Tankless Inc. Product Catalog 6/26/2018. Commercial & Industrial 3-Phase Water Heaters. Commercial & Industrial 3-Phase Water Heating COMPANY
|
|
- Cory McGee
- 5 years ago
- Views:
Transcription
1 Product Catalog 6/26/2018 Commercial & Industrial 3-Phase Water Heaters
2 Feature Comparison comparison of features in our model lines, and against the competition. Features for competing products are based on readily available public information. Recommended applications CF Series Mechanical Where ruggedness is required, but precise temperature is not. CE Series Electronic Where precise temp. and adjustability are required CES Series Safety applications Tepid water for emergency stations per OSH CERO Series Caustic liquids Caustic fluids including reverse osmosis water Competition Keltech Size Range kw kw kw kw kw kw kw Size Range BTU/hr KBTU/hr KBTU/hr KBTU/hr KBTU/hr KBTU/ hr Voltages 3-phase 208, 240, 480 Delta or Wye, 575 V Dynamic Load Balancing for even element wear 3-phase 208, 240, 480 Delta or Wye, 575 V 3-phase 208, 240, 480 Delta or Wye, 575 V 3-phase 208, 240, 480 V Delta or Wye Various 208, 240, 480, 575, 600 V No Yes Yes Yes Yes No Heat exchanger 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel Copper & Brass Plastic Pipe size ¾ 1¼ ¾ 1¼ ¾ 1¼ ¾ 1¼ ¾ 1¼ ½ 1¼ Element sheathing 840 Incoloy 840 Incoloy 840 Incoloy Titanium 840 Incoloy None Temperature range F / C F / C F / C F / C F / C Temperature adjustability Is output temperature measured and displayed? None by 1 F by 1 F by 1 F Yes Yes No Yes ctual and requested output temperatures shown if unit is over capacity Yes ctual and requested output temperatures shown if unit is over capacity Yes ctual and requested output temperatures shown if unit is over capacity Yes Eemax Various KBTU/hr 208, 240, 480, 575, 600 V 1- & 3-phase F / C Yes NEM3 No NEM 4 ctivation flow rate 0 gpm (constant hot) 0.5, 2.0 gpm 0.5, 2.0 gpm 0.5, 2.0 gpm 1.5 gpm 0.7, 1.0, 2.5 gpm Freeze protection Standard Standard Standard Standard Standard Optional Flow rate (@ 40 psi) Pressure drop (@ 40 psi) Elements individually fused 50 gpm gpm, 4 12 psi, 2 12 psi, gpm, 2 12 psi, gpm, 2 12 psi, gpm 8 40 gpm, dependent on pipe size 4 x psi, dependent on pipe size Yes Yes Yes Yes Yes Yes Standard enclosure NEM 3 NEM 3 NEM 3 NEM 3 NEM 3 NEM 3 Optional enclosures NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x Over-temperature protections Warranty Unknown 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 1-year electrical 20+ psi 8-year heat exchanger 2-year electrical Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26, 2018
3 Options Description pplicable Models NEM 4 Enclosure air-tight and water-tight For three- or six-element heater including all drains and fittings surrounding the plumbing. Powder-coated white. Includes watertight window to view the control boards in the electronic models. 24 x 20 x 10 CF 12, 15, 18, 24, 27, 36 CE 12, 15, 18, 24, 27, 36 CES 12, 15, 18, 24, 27, 36 CERO 12, 15, 18, 24, 27, 36 For twelve-, eighteen- or twenty-four-element heater including all drains and fittings surrounding the plumbing. Powder-coated white. Includes water-tight window to view the control boards for the electronic units. CF 81, 90, 108 CE 108, 120, 144 CES all CERO all 48 x 24 x 12 NEM 4X Enclosure air-tight and water-tight stainless steel For three- or six-element heater including all drains and fittings surrounding the plumbing. Includes water-tight window to view the control boards in the electronic models. 24 x 20 x 10 CF 12, 15, 18, 24, 27, 36 CE 12, 15, 18, 24, 27, 36 CES 12, 15, 18, 24, 27, 36 CERO 12, 15, 18, 24, 27, 36 For twenty four element heater including all drains and fittings surrounding the plumbing. Includes water-tight window to view the control boards in the electronic models. 48 x 24 x 12 CF 48, 54, 72, 81, 90, 108 CE 48, 54, 72, 108, 120, 144 CES 48, 54, 72 CERO 48, 54, 72 Thermostats CF Series single-temperature thermostats regulate when the unit heats plus provide over-temperature protection. Select an activation temperature of 90, 110, 125, 145, 155, 185, or 200 F, or close to the CF all Temperature setting must be selected when ordering output temperature of the heater at purchase. External Kill Switch Mounted to the outside door of a NEM 4 or 4x enclosure and allows the customer to kill power inside the unit by depressing the Requires NEM 4 or 4X enclosure red button. Mixing Valve vailable for varying output temperatures in ¾ 1¼ sizes ll series and models 2060 Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26,
4 CF Series General Purpose Water Heaters CF Series models are a low technology, reliable way to heat water. They are electromechanical and heat water based on the temperature measured by a thermostat as the water/fluid passes the element. CF Series models are accurate to ±7 degrees F at low flow rates. They are more accurate at higher flow rates, and larger CF models are more accurate than smaller models. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements ctivates on demand but stays hot without flow ensuring immediate hot water on demand Output temperature range Fahrenheit Individually fused elements Output temperature is fixed and based on the thermostat installed Unique water flow relieves air build-up resulting in increased longevity Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Conforms to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. Options NEM 4 and 4x enclosures are available Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26, 2018
5 CF Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Enclosure Size Includes Fittings (W x H x D) CF 12 KW CF 12 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F x 23 x 9 CF 12 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 15 KW CF 15 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 15 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 18 KW CF 18 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F ¾ x 23 x Delta available at added cost CF 18 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 24 KW CF 24 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 24 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 27 KW CF 27 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 27 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 48 KW CF 48 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 48 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 54 KW CF 54 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 54 KW CF 54 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 81 KW CF 81 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 90 KW CF 90 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 108 KW CF 108 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 108 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 120 KW CF 120 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 CF 144 KW CF 144 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 CF 144 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CF 12 KW 208, 240, 480 Wye CF 15 KW 208, 240, 480 Wye CF 18 KW 208, 240, 480 Wye or Delta CF 24 KW 208, 240, 480 Delta CF 27 KW 208, 240, 480 Delta CF 36 KW 208, 240, 480 Delta, CF 48 KW 208, 240, 480 Delta CF 54 KW 208, 240, 480 Delta CF 72 KW 208, 240, 480 Delta, CF 81 KW 208, 240, 480 Delta CF 90 KW 208, 240, 480 Delta CF 108 KW 208, 240, 480 Delta, CF 120 KW 208, 240, 480 Delta CF 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26,
6 CE Series General Purpose Electronically-Controlled Water Heaters CE Series electronically-controlled water heaters calculate the amount of energy needed to meet hot water demand by measuring flow rate, then activating the minimum number of elements necessary to satisfy that demand. No energy is used when the unit is idle other than the pilot light. Larger CE Series models are normally used as boiler replacements or very specific process manufacturing applications. Smaller CE Series models are used for hand washing or smaller process applications. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements kw models activate on demand at 0.50 GPM kw models activate on demand at 2.0 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Four over-temperature protections Dynamic load balancing ensures even element wear Unique water flow relieves air build-up resulting on increased longevity Freeze protection is a standard feature Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Conforms to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. Options NEM 4 and 4x enclosures are available Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26, 2018
7 CE Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Inches Enclosure Size Includes Fittings (W x H x D) CE 12 KW CE 12 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CE 12 KW ¾ 22.5 x 23 x 7.5 CE 15 KW CE 15 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CE 15 KW ¾ 22.5 x 23 x 7.5 CE 18 KW CE 18 KW 480 Y 480 Wye ¾ 22.5 x 23 x Delta available at added cost CE 18 KW ¾ 22.5 x 23 x 7.5 CE 24 KW CE 24 KW ¾ 22.5 x 32.5 x 7.5 CE 24 KW ¾ 22.5 x 32.5 x 7.5 CE 27 KW CE 27 KW ¾ 22.5 x 32.5 x 7.5 CE 27 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 48 KW CE 48 KW ¾ or X 44 X 8 CE 48 KW ¾ or X 44 X 8 CE 54 KW CE 54 KW ¾ or X 44 X 8 CE 54 KW ¾ or X 44 X 8 CE 60 KW CE 60 KW ¾ or X 44 X 8 CE 60 KW ¾ or X 44 X 8 CE 72 KW CE 72 KW ¾ or X 44 X 8 CE 72 KW ¾ or X 44 X 8 CE 72 KW ¾ or X 44 X 8 CE 108 KW CE 108 KW ¼ 50 X 36 X 12 CE 120 KW CE 120 KW ¼ 50 X 36 X 12 CE 144 KW CE 144 KW ¼ 50 X 36 X 12 CE 144 KW ¼ 50 X 36 X 12 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CE 12 KW 208, 240, 480 Wye CE 15 KW 208, 240, 480 Wye CE 18 KW 208, 240, 480 Wye or Delta CE 24 KW 208, 240, 480 Delta CE 27 KW 208, 240, 480 Delta CE 36 KW 208, 240, 480 Delta, CE 48 KW 208, 240, 480 Delta CE 54 KW 208, 240, 480 Delta CE 60 KW 208, 240, 480 Delta CE 72 KW 208, 240, 480 Delta, CE 108 KW 208, 240, 480 Delta CE 120 KW 208, 240, 480 Delta CE 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26,
8 CES Series Eyewash & Emergency Shower Water Heaters The CES Series is designed to heat water for emergency eyewash stations and emergency drench showers to meet OSH requirements. CES 12 kw through CES 36 kw units should be used solely for eyewash station applications. Depending on size, they will heat up to 7 gallons per minute by 35 F (20 C) and limit the output temperature to OSH requirements. CES 48 kw through CES 144 kw units will meet OSH requirements for many installations including emergency showers. You must test your incoming water temperature on a cold day to verify the size unit you need to comply with requirements. Only the largest units will be sufficient for temperate climates. Customers should target 85 F for best results and must attain 60 F to meet regulations, which also require at least 20 GPM per minute per shower for 15 minutes to comply, plus the drench station at 3 GPM, plus the eyewash station requirements. Features Meets all OSH and NSI Z requirements NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements kw models activate on demand at 0.50 GPM kw models activate on demand at 2.0 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Four over-temperature protections Dynamic load balancing ensures even element wear Freeze protection is a standard feature Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit tested for 1 hour at full load amp draw Conforms to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. Options NEM 4 and 4x enclosures are available Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26, 2018
9 CES Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Inches Enclosure Size Includes Fittings (W x H x D) CES 12 KW CES 12 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CES 12 KW ¾ 22.5 x 23 x 7.5 CES 15 KW CES 15 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CES 15 KW ¾ 22.5 x 23 x 7.5 CES 18 KW CES 18 KW 480 Y 480 Wye ¾ 22.5 x 23 x Delta available at added cost CES 18 KW ¾ 22.5 x 23 x 7.5 CES 24 KW CES 24 KW ¾ 22.5 x 32.5 x 7.5 CES 24 KW ¾ 22.5 x 32.5 x 7.5 CES 27 KW CES 27 KW ¾ 22.5 x 32.5 x 7.5 CES 27 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 48 KW CES 48 KW ¾ or x 44 x 8 CES 48 KW ¾ or x 44 x 8 CES 54 KW CES 54 KW ¾ or x 44 x 8 CES 54 KW ¾ or x 44 x 8 CES 60 KW CES 60 KW ¾ or x 44 x 8 CES 60 KW ¾ or x 44 x 8 CES 72 KW CES 72 KW ¾ or x 44 x 8 CES 72 KW ¾ or x 44 x 8 CES 72 KW ¾ or x 44 x 8 CES 108 KW CES 108 KW ¼ 50 x 36 x 12 CES 120 KW CES 120 KW ¼ 50 x 36 x 12 CES 144 KW CES 144 KW ¼ 50 x 36 x 12 CES 144 KW ¼ 50 x 36 x 12 3-Phase Voltages vailable kw GPM heated by 40 F ssumes 85 F output with 45 F input GPM heated by 35 F ssumes 80 F output with 45 F input GPM heated by 25 F ssumes 70 F output with 45 F input Maximum water flow at 40 PSI ES 12 KW 208, 240 (Single Phase) CES 12 KW 208, 240, 480 Wye CES 15 KW 208, 240, 480 Wye CES 18 KW 208, 240, 480 Wye or Delta CES 24 KW 208, 240, 480 Delta CES 27 KW 208, 240, 480 Delta CES 36 KW 208, 240, 480 Delta, CES 48 KW 208, 240, 480 Delta CES 54 KW 208, 240, 480 Delta CES 60 KW 208, 240, 480 Delta CES 72 KW 208, 240, 480 Delta, CES 108 KW 208, 240, 480 Delta CES 120 KW 208, 240, 480 Delta CES 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26,
10 CERO Series Caustic Fluid Heaters CERO Series models have titanium sheathed elements that will last longer in a caustic environment than standard Incoloy sheathed elements. CERO Series are electronically-controlled water heaters that calculate the amount of energy needed to meet hot water demand, then activating the minimum number of elements necessary to satisfy that demand. No energy is used when the unit is idle other than the pilot light. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers Titanium sheathing for the elements kw models activate on demand at 0.50 GPM kw models ctivate on demand at 2.0 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Options NEM 4 and 4x enclosures are available Conforms Tested to to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. mp Draw Dimensions Output Fittings Standard 208 V 240 V 480 V 575 V Max. Width Height Depth Shipping Shipping BTU/hr Enclosure Operating Pressure Weight Mode CERO 18 kw 61,416 ¾ NEM UPS Custom Carton CERO 27 kw 92,124 ¾ NEM UPS Custom Carton CERO 36 kw 122,832 ¾ NEM UPS Custom Carton Mounting Wall Brackets Wall Brackets Wall Brackets CERO 54 kw 182,248 ¾ or 1 NEM Skid Wall Brackets CERO 72 kw 245,664 ¾ or 1 NEM Skid Wall Brackets 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CERO 18 KW 240, 480 Wye CERO 27 KW 240, 480 Delta CERO 36 KW 240, 480 Delta CERO 54 KW 240, 480 Delta CERO 72 KW 240, 480 Delta Whitfield Park ve Sarasota Fl tankless fax tanklessinc@stiebel-eltron-usa.com June 26, 2018
11 Engineering Specifications 2060 Whitfield Park ve Sarasota Fl tankless fax June 26, Power Inlet/Outlet Heat Number Element Recommended Breakers and Full Load mp Draw 1 Output Size Weight Enclosure Dimensions Output of Size 208 V 240 V of Model inches pounds width height depth btu/hr Elements watts breaker amp breaker amp breaker amp breaker amp draw draw draw draw 12 kw ¾ , kw ¾ , kw ¾ , kw ¾ , kw ¾ , kw ¾ kw ¾ or , kw ¾ or , kw ¾ or , kw ¾ or , kw 1 or 1¼ ¼ 225 9¼ 276, or 24 or 48 or kw 1 or 1¼ ¼ 22¼ 9¼ 307, or 24 or 48 or kw 1 or 1¼ ¼ 22¼ 9¼ 368, or 350 or 24 or 48 or 12 or kw 2 1¼ , kw 2 1¼ , ssumes individually fused elements. Units made after 1/1/15 have individual fused elements. Units made prior to 1/1/15 have the maximum breaker size shown on the front cover label. Check local code for breaker size in your area kw & 144 kw models can be ordered in a 36x36x12 NEM 3 enclosure. Flow Rate vs Temp. Rise Power Flow Rate Temperature Rise degrees Fahrenheit Output gallons/hr. of Model gallons/min kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph ssumes 1¼ pipe size ll water heaters can be plumbed individually or in manifold to create larger systems.
12 2060 Whitfield Park ve Sarasota Fl tankless fax Due to our continuous process of engineering and technological advancement, specifications may change without notice.
Tankless, Inc. Product Catalog 3/29/2018. Commercial & Industrial 3-Phase Water Heaters COMPANY
Product Catalog 3/29/2018 Commercial & Industrial 3-Phase Water Heaters Feature Comparison comparison of features in our model lines, and against the competition. Features for competing products are based
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationUniversal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications
Ruud Commercial Gas Universal Water Heaters Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications Features & Benefits The tighter the commercial
More informationTamas Hydronic Panels BTU Snow Melt Submittal Technical Data
Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas
More informationHARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL
Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL INSTALLATION AND OPERATION MANUAL HUR 8X170FL HUR 5X170FL HUR 3X170FL HUR 1X170FL Harmsco Filtration Products With Patented Up-Flow and Tangential/Rotational
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More informationTamas Hydronic Panels BTU Snow Melt Submittal Technical Data
Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationCIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction
SPECIFICATIONS 6 to 480 kw and higher CIRCULATION HEATERS CH & CHP SERIES Flanged construction 208 volt through 575 volt, 3 phase 5 to 40 watts/in 2 and higher NEMA 4/12 Terminal housing DESCRIPTION Type
More informationSHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET
SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.
More informationWATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential
WATTS/Taras Water Treatment Valves and Accessories Residential Commercial Taras Valve Company, a division of Watts Industries, has been manufacturing quality by-pass valves and accessories for the Water
More informationSeries T2000 Wall Mounted Emergency Eye & Eye/Face Wash
Series T2000 Wall Mounted Emergency Eye & Eye/Face Wash In order to comply with the NSI Z358.1 Standard the following notes should be followed: Station should be assembled and installed in accordance with
More informationModel 2000SMS/2000SMSN Bottle Filler with Lifecycle Control
INSTALLATION GUIDE 1455 Kleppe Lane Sparks, NV 89431-6467 (888) 909-4297 website: www.hawsco.com Model 2000SMS/2000SMSN Bottle Filler with Lifecycle Control No. 0510000664 (2) NOTE: A Class A ground-fault
More informationOperator Enclosures. Console Type 12 - AW-14 Data Sheet
Console Data Sheet Construction Console body, panel cover and door, top assembly and writing desk are fabricated from (14) gauge steel ll continuous welded seams are finished smooth Panel cover is secured
More informationProduct Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations
Diverting Valve Three-Way Diverting Valves can be used for temperature control in many heating and snowmelting applications. Valve Cross Section Features Includes solder tailpieces (1-1/4" and 1-1/2" models
More informationOPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies
OPERATION AND INSTRUCTION MANUAL EP Series Battery Chargers and Power Supplies THIS MANUAL IS PUBLISHED BY EPC CORPORATION AND IS TO BE DISTRIBUTED WITH NEW DEVICES ONLY NO OTHER DISTRIBUTION IS PERMITED
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationOperators Manual. Recirculating Chiller /06/08
Operators Manual Recirculating Chiller 110-197 11/06/08 Table of Contents Section 1. General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description of the Recirculating Chiller 1.5
More informationIn This Section Portable Hot Box Aluminum For Transport J ER-18 Enclosed Rack For Display J
J Cabinets In This Section Portable Hot Box J-1...237 ER-18 Enclosed Rack For Display J-2...239 Econoline Cabinets Aluminum For Storage J-3...241 Transport Cabinets J-4...243 Stackable Cabinets J-5...245
More informationProduct Instructions. Mixing Station. Features. Specifications. Materials
Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal
More information2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways
2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways Absolute Control. Optimized Efficiency. Features and Installation Self-cleaning: No filters
More informationMagnum Mobile Generator MMG235 Specifications
Customer Driven Unsurpassed Value Magnum Mobile Generator MMG235 Specifications ENGINE John Deere PE6068HF485 - turbocharged, diesel engine o Prime - 286 hp @ 1800 rpm o Standby - 315 hp @ 1800 rpm o 6
More informationETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL
ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationHot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated
Horizontal or Vertical Jacketed & Insulated Lochinvar s Hot Water Generator Systems are ideal when boiler capacity is sufficiently sized to cover potable hot water demand and provide source water for hydronic
More informationSafety Stations with Eyewash
Safety Stations with yewash F G1942 Safety Station with yewash, Freeze and Scald Protection Valves pplication: ombination eyewash and shower safety station. Unit is furnished with temperature-actuated
More informationmodel 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station
model 2000SN Recessed Wall-Mount Bottle Filling Station FEATURES & BENEFITS QUALITY CONTROL The Haws bottle filling station is pre-built and fully water and pressure tested to ensure no leaks and proper
More informationPRE-INSTALLATION GUIDE
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.
More informationSOLAR HEATING SYSTEM
SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping
More informationMMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4
1 of 5 Generators Isuzu 4LE2XAGV01 - turbocharged, aftercooled diesel engine Prime 57 hp, 42.8kWm @ 1800 rpm Standby 63.7 hp, 47.5 kwm @ 1800 rpm 4 cylinder 2.2 L displacement EPA Tier IV approved and
More informationModel &
PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND
More informationRWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual
P.O. Box 245 Syracuse, NY 13211 www.roth-usa.com info@roth-usa.com 888-266-7684 Table of Contents: RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation
More informationSafety Stations with Eye/Face Wash
Safety Stations with ye/face Wash F G1950 Safety Station with ye/face Wash, Stainless Steel owl pplication: ombination eye/face wash and shower safety station. Two large FS-Plus spray-type outlet heads
More informationHydro-Flow Model 2200 Installation and Operation Guide B
Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical
More informationSelf-Operating Temperature Regulators
Self-Operating Temperature Regulators Remote Bulb for Heating, Cooling, Mixing and By-Pass Applications Powers # Regulators With Powers # Self-Operating Temperature Regulators, you no longer need external
More informationConsider The Possibilities...
FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads
More informationProduct guide. Enclosed NEMA starters. usa.siemens.com/controls
Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction
More informationDWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series
IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160
More informationMagnum Mobile Generator MMG125 Specifications
Empowering Real People Magnum Mobile Generator MMG125 Specifications ENGINE John Deere PE6068TF275 - turbocharged, diesel engine o Prime - 150 hp @ 1800 rpm o Standby - 165 hp @ 1800 rpm o 6 cylinder o
More informationPACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series
6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance
More informationHot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated
Horizontal or Vertical Jacketed & Insulated Hot Water Generator Systems Water to Water to Water Lochinvar s Hot Water Generator Systems are ideal when boiler capacity is sufficiently sized to cover potable
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationMagnum Mobile Generator MMG75 SS Specifications
Empowering Real People Magnum Mobile Generator MMG75 SS Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder o
More informationSeries. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate Coolant
Series Issued April 2013 Index No. AY/7.2 Coolmate Coolant Systems Quick Specs Light/Heavy Industrial Applications Manufacturing Aerospace Automotive Tube Mills Automation Processes TIG (GTAW) MIG (GMAW)
More informationTempControl Thermostatic Water Controllers
Thermostatic Water Controllers TempControl for the Precise and Accurate Control of Tempered or Hot Water Applications A necessity for all general uses and applications where the temperature of generated
More informationProduct guide. Enclosed NEMA starters. Answers for industry.
Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications
More informationDPS. The SSV Dual Pump System
DPS The SSV Dual Pump System A Full Range of Product Features The DPS series of 36L stainless steel vertical multi-stage pumps from G&L has been designed to provide reliable high pressure boosting to serve
More informationand Refrigeration Institute). CNX Special Purpose Contactors
Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors
More informationS19214 Series. Pedestal-Mount Halo Eyewash or Eye/Face Wash. Recommended Option:
Halo Delivers the Most Effective Eye/Face Washdown Coverage and Spray Pattern Exceeds American National Standard Z358.1 Specifications Exceeds European EN 15154-1 & EN 15154-2 Exceeds Australia/New Zealand
More informationEconotrol Series 09 Butterfly Valve 2" thru 14" for 125/150 lb. Flanging
General Description: The PDC "Econotrol" series butterfly valve is available in sizes from 2" thru 14" in a combination of materials and optional features suitable for most mid-range differential pressures
More informationINSTALLATION/OPERATING INSTRUCTIONS TSC
INSTALLATION/OPERATING INSTRUCTIONS TSC Two-Stage Set Point Control with External Activation Two-Stage Heating (Rotation Included) Two-Stage Cooling (Rotation Included) Change-Over Control (Heat/Cool)
More informationMagnum Mobile Generator MMG75 Specifications
Customer Driven Unsurpassed Value Magnum Mobile Generator MMG75 Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder
More informationHydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationFluid Cooling Mobile AOHM / AOVHM Series
Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR
More informationBULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS
BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current
More informationPARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008
EFFECTIVE: MAY, 2008 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2 211-0044L-R
More informationSPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET
SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET DESCRIPTION The SEF-1800-CA Eyesaver faucet combines a gooseneck faucet with
More informationElectric. PN April Series Electric Oven
Electric PN April 2013 Series Electric Oven E NOTICE: This Owner s Operating and Installation Manual should be given to the user. The operator of the oven should be familiar with the operation of the oven.
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Axor Uno 38020XX1 Axor Uno 38025XX1 Axor Uno 38210XX1 Uno Single-control Lavatory Faucet 38020XX1 Uno Single-control Tall Lavatory Faucet 38025XX1 Uno Single-control
More informationIMMERSION FIRED HOT WATER BOILER
918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty 3-Hole Roman Tub Rough 3-Hole Roman Tub Trim Kits 3-Hole Roman Tub Rough 06607000 Technical Information Recommended water pressure 45-80 psi Max. water pressure 145
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary
More informationCopeland Screw TM Compressors
Copeland Screw TM Compressors Mechanical Guidelines for SHL & SHM Models using ESC-201 Control System Contents: Start-Up Procedure Operating Specifications Maintenance Trouble Shooting Guidelines Start-up
More informationProduct Guide. enclosed NEMA STARTERS
Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,
More informationMobile Generator MMG130 Specifications
Mobile Generator MMG130 Specifications ENGINE John Deere PE4045HFG93 - turbocharged, diesel engine o Prime - 152 hp @ 1800 rpm o Standby - 166 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim
More informationMobile Generator MMG75D Specifications
Mobile Generator MMG75D Specifications ENGINE John Deere PE4045HFG92 - turbocharged, diesel engine o Prime - 97 hp @ 1800 rpm o Standby - 107 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim Tier
More informationGUIDE SPECIFICATIONS CE Series Two Stage R-410A
GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall
More informationZP SERIES POSITIVE DISPLACEMENT PUMPS
ZP SERIES POSITIVE DISPLACEMENT PUMPS ZP Series Pumps REDEFINING ENGINEERED EXCELLENCE The ZP Series establishes a new standard of value, quality and features in the positive displacement pump market.
More informationMobile Generator MMG25FHI Specifications
Mobile Generator MMG25FHI Specifications ENGINE Isuzu 4LE1NYGV-03 - naturally aspirated, diesel engine o Prime - 32 hp @ 1800 rpm o Standby - 35 hp @ 1800 rpm o 4 cylinder o 2.2 L displacement o Tier IV
More informationMagnum Mobile Generator MMG175 Specifications
Customer Driven Unsurpassed Value Magnum Mobile Generator MMG175 Specifications ENGINE John Deere PE6068HFG94 - turbocharged, diesel engine o Prime - 217 hp @ 1800 rpm o Standby - 241 hp @ 1800 rpm o 6
More informationAir-Cooled Fluid Cooler
Catalog KM-FSD-0313A FS/ FD Series Air-Cooled Fluid Cooler Consider The Possibilities Cools most any non-corrosive fl uid Closed-circuit cooling avoids contamination Cold weather economizer for interior
More informationClass I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature
More informationCLIMAGUARD Outdoor Heat Exchangers
Product Overview : CLIMAGUARD Outdoor Heat Exchangers TX23 Model TX38 Model TX52 Model 132 Product Overview : Lab- and field-tested to seal out extreme weather CLIMAGUARD Outdoor Heat Exchangers PRODUCT
More informationRotational Wand Mixer LevTech Disposable Mixing System
April 12, 2006 Rotational Wand Mixer LevTech Disposable Mixing System Contents Rotational Wand Mixing System (RWM): Overview, Specifications & Pictures RWM Disposable Mixing Bags: Description & Drawing
More informationSpecification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits
More informationPyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D
SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D 1 HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A fire fighting system shall
More informationSPECIFICATION: OPERATION: (Dimensional drawing on following page)
Electronic Showers Hardwire Operated (86T) - Push button electronic shower system Model No: 86T7 COMPLIES WITH: SPECIFICATION: ASME A.8. / CSA B. Volume Control lever handle ADA compliant to ICC / ANSI
More informationSS902 Safety Station with Eyewash, Stainless Steel Bowl SS902P Safety Station with Eyewash, Plastic Bowl
Safety Stations SS902 Safety Station with Eyewash, Stainless Steel Bowl SS902P Safety Station with Eyewash, Plastic Bowl application: Combination eyewash and shower safety station. Two GS-Plus spray-type
More informationHamilton 3VO Submittal
Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum
More informationJST Series. Cemline STONESTEEL Jacketed Storage Tanks
JST Series Cemline STONESTEEL Jacketed Storage Tanks STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORTION P.O. BOX 55 CHESWICK, PENNSYLVNI 15024 Phone: (724) 274-5430 FX: (724)
More informationSECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING
SECTION 22 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Valves, General 2. Gate Valves 3. Balancing Valves 4. Ball Valves 5. Swing Check Valves 6. Backflow Prevention Assemblies 7. Pressure
More informationTrailer Systems (Gas, Water,& Electric) System View Point
Trailer Systems (Gas, Water,& Electric) Presented At The WBCCI International, Sedalia 2012 Page 1 Look at System View Point Use, Source, Storage, Distribution, Use, Waste Consider Safety System Configuration
More informationCATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL
CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS C24GA6 C24GA10 ML-136056 ML-136057 PRIOR MLS COVERED IN THIS MANUAL C24GA6 C24GA10 ML-136021 ML-136022 For additional information on
More informationInstallation Instructions
Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.
More informationXT SERIES Jockey Pump Controllers Features
XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed
More information07 Oil Change & Diesel Transfer Pumps
064 07 Oil Change & Diesel Transfer Pumps OIL CHAngE PuMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat, because it uses the vessel s own power
More informationCable & Wire Management
Cable & ire Management ay-in ireway Data Sheet Cable & ire Management pplication ouses runs of control and power cable Protects against circulating dust, falling dirt and dripping noncorrosive liquids
More informationMid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106
Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Dry Gauge Design with No Internal Liquid Fill BULLETIN NO. 105-106/12 (SUPERSEDES 105-106/11) Industrial ontrol Over Range Protection
More informationParaffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007
Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Be certain to read this manual thoroughly before proceeding with unpacking and installation. TABLE OF CONTENTS Topic
More informationDuplex Commercial Pressurizer -DCP
Duplex Commercial Pressurizer -DCP Pre-Engineered Two-Pump Booster Reliable, Efficient and Easy Thrush Duplex Commercial Pressurizer Thrush Duplex Commercial Pressurizers are pre-engineered pressure booster
More informationComposite PEX-AL-PEX Tubing
04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192
More informationHOSE BOXES. Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL
HOSE BOXES Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL INTEGRAL STOP NON-FREEZE WALL VALVE & BOX Integral Stop Wall Valve & Box with Non-freeze Protection Typical Applications
More informationLighthouse Power Pedestals,
Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized
More information4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.
4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide
More informationPart Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element
BP500 Tech Sheet Balboa Water Group Part Number: 55697-04 4kW 800 Incoloy Element 55967-03 3kW 800 Incoloy Element 55700-04 With 4kW Titanium Element 55968-03 3kW 800 Titanium Element Compatible Plumbing
More informationIssued April 2018 Index No. AY/7.2 Coolmate Series. Processes TIG (GTAW) MIG (GMAW) Plasma cutting Resistance welding
Issued April 2018 Index No. AY/7.2 Coolmate Series Coolant Systems Quick Specs Light/Heavy Industrial Applications Manufacturing Aerospace Automotive Tube mills Automation Processes TIG (GTAW) MIG (GMAW)
More informationAccessories. UP timer. Timer control. Approvals. UP Series
UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:
More informationInstallation Instructions / Warranty. Starck Semi-Pro
Installation Instructions / Warranty Starck Semi-Pro 10820001 Starck Semi-Pro 10820XX1 2 Technical Data Operating pressure: max. 145 psi Recommended operating pressure:14.5-75 psi Test pressure: 232 psi
More informationSpecification: Industrial Mixing Center
Specification: Industrial Mixing Center Model: IMC40 Article I. General Specifications: Section 1.01 The assembly shall be pre-piped with performance matched components and pressure tested before delivery.
More information