1 NEMA 1 ( IP23 ) NEMA 12 ( IP54 )
2 Celebrate Our 100th Anniversary With Us
3 Table of Contents TDL Series NEMA TDE Series NEMA TDA Series NEMA Auxiliary Power TLA Series NEMA Dual Secondary ADL Series NEMA TDG12 Giant Series NEMA TM Series Compact Style TDFM12 Series Slimline Options Description Red on Pilot Light Green on Pilot Light Duplex Receptacle (NEMA 1) Gasketed Duplex Receptacle GFI Receptacle Ground Fault Lights 100K AIC Rating Delete Feature Provides 200K AIC Constant Voltage Lighting Disconnects Suffix R G D C F Z Y X Contact Factory Consult Factory
4 Disconnect Electric Manufacturing Company is pleased to display its new line of Lighting Disconnects. The products in this catalog represent the most advanced series of disconnects available in the market today. Most important, these products have the approvals and certifications needed to compete and ship virtually worldwide. All Disconnects are UL Listed and Canadian UL Listed. UL File E In addition, all series, except Series TDG12, ADL, and ADL12, are CE Marked and Licensed for the European Union T Mark under the EN /30-06 Safety of Machinery Standard. These Disconnects have undergone extensive testing and certification by TÜV Rheinland and Underwriters Labs. With Disconnects, approvals are built in - not a high cost option. Disconnects are manufactured in 11 distinct series with features to meet all your transformer lighting disconnect needs: NEMA 1/IP23 and NEMA 12/IP54/IP65 enclosure styles. Domestic and multitap European voltage combinations. Finger - Safe fuses and transformer terminals. CE Marked, TÜV Bauart Marked, copper wound transformers. European and domestic color coded labels and switches. Custom designs through 15 k and Remote Mount models available. Disconnects comply with automotive specifications. Extensive third party approvals provide great flexibility in design variation. Contact your distributor, your Representative or the factory if the voltage combination, or configuration needed is not shown in this catalog. We would be glad to share our specialty design programs with you to provide disconnects matching the precise specifications required. Note: and weights may vary. Please consult factory for certified drawings. 2 Electric Manufacturing Corporation
5 Lighting Disconnect Series TDL Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 TDL TDL TDL TDL TDL TDL TDL NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Options: Green, ON pilot light available as additional cost option. Other voltage Series TDL A B C D E F Series TDL Outline Drawings Receptacle Supplied on 1 k and Larger Side View
6 Lighting Disconnect Series TDL12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse F4 250 TDL TDL TDL TDL TDL TDL TDL NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDL12 A B C D E F G Series TDL12 Outline Drawings Optional Receptacle Available Bottom View 4 Electric Manufacturing Corporation
7 Lighting Disconnect Series TDE 380 V Fuse F3* Lighting Duplex Primary max amps for other voltages may be obtained by dividing capacity by line voltage. Fuse F4 250 TDE TDE TDE TDE TDE TDE TDE NEMA 1 / IP 23 enclosure. Primary Voltage: 380/400/ 416/440/460/480/575 C. Secondary Voltage: 110/115/120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). Overcurrent protection provided: Primary - Class CC Fuse holders only. Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDE A B C D E F Optional Receptacle Available Series TDE Outline Drawings Side View
8 Lighting Disconnect Series TDE V Fuse F3* Lighting Receptacle Primary max amps for other voltages may be obtained by dividing capacity by line voltage. Fuse F4 250 TDE TDE TDE TDE TDE TDE TDE NEMA 12 / IP 54 enclosure. Primary Voltage: 380/400/ 416/440/460/480/575 C. Secondary Voltage: 110/115/120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). Overcurrent protection provided: Primary - Class CC Fuse holders only. Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as an added cost option on all sizes. Green ìon pilot light provided. Options: Other voltage Series TDE12 A B C D E F G Optional Receptacle Available Series TDE12 Outline Drawings Bottom View 6 Electric Manufacturing Corporation
9 Series TDA Disconnect - Auxiliary Power Fuse F1 & F2 * Lighting Duplex * Lighting amps and. duplex amps must not exceed total secondary max amps when used simultaneously. 500 TDA TDA TDA TDA TDA TDA NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. Both sides of secondary isolated from ground. is copper wound metal screen). Primary overcurrent protection provided: Primary - Class CC Secondary fuse holders only for 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Options: Other voltage Series TDA A B C D E F Series TDA Outline Drawings Side View
10 Disconnect - Auxiliary Power Series TDA12 Fuse F1 & F2 Fuse F3* & F4 Lighting Receptacle 500 TDA TDA TDA TDA TDA TDA NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. Both sides of secondary isolated from ground. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDA12 A B C D E F G Series TDA12 Outline Drawings Optional Receptacle Available Bottom View 8 Electric Manufacturing Corporation
11 Dual Secondary Lighting Disconnect Series TLA Fuse F1 & F2 One Secondary 1 Secondary 2 One One Fuse F3* & F4 Two Two Two Fuse F TLA TLA TLA TLA TLA TLA TLA TLA NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle optional on all sizes. Green ON pilot light optional on all sizes. Other options: Other voltage A B C D E F Series TLA Series TLA Outline Drawings Optional Receptacle Available Side View
12 Dual Secondary Lighting Disconnect Series TLA12 Fuse F1 & F2 One Secondary 1 Secondary 2 One One Fuse F3* & F4 Two Two Two Fuse F TLA TLA TLA TLA TLA TLA TLA TLA NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Green ON pilot light provided. Gasketed receptacle optional on all sizes. Other options: Other voltage A B C D E F G Series TLA12 Series TLA12 Outline Drawings Optional Receptacle Available Bottom View 10 Electric Manufacturing Corporation
13 Lighting Disconnect Series ADL Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 ADL ADL ADL ADL ADL ADL ADL NEMA 1 / IP 23 enclosure Primary Voltage: 480 C Secondary Voltage: 120 C. 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Options: Green or red ON pilot light available as additional cost option. Other voltage Series ADL A B C D E F Series ADL Outline Drawings Receptacle Supplied on 1 k and Larger Side View
14 Lighting Disconnect Series ADL12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse F4 250 ADL ADL ADL ADL ADL ADL ADL NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. One side of secondary grounded. is copper wound metal screen). Complies with automotive industry specifications. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as additional cost option. Green ìon pilot light provided. Options: Other voltage combinations are available. Red ON pilot light available. Series ADL12 A B C D E F G Series ADL12 Outline Drawings Optional Receptacle Available Bottom View 12 Electric Manufacturing Corporation
15 Large Lighting Disconnect Series TDG12 Fuse F1 & F2 Fuse F3* Fuse with Receptacle F3* Fuse with Receptacle F TDG TDG NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. Large capacity and One side of secondary grounded. is copper wound metal screen). Green ON pilot light provided. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (1 1/16 x 2 C\, ). Gasketed duplex receptacle available as additional cost option. Options: Other voltage Custom sizes to 15 k available. Series TDG12 A B C D E F G Optional Receptacle Available Series TDG12 Outline Drawings Bottom View
16 Compact Lighting Disconnects Series TMA, TMB and TMC The Compact Series Lighting Disconnects are designed to minimize backplate footprints to save valuable control panel space. The Compact Series are available in three standard circuits with four sizes for each circuit configuration. Epoxy encapsulated, the Compact Series offers cool operating temperatures, a green ON pilot light, and circuit options that include a duplex receptacle as well as grounded and ungrounded secondaries. Circuit Style Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 TMA-130 A TMA-170 A TMA-190 A TMA-200 A TMB-130 B TMB-170 B TMB-190 B TMB-200 B TMC-130 C TMC-170 C TMC-190 C TMC-200 C Total of lighting amps and duplex amps must not exceed secondary amp rating. Fuse sizes of F3 and F4 are based on the load and maximum secondary amps. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. Compact, panel space-saving design. Choice of three circuit designs. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. Primary overcurrent protection provided: Primary - Class CC Options: Other voltage Complies with automotive industry specifications. Please contact your Representative or our offices for literature on the full line of Disconnects, s and other products. 14 Electric Manufacturing Corporation
17 Circuit Configurations Compact Lighting Disconnects Series TMA Series TMB Series TMC A B C D E F Series TMA Series TMB & TMC
18 OEM Product Groups Series TDFM12 TDFM12 series is a flange mount lighting disconnect in a NEMA 12 enclosure. The enclosure has provisions for side mounting or base mounting. This is used predominantly in automotive plants. Standard voltage is 480 to 120. s from Power-on pilot light All overcurrent protection provided Lockable Allen Bradley 30 amp switch Continuous welded seams Hinged door with gasketing Special voltages available Other options- consult factory RATING CATALOG NUMBER WEIGHT (LBS) 1000 TDFM TDFM TDFM TDFM General Purpose Dry Type Distribution Single Phase, Three Phase, Buck Boost, Motor Drive Isolation, Custom Designs Single Phase, k - Series 35, 80, 85, 61 Three Phase, 3 k k - Series 63, 76 Buck - Boost, 50-5 k - Series 35, 80, 85 Motor Drive Isolation, 3 k k - Series 63 CE Marked Single and Three Phase Units - Series ES-11, Series ES-31 K Factor, 15 k k - Series TK Custom Designs - Core and Coil Designs - Autotransformers - UL and CSA Family Approvals Industrial Control s, Servo Drive Isolation s Century Series , 103, 107, 109 Primary Installed Fuse Available Series 50, Screw Terminals - Domestic Suffix 052, 053, 054, 056, Export Suffix 058, 059 Series HC, Molded Terminals - Suffix -41, -44, -46, -47 Series HC, Molded Terminals w/ Preconnected Fuse Holders - Suffix -4100, CE Marked Units - Series ES-10 - Suffix.326,.366,.376,.386 Servo Drive Isolation Transfomers - Allen Bradley Type Other Manufacturers Available Custom Designs - UL and CSA Family Approvals 16 Electric Manufacturing Corporation
19 Disconnect EU Declaration of Conformity Declaration of Conformity According to EN/IEC Manufacturerís Name: Electric Mfg. Company Manufacturerís Address: 2987 Franklin Street Detroit, Michigan U.S.A. Electric Mfg. Company declares that the product prefixes cited below: Model Numbers: Series TDL Series TDL12 Series TDE Series TDE12 Series TDA Series TDA12 Series TLA Series TLA12 Series DES ( Specialty / Custom Applications ) Conform to the following standards: Supplementary Information: Safety: EN/IEC , JULY, 2006 Safety of Machinery- Electrical Equipment of Machines EN 61558, Isolating s and Safety Isolating Requirements When properly installed and used, the Disconnect Series cited above meet the essential requirements, are in conformity with, and the CE Marking has been applied, according to the relevant EC Directives listed above and appropriate sections of the Low Voltage Directive 73/23/EEC. Licensed by TÜV Rheinland of North America, Inc, license T , dated December 5, Electric Manufacturing Company Dave Shah Chief Engineer Detroit, Michigan USA January, 1998 Approved By: D. Shah Initial Written By: C. Lincoln Initial Revision 1.3 Date 4/1/
20 Electric Manufacturing Company CE Marked Disconnects Disconnects provide off the shelf solutions for lighting and auxilary power to control panels world wide. All disconnects are UL and Canadian UL Listed. In addition, most series have been tested and licensed by TÜV Rheinland as being in compliance with EN and EN These products bear both the CE Mark and the European Union "T Mark under the Safety of Machinery Standard. With Disconnects, approvals are built in - not a high cost option. CE Marked s also supplies single and three phase CE Marked transformers. Series ES s offer a global solution for transformer acceptability and reliability. Series ES are UL and Canadian UL Listed, CE Marked, and have been tested and licensed by TÜV Rheinland as being in compliance with EC Directives and the relevant sections of the Low Voltage Directive. Request Transfax Bulletin 107 for more information.
Transformer Disconnects
Disconnects For Control Panel Lighting and Auxillary Power UL and CUL Listed TÜV Rheinland Licensed CE Marked Series Electric Manufacturing Company Table of Contents TDLK Series NEMA 1-12... 3-4 TDEK Series
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationTransformer Disconnects
Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................
More informationEngineered solutions for power and the environment
C e n t u ry S e r i e s I n d u s t r i a l C o n t r o l T r a n s f o r m e r s Engineered solutions for power and the environment s we celebrate our 100th nniversary, the Dongan Team wishes to thank
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationEngineered solutions for power and the environment
Dongan Electric Mfg. Co General 2018 Your source for standard and custom transformers Engineered solutions for power and the environment Table of Contents Single Phase... 4 General Purpose... 5 Diagrams...
More informationIndustrial Control Power Transformers Class MT
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationIndustrial Control Power Transformers
09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationIndustrial Control Transformers
The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationTransformers 6. Gross Automation (877)
Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationType FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers
Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page
More informationGeneral Purpose Buck - Boost Wiring Diagrams... 86
SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for
More information1329I Integrated Drive/Motor CE Filter Option Kit
Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the
More informationIndustrial Control Transformers
Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationHPS Spartan Industrial Open Core & Coil Control Transformer
HPS Spartan Industrial Open Core & Coil Control Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the
More informationBulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks
Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationDry Type Distribution Transformers
Low Temperature Rise SolaHD low temperature rise transformers feature a 220 C insulation system and temperature rise of only 80 C or 115 C under full nameplate load. Reduction in temperature rise increases
More information2 SLR Series Line Reactors... 50
Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...
More informationThese documents contain additional information concerning related products from Rockwell Automation.
Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 0-Series Drive Installation Instructions PowerFlex 0-Series Programming
More informationPower Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching
Power Supplies AC to DC Power Supply Units AC to 24VDC Regulated Primary Switching Single Phase 100 / 240 VAC 24VDC 5 VDC 12VDC 48VDC 1 Amp TO 20 Amp Three Phase 480 VAC 24VDC 10 Amp to 50 Amp DIN RAIL
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationThree Phase Transformers
Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC
More informationAM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles
AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked
More informationJim Baker President, Electro-Matic Products, Inc.
Electro-Matic Products, Inc., was founded in 1969 with the simple goal to be a leader in the supply of high technology automation components and services. Electro-Matic has grown with its customers, rapidly
More informationBUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:
Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--
More informationCompact Circuit Protector (CCP)
Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description
More informationCompact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm
Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and
More informationTotally Enclosed Non-Ventilated
5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units
More informationCENTERLINE 2100 Motor Control Centers
TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous
More informationTanning Bed Transformers
Tanning Bed Transformers Complete line of transformers designed specifically for the tanning industry. SolarTran Tanning Bed Transformers are specifically designed to serve the voltage transformation needs
More informationM9203-xxx-2(Z) Series Electric Spring-Return Actuators
Code No. LIT-1900682 Issued January 2, 2014 M9203-xxx-2(Z) Series Electric Spring-Return Actuators Description The M9203-xxx-2(Z) Series Electric Spring-Return Actuators provide control of dampers in HVAC
More informationENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS
Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More information9070T150D1 Industrial Control Transformer, 150VA
Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary
More informationCompact Circuit Protector (CCP)
UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationRotary Disconnect Switches, Bulletin 194R
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationPower Supplies. POWER SUPPLIES AC to 24VDC Regulated Primary Switching. TRANSIENT VOLTAGE SUPPRESSORS Industrial Design MINI UNIVERSAL MOUNT
Power Supplies AC to DC AC to 24VDC Regulated Primary Switching SINGLE PHASE 115 / 230 VAC 24VDC 5 VDC 12VDC 10 AMP TO 20 AMP THREE PHASE 480 VAC 24VDC 10 AMP TO 50 AMP! DIN RAIL MOUNT! COMPACT DESIGN
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More informationControl Circuit Transformers
Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit
More informationProducts :: Circuit Protection :: Thermal Circuit Breakers
Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers
More informationCompact Circuit Protector (CCP)
UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the
More informationL-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W
July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
More informationSECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS
SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationM-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS
MAGNITUDE LIGHTING C DIMMABLE DIM DOWN TO 1% CLASS 2 12V DC P/N: M20L12DC-AR Magnitude's M20L12DC-AR is the most compact LED driver on the market with a magnetic transformer core. It is equipped with two
More informationDry Type Distribution Transformers
Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA
More informationCUBEFuse. CUBEFuse catalog numbers (amps)
The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when
More informationCompact Circuit Protector (CCP)
UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the
More informationElectric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT
Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals
More information50 Series. Features. Suffix Suffix Series Voltage Combinations
Features C 50 Combinations Suffix -052 x 24 ll Copper Windings Rugged coil mounted screw terminals UL Class 105 C insulation system, 55 C temperature rise through 750 UL Class 10 C insulation system, C
More informationVA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators
FIG:mntpos_H2O_app VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators Installation Instructions VA9208-BAA-3, VA9208-BAC-3, VA9208-BDA-3 VA9208-BDC-3, VA9208-BGA-3, VA9208-BGC-3 Applications
More informationBulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks
Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method
More informationDry Type Distribution Transformers
Dry Type Distribution Transformers 5 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 through 500. Indoor and outdoor models available.
More informationPH250MQMJ CNTL 250VA 240X X240
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product
More informationM9203-xxx-2(Z) Series Electric Spring Return Actuators
M9203-AGx-2(Z), M9203-GGx-2(Z), M9203-Bxx-2(Z) M9203-xxx-2(Z) Series Electric Spring Return Actuators Code No. LIT-1900682 Issued February 16, 2011 Description The M9203-xxx-2(Z) Series Electric Spring
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches
More informationDry Type Distribution Transformers
Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for hazardous locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating
More informationRef No: N Date: December 7, Fuseholder Assemblies No. 2. Call us today! See Attachment 1 for Effective Dates.
Ref No: N07-094 Date: December 7, 2007 Fuseholder Assemblies No. 2 See Attachment 1 for Effective Dates. Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272
More informationACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX
763.422.26 SPEC-177 B763.422.2211 DISCONNECT SEQUESTR PREFERRED-CUTOUT DISCONNECTS SEQUESTR EXTERNAL DISCONNECTS SEQUESTR PrefERREd-CutoUT DisconnECTS SEQUESTR ExTERnal Disconnects STAINLESS STEEL SEQUESTR
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationHubbell Marine Isolation Transformers 15 kva and 25 kva Models
Shore Power System 15 kva and 25 kva Models Protects Sensitive Equipment on Board Virtually Eliminates Potential for In-Water Stray Current Can be wired per ABYC E-11 for either a Polarization or Isolation
More informationEffective December 2015 Supersedes September 2013
Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationSECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS
SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationFeatures, Benefits and Functions
-8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor
More informationUse the following standards for system design and performance requirements.
Design The Electrical Motor Design Guidelines contains design criteria and specifications used in the procurement of electrical 3-phase AC induction motors. Table of Contents 1. Introduction 2. Design
More informationMIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6
I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationAPEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS
APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS Product Type: APEX10, APEX20 and APEX40 Servo Drives The above products are in compliance with the requirements of directives 72/23/EEC Low
More informationCPT Series Control Transformers
CPT Series Control s 50 VA to 500 VA 480 VAC Primary 120 VAC Secondary (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationIndustrial Control Transformers
Industrial Control Transformers 5 The SBE - Encapsulated Series The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationMachine Tool Industrial Control Transformers
Hammond Power Solutions Inc. Page of Machine Tool Industrial Control Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high
More informationBUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses
Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information
More information4.1. Definite Purpose Contactors and Starters. Contents
. Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,
More informationCompact Circuit Protector (CCP)
Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....
More informationGeneral Information. General Information H-1. Safety Standards H-2 H-12 ISO 9001, ISO H-13 H-14. Voltages H-15. Overview H-16.
H-2 in s H-12 in s H General Information H-13 Oriental Motor Corporate Overview Oriental Motor Global Sales Network H-14 H-15 H-16 Oriental Motor Corporate Overview Oriental Motor Global Sales Network
More informationQuik-Spec Electrical Gear
Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................
More informationDECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency