CLEVELAND CABLE LOCATIONS

Size: px
Start display at page:

Download "CLEVELAND CABLE LOCATIONS"

Transcription

1 A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2010

2 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS

3 3 As is illustrated within our catalogue, we stock a comprehensive range of cables for every conceivable application. All types shown are considered as standard items to our range and are always available for immediate delivery. Our stocks are extremely large and unrivalled in the industry. We are fortunate to have a very experienced and dedicated team of people who are able to assist and advise. Additionally our policy of continuing investment in the best available technology, warehousing, handling and measuring equipment and delivery vehicles enables us to guarantee all our customers an extremely high quality service. CLEVELAND CABLE COMPANY Enquiries are welcome from customers worldwide. Our export service is efficient and reliable with the ability to ship by air or sea freight to any destination. Please feel free to contact the distribution centre of your choice for an immediate, professional and trouble free service. Middlesbrough Bristol Glasgow Milton Keynes London Newcastle Warrington

4 4 CLEVELAND CABLE COMPANY CLEVELAND CABLE COMPANY Cleveland Cable Company, established in 1978, is undoubtedly the foremost distributor of electrical cables in Great Britain and possibly Europe. The Head Office and principal stocking location is located at Middlesbrough in the North East of England. This site covers an area of twelve acres and includes over 160,000 square feet of warehousing. Additionally there are regional depots at Bristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each location holds comprehensive stocks and is equipped with the most modern handling and measuring equipment. Deliveries are made by our own fleet of purpose-designed vehicles, all of which are fitted with hydraulic lifting equipment for safe offloading onsite and also efficient collection of empty drums.

5

6 MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD

7 LAND ACQUIRED FOR FUTURE DEVELOPMENT MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD

8 8 GLAND SELECTION GUIDELINES There are many factors to be considered when selecting cable glands for industrial installations. Neglecting to give due attention to these factors could cause unnecessary difficulties at a crucial point in time where most inconvenience and expense can result. It is most desirable to avoid discovering that, once all other equipment is on site or installed, the glands have not been ordered or are the wrong size or type. Good practice would be to allocate some planning and preparation time to cable gland selection. This will help avoid the possible disruption which could result at a critical point of the installation process. In the event of a project schedule of cables being available Cleveland Cable Company are happy to offer a gland selection and sizing service. Please contact any of our depots for further information or assistance. Here is a summary of some aspects to carefully consider when selecting cable glands. Identify the type of cable to be used. Check the construction, size and material properties of the cable. Check the type and material of the cable armour (*) Check the short circuit fault current rating of the cable armour (**) Check the actual diameter of the inner bedding (where present) against this catalogue. Check the actual diameter of the lead covering (where present) against this catalogue. Check the actual size of the overall cable diameter against this catalogue. Check the size and type or armour or braid (where present) against this catalogue. Check any special environmental requirements in relation to corrosion protection. Check the material of the mating electrical enclosures to eliminate dis-similar metals. Consider whether any protective plating is required to be applied to the cable gland. Check the type and size of the cable entry hole in the mating electrical equipment. Check the ingress protection rating of the electrical equipment or site standard. Check whether a single or double seal cable gland is required. Check whether an entry thread seal is required for IP66 (or IP67/IP68) conditions. Check whether fixing accessories such as locknuts and serrated washers are required. Check whether earth tags are required. (**) Check whether shrouds are required. Select a corresponding cable gland type from this catalogue. For installations in Hazardous Areas, special considerations should be taken into account to ensure compliance with national or international codes of practice. Check whether a thread conversion adaptor or reducer is required to make the installation. Select corresponding adaptors or reducers from this catalogue. Check whether any stopper plugs are required to close unused cable entries. Select corresponding stopper plugs from this catalogue. Note (*): If the cable armour is of a non standard material, i.e. Aluminium Wire Armour, it may be necessary to consider an alternative cable gland material, e.g. Aluminium. Note (**): For certain medium voltage and high voltage cables where the fault current carrying capacity of the cable armour is greater that that of the standard earth tag it may be necessary to consider a cable gland utilising the a heavy Cast Integral Earth Lug (CIEL) option which can be identified in the body of this catalogue.

9 9 SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables 6491X (HO7V-R) PVC insulated wiring, 1.5mm 2 630mm Bare copper strand, soft drawn to BS6360/81, 6mm 2-400mm Y PVC insulated, PVC sheathed surface wiring, 1.5mm 2 120mm *Y PVC insulated, PVC sheathed surface wiring, 1mm 2 16mm CONTENTS BS5467 Mains & control, XLPE, PVC SWA, PVC, 1.5mm 2 16mm 2 including multicores...16 BS5467 Mains, XLPE, PVC, SWA, PVC, copper conductors, 25mm 2 400mm BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 4mm 2 16mm BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 25mm 2 400mm BS5467 Mains, XLPE, PVC, SWA, PVC, aluminium conductors, 25mm 2 300mm BS7889 Mains, single core, XLPE, PVC, non-armoured, 50mm mm BS5467 Mains, single core, XLPE, PVC, aluminium wire armoured, PVC, 50mm mm Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% Conductivity in armour, 10mm 2 300mm EEMUA 133 Multicore, XLPE, lead sheathed, PVC, SWA, PVC, Control cable for petro-chemical industries, 1.5mm 2 4mm EEMUA 133 Mains, XLPE, lead sheathed, PVC,SWA, PVC, for petro-chemical industries, 1.5mm 2 16mm EEMUA 133 Mains, XLPE, lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 25mm 2 300mm Cathodic Protection Cables. XLPE, PVC, and XLPE, PVC, SWA, PVC, 6mm 2 185mm Concentric, split & straight, single phase service cable, 4mm 2 35mm SECTION V Mains Cable BS5467 Mains, single core XLPE, PVC, aluminium wire armoured, PVC, 3300V, 120mm2 630mm BS5467 Mains three core, XLPE, PVC, SWA, PVC, 3300V, 16mm 2 300mm Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% conductivity in armour, 3300V, 16mm 2 300mm EEMUA 133 Mains, XLPE, Lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 3300V, 25mm 2 300mm SECTION 3 LSZH Fixed Wiring & Mains Cables 6491B (H07Z-R) LSZH insulated wiring, 1.5mm 2 630mm B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm 2 120mm *B LSZH insulated, LSZH sheathed surface wiring 1.5mm 2 16mm BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm 2 16mm 2 including multicores...38 BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm 2 400mm BS6724 Mains, single core, XLPE, LSZH, 50mm mm

10 10 CONTENTS BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm mm BS8436 Protected fixed wiring cable, 1mm 2 10mm SECTION 4 Medium Voltage 11000V & above BS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC, 11000V, 50mm 2 630mm...44 BS6622 Mains, three core, XLPE, CTS, PVC, SWA, PVC, 11000V, 25mm 2 400mm BS6622 Mains, three core, aluminium conductor XLPE, CTS, PVC, SWA, PVC, 11000V, 95mm2 300mm Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000V, utility cable, 70mm 2 300mm Paper insulated, BS6480 Mains, three core, SWA, PVC, 11000V, 25mm 2 400mm BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000V, 50mm 2 630mm BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000V, 35mm 2 400mm BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000V and 33000v, 95mm2 185mm SECTION 5 High voltage 33000v service and windfarm cables BS7870 Mains, single core, aluminium conductors, XLPE, CWS, MDPE, 33000v 70mm 2 630mm BS7870 Mains, single core, copper conductors, XLPE, CWS, MDPE, 33000v 70mm 2 630mm SECTION 6 Fire Protection, Alarm & Security Cables Mineral Insulated...56 BS5839/BS7629 Fire performance alarm and security cable, 1mm 2 4mm BS5839/BS7629 Enhanced fire performance alarm and security cable 1.5mm 2 4mm BS6387 Fire performance single core cable, 1.5mm 2 16mm BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,1.5mm 2 16mm 2, including multicores...60 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm 2 400mm BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant, enhanced, 1.5mm 2 16mm 2, including multicores...62 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced, 25mm 2 400mm

11 11 SECTION 7 Flexible Cables, PVC and Rubber PVC and LSZH flexible cables 218*Y (H03VV-F) PVC, PVC, 0.5mm mm *Y (H05VV-F) PVC, PVC, 0.5mm 2 2.5mm *Y Heat resisting PVC, PVC, 0.5mm 2 2.5mm Arctic grade low temperature flex, 1.5mm 2 6mm *B (H05ZIZI-F) LSZH, LSZH, 0.75mm 2 2.5mm YY Control cable, 0.75mm 2 1.5mm YY Control cable, 2.5mm 2 50mm SY Control cable, 0.75mm 2 2.5mm SY Control cable, 4.0mm 2 95mm CY Control cable, 0.5mm 2 16mm YY Control cable, LSZH, 0.75mm 2 25mm CY Control cable, LSZH, 0.75mm 2 1.5mm Tri-rated and Bi-rated BS6231, switchgear and control panel wire, 0.5mm 2 400mm Y PVC, PVC, 6mm 2 400mm B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring, 1.5mm 2 240mm Rubber flexible cables BS6500 EPR insulated, CSP sheathed, flexible power & control, mm BS7919 EPR insulated, CSP sheathed, flexible mains 4mm 2 16mm BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm 2 630mm HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm 2 50mm HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm 2 630mm *P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm 2 16mm BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm 2 2.5mm Coil lead BS6195 EPR, CSP, 0.5mm 2 400mm Welding cable, O361TQ EPR, CSP, 16mm 2 185mm Flatform and silicon cables Flatform cable, PVC, PVC, 1.5mm 2 95mm Flatform cable, EPR, PCP, 1.5mm 2 70mm Silicon insulated, silicon sheathed, flexible cable, 0.75mm 2 2.5mm CONTENTS SECTION 8 Instrumentation, Control & Communication Cables BS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm 2 2.5mm 2, part 1 and part BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm 2 1.5mm 2, part 1 and part

12 12 CONTENTS BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm 2 1.5mm 2, part 1 and part BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen, 0.75mm 2 1.5mm 2, part 1 and part BS5308 part 1 core identification...96 BS5308 part 2 core identification...97 British Steel specification CES20 type 134, 0.75mm British Steel specification CES20 type 143, 0.75mm CW1308 telephone cable Telephone cable to EATS 09-6 standard...101/102/103 EATS 09-6 section 3.6 core identification EATS 09-6 section 4.5 core identification Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS Defence standard screened cable type Defence standard parts 4 & 5 core identification Thermocouple extension and compensating cable, 0.75mm Thermocouple core identification Traffic signal cable, loop feeder cable and loop detector cable...110/111 SECTION 9 Data Cables Belden equivalents Coaxial cables Cat 5 data cables SECTION 10 Railway Cables Signalling cable types A1, A2, A3, B1 and B2, 0.75mm 2 95mm Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm 2 35mm Train protection warning system cable Point heater cable Axle counting cable...119/120 Datalink cable Copper trackside cable Power cables, 16mm 2 95mm Trackfeeder cables, 150mm mm SECTION 11 Marine and Offshore Cables EPR insulated, non-armoured shipwiring cable, 1.5mm 2 6mm EPR insulated, non-armoured shipwiring cable, 10mm 2 630mm EPR insulated, braided armoured shipwiring cable, 1.5mm 2 4mm EPR insulated, braided armoured shipwiring cable, 6mm 2 300mm EPR insulated, single core braided shipwiring cable, 6mm 2 630mm SECTION 12 Installation Accessories...129

13 13 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC

14 14 FIXED WIRING AND MAINS CABLES PVC 6491X (HO7V-R) PVC Stranded plain annealed compacted circular copper conductor, PVC outer sheath. Ref 6491X. Harmonised code HO7V-R. 450 volts grade to BS6004. Flame propagation to BS EN CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS A2 NYLON A2 CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) 6491X1/ / / X2/ / / X / / X / / X / / X / / X / S X / S X / X / X / X / X / X / X / X / X / X / S X / S 50 PVC INSULATED WIRING CABLE 6491X (1.5MM 2 TO 630MM 2 ) AND BARE COPPER STRAND (6MM 2 TO 400MM 2 ) -15 to +70 C. up to 10mm 2-3 x overall diameter. above 25mm 2-6 x overall diameter. Standard colours available: 1.5mm 2 & 2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. 4mm 2-630mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +60 C. BARE COPPER STRAND Stranded plain annealed compacted circular copper conductor, non insulated and non sheathed. 450 volts grade, soft drawn to BS6360/81. CCC CONDUCTOR STRANDING WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / CB / to + 70 C Up to 10mm - 3 x overall diameter. Above 25mm - 6 x overall diameter.

15 15 SURFACE WIRING CABLES PVC 6181Y Plain annealed stranded circular copper conductor, single core, PVC insulated, PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey or Blue/Grey. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6181Y / / Y1/ / / Y2/ / / Y / / Y / / Y / S Y / S Y / Y / Y / Y / Y Y / FIXED WIRING AND MAINS CABLES PVC PVC INSULATED PVC SHEATHED SURFACE WIRING CABLE TYPE 6181Y (1MM 2 TO 120MM 2 ) PVC INSULATED PVC SHEATHED WIRING CABLE TYPE 624*Y (1MM 2 TO 16MM 2 ) -15 to +70 C. up to 10mm 2-3 x overall diameter. over 10mm 2-4 x overall diameter. temperatures below 0 C or above +60 C. SURFACE WIRING CABLES PVC 624*Y Plain annealed copper conductor, PVC insulated one, two or three cores laid flat with an uninsulated circuit protective conductor and PVC sheathed. Grey. Ref 6241/2/3Y 300/500 V to BS6004. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER (MM) (MM) 6241Y1BR 1.0 1/ X Y1/5BR 1.5 1/ X Y / X Y1/ / X Y1/5BRBR 1.5 1/ X Y2/ / X Y / X Y / X Y / X Y X Y / X Y1/ / X Y2/ / X to +70 C. Fixed 3 x overall diameter. temperatures below 0 C or above +60 C.

16 16 FIXED WIRING AND MAINS CABLES PVC MAINS AND CONTROL CABLES PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) XLPE2X1/ / / XLPE3X1/ / / XLPE4X1/ / / XLPE5X1/ / S 0.6 XLPE7X1/ / S 0.6 XLPE8X1/ / XLPE10X1/ / XLPE12X1/ / XLPE19X1/ / XLPE27X1/ / XLPE37X1/ / XLPE48X1/ / XLPE2X2/ / S 0.5 XLPE3X2/5* 2.5 7/ S 0.6 XLPE4X2/ / S 0.6 XLPE5X2/ / S 0.6 XLPE7X2/ / XLPE10X2/ / XLPE12X2/ / XLPE19X2/ / XLPE27X2/ / XLPE37X2/ / XLPE48X2/ / XLPE2X / S 0.6 XLPE3X4* 4.0 7/ S 0.6 XLPE4X / XLPE5X / XLPE7X / XLPE12X / XLPE19X / XLPE27X / XLPE2X / S 0.6 XLPE3X6* 6.0 7/ XLPE4X / XLPE5X / XLPE7X / XLPE2X / XLPE3X10* / XLPE4X / XLPE5X / XLPE7X / XLPE2X / XLPE3X16* / XLPE4X / XLPE5X / XLPE7X / XLPE INSULATED MAINS AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -15 to +90 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - up to 6mm 2 - White with Black numbers. 5 core - 10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow 1.5 & 2.5-2,3,4 core also available in white numbered cores to ESI 09-6 temperatures below 0 C or above +60 C. * Additionally these cables are stocked with Brown, Blue and Green/Yellow core identification.

17 17 MAINS CABLES PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6942X / X / X / X / X / X / X / X / X / X / X / X / X / X / X / X / S X / X / X / S X / TC9 6942X / X / S X / X / X / X / X / X / X / S TC9 6942X / X / S TC9 6944X / TC X / X / TC X / S TC X / S TC9 6943X / S TC X / TC12 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE (25MM 2 TO 400MM 2 )

18 18 FIXED WIRING AND MAINS CABLES MDPE SHEATHED MDPE SHEATHED FIXED WIRING AND MAINS CABLES MDPE SHEATHED Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT 6942PE / S PE / S PE / S PE / S PE / S PE / PE / PE / PE / PE / PE / PE / PE / to + 90 C 8 x Overall Diameter 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C. FIXED WIRING AND MAINS CABLES MDPE (4MM 2 TO 16MM 2 ) Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

19 19 FIXED WIRING AND MAINS CABLES MDPE SHEATHED Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT 6942PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / PE / S PE / PE / PE / S PE / PE / PE / S PE / PE / PE / S PE / TC9 6942PE / S PE / PE / S TC9 6942PE / PE / S TC9 6944PE / TC PE / TC9 6943PE / TC PE / S TC PE / S TC PE / TC14 FIXED WIRING AND MAINS CABLES MDPE SHEATHED - 15 to + 90 C temperatures below 0 C or above 40* C. 8 x Overall Diameter 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. FIXED WIRING AND MAINS CABLES MDPE (25MM 2 TO 400MM 2 ) Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

20 20 FIXED WIRING AND MAINS CABLES PVC MAINS CABLES WITH ALUMINIUM CONDUCTORS PVC Solid plain aluminium sectoral conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) SAC4X SAC4X SAC4X SAC4X SAC4X SAC4X S 1.8 SAC4X SAC4X TC9 SAC4X S TC9 SAC4X TC10-15 to +90 C. 8 x overall diameter. Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE WITH ALUMINIUM CONDUCTORS (25MM 2 TO 300MM 2 )

21 21 SINGLE CORE NON-ARMOURED MAINS CABLES PVC Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97. Flame propagation to BS EN CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS NYLON SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER A2 A2 CLEAT CLEAT (MM) 6181X / X / X / X / X / X / X / X / AC X / S AC X / S AC X / AC X / S AC X / TC9 376AC19 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 8 x overall diameter. Brown inner / Black outer. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE CORE NON-ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )

22 22 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES Stranded plain annealed compacted circular copper conductors, XLPE insulated, PVC bedding, aluminium wire armoured, PVC outer sheath. Black. 600/100 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND GLAND SINGLE TREFOIL CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE CLEAT CLEAT ALI(MM) BRASS A2 (MM) 6941AX / AX / AX / AX / AX / AX / AC AX / S AC AX / S AC AX / AC AX / S 63S AC AX / S AC AX / S 75S TC9 376AC AX / S 75S TC10 376AC22-15 to + 90 C 6 x Overall Diameter Brown inner - Black outer temperatures below 0* C or above +60* C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )

23 23 MAINS CABLES FOR MINES & QUARRIES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000 volts grade generally to BS5467 and BC295. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) NCB3X10/1 10 7/ NCB4X10/1 10 7/ NCB3X16/1 16 7/ NCB4X16/1 16 7/ NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / NCB3X / NCB4X / S 1.6 NCB3X / S 1.6 NCB4X / S 2.0 NCB3X / S 1.8 NCB4X / NCB3X / NCB4X / S TC9 NCB3X / S TC9 NCB4X / TC10 NCB3X / TC10 NCB4X / S TC11 FIXED WIRING AND MAINS CABLES PVC -15 to +70 C. up to 16mm 2-6 x overall diameter. over 16mm 2-8 x overall diameter. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (10MM 2 TO 300MM 2 )

24 24 FIXED WIRING AND MAINS CABLES PVC EEMUA133 CONTROL CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores white with black numbers. 600/1000 volts grade to BS5467 and EEMUA 133. Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X1/5ESI 1.5 7/ EEMUA3X1/5ESI 1.5 7/ EEMUA4X1/5ESI 1.5 7/ EEMUA5X1/ / EEMUA7X1/ / EEMUA12X1/ / EEMUA19X1/ / EEMUA27X1/ / EEMUA37X1/ / EEMUA2X2/5ESI 2.5 7/ EEMUA3X2/5ESI 2.5 7/ EEMUA4X2/5ESI 2.5 7/ EEMUA5X2/ / EEMUA7X2/ / EEMUA12X2/ / EEMUA19X2/ / EEMUA27X2/ / EEMUA37X2/ / EEMUA5X / EEMUA7X / to +90 C. 12 x overall diameter. White with Black numbers. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED CONTROL CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM 2 TO 4MM 2 )

25 25 EEMUA133 MAINS CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X1/ / EEMUA3X1/ / EEMUA4X1/ / EEMUA2X2/ / EEMUA3X2/ / EEMUA4X2/ / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 12 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM 2 TO 16MM 2 )

26 26 FIXED WIRING AND MAINS CABLES PVC EEMUA133 MAINS CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / EEMUA2X / EEMUA3X / EEMUA4X / S 1.8 EEMUA2X / EEMUA3X / S 1.8 EEMUA4X / EEMUA2X / S 1.6 EEMUA3X / EEMUA4X / S TC9 EEMUA2X / S 1.8 EEMUA3X / TC9 EEMUA4X / S TC10 EEMUA2X / EEMUA3X / S TC9 EEMUA4X / TC11 EEMUA2X / TC9 EEMUA3X / TC10 EEMUA4X / S TC11 EEMUA2X / TC11 EEMUA3X / S TC12-15 to +90 C. 12 x overall diameter. 2 core - Brown, Blue 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (25MM 2 TO 300MM 2 )

27 27 SINGLE CORE NON-ARMOURED CATHODIC PROTECTION CABLES PVC Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer sheath, 600/1000 volts grade generally to BS5467 & IEC Colours Black/Black or Red/Red. CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 6181X6 6 7/ / X / / X / S 6181X / S 6181X / X / X / X / X / X / X / FIXED WIRING AND MAINS CABLES PVC 4 x overall diameter. temperatures below 0 C or above +60 C. XLPE INSULATED NON- ARMOURED AND ARMOURED SINGLE CORE CABLE FOR CATHODIC PROTECTION (6MM 2 TO 185MM 2 ) SINGLE CORE ARMOURED CATHODIC PROTECTION CABLES PVC Plain annealed compacted circular copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade generally to IEC & BS5467. CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 6941X6 6 7/ / X / / X / S 6941X / S 6941X / X / X / X / X / X / X / x overall diameter. temperatures below 0 C or above +60 C.

28 28 FIXED WIRING AND MAINS CABLES PVC SPLIT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, XLPE insulated surrounded by a concentric layer of plain annealed solid copper neutral conductors. XLPE insulated and plain annealed solid strand bare copper earth conductors, PVC outer sheath. Black. 600/1000 volts grade to BS CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 4 SPLITCON 4 7/ S 6 SPLITCON 6 7/ SPLITCON 10 7/ SPLITCON 16 7/ SPLITCON 25 *7/ SPLITCON 35 7/ * Stranding of neutral is the same as phase conductor except 25 sq mm which has 11 x 1.70mm. Conductor identification: Brown Live/Blue Neutral. temperatures below 0 C or above +60 C. Also available in Violet outer sheath in 6mm, 10mm, 16mm & 25mm. STRAIGHT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, PVC insulated surrounded by a concentric layer of plain annealed solid copper neutral/earth conductors in concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 & ESI Combined neutral and earth (CNE). CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 4 STRCON 4 7/ S 6 STRCON 6 7/ S 16 STRCON 16 7/ STRCON 25 7/ STRCON 35 7/ to +70 C. 10 x overall diameter. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE PHASE SPLIT AND STRAIGHT CONCENTRIC SERVICE CABLE (4MM 2 TO 35MM 2 )

29 29 FIXED WIRING AND MAINS CABLES 3300V PVC FIXED WIRING AND MAINS CABLES PVC

30 30 FIXED WIRING AND MAINS CABLES PVC SINGLE CORE ARMOURED MAINS CABLES 1900/3300V Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT (MM) (MM) 6941AX120/ / AX150/ / AX185/ / AC AX240/ / AC AX300/ / AC AX400/ / S AC AX500/ / S AC AX630/ / AC15-25 to +90 C. 6 x overall diameter. Brown inner/black outer. temperatures below 0 C or above +60 C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE 3300V (120MM 2 TO 630MM 2 )

31 31 3 CORE MAINS CABLES 1900/3300V PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) XLPE3X16/3 16 7/ XLPE3X25/3 25 7/ XLPE3X35/3 35 7/ XLPE3X50/ / XLPE3X70/ / XLPE3X95/ / S 1.8 XLPE3X120/ / S 1.8 XLPE3X150/ / XLPE3X185/ / TC9 XLPE3X240/ / S TC9 XLPE3X300/ / TC10 XLPE3X400/ / S TC11-15 to +90 C. 8 x overall diameter. Brown, Black, Grey. temperatures below 0 C or above +60 C. FIXED WIRING AND MAINS CABLES PVC XLPE INSULATED MAINS CABLE 3300 VOLT (16MM 2 TO 400MM 2 )

32 32 FIXED WIRING AND MAINS CABLES PVC MAINS CABLES FOR MINES & QUARRIES 1900/3300V Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 1900/3300 volts grade generally to BS5467 and BC295. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) NCB3X16/3 16 7/ NCB3X25/ / NCB3X35/ / NCB3X50/ / NCB3X70/ / NCB3X95/ / S 1.8 NCB3X120/ / S 1.8 NCB3X150/ / NCB3X185/ / TC9 NCB3X240/ / S TC9 NCB3X300/ / TC10-15 to +70 C. up to 16mm 2-6 x overall diameter. over 16mm 2-8 x overall diameter. 3 core - Brown, Black, Grey temperatures below 0 C or above +60 C. XLPE INSULATED MAINS CABLE 3300V WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (16MM 2 TO 300MM 2 )

33 33 EEMUA133 MAINS CABLES 1900/3300V PVC Plain annealed stranded copper conductors, XLPE insulated, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN Flame propagation to BS EN (IEC ), bunched cables to BS EN (IEC category A) and BS EN (IEC category C). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) EEMUA3X25/3 25 7/ EEMUA3X35/ / EEMUA3X50/ / EEMUA3X70/ / S 1.8 EEMUA3X95/ / S 2.0 EEMUA3X120/ / EEMUA3X150/ / TC9 EEMUA3X185/ / S TC9 EEMUA3X240/ / TC10 EEMUA3X300/ / S TC11 FIXED WIRING AND MAINS CABLES PVC -15 to +90 C. 12 x overall diameter. Brown, Black, Grey. temperatures below 0 C or above +60 C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES 3300 VOLT (25MM 2 TO 300MM 2 )

34

35 35 FIXED WIRING AND MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH

36 36 FIXED WIRING AND MAINS CABLES LSZH 6491B (HO7Z-R) LSZH Stranded plain annealed compacted circular copper conductor, low smoke and zero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS A2 NYLON A2 CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER (MM) 6491B1/ / / B2/ / / B / / B / / B / / B / / B / S B / S B / B / B / B / B / B / B / B / B / B / S B / S to +90 C. up to 10mm 2-3 x overall diameter above 25mm 2-6 x overall diameter Standard colours available: 1.5mm 2 & 2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. 4mm 2-630mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +40 C. LOW SMOKE ZERO HALOGEN INSULATED WIRING CABLE 6491B (1.5MM 2 TO 630MM 2 )

37 37 XLPE INSULATED LSZH SHEATHED SURFACE WIRING CABLE TYPE 6181B (1MM 2 TO 35MM 2 ) XLPE INSULATED LSZH SHEATHED WIRING CABLE TYPE 624*B (1MM 2 TO 16MM 2 ) SURFACE WIRING CABLES LSZH 6181B Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed, Ref 6181B. 300/500 volts grade to BS7889. Brown/White or Grey/White. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER REF SIZE (MM) (MM) 6181B / / B1/ / / B2/ / / B / / B / / B / S B / S B / B / to +90 C. up to 10mm 2-3 x overall diameter over 10mm 2-4 x overall diameter temperatures below 0 C or above +40 C. SURFACE WIRING CABLES LSZH 624*B Plain annealed compacted copper conductor, XLPE insulated, one, two or three cores laid flat with an uninsulated circuit protective conductor and (LSZH) sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zero halogen (LSZH). Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC 60332), low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO.OF WEIGHT OVERALL CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER (MM) 6241B1/5BR 1.5 1/ X B1/5BR 1.5 1/ X B1WH 1.0 1/ X B1/5WH 1.5 1/ X B1/5BRBR 1.5 1/ X B2/5WH 2.5 1/ X B4WH 4.0 7/ X B6WH 6.0 7/ X B10WH / X B16WH / X B1WH 1.0 1/ X B1/5WH 1.5 1/ X B2/5WH 2.5 1/ X FIXED WIRING AND MAINS CABLES LSZH -25 to +90 C. Fixed = 3 x diameter temperatures below 0 C or above +40 C.

38 38 FIXED WIRING AND MAINS CABLES LSZH MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) LSF2X1/ / / LSF3X1/ / / LSF4X1/ / S 0.5 LSF5X1/ / S 0.6 LSF7X1/ / S 0.6 LSF12X1/ / LSF19X1/ / LSF27X1/ / LSF37X1/ / LSF48X1/ / LSF2X2/ / S 0.5 LSF3X2/ / S 0.6 LSF4X2/ / S 0.6 LSF5X2/ / LSF7X2/ / LSF12X2/ / LSF19X2/ / LSF27X2/ / LSF37X2/ / LSF48X2/ / LSF2X / S 0.6 LSF3X / S 0.6 LSF4X / LSF5X / LSF7X / LSF12X / LSF19X / LSF27X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / LSF2X / LSF3X / LSF4X / LSF5X / LSF7X / XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -25 to +90 C 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - Up to 6mm 2 - White with Black numbers. 5-10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow. 1.5 & 2.5-2,3,4 core also available in white numbered cores to ESI 09-6 temperatures below 0 C or above +40 C.

39 39 MAINS CABLES LSZH Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / LSF2X / LSF3X / LSF4X / LSF5X / S 1.8 LSF2X / LSF3X / LSF4X / S 1.6 LSF5X / TC9 LSF2X / LSF3X / S 1.6 LSF4X / LSF5X / S TC9 LSF2X / LSF3X / S 1.8 LSF4X / LSF5X / TC11 LSF2X / S 1.8 LSF3X / LSF4X / S TC9 LSF2X / LSF3X / S TC9 LSF4X / TC10 LSF2X / LSF3X / TC10 LSF4X / S TC11 LSF3X / S TC11 LSF4X / TC12 FIXED WIRING AND MAINS CABLES LSZH XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS CABLE (25MM 2 TO 400MM 2 ) -25 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above +40 C.

40 40 FIXED WIRING AND MAINS CABLES LSZH SINGLE CORE NON-ARMOURED MAINS CABLES LSZH Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR STRANDING WEIGHT OVERALL BRASS NYLON SINGLE TREFOIL CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER A2 A2 CLEAT CLEAT (MM) 6181B / B / B / B / B / B / B / B / AC B / S AC B / S AC B / AC B / S AC B / TC9 376AC19-25 to +90 C. 6 x overall diameter. Brown inner/black outer. temperatures below 0 C or above +40 C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE NON-ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )

41 41 SINGLE CORE ARMOURED MAINS CABLES LSZH Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to IEC , IEC , BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CONDUCTOR NO. OF WEIGHT OVERALLGLAND GLAND SINGLE TREFOIL CODE SIZE(MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE CLEAT CLEAT ALI BRASS A2 (MM) (MM) 6941AB / AB / AB / AB / AB / AB / AC AB / S AC AB / S AC AB / AC AB / S 63S AC AB / S AC AB / S 75S TC9 376AC AB / S 75S TC10 376AC22 FIXED WIRING AND MAINS CABLES LSZH - 25 to + 90 C 6 x Overall Diameter Brown inner - Black outer temperatures below 0 C or above +40 C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE ARMOURED MAINS CABLE (50MM 2 TO 1000MM 2 )

42 42 FIXED WIRING AND MAINS CABLES LSZH SCREENED FIXED WIRING AND MAINS CABLES TO BS 8436 Plain annealed stranded copper, XLPE insulated, tinned annealed stranded copper earth wire, bonded aluminium tube applied longitudinally, low smoke and zero halogen (LSZH) outer sheath, to BS EN :1998 and BS EN :2000, UV Stable. 600/1000v to BS8436, White. Acid gas emissions to BS EN , smoke emissions to BS EN and flame retardant to BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL 1 HOLE GLAND CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER CLIP REF (MM) REF FSX2X1WH 1.0 7/ RCHL34 20SA2 FSX3X1WH 1.0 7/ RCHL37 20SA2 FSX4X1WH 1.0 7/ RCHL37 20A2 FSX2X1/5WH 1.5 7/ RCHL37 20A2 FSX3X1/5WH 1.5 7/ RCHL40 20A2 FSX4X1/5WH 1.5 7/ RCHL43 20A2 FSX2X2/5WH 2.5 7/ RCHL43 20A2 FSX3X2/5WH 2.5 7/ RCHL43 20A2 FSX4X2/5WH 2.5 7/ RCHL47 20A2 FSX2X4WH 4 7/ RCHL43 20A2 FSX3X4WH 4 7/ RCHL51 25A2 FSX4X4WH 4 7/ RCHL54 25A2 FSX2X6WH 6 7/ RCHL51 25A2 FSX3X6WH 6 7/ RCHL54 25A2 FSX4X6WH 6 7/ RCHL59 25A2 FSX2X10WH 10 7/ RCHL63 25A2 Minimum installation temperature: -10 C. Maximum continuous conductors operating temperature: +90 C. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. *Solid cores available on request. Different sheath and core colours available on request. 10mm 2 and 16mm 2 available on request Also available in 300/500 volt rating. MECHANICALLY PROTECTED WIRING CABLE

43 43 FIXED WIRING AND MAINS CABLES 11000V, 22000V, AND 33000V FIXED WIRING AND MAINS CABLES

44 44 FIXED WIRING AND MAINS CABLES SINGLE CORE ARMOURED MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, copper tape screen, PVC bedding, aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE / AC04 EPKT 17B1XI / AC05 EPKT 17B1XI / AC06 EPKT 17C1XI / AC07 EPKT 17C1XI / AC08 EPKT 17C1XI / AC09 EPKT 17C1XI / S AC11 EPKT 17C1XI / S AC12 EPKT 17D1XI / S AC14 EPKT 17D1XI / AC17 EPKT 17E1XI / S TC9 376AC19 EPKT 17E1XI SINGLE CORE (50MM 2 TO 630MM 2 ) AND 3 CORE (25MM 2 TO 400MM 2 ) XLPE INSULATED MEDIUM VOLTAGE MAINS CABLES VOLT up to 90 C. 12 x overall diameter. Brown. temperatures below 0 C or above +60 C. 3 CORE MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 11KV XLPE3X25RD 25 7/2/ EPKT 17A3XIH2 11KV XLPE3X35RD 35 19/1/ EPKT 17B3XIH2 11KV XLPE3X50RD 50 19/1/ S TC9 EPKT 17B3XIH2 11KV XLPE3X70RD 70 19/2/ S TC9 EPKT 17B3XIH2 11KV XLPE3X95RD 95 19/2/ TC10 EPKT 17C3XIH2 11KV XLPE3X120RD /2/ S TC11 EPKT 17C3XIH2 11KV XLPE3X150RD /2/ S TC11 EPKT 17C3XIH2 11KV XLPE3X185RD /2/ TC12 EPKT 17C3XIH2 11KV XLPE3X240RD /2/ TC14 EPKT 17C3XIH2 11KV XLPE3X300RD /2/ TC14 EPKT 1D3XIH2 11KV XLPE3X400RD /2/ TC15 EPKT 17D3XIH2 up to 90 C. 12 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C or above +60 C.

45 45 3 CORE MAINS CABLES PVC 11000V Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding (extruded), galvanised steel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622 and IEC Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 10115RD 95 19/ TC10 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / TC12 EPKT 17C3XIH RD / TC14 EPKT 17C3XIH RD / TC15 EPKT 17D3XIH2 up to 90 C. 13 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C or above +60 C. FIXED WIRING AND MAINS CABLES XLPE INSULATED MEDIUM VOLTAGE MAINS CABLE VOLT (95MM 2 TO 300MM 2 )

46 46 FIXED WIRING AND MAINS CABLES TRIPLEX CABLES 11000V Solid or stranded aluminium conductor, XLPE insulated, copper wire screen (35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR CONDUCTOR NOMINAL NO. OF WEIGHT DIAMETER CODE SIZE (MM 2 ) TYPE CONDUCTOR CORES KG/KM IN TRIPLEX DIAMETER FORMATION 11KVTRIP3X70AL 70 SOLID KVTRIP3X70AL 70 STRANDED KVTRIP3X95AL 95 SOLID KVTRIP3X95AL 95 STRANDED KVTRIP3X185AL 185 SOLID KVTRIP3X185AL 185 STRANDED KVTRIP3X300AL SOLID KVTRIP3X300AL STRANDED to +90 C. 15 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C. 3 CORE UTILITY CABLE TRIPLEX FORMATION XLPE INSULATED MEDIUM VOLTAGE CABLE VOLT (70MM 2 TO 300MM 2 )

47 47 PAPER INSULATED MAINS CABLES PVC 11000V COPPER CONDUCTOR Plain annealed copper conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION (MM) REFERENCE PILC3X25RD 25 7/ EPKT 17A3MIH2 PILC3X35RD 35 19/ EPKT 17B3MIH2 PILC3X50RD 50 19/ EPKT 17B3MIH2 PILC3X70RD 70 19/ EPKT 17B3MIH2 PILC3X95RD 95 19/ TC9 EPKT 17C3MIH2 PILC3X120RD / TC9 EPKT 17C3MIH2 PILC3X150RD / TC10 EPKT 17C3MIH2 PILC3X185RD / TC10 EPKT 17C3MIH2 PILC3X240RD / TC11 EPKT 17C3MIH2 PILC3X300RD / TC12 EPKT 17D3MIH2 PILC3X400RD / TC14 EPKT 17D3MIH2 FIXED WIRING AND MAINS CABLES PAPER INSULATED MEDIUM VOLTAGE MAINS CABLE VOLT (25MM 2 TO 400MM 2 ) up to 65 C. 13 x overall diameter. White printed numbers on insulating papers. temperatures below 0 C or above +60 C. ALUMINIUM CONDUCTOR Plain aluminium stranded conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION (MM) REFERENCE 10100RD 95 19/ TC9 EPKT 17C3MIH RD / TC11 EPKT 17C3MIH RD / TC12 EPKT 17D3MIH2 up to 65 C. 13 x overall diameter. White printed numbers on insulating papers. temperatures below 0 C or above +60 C.

48 48 FIXED WIRING AND MAINS CABLES SINGLE CORE (50MM 2 TO 630MM 2 ) AND 3 CORE (25MM 2 TO 400MM 2 ) XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLES VOLT SINGLE CORE ARMOURED MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductor, XLPE insulated, semi-conducting tape insulated, copper tape screen, low smoke and zero halogen (LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). Due to poor U.V resistant qualities, red outer sheath cables are not recomended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE / AC04 EPKT 17B1XI / AC05 EPKT 17B1XI / AC06 EPKT 17C1XI / AC07 EPKT 17C1XI / AC08 EPKT 17C1XI / AC09 EPKT 17C1XI / S AC11 EPKT 17C1XI / S AC12 EPKT 17D1XI / S AC14 EPKT 17D1XI X AC17 EPKT 17E1XI X S TC9 376AC19 EPKT 17E1XI up to 90 C. 15 x overall diameter. Brown. temperatures below 0 C or above +40 C. 3 CORE MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). Due to poor U.V resistant qualities red outer sheath cables are not recomended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 10302RD 35 19/ TC9 EPKT 17B3XIH RD 50 19/ S TC9 EPKT 17B3XIH RD 70 19/ S TC9 EPKT 17B3XIH RD 95 19/ TC10 EPKT 17C3XIH RD / S TC11 EPKT 17C3XIH RD / TC11 EPKT 17C3XIH RD / TC12 EPKT 17C3XIH RD / TC14 EPKT 17C3XIH RD / TC14 EPKT 17D3XIH RD / TC15 - up to 90 C. 12 x overall diameter. Brown, Black, Grey tapes. temperatures below 0 C or above +40 C.

49 49 SINGLE CORE AND 3 CORE MAINS CABLES 22KV AND 33KV Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(lszh) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red /22000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL SIZE (MM) CORES (KG/KM) DIAMETER 22KVXLPE3X95RD / to + 90 C temperatures below 0* C or above +40* C. 12 x overall diameter Brown, Black, Grey tapes. FIXED WIRING AND MAINS CABLES Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(lszh) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red /33000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 33KVLSF3X95RD / KVLSF3X185RD / to + 90 C 12 x overall diameter Brown, Black, Grey tapes. temperatures below 0 C or above +40 C. 3 CORE XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLE VOLT (95MM 2 ) AND VOLT (95MM 2 / 185MM 2 )

50

51 51 FIXED WIRING AND MAINS CABLES 33000V - SERVICE AND WINDFARM FIXED WIRING AND MAINS CABLES

52 52 FIXED WIRING AND MAINS CABLES SINGLE CORE MAINS CABLE MDPE 33000V WINDFARM CABLE Round stranded compacted aluminium conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath volts grade to BS7870, IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL SIZE (MM) CORES (KG/KM) DIAMETER 33KV1X70AL / KV1X95AL / KV1X120AL / KV1X150AL / KV1X185AL / KV1X240AL / KV1X300AL / KV1X400AL / KV1X500AL / KV1X630AL / Rated voltage Uo/U 19/33 Kv Max operating voltage 36 kv Test voltage 75 kv Partial discharge level with voltage 2Uo Kv max. 5pC Max. perm conductor temperature 90*C Max. perm operating temperature 130*C Short circuit temperature 250*C Minimum bending radius 12 x overall diameter SINGLE CORE VOLT RATED WINDFARM CABLE ALUMINIUM CONDUCTOR (70MM TO 630MM)

53 53 SINGLE CORE MAINS CABLE MDPE 33000V SERVICE CABLE Round stranded compacted copper conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath volts grade to BS7870, IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 33KVCU1X70BK / KVCU1X95BK / KVCU1X120BK / KVCU1X150BK / KVCU1X185BK / KVCU1X240BK / KVCU1X300BK / KVCU1X400BK / KVCU1X500BK / KVCU1X630BK / FIXED WIRING AND MAINS CABLES Rated voltage Uo/U 19/33 Kv Max operating voltage 36 kv Test voltage 75 kv Partial discharge level with voltage 2Uo Kv max. 5pC Max. perm conductor temperature 90*C Max. perm operating temperature 130*C Short circuit temperature 250*C Minimum bending radius 12 x overall diameter SINGLE CORE VOLT RATED SERVICE CABLE COPPER CONDUCTOR (70MM TO 630MM)

54

55 55 FIREPROOF CABLES FIREPROOF CABLES

56 56 FIREPROOF CABLES FIREPROOF CABLES - MINERAL INSULATED Solid plain annealed copper conductors, magnesium oxide insulated, solid copper sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options: (a) Light Duty = 500 volts grade Heavy Duty = 1000 volts grade (b) Outer sheath finishes, bare copper, PVC or LSZH (c) Outer sheath colours. Orange, Red, White or Black. SIZE BARE SHEATHED OVERALL OVERALL GLAND SINGLE HOLE CLIP NOMINAL REF. KG/KM KG/KM DIAMETER DIAMETER FOR USE REFERENCE STD DRUM BARE SHEATHED WITH RPS BARE SHEATHED LTHS (MTS) (MM) (MM) SEALS 2L L L L L L L L L L L L H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H PVC sheath -20 to +70 C. LSF sheath -20 to +80C. 6 x overall diameter. temperatures below 0 C. MINERAL INSULATED CABLE (1.0MM 2 TO 240MM 2 )

57 57 STANDARD FIRE ALARM AND SECURITY WIRING CABLES Plain annealed copper conductor, silicon rubber insulated aluminium/polyester tape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH) outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387. Flame retardant to BS5839-1:2003 and IEC CAT CWZ, BS Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC 60332). FIREPROOF CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF (MM) (MM) FP2X / E FP3X / E FP4X / E FP7X / E FP12X / E FP2X1/ / E FP3X1/ / E FP4X1/ / E FP7X1/ / E FP12X1/ / E FP19X1/ / E FP2X2/ / E FP3X2/ / E FP4X2/ / E FP7X2/ / E FP12X2/ / E FP19X2/ / E FP2X / E FP3X / E FP4X / E E = Bare earth conductor. -10 to +80 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 7 core and above - White with Black numbers. temperatures below 0 C or above +40 C. FIRE RESISTANT FIRE ALARM & SECURITY CABLE STANDARD (1.0MM 2 TO 4MM 2 )

58 58 FIREPROOF CABLES ENHANCED FIRE ALARM AND SECURITY WIRING CABLES Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced aluminium/polyester tape screen, tinned annealed copper earth wire, enhanced low smoke zero halogen outer sheath. Red or white. Manufactured to meet the Enhanced standard of BS A2:2008 Clause 26.2e Enhanced and also the requirements of BS8434-2: minutes and BS EN Class PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause 11 CWZ, halogen emissions to bs en :1999 and low smoke standard BS EN :2005. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF (MM) (MM) ENH2X1/ / E ENH3X1/ / E ENH4X1/ / E ENH2X2/ / E ENH3X2/ / E ENH4X2/ / E ENH2x / E ENH3x / E ENH4x / E E = Bare earth conductor. -40 to +90 C. 6 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above +40 C. FIRE RESISTANT FIRE ALARM & SECURITY CABLE ENHANCED (1.5MM 2 TO 4MM 2 )

59 59 FIREPROOF CABLES - SINGLES Plain annealed copper conductor, mica fire resistant tape, low smoke zero halogen (LSZH) insulation. 600/1000 volts grade. Fire resistant to IEC 331 and BS6387, CWZ when tested in steel conduit. Manufactured to meet the following standards - acid gas emission to BS EN 50267, flame retardant to BS EN and smoke emission to BS7211. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 6491F1/ / F2/ / F / F / F / F / FIREPROOF CABLES - 40 to + 90 C 8 x Overall Diameter Standard colours available: Brown, Blue, Grey, Black, Green/Yellow. temperatures below 0 C or above 40 C. FIRE RESISTANT SINGLE CORE CABLES (1.5MM 2 TO 16MM 2 )

60 60 FIREPROOF CABLES FIREPROOF MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts. Fire resistant to IEC 331 & BS7846 / BS6387 & CWZ. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 6942F1/ / / F1/ / / F1/ / S F1/ / S /12F1/ / /19F1/ / /27F1/ / /37F1/ / F2/ / S F2/ / S F2/ / S F2/ / /12F2/ / /19F2/ / /27F2/ / /37F2/ / F4 4 7/ S F4 4 7/ S F4 4 7/ F4 4 7/ F4 4 7/ F6 6 7/ F6 6 7/ F6 6 7/ F6 6 7/ F / F / F / F / F / F / F / F / FIRE RESISTANT POWER AND CONTROL CABLE (1.5MM 2 TO 16MM 2 ) -40 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above 4mm 2 and 6mm 2 - White with Black numbers. 5 core - 10mm 2 and 16mm 2 - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C.

61 61 FIREPROOF MAINS CABLES LSZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade. Fire resistant to BS6387/7846 & CWZ. Acid gas emission to BS EN (IEC60754), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN 50265, BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) FP2X / FP3X / FP4X / FP5X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / FP2X / FP3X / FP4X / S 1.8 FP2X / FP3X / S 1.8 FP4X / FP2X / S 1.8 FP3X / FP4X / TC9 FP2X / FP3X / TC9 FP4X / S TC10 FP2X / TC9 FP3X / S TC9 FP4X / TC11 FP2X / S TC9 FP3X / TC10 FP4X / S TC12 FP3X / S TC11 FP4X / TC14 FIREPROOF CABLES -40 to +90 C. 8 x overall diameter. 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER CABLE (25MM 2 TO 400MM 2 )

62 62 FIREPROOF CABLES FIREPROOF MAINS AND CONTROL CABLES LSZH - ENHANCED Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero low smoke zero halogen (LSZH) outer sheath.black. 600/100 grade volts. Manufactured to meet the following standards - circuit integrity: BS minutes, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC , BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / to + 90 C 8 x Overall Diameter 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (4MM 2 TO 16MM 2 )

63 63 FIREPROOF MAINS CABLES LSZH - ENHANCED Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero low smoke zero halogen (LSZH) outer sheath.black. 600/100 grade volts. Manufactured to meet the following standards - circuit integrity: BS minutes, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC , BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN FIREPROOF CABLES CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLE CODE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZE (MM) CLEAT FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / FPE4X / FPE2X / FPE3X / S 1.8 FPE4X / FPE2X / S 1.6 FPE3X / S 1.8 FPE4X / TC9 FPE2X / S 1.8 FPE3X / FPE4X / S TC9 FPE2X / FPE3X / S TC9 FPE4X / TC10 FPE2X / TC9 FPE3X / TC10 FPE4X / S TC11 FPE2X / S TC9 FPE3X / TC10 FPE4X / TC12 FPE3X / S TC12 FPE4X / TC14-40 to + 90 C 8 x Overall Diameter 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. temperatures below 0 C or above 40 C. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (25MM 2 TO 400MM 2 )

64

65 65 FLEXIBLE CABLES FLEXIBLE CABLES

66 66 FLEXIBLE CABLES PVC INSULATED FLEXIBLE CORDS 218*Y - 318*Y Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath. Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F). Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) *2182Y/ / /16 *2182Y/ / /16 *2183Y/ / /16 *2183Y/ / / Y/ / / Y/ / / Y/ / / Y/ / / Y/ / / Y/ / S 3182Y / / Y / / Y / S 3185Y / S 3182Y1/ / / Y1/ / S 3184Y1/ / S 3185Y1/ / Y2/ / S 3183Y2/ / S 3184Y2/ / Y2/ / Fixed - -5 to +60 C. Flexing - +5 to +60 C. Fixed 2 x overall diameter. Flexing 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308 four core is available in two alternative core identification methods. temperatures below 0 C. *Light flexible cords 300/300 volts grade PVC INSULATED FLEXIBLE CORDS TYPE 218*Y & 318*Y (0.5MM 2 TO 2.5MM 2 )

67 67 PVC INSULATED FLEXIBLE CORDS 309*Y Plain annealed flexible copper conductors heat resisting PVC outer sheath. White 300/500 volts grade to BS6141. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3092Y/ / / Y/ / / Y/ / / Y/ / S 3093Y/ / S 3094Y/ / S 3095Y/ / S 3092Y / S 3093Y / S 3094Y / S 3092Y1/ / S 3093Y1/ / S 3094Y1/ / Y2/ / S 3093Y2/ / Y2/ / FLEXIBLE CABLES PVC INSULATED FLEXIBLE CORDS TYPE 309*Y (0.5MM 2 TO 2.5MM 2 ) AND ARTIC GRADE (1.5MM 2 TO 4MM 2 ) Fixed - -5 to +90 C. Flexing - +5 to +90 C. Fixed - 2 x overall diameter. Flexing - 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow. temperatures below 0 C. ARCTIC GRADE FLEXIBLE CORDS Plain annealed flexible copper conductors, low temperature PVC insulation, low temperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table 44 and BS6500. Flame propagation to BS EN CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3183AG1/ / S 3184AG1/ / S 3183AG2/ / S 3184AG2/ / AG4 4 56/ AG6 6 76/ Flexing - 40 to + 70 C 6 x overall diameter. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow.

68 68 FLEXIBLE CABLES ZERO HALOGEN FLEXIBLE CORDS (HO5 ZIZI-F) Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 volts grade (Generally to BS6500) Harmonised code HO5 ZIZI-F. Acid gas emission to BS EN (IEC ), smoke emission to BS EN (IEC 61034) and flame propagation to BS EN (IEC ). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3182B/ / / B/ / / B/ / / B/ / S 3182B / / B / / B / S 3185B / S 3182B1/ / / B1/ / S 3184B1/ / S 3185B1/ / B2/ / S 3183B2/ / S 3184B2/ / B2/ / to +70 c Fixed 4x overall diameter Flexing 6x overall diameter 2 core - Brown, Blue. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308, four core is available in two alternative core identification methods. temperatures below 0 C. LOW SMOKE ZERO HALOGEN FLEXIBLE CORDS TYPE 318*B (0.75MM 2 TO 2.5MM 2 )

69 69 TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X/ / /16 YY3X/ / /16 YY4X/ / /16 YY5X/ / /16 YY7X/ / /16 YY12X/ / S YY18X/ / YY25X/ / YY34X/ / YY50X/ / YY65X/ / YY2X / /16 YY3X / /16 YY4X / /16 YY5X / /16 YY7X / S YY12X / S YY18X / YY25X / YY34X / YY41X / YY50X / YY65X / YY2X1/ / /16 YY3X1/ / /16 YY4X1/ / /16 YY5X1/ / S YY7X1/ / S YY8X1/ / YY10X1/ / YY12X1/ / YY18X1/ / YY25X1/ / YY34X1/ / YY50X1/ / YY65X1/ / FLEXIBLE CABLES -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE YY (0.75MM 2 TO 1.5MM 2 )

70 70 FLEXIBLE CABLES TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X2/ / /16 YY3X2/ / S YY4X2/ / S YY5X2/ / S YY7X2/ / S YY8X2/ / YY12X2/ / YY18X2/ / YY25X2/ / YY34X2/ / YY3X / S YY4X / S YY5X / YY7X / YY3X / YY4X / YY5X / YY7X / YY3X / YY4X / YY5X / YY3X / YY4X / YY5X / YY3X / YY4X / YY5X / YY4X / YY5X / YY4X / S -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE YY (2.5MM 2 TO 50MM 2 )

71 71 TYPE SY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) SY2X/ / /16 SY3X/ / /16 SY4X/ / /16 SY5X/ / /16 SY7X/ / /16 SY12X/ / S SY18X/ / S SY25X/ / S SY34X/ / SY2X / /16 SY3X / /16 SY4X / /16 SY5X / /16 SY7X / /16 SY12X / S SY18X / SY25X / SY34X / SY50X / SY2X1/ / /16 SY3X1/ / /16 SY4X1/ / /16 SY5X1/ / /16 SY7X1/ / /16 SY12X1/ / S SY18X1/ / SY25X1/ / SY34X1/ / SY50X1/ / SY2X2/ / /16 SY3X2/ / /16 SY4X2/ / /16 SY5X2/ / S SY7X2/ / S SY12X2/ / SY18X2/ / SY25X2/ / SY34X2/ / FLEXIBLE CABLES -5 to +70 C. Static - 10 x overall diameter. Flexing - 20 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE SY (0.75MM 2 TO 2.5MM 2 )

72 72 FLEXIBLE CABLES TYPE SY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) SY3X / S SY4X / S SY5X / SY7X / SY3X / S SY4X / S SY5X / SY7X / SY3X / SY4X / SY5X / SY3X / SY4X / SY5X / SY4X / SY5X / SY4X / SY5X / SY4X / SY4X / S SY4X / to +70 C. Static - 10 x overall diameter. Flexing - 20 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE SY (4MM 2 TO 95MM 2 )

73 73 TYPE CY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) BRASS A2 CY2X/ / /16 CY3X/ / /16 CY4X/ / /16 CY5X/ / /16 CY7X/ / /16 CY2X/ / /16 CY3X/ / /16 CY4X/ / /16 CY5X/ / /16 CY7X/ / /16 CY12X/ / S CY18X/ / CY25X/ / CY2X / /16 CY3X / /16 CY4X / /16 CY5X / /16 CY7X / /16 CY12X / S CY18X / CY25X / CY34X / CY2X1/ / /16 CY3X1/ / /16 CY4X1/ / /16 CY5X1/ / S CY7X1/ / CY12X1/ / CY18X1/ / CY25X1/ / CY34X1/ / CY42X1/ / CY2X2/ / /16 CY3X2/ / /16 CY4X2/ / S CY5X2/ / S CY7X2/ / S CY12X2/ / CY2X / S CY3X / S CY4X / S CY5X / S CY4X / S CY4X / CY4X / FLEXIBLE CABLES PVC INSULATED BRAID SCREENED FLEXIBLE POWER AND CONTROL CABLE TYPE CY (0.75MM 2 TO 16MM 2 ) Static to +80 C. Flexing - -5 to +70 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods.

74 74 FLEXIBLE CABLES TYPE YY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) YY2X/75LSF / /16 YY3X/75LSF / /16 YY4X/75LSF / /16 YY5X/75LSF / /16 YY2X1LSF / /16 YY3X1LSF / /16 YY4X1LSF / /16 YY5X1LSF / /16 YY2X1/5LSF / /16 YY3X1/5LSF / /16 YY4X1/5LSF / /16 YY5X1/5LSF / S YY7X1/5LSF / S YY12X1/5LSF / YY18X1/5LSF / YY25X1/5LSF / YY34X1/5LSF / YY2X2/5LSF / /16 YY3X2/5LSF / S YY4X2/5LSF / S YY5X2/5LSF / S YY3X4LSF / S YY4X4LSF / S YY5X4LSF / YY3X6LSF / YY4X6LSF / YY5X6LSF / YY3X10LSF / YY4X10LSF / YY5X10LSF / YY3X16LSF / YY4X16LSF / YY3X25LSF / to +70 C Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter 2 Core - Black with white numbers 3 Core and above Black with white numbers plus Green/Yellow temperatures below -5 C. TYPE CY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen (LSZH) outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) CY2X/75LSF / /16 CY3X/75LSF / /16 CY4X/75LSF / /16 CY5X/75LSF / /16 CY2X1/5LSF / /16 CY3X1/5LSF / /16 CY4X1/5LSF / /16 CY5X1/5LSF / /16 LSZH SHEATHED POWER AND CONTROL CABLE TYPE YY (0.75MM 2 TO 25MM 2 ) AND TYPE CY (0.75MM 2 TO 1.5MM 2 ) -5 to 70 C Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter 2 Core - Black with White numbers 3 Core and above Black with White numbers plus Green/Yellow temperatures below -5 C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow or Brown, Black, Grey, Green/Yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. As per Cenelec HD 308, four core cable is available in 2 alternative identification methods.

75 75 TRI-RATED EQUIPMENT WIRES Plain annealed stranded circular copper conductors, circular high temperature PVC outer sheath. UL & CSA approved also to BS /1000 volts grade. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) TRI0/ / TRI/ / TRI / TRI1/ / /16 TRI2/ / /16 TRI / /16 TRI / /16 TRI / /16 TRI / S TRI / S TRI / TRI / TRI / TRI / TRI / BI / BI / BI / BI / S BI / FLEXIBLE CABLES -30 to +105 C. temperatures below 0 C. Standard colours available: 0.5mm 2-2.5mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White, Orange, Pink, Violet. 4.0mm 2-16mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White. 25.0mm 2-120mm 2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow. 150mm 2 - Black, Green/Yellow. 185mm 2-400mm 2 - Black. TRI-RATED SWITCHGEAR AND CONTROL PANEL WIRE (0.5MM 2 TO 400MM 2 )

76 76 FLEXIBLE CABLES SINGLE CORE PVC FLEXIBLE MAINS CABLES Plain annealed flexible copper conductor, PVC insulated PVC sheathed, 450/750 volts, generally to BS6004 & IEC Flame propogation to BS4066 PT1 & IEC332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6381Y / / Y / S 6381Y / S 6381Y / Y / Y / Y / Y / Y / Y / Y / Y / Y / Y / S -15 to +70 C. Up to 50mm 3 x overall diameter. Over 70mm 5 x overall diameter. Standard core colours available: Black, grey, blue, brown, green/yellow. temperatures below 0 C. PVC INSULATED PVC SHEATHED FLEXIBLE CABLE (6MM 2 TO 400MM 2 )

77 B/6701B LSZH FLEXIBLE SINGLE CORES Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer sheath to BS mm rated at 300/500 volts grade, harmonised code HO5Z-K. 1.5mm to 240mm rated at 450/750 volts grade, harmonised code HO7Z-K. Fire resistant to BS EN :2001 (formerly BS4066:PT1). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL CODE SIZE (MM) CORES (KG/KM) DIAMETER 2491B / B1/ / B2/ / B / B / B / B / B / B / B / B / B / B / B / B / B / FLEXIBLE CABLES - 15 to + 90 C up to 35mm2-3 x Overall Diameter 50mm2 and above - 4 x Overall Diameter Standard colours available: 1.5mm to 6mm - Black, Blue, Brown, Grey, Orange, White, Red, Yellow, Green/Yellow. 10mm2-240mm2 - Black, Blue, Brown, Grey. LOW SMOKE ZERO HALOGEN SHEATHED FLEXIBLE CABLE (1.5MM 2 TO 240MM 2 )

78 78 FLEXIBLE CABLES FLEXIBLE MAINS AND CONTROL CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500. Black or White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 3182TQ/ / TQ/ / TQ/ / TQ / TQ / TQ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / TQ1/ / /12TQ1/ / /16TQ1/ / /20TQ1/ / /27TQ1/ / /37TQ1/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / /12TQ2/ / /16TQ2/ / /20TQ2/ / /27TQ2/ / /37TQ2/ / to +90 C. Fixed - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HOFR SHEATHED FLEXIBLE POWER AND CONTROL CABLE (0.75MM 2 TO 2.5MM 2 ) Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

79 79 FLEXIBLE MAINS CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. FLEXIBLE CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381TQ / TQ / TQ / TQ / TQ / TQ / /12TQ / TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ6 6 84/ TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. Fixed - 6 x overall diameter. Flexing - 7 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HEAVY DUTY HOFR SHEATHED FLEXIBLE MAINS CABLE (4MM 2 TO 16MM 2 ) Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

80 80 FLEXIBLE CABLES FLEXIBLE MAINS CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN (BS EN ). Harmonised code H07BN4-F. CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. Fixed - 5 x overall diameter. Flexing - 7 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below -25 C. EPR INSULATED HOFR SHEATHED POWER AND CONTROL CABLE (25MM 2 TO 630MM 2 )

81 81 FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 3182P / P / P / P1/ / P1/ / P1/ / P1/ / P1/ / /12P1/ / P2/ / P2/ / P2/ / P2/ / P2/ / /12P2/ / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / FLEXIBLE CABLES -25 to +85 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C. RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (1MM 2 TO 50MM 2 )

82 82 FLEXIBLE CABLES FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN CCC CONDUCTOR STRANDING NO. OF WEIGHT MEAN OVERALLDIAMETER CODE SIZE (MM 2 ) (MM) CORES KG/KM (MM) LOWER LIMIT UPPER LIMIT 6381P / P / P / P / P / P / P / P / P / P / P / P / P / P / P / to +85 C. Static - 6 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C. RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (70MM 2 TO 630MM 2 )

83 83 TOUGH RUBBER SHEATH FLEXIBLE CORDS Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, tough rubber sheath. Black. 300/500 volts grade to BS6500 and BS7919. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3182/ / / / / / / / / / / / / / / / / S 31831/ / S 31841/ / S 31851/ / S 31822/ / S 31832/ / S 31842/ / / / FLEXIBLE CABLES EPR INSULATED TOUGH RUBBER SHEATH (0.75MM 2 TO 2.5MM 2 ) EPR INSULATED BRAIDED SCREEN FLEXIBLE MAINS AND CONTROL CABLE (1.0MM 2 TO 16MM 2 ) +60 C. 6 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. BRAIDED TOUGH RUBBER SHEATH FLEXIBLE CORDS Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where applicable). Black. Flame propogation to BS 4066 PT1 and IEC 332 PT1. Heat and oil resistant and flame retardant (HOFR). CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 3802TQ / / TQ / / TQ / / TQ1/ / / TQ1/ / S 3804TQ1/ / S 3802TQ2/ / S 3803TQ2/ / TQ2/ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / to +90 C. 8 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Blue, Green/Yellow. temperatures below 0 C.

84 84 FLEXIBLE CABLES COIL END LEAD FLEXIBLE MAINS CABLES Flexible tinned annealed copper conductors composite ethylene propylene rubber chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4. A. 300/500 volts grade E. 3800/6600 volts grade C. 600/1000 volts grade F. 6350/11000 volts grade D. 1900/3300 volts grade CONDUCTOR RADIAL THICKNESS OF INSULATION VOLTAGE CATEGORY SIZE STRANDING MAX APPROX. A C D E F CCC CODE (MM 2 ) (MM 2 ) DIA. OF DIA. OF (MM) (MM) (MM) (MM) (MM) WIRES COND. (MM) (MM) / / / TYPE 4 1/ / TYPE 4 2/ / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / TYPE / MINIMUM OVERALL DIAMETER WEIGHT VOLTAGE CATEGORY VOLTAGE CATEGORY CCC CODE A C D E F A C D E F (MM) (MM) (MM) (MM) (MM) KG/KM KG/KM KG/KM KG/KM KG/KM TYPE 4 1/ TYPE 4 2/ TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE EPR INSULATED FLEXIBLE COIL LEAD (0.5MM 2 TO 400MM 2 ) -20 to +90 C. 6 x overall diameter. temperatures below -25 C.

85 85 WELDING CABLES 0361TQ Tinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flame retardant to BS EN (BS EN ). CCC CONDUCTOR STRANDING WEIGHT OUTSIDE GLAND CODE SIZE (MM 2 ) (MM) KG/KM DIAMETER SIZE (MM) (MM) 0361TQ16OR / S 0361TQ25OR / TQ35OR / TQ50OR / TQ70OR / TQ95OR / TQ120OR / TQ185OR / FLEXIBLE CABLES -20 to +85 C. 8 x overall diameter. EPR INSULATED FLEXIBLE WELDING CABLE TYPE 0361TQ (16MM 2 TO 185MM 2 )

86 86 FLEXIBLE CABLES RUBBER FLATFORM CABLES Flexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath (TPR). Black. 600/1000 volts grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL MAX CURRENT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIMENSIONS RATINGS (MM) (AMPS) FLAT4X1/5R / X5 22 FLAT12X1/5R / X5 12 FLAT4X2/5R / X6 30 FLAT7X2/5R / X7 20 FLAT12X2/5R / X6 20 FLAT4X4R 4 56/ X7 40 FLAT4X6R 6 84/ X7 52 FLAT4X10R 10 80/ X9 70 FLAT4X16R / X10 95 FLAT4X25R / X FLAT4X35R / X FLAT4X50R / X FLAT4X70R / X to +85 C. 10 x overall diameter. 4 core - Black, Grey, Brown, Green/Yellow. 7 and 12 core - Black cores with White numbers and one Green/Yellow. temperatures below 0 C. PVC FLATFORM CABLES Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black. 450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL MAX CURRENT CODE SIZE (MM 2 ) (MM) CORES KG/KM DIMENSIONS RATINGS (MM) (AMPS) FLAT4X1/5V / X5 20 FLAT12X1/5V / X5 11 FLAT4X2/5V / X6 27 FLAT12X2/5V / X6 16 FLAT4X4V 4 56/ X7 36 FLAT4X6V 6 84/ X7 48 FLAT4X10V 10 80/ X9 63 FLAT4X16V / X11 85 FLAT4X25V / X FLAT4X35V / X FLAT4X50V / X FLAT4X70V / X FLAT4X95V / X RUBBER INSULATED FLAT CABLE (1.5MM 2 TO 70MM 2 ) AND PVC INSULATED FLAT CABLE (1.5MM 2 TO 95MM 2 ) -25 to +70 C. 10 x overall diameter. 4 core - Black, Grey, Brown, Green/Yellow. 12 core - Black cores with white numbers and one Green/Yellow. temperatures below 0 C.

87 87 SILICON FLEXIBLE CABLES SIHF Flexible tinned annealed copper conductors, silicone insulated, silicone outer sheath. 300/500 volts grade to VDE 0250 PT816. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) BIHF2X/ / /16 BIHF3X/ / /16 BIHF4X/ / /16 BIHF5X/ / S BIHF7X/ / S BIHF2X / /16 BIHF3X / /16 BIHF4X / S BIHF5X / S BIHF7X / S BIHF2X1/ / /16 BIHF3X1/ / /16 BIHF4X1/ / S BIHF5X1/ / S BIHF7X1/ / S BIHF2X2/ / S BIHF3X2/ / S BIHF4X2/ / S BIHF5X2/ / S BIHF7X2/ / FLEXIBLE CABLES -60 to +180 C. Fixed - 5 x overall diameter. Flexing - 15 x overall diameter. 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core and above - Grey, Black, Brown, Blue, Green/Yellow 6 core and above - Black with White numbers plus Green/Yellow. temperatures below 0 C. SILICONE INSULATED FLEXIBLE CABLE (0.75MM 2 TO 2.5MM 2 )

88

89 89 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

90 90 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - BS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation, Blue or Black to BS5308 Part 1 Type 1. Flame propagation to BS4066 PT1, BS EN and IEC PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black to BS5308 Part 2 Type1. Flame propagation to BS4066 PT1, BS EN and IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE BRASS PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / / / / / / S / TRIPLE / / / / / / / / / / S / TRIPLE / / / / S / / / N/A N/A 1.5 7/ S N/A N/A 1.5 7/ S / TRIPLE S BS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) sheath, Blue or Black, to BS5308 Part 1, Type 1 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / / / / INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH COLLECTIVE SCREEN (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.

91 91 INSTRUMENTATION AND CONTROL CABLES - BS5308 BS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC BS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN and IEC CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE BRASS PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / S / / / / / * / / / / / S / S / / / / S / / INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES BS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar tape screened. Complete with 0.5mm 2 drain wire, collective aluminium/mylar tape screen complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) outer sheath, Black or Blue, generally to BS5308 Part 1, Type 1 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER A2 (MM) GLAND / / / / INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.

92 92 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - BS5308 BS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. BS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / S / / / / / S / TRIPLE / / / / S / / / / / S / TRIPLE S / S / S / / / / S / S TC / TRIPLE S / S / / / / / TRIPLE S 0.6 BS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to BS5308 Part 1, Type 2 LSZH. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / S / / / / S / S / / / INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH COLLECTIVE SCREEN (0.5MM 2 TO 2.5MM 2 ) -20 to +65 C. 6 x overall diameter.. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.

93 93 INSTRUMENTATION AND CONTROL CABLES - BS5308 BS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. BS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / S / TC / / / / / S / S TC / / / / S / TC / TC10 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES BS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to BS5308. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / / / / S 1.8 INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREEN (0.5MM 2 TO 1.5MM 2 ) -20 to +65 C. 6 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C.

94 94 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - BS5308 BS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. BS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm 2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / / / S / S TC / / / / / / S / S TC / / / / / S / / TC10-20 to +63 C. 5 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH COLLECTIVE SCREEN (0.75MM 2 TO 1.5MM 2 )

95 95 INSTRUMENTATION AND CONTROL CABLES - BS5308 BS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen, complete with 0.5mm 2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. BS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC and IEC 332-3C. CCC CODE CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND CLEAT PT1 PT2 SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) (MM) / / / / S / S / S TC10 N/A N/A 1.0 1/ N/A N/A 1.0 1/ N/A N/A 1.0 1/ N/A N/A 1.0 1/ S 1.8 N/A N/A 1.0 1/ TC9 N/A N/A 1.0 1/ TC / / / S / / S TC / S TC12 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES -20 to +65 C. 15 x overall diameter. Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. temperatures below 0 C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.75MM 2 TO 1.5MM 2 )

96 96 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES BS5308 PART 1 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK GREEN 27 RED YELLOW 3 BLUE GREEN 28 ORANGE YELLOW 4 BLACK BROWN 29 BLACK GREY 5 BLUE BROWN 30 BLUE GREY 6 GREEN BROWN 31 GREEN GREY 7 BLACK WHITE 32 BROWN GREY 8 BLUE WHITE 33 WHITE GREY 9 GREEN WHITE 34 RED GREY 10 BROWN WHITE 35 ORANGE GREY 11 BLACK RED 36 YELLOW GREY 12 BLUE RED 37 BLACK VIOLET 13 GREEN RED 38 BLUE VIOLET 14 BROWN RED 39 GREEN VIOLET 15 WHITE RED 40 BROWN VIOLET 16 BLACK ORANGE 41 WHITE VIOLET 17 BLUE ORANGE 42 RED VIOLET 18 GREEN ORANGE 43 ORANGE VIOLET 19 BROWN ORANGE 44 YELLOW VIOLET 20 WHITE ORANGE 45 GREY VIOLET 21 RED ORANGE 46 BLACK TURQUOISE 22 BLACK YELLOW 47 BLUE TURQUOISE 23 BLUE YELLOW 48 GREEN TURQUOISE 24 GREEN YELLOW 49 BROWN TURQUOISE 25 BROWN YELLOW 50 WHITE TURQUOISE For individual screened pairs, identification will be Black/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue, Black, Green. BS5308 PART 1 CORE IDENTIFICATION

97 97 INSTRUMENTATION AND CONTROL CABLES BS5308 PART 2 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 WHITE BLUE 26 RED/BLUE BLUE 2 WHITE ORANGE 27 RED/BLUE ORANGE 3 WHITE GREEN 28 RED/BLUE GREEN 4 WHITE BROWN 29 RED/BLUE BROWN 5 WHITE GREY 30 RED/BLUE GREY 6 RED BLUE 31 BLUE/BLACK BLUE 7 RED ORANGE 32 BLUE/BLACK ORANGE 8 RED GREEN 33 BLUE/BLACK GREEN 9 RED BROWN 34 BLUE/BLACK BROWN 10 RED GREY 35 BLUE/BLACK GREY 11 BLACK BLUE 36 YELLOW/BLUE BLUE 12 BLACK ORANGE 37 YELLOW/BLUE ORANGE 13 BLACK GREEN 38 YELLOW/BLUE GREEN 14 BLACK BROWN 39 YELLOW/BLUE BROWN 15 BLACK GREY 40 YELLOW/BLUE GREY 16 YELLOW BLUE 41 WHITE/ORANGE BLUE 17 YELLOW ORANGE 42 WHITE/ORANGE ORANGE 18 YELLOW GREEN 43 WHITE/ORANGE GREEN 19 YELLOW BROWN 44 WHITE/ORANGE BROWN 20 YELLOW GREY 45 WHITE/ORANGE GREY 21 WHITE/BLUE BLUE 46 ORANGE/RED BLUE 22 WHITE/BLUE ORANGE 47 ORANGE/RED ORANGE 23 WHITE/BLUE GREEN 48 ORANGE/RED GREEN 24 WHITE/BLUE BROWN 49 ORANGE/RED BROWN 25 WHITE/BLUE GREY 50 ORANGE/RED GREY For individual screened pairs, identification will be White/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Blue, Green, Orange, Brown. Single triple will be Blue, White, Orange. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES BS5308 PART 2 CORE IDENTIFICATION

98 98 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD Plain annealed flexible copper conductors, PVC bedding, tinned annealed copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) BSC1342C / S 0.6 BSC1343C / S 0.6 BSC1344C / S 0.6 BSC1347C / S 0.7 BSC13412C / BSC13419C / BSC13427C / BSC13437C / to +70 C. 6 x overall diameter. CORE IDENTIFICATION: temperatures below 0 C. NO. OF COLOUR CORES 2 BROWN BLUE 3 BROWN BLUE GREEN/YLW 4 BROWN GREY GREEN/YLW BLACK 7 RED BLUE GREEN YELLOW WHITE BLACK BROWN 12 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY 19 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW 27 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK 37 RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK GRN/ORANGE GREEN/GREY BROWN/YLW BRN/WHITE BRN/BLACK BROWN/GREY VIOLET/YLW VIOLET/BLACK VIOLET/WHT RED/GREY INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 134 (0.75MM 2 )

99 99 INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLE CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE CLEAT (MM) (MM) BSC1431P / / BSC1432P / S 0.5 BSC1435P / BSC14310P / BSC14320P / BSC14330P / BSC14350P / to +70 C. 6 x overall diameter. temperatures below 0 C. CORE IDENTIFICATION ACCORDING TO EATS 09-6 SECTION 3 PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK ORANGE 27 WHITE VIOLET 3 BLACK GREEN 28 BLUE RED 4 BLACK BROWN 29 BLUE YELLOW 5 BLACK GREY 30 BLUE VIOLET 6 BLUE WHITE 31 GREEN RED 7 BLUE ORANGE 32 GREEN YELLOW 8 BLUE GREEN 33 GREEN VIOLET 9 BLUE BROWN 34 RED GREY 10 BLUE GREY 35 RED ORANGE 11 ORANGE WHITE 36 RED YELLOW 12 ORANGE GREEN 37 RED BROWN 13 ORANGE BROWN 38 RED VIOLET 14 ORANGE GREY 39 GREY YELLOW 15 GREEN WHITE 40 GREY VIOLET 16 GREEN BROWN 41 ORANGE YELLOW 17 GREEN GREY 42 ORANGE VIOLET 18 BROWN WHITE 43 YELLOW BROWN 19 BROWN GREY 44 YELLOW VIOLET 20 GREY WHITE 45 BROWN VIOLET 21 BLACK WHITE 46 TURQUOISE BLACK 22 BLACK RED 47 TURQUOISE BLUE 23 BLACK YELLOW 48 TURQUOISE RED 24 BLACK VIOLET 49 TURQUOISE ORANGE 25 WHITE RED 50 TURQUOISE YELLOW INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 143 (0.75MM 2 )

100 100 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INTERNAL TELEPHONE CABLES TYPE CW1308 Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC sheathed. To BPO CW(M) Sheath colour: White. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC STRANDING No. OF WEIGHT OVERALL GLAND CODE (MM 2 ) PAIRS KGS/KM DIAMETER SIZE (MM) (MM) / / / / / / / / / / / E S / S / S / E / E / E / E / E / E / E / E / E / E E. denotes earth core. -20 to +70 C. CORE IDENTIFICATION: 5 x overall diameter. temperatures below 0 C. PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 WHITE/BLUE BLUE/WHITE 16 YELLOW/BLUE BLUE/YELLOW 2 WHITE/ORANGE ORANGE/WHITE 17 YELLOW/ORANGE ORANGE/YELLOW 3 WHITE/GREEN GREEN/WHITE 18 YELLOW/GREEN GREEN/YELLOW 4 WHITE/BROWN BROWN/WHITE 19 YELLOW/BROWN BROWN/YELLOW 5 WHITE/GREY GREY/WHITE 20 YELLOW/GREY GREY/YELLOW 6 RED/BLUE BLUE/RED 21 VIOLET/BLUE BLUE/VIOLET 7 RED/ORANGE ORANGE/RED 22 VIOLET/ORANGE ORANGE/VIOLET 8 RED/GREEN GREEN/RED 23 VIOLET/GREEN GREEN/VIOLET 9 RED/BROWN BROWN/RED 24 VIOLET/BROWN BROWN/VIOLET 10 RED/GREY GREY/RED 25 VIOLET/GREY GREY/VIOLET 11 BLACK/BLUE BLUE/BLACK 26 PINK/BLUE BLUE/PINK 12 BLACK/ORANGE ORANGE/BLACK 27 PINK/ORANGE ORANGE/PINK 13 BLACK/GREEN GREEN/BLACK 28 PINK/GREEN GREEN/PINK 14 BLACK/BROWN BROWN/BLACK 29 PINK/BROWN BROWN/PINK 15 BLACK/GREY GREY/BLACK 30 PINK/GREY GREY/PINK INTERNAL TELEPHONE CABLE TYPE CW1308

101 101 COMMUNICATION CABLES - TELEPHONE EATS 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.6 * / / S / / / / / * 2 pair laid up in quad formation. -20 to +70 C. See colour chart on page 104. temperatures below 0 C. Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.9 * S / S / / / / / / / / / / S 1.8 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.9 * / / S / / / / / / / / S 1.8 PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD * 2 pair laid up in quad formation. -20 to +70 C. 6 x overall diameter. See colour chart on page 104. temperatures below 0 C.

102 102 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD COMMUNICATION CABLES - TELEPHONE EATS 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 * S / S / / / / / / / / S 1.8 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6: Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 * S / S / / / / / / / / S 1.8 Solid tinned annealed copper, polyethylene insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to EATS 09-6: Issue 6 Section 4.5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 * / / S / / / / S 1.8 Solid tinned, annealed copper conductors, polyethylene insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm 2 drain, wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to EATS 09-6: Issue 6 Section 4.5. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE /0.8 * S / S / / * 2 pair laid up in quad formation. -20 to +70 C. 8 x overall diameter. See colour chart on page 104. temperatures below 0 C or 40 C.

103 103 COMMUNICATION CABLES - TELEPHONE EATS 09-6 Solid plain annealed copper conductor, polyethylene insulated, petroleum jelly filled, polyetheylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To EATS 09-6 issue 6 section 3 table 2 - induced voltage between the pairs up to 15kv. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE SIZE (MM) PAIRS DIAMETER SIZE (MM) CLEAT / / / S to +70* 8 x Overall Diameter 7 pair: centre - red & yellow. outer layer - black & violet, orange & grey*, green & brown, orange & blue*, green & brown, orange & white*. 19 pair: centre - centre and first layer as 7 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. 37 pair: centre, first and second layer as 19 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. * denotes carrier pairs. temperatures below 0* C or above 40* C. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PE INSULATED MULTIPAIR ARMOURED CABLE TO EATS STANDARD

104 104 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES EATS 09-6 SECTION 3.6 AND 4.5 CORE IDENTIFICATION CORE IDENTIFICATION ACCORDING TO EATS 3.6 AND 4.5 SECTION 3.6 COLOUR CODING PAIR A B PAIR A B NUMBER WIRE WIRE NUMBER WIRE WIRE 1 BLACK BLUE 26 WHITE YELLOW 2 BLACK ORANGE 27 WHITE VIOLET 3 BLACK GREEN 28 BLUE RED 4 BLACK BROWN 29 BLUE YELLOW 5 BLACK GREY 30 BLUE VIOLET 6 BLUE WHITE 31 GREEN RED 7 BLUE ORANGE 32 GREEN YELLOW 8 BLUE GREEN 33 GREEN VIOLET 9 BLUE BROWN 34 RED GREY 10 BLUE GREY 35 RED ORANGE 11 ORANGE WHITE 36 RED YELLOW 12 ORANGE GREEN 37 RED BROWN 13 ORANGE BROWN 38 RED VIOLET 14 ORANGE GREY 39 GREY YELLOW 15 GREEN WHITE 40 GREY VIOLET 16 GREEN BROWN 41 ORANGE YELLOW 17 GREEN GREY 42 ORANGE VIOLET 18 BROWN WHITE 43 YELLOW BROWN 19 BROWN GREY 44 YELLOW VIOLET 20 GREY WHITE 45 BROWN VIOLET 21 BLACK WHITE 46 TURQUOISE BLACK 22 BLACK RED 47 TURQUOISE BLUE 23 BLACK YELLOW 48 TURQUOISE RED 24 BLACK VIOLET 49 TURQUOISE ORANGE 25 WHITE RED 50 TURQUOISE YELLOW All two pair cables are in quad formation and colour coded in rotation - Blue, Orange, Green, Brown. SECTION 4.5 COLOUR CODING PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY 11 BLACK BLUE 12 BLACK ORANGE 13 BLACK GREEN 14 BLACK BROWN 15 BLACK GREY 16 YELLOW BLUE 17 YELLOW ORANGE 18 YELLOW GREEN 19 YELLOW BROWN 20 YELLOW GREY Each unit is lapped with coloured tape for identification as follows UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT10 If sub-units are used, binders for corresponding sub-units shall be the same colour. BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET All two pair cables are in quad formation and colour coded in rotation - White, Red, Blue, Orange. For 30 pair cables the formation will be 3 X 10 pair units numbered - 1, 2 and 3. For 40 pair cables the formation will be 2 X 20 pair units numbered - 1 and 2. For 50 pair cables the formation will be 5 X 10 pair units numbered - 1, 2 3, 4 and 5.

105 105 PETROLEUM JELLY FILLED TELEMETRY CABLE TO CW1128, CW1128/1198 AND BS3573 COMMUNICATION CABLES PETROLEUM JELLY FILLED Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE (MM) CORES KG/KM DIAMETER SIZE SIZE (MM) / / / / / / / Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour, PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric construction). Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE / S / S / / / Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, collective aluminium/mylar tape screen, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To BS3573 and CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEAT CODE SIZE (MM 2 ) (MM) PAIRS KG/KM DIAMETER SIZE SIZE (MM) (MM) SINGLE / / / / COLOUR SCHEME FOR BS UNIT CONSTRUCTION PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY Cables may be manufactured using 5- pair sub-units coloured as 1-5 and 6-10 UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT 10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET If sub-units are used binders for corresponding sub-units shall be the same colour.

106 106 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES DEFENCE STANDARD CONTROL CABLES Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts grade. To Ministry of Defence Standard DEF (Part 4 for 7/0.2 conductors, Part 5 for 16/0.2 conductors). Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM 2 ) CORES KG/KM DIAMETER SIZE (MM) (MM) 722C / C / C / C / C / C / C / C / C / C / C / C / C / C / C / C / C /0.20 * C / C / C / C / C / C / Tinned annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulation, non-hygroscopic binder tape, tinned annealed copper wire braid screen, low smoke and zero halogen (LSZH) outer sheath. Black. 440 volt grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM 2 ) CORES KG/KM DIAMETER SIZE (MM) (MM) LSF1622C / LSF1623C / LSF1624C / LSF1626C / LSF16212C / LSF16218C / LSF16225C / * Laid up in a pair configuration. -55 to +70 C. 6 x overall diameter. See colour chart on page 107. temperatures below 0 C. DEFENCE STANDARD SCREENED MULTICORE CABLE C TYPE

107 107 DEFENCE STANDARD CONTROL CABLES COLOUR CODING CORE COLOUR NUMBER 1 RED 2 BLUE 3 GREEN 4 YELLOW 5 WHITE 6 BLACK 7 BROWN 8 VIOLET 9 ORANGE 10 PINK 11 TURQUOISE 12 GREY 13 RED/BLUE 14 GREEN/RED 15 YELLOW/RED 16 WHITE/RED 17 RED/BLACK 18 YELLOW/BLUE 19 YELLOW/BLUE 20 WHITE/BLUE 21 BLUE/BLACK 22 ORANGE/BLUE 23 GREEN/BLUE 24 GREY/BLUE 25 YELLOW/GREEN 26 WHITE/GREEN 27 GREEN/BLACK 28 ORANGE/GREEN 29 GREY/GREEN 30 YELLOW/BROWN 31 WHITE/BROWN 32 BROWN/BLACK 33 GREY/BROWN 34 YELLOW/VIOLET 35 VIOLET/BLACK 35 VIOLET/BLACK 36 WHITE/VIOLET INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Where 2 colours are shown the core is striped e.g. Red/Blue - the core is striped Red with Blue. DEFENCE STANDARD PARTS 4 & 5 CORE IDENTIFICATION

108 108 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES COMPENSATING AND THERMOCOUPLE CABLES NON-ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF SIZE STRANDING OVERALL GLAND JX KCB KX TX PAIRS (MM 2 ) (MM) DIAMETER SIZE CCC CCC CCC CCC (MM) (MM) CODE CODE CODE CODE (WAS VX) / / / / / / / to +105 C. 5 x overall diameter. See colour chart on page 93. temperatures below 0 C. ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm 2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF SIZE STRANDING OVERALL GLAND JX KCB KX TX PAIRS (MM 2 ) (MM) DIAMETER SIZE CCC CCC CCC CCC (MM) (MM) CODE CODE CODE CODE (WAS VX) / / / / / / / to +105 C. 6 x overall diameter. See colour chart on page 109. temperatures below 0 C. PVC INSULATED COLLECTIVE SCREENED THERMOCOUPLE EXTENSION AND COMPENSATING CABLE (0.75MM 2 )

109 109 COMPENSATING AND THERMOCOUPLE CABLES COLOUR CODING EX JX KX NX TX UX VX CODE BRITISH BS1843: 1952 AMERICAN ANSI INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES GERMAN DIN RC/SC KCB IEC COLOUR CODING OF THERMOCOUPLE EXTENSION AND COMPENSATING CABLE IEC INTRINSICALLY SAFE

110 110 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE TRAFFIC SIGNALLING CABLES TRAFFIC CONTROL CABLE WITH ARMOUR Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath, colour orange, generally to BS6346/87 CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) TRAF4X / S TRAF8X / S TRAF12X / TRAF16X / TRAF20X / TRAF4X1/ / S TRAF8X1/ / TRAF12X1/ / TRAF16X1/ / TRAF20X1/ / TRAF8X1ESWA* 1.0 1/ LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour orange, generally to BS6346/87, 600/1000v grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL BRASS CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER A2 (MM) GLAND TRAF8X1NA 1.0 1/ TRAF12X1NA 1.0 1/ TRAF8X1E* 1.0 1/ to +70 C. 4 core - Red, Blue, Yellow, Green. 8 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange. * includes additional 6mm2 integral earth conductor 12 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue Violet. 16 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red. 20 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, Violet/Red, Orange/Red, Green/Red, Blue/White. temperatures below 0 C.

111 111 TRAFFIC SIGNALLING CABLES LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene outer sheath, colour orange, 600/1000v grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP2X1/ / (1pr) S LOOP4X1/ / (2pr) S LOOP2X2/ / (1pr) S LOOP4X2/ / (2pr) S -15 to +70 C. 6 x overall diameter. TRAFFIC CONTROL CABLE ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, polyethylene outer sheath. Generally to BS6346/87. Outer sheath colour: Orange. 600/1000 volts grade. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP2X1/5SWA 1.5 1/ (1pr) S LOOP4X1/5SWA 1.5 1/ (2pr) S LOOP2X2/5SWA 2.5 1/ (1pr) S LOOP4X2/5SWA 2.5 1/ (2pr) to +70 C. 6 x overall diameter. 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. temperatures below 0 C. 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. temperatures below 0 C. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES LOOP DETECTOR CABLE Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR), polychloroprene sheathed (PCP), 600/100v generally to BS BS6195, sheath colour black. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) LOOP1/ / S LOOP2/ / S -30 to +85 C. 6 x overall diameter. temperatures below -25 C. PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE

112

113 113 DATA AND COAXIAL CABLES DATA AND COAXIAL CABLES

114 114 DATA AND COAXIAL CABLES DATA, COAXIAL AND LAN CABLES BELDEN EQUIVALENTS: CD8138/SWA/LSF 8 PAIR 28AWG COLLECTIVE SCREEN PLUS STEEL WIRE ARMOUR,LSF SHEATH. CD PAIR 16AWG UNSCREENED, PVC SHEATH. CD8471/LSF 1 PAIR 16AWG UNSCREENED, PVC SHEATH. CD PAIR 16AWG COLLECTIVE SCREEN, PVC SHEATH. CD8719/LSF 1 PAIR 16AWG COLLECTIVE SCREEN, LSF SHEATH. CD8723/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN,LSF SHEATH. CD8723/SWA/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN PLUS STEEL WIRE ARMOUR, LSF SHEATH. CD8760/LSF 1 PAIR 18AWG COLLECTIVE SCREEN. LSF SHEATH. CD PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. CD8761/LSF 1 PAIR 22AWG INDIVIDUAL SCREEN, LSF SHEATH. CD PAIR 20AWG COLLECTIVE SCREEN, PVC SHEATH. CD8762/LSF 1 PAIR 20AWG COLLECTIVE SCREEN, LSF SHEATH. CD PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. CD PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. CD PAIR 22AWG COLLECTIVE SCREEN, PVC SHEATH. CD9463 TWIN AXIAL 20AWG, PVC SHEATH. CD9463/SWA/PVC TWIN AXIAL 20AWG PLUS STEEL WIRE ARMOUR, PVC SHEATH. CD PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. CD9501/LSF 1 PAIR 24AWG COLLECTIVE SCREEN, LSF SHEATH. CD PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. CD9502/LSF 2 PAIR 24AWG COLLECTIVE SCREEN, LSF SHEATH. CD PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. CD PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. CD PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. CD PAIR 24AWG INDIVIDUAL SCREEN, PVC SHEATH. CD PAIR 18AWG INDIVIDUAL SCREEN, PVC SHEATH. COAXIAL CABLES CT OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. CT100LSOH 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. WF100BK 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. WC100BK 75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PVC SHEATH. WF125BR 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. CT OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. CT125LSOH 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. CT125RBS 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH. CT OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. CT167RBS 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, DIRECT BURIAL SHEATH. RG11AU 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. RG11SWA 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PVC SHEATH. RG58 50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. RG59BU 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. RG59LSOH 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH. RG59SWA 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PVC SHEATH. RG62AU 93 OHM BRAIDED SCREEN, PE TUBE AND THREAD, PVC SHEATH. RG62SWA 93 OHM BRAIDED SCREEN, PE TUBE AND THREAD PLUS SWA, PVC SHEATH. URM OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. URM OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. URM70 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. UTP CABLES 4UTPCAT5E ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. 4UTPCAT5ELSF ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSF VIOLET SHEATH. 4FTPCAT5E ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. 4FTPCAT5ELSF ENHANCED SCREENED 4 PAIR CAT 5 E, LSF VIOLET SHEATH. 4FTPCAT5ESWA ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH. 4UTPCAT6 UNSCREENED 4 PAIR CAT 6, GREY PVC SHEATH. 4UTPCAT6LSF UNSCREENED 4 PAIR CAT 6, GREY LSOH SHEATH 4UTPCAT5EDUCT ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE. Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

115 115 RAILWAY CABLES RAILWAY CABLES

116 116 RAILWAY CABLES RAILWAY CABLES SIGNALING (0.75MM 2-95MM 2 ) RAILWAY SIGNALLING CABLES Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS for types B1, LSZH insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath for types A1 & B1, LSZH sheath for types A2 & A3. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) A11X/75BR 6/ A1 Brown / N/A A11X/75RD 6/ A1 Red / N/A A11X/75OR 6/ A1 Orange / N/A A11X/75GY 6/ A1 Grey / N/A A11X/75VIR 6/ A1 Violet / N/A A11X/75BK 6/ A1 Black / N/A A11X115BK 6/ A1 Black / N/A A21X/75 6/ A / N/A A21X115 6/ A / /16 A32X/75 6/ A / /16 A34X/75 6/ A / S A36X/75 6/ A / S A310X/75 6/ A / A314X/75 6/ A / A336X/75 6/ A / A348X/75 6/ A / B11X2/5 6/ B / /16 B11X10 6/ B1 10 7/ S B11X35 6/ B / B22X1/5 6/ B / S B22X2/5 6/ B / B22X10 6/ B2 10 7/ B22X16 6/ B2 16 7/ B22X35 6/ B / B22X70 6/ B / B22X95 6/ B / B24X/75 6/ B / S B24X1/5 6/ B / B24X2/5 6/ B / B24X10 - B2 10 7/ B27X/75 6/ B / B27X1/5 6/ B / B27X2/5 6/ B / B210X/75 6/ B / B210X1/5 6/ B / B210X2/5 6/ B / B212X/75 6/ B / B26PX/75 6/ B /0.37 6pr B212X1/5 6/ B / B212X2/5 6/ B / B219X/75 6/ B / B219X1/5 6/ B / B219X2/5 6/ B / B227X/75 6/ B / B227X1/5 6/ B / B227X2/5 6/ B / B237X/75 6/ B / B237X1/5 6/ B / B237X2/5 6/ B / B248X/75 6/ B / B248X1/5 6/ B / B248X2/5 6/ B / S -25 to +85 C. 8 x overall diameter. Black with white numbers.

117 117 RAILWAY SIGNALLING CABLES Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS Heavy duty PCP RS2 sheath for types C1 + C2, LSZH sheath for types D1, D2, E1+E2. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) C11X2/5 6/ C / C22X2/5 6/ C / C24X2/5 6/ C / C27X2/5 6/ C / C210X2/5 6/ C / C212X2/5 6/ C / C216X2/5 6/ C / D11X/75 6/ D / /16 D11X1/5 6/ D / /16 D11X2/5 6/ D / /16 D11X10 6/ D1 10 7/ S D11X35 6/ D / D22X1/5 6/ D / S D22X2/5 6/ D / D22X10 6/ D2 10 7/ D22X35 6/ D / D227X/75 6/ D / D227X1/5 6/ D / D227X2/5 - D / D237X/75 6/ D / D237X1/5 6/ D / D237X2/5 - D / D248X/75 6/ D / D248X1/5 6/ D / D248X2/5 6/ D / S E11X2/5 6/ E / E22X2/5 6/ E / E24X2/5 6/ E / E27X2/5 6/ E / E210X2/5 6/ E / E212X2/5 6/ E / RAILWAY CABLES -25 to +85 C. 8 x overall diameter. Black with white numbers. RAILWAY CABLES SIGNALING (0.75MM 2-35MM 2 )

118 118 RAILWAY CABLES RAILWAY TRAIN PROTECTION WARNING CABLES Flexible tinned copper conductors to BS6360, EPR insulated to BS , separate drain wire,single aluminium tape screen (polyester backed). Black Heavy duty PCP RS2 sheath to BS7655 for type C3, LSZH sheath for type E3. Manufactured to Network Rail specification NR/PS/SIG/OOOO5 (formerly RT/E/PS/00005). CCC RAIL RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE TYPE SIZE CORES (KG/KM) DIAMETER SIZE (MM) C3TPWS 6/ C3TPWS /0.25 1PR E3TPWS 6/ E3TPWS /0.25 1PR to +85 C. 8 x overall diameter. RAILWAY CABLES TRAIN PROTECTION WARNING POINT HEATER RAILWAY POINT HEATER CABLES Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045). CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) 3184PH1/5 6/ / PH1/5 6/ / PH2/ / PH4 6/ / PH / PH / PH / S -30 to +70 C. 4 core - Yellow, Yellow, Blue, Blue. 8 core - Yellow, Yellow, Blue, Blue, Brown, Brown, Black, Black.

119 119 RAILWAY AXLE COUNTING CABLES Solid plain annealed copper conductors, polyethylene insulation, petroleum jelly filled, polyethylene outer sheath. Manufactured to Network Rail specification RT/E/PS/0031. CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE PAIRS (KG/KM) DIAMETER SIZE (MM 2 ) F1D0902 6/ / F1D0910 6/ / F1D0912 6/ / F1D0919 6/ / F1D0924 6/ / S F1D1402 6/ / F1D1410 6/ / F1D1412 6/ / S F1D1419 6/ / S F1D1424 6/ / S RAILWAY CABLES RAILWAY CABLES AXLE COUNTING CABLES AND DATALINK PAIR NO A WIRE B WIRE PAIR NO A WIRE B WIRE 1 WHITE BLUE 13 YELLOW GREEN 2 WHITE ORANGE 14 YELLOW BROWN 3 WHITE GREEN 15 YELLOW GREY 4 WHITE BROWN 16 VIOLET BLUE 5 WHITE GREY 17 VIOLET ORANGE 6 RED BLUE 18 VIOLET GREEN 7 RED ORANGE 19 VIOLET BROWN 8 RED GREEN 20 VIOLET GREY 9 RED BROWN 21 TURQUOISE BLUE 10 RED GREY 22 TURQUOISE ORANGE 11 YELLOW BLUE 23 TURQUOISE GREEN 12 YELLOW ORANGE 24 TURQUOISE BROWN Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black. -40 to +70 C. 15 x overall diameter RAILWAY DATALINK CABLE Solid copper conductor, polythylene insulation, aluminium/polyethylene laminated moisture barrier, polyethylene sheath black or blue. To BR1932. CCC RAIL STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE CORES (KG/KM) DIAMETER SIZE DATALINK2X1/27 6/ / DATALINK2X1/27BU 6/ / DATALINK2X1/27LSF 6/ / PE sheath -40 to + 70 C LSZH sheath -10 to + 50 C 15 x overall diameter Blue, Red.

120 120 RAILWAY CABLES RAILWAY AXLE COUNTING CABLE NON ARMOURED Solid tinned annealed copper conductors, polyethylene insulation (type 03 to BS6234), petroleum jelly filled (XPS and XQS types only), glass fibre weave, aluminium/polymer laminate tape, polyetheylene sheath (type 03C to BS6234) or LSZH. Manufactured to Network Rail specification RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG CCC RAIL CABLE CONDUCTOR STANDING NO. OF WEIGHT OVERALL CODE CODE TYPE SIZE (MM) PAIRS (KG/KM) DIAMETER - 6/ XPS / XQS / / XPS / XQS / / XPS / XQS / / XPS / XQS / / XPS / XQS / / XPS / XQS 1.5 1/ / XPS / XQS 1.5 1/ / XPS / XQS 1.5 1/ / XPS / XQS 1.5 1/ / XPS / XQS 1.5 1/ to + 85 C 7.5 x overall diameter Table 6 core colours: PAIR CORE COLOURS 1 White Blue 2 White Orange 3 White Green 4 White Brown 5 White Grey 6 Red Blue 7 Red Orange 8 Red Green 9 Red Brown 10 Red Grey 11 Yellow Blue 12 Yellow Orange 13 Yellow Green 14 Yellow Brown 15 Yellow Grey 16 Violet Blue 17 Violet Orange 18 Violet Green 19 Violet Brown 20 Violet Grey 21 Turquoise Blue 22 Turquoise Orange 23 Turquoise Green 24 Turquoise Brown Table 7 layer make-up: PAIR NOS. IN EACH LAYER NO. OF PAIRS CENTRE 1ST LAYER 2 1 & & 2 3 -> > 3 4 -> > & 2 3 -> 10 RAILWAY AXLE COUNTING CABLE NON ARMOURED

121 121 RAILWAY COPPER TRACKSIDE COMMUNICATION CABLES Solid plain annealed copper conductors to BS6360, polytheylene insulation, petroleum jelly filled, corrugated steel armour, polytheylene outer sheath. Manufactured to Network Rail specification NR/PS/TEL/00015 (formerly RT/E/PS/00015). CCC RAIL CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE PAIRS (KG/KM) DIAMETER SIZE (MM 2 ) / / / / / / / / / / RAILWAY CABLES -25 to +85 C. 2 PAIR (laid up in quad formation) 10 x overall diameter. PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY 20 PAIR (laid up in 4x5 pair) SUB-UNIT (CODE A) PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY SUB-UNIT (CODE B) PAIR A B NUMBER WIRE WIRE 1 RED BLUE 2 RED ORANGE 3 RED GREEN 4 RED BROWN 5 RED GREY Each unit is lapped with coloured tape for identification as follows: UNIT UNIT COLOUR OF NUMBER CODE BINDINGS 1 A BLUE 2 B BLUE 3 C ORANGE 4 D ORANGE 30 PAIR (laid up in 3x10 pair) 50 PAIR (laid up in 5x10 pair) Each unit is lapped with coloured tape for identification as follows: COPPER TRACKSIDE CABLE SUB-UNIT (CODE A) PAIR A B NUMBER WIRE WIRE 1 WHITE BLUE 2 WHITE ORANGE 3 WHITE GREEN 4 WHITE BROWN 5 WHITE GREY 6 RED BLUE 7 RED ORANGE 8 RED GREEN 9 RED BROWN 10 RED GREY UNIT COLOUR OF BINDINGS NUMBER 1 BLUE 2 ORANGE 3 GREEN 4 BROWN 5 GREY

122 122 RAILWAY CABLES RAILWAY POWER AND TRACK FEEDER CABLES POWER CABLES Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath, Black to BR880 06/ /1000 volts grade to BS CCC RAIL CONDUCTOR NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) SAC2X16NA 6/ SAC2X25NA 6/ SAC2X35NA 6/ SAC2X50NA 6/ SAC2X70NA 6/ SAC2X95NA 6/ SAC4X70NA 6/ C. 8 x overall diameter. 2 core - Brown, Blue. 4 core - Blue, Brown, Black, Grey. RAILWAY CABLES POWER & TRACK FEEDER TRACK FEEDER CABLES Uncompacted circular stranded aluminium to BS6360 or uncompacted circular stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black. Manufactured to Network Rail specification NR/PS/ELP/21101 (formerly RT/E/S/21101). CCC RAIL POLARITY CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE CODE SIZE CORES (KG/KM) DIAMETER SIZE (MM 2 ) TRACK150 6/ NEGATIVE 150 AL 37/ TRACK161 6/ NEGATIVE 161 CU 91/ TRACK240 6/ NEGATIVE 240 AL 61/ TRACK500 6/ POSITIVE 500 AL 61/ TRACK500CU 6/ NEGATIVE 500 CU 91/ TRACK630CU 6/ POSITIVE 630 CU 127/ S TRACK800 6/ NEGATIVE 800 AL 127/ S TRACK1000 6/ POSITIVE 1000 AL 127/ C to +85 C. Aluminium conductor - 10x overall diameter Copper conductor - 8x overall diameter

123 123 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES

124 124 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883 and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6571TQ1/ / / TQ1/ / S 6573TQ1/ / S 6574TQ1/ / S 6575TQ1/ / S 6576TQ1/ / TQ1/ / TQ1/ / /10TQ1/ / /12TQ1/ / /19TQ1/ / /27TQ1/ / /30TQ1/ / /37TQ1/ / TQ2/ / / TQ2/ / S 6573TQ2/ / S 6574TQ2/ / TQ2/ / TQ2/ / TQ2/ / TQ2/ / /10TQ2/ / /12TQ2/ / /19TQ2/ / /27TQ2/ / /30TQ2/ / /37TQ2/ / TQ / / TQ / TQ / TQ / TQ / TQ / TQ / / TQ / TQ / TQ / White with Black numbers. Single cores available in either Black or Green/Yellow outer sheath. temperatures below -15 C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (1.5MM 2 TO 6MM 2 )

125 125 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883 and IEC CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6571TQ / S 6572TQ / TQ / TQ / TQ / S 6572TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / S 6571TQ / TQ / S 6574TQ / TQ / TQ / TQ / S 6571TQ / TQ / S 6571TQ / TQ / TQ / TQ / S 6571TQ / S 6571TQ / TQ / S MARINE AND OFFSHORE CABLES Single core cables are available in Black or Green/Yellow outer sheath. -30 to +85 C. up to 25mm - 4 x overall diameter. above 25mm - 6 x overall diameter. White with Black numbers. temperatures below -15 C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (10MM 2 TO 630MM 2 )

126 126 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883 IEE CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6582TQ1/ / S 6583TQ1/ / S 6584TQ1/ / S 6585TQ1/ / S 6586TQ1/ / TQ1/ / /12TQ1/ / /19TQ1/ / /27TQ1/ / /37TQ1/ / TQ2/ / S 6583TQ2/ / S 6584TQ2/ / TQ2/ / TQ2/ / TQ2/ / /12TQ2/ / /19TQ2/ / /27TQ2/ / /37TQ2/ / TQ / TQ / TQ / TQ / TQ / to +85 C. 6 x overall diameter. White with Black numbers. temperatures below -15 C. EPR INSULATED BRAIDED ARMOUR SHIPWIRING CABLE (1.5MM 2 TO 4MM 2 )

127 127 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6883 & IEE92-3. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6582TQ6 6 7/ TQ6 6 7/ TQ6 6 7/ TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / S 6582TQ / TQ / S 6584TQ / TQ / S 6583TQ / TQ / S 6582TQ / S 6583TQ / S 6584TQ / S 6582TQ / TQ / S 6584TQ / TQ / TQ / S 6583TQ / TQ / TQ / TQ / MARINE AND OFFSHORE CABLES -30 TO +85 C. 6 x overall diameter White with Black numbers. temperatures below -15 C. EPR INSULATED BRAIDED ARMOURED SHIPWIRING CABLE (6MM 2 TO 300MM 2 )

128 128 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding tinned phosphor bronze braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883 & IEE92-3. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CODE SIZE (MM 2 ) (MM) CORES KG/KM DIAMETER SIZE (MM) (MM) 6591TQ6 6 7/ / TQ / S 6591TQ / S 6591TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / TQ / S 6591TQ / S 6591TQ / TQ / to +85 C. 6 x overall diameter. White. temperatures below -15 C. EPR INSULATED SINGLE CORE BRAIDED SHIPWIRING CABLE (6MM 2 TO 630MM 2 )

129 129 INSTALLATION ACCESSORIES INSTALLATION ACCESSORIES

130

131 131 LML LML Products Limited Since its inception in 1968, LML has designed, manufactured and supplied a comprehensive range of copper tube terminals including bespoke specials. With in-house tooling and electroplating facilities, LML will always provide a solution for its quality focused customers in compliance with BS EN ISO 9001:2000 Copper Tube Terminals LML terminals are manufactured from seamless copper tube to BS EN and feature bell mouth entry up to 400mm 2 and chamfered entry from 500mm 2 to 1000mm 2. All terminals and splices (other than parallel splices) are provided with an inspection hole to ensure the conductor is fully inserted before crimping. Internal barrel diameters suit standard cables as defined in BS EN Standard finish is bright electro tin plating to BS EN Other finishes can be provided, e.g. nickel or silver. Terminals are independently tested to comply with BS EN , and are also approved for military use and by London Underground. Crimp Tooling LML Products also supply a large range of manual hydraulic tools for crimping terminals from 1.5mm 2 to 1000mm 2. LML also supplies a range of hydraulic crimping tools with rechargeable battery. Med/High Voltage Crimp Terminals LML Products manufactures a range of copper tube terminals to suit 11kv and 33kv. We also manufacture water blocked splices and terminals.

132

133

134 www. cmp-products.com CMP CMP PRODUCTS SERVICES AND SUPPORT FROM CMP PRODUCTS CMP Products offers a comprehensive training program for the installation of it's products. Whether you just need a video to show you how it's done, require practicaldemonstrations at your premises or indeed you require training on site for large groups, CMP is able to assist. We offer certified training on all of our products with all attendees receiving a training certificate following successfulcompletion of the course to demonstrate competence. CERTIFIED TRAINING AVAILABLE for designers/specifiers for installers for a QA, QC Personnel installation video's available for all products in multiple languages for design engineers to assist with correct product selection to keep up with the latest standards wherever you need it, when you need it ALSO AVAILABLE from CMP Products Breather Drain Plugs Adaptors & Reducers Stopper Plugs Unions Locknuts Serrated Washers Earth Tags Entry Thread Seals Shrouds

135 135 RAXTON LIMITED Raxton products are designed to solve the fundamental difficulties which exist due to the variety of thread forms currently in use within the electrical industry. These thread forms are predominantly Isometric, Imperial, N.P.T., BSP and PG. Problems caused by dissimilar threads can occur in many environments including industrial, EExd, EExe and mining. Raxton conversions are fully approved to meet these requirements, being certified by leading test authorities including BASEEFA, SIRA, ISSEP, KEMA, DET NORSKE VERITAS and Standards Association of Australia. They are marked accordingly. Standard material is brass and readily available alternatives include mild steel, stainless steel and aluminium. Our EExe range is also available in glass filled nylon. ADAPTORS REDUCERS HEXAGON HEAD PLUGS RIGHT ANGLE ADAPTORS MALE TO MALE ADAPTORS UNIONS STOPPING PLUGS EARTH LEAD ADAPTORS THREADED EARTH PLATES NYLON GLANDS SCREWED NIPPLING COUPLERS BUSHES SHROUDS LOCKNUTS/LOCKRINGS EARTH TAGS WASHERS

136 Legrand cable management solutions... LEGRAND CABLE MANAGEMENT

137

138 138 W. J. FURSE & COMPANY LIMITED E-Klips is a division of W J Furse & Co Ltd, a multi-disciplined engineering and marketing company employing nearly 200 people worldwide. We are the largest UK manufacturer of a comprehensive range of industrial fasteners, which are made available to the electrical/mechanical industry. They provide a quick, efficient method of fixing without drilling or bracket making. Our commitment to quality has set industry standards while our new designs bring you all the benefits of E-Klips continuous product development philosophy. Wholly manufactured in the UK, E-Klips fasteners can be found throughout Europe and in many other countries in the world where our unequalled combination of speed and quality is properly appreciated. This combination can give you savings of up to 60% over a complete installation a very significant competitive advantage! E-Klips are available for every type of installation through our established distributor network who are fully supported by our stocks and service. So, if you would like to use the faster fastener, simply specify E-Klips and put your opposition in the shade.

139 139 W. J. FURSE & COMPANY LIMITED As a recognised world leader in the Earthing and Lightning Protection Industry, W J Furse has a proven track record spanning over one hundred years. The range complies with the requirements of relevant British and World standards, and our design and manufacturing quality control systems are independently assessed and approved to ISO9001. W J Furse can also offer a level of competitiveness, service and technical support that is the envy of competitors both in the UK and overseas. Our extensive range includes the following: Earth Rods Copperbond, solid copper and stainless steel. Earth Pits Lightweight, high performance plastic and regular duty concrete pits. Fittings Clamps, bonds, clips and accessories in copper and aluminium alloys and plastics suitable for flat tape and solid circular conductor systems. Conductors An extensive range of copper and aluminium conductors available bare and PVC covered. Specialist Products Including weldable and adhesive conductor clips and earth rod seals. Furseweld Process An exothermic welding process with a simple self contained method of forming high quality electrical connections which do not require external power or heat source, making the process completely portable.

140 140 FRAMING AND SUPPORT SYSTEMS AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL

141 141 AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL

142

143 Tel: Fax: Cables & leads Cable management Heating & ventilation Distribution, switchgear & enclosures Lamps Lighting products Security & emergency Site equipment. tools & fixings Wiring accessories MEMBER offering a great deal more

144 Middlesbrough Branch Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: Sales / Admin Fax: Sales / Admin sales@clevelandcable.com Website: Bristol Branch St. Georges Industrial Estate, St. Andrews Road, Avonmouth, Bristol BS11 9HS Tel: Fax: bristol@clevelandcable.com Glasgow Branch 56 Clydesmill Road, Cambuslang Investment Park, Cambuslang, Glasgow G32 8RE Tel: Fax: glasgow@clevelandcable.com Milton Keynes Branch 7 Fitzhamon Court, Wolverton Mill South, Milton Keynes MK12 6LB Tel: Fax: miltonkeynes@clevelandcable.com London Branch Crabtree Manorway South, Belvedere, Kent DA17 6AB Tel: Fax: london@clevelandcable.com Newcastle Branch Fisher Street Industrial Estate, Walker, Newcastle Upon Tyne NE6 4LT Tel: Fax: newcastle@clevelandcable.com Warrington Branch 2 Bishops Court, Calver Road, Winwick Quay, Warrington WA2 8QY Tel: Fax: warrington@clevelandcable.com Bilcourt Electrical Distributors Ltd Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: Fax: sales@bilcourt.co.uk

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN LSOH Wiring Cables Low Voltage (/7 V) LSOH Conduit Wire (HO7ZR) 91B Cable Approvals Cable approved to BS711 Key Applications > Installation in surface mounted or embedded conduits, or similar closed systems

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Building & Infrastructure Cables DELIVERING ENERGY

Building & Infrastructure Cables DELIVERING ENERGY Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an

More information

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables cmi XLPE s PRODUCT CATALOGUE Electric Wire & s Complies to AS/NZ Standard cmi XLPE s www.cmielectrical.com.au A division of CMI Operions Pty Ltd ABN 87 088 279 270 For over 15 years XLPE s has provided

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

Catalogue. Index INDUSTRIAL CABLE

Catalogue. Index INDUSTRIAL CABLE Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

3. Fire Resistant Cables

3. Fire Resistant Cables Fire Resistant Cables The -to-fire is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas.

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas. Aftec is a leading manufacturer of cable glands,cable Connectors and associated accessories, used extensively for power control, lighting and instrumentation cable application in connection with IEC and

More information

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved. PROTEC Screened Wiring Cable Updated to meet new requirements of BS 8436:2011 BASEC approved www.aeicables.co.uk PROTEC CABLES Manufactured and designed to BS 8436 and IS 273 Protec Low Smoke Zero Halogen

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

6491B / H07Z-R / BS EN Cable

6491B / H07Z-R / BS EN Cable 6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume

More information

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

FLEX-O-POWER FLEXIBLE WELDING

FLEX-O-POWER FLEXIBLE WELDING EQUIPMENT cables FLEX-O-POWER FLEXIBLE WELDING & POWER CABLE High conductivity bunched flexible annealed copper conductors, insulated with a soft flexible grade PVC suitable for welding and power purposes.

More information

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data Content Page CONTENTS Page Introduction... 2 Customer Service... 3-4 Specification...5 Construction...6 Application...6 Technical Data...7-14 1.1 Unarmoured Cables with Overall Screened (TYPE 1)...7 1.2

More information

Single Core Cables 51

Single Core Cables 51 Single Core Cables 51 Single Core Cables PVC PVC Single Core Cables H05V-K /H07V-K Conductors: Flexible copper (class 5) Insulation: PVC Standards: HAR CENELEC Fire Performance: Flame retardant to IEC

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

PRODUCT CATALOGUE Volume 4

PRODUCT CATALOGUE Volume 4 PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath. Standard Power Cables Low age (600/1000 V) BS5467 Cable Approvals > Cable approved to BS5467 > Pla annealed copper stranded (Class 2) for ease of handlg Insulation > 90 C -lked XLPE sulation complyg with

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Controlflex Cables Controlflex Cables

Controlflex Cables Controlflex Cables YY Type Cable.............................: CY Type Cable..............................: YCY-JZ Transparent PVC Sheath...............: SY Type Cable.............................:1 YY-LSF Type Cables.........................:1

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison. Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable 0.6/1kV - PVC Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS: 1.IEC60502-1;VDE 0276-603 ;ICEA S-95-658 ;AS/NZS 5000.1; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number cores : One core, two cores,

More information

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication

More information

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

Price List NATIONAL PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four Price List HSN Code : 8544 w.e.f. : 01.06.2018 "NATIONAL" PVC FLEXIBLE CABLE WITH COPPER CONDUCTOR SINGLE CORE 1.1 KV CONFORMING TO IS:694/2010. "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING

More information

CABLES TRADE PRICE LIST

CABLES TRADE PRICE LIST CABLES TRADE PRICE LIST NO. TPR07-3rd September 2009 ENERGY TRADE PRICE LIST TPR07 3rd September 2009 FOR CABLES These cables are sold subject to Prysmian s Standard Conditions of Sale, copies of which

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

CONTENTS. Introduction Customer Service Product Range Specification and Construction...4-6

CONTENTS. Introduction Customer Service Product Range Specification and Construction...4-6 CONTENTS PAGE Introduction... 1 Customer Service...2-3 Product Range... 4 Specification and Construction...4-6 Salient Features of Ducab s Design... 7 Installation and Electrical Data...7-19 XLPE Insulated

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable 0.6/1kV Al-Cu XLPE Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS 1.IEC;VDE ;ICEA;AS/NZS; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number of cores : One core, two cores, three cores, 3+1 cores,

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

Transit Cable Products

Transit Cable Products Bicon Cable Glands Transit Cable Products 2 Janes Court, Cambridge Cambridgeshire CB1 3JJ United Kingdom Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the

More information

PVC Heat Resistant Cables-to BS Y. XLPE Single Core Double Insulated-to BS 7889

PVC Heat Resistant Cables-to BS Y. XLPE Single Core Double Insulated-to BS 7889 Notes ! Content page CABLES SUPPLIED GLOBALLY erence No. Description Har Code P age 622YH, 622LH, 62YH, 62LH, 621YH, 621LH, PVC Single, Twin and Core & Earth cables to BS 600 5 18YAG, 187YAG Artic Cables-to

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. INTRODUCTION : Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. Rubber is still considered the preferred insulation for

More information

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation

More information

Installation Guidelines For BW Gland

Installation Guidelines For BW Gland Installation Guidelines For BW Gland Address: Raychem RPG Pvt. ltd. 1/62, M G Road, Off. Western express highway, Near Bharat Petroleum, Valiv Village, Post Sativali, Vasai (E) 401208, Maharashtra, India.

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for

More information

WIRES & WIRING CABLES

WIRES & WIRING CABLES WIRES & WIRING CBLES CBLES FZE www.markcables.com Index 1) Introduction................ 02 2) CU/PVC Wires 450/750 Volts Round Solid (Class 1) H07V-U......... 04 3) CU/PVC Wires 450/750 Volts - Round

More information

THE UK S BENCHMARK FOR TRI-RATED CABLE

THE UK S BENCHMARK FOR TRI-RATED CABLE THE UK S BENCHMARK FOR TRI-RATED CABLE Welcome to Clynder Cables Clynder Cables has over thirty years of experience in the supply of UK manufactured industrial electrical cables to the UK, European and

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

Go to Contents Page BICC. Previous Page Next Page

Go to Contents Page BICC. Previous Page Next Page 1 CONTENTS Page Introduction... 1 Customer Service... Product Range... Specification and Construction... 5 Salient Features of Ducab s Design... 6 Installation and Electrical Data... 617 XLPE Insulated

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH Welcome to the Prysmian Group, the world s leading cable solutions provider. Over 130 years of aggregated history, 22,000 people in 50 countries and almost

More information

PVC INSULATED HEAVY DUTY CABLES

PVC INSULATED HEAVY DUTY CABLES PVC INSULATED HEAVY DUTY CABLES 1100 V. 9001:2008 14001:2004 OHSAS 18001:2007 Details make the Difference IS 1554 (Part I) Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range A NEW BEGINNING IN OIL & GAS Offshore Cable Range 2 TABLE OF CONTENTS TELE-FONIKA Kable S.A. 2 PRODUCTION POTENTIAL 3 CABLE CODE DESIGNATION 6 BS6883/BS7917 (UKOOA) 6571 SW4 0.6/1kV Single Earthing TCu/EPR/ZH

More information

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information