. In addition the user / installer should ensure that the cables are adequately clamped. 44

45 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular Unarmoured cables with extruded oversheath Fitted with silicone rubber low smoke, zero halogen seal Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant Suitable for most climatic conditions weatherproof, waterproof and deluge proof Standard and Nickel plated versions available Full Installation Instructions supplied A2EXP Ex d IIC / Ex e II Dual Seal Cable Gland Kit (KM495 Series) SUITABLE FOR USE WITH CIRCULAR UNARMOURED & BRAIDED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira99ATEX1086X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 50 C to +200 C May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS UL Classified in accordance with IEC , and for use in hazardous locations UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada Kit comprises: A2EX Gland Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Cable Diameter Ø (B) Hexagon Qty per mm Entry Thread Thread Length Protrusion Length Size Kit (D) (E) (F) Standard Nickel Plated Min Max A/F (G) A/C (H) KM KM495-51V M KM KM495-71V 20SS M KM KM495-52V 20S M KM KM495-53V M KM KM495-55V M KM KM495-56V M KM KM495-57V M KM KM495-59V M KM KM495-61V M KM KM495-62V 75S M KM KM495-63V M

46 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied E1WF Ex d IIC / Ex e II Cable Gland (472AA Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equipment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Thread Protrusion Hexagon Armour Entry Thread Size Length Length Wire Ø (D) Standard Nickel Plated Min Max Min Max (E) (F) A/F (G) A/C (H) 472AA AA-51V M AA AA-71V 20SS M AA AA-52V 20S / 1.25 M AA AA-53V / 1.25 M AA AA-55V / 1.6 M AA AA-56V / 2.0 M AA AA-57V / 2.0 M AA AA-58V 50S / 2.5 M AA AA-59V / 2.5 M AA AA-60V 63S M AA AA-61V M AA AA-62V 75S M AA AA-63V M AA AA-64V M85 x

47 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1WF(NPT) Ex d IIC / Ex e II Cable Gland (472NP Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equipment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment HAZARDOUS GLANDS Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Thread Protrusion Hexagon Armour Entry Thread Size Length Length Wire Ø (D) Standard Nickel Plated Min Max Min Max (E) (F) A/F (G) A/C (H) 472NP NP-03V ½ ½ NPT NP NP-04V ½ - 20S / 1.25 ½ NPT NP NP-07V ¾ - 20S / 1.25 ¾ NPT NP NP-05V ½ / 1.25 ½ NPT NP NP-08V ¾ / 1.25 ¾ NPT NP NP-10V ¾ / 1.6 ¾ NPT NP NP-14V / NPT NP NP-15V / NPT NP NP-20V 1¼ / 2.0 1¼ NPT NP NP-21V 1¼ / 2.0 1¼ NPT NP NP-27V 1½ / 2.0 1½ NPT NP NP-28V 1½ - 50S / 2.5 1½ NPT NP NP-31V 2" - 50S / NPT NP NP-32V 2" / NPT NP NP-33V 2" - 63S NPT NP NP-38V 2½ ½ NPT NP NP-39V 2½ - 75S ½ NPT NP NP-45V 3" NPT NP NP-47V 3" NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 47

48 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied E1WF Ex d IIC / Ex e II Cable Gland Kit (PVC) (KCA472 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equipment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1WF Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Protrusion Hexagon Qty per Armour Entry Thread Thread Size Length Kit Wire Ø (D) Length (E) Standard Nickel Plated Min Max Min Max (F) A/F (G) A/C (H) KCA KCA472-51V M KCA KCA472-71V 20SS M KCA KCA472-52V 20S / 1.25 M KCA KCA472-53V / 1.25 M KCA KCA472-55V / 1.6 M KCA KCA472-56V / 2.0 M KCA KCA472-57V / 2.0 M KCA KCA472-58V 50S / 2.5 M KCA KCA472-59V / 2.5 M KCA KCA472-60V 63S M KCA KCA472-61V M KCA KCA472-62V 75S M KCA KCA472-63V M KCA KCA472-64V M85 x

49 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied E1WF Ex d IIC / Ex e II Cable Gland Kit (PCP) (KA472 Series) SUITABLE FOR USE WITH ALL STEEL WIRE ARMOURED CABLES Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1WF Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PCP Shroud (2 per kit up to and including 25mm size) HAZARDOUS GLANDS Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Protrusion Hexagon Qty per Armour Entry Thread Thread Size Length Kit Wire Ø (D) Length (E) Standard Nickel Plated Min Max Min Max (F) A/F (G) A/C (H) KA KA472-51V M KA KA472-71V 20SS M KA KA472-52V 20S / 1.25 M KA KA472-53V / 1.25 M KA KA472-55V / 1.6 M KA KA472-56V / 2.0 M KA KA472-57V / 2.0 M KA KA472-58V 50S / 2.5 M KA KA472-59V / 2.5 M KA KA472-60V 63S M KA KA472-61V M KA KA472-62V 75S M KA KA472-63V M KA KA472-64V M85 x

50 HAZARDOUS GLANDS Aluminium indoor and outdoor cable gland for use in hazardous areas Suitable for circular, aluminium wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1WF-Al Ex d IIC / Ex e II Cable Gland (455AA Series) SUITABLE FOR USE WITH ALL ALUMINIUM WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Gland Reference Cable Dimensions mm Gland Dimensions mm Design Under Armour Ø (A) Overall Ø (B) Thread Protrusion Hexagon Reference Armour Thread Length Size Length Length Wire Ø (D) Standard Min Max Min Max (E) (F) A/F (G) A/C (H) 455AA M AA-71 20SS M AA-52 20S / 1.25 M AA / 1.25 M AA / 1.6 M AA / 2.0 M AA / 2.0 M AA-58 50S / 2.5 M AA / 2.5 M AA-60 63S M AA M AA-62 75S M AA M AA M85 x

51 Aluminium indoor and outdoor cable gland for use in hazardous areas Suitable for circular, aluminium wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1WF-Al Ex d IIC / Ex e II Cable Gland Kit (KCA455 Series) SUITABLE FOR USE WITH ALL ALUMINIUM WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1WF-Al Gland Aluminium Earth Tag Aluminium Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) HAZARDOUS GLANDS Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Design Under Armour Ø (A) Overall Ø (B) Protrusion Hexagon Reference Qty per Armour Entry Thread Size Length Kit Wire Ø Thread (D) Length (E) Standard Min Max Min Max (F) A/F (G) A/C (H) KCA M KCA SS M KCA S / 1.25 M KCA / 1.25 M KCA / 1.6 M KCA / 2.0 M KCA / 2.0 M KCA S / 2.5 M KCA / 2.5 M KCA S M KCA M KCA S M KCA M KCA M85 x

52 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1XF Ex d IIC / Ex e II Cable Gland (473AA Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Braid Entry Thread Protrusion Hexagon Size Armour Thread Length Length Standard Nickel Plated Min Max Min Max Wire Ø (D) (E) (F) A/F (G) A/C (H) 473AA AA-51V /0.3 M AA AA-71V 20SS /0.3 M AA AA-52V 20S /0.3 M AA AA-53V /0.3 M AA AA-55V /0.45 M AA AA-56V /0.45 M AA AA-57V /0.45 M AA AA-58V 50S /0.45 M AA AA-59V /0.45 M AA AA-60V 63S /0.45 M AA AA-61V /0.45 M AA AA-62V 75S /0.45 M AA AA-63V /0.45 M AA AA-64V /0.45 M85 x

53 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1XF(NPT) Ex d IIC / Ex e II Cable Gland (473NP Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment HAZARDOUS GLANDS Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Braid Entry Thread Protrusion Hexagon Size Armour Thread Length Length Standard Nickel Plated Min Max Min Max Wire Ø (D) (E) (F) A/F (G) A/C (H) 473NP NP-03V ½ /0.3 ½ NPT NP NP-04V ½ - 20S /0.3 ½ NPT NP NP-07V ¾ - 20S /0.3 ¾ NPT NP NP-05V ½ /0.3 ½ NPT NP NP-08V ¾ /0.3 ¾ NPT NP NP-10V ¾ /0.3 ¾ NPT NP NP-14V /0.3 1 NPT NP NP-15V / NPT NP NP-20V 1¼ /0.45 1¼ NPT NP NP-21V 1¼ /0.45 1¼ NPT NP NP-27V 1 ½ /0.45 1½ NPT NP NP-28V 1 ½ - 50S /0.45 1½ NPT NP NP-32V 2" / NPT NP NP-33V 2" - 63S / NPT NP NP-38V 2½ /0.45 2½ NPT NP NP-44V 3"- 75S / NPT NP NP-45V 3" / NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 53

54 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1XF Ex d IIC / Ex e II Cable Gland Kit (PVC) (KCA473 Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1XF Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Braid Entry Thread Protrusion Hexagon Qty per Size Armour Thread Length Length Kit Standard Nickel Plated Min Max Min Max Wire Ø (D) (E) (F) A/F (G) A/C (H) KCA KCA473-51V /0.3 M KCA KCA473-71V 20SS /0.3 M KCA KCA473-52V 20S /0.3 M KCA KCA473-53V /0.3 M KCA KCA473-55V /0.45 M KCA KCA473-56V /0.45 M KCA KCA473-57V /0.45 M KCA KCA473-58V 50S /0.45 M KCA KCA473-59V /0.45 M KCA KCA473-60V 63S /0.45 M KCA KCA473-61V /0.45 M KCA KCA473-62V 75S /0.45 M KCA KCA473-63V /0.45 M

55 Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1XF Ex d IIC / Ex e II Cable Gland Kit (PCP) (KA473 Series) SUITABLE FOR USE WITH ALL BRAID WIRE ARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1XF Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PCP Shroud (2 per kit up to and including 25mm size) HAZARDOUS GLANDS Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Braid Entry Thread Protrusion Hexagon Qty per Size Armour Thread Length Length Kit Standard Nickel Plated Min Max Min Max Wire Ø (D) (E) (F) A/F (G) A/C (H) KA KA473-51V /0.3 M KA KA473-71V 20SS /0.3 M KA KA473-52V 20S /0.3 M KA KA473-53V /0.3 M KA KA473-55V /0.45 M KA KA473-56V /0.45 M KA KA473-57V /0.45 M KA KA473-58V 50S /0.45 M KA KA473-59V /0.45 M KA KA473-60V 63S /0.45 M KA KA473-61V /0.45 M KA KA473-62V 75S /0.45 M KA KA473-63V /0.45 M

56 HAZARDOUS GLANDS UNIVERSAL GLAND SUITABLE FOR USE WITH STEEL WIRE ARMOUR, BRAID WIRE ARMOURED AND LEAD SHEATHED CABLES Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Continuity Connection for Lead Inner sheathed cables Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3093X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1W-XL Ex d IIC / Ex e II Cable Gland (474SW Series) May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Braid Lead Sheath Ø Entry Thread Protrusion Hexagon Armour Size Armour Thread Length Length Wire Ø Standard Nickel Plated Min Max Min Max Wire Ø Min Max (D) (E) (F) A/F (G) A/C (H) 474SW SW-71V 20SS / M20 x SW SW-52V 20S / / M20 x SW SW-53V / / M20 x SW SW-55V / / M25 x SW SW-56V / / M32 x SW SW-57V / / M40 x SW SW-58V 50S / / M50 x SW SW-59V / / M50 x SW SW-60V 63S / M63 x SW SW-61V / M63 x SW SW-62V 75S / M75 x SW SW-63V / M75 x SW SW-64V / M85 x

57 UNIVERSAL GLAND SUITABLE FOR USE WITH STEEL WIRE ARMOUR, BRAID WIRE ARMOURED AND LEAD SHEATHED CABLES Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Continuity Connection for Lead Inner sheathed cables Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3093X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1W-XL (NPT) Ex d IIC / Ex e II Cable Glands (474NP Series) May be used in: Zones 1 & 2 with Ex e II equipment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment HAZARDOUS GLANDS Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Overall Ø (B) Braid Lead Sheath Ø Entry Thread Protrusion Hexagon Ø (A) Armour Size Armour Thread Length Length Wire Ø Standard Nickel Plated Min Max Min Max Wire Ø Min Max (D) (E) (F) A/F (G) A/C (H) 474NP NP-03V ½ - 20SS / ½ NPT NP NP-04V ½ - 20S / / ½ NPT NP NP-07V ¾ - 20S / / ¾ NPT NP NP-05V ½ / / ½ NPT NP NP-08V ¾ / / ¾ NPT NP NP-10V ¾ / / ¾ NPT NP NP-14V / / NPT NP NP-15V / / NPT NP NP-20V 1¼ / / ¼ NPT NP NP-21V 1¼ / / ¼ NPT NP NP-27V 1½ / / ½ NPT NP NP-28V 1½ - 50S / / ½ NPT NP NP-31V 2-50S / / NPT NP NP-32V / / NPT NP NP-33V 2-63S / NPT NP NP-38V 2½ / ½ NPT NP NP-39V 2½ - 75S / ½ NPT NP NP-45V / NPT NP NP-47V / NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 57

58 HAZARDOUS GLANDS UNIVERSAL GLAND SUITABLE FOR USE WITH STEEL WIRE ARMOUR, BRAID WIRE ARMOURED AND LEAD SHEATHED CABLES Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath Suitable for circular, Braid wire armour cables with extruded polymeric bedding and oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Continuity Connection for Lead Inner sheathed cables Inner PCP seal grips cable bedding and provides additional ingress protection Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira 02ATEX3093X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range -60 C to +90 C E1W-XL Ex d IIC / Ex e II Cable Gland Kit (KA474 Series) May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex e II equioment Zones 2 with Ex na II equipment Zone 21 & 22 with Ex td A21 Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000cm³ Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000cm³ Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume Zone 2 with Ex nr II equipment Kit comprises: E1W-XL Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Overall Ø (B) Braid Lead Sheath Ø Entry Thread Protrusion Hexagon Qty per Ø (A) Armour Size Armour Thread Length Length Kit Wire Ø Standard Nickel Plated Min Max Min Max Wire Ø Min Max (D) (E) (F) A/F (G) A/C (H) KA KA474-71V 20SS / M20 x KA KA474-52V 20S / / M20 x KA KA474-53V / / M20 x KA KA474-55V / / M25 x KA KA474-56V / / M32 x KA KA474-57V / / M40 x KA KA474-58V 50S / / M50 x KA KA474-59V / / M50 x KA KA474-60V 63S / M63 x KA KA474-61V / M63 x KA KA474-62V 75S / M75 x KA KA474-63V / M75 x KA KA474-64V / M85 x

59 UNIVERSAL GLAND SUITABLE FOR USE WITH BRAID, TAPE AND STEEL WIRE ARMOURED CABLES. Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular cables with braid, tape or wire armour and extruded polymeric bedding & oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Diaphragm inner seal compatible with soft bedding materials that may be subject to cold-flow Suitable for most climatic conditions weatherproof, waterproof and deluge proof Nickel plated versions also available Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira01ATEX1032X Service temperature range 20 C to +90 C Excel Plus Ex d IIC / Ex e II Deluge Proof Cable Gland (493AB Series) May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS CSA certified Ex d ΙΙC & Ex e ΙΙ, CSA Enclosure Type 4X, AEx d ΙΙC & AEx e ΙΙ, NEMA 4X Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Entry Thread Protrusion Hexagon Max Armour Size Thread Length Length Thickness Standard Nickel Plated Min Max Min Max (D) (E) (F) A/F (G) A/C (H) 493AB AB-51V M AB AB-71V 20SS M AB AB-52V 20S M AB AB-53V M AB AB-55V M AB AB-56V M AB AB-57V M AB AB-59V M AB AB-61V M AB AB-63V M

60 HAZARDOUS GLANDS UNIVERSAL GLAND SUITABLE FOR USE WITH BRAID, TAPE AND STEEL WIRE ARMOURED CABLES. Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular cables with braid, tape or wire armour and extruded polymeric bedding & oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Diaphragm inner seal compatible with soft bedding materials that may be subject to cold-flow Suitable for most climatic conditions weatherproof, waterproof and deluge proof Nickel plated versions also available Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira01ATEX1032X Service temperature range 20 C to +90 C Excel Plus (NPT) Ex d IIC / Ex e II Deluge Proof Cable Gland (493NE Series) May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment CSA certified Ex d ΙΙC & Ex e ΙΙ, CSA Enclosure Type 4X, AEx d ΙΙC & AEx e ΙΙ, NEMA 4X Gland Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Entry Thread Protrusion Hexagon Max Armour Size Thread Length Length Thickness Standard Nickel Plated Min Max Min Max (D) (E) (F) A/F (G) A/C (H) 493NE NE-03V ½ ½ NPT NE NE-06V ¾ - 20SS ¾ NPT NE NE-04V ½ - 20S ½ NPT NE NE-07V ¾ - 20S ¾ NPT NE NE-08V ¾ ¾ NPT NE NE-14V NPT NE NE-20V 1¼ ¼ NPT NE NE-27V 1½ ½ NPT NE NE-32V NPT NE NE-38V 2½ ½ NPT NE NE-45V NPT *NPT Threaded glands are supplied as glands only. **Other NPT sizes available upon request. 60

61 UNIVERSAL GLAND SUITABLE FOR USE WITH BRAID, TAPE AND STEEL WIRE ARMOURED CABLES. Brass indoor and outdoor cable gland for use in hazardous areas Suitable for circular cables with braid, tape or wire armour and extruded polymeric bedding & oversheath Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant Three part armour lock provides mechanical cable retention and electrical continuity Diaphragm inner seal compatible with soft bedding materials that may be subject to cold-flow Suitable for most climatic conditions weatherproof, waterproof and deluge proof Nickel plated versions also available Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira01ATEX1032X Service temperature range 20 C to +90 C Excel Plus Ex d IIC / Ex e II Deluge Proof Cable Gland Kit (KA493 Series) May be used in: Zones 0, 1 & 2 with Ex ia ΙΙA, B & C equipment Zones 1 & 2 with Ex ib ΙΙA, B & C equipment Zones 1 & 2 with Ex e ΙΙ equipment Zones 1 & 2 with Ex p ΙΙ equipment Zone 2 with Ex na ΙΙ equipment Zones 21 & 22 with Ex td ΙΙ equipment Where the cable is effectively filled, may also be used in: Zones 1 & 2 with Ex d ΙΙC equipment not containing a source of ignition & with a volume less than 2000 cm³ Zones 1 & 2 with Ex d ΙΙA & Ex d ΙΙB equipment not containing a source of ignition & with any volume Zone 1 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with a volume less than 2000 cm³ Zone 2 with Ex d ΙΙA & Ex d ΙΙB equipment containing a source of ignition & with any volume Zone 2 with Ex nr ΙΙ equipment HAZARDOUS GLANDS CSA certified Ex d ΙΙC & Ex e ΙΙ, CSA Enclosure Type 4X, AEx d ΙΙC & AEx e ΙΙ, NEMA 4X Kit comprises: Excel Plus Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Under Armour Ø (A) Overall Ø (B) Entry Thread Protrusion Hexagon Qty per Max Armour Size Thread Length Length Kit Thickness Standard Nickel Plated Min Max Min Max (D) (E) (F) A/F (G) A/C (H) KA KA493-51V M KA KA493-71V 20SS M KA KA493-52V 20S M KA KA493-53V M KA KA493-55V M KA KA493-56V M KA KA493-57V M KA KA493-59V M KA KA493-61V M KA KA493-63V M

62 HAZARDOUS GLANDS Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas Suitable for circular unarmoured cables with extruded oversheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Provides mechanical cable retention Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Barr-A Ex d IIC Cable Gland (424TA Series) Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira04ATEX1080X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 60 C to +90 C SUITABLE FOR USE WITH CIRCULAR UNARMOURED CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex d IIA, B & C equipment with any volume Zones 1 & 2 with Ex e II equipment Zones 1 & 2 with Ex p II equipment Zone 2 with Ex na II equipment Zone 2 with Ex nr II equipment Zones 21 & 22 with Ext d A21 Gland Reference Cable Dimensions mm Gland Dimensions mm Size Max. Dia. Over Max. No. of Overall Ø (B) Entry Thread Thread Length Protrusion Length Hexagon Standard Nickel Plated Metric NPT Conductors Conductors Min Max (D) (E) (F) A/F (G) A/C (H) 424TA TA-53V M TA TA-55V M TA TA-56V M TA TA-57V M TA TA-59V M TA TA-61V M TA TA-63V M TA TA-64V M TA TA-03V ½ ½ NPT TA TA-05V ¾ ¾ NPT TA TA-06V NPT TA TA-07V 1¼ ¼ NPT TA TA-09V NPT TA TA-11V 2½ ½ NPT TA TA-13V NPT TA TA-14V NPT *Other NPT sizes available upon request. 62

63 Barr-W Ex d IIC Cable Gland (424TW Series) SUITABLE FOR USE WITH STEEL WIRE ARMOURED CABLES Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas Suitable for circular, galvanized steel single wire armour cables with extruded polymeric oversheath and extruded or taped bedding Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Provides mechanical cable retention and electrical continuity through the armour wire termination Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex d IIA, B & C equipment with any volume Zones 1 & 2 with Ex e II equipment Zones 1 & 2 with Ex p II equipment Zone 2 with Ex na II equipment Zone 2 with Ex nr II equipment Zones 21 & 22 with Extd A21 HAZARDOUS GLANDS Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira04ATEX1080X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 60 C to +90 C Gland Reference Cable Dimensions mm Gland Dimensions mm Inner Size Max. Dia. Max. No. Overall Ø (B) Entry Thread Protrusion Hexagon Sheath Ø Armour Over of Thread Length Length Wire Ø Standard Nickel Plated Metric NPT Conductors Conductors Min Max Min Max (D) (E) (F) A/F (G) A/C (H) 424TW TW-52V 20S / 1.4 M TW TW-53V / 1.4 M TW TW-55V / 1.6 M TW TW-56V / 2.0 M TW TW-57V / 2.0 M TW TW-59V / 2.5 M TW TW-61V M TW TW-63V / 3.15 M TW TW-64V / 3.15 M TW TW-02V ½ - 20S / 1.4 ½ NPT TW TW-03V ½ / 1.4 ½ NPT TW TW-05V ¾ / 1.6 ¾ NPT TW TW-06V / NPT TW TW-07V 1¼ / 2.0 1¼ NPT TW TW-09V / NPT TW TW-11V 2½ ½ NPT TW TW-13V / NPT TW TW-14V / NPT *Other NPT sizes available upon request. 63

64 HAZARDOUS GLANDS Barr-X Ex d IIC Cable Gland (424TX Series) SUITABLE FOR USE WITH BRAID ARMOURED CABLES Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas Suitable for circular, wire braid armour cables with extruded polymeric oversheath and extruded or taped bedding Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Provides mechanical cable retention and electrical continuity through the braid wire termination Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex d IIA, B & C equipment with any volume Zones 1 & 2 with Ex e II equipment Zones 1 & 2 with Ex p II equipment Zone 2 with Ex na II equipment Zone 2 with Ex nr II equipment Zones 21 & 22 with Extd A21 Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira04ATEX1080X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 60 C to +90 C Gland Reference Cable Dimensions mm Gland Dimensions mm Size Inner Max. Dia. Max. No. Overall Ø (B) Braid Entry Thread Protrusion Sheath Ø Over of Armour Thread Length Length Hexagon Standard Nickel Plated Metric NPT Conductors Conductors Min Max Min Max Wire Ø (D) (E) (F) A/F (G) A/C (H) 424TX TX-52V 20S / 0.3 M TX TX-53V / 0.3 M TX TX-55V / 0.45 M TX TX-56V / 0.45 M TX TX-57V / 0.45 M TX TX-59V / 0.45 M TX TX-61V / 0.45 M TX TX-63V / 0.45 M TX TX-64V / 0.45 M TX TX-02V ½ -20S / 0.3 ½ NPT TX TX-03V ½ / 0.3 ½ NPT TX TX-05V ¾ / 0.45 ¾ NPT TX TX-06V / NPT TX TX-07V 1¼ / ¼ NPT TX TX-09V / NPT TX TX-11V 2½ / ½ NPT TX TX-13V / NPT TX TX-14V / NPT *Other NPT sizes available upon request. 64

65 Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas Suitable for circular, galvanized steel single wire armour cables with extruded polymeric oversheath and Lead inner sheath Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant Provides mechanical cable retention and electrical continuity through the armour wire termination Provides electrical continuity to the inner lead sheath Suitable for most climatic conditions - weatherproof and waterproof Standard and Nickel plated versions available Full Installation Instructions supplied Barr-PB Ex d IIC Cable Gland (424TP Series) SUITABLE FOR USE WITH FOR LEAD SHEATHED OCMA TYPE CABLES May be used in: Zones 0, 1 & 2 with Ex ia IIA, B & C equipment Zones 1 & 2 with Ex ib IIA, B & C equipment Zones 1 & 2 with Ex d IIA, B & C equipment with any volume Zones 1 & 2 with Ex e II equipment Zones 1 & 2 with Ex p II equipment Zone 2 with Ex na II equipment Zone 2 with Ex nr II equipment Zones 21 & 22 with Extd A21 HAZARDOUS GLANDS Certified ΙΙ 2GD, Ex e ΙΙ & Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN , EN , EN , EN , EN Certificate number Sira04ATEX1080X IECEx Compliance Standards: IEC , IEC , IEC , IEC , IEC Certificate number IECEx SIR X Service temperature range 60 C to +90 C Gland Reference Cable Dimensions mm Gland Dimensions mm Lead Inner Size Max. Dia. Max. No. Sheath Ø Overall Ø (B) Entry Thread Protrusion Hexagon Armour Over of Thread Length Length Wire Ø Standard Nickel Plated Metric NPT Conductors Conductors Min Max Min Max (D) (E) (F) A/F (G) A/C (H) 424TP TP-52V 20S / 1.25 M TP TP-53V / 1.25 M TP-85* 424TP-85V* / 1.25 M TP TP-55 V / 1.6 M TP-86* 424TP-86V* / 1.6 M TP TP-56V / 2.0 M TP TP-57V / 2.0 M TP-89* 424TP-89V* M TP TP-59V / 2.5 M TP TP-61V M TP TP-63V / 3.15 M TP TP-64V / 3.15 M TP TP-02V ½ -20S / 1.25 ½ NPT TP TP-03V ½ / 1.25 ½ NPT TP-35* 424TP-35V* ¾ / 1.25 ¾ NPT TP TP-05V / 1.6 ¾ NPT TP-36* 424TP-36V* / NPT TP TP-06V 1¼ / NPT TP TP-07V / 2.0 1¼ NPT TP-39* 424TP-39V* NPT TP TP-09V 2½ / NPT TP TP-11V ½ NPT TP TP-13V 3" / NPT TP TP-14V 3" / NPT * Sizes 85, 86, 89, 35, 36 & 39 are designated BARR-PBS and are designed to suit smaller diameter armour wires. 65

66 ACCESSORIES CONTENTS Accessories Page PVC Shrouds 401PV 67 PCP shrouds 401AA 67 LSOH Shrouds 401LSF 67 Backnuts (Steel, Brass, Nickel Plated Brass, Aluminium, NPT) 439AA, 429AA ( V ), 429NP, 459AA 68 ACCESSORIES Insulated Adaptor 481AA 68 Earthtags (Brass, Nickel Plated Brass, Aluminium, Brass NPT) 428ET, 428ET ( V ), 458ET, 428NP 69 Nylon Sealing Washer - Metric & NPT Fibre Sealing Washer - Metric & NPT Anti Vibration Fan Disc Washer Adaptor / Reducer - Metric ( + Nickel Plated Version ) 427AD ( V ) 71 Adaptor / Reducer - Metric to NPT ( + Nickel Plated Version ) 427AE ( V ) 71 Adaptor / Reducer - NPT ( + Nickel Plated Version ) 427AN ( V ) 71 66

67 PVC Shrouds UV Resistant PVC shrouds ROHS COMPLIANT Design No. Length A Ø B Ø C Length D Gland Fit BW A1/A2 CW / E type A2EX Excel 401PV / 20ss / 20s 401PV s 20 16/20ss/20s/20 401PV PV PV PV PV s PV PV s / PV s / PV / 20ss 401PV s 401PV PV PV PV s / PV s 401PV PV s 75s / PV s / PV PV PV PV s 401PV PV PV PV PV PV PV PV / 20ss ACCESSORIES PCP Shrouds Polychloroprene Shrouds ROHS COMPLIANT Design No. Length A Length B Ø C Ø D max Ø E min Gland Fit A1/A2 CW / E type 401AA ss/20s/20 16/20ss/20s 401AA AA AA AA s / AA s 50s / AA / 75s / 75 63s / AA s / AA AA s Barrier 401AA AA LSOH Shrouds Silicone LSOH Shrouds COMPLY WITH LU STANDARD FOR INSTALLATION IN ALL SUB-SURFACE LOCATIONS Design No. Length A Length B Ø C Ø D max Ø E min Gland Fit BW A1/A2 CW / E type 401LSF s 20ss/20s/20 16/20ss/20s 401LSF LSF LSF LSF s / LSF s 50s / LSF / 75s / 75 63s / LSF s / 75 75s / 75 67

68 Locknuts Brass, Nickel Plated Brass, Steel & Aluminium FOR SECURING EXTERNAL THREADS INTO NON-THREADED EQUIPMENT Brass, Nickel Plated Brass, Galvanized Steel & Aluminium designs Nickel Plated Brass backnuts should be used with Nickel plated Glands Brass backnuts recommended for most corrosive environments Aluminium backnuts should be used with aluminium glands Steel locknuts are primarily for dry, low humidity environments Thread Size Dimensions mm Brass Brass + nickel plated Steel Aluminium ISO mm NPT Thickness A/F A/C ACCESSORIES 429AA AA-51V 439AA AA AA AA-53V 439AA AA AA AA-55V 439AA AA AA AA-56V 439AA AA AA AA-57V 439AA AA AA AA-59V 439AA AA AA AA-61V 439AA AA AA AA-63V 439AA AA AA AA-64V 439AA AA AA AA-65V AA AA-66V AA AA-67V Ø NP NP-02V 459NP-02 ½ NP NP-03V 459NP-03 ¾ NP NP-04V 459NP NP NP-05V 459NP-05 1 ¼ NP NP-06V 459NP-06 1 ½ NP NP-07V 459NP NP NP-08V 459NP-08 2 ½ NP NP-09V 459NP NP NP-10V 459NP-10 3 ½ Insulated Adaptors Ex d Insulated adaptors provide a method of insulating cable glands from the equipment to which they are fixed. They are used where the enclosure is not relied upon for bonding the cable to the earth, for example: To prevent the heating effects of circulating currents. To segregate low voltage and high voltage earth fault paths. Impact Resistance: 7 Joules Ambient Temperature: -50 C to + 85 C Thread Form: Metric Material: Brass Insulator: 30% glass filled nylon 12 Certified: Exd IIC for hazardous area applications ELECTRICAL PROPERTIES OF INSULATING MATERIAL Dieletrical strength: 90 kv/mm Volume resistivity: 8.6 x ohms/cm Min thickness of insulator: 5mm +/- 1mm 2kV Wet withstand tested Equipment Entry Thread Diam (Male) Gland Entry Thread Diam (Female) Total Length Male Thread Length Female Thread Length Bore Diam 481AA-53 M20 M AA-55 M25 M AA-56 M32 M AA-57 M40 M AA-59 M50 M AA-61 M63 M AA-63 M75 M AA-64 M85 x 2.0 M85 x

69 Earthtags Brass & Aluminium EARTH TAGS PROVIDE AN EARTH BOND CONNECTION BETWEEN THE GLAND AND THE EQUIPMENT Brass, Nickel Plated Brass & Aluminium designs should be selected to match the gland materials. Dimensions mm Brass Brass + nickel plated Aluminium Thread size (A) Bolt Hole Ø B Short Circuit Rating ka 428ET ET-51V 458ET ET ET-53V 458ET ET ET-55V 458ET ET ET-56V 458ET ET ET-57V 458ET ET ET-59V 458ET ET ET-61V 458ET ET ET-63V 458ET ET ET-65V 458ET-65 85/ NP NP-02V ½ NP NP-03V ¾ NP NP-04V NP NP-05V 1 ¼ NP NP-06V 1 ½ NP NP-07V NP NP-08V 2 ½ NP NP-09V NP NP-10V ACCESSORIES All Brass Earth Tags 1.5mm thick, Aluminium 2mm thick 69

Section. Cable Glands. sa B-CABLES nv - T 09/ F 09/

Section. Cable Glands. sa B-CABLES nv - T 09/ F 09/ Cable Glands Section Prysmian Components offer cable glands for a wide range of requirements from simple industrial applications to hazardous areas, on and offshore. All Industrial Cable glands are designed

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN LSOH Wiring Cables Low Voltage (/7 V) LSOH Conduit Wire (HO7ZR) 91B Cable Approvals Cable approved to BS711 Key Applications > Installation in surface mounted or embedded conduits, or similar closed systems

More information

The safety you rely on.

The safety you rely on. Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial

More information

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas.

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas. Aftec is a leading manufacturer of cable glands,cable Connectors and associated accessories, used extensively for power control, lighting and instrumentation cable application in connection with IEC and

More information

Amphenol Cable Glands and Cord Grips Amphenol

Amphenol Cable Glands and Cord Grips Amphenol Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30

More information

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable. ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

CLICK-FIT. High Voltage Accessories for Extruded Cables

CLICK-FIT. High Voltage Accessories for Extruded Cables CLICK-FIT High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy

More information

ADE 6F ADE 6F. page 46

ADE 6F ADE 6F. page 46 ADE 6F 6 F U N C T I O N S : D O U B L E C L A M P I N G > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass standard finishing > Optional : stainless steel, aluminium

More information

Power cable accessories catalogue

Power cable accessories catalogue Power cable accessories catalogue Capability Your connection point Staying up to date with the latest network approval documents can be time consuming and complicated. That s why the Jointing Tech team

More information

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel ADE 4F 4 F U N C T I O N S : D O U B L E > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass and stainless steel > Optional : aluminium and bronze raw material

More information

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Linking the Future As the worldwide leader

More information

CABLES TRADE PRICE LIST

CABLES TRADE PRICE LIST CABLES TRADE PRICE LIST NO. TPR07-3rd September 2009 ENERGY TRADE PRICE LIST TPR07 3rd September 2009 FOR CABLES These cables are sold subject to Prysmian s Standard Conditions of Sale, copies of which

More information

ADJUSTABLE CABLE GLANDS

ADJUSTABLE CABLE GLANDS ISO CE R TIF IC AT N IO Intertek TM MANAGEMENT SYSTEMS ADJUSTABLE CABLE GLANDS NICKEL PLATED BRASS Modest Torque Produces Huge Armour Clamping Forces APPROVED SANS SANS IP If fitted with Gasket, Inner

More information

ADDIMAX CABLE GLANDS FOR INDUSTRIAL USE [ 2 ]

ADDIMAX CABLE GLANDS FOR INDUSTRIAL USE [ 2 ] CABLE GLANDS FOR INDUSTRIAL USE ADDIMAX CABLE GLANDS www.caledonian-cables.co.uk www.addison-cables.com [ 2 ] CONTENT CABLE GLANDS FOR INDUSTRIAL USE... 2 Single Compression A2 Type Weatherproof & Waterproof

More information

As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands.

As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands. Introduction As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands. MASEICO cable glands were designed and manufactured

More information

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire A brand of the Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Capri ADE 6F - for Armoured Cable

Capri ADE 6F - for Armoured Cable Capri ADE 6F - for Armoured Cable Technical Specification Suitable for the following cable types Steel wire armoured cable (SWA) Steel wire braided cable (SWB) Steel tape armoured cable (STA) Braided marine

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

Cable Glands & Accessories

Cable Glands & Accessories Cable Glands & Accessories This catalog features ITC s extensive range of liquid-tight, strain relief cord connectors (cable glands) and accessories, including locknuts, sealing washers, plugs, etc. These

More information

Power cable accessories catalogue

Power cable accessories catalogue Power cable accessories catalogue LV Joints Delivering quality and value every day DELIVERY... Free Next Day Delivery* for orders over 100 STOCK... Millions of items in stock across the U.K SUPPORT...

More information

Cable Connectors GET CONNECTED

Cable Connectors GET CONNECTED Cable Connectors GET CONNECTED Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for

More information

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands KSG, KSGDS and KCG Range of Cable Glands This range of cable glands is intended for use with any cable type where sealing and retention is required by gripping the outer sheath (this includes armoured/screened/braided

More information

cable_glands_en.qxp :25 Uhr Seite 3 cable glands

cable_glands_en.qxp :25 Uhr Seite 3 cable glands cable glands 2 The main focus of our business is on the safety of our customers during their day-to-day work. For over 80 years now, we ve been leading the way in the explosion protection sector in achieving

More information

Installation Guidelines For BW Gland

Installation Guidelines For BW Gland Installation Guidelines For BW Gland Address: Raychem RPG Pvt. ltd. 1/62, M G Road, Off. Western express highway, Near Bharat Petroleum, Valiv Village, Post Sativali, Vasai (E) 401208, Maharashtra, India.

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2010 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY. TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY. Ex cable glands from CMP and R. STAHL. PARTNERSHIP WITH CMP STRENGTHENS POSITION OF R. STAHL AS EX-SYSTEM SUPPLIER The ability to globally deploy

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Annex Page 1 of 8 Equipment: The E** series Type ranges of cable glands consist of a male-threaded front entry component containing an elastomeric sealing ring and a Nylon 6 skid washer which effect flameproof

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22. EX CABLE GLANDS FOR HAZARDOUS AREAS & IECEX Zones, 2, 2 and 22 CABLE GLANDS EX D/E 4 CABLE GLANDS UNARMOURED EX D IP66 - IP68 5 CABLE GLANDS UNARMOURED EX E IP66 - IP68 5 CABLE GLANDS UNARMOURED EX D/E

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

It s time to get connected with

It s time to get connected with It s time to get connected with The essence of quality NEW See pag e6 PRATLEY products and P NUTS are distributed exclusively in the UK by: Cable Connectors Ltd Product Brochure Aluminium Alloy (Corrosion

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

HelaGuard. Non-Metallic Conduit & Fittings

HelaGuard. Non-Metallic Conduit & Fittings HelaGuard Non-Metallic Conduit & Fittings HelaGuard Non-Metallic Conduit Systems Page HelaGuard Overview 3 Conduit Application Overview 4 Mounting & Removing HelaGuard Non-Metallic Fittings 5 HelaGuard

More information

PRODUCT CATALOG. Cable glands for Global Applications

PRODUCT CATALOG. Cable glands for Global Applications PRODUCT CATALOG Cable glands for Global Applications 2 CABLE GLANDS FOR HAZARDOUS & INDUSTRIAL APPLICATIONS ABB provides renowned cable protection solutions, including conduit systems and cable glands

More information

SEMI, manufacturer of superior quality electrical flexible conduit and fittings systems. Over Braided Liquid Tight Conduit ( YF-705 )

SEMI, manufacturer of superior quality electrical flexible conduit and fittings systems. Over Braided Liquid Tight Conduit ( YF-705 ) Over Braided Liquid Tight Conduit ( YF-705 ) Trade Size I.D. (mm) O.D. (mm) Min Bending MIN. MAX. MIN. MAX. Meters/Coil YF-70503 3/8" 12.3 12.8 18.5 19.0 75 50 YF-70504 1/2" 15.7 16.3 21.8 22.3 95 50 YF-70506

More information

FHL. Ex d. Body in aluminium

FHL. Ex d. Body in aluminium Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate

More information

Powerline QC. Single Power Connectors. Ten 47 Limited

Powerline QC. Single Power Connectors. Ten 47 Limited Powerline QC Single Power Connectors Ten 47 Limited Unit 2B Frances Industrial Park Kirkcaldy, Scotland, UK KY1 2XZ Tel: +44 (0)1592 655725 Fax: +44 (0)1592 651049 Email: sales@ten47.com www.ten47.com

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

Cable Management Solutions. HelaGuard. Non-Metallic Conduits and Fittings

Cable Management Solutions. HelaGuard. Non-Metallic Conduits and Fittings Cable Management Solutions HelaGuard Non-Metallic Conduits and Fittings Table of Contents Page HelaGuard Overview 4 Conduit Application Overview 6 Mounting & Removing HelaGuard Non-Metallic Fittings 7

More information

Global Cable Gland Solutions

Global Cable Gland Solutions Global Cable Gland Solutions Global Cable Gland Solutions For more than 100 years, companies have come to rely on Cooper Crouse-Hinds for value they can trust to grow their business. Our comprehensive

More information

Global Cable Gland Solutions

Global Cable Gland Solutions Global Cable Solutions Global Cable Solutions For more than 100 years, companies have come to rely on Cooper Crouse-Hinds for value they can trust to grow their business. Our comprehensive offering of

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

Pratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box

Pratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box Pratley Ezee-Fit Box Covers Ex e/n Either standard or polycarbonate (transparent) Supplied complete with stainless steel cheese head screws and rubber gasket ready to fit Pratley Ezee-Fit Box Replacement

More information

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810

More information

12:20 12:21 A2F 12:22 E1WF & 12:23 E1XF & 12:24 & & 12:25 & & 12:26 E2WF (RTLF) & 12:27 12:28 12:29 12:30 12:30 & 12:31 PCP/PVC

12:20 12:21 A2F 12:22 E1WF & 12:23 E1XF & 12:24 & & 12:25 & & 12:26 E2WF (RTLF) & 12:27 12:28 12:29 12:30 12:30 & 12:31 PCP/PVC CONTENT Introduction to Glands... :2 I.P Ratings for Cable Glands...:4 A1/A2 Brass Gland with Outer eal... :6 CX Brass Gland with Outer eal...:7 CXT Brass Gland with Outer eal... :8 Ultech Nylon Gland...

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable 0.6/1kV Al-Cu XLPE Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS 1.IEC;VDE ;ICEA;AS/NZS; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number of cores : One core, two cores, three cores, 3+1 cores,

More information

Empty enclosures IEC 62208

Empty enclosures IEC 62208 374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series

More information

Steel Conduits Conduit Fittings Flexible Conduits

Steel Conduits Conduit Fittings Flexible Conduits Conduits Conduit Fittings Flexible Conduits CONTENT 1. INTRODUCTION VOLTECX products introduction and selecting VOLTECX 2. STEEL CONDUITS VOLTECX BS4568: Part 1: 1970 (Class 4) Conduit IEC 61386-21:2004;

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

LMV RANGE CONTENTS. General information

LMV RANGE CONTENTS. General information General information LMV RANGE CONTENTS Basic safety information. 2 Main features...... 3 Intermateability.. 3 Characteristics....... 4 Connection system.... 4 Ordering information Standard connector part

More information

LUGS GLANDS & LUGS GLANDS A2/BW/CW. TAN TECK SENG Electric Co. (Pte) Ltd 2009/2010

LUGS GLANDS & LUGS GLANDS A2/BW/CW. TAN TECK SENG Electric Co. (Pte) Ltd 2009/2010 2009/2010 GLANDS & LUGS GLANDS A2 Industrial Gland BW Armoured Gland CW Armoured Gland A2/BW/CW LUGS Project Title Ping Yi Secondary School Linear Factory Draycott Park Condominium Sentosa Monorail Spring

More information

Dimensions / Order Codes

Dimensions / Order Codes U-Bolt Clamps Dimensions / Flat Steel U-Bolt with Plastic Pipe Saddle (Short) and U-Profile Type FB+RUK (To be used as Fixed Point Clamps only) B1 ø D1 H4 H2 H3 H1 L2 L1 B2 Flat Steel U-Bolt (type FB)

More information

Rail product accessories catalogue

Rail product accessories catalogue Rail product accessories catalogue Capability Your connection point Staying up to date with the latest network approval documents can be time consuming and complicated. That s why the Jointing Tech team

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

GEMSCAB has been associated with marketing and manufacturing of Electric Cables I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables cmi XLPE s PRODUCT CATALOGUE Electric Wire & s Complies to AS/NZ Standard cmi XLPE s www.cmielectrical.com.au A division of CMI Operions Pty Ltd ABN 87 088 279 270 For over 15 years XLPE s has provided

More information

ENYSTAR Load Centers up to 250 A

ENYSTAR Load Centers up to 250 A PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

Industry Cables Special cables for industrial applications General Catalogue

Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the

More information

IP44 - IP66 Rated RCD, Power & Cable Management

IP44 - IP66 Rated RCD, Power & Cable Management IP44 - IP66 Rated RCD, Power & Cable Management IP54 Rated 10 amp Switches IP66 Rated 10 amp Switches IP66 Rated 13 amp Sockets IP66 13 amp RCD switched Socket IP66 13 amp unswitched socket with timer

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

Cable Accessories. Product Catalogue

Cable Accessories. Product Catalogue Cable Accessories Product Catalogue 2017 2 P age REPL INTERNATIONAL REPL HAVE BEEN DESIGNING AND MANUFACTURING CABLE ACCESSORIES FOR USE ON ENERGY AND TELECOM CABLES FOR OVER 35 YEARS. WE SUPPLY OUR PRODUCTS

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

ZHPCG CK0226 POWER CABLE WIRE & CABLE

ZHPCG CK0226 POWER CABLE WIRE & CABLE ZHPCG CK0226 POWER CABLE WIRE & CABLE ZHPCG CK0226 POWER CABLE WIRE & CABLE Application/Use Rail approved zero Halogen Power Cables, available as 750V or 1800V rated. ZHPCG cables are all Halogen free,

More information

H e a t s h r i n k P r o d u c t G u i d e

H e a t s h r i n k P r o d u c t G u i d e P o w e r P r o d u c t s H e a t s h r i n k P r o d u c t G u i d e Introduction HellermannTyton is a world leader in providing systems and solutions for heatshrink applications. HellermannTyton utilises

More information

Powerline. Single Power Connectors. Ten 47 Limited

Powerline. Single Power Connectors. Ten 47 Limited Powerline Single Power Connectors Ten 47 Limited Unit 2B Frances Industrial Park Kirkcaldy, Scotland, UK KY1 2XZ Tel: +44 (0)1592 655725 Fax: +44 (0)1592 651049 Email: sales@ten47.com www.ten47.com Introduction

More information

Cable Glands for Hazardous Areas

Cable Glands for Hazardous Areas Cable Glands for Hazardous Areas Cable Glands for Hazardous Areas Ex d Ex e 2 Registered HUMMEL AG For over 60 years HUMMEL AG has provided outstanding EXIOS should be the new choice of specification solutions

More information

Welcome to INTERTECH

Welcome to INTERTECH Welcome to INTERTECH Intertech Engineering designs, supplies and installs cable accessories for power transmission and distribution. Our wide range of products is suitable for applications from 6.6kV to

More information

HAZ PRO ELECTRICAL ENGINEERING SOLUTIONS HAZ-PRO CONDUIT SYSTEM TECHNOLOGY (+61)

HAZ PRO ELECTRICAL ENGINEERING SOLUTIONS HAZ-PRO CONDUIT SYSTEM TECHNOLOGY   (+61) 2019.1.1 ELECTRICAL ENGINEERING SOLUTIONS HAZ-PRO CONDUIT SYSTEM HAZ PRO TECHNOLOGY Laptem Engineering Solutions Head Office: Bassendean WA Distribution Centre: Acacia Ridge QLD Distribution Centre: Clayton

More information

AXIS. Cable Glands AAG ABW ABWL ABXL ACWG ACXG ACZG AE1W AE1X AE1Z AGXD AWG CONTENTS CAT #

AXIS. Cable Glands AAG ABW ABWL ABXL ACWG ACXG ACZG AE1W AE1X AE1Z AGXD AWG CONTENTS CAT # able Glands XIS ONTNTS 1/2 Industrial able Gland W Industrial able Gland WL Heavy uty Industrial able Gland XL Industrial able Gland W Industrial able Gland X Industrial able Gland Z Industrial able Gland

More information

Pressure and Temperature Switches

Pressure and Temperature Switches Pressure and Temperature Switches Model 4140 Typical applications Suitable for industrial and marine applications Providing protection and safety of: --Diesel engines --Compressors --Pumps --Transmissions

More information

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE Instrum LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE (AI364 Rev 11 05Oct17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161

More information