Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element
|
|
- Randolf Morton
- 5 years ago
- Views:
Transcription
1 BP500 Tech Sheet Balboa Water Group Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element Compatible Plumbing Kits (Coupling nuts and seals included) Tailpieces (2-Speed Pump ) Tailpieces (2-Speed Pump ) 5592 Tailpiece Inserts (Circ) 5593 One Direct Circ Pump Coupling and one Tailpiece Insert System Model: BP500 Software ID: M00_200 Software Version: 3.0 Hex File: BP500_3.hex Configuration Signature: AA27 Eng. Project: 3333 Base PCBs / PCBA s: Power Board: 227_B / Logic Board: 222_C / Control Panels: TP Software Version.0 and later Auxiliary Panels AX0A User Interface and Programming Guide:
2 System Revision History Part # EPN Date Originator Changes Made and Balboa Initial Generic Configuration 800 Incoloy and Titanium models Initial release Balboa Minor corrections and clarification. Add J23 / J32 connection for Misc BWG Minor corrections, hardware revs and firmware update BWG Tech Sheet update BWG Software update and configuration update (remove GFCI Test Feature) BWG Wiring Diagram Update to Rev B Power Board and Rev C Logic Board BWG Software update to Version BWG P Low Timeout Update. Add Setup Change Reference Service - Input Power Requirements (Circle Letter Assignment) B 240VAC, 60Hz, 48A, Class A GFCI-protected service (Circuit Breaker = 60A max.), C D A H F Y 4 wires [hot, hot, neutral, ground] 20/240VAC, 60Hz, 6/32A, Class A GFCI-protected service (Circuit Breaker = 20/40A max.), 3 or 4 wires [hot, hot (optional), neutral, ground] 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) 20/240VAC, 60Hz, 6/40A, Class A GFCI-protected service (Circuit Breaker = 20/50A max.), 3 or 4 wires [hot, hot (optional), neutral, ground] 240VAC, 60Hz, 32A, Class A GFCI-protected service (Circuit Breaker = 40A max.), 4 wires [hot, hot, neutral, ground] 20VAC, 60Hz, 6A, Class A GFCI-protected service (Circuit Breaker = 20A max.), 3 wires [hot, neutral, ground] 20/240VAC, 60Hz, 6/48A, Class A GFCI-protected service (Circuit Breaker = 20/60A max.), 3 or 4 wires [hot, hot (optional), neutral, ground] 2
3 Plumbing Fittings 2 Tailpiece kit PN 559. Standard 2 sockets to glue up to 2 PVC pipe. Not Immediately Available..5 Tailpiece kit PN sockets to glue up to.5 PVC pipe with the I.D. Be sure to orient the fittings so that the insert is at the 2:00 position to prevent trapped air. Circ Pump Insert kit PN barb fittings for use with tubing. Be sure to orient the fittings so that the insert is at the 2:00 position to prevent trapped air. Not Immediately Available. Circ Pump Insert kit PN One fitting for direct coupling to the threaded suction of an appropriately-sized circ pump. A barb fitting for use with tubing is used on the other end of the heater. Be sure to orient the fittings so that the insert is at the 2:00 position to prevent trapped air. 3
4 Setup As Manufactured Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC 2-Speed 2A max 20-minute timer for Low Speed, 5 Minutes for High Speed This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Pump 2 240VAC -Speed 2A max 5-minute timer Ozone 240VAC.5A max Uses the same relay as Pump Low Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 2S PUMP J8 RED AC J4 F2 3A 250V S PUMP 2 SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 NOT USED J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS0 Refer to Page 3 to choose a suitable Plumbing Kit. 4
5 Setup 2 Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC -Speed 2A max 5-minute timer Pump 2 240VAC -Speed 2A max 5-minute timer Circ Pump 240VAC -Speed 5A max Programmable Filtration Cycles + Polling This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 240VAC.5A max Uses the same relay as the Circ Pump Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 S PUMP J8 RED AC J4 F2 3A 250V S PUMP 2 SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 CIRC J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS02 Software Configuration Changes based on Default Feature Orig. Setup Changes to J Speed Pump Speed Pump J Not Used (non-circ).....circ Pump Enabled Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 5
6 Setup 3 Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC 2-Speed 2A max 20-minute timer for Low Speed, 5 Minutes for High Speed This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Blower 240VAC -Speed 8A max 5-minute timer Ozone 240VAC.5A max Uses the same relay as Pump Low Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 2S PUMP J8 RED AC J4 F2 3A 250V BLOWER SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 NOT USED J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS03 Software Configuration Changes based on Default Feature Orig. Setup Changes to J4, TP600 Button 2, LED 2, AX0A2.... Pump Blower Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 6
7 Setup 4 Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC -Speed 2A max 5-minute timer Blower 240VAC -Speed 8A max 5-minute timer Circ Pump 240VAC -Speed 5A max Programmable Filtration Cycles + Polling This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 240VAC.5A max Uses the same relay as the Circ Pump Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 S PUMP J8 RED AC J4 F2 3A 250V BLOWER SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 CIRC J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS04 Software Configuration Changes based on Default Feature Orig. Setup Changes to J Speed Pump Speed Pump J4, TP600 Button 2, LED 2, AX0A2.... Pump Blower J Not Used (non-circ).....circ Pump Enabled Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 7
8 Setup 5 Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC 2-Speed 2A max 20-minute timer for Low Speed, 5 Minutes for High Speed This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 240VAC.5A max Uses the same relay as Pump Low Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 2S PUMP J8 RED AC J4 F2 3A 250V S NOT PUMP USED 2 SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 NOT USED J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS05 Software Configuration Changes based on Default Feature Orig. Setup Changes to J4, TP600 Button 2, LED 2, AX0A2.... Pump Not Used Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 8
9 Setup 6 Power Requirements: 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) 4 wires (Hot Line, Hot Line 2, Neutral, Ground) System Ouputs: Pump 240VAC -Speed 2A max 5-minute timer Circ Pump 240VAC -Speed 5A max Programmable Filtration Cycles + Polling This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 240VAC.5A max Uses the same relay as the Circ Pump Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 240VAC Misc. J23 & J32 20VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. WHITE BLACK RED GRN N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF K5 J49 HTR A K3 F5 30A J5 K K6 ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 S PUMP J8 RED AC J4 F2 3A 250V S NOT PUMP USED 2 SENSOR A 4.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 CIRC J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS06 Software Configuration Changes based on Default Feature Orig. Setup Changes to J Speed Pump Speed Pump J4, TP600 Button 2, LED 2, AX0A2.... Pump Not Used J Not Used (non-circ).....circ Pump Enabled Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 9
10 Setup 7 Power Requirements: 20/240VAC, 60Hz, 6/40A, Class A GFCI-protected service (Circuit Breaker = 20/50A max.), 3 or 4 wires [hot, hot (optional), neutral, ground]. Do not use this setup with a 3 kw heater. System Ouputs: Pump 20VAC 2-Speed 2A max 20-minute timer for Low Speed, 5 Minutes for High Speed This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 20VAC.5A max Uses the same relay as Pump Low Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 20VAC or 240VAC Misc. J23 & J32 Not Applicable with 20V Heater. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. GRN GFCI BLK N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 J49 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF ADDED JUMPER FOR 20VAC HEATER SYSTEM REMOVE FOR 240V HEATER K5 K6 HTR A K3 F5 30A J5 K ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 2S PUMP J8 RED AC J4 F2 3A 250V S NOT PUMP USED 2 SENSOR A.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 NOT USED J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS07 Software Configuration Changes based on Default Feature Orig. Setup Changes to J4, TP600 Button 2, LED 2, AX0A2.... Pump Not Used 20v to 240v heater conversion instructions:, Conversion must be performed by a qualified, licensed electrician. 2, Disconnect from power and remove power cord. 3, Completely remove jumper wire between J29 and and discard. 4, Install 240V power conductors; Line, Line 2 and Neutral to main terminal block (TB) Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default 0
11 Setup 8 Power Requirements: 20/240VAC, 60Hz, 6/40A, Class A GFCI-protected service (Circuit Breaker = 20/50A max.), 3 or 4 wires [hot, hot (optional), neutral, ground]. Do not use this setup with a 3 kw heater. System Ouputs: Pump 20VAC -Speed 2A max 5-minute timer Circ Pump 20VAC -Speed.5A max Programmable Filtration Cycles + Polling This is the heater pump and must be the same voltage as the Ozone Must deliver a minimum of 20 GPM through heater Ozone 20VAC.5A max Uses the same relay as the Circ Pump Must be the same voltage as heater pump Spa Light 2VAC On/Off.25A max 4-Hour timer. Light output is rated for LED lighting only - NOT for use with incandescent lights. Heater 20VAC or 240VAC Misc. J23 & J32 Not Applicable with 20V Heater. Wiring Diagram and Settings ON POSITION S SWITCH # OFF POSITION MEMORY RESET* SPECIAL AMPERAGE RULE ON ADD 4 HS PUMPS WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD HS PUMP WITH HEAT TEST MODE ON *SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION. GRN GFCI BLK N L L2 227_B F6 0.A 250V HTR B UNFUSED J44 J48 J J2 J49 STORE SETTINGS* SPECIAL AMPERAGE RULE OFF DON T ADD 4 HS PUMPS W/HTR DON T ADD 2 HS PUMPS W/HTR DON T ADD HS PUMP W/HTR TEST MODE OFF ADDED JUMPER FOR 20VAC HEATER SYSTEM REMOVE FOR 240V HEATER K5 K6 HTR A K3 F5 30A J5 K ALL UNUSED SWITCHES SHOULD BE OFF WHT AC K2 F3 0A 250V J28 J30 J3 J32 J29 J25 J26 J23 K4 J3 J2 S PUMP J8 RED AC J4 F2 3A 250V S NOT PUMP USED 2 SENSOR A.0 kw J57 J20 J6 OZONE J47 SENSOR B J56 CIRC J2 222_C J28 AUX FRZ J29 VAC J7 6 J6 S CONTROL PANEL TO ON H3 K7 J8 J9 AUX TO J5 J30 TST T J5 J3 HCE J26 H2 J25 H LIGHT J5 F4 0.5A 250V WS08 Software Configuration Changes based on Default Feature Orig. Setup Changes to J Speed Pump Speed Pump J4, TP600 Button 2, LED 2, AX0A2.... Pump Not Used J Not Used (non-circ).....circ Pump Enabled 20v to 240v heater conversion instructions: See previous page. Refer to Page 3 to choose a suitable Plumbing Kit. Blue indicates changes from the original Setup default
12 Setup Changes with DIP Switch ON Read and understand these instructions before beginning this process. Know the Setup Number you want before you power up the spa and wait to power up the spa until you re ready to change the Setup Number. The system must be in Test Mode, so move Switch to the ON position. The Test Menu will then be available. Power up the spa, and press any button once to Link the panel. (Note: Switch can be moved to the ON position immediately after power-up, if preferred - Danger! High Voltage will be present!) You will have minute to complete the setup change after you manually exit Priming Mode. (Once familiar with the process, the Setup change should take less than 5 seconds.) As soon as Switch # is placed in the ON position, The temperature will show T after it instead of F or C, indicating the System is in Test Mode J28 AUX FRZ J29 VAC J7 6 J6 S ON DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY! Move DIP Switch (on S on the Logic circuit board) to ON. The system will enter Test Mode. Moving DIP Switch to OFF will exit Test Mode. When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode. You should see ---T where the T indicates the system is in Test Mode. READY RANGE Continued on Next Page. 2
13 Setup Changes Continued Again, You will have minute to complete the setup change after you manually exit Priming Mode. Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay shows the Setup Number (S-0, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset, using the newly-selected Setup from that point on. Move DIP Switch to the OFF position to take the spa out of Test Mode. F or C will replace T. Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field. THIS SYSTEM IS CONFIGURED AS SETUP # NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum. Key Indicates Flashing or Changing Segment Indicates Alternating or Progressive Message - every /2 second A temperature button, used for Action Light or dedicated Choose button, depending on control panel configuration Waiting time - varies depending on function Main Screen READY RANGE FLTR SET RANGE While the Set Temperature is still flashing, press Light TEST will now appear in the LCD first. The System will reset and go into Priming Mode if the Light Button is pressed while anything other than the current setup is flashing. If there is no change to the Setup Number (S-0, S-02, etc.), the display returns to the SETP screen. SET SET SET Several Setups can exist in in this string A dash (--) indicates the current Setup. SET SET When set to ON, Panel will display alternate readings from Senor A and Sensor B on Main Screen Displays Fault Log or SET SET SET SET SET Approx. 5 sec. or SET SET SET SET Approx. 5 sec. Main Screen READY RANGE FLTR *If the Control Panel does not have a Warm (Up) button, but rather a single Temp button, use the Temp button in place of the Warm button in the instruction above. (The flow chart assumes a single Temperature Button.) 3
14 Configuration Options General Features Feature Default Options Increment Pump in Filter Cycle (Circ Only) No Yes, No Pump Low Timer 20 Minutes Between 5 and 240 minutes Minute General Pump Timer 5 Minutes Between 5 and 60 minutes Minute Blower Timer 5 Minutes Between 5 and 60 minutes Minute Mister Timer () 5 Minutes Between 5 and 60 minutes Minute Light Timer 240 Minutes Between 5 and 240 minutes Minute Circ Like P Low See Circ Pump Note Circ Pump can be set with the following functions: 24 hr 24 hr w/3 shutoff Acts like P Low (filters, polls, etc. - Requires a single-speed P) Cleanup Cycle 30 Minutes Between 30 and 240 minutes 30 Minutes - or OFF Cleaup as Preference setting Yes Yes, No Ozone Always Always, Filters/Cleanup Only Ozone Suppression OFF Between 30 and 20 min. Minute - or OFF Pump Purge 60 Seconds Between 30 and 600 seconds 5 Seconds Blower Purge 30 Seconds Between 5 and 300 seconds 5 Seconds Mister Purge () 5 Seconds Between 5 and 300 seconds 5 Seconds Blue Indicates New Custom Configuration Default (Setup ) 4
15 Configuration Options Temperature Features Feature Default Options Increment Temperature Display F C, F All temperatures must be specified in F. The system converts F to C dynamically. If Celsius is required for default settings, choose a desired C value that (after rounding) corresponds to a Fahrenheit value. C F C F Hi-Range Min. Set Temp 80 F Between 50 and 80 F F Hi-Range Max. Set Temp 04 F Between 60 and 04 F F Hi-Range Default Temp* 00 F Between 50 and 04 F F Lo-Range Min. Set Temp 50 F Between 50 and 80 F F Lo-Range Max. Set Temp 99 F Between 60 and 99 F F Lo-Range Default Temp* 70 F Between 50 and 99 F F Freeze Threshold 44 F Between 39 and 54 F F Temp Lock Type Temp + Settings Temp, Temp + Settings Time Features Feature Default Options Increment Time Format* 2 Hour 2 Hour, 24 Hour Filter Start Hour* 8:00 PM (20:00) 00:00 to 23:00 Hour Filter Duration* 2 Hours Between 5 Min and 23:45 5 Minutes -or continuous Filter Cycle 2 Default* OFF OFF, ON Filter 2 Start Hour* 8:00 AM (08:00) 00:00 to 23:00 Hour Filter 2 Duration* 5 Minutes Between 5 Min and 23:45 5 Minutes -or Continuous, or Disabled Light Cycle Disabled Disabled, Enabled Light Cycle Default* OFF OFF, ON Light Cycle Start Hour* 9:00 PM (2:00) 00:00 to 23:00 Hour Light Cycle Duration* 5 Minutes Between 5 Min and 04:00 5 Minutes -or or Disabled *May be changed by end-user (if Enabled) Blue Indicates New Custom Configuration Default (Setup ) 5
16 Configuration Options Reminder Features Feature Default Options Increment Reminders Shown* Yes Yes, No Check ph OFF See Reminder Period Note Days Check Sanitizer OFF See Reminder Period Note Days Clean Filter 30 Days See Reminder Period Note Days Test GFCI 65 Days See Reminder Period Note Days Drain Water 00 Days See Reminder Period Note Days Change Cartridge OFF See Reminder Period Note Days Clean Cover OFF See Reminder Period Note Days Treat Wood OFF See Reminder Period Note Days Change Filter 365 Days See Reminder Period Note Days Reminder Periods can be set between 7 and 80 days. In addition, 365 days can be chosen. Each reminder can be turned OFF individually. Special Features Feature Default Options Increment Special Amperage Rule No Limitation Pump Special Amperage Rule 2 No Limitation Pump to 7 pumps can run on high speed together. Blower can be allowed or suppressed when number of pumps selected is reached. No Limitation does not restrict pump or blower operation. DIP Switch 5 is used to choose Special Amperage Rule or 2. Drain Mode Disabled Disabled, Enabled Demo Mode Disabled Disabled, Enabled Automatic GFCI Test Disabled Disabled, -7 Days Day When GFCI Test is Enabled, the Auto-Test can be set between and 7 days from startup Ozone Slaved to Heater Pump Yes Yes, No *Editable by end-user Blue Indicates New Custom Configuration Default (Setup ) 6
17 Configuration Options Main Control Panel Features Feature Default Options Increment Button Jets See Panel Button Note Button 2 Jets 2 See Panel Button Note Button 3 Flip See Panel Button Note Button 4 Up See Panel Button Note Button 5 Light See Panel Button Note Button 6 Down See Panel Button Note Panel Buttons can be set with the following functions: Unused Up Down Temp Jets Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower Blower 2 Mister Mister 2 Mister 3 Light Light 2 Light 3 Light 4 Fiber Optic Option Option 2 Option 3 Option 4 EitherLight Flip Chooser LED Jets See LED Indicators Note LED 2 Jets 2 See LED Indicators Note LED 3 Light See LED Indicators Note LED 4 Heat ON See LED Indicators Note LED Indicators can be set with the following functions: Unused Heat On Filter Cycle On Lock Jets Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower Blower 2 Mister Mister 2 Mister 3 Light Light 2 Light 3 Light 4 Fiber Optic Option Option 2 Option 3 Option 4 EitherLight TP JETS AUX LIGHT HEAT Download the User Interface and Programming Guide here: Blue Indicates New Custom Configuration Default (Setup ) 7
18 Configuration Options Auxilliary Panel Features Feature Default Options Increment Aux Button A Jets See Aux Button Note Aux Button A2 Jets 2 See Aux Button Note Aux Button A3 Unused See Aux Button Note Aux Button A4 Light See Aux Button Note Aux Buttons can be set with the following functions: Unused Up Down Temp Jets Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower Blower 2 Mister Mister 2 Mister 3 Light Light 2 Light 3 Light 4 Fiber Optic Option Option 2 Option 3 Option 4 EitherLight t Flip Chooser AX0 A No O/L AX0 A2 AUX O/L 5599 AX0 A3 No O/L AX0 A4 No O/L AX20 AA2 No O/L AX20 AA3 No O/L 5280 AX20 AA4 No O/L A A2, 3 or 4 AX40 No O/L A A2 A3 A4 Blue Indicates New Custom Configuration Default (Setup ) 8
GS510SZ Tech Sheet. Balboa Instruments. System PN System Model # GS5-GS510SZ-RCA-3.0 Software Version # 43 EPN # 2765
GS50SZ Tech Sheet Instruments System P 557-0 System Model # GS5-GS50SZ-RCA-.0 Software Version # EP # 765 Base PCBA - P 558-0 PCB GS500Z - P 05 Rev B Base Panels VL700S P 58 VL70S (Serial Standard) P 589-0
More informationWN501Z Tech Sheet MANDERASPA. Winer Spas. System PN System Model # GS5-WN501Z-RCA-3.0 Software Version # 38 EPN # 2854
W50Z Tech Sheet MADERASPA Winer Spas System P 559-0 System Model # S5-W50Z-RCA-.0 Software Version # 8 EP # 85 Base PCBA - P 559 PCB S500Z - P 05 Rev B Base Panels VL0 (LCD Lite Duplex) P 509 VL0 (LCD
More informationMS5000E Mach 3 Hot Sheet
MS5000E Mach 3 Hot Sheet System Model # L2-MS5000E-RCA-3.0k Software Version # 21 EP # 1804 Base PCBA - P 55063 PCB L2000 P 22898 Rev B Base Panels MP700 P 53251-01 Template used: 40597-v21_C.pdf 05/25/2006.pdf
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.
More informationINSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationLingenfelter NCC-002 Nitrous Control Center Quick Setup Guide
Introduction: Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide The NCC-002 is capable of controlling two stages of progressive nitrous and fuel. If the NCC-002 is configured only for nitrous,
More informationTroubleshooting Manual
DISPLAY HOLD/RELEASE SPA AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 Troubleshooting Manual HEATERS POOL SPA SOLAR MENU CANCEL BACK FORWARD ENTER Table of Contents This is the Troubleshooting Manual for
More informationREVISION HISTORY REVISION HISTORY
FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim
More informationVariable Speed Pump and Drive Technical Guide
Variable Speed Pump and Drive Technical Guide 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.56 residential Interface FW 1.01 commercial Table of Contents Safety Precautions Page 1 Installation
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Electric Slide-In Range JES9750AAB/S/W JES9800AAB/Q/S/W JES9860AAB/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing
More informationJPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW
JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW Zodiac Pool Systems, Inc. 1-800-822-7933 Regional Extension www.zodiacpoolsystems.com Zodiac Academy zodiac.academy@zodiac.com www.zodiacacademy.com
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Double Oven Electric Range MER6549BAQ/W MER6769BAQ/W Due to possibility of personal injury or property damage, always contact an authorized technician to service or repair this unit.
More informationProduct manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor
Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and
More informationInstallation Instructions & Users Manual
Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Gas Slide-In Range JGS8750ADB/S/W JGS8850ADB/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this
More informationEXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE
CLEAN MODE Temperature Controller User s manual CURRENT CONDITIONS ROOM TEMPERATURE PROBE TEMPERATURE OUTSIDE TEMPERATURE RELATIVE HUMIDITY STATIC PRESSURE TIME / DATE SETTINGS SET POINT / CURVE MINIMUM
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationPART B BRAND SPECIFIC MANUAL
SPA OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS PART B BRAND SPECIFIC MANUAL ELECTRICAL CONNECTION KEYPAD OPERATION 200 Series 200-M-B-16 Read in conjunction with Part A General Manual to form a complete
More informationGTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM V Gas Turbine Flow Monitor Operation / Installation
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11
Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified
More informationCOAST SPAS TSPA-MP SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.
COAST SPAS TSPA-MP SERVICE MANUAL Gecko Electronics Inc. Visual step-by-step guide to easily identify & correct technical problems! Table of Contents Power & Ground Check Electrical Wiring 4 GFCI 5 Programming
More informationInstallation Suggestions
Installation Suggestions P/N 52200-98 Suggestions For Installing The Balboa 05-28-14 Introduction The Balboa consists of a controller that opens and closes valves that supply water to four groups of jets.
More informationTechnical Service Manual
2004 Technical Service Manual Table of Contents Balboa Control Service Checklist Preface..................................... 4 Tools Required............................... 4 System Components Required....................
More informationMitsubishi. VFD Manuals
Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi
More informationInduction Power Supplies
Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.
More informationTe 803 Electronic Controller. Service, Operation & Technical Information Manual
Te 803 Electronic Controller Service, Operation & Technical Information Manual WARNING! Technical descriptions and data given in this document are accurate, to the best of our knowledge, but can be subject
More informationis10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)
is10 Spa-Side Remote (For IntelliTouch and CP3800 series systems) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationGTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation
More informationRADIO FREQUENCY SYSTEMS
C14520.016-E.MU0 DOC.:10000008168-02 LAB4 DEHYDRATOR USER MANUAL 1 DRYING CHAMBER 2 HEATER 3 PUMP 4 AIR BACKWASHING HOLE 5 HUMIDITY PROBE 6 DIGITAL PRESSURE GAUGE 7 RELIEF VALVE 8 SHUT OFF VALVE 9 DRY
More informationTroubleshooting & Service for GL/GS Systems. 50 Hz
Troubleshooting & Service for GL/GS Systems 50 Hz 1 Balboa s Patented M7 Technology TOPSIDE CTROL PAEL The control panel activates functions at the touch of a button. Each function will echo from the circuit
More informationNon-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.
End User Disclaimer End User Disclaimer: United Spa Controls systems have absolutely no end user serviceable parts. United Spa Controls does not authorize attempts by the spa owner/ user to install or
More informationINOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual
INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A
More informationAquaPure Ei TM Series Replacement Kits
AquaPure Ei TM Series Replacement Kits for Models APURE35/35C WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the
More informationVARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor
VARIABLE SPEED USER MANUAL Premium Efficiency Variable Speed Motor SAFETY Safety is emphasized throughout the user manual. These are safety alert symbols. They alert the user to potential personal injury
More informationBIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL
E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature
More informationOnCommand Troubleshooting Guide Hayward Industries
OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters
More informationProgramming Guide. Futura Spas TMTM. in.k300. in.k300. the essential spa keypad. Bright LCD screen Spa function icons. Spa function icons.
TechBook Programming Guide Futura Spas TMTM in.k300 in.k300 the essential spa keypad 1 Pump Spasspa equipped the essential keypad with Bright LCD screen Bright LCD in.k300 spascreen keypad Spa function
More informationSPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY
AQUATIC ECO-SYSTEMS SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.
Double Oven Electric Range Technical Information MER6765BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer
More informationINSTALLATION/OPERATING INSTRUCTIONS MCP
INSTALLATION/OPERATING INSTRUCTIONS MCP Modulating Digital Set Point Control with Boiler Output and External Activation Temperature Range -30 to 250 F (-35 to 120 C) Pressure Ranges 0-30, 0-100, 0-200PSI
More informationSOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.
AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CONTROLS INC. www.goldlinecontrols.com 888-921-7665 IMPORTANT SAFETY
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MODEL 2180 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many
More informationInstallation and Operation Manual
Installation and Operating Data Installation and Operation Manual Jandy Laminar Jet Pulse Controller LPC4 H0566900A WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion
More informationTIMER INTERFACE USER MANUAL
TIMER INTERFACE USER MANUAL Premium Efficiency Two-Speed Motor with Integrated Timer Formerly A. O. Smith Electrical Products Company A Regal Beloit Company COPYRIGHT Copyright 2011, Regal Beloit EPC,
More informationInlet Controller SB3500 USER'S MANUAL
Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More informationDeclaration of Conformity
Declaration of Conformity We, Manufacturer: Spartanics Ltd. 3605 Edison Place Rolling Meadows, Illinois 60008 Phone: 847-394-5700 Fax: 847-394-0409 USA ENGLISH declare under our sole responsibility that
More informationSMT-150 Installer Manual
SMT-150 Installer Manual 3 Stage Digital HVAC Controller Version 1.0 Version History January 2019 Version 1 - Original Document Thank you for your purchase of this premier product. Please take the time
More informationHayward error codes and troubleshooting
http://waterheatertimer.org/intermatic-trippers-and-parts.html#pool 50 Hayward error codes and troubleshooting Section V. TROUBLESHOOTING http://www.hayward-pool.com/prd/in-ground-pool-manuals_10201_10551_14502_-1
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationBLOWER VACUUM SWITCH FAILED OPEN
F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check
More informationMagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
1 MagicStream Laminar Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 IMPORTANT SAFETY PRECAUTIONS Important Notice: Attention Installer:
More informationCONTENTS ESC CONTENTS... 1 FEATURES... 2 LAYOUT... 3 DISPLAYS... 4 CONNECTIONS... 5 MENU... 6 MESSAGES... 7 SYSTEM OPERATION... 8
CONTENTS ESC CONTENTS... 1 FEATURES... 2 LAYOUT... 3 DISPLAYS... 4 CONNECTIONS... 5 MENU... 6 MESSAGES... 7 SYSTEM OPERATION... 8 1 F EATURES s Engine Status Center (ESC - p/n 105536) provides the pump
More informationMagnetek DSD 412 Drive
DRIVE STARTUP MANUAL Magnetek DSD 412 Drive Induction Motor Installation www.smartrise.us 2601 Fair Oaks Blvd., Sacramento, CA 95864 916.457.5129 Magnetek DSD 412 Drive EQUIPMENT/SETTINGS VERIFICATION
More informationSpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems)
SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE
More informationINSTALLATION/OPERATING INSTRUCTIONS TSC
INSTALLATION/OPERATING INSTRUCTIONS TSC Two-Stage Set Point Control with External Activation Two-Stage Heating (Rotation Included) Two-Stage Cooling (Rotation Included) Change-Over Control (Heat/Cool)
More information4.2 Component Identification
Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Double Oven Electric Range MER6555AAB/Q/W MER6751AAB/Q/S/W MER6755AAB/Q/S/W MER6775AAB/F/N/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized
More informationBegin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A
HIMOTO ZTW Brushless Electronic Speed Control for car or truck Thank you for purchasing ZTW Brushless Electronic Speed Controller(ESC). The ZTW electronic speed control (ESC) is specifically designed for
More informationOPERATING INSTRUCTIONS MCP-MT1
OPERATING INSTRUCTIONS MCP-MT1 MRM PROCOM Pvt Ltd ISO-9001-2008 certified organization Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Double Oven Dual Fuel Range JDR8895AAB/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
More informationVFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors
VFD - Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi
More informationTable of Contents. For latest version, visit:
Table of Contents 1.0 Introduction... 1.0 Overview... 1 3.0 Test Set Controls... 6 3.1 Power... 6 3. Time Display... 6 3.3 Timer Clear Push Button... 6 3.4 Start Push Button and LED... 6 3.5 Stop Push
More informationWater Specialist PR Control Valve Programming and Cover Drawing Manual
Water Specialist PR Control Valve Programming and Cover Drawing Manual Page 2 PR Man u al PR Manual Page 3 Table of Contents PR Front Cover and Drive Assembly...4 OEM General Programming Instructions...5
More informationKEMKRAFT ENGINEERING, INC. MODEL KEI-434 STEERING WHEEL TORQUE TESTER
INSTRUCTIONAL MANUAL STEERING WHEEL TORQUE SYSTEM MODEL KEI-434 REVISION DATE: 14-JANUARY-1998 47650 CLIPPER DR. PLYMOUTH MICHIGAN 48170 (313)414-6500 1 GENERAL DESCRIPTION The KEMKRAFT Model KEI-434 Steering
More informationTable of Contents. Balboa Control Service Checklist. Topside Control Panel. System Description. Panel Messages. Wiring Checks.
50 HzTechnical Service Manual Table of Contents Balboa Control Service Checklist Preface....................................3 Tools Required..............................3 System Components Required...................3
More informationITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine
Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications
More informationIssue 2.0 December EPAS Midi User Manual EPAS35
Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started
More informationECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5
ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller Version 3.5 1 Change History: Feb 01, 2005 Mar 16, 2005 May 22, 2005 May 9, 2006 By request from CCS,
More informationSPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...INSTALLATION NOTES.
SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...INSTALLATION NOTES. PAGE 4...INSTALLATION SCHEMATIC PAGE 5...OPERATING INSTRUCTIONS.
More informationPowerView PV380-R2 Mechanical Configuration
PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive
More informationInstallation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H
Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H USER NOTE: This addendum serves as additional information for Pulsafeeder PULSAR and PULSAR Shadow metering pumps equipped with
More informationRENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813)
VARIABLE SPEED DRIVE RENEWAL PARTS Supersedes: 160.00-RP4 (1012) Form 160.00-RP4 (813) 292 HP 50 HZ, 400VAC (P/N 371-03700-XXX) 351 HP 60 HZ, 460VAC (P/N 371-02767-XXX) 419 HP 50 HZ, 400VAC (P/N 371-03789-XXX)
More informationMERCURY TL. Reference Manual LM-700 Series LAUNDRY DISPENSING SYSTEM. P/N Rev. J
MERCURY TL LAUNDRY DISPENSING SYSTEM Reference Manual LM-700 Series Copyright 2003 Nova Controls, Inc. P/N 20-07665-00 Rev. J i P/N 20-07665-00 Rev. J ii P/N 20-07665-00 Rev. J Table of Contents 1 Theory
More informationGENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439
LS IGNITION CONTROLLER 19355418 Ignition Control for Carbureted LS Series Engines (24x Crankshaft Index/1x Camshaft Index, 58x Crankshaft Index/4x Camshaft Index) Parts Included Quantity Ignition Controller
More informationINTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP
INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 353061
More information! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.
Electric Freestanding Range Technical Information AER5712BA* MER5751BA* MER5752BA* MERH752BA* MERM752BA* Due to possibility of personal injury or property damage, always contact an authorized technician
More informationFlight Systems. Replacement for KASSEC DESCRIPTION
DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationOperation Manual. For technical help please contact Livorsi Marine at or us at
For technical help please contact Livorsi Marine at 4-5- or email us at info@livorsi.com This Operation Manual system is compatible with any Smartcraft, NMEA, J99 or Indmar engine. Livorsi Marine Inc 5
More informationVission 20/20 micro-controller. Operation and service manual
Vission 20/20 micro-controller Operation and service manual Section Title Table of Contents Section Number How To Use This Manual...TOC-8 Section 1 Operational Flow Charts Requirements to Start Compressor...1-1
More informationKEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER
INSTRUCTION MANUAL STEERING WHEEL TORQUE/ INCLINOMETER SYSTEM MODEL KEI-234 W / INTERNAL BARCODE SCANNER REVISION DATE: 17-AUG-1999 1 GENERAL DESCRIPTION... 3 INSTALLATION... 3 SYSTEM SETUP... 4 To change
More information5000TOC Sensor Service Manual
Part No. 84449 5000TOC Sensor Service Manual This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied (other
More informationSTYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS
STYLE 349 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS Australian Only The following is intended to provide the basic instructions for installation, operating and maintenance
More informationVFD. Variable Frequency Drive
VFD Variable Frequency Drive Mitsubishi Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter
More information! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.
Electric Freestanding Range Technical Information MER5875RA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer
More informationSubmersible Pumps Model ST4125D Model ST6125D
OPERATION AND PARTS MANUAL Submersible Pumps Model ST5D Model ST65D Revision #0 (0/05/0) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY
More informationRain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
More informationSection 55 Chapter 6
Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main
More information3200NT Timer Service Manual
Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................
More informationExpansion Signal (XSIG) Card Installation Instructions
Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with
More informationEco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0
Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n 107065-01 Revision 0 May 20, 2016 Contents Introduction 2 Installation Pre-installation 3 Installation Procedure 4 Electrical
More informationInstallation Operation Maintenance ADDENDUM
Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting
More informationPocket Quick. Reference Guide. On the TOSHIBA. R410A - VRF Range of equipment. Addressing / Commissioning
Pocket Quick Reference Guide On the TOSHIBA R410A - VRF Range of equipment Addressing / Commissioning This guide shows the general set-up procedures for the unit, associated controls and accessories. The
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.
Double Oven Electric Range Technical Information MER6875BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer
More informationA419ABG-3C Electronic Temperature Control
Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where
More information