LOCATION MAP JACKSONVILLE, FLORIDA Deerwood Park Blvd. South Jacksonville, Florida Certificate of Authorization No.

Size: px
Start display at page:

Download "LOCATION MAP JACKSONVILLE, FLORIDA Deerwood Park Blvd. South Jacksonville, Florida Certificate of Authorization No."

Transcription

1 St. Johns Rd. Kernan Blvd. JCKSONVILLE PORT UTHORITY DMES POINT MRINE TERMINL CRUISE Eastport Rd. CSX Broward River S 05 Reddie Point CP Chaseville Johns River TRNSPORTTION 09 Eastport Rd. Quinlan JCKSONVILLE UNIVERSITY Floral Bluff Eggleston Heights rlington rlington Rd. EXCHNGE IS. 0 University Blvd. Dunn Cr. Eastport Heckscher Dr. Drummond Point VICKS ISLND New Berlin Dames Point CP 9 Jct. Cedar Swamp LITTLE MRSH ISLND Dames Point St. Johns Bluff 3 Beacon NEW Hills 7 CSTLE REED 9 ISLND ISLND 50 FORT CROLINE Ft. Caroline Rd. NTIONL PULINE 8 MEMORIL ISLND 5 33 Newcastle 3 Mitchel Bluff 0 Buckhorn Bluff 7 North Shore Jct. PELOTES 3 ISLND BROWNS North IS. Shore Ft. Caroline Rd. Mill Cove Cosmo CP CP Red Bay Br. lta Dr. QURNTINE IS. 5 Terrap Gilmore 6 Merrill Rd. S 3 Strawberry Cr. New Berlin Rd. LLIGTOR ISLND St. Johns River BLOUNT ISLND 9 30 LE BRON ISLND Back R. Dames Point Cut Off nes Cr. Browns Cr. Monument Rd. Holly 7 8 Oaks Clapboard Cr. 39 tlantic Blvd. Estates CRIG 8 MUN 95 IRPORT 7 Cathy Rd 5 Fitzpatrick Cr. Cedar 6 S0 S03 Wonderwood Dr. JP CONTRCT NO. C-6 PROJECT LOCTION 9 INDEX OF PLNS SHEET NO. S00 SD0 S0 S03 S0 S0 S0 S03 S0 S0 S0 S50 N SHEET DESCRIPTION KEY SHEET RMP DEMOLITION PLN STRUCTURL GENERL NOTES STRUCTURL ISOMETRIC - STRUCTURL ISOMETRIC - FOUNDTION PLN RMP FRMING PLN - LOWER RMP FRMING PLN - INTERMEDITE RMP FRMING PLN - UPPER FRMING ELEVTIONS - FRMING ELEVTIONS - FRMING ELEVTIONS - 3 FRMING ELEVTIONS - STRUCTURL SECTIONS FOUNDTION SECTIONS & DETILS SECTIONS ND DETILS FRMING SECTIONS & DETILS VICINITY MP JCKSONVILLE, FLORID LOCTION MP JCKSONVILLE, FLORID E- - E-6 ELECTRICL PLNS (See Index on Sheet E-) DTE DESCRIPTION BY PVD CHECKED BY: JDC PPROVED BY: REP 078 Deerwood Park Blvd. South Jacksonville, Florida Certificate of uthorization No. 560 Engineer of Record: Richard E. Peters, P.E. No.: JCKSONVILLE PORT UTHORITY DMES POINT MRINE TERMINL CRUISE KEY SHEET SHEET DTE CONTRCT NO. S00 JULY 08 C-6 ColeJ 7/3/08 :3:5 M X:\P\ JXPORT GEC 05\ DPMT Cruise Terminal Gangway Final Design\D. - CDD Files\KEYSRD0.DGN

2 TERMINL BUILDING RMP COLUMNS TO REMIN, TYP REMOVE GURD RIL 6'- GURD RIL INFILL TO MTCH GURD RIL TO REMIN RMP TO REMIN ' - 8" REMOVE FOUNDTIONS, TYP (X) 078 Deerwood Park Blvd. South Fax ' - FV 8' - REMOVE STIR TO GRDE OF UNDERGROUND " RCP (T/PIPE -3.5') RMP TO GNGWY TO REMIN REMOVE ELEVTED RMPS ND STRUCTURE. REMOVE CONCRETE BCKFILL ROUND BSE OF COLUMNS ND CUT COLUMNS MIN " BELOW TOP OF CONCRETE, OR REMOVE COLUMNS TO BOTTOM OF BSE PL. BCKFILL W/ CONCRETE. INLET DRINGE STRUCTURE (INVERT -7.95') OF CONC. CRNE RIL BEM CONCRETE CRNE RIL BEM (-.75') RMP DEMOLITION PLN SD0 SCLE: /" = '- 0 8 SCLE: /" = '- TERMINL BUILDING RMP TO REMIN RMP TO GNGWY TO REMIN REMOVE STIR TO GRDE CONCRETE CRNE RIL BEM (-.75') REMOVE ELEVTED RMPS & STRUCTURE RMP DEMOLITION 3D PERSPECTIVE SD0 SCLE: RMP DEMOLITION PLN SD0 7/0/08 7:09:0 PM

3 SYMBOLS & BBREVITIONS B NCHOR BOLT DJ DJCENT FF BOVE FINISH FLOOR B/ BOTTOM OF BC BOTTOM CHORD BLDG BUILDING BM BEM BOTT BOTTOM BRG BERING BTW BETWEEN CCJ CONTRCTION CONTROL JOINT CFMF COLD FORMED METL FRMING CL CENTER LINE CLR CLER CMU CONCRETE MSONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS D DEEP DET DETIL DI DIMETER E ELECTRICL E ECH EJ EXPNSION JOINT EL ELEVTION EMBED EMBEDMENT EOD EDGE OF DECK EP EMBEDDED PLTE EPS EXPNSIVE POLYSTYRENE GEOFOM UL UIP UIPMENT EXIST EXP EXPNSION EXT EXTERIOR FDN FOUNDTION FTG FOOTING FV FIELD VERIFY GLV GLVNIZED GR GRDE IW IN CCORDNCE WITH IF INSIDE FCE INT INTERIOR JT JOINT KSI KIPS PER SQURE INCH LLH LONG LEG HORIZONTL LLV LONG LEG VERTICL LOC LOCTION LSV LONG SIDE VERTICL M MECHNICL MX MXIMUM MC MOMENT CONNECTION MFR MNUFCTURER MIN MINIMUM MSL MEN SE LEVEL OE OR PPROVED UL OC ON CENTER OF OUTSIDE FCE OH OPPOSITE HND PF POWDER CTUTED FSTENER PL PLTE PSF POUNDS PER SQURE FOOT PSI POUNDS PER SQURE INCH R RDIUS REINF REINFORCEMENT SIM SIMILR SLV SHORT LEG VERTICL STD STNDRD STL STEEL T&B TOP ND BOTTOM T/ TOP OF TH THICK TRNS TRNSVERSE TYP TYPICL UNO UNLESS NOTED OTHERWISE FOUNDTIONS:. FOUNDTIONS SHLL BE IN CCORDNCE WITH GEOTECHNICL RECOMMENDTIONS FROM CSI GEO, INC PROJECT NO , JXPORT 75B-PO399, DTED 5/3/08.. LLOWBLE SOIL BERING PRESSURE = 500 PSF 3. FOUNDTIONS ON THE RELIEVING PLTFORM RE DESIGNED FOR MXIMUM BERING PRESSURE OF 500 PSF. CONCRETE:. LL CONCRETE SHLL BE DESIGNED PER CI LL CONCRETE SHLL BE DESIGNED BY N PPROVED LBORTORY, ND THE DESIGN MIX SHLL SUBMITTED TO THE RCHITECT/ENGINEER FOR REVIEW, ND OBTIN PPROVL PRIOR TO USE. LOCTION NORML WEIGHT CONCRETE FOUNDTIONS SLB ON GRDE ELEVTED COMPOSITE DECK LL OTHER CONCRETE 8 DYS 3000 PSI 3000 PSI 000 PSI 3000 PSI 3. NO PIPES OR DUCTS SHLL BE PLCED IN STRUCTURL CONCRETE UNLESS SPECIFICLLY DETILED. SEE RCHITECTURL ND MECHNICL DRWINGS FOR LOCTION OF SLEEVES. MOULDS, FLOOR HINGES, ETC. TO BE CST INTO THE CONCRETE. REINFORCING STEEL:. REINFORCING STEEL SHLL BE DEFORMED BRS CONFORMING TO STM SPECIFICTION 65 GRDE 60. LL MESH REINFORCING SHLL CONFORM TO.S.T.M. SPECIFICTION 06.. SPLICES IN REINFORCING, WHERE PERMITTED, SHLL BE CLSS B TENSION LP SPLICES, U.N.O. 3. MINIMUM LP OF MESH REINFORCING SHLL BE ONE FULL MESH PLUS " OR 6", WHICHEVER IS GRETER.. UNLESS OTHERWISE SHOWN ON DRWINGS, MINIMUM COVER FOR REINFORCING SHLL BE S FOLLOWS: FOOTINGS 3" SLBS ON GRDE TOP THIRD STRUCTURL NOTES DESIGN CRITERI:. LL WORK TO CONFORM TO THE FOLLOWING: 07 FLORID BUILDING CODE - BUILDING, SIXTH EDITION SCE 7-0. LIVE LODS: WLKWYS ND RMPS 3. WIND DESIGN DT (SCE 7-0): ULTIMTE DESIGN WIND SPEED, Vult (3-SECOND GUST) NOMINL DESIGN WIND SPEED, Vasd (3-SECOND GUST) BUILDING RISK CTEGORY WIND EXPOSURE GENERL: 00 PSF 6 MPH 98 MPH II D. CONTRCTOR SHLL VERIFY LL DIMENSIONS ON JOB SITE WITH COMPLETE SET OF LTEST DRWINGS. NOTES ND DIMENSIONS SHLL BE CHECKED ND VERIFIED WITH RCHITECTURL ND STRUCTURL DRWINGS. NY DISCREPNCIES SHLL BE BROUGHT TO THE TTENTION OF THE RCHITECT/ENGINEER BEFORE COMMENCING WORK SO THT PROPER REMEDIL WORK CN BE EXECUTED.. UNLESS SPECIFICLLY DETILED ON THESE DRWINGS, CONTRCTOR SHLL FURNISH ND INSTLL DUTE SHORING, BRCING, ETC. RUIRED TO SFELY EXECUTE LL WORK ND SHLL BE FULLY RESPONSIBLE FOR THE SME. 3. DETILS ND CONDITIONS NOT SPECIFICLLY SHOWN SHLL BE CONSTRUCTED IN CCORDNCE WITH DETILS SHOWN FOR SIMILR CONDITION ND MTERIL. CONDITIONS:. THE CONSTRUCTION SHOWN ON THE DRWINGS WS OBTINED FROM DRWINGS BY W.. GRISWOLD, JR, PE, DTED 8/9/03. THE CONTRCTOR SHLL VERIFY LL CONDITIONS PRIOR TO PROCEEDING WITH WORK. CONTRCTOR SHLL NOTIFY RCHITECT / ENGINEER OF LL EXCEPTIONS TO SSUMED CONDITIONS.. LL REMOVL, CUTTING, DRILLING, ETC. OF CONSTRUCTION SHLL BE PERFORMED WITH GRET CRE IN ORDER TO NOT DMGE THE ND JEOPRDIZE THE INTEGRITY OF THE BUILDING TO REMIN. 078 Deerwood Park Blvd. South Fax HDG HORIZ HS HSS HT HOT DIPPED GLVNIZED HORIZONTL HEDED STUD NCHOR HOLLOW STEEL SECTION HEIGHT VERT VERTICL W WIDE W/ WITH WF WIDE FLNGE WP WORK POINT 5. LL REINFORCING SHLL BE HELD SECURELY IN POSITION WITH STNDRD CCESSORIES IN CONFORMNCE WITH CRSI MNUL OF STNDRD PRCTICE ND CI 53 DURING THE PLCING OF CONCRETE. 6. PROVIDE CORNER REINFORCING TO MTCH HORIZONTL REINFORCING T LL CORNERS OF CONTINUOUS FOOTINGS ND TIE BEMS. 7. LL HOOKS IN REINFORCING BRS SHLL BE N CI STNDRD HOOK, UNLESS NOTED OTHERWISE. 8. REINFORCING BRS CONFORMING TO STM 706 SHLL BE USED FOR BRS RUIRING WELDING. STRUCTURL STEEL:. STRUCTURL STEEL SHLL BE DESIGNED PER THE ISC , THIRTEENTH EDITION. WIDE FLNGE SHPES.S.T.M. 99, Fy = 50 KSI STEEL TUBES.S.T.M. 500, GRDE "C" Fy = 50 KSI STEEL PIPES.S.T.M. 500, GRDE "C" Fy = 6 KSI LL OTHER STEEL.S.T.M. 36, Fy = 36 KSI. LL BOLTS SHLL BE 3/"Ø (STM 35) UNLESS OTHERWISE NOTED. 3. LL NCHOR RODS SHLL BE STM F55 GRDE 36 UNLESS OTHERWISE NOTED. GNGWY NOTES:. GNGWY SHLL BE DESIGNED IN CCORDNCE WITH THE 07 FLORID BUILDING CODE.. WELDING SHLL CONFORM TO NSI/WS D.. 5. MINIMUM SIZE OF LL FILLET WELDS SHLL CONFORM TO TBLE J. OF ISC SPECIFICTIONS EVEN IF SHOWN OTHERWISE ON RCHITECTURL ND STRUCTURL DRWINGS.. GNGWY SHLL BE DESIGNED FOR UNIFORM LIVE LOD OF 00 PSF. 3. GNGWY SHLL BE FBRICTED FROM 606-T6 LUMINUM MTERIL. 6. FBRICTOR SHLL SUBMIT SHOP DRWINGS TO STRUCTURL ENGINEER FOR REVIEW PRIOR TO STRT OF FBRICTION. FBRICTION SHLL CONFORM TO ISC SPECIFICTIONS.. BREK LL EDGES BOVE DECK LEVEL. 5. HNDRIL, GURDS ND INFILL SHLL COMPLY WITH THE 07 FLORID BUILDING CODE CCESSIBILITY. 7. LL STRUCTURL STEEL ND METL DECK SHLL BE FIELD PINTED PER THE SPECIFICTIONS. 6. PIPE RIL SHLL HVE BRUSH FINISH FTER FBRICTION. 7. SUBMIT SHOP DRWINGS FOR PPROVL PRIOR TO FBRICTION. SHOP DRWINGS SHLL BE SIGNED ND SELED BY PROFESSIONL ENGINEER REGISTERED IN THE STTE OF FLORID. METL FLOOR DECK NOTES:. LL STEEL FLOOR DECK SHLL BE IN CONFORMNCE WITH THE LTEST EDITION OF THE STEEL DECK INSTITUTE (SDI). 8. BSIS OF DESIGN: BELLINGHM MRINE INDUSTRIES, INC. CNOPY NOTES:. CNOPY SHLL BE IN CCORDNCE WITH THE 07 FLORID BUILDING CODE.. LL STEEL FLOOR DECK SHLL BE GLVNIZED G LL FLOOR DECK SHLL BE TYPE.5C, 8 G THICKNESS, WITH MIN YIELD STRENGTH OF 0 KSI.. FLOOR DECK MINIMUM PROPERTIES: Ip = 0.79 in /ft, In = 0.8 in /ft, Sp = 0.30 in 3 /ft, Sn = 0.35 in 3 /ft.. STEEL POSTS, PURLINS ND HOOPS SHLL CONFORM TO STM 53 GRDE ND SHLL BE HOT DIP GLVNIZED. 3. BOLTS SHLL BE STINLESS STEEL ND CONFORM TO STM 307 ND 35.. SHDE FBRIC MTERIL SHLL MTCH ND SHLL HVE 0 YER WRRNTY GINST FDING, ROT, UV DETERIORTION, LOSS OF STRENGTH, COLOR CHNGE OR FULTY WORMNSHIP. 5. BSIS OF DESIGN: SHDE MERIC, ST. UGUSTINE, FLORID.. FLOOR SLB SHLL HVE N OVERLL NOMINL THICKNESS OF 3 /" FROM TOP OF CONCRETE TO BOTTOM OF METL DECK, UNO. REINFORCE W/ 6X6- W. X W.. 5. REINFORCING FOR SLB SHLL BE 3/" FROM TOP OF SLB. 6. LL FLOOR DECK SHLL BE FSTENED TO STEEL SUPPORTS T ENDS OF SHEET ND INTERMEDITE SUPPORTS. MIN BERING LENGTH = /." SUPPORT FSTENERS SHLL BE 5/8" DI PUDDLE WELD, WITH SPCING OF MX " OC. 7. DECKING SHLL HVE NESTED OR INTERLOCKING SIDE LPS. SIDE LPS SHLL BE FSTENED WITH #0 DRILL SCREWS T MX 36" OC. 8. LL DECKS SHLL RE DESIGNED FOR SINGLE SPNS. TWO OR MORE SPNS MY BE USED WHERE GEOMETRY LLOWS. 9. SEE SHEET S-50 FOR METL FLOOR DECK DETILS STRUCTURL GENERL NOTES S0 7/0/08 7:08:50 PM

4 NOTES:. PERSPECTIVE VIEWS RE PROVIDED FOR REFERENCE ONLY. NOT LL FRMING IS NECESSRILY VISIBLE IN VIEW. THESE VIEWS SHOULD NOT BE USED FOR BIDDING, DETILING, FBRICTION, OR ERECTION PURPOSES. PROPOSED RMPS ND PLTFORMS WHRF EDGE 078 Deerwood Park Blvd. South Fax UNDERGROUND CONCRETE PIPE RMP TO GNGWY CONC. CRNE RIL BEM NEW RMP TO LOWER PROPOSED PLTFORM PLTFORM RMPS TO BE DEMOLISHED 3D PERSPECTIVE - BUILDING SIDE S03 SCLE: STRUCTURL ISOMETRIC - S03 7/0/08 7:09:0 PM

5 NOTES:. PERSPECTIVE VIEWS RE PROVIDED FOR REFERENCE ONLY. NOT LL FRMING IS NECESSRILY VISIBLE IN VIEW. THESE VIEWS SHOULD NOT BE USED FOR BIDDING, DETILING, FBRICTION, OR ERECTION PURPOSES. 078 Deerwood Park Blvd. South Fax D STRUCTURL_VIEW S0 SCLE: STRUCTURL ISOMETRIC - 3D STRUCTURL_VIEW S0 SCLE: S0 7/0/08 7:09:03 PM

6 ' - " 3' - 7 /8" 3' - 7 /8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - 7' - 3" 5' - /" " 8' - " 35' - 7" F E 9' - 3' - F5S EL.-8" HSS6X6X/ CL GNGWY HSS6X6X/ F EL.-8" HSS6X6X/ HSS6X6X/ F5 EL.-8" EXIST UG ELECTRICL, PROVIDE NOTCH IN B/FTG (" CLR OF CONDUIT) HSS6X6X/ HSS6X6X/ F5 EL.-8" HSS6X6X/ HSS6X6X/ F5 EL.-8" HSS6X6X/ HSS6X6X/ F5 EL.-8" HSS6X6X/ HSS6X6X/ ' - 7" (VIF) 3 F EL.-8" HSS6X6X/ HSS6X6X/ F EL.-8" TO EXIST WTER LINE 3' - TO EXIST COL HSS6X6X/ HSS6X6X/ '- (FV) ' - FV 3' - FV 6' - FV EXIST COL TO REMIN, TYP HSS6X6X/ HSS6X6X/ TERMINL BUILDING EXIST FTG TO REMIN TYP. CIP CONCRETE RMP 078 Deerwood Park Blvd. South Fax D 8' - ' - HSS6X6X/ HSS6X6X/ HSS6X6X/ HSS6X6X/ HSS6X6X/ HSS6X6X/ HSS6X6X/ HSS6X6X/ F0 EL.-8" HSS6X6X/ F0 EL.-8" HSS6X6X/ UP 3 INLET DRINGE STRUCTURE (INVERT -7.95') OF UNDERGROUND " RCP (T/PIPE -3.5') 6' - 0 /" EXIST INLET W TYP T D-E-F COMBINED FOOTINGS EXIST UG WTERLINE 0'- OF CONC. CRNE RIL BEM B F5 EL. HSS8X8X/ HSS8X8X/ EXIST CNOPY OVER WLKWY TO REMIN CONCRETE CRNE RIL BEM (-.75') 6' - 0 /" 6" OR 8" PIPE IN SPCE BETWEEN RELIEVING WHRF ND DECK (FV) F5 EL. HSS8X8X/ HSS8X8X/ 0'- WHRF 5' - 0 /" EDGE OF WHRF ST. JOHN'S RIVER FOUNDTION PLN S0 SCLE: /8" = ' SCLE: /8" = '- FOUNDTION PLN NOTES:. DRWING ELEVTION 0'- = 9'- MSL (NOMINL T/WHRF EL).. F INDICTES SPRED FOOTING TYPE. SEE PLN & SCHEDULE, THIS SHEET. FLG NOTES: CST TO EDGE OF STORM DRIN W/ /" EXP JOINT PROVIDE PVC PIPE SLEEVE WITH MINIMUM OF " GP LL ROUND 3 EXIST LIGHT POLE FOUNDTION SCHEDULE TYPE LENGTH WIDTH THICKNESS REINFORCEMENT " Foundation 5' - " 8' - 9/" " Slab 6 X 6 ' - " ' - " ' - PILSTER F ' - ' - " / 8", SEE SECTION 5-#5 LONG, 3-#5 SHORT T & B F5 ' - 5' - " / 8", SEE SECTION 8-#5 LONG, 3-#5 SHORT T & B F5S ' - 5' - 3 / 8", SEE SECTION 8-#5 LONG, -#5 SHORT T&B F0 3' - 0' - ' - - #5 LONG, # SHORT, CENTERED F5 5' - 5' - 3' - 6-#5 LONG, 7-#5 SHORT T & B FOUNDTION PLN S0 7/0/08 7:09:0 PM

7 ' - " 3' - 7 /8" 3' - 7 /8" 8' - /" 36' - /" 8' - /" 8' - 7' - 3" 5' - /" 5' - /" F E D 9' - 8' - " 8' - " S0 HSS0X6X5/6 HSS6XX5/6 HSS0X6X5/6 9' - 8" HSS0X6X5/6 T/STL EL 9'- /" S03 HSS6XX5/6 HSS6XX5/6 S0 HSS0X6X5/6 HSS0X6X5/6 ' - " HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 7' - " HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 ' - 7" HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 35' - 7" TO EXIST WTER LINE S0 HSS0X6X/ HSS0X6X5/6 ' - 8" ' - " HSS6XX5/6 (SLV) 0'- TERMINL BUILDING UP 3 INLET DRINGE STRUCTURE (INVERT -7.95') OF UNDERGROUND " RCP (T/PIPE -3.5') 078 Deerwood Park Blvd. South Fax ' - 9" ' - /" 5' - 5' - 5' - 6' - 0 /" S03 OF CONC. CRNE RIL BEM S0 CONCRETE CRNE RIL BEM (-.75') B 6' - 0 /" 3 S0 S0 0'- WHRF EDGE OF WHRF ST. JOHN'S RIVER RMP FRMING PLN - LOWER S0 SCLE: /8" = ' NOTES:. T/STL STRINGER IS +" FROM T/DECK. T/STL HSS 6X BEM IS (-) 7" FROM T/DECK, LNDINGS WHERE IT IS (-) 3/". 3. SEE SHEET FOR TYPICL CONNECTIONS.. PROVIDE CONTRCTION CONTROL JT'S T MX 5'- OC T RMPS, TYP. SEE FOR DETIL. SCLE: /8" = '- RMP FRMING PLN - LOWER S0 7/0/08 7:09:0 PM

8 ' - " 3' - 7 /8" 3' - 7 /8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - " 8' - " F E D 9' - 8' - HSS0X6X5/6 ' - 9" 5' - ' - /" 5' - ' - 8" 7' - " HSS0X6X5/6 HSSX6X3/8 HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 ' - " S0 HSSX6X3/8 HSSX6X3/8 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 HSS0X6X5/6 S03 HSS6XX5/6 HSS6XX5/6 S0 HSS0X6X5/6 HSS0X6X5/6 9' - 8" 7' - " HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSSX6X3/8 HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 DN UP HSS0X6X5/6 HSS0X6X5/6 NEW PLTFORM ' - 8" HSS0XX5/6 S0 HSS0X6X5/6 ' - 8" S03 PLTFORM TERMINL BUILDING 078 Deerwood Park Blvd. South Fax RMP FRMING PLN - INTERMEDITE S03 SCLE: /8" = ' NOTES: SCLE: /8" = '-. T/STL STRINGER IS +" FROM T/DECK. T/STL HSS 6X BEM IS (-) 7" FROM T/DECK, LNDINGS WHERE IT IS (-) 3/". 3. SEE SHEET FOR TYPICL CONNECTIONS.. PROVIDE CONTRCTION CONTROL JT'S T MX 5'- OC T RMPS, TYP. SEE FOR DETIL. FLG NOTES: CONTRCTOR SHLL DESIGN ND CONSTRUCT TEMPORRY CCESS STIR FROM LEVEL '-8". MODIFY HNDRIL TO MEET FBC ND OSH RUIREMENTS. STIRS SHLL BE REMOVED ND HNDRIL RESTORED FTER CONSTRUCTION. HSS 0X6X5/6 6' - ' - (VIF) HSS 6X6X5/6 HSS 0XX5/6 T/STL EL '-8" '-8" TSXX/ COLUMNS HSS 0XX5/6 HSS 0X6X5/6 ENLRGED CROSSOVER PLN S03 SCLE: /" = '- RMP FRMING PLN - INTERMEDITE S03 7/0/08 7:09:0 PM

9 ' - " 3' - 7 /8" 3' - 7 /8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - " 8' - " F E D 9' - 8' - ' - 9" 5' - ' - /" 5' - ' - " CNOPY EXTENTS, TYP ' - 8" 7' - " 37' - " HSS0X6X5/6 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS6XX5/6 ' - TYP ' - TYP HSSX6X3/8 S0 HSSX6X3/8 HSSX6X3/8 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 3' - 8" S03 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 S0 HSS0X6X5/6 HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 3' - " HSS0X6X5/6 HSS6XX5/6 HSS6XX5/6 HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 9' - 8" HSS6XX5/6 HSS6XX5/6 DN HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 S0 F E D TERMINL BUILDING 078 Deerwood Park Blvd. South Fax CNOPY EXTENTS, TYP 6' - 0 /" HSSX6X3/8 HSSX6X3/8 S03 8' - " S0 DN B W0X39 ' - TYP B HSS6XX5/6 L6X6X5/6 L6X6X5/6 3/8" GUSSET () BOLTS PER NGLE 6' - 0 /" HSSX6X3/8 HSS0X6X5/6 HSSX6X3/8 39' - 3 S0 6' - 0 /" HSS6XX5/6 L6X6X5/6 L6X6X5/6 HSS6XX5/6 ' - TYP 3 S0 S0 W0X39 8' - " 8' - 6" L6X6X5/6 (TYP) L6X6X5/6 8' - " 8' - 6" 5 SX3.8 W/ C0X5.3 3/8" GUSSET 3 RMP FRMING PLN - UPPER MONORIL SUPPORT FRMING PLN RMP FRMING PLN - UPPER S0 SCLE: /8" = ' S0 SCLE: 3/6" = '- 0 8 NOTES:. T/STL STRINGER IS +" FROM T/DECK. T/STL HSS 6X BEM IS (-) 7" FROM T/DECK, LNDINGS WHERE IT IS (-) 3/". 3. SEE SHEET FOR TYPICL CONNECTIONS.. PROVIDE CONTRCTION CONTROL JT'S T MX 5'- OC T RMPS, TYP. SEE FOR DETIL. SCLE: /8" = '- SCLE: 3/6" = '- S0 7/0/08 7:09:05 PM

10 F E D B 9' - 8' - 6' - 0 /" 6' - 0 /" L0X0X3/ 9 SIM L6X6X5/6 MONORIL SUPPORT 53' - 8" 5' - " 6' - 0 /" L0X0X3/ B D E 8' - 9' - F MONORIL SUPPORT 53' - 8" 078 Deerwood Park Blvd. South Fax Level 5 37' - " SIM HSS0X6X5/6 LXX5/6 HSSX6X3/8 HSSX6X3/8 () L6X6X5/6 L8X8X/ MX. HT 39' - WP EL. 38' - 6/" MX. HT 39' - ' - 3" L8X8X/ HSSX6X3/8 L6X6X5/6 HSS6X6X/ HSS0X6X5/6 0 L6X6X5/6 HSS6X6X/ L6X6X5/6 5 HSS6X6X/ HSS8X8X/ () () L6X6X5/6 L6X6X5/6 HSS8X8X/ HSS8X8X/ L6X6X5/6 L6X6X5/6 7 HSS8X8X/ HSS6X6X/ HSS6XX5/6 HSS6X6X5/6 HSS6X6X/ HSS6XX5/6 HSS6X6X5/6 5 HSS6X6X/ L6X6X5/6 L6X6X5/6 () L6X6X5/6 L6X6X5/6 HSS6X6X5/6 HSS6X6X5/6 8 GRDE ' - 6" GRDE WP EL. ' - 6" GRDE ' - 6" 8" GRID FRMING ELEVTION S0 SCLE: 3/6" = '- 3 GRID FRMING ELEVTION S0 SCLE: 3/6" = '- FRMING ELEVTIONS SCLE: 3/6" = '- S0 7/0/08 7:09:05 PM

11 F E D D E F 8' - 9' - 9' - 8' - T/DECK HSS0X6X5/6 HSS0X6X5/6 LNDING 9' - 8" 078 Deerwood Park Blvd. South Fax HSS6X6X/ HSS6XX5/6 SLV HSS6X6X/ HSS6XX5/6 L6X6X5/6 HSS6X6X/ 7' - 6" 7' - 6" " HSS6X6X/ L6X6X5/6 L6X6X5/6 HSS0X6X5/6 HSS6X6X/ HSS0X6X5/6 HSS6X6X/ 3 5/6" ' - 8" HSS6XX5/6 L6X6X5/6 HSS0X6X5/6 L6X6X5/6 L6X6X5/6 7' - 0 9/6" L6X6X5/6 L6X6X5/6 L6X6X5/6 WP EL. 8" 6' - 0 /" GRDE GRDE GRID FRMING ELEVTION S0 SCLE: 3/6" = '- GRID 9 FRMING ELEVTION S0 SCLE: 3/6" = ' ' - " 3' - 7/8" 3' - 7/8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - 8' - 7/8" 7' - 0 5/8" HSS6X6X/ HSS0X6X5/6 L6X6X5/6 7 L6X6X5/6 HSS6X6X/ HSSX6X3/8HSS0X6X5/6 HSS6X6X/ ' - 5 /" 5' - 6 3/8" HSS0X6X5/6 L8X8X/ L8X8X/ HSS6X6X/ HSS0X6X5/6 0' - 6 3/8" L8X8X/ HSS0X6X5/6 L8X8X/ HSS6X6X/ HSS0X6X5/6 ' - 05/8" HSS0X6X5/6 HSS6X6X/ HSS0X6X5/6 3' - 7/8" HSS0X6X5/6 WP ' - 7" 7 HSS6X6X/ HSS0X6X5/6 L6X6X5/6 HSS0X6X/ L6X6X5/6 HSS6X6X/ 8 LNDING 9' - 8" ' - 8" FRMING ELEVTIONS - WP EL. 8" WP EL. 8" 8 8 GRDE S0 GRID F FRMING ELEVTION S0 SCLE: 3/6" = '- 0 8 SCLE: 3/6" = '- 7/0/08 7:09:05 PM

12 ' - 3' - 8 /8" 3' - 7 /8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - 7' - 3" 5' - /" 37' - " ' - " HSS6X6X/ " " HSS0X6X5/6 HSSXX/ HSSXX/ HSSXX/ HSS6X6X/ HSSX6X3/8 HSSX6X3/8 3' - 0 3/" 9' - 0 3/" 9' - 8" HSS6X6X/ 33' - 95/8" HSS0X6X5/6 HSS0X6X/ HSS0X6X5/6 L8X8X/ L8X8X/ 3' - 33/8" HSS6X6X/ HSS0X6X5/6 HSS0X6X5/6 L8X8X/ L8X8X/ HSS6X6X/ HSS0X6X5/6 7' - 33/8" HSS0X6X5/6 7' - 33/8" HSS6X6X/ 3' - /8" HSS0X6X5/6 HSS0X6X5/6 HSS6X6X/ HSS0X6X5/6 HSS6X6X5/6 HSS6X6X5/6 HSS0X6X5/6 HSS6X6X5/6 HSS6X6X/ 7 Level 5 37' - " LNDING 9' - 8" ' - 8" 078 Deerwood Park Blvd. South Fax HSSXX/ WP 8" L8X8X/ HSS0X6X5/6 L8X8X/ HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSS0X6X5/6 HSS6X6X/ GRDE GRID D FRMING ELEVTION S03 SCLE: /8" = ' ' - " 3' - 7 /8" 3' - 7 /8" 8' - /" 8' - /" 8' - /" 8' - /" 8' - 7' - 3" 5' - /" T/RMP 3' - 0 3/" 33' - 9 /" HSS6XX5/6 HSSX6X3/8 HSS0X6X5/6 3' - 3 3/8" 3' - /8" Level 5 37' - " HSS0X6X5/6 HSS6X6X/ HSS6X6X/ HSSX6X3/8 9' - 0 3/" 3 HSS6X6X/ L8X8X/ 8' - 9/" 8' - 9/" L8X8X/ HSS6X6X/ L8X8X/ HSS0X6X5/6 L8X8X/ HSS6X6X/ 7' - 3 3/8" 7' - 3 3/8" HSS6X6X/ 6' - /8" HSS0X6X5/6 6' - /8" HSS6X6X/ HSS6X6X/ ' - 5" 6" LNDING 9' - 8" ' - 8" WP 8" HSS0X6X5/6 HSS0X6X5/6 HSS0X6X/ 8 (OPP HND) GRDE FRMING ELEVTIONS - 3 GRID E FRMING ELEVTION S03 SCLE: /8" = ' SCLE: /8" = '- S03 7/0/08 7:09:06 PM

13 3 8' - " T/STL 39' Deerwood Park Blvd. South Fax MX. HT 39' - HSS0X6X5/6 38' - " WP EL. L6X6X5/6 HSS8X8X/ L6X6X5/6 HSS8X8X/ L6X6X5/6 L6X6X5/6 GRDE WP EL. ' - 6" GRID FRMING ELEVTION S0 SCLE: 3/6" = '- 07/9/8 Checker uthor Designer FRMING ELEVTIONS - S0 C:\_ctive Revit Projects\ _JXPORT Cruise Gangway_S_R7_dstaples.rvt 7/0/08 5:07: PM

14 F E D SEE PLN 9' - 8' - SEE PLN CNOPY STRUCTURE BY CNOPY MFR. 078 Deerwood Park Blvd. South Fax ' - CLR 3' - T/COL TYP LNDING HSS6X6X/ HSS6X6X/ S50 TYP HSS6X6X/ 7" EXCEPT T LNDING T/ LNDING T/ STEEL HSS6XX5/6 8' - ' - TYPICL RMP SECTION SCLE: /" = '- GNGWY COUNTER-SINK MRINE GRDE SCREWS BY GNGWY MFR. COORDINTE TP SIZE & LOCN W/ MFR. 0X6X3/8 HINGE NGLE W/ NON-SKID RIBS, BY GNGWY MFR. B MX. HT 39' - 5' - " /" CP PL 6' - 0 /" 3 3/" T/COL EL 5'-7" MONORIL SUPPORT 53' - 8" LXX/ 5 GNGWY (BY GNGWY MFR) () BOLTS PER NGLE TYP () 3/" BOLTS, TYP GNGWY CONN DETIL SCLE: /" = '- SCLE: /" = '- SHIP 3 MONORIL SUPPORT SECTION MX. HT 39' - / 5 SECTION SCLE: 3/" = '- S PL 3/8" C0 0 8 SCLE: /" = '- 0 SCLE: /" 0 = '- 3 SCLE: 3/" = '- STRUCTURL SECTIONS 7/0/08 7:09:06 PM

15 F E D 3' - 0 /6" 9' - 8' - ' - ' - GRDE EXIST SPHLT OVER GRVEL, FV SLB ON GRDE W/ 6X6-W.XW. WWR. MEET & MTCH EXIST PVEMENT HSS COL, SEE PLN, TYP BSE PL. & NCHOR RODS, SEE S-50 /" EXP JT, TYP ' - 6" 3' - 6" FV 3/" CHMFER, TYP CUT & CONTIN EXIST GRVEL. REUSE S FILL ROUND NEW FDN EXIST SPHLT OVER GRVEL, FV GRDE 3' - 5" 8' - " 3' - 5" *NOTE: BRCING NOT SHOWN FOR CLRITY. SEE ELEVTIONS 6-# -#6 TOP HSS COL, SEE PLN, TYP BSE PL. & NCHOR RODS, SEE S-50 '- SQ X DEEP POCKET. FILL W/ CONC FTER STEEL INSTLLTION 3-# SIDES EXP JT, TYP +/- FV 078 Deerwood Park Blvd. South Fax CUT & CONTIN EXIST GRVEL. REUSE S FILL ROUND NEW FDN FDN REINF, SEE SCHEDULE ON SHEET S0 RCP ' - EXIST RELIEVING PLTFORM 3' - 6-#6 TOP & BOTT 7-#6 TOP & BOTT FDN REINF, SEE SCHEDULE ON SHEET S0 FOUNDTION F5 SECTION SCLE: /" = '- FOUNDTION F5 SECTION SCLE: /" = '- COLUMN SLOPE TOP OF PEDESTL W/ RMP 3/" CHMFER, TYP 0 30' - 9" CURB 6X6 PEDESTL W/()# DOWELS & #3 " CONC SLB REINF W/ " TRNS & 6-# LONGITUDINL. PROVIDE CRCK CONTROL JT'S IN SLB T MX 5'- OC. ' - ' - /" GURD RIL W/ LEXN INFILL 6" CURB, ECH SIDE OF RMP PEDESTL DETIL SCLE: 3/" = '- 6" 7' - 6" 6" PL WSHER. W/ STD. HOLE TYP /" NON-SHRINK GROUT ' - EMBED. EPS FILL REINF NOT SHOWN FOR CLRITY 3 BOTTOM OF RMP SECTION SCLE: /" = '- BSE PLTE T/PIER OR PIER CP OVERSIZED HOLE IN BSE PL TYP. NCHOR ROD TCK WELD NUT TO SHFT PEDESTL, BEYOND 5 ' - " 8" " ' - " 8" " HSS6x6 3/" DI NCHOR ROD, SEE DET 6/ / " CONC SLB ON GRDE SPRED FOOTING, SEE PLN BSE PL 3/" ' - " " " ' - " " " HSS8x8 ' - 3/" DI NCHOR ROD, SEE DET 6/ / BSE PL 3/" ' - GRDE T/ /8 T/RMP GRDE T VRIES 6" ' - CRCK CONTROL JOINT (C.C.J.) SEE PLN MIN ' - MIN 6" 6" CIP WLL* T *CONSTRUCTION JOINT (C.J.) SWCUT JOINT #@" (6) # CONT EPS FILL *PROVIDE CST-IN V-GROOVE VERT. JT'S T OUTSIDE FCE OF WLLS T MX 5'- OC 5 TYPICL RMP SECTION SCLE: 3/" = '- # SMOOTH DOWEL BR T '- O.C. COT ONE END TO PREVENT BOND. T /" PREMOLDED EXPNSION JOINT MTERIL EXPNSION JOINT (E.J.) NOTES:. C.C.J. SHLL BE PREFORMED OR SWED. IF SWED, SWING MUST TKE PLCE WITHIN HRS. OF SLB PLCEMENT. MTCH LOCTIONS OF CCJ'S.. * USE INSTED OF CRCK CONTROL JOINT WHEREVER CONSTRUCTION IS STOPPED OR WHERE CLLED FOR ON PLN. " " #3 CONT CIP WLL* #@6" #@" 0 SCLE: /" = '- 0 3 FOUNDTION SECTIONS & DETILS 6 TYPICL NCHOR ROD DETIL SCLE: /" = '- 7 TYPICL BSE PLTE DETILS SCLE: /" = '- 8 SLB ON GRDE JOINT DETILS SCLE: 3/" = '- SCLE: 3/" = '- 7/0/08 7:09:08 PM

16 HSS XX/ TOP RIL RILS LIGN INSIDE FCES OF POSTS & RILS HSS XX/ TOP RIL ' - LONG PLN NORTH SIDE OF RMPS, TYP 078 Deerwood Park Blvd. South Fax HNDRIL 3 /" 8" 3' - 3' - POST BEYOND HSS /X / X/ T MX '- OC (TYP POST) HSS XX/ BOTT RIL NOTE 3' - 8" 6" " LXX/ CONT " HSS STRINGER, SEE PLN ND ELEVTION TYP NOTE: /" METL DECK FILLED W/CONCRETE (3 /" TOTL THICKNESS) SEE S0 FOR DETILS GURDRIL DETIL S50 SCLE: " = '- 07/0/8 Checker uthor Designer SECTIONS ND DETILS 0 S50 SCLE: " = '- 7/0/08 7:09:08 PM

17 3/6 CLR CP PL /" (+/" LL ROUND) / 3/6 CLR CP PL /" (+/" LL ROUND) / T/DECK 7" ' - 3/6 NOTES:. TOP LEG OF NGLES SHLL BE HORIZONTL.. WELD NGLE BRCES LL ROUND MINIMUM DIMENSIONS SHOWN RE FOR GUSSET SIZE DETERMINTION. 3. SEL LL GPS WITH SILICONE SELNT PRIOR TOUCH-UP PINTING. 3 /" HSS COLUMN, SEE PLN & ELEV / / HSS STRINGER, SEE PLN & ELEV TOP OF RMP (BEYOND) " HSS COLUMN, SEE PLN & ELEV 7" / / HSS STRINGER, SEE PLN & ELEV TOP OF RMP (BEYOND) 3/6 HSS COLUMN BEYOND, SEE PLN & ELEV - L7XX3/8X0'-6" LG HSS STRINGER, SEE PLN & ELEV HSS STRINGER, SEE PLN & ELEV 078 Deerwood Park Blvd. South Fax /6 / 5/6" END PL, TYP / / / / LXX/ X COL WIDTH BERING NGLE / 5/6" END PL / / BENT PL / X X X COL WIDTH / / HSS GIRDER, SEE PLN & ELEV 7" / TOP OF RMP (NOT SHOWN FOR CLRITY) 3 SIDES USE SELNT ON BCK SIDE 3/6 3 BEM CONN DETIL 3 SCLE: 3/" = '- BEM CONN DETIL SCLE: 3/" = '- BEM CONN DETIL SCLE: 3/" = '- / BEM CONN DETIL SCLE: 3/" = '- / / HSS COLUMN, SEE PLN & ELEV BRCE, SEE ELEV ()-3/" DI 35 BOLTS TYP - 3/8" GUSSET PLTE HSS COLUMN, SEE PLN & ELEV BRCE, SEE ELEV WP GUSSET PL 3/8 T CENTER OF COL BRCE, SEE ELEV HSS COLUMN, SEE PLN & ELEV WP BRCE, SEE ELEV ()-3/" DI 35 BOLTS TYP HSS COLUMN, SEE PLN & ELEV BRCE, SEE ELEV GUSSET PL 5/6 3/6 WP 3/6 3/6 3/6 GUSSET PL 3/8" T CENTER OF COL 3/6 WP 3/6 " MIN * BOLTED OPTION PER BRCE DETIL 3 8 BRCE DETIL 3/6 3/6 ()-3/" DI 35 BOLTS TYP SCLE: 3/" = '- 5 BRCE DETIL SCLE: 3/" = '- 6 BRCE DETIL SCLE: 3/" = '- BRCE, SEE ELEV CONTRCTOR HS THE OPTION TO USE BOLTED OR WELDED CONNECTION (BOTH RE SHOWN) 7 BRCE DETIL 3 HSS 6XX/ CURB W/END CPS 3/6 B 3/8" CONNECTION PL CUT FROM PIECE SEE B-B SCLE: 3/" = '- 3 /" PL 3/8" () 3/"DI 35 E SIDE & CENTER 9 BRCE DETIL 5 SCLE: /" = '- 3 /" /" MIN WP HSS 3/8" END & GUSSET PL 0 BRCE DETIL 6 SCLE: 3/" = '- SEE BRCE CONN DETIL WHEN PPLICBLE SEE BEM CONN DETIL FOR DD'L INFO 3/6 () 3/" DI 35 BOLTS T/DECK EL 39'- WP EL 37'-9" UPPER BRCE WP HSS X6 SEE BEM CONN DETIL FOR DD'L INFORMTION BRCE DETIL 7 SCLE: 3/" = '- SEE BRCE CONN DETIL WHEN PPLICBLE SEE BEM CONN DETIL FOR DD'L INFO PL 3/8" - / 3/8" PLTE B - " " " B-B " " 5" BRCE DETIL 8 SCLE: /" = '- /" FILLET WELD OF CONNECTION PLTE TO LL FLTS OF HSS SEL LL ROUND 0 3 SCLE: 3/" = '- 0 SCLE: /" = '- FRMING SECTIONS & DETILS 7/0/08 7:09:09 PM

18 PNEL N PROJECT NOTES. WHERE FOOTERS OR FOUNDTIONS RE INSTLLED BYUGERINGOR DRILLING, SURVEYND STKE OR PINT TON CCURCYOF 0.' PRIOR TORUESTINGUTILITYLOCTES. STKE OR PINT THE CENTER OF ECH LOCTION ND CLERLY LBELWITH STTION, OFFEST, IDENTIFYINGSTRUCTURE NUMBER, ND DIMETER OF EXCVTION IN INCHES.. WHERE UGERINGOR DRILLING, EXCVTE THE FIRST FEET BYNON MECHNICLND NON DESTRUCTIVE MENS. INDEX OF ELECTRICL PLNS SHEET NO. SHEET DESCRIPTION E- KEY SHEET, PROJECT NOTES, ND LEGEND DESCRIPTION E- ELECTRICL SITE PLN E-3 ONE-LINE DIGRM, ELEC. ROOM LYOUTS, ND PNEL SCHEDULE E- GNGWY CONDUIT ROUTING ELEVTION DETILS E-5 ELECTRICL SPECIFICTIONS E-6 ELECTRICL SPECIFICTIONS RE OF WORK LEGEND DESCRIPTION PLN SYMBOLS SURFCE MOUNTED CONDUIT WITHIN OPEN CEILING, S INDICTED ON DRWINGS. ()-" RIGID GLVNIZED METL CONDUIT WITH TYPE THWN- CONDUCTORS INSIDE (CONDUIT ND CONDUCTOR SIZE S SHOWN ON PLN SHEETS) FOR ELECTRICL FEEDER. ()-" RIGID GLVNIZED METL CONDUIT WITH PULL CORD FOR PROPOSED CMERS. CONDUIT ROUTING INDICTED ON PLNS. C RECESSED IN-GRDE PRECST PULL BOX (HNDHOLE) FOR FUTURE UNDERGROUND TELECOMMUNICTIONS ND WITH THE FOLLOWING NOMINL INSIDE DIMENSIONS: 3" Wx" Lx" D. PULLBOX SHLL BE PROVIDED WITH BOLT DOWN CHECKERED STINLESS STEEL LID IDENTIFIED S "COMMUNICTIONS". E RECESSED IN-GRDE PRECST PULL BOX FOR UNDERGROUND ELECTRIC ND WITH THE FOLLOWING NOMINL INSIDE DIMENSIONS: " Wx36" Lx" D. PULLBOX SHLL BE PROVIDED WITH BOLT DOWN CHECKERED STINLESS STEEL LID IDENTIFIED S "ELECTRICL". J CCESSIBLE JUNCTION BOX CONDUIT RISER (STUB-UP) ND UNDERGROUND TRNSITION. PROJECT SITE NOT TO SCLE ELECTRIC MOTOR (FURNISHED BY OTHERS) MP HOMERUN CIRCUIT. NUMBER REPRESENTS CIRCUIT DESIGNTION. LETTERS REPRESENT PNEL SOURCE. SINGLE-POINT TERMINTION TO FURNISHED UIPMENT. SURFCE MOUNTED FUSED DISCONNECT X X-X DETIL CLLOUT ONE-LINE SYMBOLS TRNSFORMER PNELBORD / LOD CENTER CIRCUIT BREKER FUSED DISCONNET, SIZES S INDICTED ON DRWINGS M KILOWTT DEMND METER ELECTRIC MOTOR G GENERTOR No Nc UTOMTIC TRNSFER SWITCH (TS) DESCRIPTION BY PVD DO DO CHECKED BY: SJC PPROVED BY: JDC 078 Deerwood Park Blvd. South Jacksonville, Florida Certificate of uthorization No. 560 Engineer of Record: Stephen Conway, P.E. No.: 5353 JCKSONVILLE PORT UTHORITY DMES POINT MRINE TERMINL CRUISE KEY SHEET, PROJECT NOTES, ND LEGEND DESCRIPTION SHEET DTE CONTRCT NO. E- JULY 08 C-575 $USER$ $FILE$ $DTE$ $TIME$

19 GBGV GBGV GBGV GBGV GBGV GBGV GBGV GBGV N Feet HSSS GMHD SD 36" STORM MH. HSSS HPST5.3 HPST HPST HPST8. HPST.60 HPST.66 HPST0.53 HPST9.35 HPST8. HPST7. HPST6. HPST5.35 HPST. HPST3.7 HSSS 8. HSSS3 8.5 HPST HPST HPST HPST7 7.6 HSSS HPST6 8.8 HPST6 7.9 HPST HPST HPST DROP OFF HFH HVLV WTER HPST HPST3 5.6 GMHD3 SD 36" STORM MH. 7.8 SD GMHD " STORM MH. HPST HPST HPST HPST HVLV SPRINKLER CONTROL VLVE WTER GW V WTER KLP GFU CONC. POLE W/ CMER 7.7 HPST HPST7 8.9 H WPB JE GPST GSRVC GFU 8.06 GPST GW V WTER GWPB GCLNO " PVC GMH BUILDING FOOTPRINT ELEC. ROOM CUSTOMS/INS E-3 GH ML GPST GSRVC GPST.7' X.7' GWPB GW V WTER 8.56 GSRVC GW M WTER ' X.5' GMH MDF ROOM SD GMHD TYPICL GMH KLP KWPB CONC. LP GROUND WIRE KWPB ELECTRIC KLP CONC. LP 6.8 KLP 6.80 KWPB CONC. LP GROUND WIRE KWPB ELECTRIC KLP KWPB8 CONC. LP GROUND WIRE GMH MIN ELEC. ROOM 3 E-3 GVLVB KPST 7.98 KPST 7.90 KPST KPST 8.03 KPST KPST J G KPST8 7.9 KWPB ELECTRIC 8.08 KPST G KVLV WTER KVLV WTER KVLV WTER KVLV WTER 5 KVLV WTER PNEL HC-3,5,7 KVLV WTER TYPICL KVLV WTER KVLV WTER KVLV WTER E- E- GTBM X CUT G GVLVB G GVLVB GTBM X CUT REFER TO DRWING E-, GNGWY CONDUIT ROUTING ELEVTION DETILS FOR JUNCTION BOX (FUTURE CMER) LOCTIONS. KEYED NOTES: DISCONNECT JIB CRNE/CHIN HOIST. DE-ENERGIZE CIRCUIT ND REMOVE CONDUCTORS BCK TO SOURCE. REFER TO MIN ELECTRICL ROOM, DETIL 3/E-3 FOR SOURCE LOCTION ND DETIL /E-3 FOR PNEL SCHEDULE. PROPOSED NEW CHIN HOIST MOTOR ND SSOCITED CONTROLS, FURNISHED BY OTHERS ND INSTLLED BY ELECTRICL CONTRCTOR. COORDINTE EXCT LOCTION WITH STRUCTURL DRWINGS, PRIOR TO COMMENCEMENT OF WORK. 3 PROVIDE SURFCE MOUNTED RIGID GLVNIZED METL CONDUIT TO ND NEW GNGWY FOR NEW CHIN HOIST MOTOR. REFER TO PNEL SCHEDULE, DETIL /E-3 FOR CONDUIT ND CONDUCTOR SIZES. PROVIDE " SURFCE MOUNTED RIGID GLVNIZED METL CONDUIT WITH PULL CORD TO ND NEW GNGWY FOR FUTURE CMERS. PROPOSED CONDUIT ROUTING IS SHOWN ON DRWING E-, GNGWY CONDUIT ROUTING ELEVTION. ROUTING INDICTED IS FOR ILLUSTRTION PURPOSES. COORDINTE EXCT PTHWY ND ROUTING WITH BEST PRCTICES OF MENS ND METHODS. 5 PROVIDE SURFCE MOUNTED 6"x"x" GLVNIZED METL JUNCTION BOX TO NEW GNGWY FOR PROPOSED CMER(S). QUNTITIES ND LOCTIONS RE DEFINED ON DRWING E-, GNGWY CONDUIT ROUTING ELEVTION. DESCRIPTION BY PVD DO DO CHECKED BY: SJC PPROVED BY: JDC 078 Deerwood Park Blvd. South Jacksonville, Florida Certificate of uthorization No. 560 Engineer of Record: Stephen Conway, P.E. No.: 5353 JCKSONVILLE PORT UTHORITY DMES POINT MRINE TERMINL CRUISE ELECTRICL SITE PLN SHEET DTE CONTRCT NO. E- JULY 08 C-575 $USER$ $DTE$ $TIME$ $FILE$

20 GENERL NOTES: TO LOCL ELECTRIC UTILITY JE. LL ELECTRICL UIPMENT SHOWN ON THIS SHEET IS TO REMIN, UNLESS OTHERWISE NOTED. REFER TO PNELBORD SCHEDULE FOR DDITIONL INFORMTION. M PD MOUNTED TRNSFORMER KEYED NOTES: REFER TO PNELBORD SCHEDULE FOR DDITIONL INFORMTION, DETIL /E-3. REUSE 30/3P CIRCUIT BREKER.FOR NEW DEDICTED CIRCUIT FOR CHIN HOIST. REFER TO ELECTRICL SITE PLN FOR GNGWY LOCTION. STNDBY GENERTOR 80Y/77, 3Æ, W, 00KW/5KV G 600/3 MCB MIN ELEC. ROOM MIN DISTRIBUTION PNELBORD "MDP" BUS 80/77V - 3Æ - W 35 KIC /3 5/3 00/3 600/3 00/3 0/3 00/3 5/3 5/3 SPRE SPRE 00/3 TS 00-P WITH MINTENNCE BYPSS NO NC XFMR 75 KV: 80V: 08Y/0V, 3Æ, W 5 MLO PNEL H 600 MLO PNEL HB 5 MLO PNEL HC ELEC. ROOM CUSTOMS/INS. MIN ELEC. ROOM MIN ELEC. ROOM MIN ELEC. ROOM PUMP PCU- PUMP PCU- PNEL SH 80/77V - 3Æ - W 00/3 MCB TO DISTRIBUTION PNEL "DP" 75/3 TO DISTRIBUTION PNEL "SDP" XFMR.5 KV 80V: 08Y/0V, 3Æ, MIN ELEC. ROOM MIN ELEC. ROOM ELEC. ROOM CUSTOMS /INS DMES POINT MRINE TERMINL CRUISE E-3 JCKSONVILLE PORT UTHORITY MillerBE 7/0/08 :7:3 PM \\JXFILE0\Transportation\P\ DPMT Cruise Term

21 DMES POINT MRINE TERMINL CRUISE JCKSONVILLE PORT UTHORITY MillerBE 7/0/08 :7:3 PM \\JXFILE0\Transportation\P\ DPMT Cruise Term E-

22 DMES POINT MRINE TERMINL CRUISE JCKSONVILLE PORT UTHORITY MillerBE 7/0/08 :7:3 PM \\JXFILE0\Transportation\P\ DPMT Cruise Term

23 DMES POINT MRINE TERMINL CRUISE JCKSONVILLE PORT UTHORITY MillerBE 7/0/08 :7:3 PM \\JXFILE0\Transportation\P\ DPMT Cruise Term

C-TRAN MAINTENANCE BUILDING EXPANSION / SOUTH LOT IMPROVEMENTS

C-TRAN MAINTENANCE BUILDING EXPANSION / SOUTH LOT IMPROVEMENTS N HJ 5 C.DEFG B 5 7.B. 0. NOTES:. REFERENCE 5/S. FOR SITE LIGHT POLE S COORDINTE LOCTIONS WITH ELECTRICL SITE LIGHTING PLNS. 5 6 7 8 9 ' - 0" 5' - 0' - 0" 0' - 0" 0' - 0" 0' - 0" 0' - 0" 0' - 0" 0' - 0"

More information

[1200mm] 5" [125 mm] 2 3/4" [70mm] [2600mm] [450mm]

[1200mm] 5 [125 mm] 2 3/4 [70mm] [2600mm] [450mm] MIN 9'-10 1/2" [3010mm] 9'- CR 8'-6"MIN [2825mm] 6'-0" 12" S [2550mm] CR [1800mm] ON SIDE PLN "" 8'-8" CR 2 [2600mm] 6'-0" CR [1800mm] 2 FRONT ND RER S [55mm] 8'-6" [2550mm] [55mm] [125 mm] 2 [70mm] 6

More information

-- 3 S1006 3 S1006 REMOVE EXISTING CCESS HTCH ND PRT OF EXISTING SL FOR NEW CCESS HTCH SIZE 6060 3960 REMOVE EXISTING CONCRETE PD MXM 914x914 CCESS HTCH INSTLL S PER MNUFCTURERS INSTRUCTIONS 6060 3960

More information

STANDARD CONSTRUCTION DETAILS STORM DRAINAGE REVISED - MAY 2017 DEPARTMENT OF ENGINEERING

STANDARD CONSTRUCTION DETAILS STORM DRAINAGE REVISED - MAY 2017 DEPARTMENT OF ENGINEERING STNDRD CONSTRUCTION DETILS STORM DRINGE REVISED - MY 2017 DEPRTMENT OF ENGINEERING GENERL NOTES CONCRETE,SPHLT STREET REPIR,PIPE EDDING UTILITY SUPPORT,WTER MIN LOWERING,CONCRETE COLLR TYPE "" STORM SEWER

More information

POWER BUTTON: 25mm (1") CONDUIT X 3048mm (10'-0") LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD)

POWER BUTTON: 25mm (1) CONDUIT X 3048mm (10'-0) LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD) R Easy-aire GX PNEUMTIC DELIVERY SYSTEM 24mm(") DI. PNEUMTIC TUBE SYSTEM 86G OPERTOR ND 8G CUSTOMER DETILS L962 CLL -8-999-6 OPERTOR CONTROL PNEL PROJECTION FILE NO. 8-26 REV. SUBJECT TO CHNGE W ITHOUT

More information

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL SECTION 08316 WTERTIGHT IRTIGHT SPECIL CCESS DOORS & HTCHES, PRT 1 GENERL HIGHLIGHTED RES TO BE INSERTED BY SPECIFYING ENGINEER. 1.1 WORK OF THIS SECTION. THE WORK OF THIS SECTION INCLUDES PROVIDING LL

More information

SIDE DETAIL ELEVATION DETAIL JCM VIVA VISIO SYSTEM PRODUCT DATA -

SIDE DETAIL ELEVATION DETAIL JCM VIVA VISIO SYSTEM PRODUCT DATA - * UCP REQUIRED IF SYSTEM DOES NOT HVE HNDRIL OPTIONL CPS ) SS 'U' CP ) SS Ø" CP 3) SS Ø" LED CP ) Ø " OR Ø" SS HNDRIL ) Ø" WOOD HNDRIL CHERRY WOOD " GP (NOM) RED OK WHITE OK MPLE WOOD 3) Ø " LED iril 3'7"

More information

CREEK Technical Services, LLC

CREEK Technical Services, LLC Technicl Services, LLC Certificte of uthoriztion No. 29824 17520 Edinburgh Dr Tmp, FL 33647 (813) 480-3421 EVLUTION REPORT FLORID BUILDING CODE, 6 TH EDITION (2017) Mnufcturer: VRITILE INC. Issued ugust

More information

RETAINING BLOCKS Reinforcing Steel R-5236HC 52" (1,320 mm) Hollow Core Retaining Block

RETAINING BLOCKS Reinforcing Steel R-5236HC 52 (1,320 mm) Hollow Core Retaining Block RETAINING BLOCKS Reinforcing Steel R-5236HC 52" (1,320 mm) Hollow Core Retining Block A (Typ.) B (Typ.) 3D VIEW b 87 93 d d c A B BAR DIAGRAM BAR SCHEDULE DIMENSIONS BAR* b c d LENGTH/BAR NO. BARS TOTAL

More information

152mm (6") DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES:

152mm (6) DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES: 2mm ") DI. POINT TO POINT SYSTEM PVC OR STEEL SYSTEM L84 CLL -800--600 TYPE I ND TYPE II OVERHED UNITS 4 6 ") ( 8 ") 6 8 ") ( -0 PLN VIEW 20 (8 28 8 ") ( 8 ") 4 ( -4") 2 (4 ( 8 ") 28 ( 8 ") THE TYPE I

More information

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL SIDE CR FOR INSTLLTION NEXT TO DIEBOLD 00 - IN LOBBY TELLER (ILT) L2 CLL -800--600 CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

GENERAL NOTE: GRADE 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P2. 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P1.

GENERAL NOTE: GRADE 4-#8 AND 1-#8 EGC IN 1 CONDUIT TO POLE P2. 4-#8 AND 1-#8 EGC IN 1 CONDUIT TO POLE P1. ll reproduction + intellectual property rights reserved by rchitecture Incorporated TOP SSEMBLY WIRE HRNESS (INSE ) CONCRETE RISER NOTES: PNL SFL EXISTING NOVEC TRNSFORMER (V SECONDRY) TO REMIN. EXISTING

More information

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 L2 CLL -800--600 TP-826-00. R CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE DIEBOLD 00 - IN LOBBY TELLER (ILT) PORTRIT OR LNDSCPE

More information

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL 00 IN LOBBY TELLER - (ILT) PORTRIT ND L CLL -800--600 40mm ( 6") CEN I / CEN III GS / CEN IV GS SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND

More information

HYDRANT & GATE VALVE INSTALLATION

HYDRANT & GATE VALVE INSTALLATION HYDRNT FLG TO BE INSTLLED ON THE NOZZLE SECTION 5' TYPICL (3' MINIMUM) HYDRNT, CLOW MEDLLION 1.0' HYDRNT STEMER KIT - 4.5" NH - 5" STORZ METL FCE DPTER WITH STORZ CP. IF OPTIONL LOCKING CP IS DESIRED,

More information

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS R DIEBOLD 00 LOBBY CSH RECYCLER- RER LOD L2 CLL -0--600 64 SFE (2 6 ") 40mm ( 6") CEN I SFE - " DISPLY OR " DISPLY WITH DETILS FOR OPTIONL VESTIBULE INSTLLTION CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH

More information

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15

330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15 L CLL -800--600 R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL 0mm ( 6" ) CEN I, CEN III GS, or CEN IV GS SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

CASEMENT - LARGE MISSILE IMPACT

CASEMENT - LARGE MISSILE IMPACT CSEMENT - LRGE MISSILE IMPCT 1/4" MX. O.. FLNGE WIDTH 7" MX. UNIT WIDTH 6 1/4" MX. SSH WIDTH 1 /4" GLSS DLO GENERL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED ND MNUFCTURED TO COMPLY WITH THE FLORID

More information

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15 DISPLAY OR 19 DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER- FRONT LOD " DISPLY OR " DISPLY CEN I, CEN III GS, CEN IV GS or CEN IV GS EX SFES CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL

More information

RICHARDSON AVENUE STREET IMPROVEMENT PROJECT RICHARDSON AVENUE STREET IMPROVEMENT PROJECT

RICHARDSON AVENUE STREET IMPROVEMENT PROJECT RICHARDSON AVENUE STREET IMPROVEMENT PROJECT LOCTED WITHIN THE RICHRDSON VENUE RIGHT--WY FROM ND INCLUDING THE U.S HIGHWY 60/285 INTERSECTION SOUTH TO SECOND STREET,, LMOS COUNTY, COLORDO. PRIL 25, 206 U.S. HIGHWY 60/285 PROJECT LOCTION VICINITY

More information

SHEET 1 OF 6

SHEET 1 OF 6 REVISIONS REV DESCRIPTION CHG.NO. PP'D DTE SENSOR WELD NECK MOUNTING FLNGE & WELD FTG. (FCTORY WELDED) VILBLE IN SME B16.5 RF & RTJ, ND EN 1092-1 RF. REFER TO TBLE 1 ON SHEET 2 OR FOR S ND DIMENSIONS NEW

More information

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19" DISPLAY FRONT ELEVATION

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15 DISPLAY OR 19 DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19 DISPLAY FRONT ELEVATION R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER- FRONT LOD " DISPLY OR " DISPLY WITH mm ( ") UL SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE

More information

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2") UL SAFE - 15" OR 19" DISPLAY THROUGH THE WALL 330mm (13") PLAN VIEW FRONT ELEVATION SECTION

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2) UL SAFE - 15 OR 19 DISPLAY THROUGH THE WALL 330mm (13) PLAN VIEW FRONT ELEVATION SECTION L8 CLL -800--600 R DIEBOLD 0 CSH RECYCLER TERMINL mm ( ") UL SFE - " OR " DISPLY THROUGH THE WLL 0mm (") 64 SFE ( 6 ") CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

GREGORY RD PROPERTY LINE (PPROX.) LEGEND LIGHTING CONTROL CENTER 50W METL HLIDE FLOODLIGHT GROUND MOUNTED JUNCTION BOX PROPERTY LINE (PPROX.) UNDERGROUND CONDUIT WITH CONDUCTOR, SIZE S SHOWN. 50W METL

More information

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL L CLL -800--600 CS 80 FULL FUNCTION DRIVE-UP TERMINL mm ( ") UL - "or " DISPLY THROUGH 0mm (8") MXIMUM WLL CONSULT WITH DIEBOLD NIXDORF INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE

More information

AGNES SCOTT OBSERVATORY - SOLAR

AGNES SCOTT OBSERVATORY - SOLAR GNES SCOTT OBSERVTORY - SOLR ELECTRICL NOTES ELECTRICL REQUIREME PV SYSTEM NOTES Roof-Mounted Installation 6kW W N S E MTERILS ND METHODS REVISION NUMBER - FOR CONSTRUCTION REVISION HISTORY DESCRIPTION

More information

ABB industrial drives. Mechanical installation instructions ACS880 multidrive cabinets

ABB industrial drives. Mechanical installation instructions ACS880 multidrive cabinets ABB industril drives Mechnicl instlltion instructions ACS880 multidrive cbinets List of relted mnuls Generl drive mnuls (in ll deliveries) Electricl plnning instructions for ACS880 multidrive cbinets nd

More information

203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

203mm (8) MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8) MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY L0 CLL -800--600 R CS 0 FULL FUNCTION VESTIBULE TERMINL " OR " DISPLY-THROUGH 0mm ( MXIMUM WLL 40mm ( 6") CEN I, CEN III GS or CEN IV GS SFES SFE ( 6 ") CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR

More information

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY L08 CLL -800--600 R CS 0 FULL FUNCTION TERMINL " OR " DISPLY - THROUGH THE WLL 0mm (") 40mm ( 6") CEN I, CEN III GS OR CEN IV GS SFES SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS

More information

S»'94**gres* 6,=4.4.0 R\OF e.. S Z * 0 10.,5251, *S .//0/1111\\\\\\ VIWINCO INC. S-SERIES IMPACT AW/FIX STACKED 04/13/12

S»'94**gres* 6,=4.4.0 R\OF e.. S Z * 0 10.,5251, *S .//0/1111\\\\\\ VIWINCO INC. S-SERIES IMPACT AW/FIX STACKED 04/13/12 ISIONS DTE 07/27/5 ISED INSTLLTION DETILS RL THE PRODUCT SHOWIN HEREIN IS DESIGNED ND MNUFCTURED TO COMPLY WITH REQUIREME OF THE FLORID UILDING CODE 2 WOOD FRMING ND MSONRY OPENIING TO E DESIGNED l\id

More information

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16") CEN I, CEN III GAS or CEN IV GAS SAFES

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16) CEN I, CEN III GAS or CEN IV GAS SAFES L STNDRD ND FULL HEIGHT - RER LOD - WITH 0mm ( 6") "LL DIMENSIONS ND DESIGN CRITERI PGE OF 8 FRONT - STNDRD HEIGHT SEE PGES and FOR CS 00 STNDRD HEIGHT DETILS FRONT - FULL HEIGHT SEE PGES and FOR CS 00

More information

CS 7750 FULL FUNCTION TERMINAL 15" OR 19" DISPLAY - THROUGH THE WALL 330mm (13")

CS 7750 FULL FUNCTION TERMINAL 15 OR 19 DISPLAY - THROUGH THE WALL 330mm (13) L08 CLL -800--600 " OR " DISPLY - THROUGH THE WLL 0mm (") 40mm ( 6") CEN I CONSULT WITH DIEBOLD NIXDORF INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

SAN ANTONIO RIVER AUTHORITY

SAN ANTONIO RIVER AUTHORITY SN NTONIO RIVER UTHORITY DM OPERTIONS CENTER LOCTION MP PROJECT LOCTION BORD OF DIRECTORS DRRELL T. BROWNLOW, Ph.D. JIM CMPBELL LICI LOTT COWLEY JOHN FLIELLER JMES FULLER LOURDES GLVN JERRY G. GONZLES

More information

HOOK UP LAYOUT FOR HEAT GENERATION AND FUEL TANK SYSTEM

HOOK UP LAYOUT FOR HEAT GENERATION AND FUEL TANK SYSTEM HOOK UP LYOUT FOR HET GENERTION ND FUEL TNK SYSTEM DESRIPTION IRNIN PETROLEUM STNDRDS NO REVISION PERMITTED UNLESS PPROVED Y STNDRD ORGNIZTION OVER SHEET DRWING No. IPS-D-R-018 SHT 1 "(DN0) FILL FUEL OIL

More information

OPTIONAL 178mm (7") SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6") 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT

OPTIONAL 178mm (7) SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6) 330mm (13) MAXIMUM WALL THICKNESS IN AREA OF UNIT L88 CLL -0--600 R DIEBOLD 0 CSH RECYCLER WITH COIN 40mm ( 6") CEN I, CEN III GS or CEN IV GS SFES THROUGH 0mm (") MXIMUM WLL 64 SFE CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND

More information

3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2) UL SAFE - 15 DISPLAY OR 19 DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER RER LOD mm ( ") UL SFE - " DISPLY OR " DISPLY WITH DETILS FOR OPTIONL VESTIBULE INSTLLTION CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR

More information

R3( )RS: CALL OUT LAMPS FOR MURALS. EXISTING THEATRE REMOVE AND DISCARD CHANNEL LETTERS WITH NEON ILLUMINATION

R3( )RS: CALL OUT LAMPS FOR MURALS. EXISTING THEATRE REMOVE AND DISCARD CHANNEL LETTERS WITH NEON ILLUMINATION RSN 688469 1 of 10 DEIE MOLTZ pproval / Revision / R1 (9-6-1)RS: SPRED OUT SPCING ITEM, MOVE EXISTING THETRE ERIL PHOTO - PLN VIEW OF EXISTING THETRE N.T.S. N.T.S. R4(10-18-1)RS: ENLRGE ITEM TO STD. SIZE.

More information

450DIA STATION BY-PASS CONNECTION c/w 450DIA KNIFE GATE ISOLATION VALVE AND BLIND FLANGE C.L. OF PUMP REMOVAL MONORAIL BEAM OPENING ABOVE

450DIA STATION BY-PASS CONNECTION c/w 450DIA KNIFE GATE ISOLATION VALVE AND BLIND FLANGE C.L. OF PUMP REMOVAL MONORAIL BEAM OPENING ABOVE 3 87.43 m 3 P7 P7 3 VIC COUPLING (TYP. 6) PRESSURE INDICTOR c/w ISOLTION VLVE T SPRINGLINE ND 5DI DRIN ND VLVE T INVERT (TYP.3) 45DI STTION Y-PSS CONNECTION c/w 45DI KNIFE GTE ISOLTION VLVE ND LIND FLNGE

More information

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13") MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13) MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS L0 CLL -800--600 R DIEBOLD 0 CSH DISPENSER THROUGH 0mm (") MXIMUM WLL mm ( " ) UL CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR DDITIONL DETILS ND INFORMTION. PLESE SEE PLNNING ND SITE PREPRTION GUIDE

More information

RIDEAU STREET AT WALLER STREET INTERSECTION WIDENING

RIDEAU STREET AT WALLER STREET INTERSECTION WIDENING DRWING FRME: 790mm x 53mm City of Ottawa 2011 INFRSTRUCTURE SERVICES DEPRTMENT OTTW RIVER CONTRCT SITE GENERL MNGER INFRSTRUCTURE SERVICES DEPRTMENT PRESTON STREET BRONSON VENUE WELLINGTON STREET BNK STREET

More information

{ CONST GAS { CONST. R/W Line JOHNS LAKE CONSERVATION AREA { CONST. R/W Line 99.

{ CONST GAS { CONST. R/W Line JOHNS LAKE CONSERVATION AREA { CONST. R/W Line 99. 1 0 1 Regular Exc. Embankment V V 105 TEMP. PILE WLL 105 JOHNS LKE CONSERVTION RE ORNGE CO. BOCC Construction 1:4.25.32 Construction PROP. 24" SRCP 39+00.00 WM NPW 39+00.00 TEMP. PILE WLL TEMP. HEDWLL

More information

A battery of 19 Rectangular Portal Culverts under a major road. Rectangular Portal Culvert used as an inclined mine shaft.

A battery of 19 Rectangular Portal Culverts under a major road. Rectangular Portal Culvert used as an inclined mine shaft. 9 A bttery of 19 Rectngulr Portl Culverts under mjor rod. Rectngulr Portl Culvert used s n inclined mine shft. Rectngulr Portl Culverts with Spigot nd Socket Pipes. Rectngulr Portl Culvert with in-situ

More information

S DRAWING DOES NOT APPLY TO CONNECTIONS TO LINED PIPE A 6" VCP DOUBLE " Y " BRANCH ARD " T " SADDLE WITH DOUBLE " Y " SADDLE WITH SHORT RADIUS BEND

S DRAWING DOES NOT APPLY TO CONNECTIONS TO LINED PIPE A 6 VCP DOUBLE  Y  BRANCH ARD  T  SADDLE WITH DOUBLE  Y  SADDLE WITH SHORT RADIUS BEND 6" VCP DOULE " Y " RNCH PLUG LL RNCHES NOT CONNECTED NOTE: HOLES IN EXISTING PIPE SHLL E MDE Y CORE DRILLING PER S-a-86. 4" 18" 6" 6" VCP " T " SDDLE PER S-a-213 C GROUND SURFCE 8' MIN SEE NOTE EXISTING

More information

CCS-810 KIT SERIES INSTRUCTION SHEET

CCS-810 KIT SERIES INSTRUCTION SHEET (COMPLETE KIT ILLUSTRTED. CUT-OUTS IN TRCK & FSCI TO EXPOSE COMPONENTS) CCS-810 KIT SERIES INSTRUCTION SHEET CROWDERTRCK S CTCH N CLOSE TM SYSTEM PREVENTS BOUNCING ND SLMMING OF SLIDING DOORS. CN BE INSTLLED

More information

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2) UL SAFE - 15 DISPLAY OR 19 DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION R L CLL -0--600 64 SFE ( 6 ") DIEBOLD 00 LOBBY CSH RECYCLER RER LOD mm ( ") UL SFE - " DISPLY OR " DISPLY WITH DETILS FOR OPTIONL VESTIBULE INSTLLTION CONSULT WITH DIEBOLD INSTLLTION/SERVICE BRNCH FOR

More information

6'R 2'-4" 5'RR 5-4"'

6'R 2'-4 5'RR 5-4' 24'R 1'-3" INLET 24'R 1'-3" 24'R 1'-3" INLET 5'R 5' 5'R 4'/INLET REVISION HISTORY REV. DESCRIPTION DTE ECO BY RELESED FOR QUOTE RHOUSTON B DDED DIGS MWILLIMS 11 MIRROR NUMBER: MDE FROM: CHECK IN DTE/TIME:

More information

Special School District of South County North County Technical High School Welding Lab Renovation 1700 Derhake Road St. Louis, Missouri 63033

Special School District of South County North County Technical High School Welding Lab Renovation 1700 Derhake Road St. Louis, Missouri 63033 Specil School District of South County North County Technicl High School Welding L Renovtion 00 Derhke Rod St. Louis, Missouri 6 DDENDUM # Dte: Mrch, Prepred For: Specil School District of St. Louis County

More information

6. BUILDER / CONTRACTOR RESPONSIBILITIES

6. BUILDER / CONTRACTOR RESPONSIBILITIES CUSTOMER INORMTION CUSTOMER NME: DDRESS: PROJECT NME: PROJECT LOCTION: GENERL NOTES. MTERILS 2. DESIGN 5. STRUCTURL PRIMER HNGR STRUCTURL STEEL PLTE LNGE MTERIL COLD ORMED LIGHT GUGE SHPES STRUCTURL CBLES

More information

THE OHIO TURNPIKE ND INFRSTRUCTURE COMMISSION JMES W. SHOCKNESSY OHIO TURNPIKE OHIO TURNPIKE ND INFRSTRUCTURE STNDRD DRWINGS S- CB- CB-2 CB-3 CB-4 CB-5 09-9-8 09-9-8 09-9-8 CBR- CBR-2 CBR-3 06-25-07 09-9-8

More information

631 ALLOWANES AND TOLERANCES

631 ALLOWANES AND TOLERANCES 631 ALLOWANES AND TOLERANCES ANSI Fits. Tbles 3 through 9 inclusive show series of stndrd types nd clsses of fits on unilterl hole bsis, such tht the fit produced by mting prts in ny one clss will produce

More information

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007 Directionl Control Vlves Solenoid Operted with 8W Coil RPEA3-06 0/20 Size 06 (D 03) 350 br (5076 PSI) 80 L/min (2 GPM) Replces 2/2007 /3-, /2- wy directionl control vlves Enclosure type to IP65 Push button

More information

LU-0515ASC. ALUMINUM 5 ROW x 15'-0" - UNIVERSAL SERIES MODEL CS.1 OPTIONS: -RB = RUBBER BUMPERS -MS = MUD SILLS 6" RISE / 12" SEAT 5 ROW BLEACHER

LU-0515ASC. ALUMINUM 5 ROW x 15'-0 - UNIVERSAL SERIES MODEL CS.1 OPTIONS: -RB = RUBBER BUMPERS -MS = MUD SILLS 6 RISE / 12 SEAT 5 ROW BLEACHER LUMINUM 5 OW x 5'-0" - UNIVESL SEIES MODEL OPTIONS: -B = UBBE BUMPES -MS = MUD SILLS 4/4/07 CS. OPTIONL -MS (MUD SILL) OPTIONL -B (UBBE BUMPE) COVE SHEET 80 Sydney oad 80 Sydney oad 5'-0" '-6" TYP. OVEHNG

More information

Print This Page. Return To Index

Print This Page. Return To Index PLASTI-BOND REDH2OT KNOCKOUT HUBS KNOCKOUT HUBS PRST2 PRSTG2 Knockout Hubs Specifictions Knockout Hubs Configurtions ST STG2 b c STTB STTTB d COMPLIANCES PLASTI-BOND REDH 2 OT ST style knockout hubs re

More information

INSTALLATION GUIDE INSTALLATION GUIDE

INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE INSTALLATION GUIDE CONTACT US By selecting Hiku fn, you ve chosen qulity design, heightened comfort nd effortless conservtion. Use this guide to sfely instll your fn. Plese contct us

More information

Cable Trolleys for C-Rails Program

Cable Trolleys for C-Rails Program Cble Trolleys for C-Rils Progrm 02 0 0260 Contents C-Ril nd Accessories Progrm 02 C-Ril x... 2 Trck Coupler... 2 End Stop... 2 Trck Support Brcket... 2 Support Arm nd Girder Clip... 3 Brcket... 3 Cble

More information

Central Purchasing 213 South Oliver Drive Aztec, New Mexico (505) Bid No , McGee Park Pavilion. County Executive Office

Central Purchasing 213 South Oliver Drive Aztec, New Mexico (505) Bid No , McGee Park Pavilion. County Executive Office Central Purchasing 13 South Oliver Drive ztec, New Mexico 87410 (505) 334-4551 Bid No. 16-17-17, Mcee Park Pavilion County Executive Office DDENDUM # May 5, 017 CHNES / CLRIFICTION / DDITIONL INFORMTION

More information

CCD-493 KIT SERIES INSTRUCTION SHEET

CCD-493 KIT SERIES INSTRUCTION SHEET (COMPLETE CCD-493-W KIT ILLUSTRTED. CUT-OUTS IN TRCK TO EXPOSE COMPONENTS) CCD-493 KIT SERIES INSTRUCTION SHEET CROWDERTRCK S CTCH N CLOSE TM SYSTEM PREVENTS BOUNCING ND SLMMING OF SLIDING S. CN BE INSTLLED

More information

FOREWORD UNIFORM STANDARD DRAWINGS FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS, CLARK COUNTY AREA, NEVADA

FOREWORD UNIFORM STANDARD DRAWINGS FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS, CLARK COUNTY AREA, NEVADA FOREWORD FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS,, NEVD The following participating entities of the Clark County, Nevada area have adopted these standard drawings. CITY OF LS VEGS dopted by

More information

SECTION BITUMINOUS CONCRETE PAVING AND ATHLETIC SURFACING. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION BITUMINOUS CONCRETE PAVING AND ATHLETIC SURFACING. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SETION 321800 ITUMINOUS ONRETE PVING ND THLETI SURFING PRT 1 GENERL 1.01 GENERL REQUIREMENTS PRT nd DIVISION 1 of PRT re hereby mde prt of this SETION. Exmine ll conditions s they exist t the project prior

More information

tel. +44 (0) 28 37 518111 fx +44 (0) 28 37 528181 e.mil sles@technidrive.co.uk points for considertion when shft mounting direct drive ger units. modern hollow bore output hub ger units lend themselves

More information

FOREWORD UNIFORM STANDARD DRAWINGS FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS, CLARK COUNTY AREA, NEVADA

FOREWORD UNIFORM STANDARD DRAWINGS FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS, CLARK COUNTY AREA, NEVADA FOREWORD FOR PUBLIC WORKS' CONSTRUCTION, OFFSITE IMPROVEMENTS,, NEVD The following participating entities of the Clark County, Nevada area have adopted these standard drawings. CITY OF LS VEGS dopted by

More information

DETAIL - FACADE SCREEN

DETAIL - FACADE SCREEN C D E general notes: ll dimensions are given in millimeters, unless otherwise specified. 0_DD Do not scale drawings. ll dimensions to be verified on site before construction commences. 9 Contractors to

More information

MISCELLANEOUS INDEX PAGE DATE SERIES DESCRIPTION

MISCELLANEOUS INDEX PAGE DATE SERIES DESCRIPTION MISCELLNEOUS INDEX 08/01/11 PGE DTE SERIES DESCRIPTION M-1 08/01/11 Miscellaneous Index M-2 04/16/96 M01 Tooling all M-3 04/16/96 M02 Scrap Chute Hook and Retainer racket M-4 01/03/95 M03 Scrap Chute Chain

More information

Spring Return DuraDrive Two-Position Actuator

Spring Return DuraDrive Two-Position Actuator MA40-704x Series, MA4-707x Series, nd MA4-75x Series Spring Return DurDrive Two-Position Actutor For spring return pplictions tht require twoposition control of dmpers nd vlves in HVAC system. Fetures:

More information

EASTERN WATER RECLAMATION FACILITY SECONDARY CLARIFIERS 1, 2, 3 AND 4 IMPROVEMENTS

EASTERN WATER RECLAMATION FACILITY SECONDARY CLARIFIERS 1, 2, 3 AND 4 IMPROVEMENTS CONSTRUCTION DRWINGS FOR ESTERN WTER RECLMTION FCILITY CLRIFIERS,, ND IMPROVEMENTS DISTRICT January 0 CPITL PROJECT No. 8 PROJECT SEQUENCE No. ORNGE COUNTY MYOR TERES JCOBS BORD OF COUNTY COMMISSIONERS

More information

PIPE SUPPORTS IRANIAN PETROLEUM STANDARDS COVER SHEET B A REV. DRAWING No. DATE DATE IPS-D-AR-012 DESCRIPTION

PIPE SUPPORTS IRANIAN PETROLEUM STANDARDS COVER SHEET B A REV. DRAWING No. DATE DATE IPS-D-AR-012 DESCRIPTION SUPPORTS DESRIPTION IRNIN PETROLEUM STNDRDS NO REVISION PERMITTED UNLESS PPROVED Y STNDRD ORGNIZTION OVER SHEET DRWING No. IPS-D-R-0 SHT ONRETE JOISTS STEEL JOISTS WOOD JOISTS NOTE: STRUTURL STEEL EM SEE

More information

ALUMINUM ENTRANCE DOORS

ALUMINUM ENTRANCE DOORS DOORS REVISION SHEET DESRIPTION 1 - GENERL NOTES & GLZING DETIL 2 - ELEVTIONS, NHOR LYOUT & ONFIGURTIONS 3 ELEVTIONS, NHOR LYOUT & ONFIGURTIONS - - VERTIL DETILS - HED & SILL OPTIONS 2. DEQUY OF THE EXISTING

More information

TC/American Product Catalog

TC/American Product Catalog CONTENTS Table of Contents -5 Rail Index B-1 Suspension Index C-1 Switches and Curves Index D-1 Trolleys Index E-1 Cranes Index F-1 End Trucks Index G-1 Drivetractors and Motorized Trolleys Index H-1 Electrification

More information

Electric underground service installation requirements

Electric underground service installation requirements MRCH 0 Electric underground service installation requirements CLL PSE S CUSTOMER CONSTRUCTION S T -888--9 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMTION. Builder/owner/developer responsibilities

More information

CONTROL VALVES FOR GRINDER. Installation, Maintenance and Operating Instructions 5 GA 71 en Issue 5/02

CONTROL VALVES FOR GRINDER. Installation, Maintenance and Operating Instructions 5 GA 71 en Issue 5/02 CONTROL VALVES FOR GRINDER Instlltion, Mintennce nd Operting Instructions 5 GA 71 en Issue 5/02 2 Tble of Contents 1 OPERATION......................... 3 1.1 Generl......................... 3 1.2 Min components.................

More information

SSAB Water mains PIPES AND FITTINGS

SSAB Water mains PIPES AND FITTINGS SSAB Wter mins PIPES AND FITTINGS Pipes nd fittings mnufctured y SSAB re used primrily with wter pipeline sizes DN 400-1200. The fittings re mde of steel pressure pipes (ex works delivery) nd cn e coted

More information

The widest range to provide the optimum tailor made solutions to your fume and gas extraction needs.

The widest range to provide the optimum tailor made solutions to your fume and gas extraction needs. FUME XTRACTION ARMS Improving your workspce Chemicl resistnt Antisttic Stndrd FX ARMS The widest rnge to provide the optimum tilor mde solutions to your fume nd gs extrction needs. Avilble in Stndrd, Antisttic

More information

CC-410 KIT SERIES INSTRUCTION SHEET

CC-410 KIT SERIES INSTRUCTION SHEET (COMPLETE CC-410-W KIT ILLUSTRTED. CUT-OUTS IN TRCK & FSCI TO EXPOSE COMPONENTS) CC-410 KIT SERIES INSTRUCTION SHEET CROWDERTRCK S CTCH N CLOSE TM SYSTEM PREVENTS BOUNCING ND SLMG OF SLIDING DOORS. CN

More information

IGNITION SYSTEM SERVICE MANUAL NUMBER

IGNITION SYSTEM SERVICE MANUAL NUMBER IGNITION SYSTEM SERVICE MANUAL NUMBER 26 Specifictions Timing Timing (At Idle rpm) 1 1 BTDC 2 / 1 ATDC 3 / 2 ATDC 4 1 Timing must be set using specil procedure s outlined in this section. Timing cnnot

More information

HAMPTON INN AND SUITES

HAMPTON INN AND SUITES SUITES, /7/08 5:0:0 PM Z:\808 Montpelier Garage\0. REVIT FILES\808 - Montpelier Parking Garage - 0--8.rvt ADD ADDITIONAL A/C AIR CONDITION(ING) AT ACOUSTIC TILE ADJ ADJUSTABLE AFF ALUM ABOVE FINISH FLOOR

More information

Arcadia ssembly Instructions. 501x363x242cm / 16 5"Lx11 103/4"x7 111/4"

Arcadia ssembly Instructions. 501x363x242cm / 16 5Lx11 103/4x7 111/4 A ssemly Instructions Arcdi 5000 English_71087 501x36342cm / 16 5"Lx11 103/4"x7 111/4" Compny informtion: Plrm Americs Inc. 9735 Commerce Prkwy Kutztown, PA, USA Service Center: Toll Free: (877) 627-8476

More information

EVA II - ELECTRONIC VAULT ATTENDANT SYSTEM PERSPECTIVE TOP VIEW FRONT VIEW EVA II - TOUCH SCREEN KIOSK EVA II - WIRING DIAGRAM PAGE 1 OF 6

EVA II - ELECTRONIC VAULT ATTENDANT SYSTEM PERSPECTIVE TOP VIEW FRONT VIEW EVA II - TOUCH SCREEN KIOSK EVA II - WIRING DIAGRAM PAGE 1 OF 6 R EV II - ELECTRONIC VULT TTENDNT SYSTEM L75 CLL -8-999-6 28 ( 8") (DIMENSIONS IN FEET-INCHES) 248 (9 286 ( TO VIEW ERSECTIVE "LL DIMENSIONS ND DESIGN CRITERI ROJECTION GE OF 6 SUBJECT TO CHNGE W ITHOUT

More information

TOP CAP KNOCK-OUTS FOR

TOP CAP KNOCK-OUTS FOR 2 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP.. VISIT OUR ON-LINE CTLOG T WWW.PNDUIT.COM FOR LIST OF CURRENT PRTS PPLICLE FOR TOP CP

More information

FUEL SYSTEM. Section 3A Pulse Crankcase Driven Fuel Pump. Model 200/225 DFI. 1. Fuel Pressure/Vacuum Gauge (0-15 psi) (Obtain Locally)

FUEL SYSTEM. Section 3A Pulse Crankcase Driven Fuel Pump. Model 200/225 DFI. 1. Fuel Pressure/Vacuum Gauge (0-15 psi) (Obtain Locally) FUEL SYSTEM Section 3A Pulse Crnkcse Driven Fuel Pump Tle of Contents Specifictions................................ 3A-1 Specil Tools................................ 3A-1 Fuel Pump..................................

More information

NET-ACCESS S TYPE VED READY CABINET 600mm WIDE X 1200mm DEEP FAMILY 12V343ST-DC VED TOP CAP FRONT PERFORATED SINGLE HINGE DOOR SPLIT SIDE PANEL

NET-ACCESS S TYPE VED READY CABINET 600mm WIDE X 1200mm DEEP FAMILY 12V343ST-DC VED TOP CAP FRONT PERFORATED SINGLE HINGE DOOR SPLIT SIDE PANEL THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. PNEL VED TOP CP PERFORTED SINGLE HINGE PNEL SOLID RER NET-CCESS S TYPE VED REDY CINET 600mm

More information

Exhaust System. Table of Contents. Section 7A - General Information. General Information

Exhaust System. Table of Contents. Section 7A - General Information. General Information Exhust System Generl Informtion Tle of Contents Section 7A - Generl Informtion Generl Informtion All Models... 7A-2 Exhust System Notice...7A-2 Reference Note...7A-2 Exhust System Connections...7A-2 Through

More information

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP.

THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. SIDE PNEL 2 TOP CP PERFORTED SINGLE HINGE KNOCK-OUTS FOR PDU POWER CORD SIDE PNEL RER PERFORTED

More information

DRIVE SHAFTS INDEX

DRIVE SHAFTS INDEX DRIVE SHAFTS 8 70237 Tble of Contents Pge Specifictions............................... 8-1 Torque Specifictions..................... 8-1 Specil Tools............................ 8-1 Lubricnts, Selnts,

More information

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE

13V399AN-DC DRAWN BY DATE CHK SCALE SIZE THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. TOP CP 2 KNOCK-OUTS FOR PDU POWER CORD PERFORTED SINGLE HINGE SPLIT DOOR SIDE PNEL IN SOME

More information

MNPV6 REV A DISCO 4X FINAL ASSY

MNPV6 REV A DISCO 4X FINAL ASSY NOTES 1) ITEM 2,USR, MUST HVE TWO END SCREWS REMOVED, SO THT ITEM, WHITE INSULTORS, CN E INSTLLED. 2) UNIT SHIPS WITH THE FOLLWING ECH LCK TWO WIRE STRIN RELIEFS, P/N 9--1 ECH LCK STRIN RELIEF NUTS, P/N

More information

WAVE SPRINGS SPECIFICATION FORM

WAVE SPRINGS SPECIFICATION FORM WVE SPRINGS SPECIFICTION FORM LOD Equal Deflection and Load LOD Reduced Operating Height REDUX TM Wave Spring Coil Spring RDIL WLL FREE HEIGHT WIRE THICKNESS OPERTES IN HOLE DIMETER CLERS ROD DIMETER TURNS

More information

POWER TRIM. Table of Contents. Section 5D - Auto Trim II

POWER TRIM. Table of Contents. Section 5D - Auto Trim II SERVICE MANUAL NUMBER 14 Tble of Contents POWER TRIM Section 5D - Auto Trim II AUTO TRIM II 1 B Auto Trim II System................. 5D-2 Description...................... 5D-2 Auto Trim II Opertion...............

More information

LIGHTING CONSTRUCTION MANUAL CONTROL WIRING

LIGHTING CONSTRUCTION MANUAL CONTROL WIRING CONSTRUCTION MNUL CONTROL WIRING Back to MIN INDEX Go to SECTION INDEX TYPE DESCRIPTION PGE TYPE DESCRIPTION PGE Zellweger Streetlight Relay Bo Layout & Wiring Details 33 Streetlight Contactor Bo Layout

More information

POWER TRIM. Table of Contents. Section 5D - Auto Trim II

POWER TRIM. Table of Contents. Section 5D - Auto Trim II SERVICE MANUAL NUMBER 11 Tble of Contents POWER TRIM Section 5D - Auto Trim II AUTO TRIM II Auto Trim II System................... 5D-2 Description........................ 5D-2 Auto Trim II Opertion.................

More information

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE D0D/6 THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP. 0 5/4/8 SPLIT SIDE PNEL JGC TOP CP CURVED PERFORTED SINGLE HINGE DOOR SPLIT SIDE PNEL

More information

CITY OF TAKOMA PARK, MARYLAND

CITY OF TAKOMA PARK, MARYLAND , MRYLN IORETENTION FCILITY WITH ( OPTION-2) IORETENTION WITH OVERFLOW RINGE SYSTEM TITLE N GENERL NOTES NTS Sept 8,207 RWING SW- No. IORETENTION FCILITY WITH ( OPTION-2) NTS TITLE N GENERL NOTES PPROVE

More information

CFX ITS Design Standards

CFX ITS Design Standards CFX ITS Design Standards ITS DESIGN STNDRDS FOR DESIGN, CONSTRUCTION, MINTENNCE ND UTILITY OPERTIONS ON THE STTE HIGHWY SYSTEM VERSION MRCH 208 494 ORL Tower Rd Orlando, FL 3280 PHONE NUMBER: 40-690-5000

More information

SECTION A-A

SECTION A-A 40.08 D 8 6 5 4 3 2 1 WRNING: IF THERE RE NY DISCREPNCIES ETWEEN THE CD FILE ND THE DRWING, THE DRWING WILL TKE PRECEDENCE. IF IN DOUT, SK. D C 51.1 48 20.25 18 C 23.68 15.12 NOTE: DRWER UNIT NOT INCLUDED,

More information

Series 250 Type and Type Pneumatic Control Valves Type 3251 Globe Valve

Series 250 Type and Type Pneumatic Control Valves Type 3251 Globe Valve Series 250 Type 3251-1 nd Type 3251-7 Pneumtic Control Vlves Type 3251 Globe Vlve DIN version Appliction Control vlve for process engineering pplictions with high industril requirements Nominl size DN

More information

TYPICAL ELEVATION VIEW

TYPICAL ELEVATION VIEW 22.2 STNDRD PNEL PRT LIST PRODUCT LENGTH WEIGHT * TUFBRRIER 95.5" PNEL 2426 mm [95.5"] 7.7 kg [7 lbs] TUFBRRIER 9.5" PNEL 3035 mm [9.5"] 9.7 kg [2.3 lbs] TUFBRRIER 43.5" PNEL 3645 mm [43.5"].6 kg [25.6

More information

Job Sheet 3. Pump Installation OBJECTIVE PROCEDURE. Installation of the Motor and Centrifugal Pump on the Pump Universal Base

Job Sheet 3. Pump Installation OBJECTIVE PROCEDURE. Installation of the Motor and Centrifugal Pump on the Pump Universal Base Job Sheet 3 Pump Instlltion OBJECTIVE To instll pump, perform shft lignment, nd instll coupling. PROCEDURE Before proceeding with this job, complete the sfety check list in Appendix B. Instlltion of the

More information

GUARDIAN VERTICAL MOUNTING

GUARDIAN VERTICAL MOUNTING GUARDIAN VERTICAL MOUNTING L120 GUARDIAN INDUSTRIAL & ATEX Exi VERTICAL REED LEVEL SWITCH This rnge of mgnet operted reed switches re equipped with hermeticlly seled reed contcts. The flot is fitted with

More information

PROPOSED BUILDING PLINTH AREA sq.m.

PROPOSED BUILDING PLINTH AREA sq.m. N 2028 PROPOSED BUILDING PLINTH RE 168.71 sq.m. 8585 610 2911 TO BE 1934 DTE 4556 3499 2269 2846 13972 10853 12293 15701 9044 ELETION OMISSION DT KNTIPTH KTHMNDU NEPL SITE PLN RHITET: DRWN BY: DTE: MY

More information

Model 1001/1001HPS Drinking Fountain

Model 1001/1001HPS Drinking Fountain INSTLLTION, OPERTION & MINTENNCE INSTRUCTIONS Kleppe Lane Sparks, NV 89-667 (77) 9-72 Fax (77) 9-72 E-mail: haws@hawsco.com website: www.hawsco.com Model 00/00HPS Drinking Fountain No. 20760(9) NOTE TO

More information

R E V I S I O N REV. DRAWN BY ECO No DESCRIPTION DATE APPROVED BILL OF MATERIALS

R E V I S I O N REV. DRAWN BY ECO No DESCRIPTION DATE APPROVED BILL OF MATERIALS NOTES: UNLESS OTHERWISE SPECIFIED. CORNERS DRWN SHRP TO E R.005 MXIMUM. 2. EXTERIOR SURFCE TEXTURE TO E EQUIVLENT TO MT-007. TEXTURE ON ENCLOSURE WILL VRY FROM TIME TO TIME S THE TOOL WERS ND IT ECOMES

More information