Transformer Disconnects

Size: px
Start display at page:

Download "Transformer Disconnects"

Transcription

1 Disconnects For Control Panel Lighting and Auxillary Power UL and CUL Listed TÜV Rheinland Licensed CE Marked Series

2 Electric Manufacturing Company

3 Table of Contents TDLK Series NEMA TDEK Series NEMA TDAK Series NEMA Auxiliary Power TLAK Series NEMA Dual Secondary ADLK Series NEMA TDGK12 Giant Series NEMA TM Series Compact Style TDFM12 Series Slimline Description Red on Pilot Light Green on Pilot Light Duplex Receptacle (NEMA 1) Gasketed Duplex Receptacle GFI Receptacle Ground Fault Lights Delete Feature Provides Suffix R G D C F Z X

4 Disconnect Electric Manufacturing Company is pleased to display its new line of Lighting Disconnects. The products in this catalog represent the most advanced series of disconnects available in the market today. Most important, these products have the approvals and certifications needed to compete and ship virtually worldwide. All Disconnects are UL Listed and Canadian UL Listed. UL File E In addition, all series, except Series TDG12, ADLK, and ADLK12, are CE Marked and Licensed for the European Union T Mark under the EN /30-06 Safety of Machinery Standard. These Disconnects have undergone extensive testing and certification by TÜV Rheinland and Underwriters Labs. With Disconnects, approvals are built in - not a high cost option. Disconnects are manufactured in 11 distinct series with features to meet all your transformer lighting disconnect needs: NEMA 1/IP23 and NEMA 12/IP54/IP65 enclosure styles. Domestic and multitap European voltage combinations. Finger - Safe fuses and transformer terminals. CE Marked, TÜV Bauart Marked, copper wound transformers. European and domestic color coded labels and switches. Disconnects comply with automotive specifications. Extensive third party approvals provide great flexibility in design variation. Contact your distributor, your Representative or the factory if the voltage combination, or configuration needed is not shown in this catalog. We would be glad to share our specialty design programs with you to provide disconnects matching the precise specifications required. NOTE: and weights may vary.please consult factory for certified drawings. 2 Electric Manufacturing Company

5 Lighting Disconnect Series TDLK Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse 250 TDLK TDLK TDLK TDLK TDLK TDLK TDLK Approx. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Dedicated physical earth terminal. Options: Green, ON pilot light available as additional cost option. Other voltage combinations available. EN Series TDLK A B C D E F Series TDLK Outline Drawings S2 S1 1K & GREATER Receptacle Supplied on 1 k and Larger *F3 fuse size will vary if Side View

6 Lighting Disconnect Series TDLK 12 Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse Approx. 250 TDLK TDLK TDLK TDLK TDLK TDLK TDLK NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN Series TDLK 12 A B C D E F G Series TDLK 12 Outline Drawings S2 S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View 4 Electric Manufacturing Company

7 Lighting Disconnect Series TDEK 380 V* NEMA 3R/IP23 Enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Fuse F3* Lighting Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. Duplex F1 H1 Fuse EN Approx. 250 TDEK TDEK TDEK TDEK TDEK TDEK TDEK * Primary max amps for other voltages may be obtained by dividing by line voltage Series TDEK (380,400) (416,440) (575) A B C D E F Series TDEK Outline Drawings S2 S1 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available *F3 fuse size will vary if Side View

8 Lighting Disconnect Series TDEK V* Fuse F3* Lighting Receptacle Fuse Approx. 250 TDEK TDEK TDEK TDEK TDEK TDEK TDEK * Primary max amps for other voltages may be obtained by dividing by line voltage NEMA 12/IP65 Enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED Complies with automotive Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). Primary overcurrent protection provided: Secondary fuse holders only for Series TDEK 12 Outline Drawings 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. A B C D E F G F1 H1 EN Series TDEK 12 (380,400) (416,440) (575) S2 S1 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available *F3 fuse size will vary if Side View 6 Electric Manufacturing Company

9 Disconnect - Auxiliary Power Series TDAK Fuse F1 & F2 * Lighting Duplex Approx. 500 TDAK TDAK TDAK TDAK TDAK TDAK * Lighting amps and. duplex amps must not exceed total secondary max amps when used simultaneously. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED. Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). Primary overcurrent protection provided: Secondary fuse holders only for 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN Series TDAK A B C D E F Series TDAK Outline Drawings Side View

10 Disconnect - Auxiliary Power Series TDAK 12 Fuse F1 & F2 Fuse F3* & Lighting Receptacle Approx. 500 TDAK TDAK TDAK TDAK TDAK TDAK NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED. Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN Series TDAK 12 A B C D E F G Series TDAK 12 Outline Drawings Optional OPTIONAL Receptacle DUPLEX Available Side View *F3 fuse size will vary if 8 Electric Manufacturing Company

11 Series TLAK Dual Secondary - Lighting Disconnect Fuse F1 & F2 One Secondary 1 Secondary 2 Approx. One One Fuse F3* & Two Two Two Fuse F TLAK TLAK TLAK TLAK TLAK TLAK TLAK TLAK NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. 200K AIC RATED. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound with electrostatic shield (earth metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle optional on all sizes. Green ON pilot light optional on all sizes. A B C D E F Dedicated physical earth terminal. Other options: Other voltage combinations available. EN Series TLAK L1 L2 Series TLAK Outline Drawings PE S4 S3 OPTIONAL DUPLEX Optional Receptacle Available Side View *F3 fuse size will vary if

12 Dual Secondary - Lighting Disconnect Series TLAK 12 Fuse F1 & F2 One Secondary 1 Secondary 2 Approx. One One Fuse F3* & Two Two Two Fuse F TLAK TLAK TLAK TLAK TLAK TLAK TLAK TLAK NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. 200K AIC RATED. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound with electrostatic shield (earth metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Green ON pilot light provided. Gasketed receptacle optional on all sizes. A B C D E F G Dedicated physical earth terminal. Other options: Other voltage combinations available. EN Series TLAK 12 L1 L2 Series TLAK 12 Outline Drawings PE X1 F3 F S4 S3 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available Bottom View *F3 fuse size will vary if 10 Electric Manufacturing Company

13 Lighting Disconnect Series ADLK Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse 250 ADLK ADLK ADLK ADLK ADLK ADLK ADLK Approx. NEMA 1 / IP 23 enclosure Primary Voltage: 480 C Secondary Voltage: 120 C. 60 Hz 200K AIC RATED. One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Dedicated physical earth terminal. Options: Green or red ON pilot light available as additional cost option. Other voltage combinations available. Series ADLK X2 A B C D E F Series ADLK Outline Drawings S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View

14 Lighting Disconnect Series ADLK 12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse 250 ADLK ADLK ADLK ADLK ADLK ADLK ADLK Approx. NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). Complies with automotive industry specifications. All overcurrent protection provided Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as additional cost option. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations are available. Red ON pilot light available. Series ADLK 12 X2 A B C D E F G Series ADLK 12 Outline Drawings S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View 12 Electric Manufacturing Company

15 Large Lighting Disconnect Series TDGK 12 Fuse F1 & F2 Fuse F3* Fuse with Receptacle F3* Fuse with Receptacle Approx TDGK TDGK NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. Large capacity and One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. All overcurrent protection provided: Secondary - Supplementary fuses (1 1/16 x 2 i# ). Gasketed duplex receptacle available as additional cost option. Dedicated physical earth terminal. Options: Other voltage combinations available. Series TDGK 12 A B C D E F G Series TDGK 12 Outline Drawings OPTIONAL DUPLEX Optional Receptacle Available *F3 fuse size will vary if Bottom View

16 Compact - Lighting Disconnects Series TMAK, TMBK and TMCK The Compact Series Lighting Disconnects are designed to minimize backplate footprints to save valuable control panel space. The Compact Series are available in three standard circuits with four sizes for each circuit configuration. Epoxy encapsulated, the Compact Series offers cool operating temperatures, a green ON pilot light, and circuit options that include a duplex receptacle as well as grounded and ungrounded secondaries. Circuit Style Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse Approx. 250 TMAK-130 A TMAK-170 A TMAK-190 A TMAK-200 A TMBK-130 B TMBK-170 B TMBK-190 B TMBK-200 B TMCK-130 C TMCK-170 C TMCK-190 C TMCK-200 C Total of lighting amps and duplex amps must not exceed secondary amp rating. Fuse sizes of F3 and are based on the load and maximum secondary amps. * F3 fuse size will vary if NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. Compact, panel space-saving design. Choice of three circuit designs. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. Primary overcurrent protection provided: Dedicated physical earth terminal. Options: Other voltage combinations available. Complies with automotive industry specifications. TOAK, TOBK & TOCK open style available. Please contact your Representative or our offices for literature on the full line of Disconnects, s and other products. 14 Electric Manufacturing Company

17 Compact - Lighting Disconnects Circuit Configurations Series TMAK Series TMBK Series TMCK G G G A B C D E F Series TMAK Series TMBK & TMCK

18 OEM Product Groups Series TDFM12 TDFM12 series is a flange mount lighting disconnect in a NEMA 12 enclosure. The enclosure has provisions for side mounting or base mounting. This is used predominantly in automotive plants. Standard voltage is 480 to 120. s from Power-on pilot light All overcurrent protection provided Lockable Allen Bradley 30 amp switch Continuous welded seams Hinged door with gasketing Special voltages available Other options- consult factory RATING CATALOG NUMBER WEIGHT (LBS) 1000 TDFM TDFM TDFM TDFM General Purpose Dry Type Distribution Single Phase, Three Phase, Buck Boost, Motor Drive Isolation, Custom Designs Single Phase, k - Series 35, 80, 85, 61, 41 Three Phase, 3 k k - Series 63, 73, 76, 83 Buck - Boost, 50-5 k - Series 35, 80, 85 Motor Drive Isolation, 3 k k - Series 63 CE Marked Single and Three Phase Units - Series ES-11, Series ES-31 K Factor, 15 k k - Series TK Custom Designs - Core and Coil Designs - Autotransformers - UL and CSA Family Approvals Industrial Control s, Servo Drive Isolation s Century Series , 103, 107, 109 Primary Installed Fuse Available Series 50, Screw Terminals - Domestic Suffix 052, 053, 054, 056, Export Suffix 058, 059 Series HC, Molded Terminals - Suffix -41, -44, -46, -47 CE Marked Units - Series ES-10 - Suffix.326,.366,.376, Electric Manufacturing Company

19

20 C.. s and Custom Magnetics Factory and Local Warehouse Stocks for: Industrial Control s General Purpose s Single Phase Three Phase Motor Drive Isolation s Control s K - Factor s High Voltage Ignition Gas Ignition Oil Ignition Solid State Lighting Disconnects Signaling Hospital Isolation Epoxy Encapsulated CE Marked s Auto s High Voltage s Solar and Wind Energy s DOE Energy Efficient s Custom Designs Available: Domestic & Export Voltages Custom Colors Special Frequencies Custom Enclosures Match Current or Custom Core & Coil Units CE Marked s Chokes Reactors Comprehensive Family Approvals for Electric Manufacturing Company 2987 Franklin Street Detroit, MI USA la s s I Bauart gepruft.. TUV Rheinland latin g E N Is o Fax: sales@dongan.com Pioneer Company A Wholly Owned Subsidiary 500 Cedar Street Pioneer, OH USA LD Engineered Solutions Since 1909

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Celebrate Our 100th Anniversary With Us Table of Contents TDL Series NEMA 1-12... 3-4 TDE Series NEMA 1-12.... 5-6 TDA Series NEMA 1-12.... 7-8 Auxiliary Power TLA Series

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Transformers 6. Gross Automation (877)

Transformers 6. Gross Automation (877) Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

Engineered solutions for power and the environment

Engineered solutions for power and the environment Dongan Electric Mfg. Co General 2018 Your source for standard and custom transformers Engineered solutions for power and the environment Table of Contents Single Phase... 4 General Purpose... 5 Diagrams...

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Engineered solutions for power and the environment

Engineered solutions for power and the environment C e n t u ry S e r i e s I n d u s t r i a l C o n t r o l T r a n s f o r m e r s Engineered solutions for power and the environment s we celebrate our 100th nniversary, the Dongan Team wishes to thank

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Tanning Bed Transformers

Tanning Bed Transformers Tanning Bed Transformers Complete line of transformers designed specifically for the tanning industry. SolarTran Tanning Bed Transformers are specifically designed to serve the voltage transformation needs

More information

Industrial Control Transformers

Industrial Control Transformers The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

HPS Spartan Industrial Open Core & Coil Control Transformer

HPS Spartan Industrial Open Core & Coil Control Transformer HPS Spartan Industrial Open Core & Coil Control Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the

More information

Totally Enclosed Non-Ventilated

Totally Enclosed Non-Ventilated 5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units

More information

Jim Baker President, Electro-Matic Products, Inc.

Jim Baker President, Electro-Matic Products, Inc. Electro-Matic Products, Inc., was founded in 1969 with the simple goal to be a leader in the supply of high technology automation components and services. Electro-Matic has grown with its customers, rapidly

More information

Midwest Dry Type Transformers

Midwest Dry Type Transformers Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Three Phase Transformers

Three Phase Transformers Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series

More information

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS MAGNITUDE LIGHTING C DIMMABLE DIM DOWN TO 1% CLASS 2 12V DC P/N: M20L12DC-AR Magnitude's M20L12DC-AR is the most compact LED driver on the market with a magnetic transformer core. It is equipped with two

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

These documents contain additional information concerning related products from Rockwell Automation.

These documents contain additional information concerning related products from Rockwell Automation. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 0-Series Drive Installation Instructions PowerFlex 0-Series Programming

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

Non-Ventilated Automation Transformers 6

Non-Ventilated Automation Transformers 6 Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

PH250MQMJ CNTL 250VA 240X X240

PH250MQMJ CNTL 250VA 240X X240 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Transformers 5 The SBE - Encapsulated Series The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

SECTION VARIABLE FREQUENCY DRIVE UNITS

SECTION VARIABLE FREQUENCY DRIVE UNITS SECTION 26 29 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide variable frequency drive (VFD) units, complete and operable, in accordance with the Contract Documents. It

More information

Machine Tool Industrial Control Transformers

Machine Tool Industrial Control Transformers Hammond Power Solutions Inc. Page of Machine Tool Industrial Control Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models Shore Power System 15 kva and 25 kva Models Protects Sensitive Equipment on Board Virtually Eliminates Potential for In-Water Stray Current Can be wired per ABYC E-11 for either a Polarization or Isolation

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

50 Series. Features. Suffix Suffix Series Voltage Combinations

50 Series. Features. Suffix Suffix Series Voltage Combinations Features C 50 Combinations Suffix -052 x 24 ll Copper Windings Rugged coil mounted screw terminals UL Class 105 C insulation system, 55 C temperature rise through 750 UL Class 10 C insulation system, C

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Low Temperature Rise SolaHD low temperature rise transformers feature a 220 C insulation system and temperature rise of only 80 C or 115 C under full nameplate load. Reduction in temperature rise increases

More information

Efficiency is in our DNA

Efficiency is in our DNA Efficiency is in our DNA EFFICIENCY IS IN OUR DNA EFFICIENCY AND ENERGY-SAVINGS IS PART OF OUR CULTURE From the day the company was founded in 1942, Marcus Transformer has focused its technology on providing

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Control Circuit Transformers

Control Circuit Transformers Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control

More information

ACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX

ACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX 763.422.26 SPEC-177 B763.422.2211 DISCONNECT SEQUESTR PREFERRED-CUTOUT DISCONNECTS SEQUESTR EXTERNAL DISCONNECTS SEQUESTR PrefERREd-CutoUT DisconnECTS SEQUESTR ExTERnal Disconnects STAINLESS STEEL SEQUESTR

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Miscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control

Miscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control Table of Contents Section General Purpose Dry Type 600 Volts and Below General Purpose Transformer, see page -2 Sealed Transformer, see page -10 90701050D2 Industrial Control Transformer, see page - EE

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

LED Auxiliary Devices

LED Auxiliary Devices LED Auxiliary Devices 30 YEARS OF EXCELLENCE 1985-2015 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Three-phase isolating transformers for photovoltaic and wind-power systems

Three-phase isolating transformers for photovoltaic and wind-power systems BTTTFV SERIES VERY LOW LOSSES THREE PHASE "GREEN ENERGY" TRANSFORMERS DRY TYPE THREE PHASES TRANSFORMERS Rated frequency: 50/60Hz Rated primary voltage: 400V Rated secondary voltage: 400V Group: YNyn0

More information

Use the following standards for system design and performance requirements.

Use the following standards for system design and performance requirements. Design The Electrical Motor Design Guidelines contains design criteria and specifications used in the procurement of electrical 3-phase AC induction motors. Table of Contents 1. Introduction 2. Design

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Low Voltage Lighting Power Supplies

Low Voltage Lighting Power Supplies SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage

More information

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. Advantages of the 72 Alternating Relay The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. The Model 72 series Alternating Relay is designed for duplex pumping systems where

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Dry Type Distribution Transformers 5 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 through 500. Indoor and outdoor models available.

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

CPT Series Control Transformers

CPT Series Control Transformers CPT Series Control s 50 VA to 500 VA 480 VAC Primary 120 VAC Secondary (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets 1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets MODEL NUMBER: EMS1250UL Highlights 12V DC or 120VAC input; 120V AC output; 2 NEMA 5-15R hospital-grade outlets 1250

More information

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ File E132594 Project 02ME17432 2003-02-09 REPORT on CORD CONNECTED CLASS 2 POWER UNITS Globtek Inc. Northvale, NJ Copyright 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances COMPANY PROFILE Company Overview Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances GEOGRAPHIC SCOPE QUALITY GUARANTEED Trasfeco produces

More information

Products :: Circuit Protection :: Thermal Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

Preferred Cutout, Disconnect Enclosure, Type 12

Preferred Cutout, Disconnect Enclosure, Type 12 763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com

More information

9070T150D1 Industrial Control Transformer, 150VA

9070T150D1 Industrial Control Transformer, 150VA Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information