Installation Instructions
|
|
- Maria Clarke
- 5 years ago
- Views:
Transcription
1 Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing or modifying any components will void the warranty. Product No.s & Options Specifications Faucet Installation Electrical Installation - Start-up / Maintenance -8 FAQ s / Troubleshooting 9 Parts 0 Certified to comply with ASME A.8. 0 AS America, Inc. MODEL NUMBERS 77.xx 77B.xx 77.xx 77B.xx 77.xx 77B.xx TE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Selectronic Products visit our website at: or us at: CRTTEAM@americanstandard.com For Parts, Service, Warranty or other Assistance, please call (8) CRT-TEAM / (8) 78-8 (In Canada: ) (In Toronto Area only: ) 07 AS America Inc. M97 Rev.. (/7)
2 CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing or modifying any components will void the warranty. Product No.s & Options Faucet Installation Electrical Installation - Start-up / Maintenance -8 FAQ s / Troubleshooting 9 Parts 0 0 AS America, Inc. MODEL NUMBERS 77.xx 77B.xx 77.xx 77B.xx 77.xx 77B.xx TE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Selectronic Products visit our website at: or us at: CRTTEAM@americanstandard.com For Parts, Service, Warranty or other Assistance, please call (8) CRT-TEAM / (8) 78-8 (In Canada: ) (In Toronto Area only: ) 0 AS America Inc. M97 (8/) Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping. Remove the fitting and loose items from the carton. The illustration below shows all the fittings and loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.. Installation Instructions. Spout Assembly (less mixing) a. Spout Assembly (mixing). Mounting Kit. " and 8" Deck plate (optional, must be ordered separately). Thermostatic Mixing Valve (optional, must be ordered separately). Inline Filter 7. Assembly Parts 8. Battery Back-Up Unit (optional, must be ordered separately) PWRX POWER KITS SOLD SEPARATELY Plug-In AC Hard-Wired AC Multi-AC PK00.WRK PK00.PAC PK00.HAC PK00.MAC DO T REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. a DO T REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. 7 Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & Temperature Limiter Battery Back-Up Kit 8 PK00.BBU 0XTMV070 Deck Plate Mixing Valve 77P.00 77P.800 M97 Rev.. (/7)
3 Roughing-in Dimensions Note: All plumbing and electrical wiring must be installed in accordance with applicable codes, regulations and standards. 7 mm (-7/8") FINISHED WALL OR BACKSPLASH CLEARANCE mm (min) - 7mm (max) (" min - " max) mm (-/") mm mm (-/") (") 8 mm (-7/8") 9 mm (-/") mm (-7/") CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing or modifying any components will void the warranty. 8 mm (-/") 8 mm (-/8") 97 mm (-/") /8" COMPRESSION CONNECTORS RECOMENDED CONTROL BOX OR EQUIVALENT BY OTHERS " (0mm) SQ. X -/" (89mm) DEEP CONTROL BOX Hubbel-RACO # OR EQUAL (BY OTHERS). (Used with Hard-Wired AC Transformer) RECOMMENDED TOOLS.. mm Hex Wrench (Included). Adjustable Wrench. Plumbers Putty or Caulking. Phillips Screwdriver. Tape Measure..0 mm Hex Wrench (Included) Fig. 0' SPOUT ASSEMBLY INSTALLATION; Fig. CAUTION Turn off hot and cold water supplies before beginning Fig. IMPORTANT: Do not use putty when installing faucet without escutcheon.. Make sure O-RING () is installed in spout base. IMPORTANT: Do not use putty when installing faucet without escutcheon.. If installing DECK PLATE () (optional): Apply a bead of putty to bottom edge of PUTTY PLATE (). Install SCREW () into the MOUNTING BASE OF THE FAUCET () and allign SCREW () with HOLE ().. Insert SUPPLY HOSES (), SHANK () and SENSOR CABLE () (only included in base model) through hole in DECK PLATE with PUTTY PLATE () and mounting surface. (OPTIONAL) PUTTY (If required). Assemble RUBBER WASHER (7), BRASS WASHER (8) and THREADED LOCKNUT (9) onto SHANK () from underside of sink or mounting surface. Hand tighten LOCKNUT (9).. Use a screwdriver to tighten SCREWS (0) on LOCKNUT (9). Work your way around LOCKNUT (9), tightening the screws slightly each time until all are snug to ensure even pressure MOUNTING SURFACE 0 TIGHTEN SPIN NUTS IMPORTANT: Do not use sealent on threads M97 Rev.. (/7)
4 ELECTRICAL INSTALLATION Fig. Product Page PWRX (PK00.WRK) Plug-In AC (PK00.PAC) Hard-Wired AC (PK00.HAC) Multi-AC (PK00.MAC) Important: All product with standard battery come with electrical connections preaseambled at the factory. No further action necessary. A PWRX 0 YEAR BATTERY SYSTEM; Fig. BRACKET INSTALLATION PWRK VERSION;. Connect PWRX BATTERY PACK () to SENSOR CABLE ().. Secure the connections by installing into CONNECTOR LOCKING DEVICE () as shown. Rotate the END CAPS () to secure the connection within the CONNECTOR LOCKING DEVICE ().. Determine the mounting location of the PWRX BATTERY PACK () by marking center lines as shown.. Place the BRACKET () on the horizontal center line and mark the location of the mounting holes to be drilled. HORIZONTAL C/L. Using /" diameter drill bit, drill two mounting holes aproximately " deep.. Install the two ANCHORS () provided into the mounting holes. 7. Place the BRACKET () over the ANCHORS () and secure with the SCREWS (7) provided. Do not overtighten. 8. Insert PWRX BATTERY PACK () into BRACKET (). VERTICAL C/L 7 M97 Rev.. (/7)
5 B AC VERSIONS (HARD-WIRED / PLUG-IN POWER SUPPLY); Fig. Fig. Important: Turn off power to outlet or control box.. Connect PLUG-IN AC POWER SUPPLY () or 0' EXTENSION CABLE () if using HARD-WIRED AC TRANSFORMER (7) to SINGLE AC ADAPTER ().. Connect SENSOR CABLE () to the other terminal of the SINGLE AC ADAPTER ().. Connect PLUG-IN AC POWER SUPPLY () to wall outlet, or connect other end of 0' EXTENSION CABLE () to the HARD-WIRED AC TRANSFORMER (7). FOR HARD-WIRED VERSION;. Make Black and White power line connections to HARD-WIRED AC TRANSFORMER (7) and mount into CONTROL BOX (). CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing or modifying any components will void the warranty. WALL OUTLET BLACK & WHITE POWER CONNECTIONS " CONTROL BOX OR EQUIVALENT BY OTHERS () 0' EXTENSION 7 7 CONNECTOR T USED IN THIS INSTALLATION Recommended Control Box or Equivalent by others " (0 mm) SQ. x -/" (89 mm) DEEP ELECTRICAL BOX Hubbel-RACO # OR EQUAL (BY CONTRACTOR). Fig. Unit # (Already Installed) Unit # Unit # Unit # BLACK & WHITE POWER CONNECTIONS MAXIMUM OF UNITS PER TRANSFORMER. 0' MAXIMUM CABLE LENGTH BETWEEN UNITS. C MULTI-AC VERSION (DAISY-CHAIN); Fig. Important: Disconnect the first unit s Multi-AC Adapter from power supply before making daisy-chain connections. Note: For Unit # electrical instructions, refer to Figure (above). For subsequent Units, refer to instructions below.... Connect one end of the 0' EXTENSION () to the available terminal of the previous unit s MULTI-AC ADAPTER (), and the other end to the single terminal of the current unit s MULTI-AC ADAPTER ().. Connect SENSOR CABLE () to either of the two available terminals of MULTI-AC ADAPTER ().. Repeat Steps above for each additional Unit, for a Max. of Units on one AC POWER SUPPLY. M97 Rev.. (/7)
6 Certified to comply with ASME A.8.M 00 American Standard M98808 To learn more about American Standard Faucets visit our website at: or U.S. customer's us at: For Parts, Service, Warranty or other Assistance, (In Toronto Area only: ) D MAKE WATER SUPPLY CONNECTIONS; Fig. Fig.. Turn off hot and cold water supplies before beginning.. Install INLINE FILTER () on each wall supply outlet. Be sure that INLINE FILTER () is inserted in the correct direction. (See Illustration). Connect HOT FLEXIBLE SUPPLY (marked with red stripe) () to INLINE FILTER () on hot water control stop (). Connect COLD FLEXIBLE SUPPLY (marked with blue stripe) () to INLINE FILTER () on cold water control stop (). Use adjustable wrench to tighten connections. Do not over tighten. () INLINE FILTER. Faucet supplies are " long from faucet base. COLD Note; If additional supply length is required, installer must purchase those parts separately. HOT IMPORTANT: Do not use sealent on threads Important; If SUPPLY HOSES (, ) are too long, loop E INSTALL OPTIONAL MIXING VALVE; Fig. Note: An optional Thermostatic Mixing Valve (sold separately) may be installed on faucets 77X.XX & 77X.XX in addition to Above Deck Mixing valve. See setup diagram Fig.. Tee fitting is not supplied with Faucet or Thermostatic Mixing valve and must be purchased separately. If faucet inlet hoses will not reach water supplies, longer hoses must be purchased separately. For complete detailed installation and operating instructions, see installations instructions (No. M98808) supplied with Thermostatic Mixing Valve. MAINTENANCE A HAND WASH SENSOR OPERATION; Fig. REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE. When the Sensor detects a user, the water immediately starts to flow. Water flow will stop. seconds after user is out of sensor range. This Comfort delay allows the user to comfortably move their hands without the water turning off. As a precaution, a Safety Timer will turn off the water, after the sensor has been blocked for 9 seconds. The water will stay off until the blockage is removed from the detection zone. The Comfort and Safety time settings can be adjusted using the Optional Remote Control (0XRCT). Fig. Installation Instructions Fig. SELECTRONIC Thermostatic Mixing Valve 0XTMV Specifications Installation Adjust Temperature Service Replacement Parts TE TO INSTALLER: Please give this manual to the customer after installation. please call (In Canada: ) No. M98808 TEMPERED WATER SUPPLY DETECTION ZONE PROTECTIVE FILM HOT SUPPLY Optional Mixing Valve (Sold Separately) TEE FITTING COLD WATER COLD SUPPLY M97 Rev.. (/7)
7 B REPLACE BATTERY; Fig., 7. Remove COVER SCREW () and lift COVER () off.. Disconnect SENSOR CABLES () and (7) from the BATTERY and SOLEID VALVE. (Fig. 7). Push BATTERY (7) forward and Pull it out. (Fig. ). Replace the new battery with the same placement. (Insert terminal side first) C REPLACE SENSOR; Fig.,, 7 7. Remove COVER SCREW () and lift COVER () off.. Disconnect SENSOR CABLES () and (7) from the BATTERY and SOLEID VALVE. (Fig. 7) 9. Remove the AERATOR RETAINER SCREW () and BODY FIXATION SCREW (). (Do not remove SPOUT TUBE ). FOR ABOVE DECK MIXING FAUCETS Remove FIXATION SCREW (). Pull the HANDLE ASSEMBLY () to remove the shaft from the MANIFOLD (). Fig.. Lift BODY () off of MANIFOLD ().. Remove SENSOR (9) by carefully pushing on the face of the sensor. Once removed, peal the SENSOR ADHESIVE off of the BODY and clean the remaining residue. 7. To install the new SENSOR, peal the paper liner from the double sided tape and carefully place the SENSOR in its original position so that the WIRES point upward. Press and hold the sensor for - 0 seconds to ensure it sticks properly. Note: To prevent damage to the wires, verify that they are tucked inside the hooks which are located on both sides of the sensor. 8. FOR ABOVE DECK MIXING FAUCETS Slide SPOUT () over the MANIFOLD () being careful to avoid interference between the SPOUT TUBE () and SENSOR (9). Tighten the BODY FIXATION SCREW (). Insert HANDLE ASSEMBLY () into the MANIFOLD () and secure it with FIXATION SCREW (). Move the SPOUT TUBE () and AERATOR RETAINER () into position and tighten the AERATOR RETAINING SCREW () to secure the assembly. Reconnect SENSOR CABLES ( and 7) to the BATTERY and SOLEID VALVE. Install COVER () and secure it with COVER SCREW (). Tuck extra lengths of wire in the empty space located above FIXATION SCREW () Fig Slide SPOUT () over the MANIFOLD () being careful to avoid interference between the SPOUT TUBE () and SENSOR (9). Tighten the BODY FIXATION SCREW (). Move the SPOUT TUBE () and AERATOR RETAINER () into position and tighten the AERATOR RETAINING SCREW () to secure the assembly. Reconnect SENSOR CABLES ( and 7) to the BATTERY and SOLEID VALVE. Install COVER () and secure it with COVER SCREW (). Tuck extra lengths of wire in the empty space located above FIXATION SCREW () Fig M97 Rev.. (/7)
8 D CHANGE SENSOR RANGE; Fig.,, 7. Remove the COVER SCREW ().. Remove the COVER ().. Disconnect the BLACK POWER SUPPLY CONNECTOR (7) and reconnect. Fig. 7.. While the SENSOR CONTROL LED (9) is blinking slowly, place your hand - in. (.-0.8mm) in front of the sensor.. When the LED stops blinking and stays ON, move your hand to the desired position and hold in place until the LED begins to blink again.. Once the SENSOR CONTROL LED (9) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 7. Reassemble the COVER () and secure it with COVER SCREW (). E ADJUST HOT LIMIT STOP; Fig., To reduce the amount of hot water that can mix with cold, the installer can adjust hot limit stop (Four different settings).. Rotate LEVER HANDLE () counter-clockwise to its stop position (00% cold).. Remove LEVER SCREW () and pull off the LEVER HANDLE ().. Pull out LIMIT STOP () from the VALVE STEM ().. Rotate LIMIT STOP () between the shaded area and insert back onto VALVE STEM ().. Each notch on the LIMIT STOP () will reduce the amount of hot water by approximately %. For example, the nd notch will have 97% of maximum temp, the rd notch will have 9% and the fourth will be 9%.. Replace LEVER HANDLE (), LEVER HANDLE SCREW () and tighten. F ADJUST MAXIMUM OUTLET TEMPERATURE; Fig.. With the COVER off, the installer can reduce the maximum mixed water temperature by turning the VALVE CAP () clockwise with a screwdriver. WARNING Do not turn the VALVE CAP () More than turn. The maximum mixed water temperature can not be increased due to ASSE 070 requirements. Fig. Fig. G GENERAL CLEANING. Only use a damp, soft cloth to clean the spout and the sensor.. For tougher dirt, use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. CAUTION Do not scratch the sensor when cleaning. Avoid using any abrasives or harsh detergents or chemicals. Fig. 8 M97 Rev.. (/7)
9 TROUBLESHOOTING FLOW CHARTS UNIT DOES T FUNCTION ARE EXTERNAL SUPPLY STOPS OPEN? YES REPEATED DOUBLE FLASH ON SENSOR? RECONNECT BATTERY TO SENSOR. DOES SENSOR FLASH FOR SECONDS? YES REPLACE SOLEID YES OPEN EXTERNAL SUPPLY STOPS. CRITICALLY LOW BATTERY. INSTALL NEW BATTERY. DEAD BATTERY. INSTALL NEW BATTERY. REPEAT. CHECK FOR DAMAGE TO SENSOR WIRE INSULATION. REPLACE SENSOR. WATER IS CONTINUOUSLY RUNNING RECONNECT BATTERY TO SENSOR. DOES SENSOR FLASH FOR SECONDS? CHECK FOR DAMAGE TO SENSOR WIRE INSULATION. REPLACE SENSOR. YES REPLACE SOLEID LOW FLOW ISSUES ARE EXTERNAL SUPPLY STOPS FULLY OPEN? FULLY OPEN EXTERNAL SUPPLY STOPS BY TURNING COUNTER CLOCKWISE. YES CHECK FOR BLOCKAGE INSPECT FILTER ASSEMBLY, AERATOR AND SOLEID VALVE. REMOVE, CLEAN AND INSERT BACK TO ORIGINAL POSITION. HOT LINE FOR HELP For toll-free information and answers to your questions, call: (8) CRT-TEAM / (8) 78-8 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 0:00 a.m. to :00 p.m. EST IN MEXICO IN CANADA (TORONTO ) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of AS America, Inc. 0 To learn more about American Standard Selectronic Products visit our website at: or us at: CRTTEAM@americanstandard.com 9 M97 Rev.. (/7)
10 M A 0. GPM AERATOR M A 0. GPM AERATOR M A. GPM AERATOR M A SCREW NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter MODEL NUMBERS 77.xx 77B.xx 77.xx 77B.xx 77.xx 77B.xx M A SENSOR (FOR 77 SKUS) M A SENSOR (FOR 77B SKUS) M A SOLEID VALVE M A SHAFT A A SPOUT O-RING M9-0070A HOT LIMIT STOP M A LEVER HANDLE PWRX PK00.WRK M A PWRX BATTERY PACK M A HOT/COLD SUPPLY HOSES M A CONNECTOR LOCKING DEVICE M9-0070A BRACKET M A INLINE FILTER FOR 77.XX & 77B.XX REQUIRES () M A INLINE FILTER FOR 77.XX & 77B.XX 77.XX & 77B.XX REQUIRES () 77P00.00 " ESCUTCHEON 77P " ESCUTCHEON M A MOUNTING KIT Appropriate finish code POLISHED CHROME 00 CR-P Lithium Battery 77. Series Plug-In AC PK00.PAC M A CONNECTOR LOCKING DEVICE Hard-Wired AC PK00.HAC M A CONNECTOR LOCKING DEVICE M A SINGLE AC ADAPTER A9-0070A BATTERY V CR-P M A POWER SUPPLY M A SINGLE AC ADAPTER M A POWER SUPPLY M A 0' EXTENSION HOT LINE FOR HELP For toll-free information and answers to your questions, call: (8) CRT-TEAM / (8) 78-8 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 0:00 a.m. to :00 p.m. EST IN MEXICO IN CANADA (TORONTO ) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of AS America, Inc. 07 To learn more about American Standard Selectronic Products visit our website at: or us at: CRTTEAM@americanstandard.com Multi-AC PK00.MAC M A 0' EXTENSION M A MULTI-AC ADAPTER 0 M97 Rev.. (/7)
Installation Instructions
Installation Instructions NextGen Selectronic Integrated Faucet with Optional Above-Deck Mixing & SmarTherm Temperature Limiter CAUTION: Use only American Standard supplied transformers and cable sets.
More informationInstallation Instructions
Installation Instructions SELECTRONIC Integrated Faucet with Above-Deck Mixing CAUTION: Use only American Standard supplied transformers and cable sets. Using non-as supplied cables, or cutting, splicing
More informationInstallation Instructions
Installation Instructions SELECTRONIC Proximity Faucets Cast Spout and Gooseneck Spout Certified to comply with ASME A.8. 0 American Standard 0X.0 0X. MODEL NUMBERS 0X.0 0X. 0X.0 0X. CAUTION: Use only
More informationInstallation Instructions
Installation Instructions SELECTRONIC Moments Proximity Faucets MODEL NUMBERS 0.X 0.X 0B.0X CAUTION: Use only American Standard supplied cable sets. Using non-as supplied cables, or cutting, splicing or
More informationInstallation Instructions
Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Optional 0P00.XXX, " Deck Plate Optional 0P800.XXX, 8" Deck Plate Certified to comply with ASME A.8. 0 AS America, Inc. MODEL
More informationInstallation Instructions
Installation Instructions SERIN Wall Mount Electronic Proximity Lavatory Faucet TE: Please refer to R30 Mounting Kit installation instructions #M4 prior to faucet installation. Certified to comply with
More informationInstallation Instructions
Installation Instructions SERIN Deck Mount Electronic Proximity Lavatory Faucet Certified to comply with ASME A.. 0 American Standard Optional 0P00.XXX, " Deck Plate Optional 0P00.XXX, " Deck Plate 0.
More informationInstallation Instructions
Installation Instructions SELECTRONIC Proximity Integrated Faucet with Optional Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing
More informationInstallation Instructions
Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in
More informationInstallation Instructions
Installation Instructions SELECTRONIC CONCEALED TOILET FLUSH VALVE.,.8 &. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 0B.XX Exposed Back Spud Concealed Back Spud Top Spud CAUTION:
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY CONCEALED URINAL FLUSH VALVE.0, 0. & 0. GPF Certified to comply with ASME A.9. 07 AS America, Inc. MODEL NUMBERS 0B.X0 0B.X0 0B.X0 CAUTION: Use only American
More informationInstallation Instructions
Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M
More informationInstallation Instructions
Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 08 AS America, Inc. MODEL NUMBERS 606B. 606B. 606B.6 606B.7
More informationInstallation Instructions
Installation Instructions SELECTRONIC EXPOSED TOILET FLUSH VALVE AC POWERED PROXIMITY.,.8,.6,.6/. &.8/. GPF Certified to comply with ASME A.9. 0 AS America, Inc. MODEL NUMBERS 6067. 6067. 6067.6 6067.7
More informationInstallation Instructions
Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0., 0., 0. &.0 GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for /" Top Spud Urinals
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls
More informationINSTALLATION INSTRUCTIONS
AVERY ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationInstallation Instructions
Installation Instructions SELECTRONIC PROXIMITY TOILET CONCEALED FLUSH VALVE. &. GPF Certified to comply with ASME A..M 00 AS America, Inc. Concealed Flushometer for -/" Top or Back Spud Bowls MODEL NUMBERS
More informationInstallation Instructions
Installation Instructions for -/" Top Spud Fixtures MODEL NUMBERS 607 Series 707 Series OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: gpm (9.6
More informationINSTALLATION INSTRUCTIONS
BEALE ELECTRONIC PULL-DOWN KITCHEN FAUCET INSTALLATION INSTRUCTIONS 0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationINSTALLATION INSTRUCTIONS PATIENCE
INSTALLATION INSTRUCTIONS PATIENCE 706.8X DUAL CONTROL WIDESPREAD LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure
More informationINSTALLATION INSTRUCTIONS STUDIO S
INSTALLATION INSTRUCTIONS STUDIO S 70.0 MONOBLOCK LAVATORY FAUCET WITH SPEED CONNECT Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationEDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS
EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.80 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions 1662SG SG.222
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm & 2. gpm Installation Instructions 12SG.212 12SG.222 12SG.212 (1.gpm) 12SG.222 (2.gpm) Thank you for selecting American-Standard...the benchmark of fine quality for
More informationInstallation Instructions 1662SG SG.224
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationInstallation Instructions
Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning
More informationInstallation Instructions
ARIANA IN WALL PRESSURE BALANCING BATH AND SHOWER SETS Installation Instructions 0 0 Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions 1662SG SG.223
COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationInstallation Instructions
CLEAN FREESTANDING SINGLE CONTROL BATH FILLER Installation Instructions.9 Thank you for selecting American-Standard... the benchmark of fine quality for over 00 years. To ensure that your installation
More informationInstallation Instructions
COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard
More informationInstallation Instructions Series Series
PORTSMOUTH Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found onlyon American Standard faucets. Recommended
More informationInstallation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain
Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationInstallation Instructions
TIMES SQUARE Spread Lavatory Faucet with Speed Connect Drain Installation Instructions 8.80 8.8 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only
More informationInstallation Instructions
Installation Instructions BEDPAN WASHER For Use with Exposed Flushometer and -/" Top Spud Toilets Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc. M960 607.800 607.8 MODEL NUMBERS
More informationInstallation Instructions
TROPIC Spread Lavatory Faucet with EverClean Finish & SpeedConnect Drain Installation Instructions 708.80 Congratulations on purchasing your American Standard faucet with EverClean finish and Speed Connect
More informationInstallation Instructions
FLUENT Wide Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed
More informationInstallation Instructions
Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationInstallation Instructions
Installation Instructions COMMERCIAL SYSTEM KITS: 1.5gpm & 2.5gpm 1662.224 1662.214 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation
More informationINSTALLATION INSTRUCTIONS
COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE,. GPF Exposed Flushometer for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. M9600 Rev.. MODEL NUMBERS
More informationINSTALLATION INSTRUCTIONS
Flash Shower Valve Rough INSTALLATION INSTRUCTIONS RU0, RU0 RU07, RU08 RU09, RU07E Thank you for selecting American-Standard... the benchmark of fine quality for over 40 years. To ensure that your installation
More informationINSTALLATION INSTRUCTIONS
COMMERCIAL SYSTEM KITS: 1.5 gpm & 2.5 gpm Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ICS Sink with Selectronic IC Faucet* Models: 98., 98.00 & 98.50 Introduction: Thank you for selecting our products...products which have been the benchmarks of fine quality for
More informationSERIN MONOBLOCK LAVATORY FAUCET with
SERIN MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 0.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE with BEDPAN WASHER For Use with -/" Top Spud Toilets 607.860 (.6gpf) 607.80 (.8gpf) Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc.
More informationInstallation Instructions 7024
HAMILTON Centerset Lavatory Faucet with EverClean Finish & Speed Connect Drain Installation Instructions 70 Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationInstallation Instructions
CADET Centerset Lavatory Faucet with Speed Connect Drain Installation Instructions Congratulations on purchasing your American Standard faucet with the Speed Connect Drain, a feature found only on American
More informationInstallation Instructions Series
PORTSMOUTH MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Series 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature
More informationS-9100, S-9200, S-9300, S-9400, S-9700, S-9800
SPEAKMAN COMPANY 1of 18 S-9100, S-9200, S-9300, S-9400, S-9700, S-9800 Series Installation, Maintenance & Operation Instructions SENSORFLO BATTERY or AC POWERED SLIM DESIGN FAUCETS with DIFFERENT OPTIONS
More informationInstallation Instructions
BERWICK / BOULEVARD MONOBLOCK LAVATORY FAUCET with Speed Connect Drain Installation Instructions 70.0 7.0 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature
More informationInstallation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:
Installation Tools - Basin Wrench - Adjustable Wrenches - Pipe Wrench - Screwdriver - Thread Seal Tape - Supply Lines - Protective Goggles - Silicone Sealant - Pliers - Soft Cloth For Model: 673-6809 Single
More informationInstructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: LUGARNO 23580075 (RH-5910) 23580134 (RH-5910L) 1 REV C Restoration Hardware Faucet Product Size Specification Diagram Dimensions are in Inches and Approximation of a Typical
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Randall Single Lever Lavatory and Vessel Faucets Lavatory Model D500C Vessel Model D505C Model D506C Thank you for selecting DXV. To ensure that your installation proceeds smoothly,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Keefe Single Lever Faucet Monoblock Vessel Model D505C Monoblock Model D500C Thank you for selecting DXV. To ensure that your installation proceeds smoothly, please read these
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SHOWN WITH TUB-FILLER SET (NOT INCLUDED) MODEL: VINTAGE 690090 (RH-576L) 690040 (RH-576) REV C Restoration Hardware Diverter Trim Kit Product Size Specification Diagram Dimensions
More informationInstructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.
116874 Chrome less 116864 PVD brushed nickel with 0-K8-CYCH-AD-Z Chrome with 0-K8-CYBN-AD-Z PVD brushed nickel with 0-K8-CNCH-AD-Z Chrome less 0-K8-CNBN-AD-Z PVD brushed nickel less *Image may vary slightly
More informationInstallation Instructions
Reliant Single Control Centerset Lavatory Faucet with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard
More informationInstallation Guidelines
STYLE No. EAXS32 EAXS33 EAXS34 EAXS35 STYLE No. EAHS32 - sold separately EAHS33 - sold separately EAHS34 - sold separately EAHS35 - sold separately 19 1 /4" 8" 9" 9" 3" In the State of Massachusetts, all
More informationAEF-300/300T SERIES SENSOR FAUCET SYSTEMS
Installation and Owner s Manual AEF-300/300T SERIES SENSOR FAUCET SYSTEMS HYBRIDFLO FIXEDFLO HEALTHFLO AEF-300 AEF-301 AEF-302 AEF-303 AEF-304 AEF-306 AEF-307 AEF-320 AEF-321 AEF-322 AEF-323 AEF-300T AEF-302T
More informationBASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No. 0816407 Rev. 5 (05/16)
More informationBattery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST
1A 1B 8 EAF-100/150 I.I. Rev. 0a (11/02) Code No. 0816542 INSTALLATION INSTRUCTIONS ELECTRONIC, SENSOR OPERATED LAVATORY FAUCETS EAF-150 Series Battery Powered Sensor Operated Lavatory Faucets 2 3 7 10
More information2-DOOR LAUNDRY CABINET KIT
2-DOOR LAUNDRY CABINET KIT OWNER S MANUAL QL054 # 6725159 Table of Contents Table of Contents....2 Safety Information....2 Warranty....3 Warranty Claim Procedure....3 Pre-Installation....4 Tools/Materials
More informationLIGATURE RESISTANT SENSOR FAUCET
LIGATURE RESISTANT SENSOR FAUCET PATENT #US D635, 386 #SF370/SAL-5011 INSTALLATION, MAINTENANCE & OPERATION INSTRUCTIONS SENSORFLO BATTERY OR AC POWERED The Ligature Resistant Sensor Faucet was designed
More informationInstallation For Service Only
For Service Only IMPORTANT! Aerada 1100 Series Low Arc Faucet S53-302 Battery Infrared Metering Faucet (Center Shank with 4" Trimplate) THIS SIDE UP! Packing List Read this entire installation manual to
More informationInstallation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Single Lever Vessel Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SHOWN WITH TUB-FILLER SET (NOT INCLUDED) MODEL: MODERN 50040 (RH-656) 5007 (RH-656X) REV C Restoration Hardware Diverter Trim Kit Product Size Specification Diagram Dimensions
More informationREPLACEMENT PARTS Quick Reference Guide
REPLACEMENT PARTS Quick Reference Guide For High Volume Products American Standard Customer Care 1-800-442-1902 2015 AS America, Inc. Printed in the U.S.A. SAH15B138 Effective October 1, 2015 Contents
More informationInstallation Instructions
REPRISE TRIM KIT Installation Instructions 555.0 555.0 T55.0 Thank you for selecting Porcher Products. To ensure that your installation proceeds smoothly--please read these instructions carefully before
More informationEBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets
INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED HAND WASHING FAUCETS EBF-750 I.I. Code No. 0816324 EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets Includes Instructions
More informationPILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT
PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT BEFORE YOU BEGIN NOTES Observe all local plumbing and building codes. Advance planning before installation is crucial. Carefully read the entire instructions
More informationInstallation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Widespread Lavatory Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s L u x u r y F a u c e
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: LUGARNO RH-5960 Restoration Hardware RomanTub Product Size Specification Diagram Recommended Deck Hole Size /4 Diameter Dimensions are in Inches and Approximation of a
More informationALTERNA DECK/BATH-MOUNT BATH FAUCET
R ALTERNA DECK/BATH-MOUNT BATH FAUCET BEFORE YOU BEGIN NOTE Follow only the steps that apply to your installation. Observe all local plumbing and building codes. Advance planning before installation is
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 000 7800 00 MODEL: Modern 000 (RH-600) 00 (RH-600X) 7800 (TRRH-600) REV E Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter
More informationInstallation Kitchen Faucet Filtration System Instructions GXK285JBL
Installation Kitchen Faucet Filtration System Instructions GXK285JBL BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Save these instructions for local inspector s use. IMPORTANT
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: GRAFTON RH-510 1 REV.A Restoration Hardware Balance Pressure Tub /Shower Set Specification Diagram Ensure that the stop ring () is correctly installed, prior to finished
More informationGeo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser
INSTALLATION MANUAL Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser KPF-1702 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 16, 2016 Thank you
More informationROMAN WATERFALL BATHTUB FAUCET
MODEL: S2024CW Version: 1.0 ROMAN WATERFALL BATHTUB FAUCET Dear Valued Customer, SUMERAIN would like to take this opportunity to thank you for purchasing SUMERAIN products. It is our sincere hope that
More information6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE
INSTRUCTION GUIDE STEP-BY-STEP ILLUSTRATED INSTALLATION INSTRUCTIONS TROUBLE SHOOTING & REPAIR TIPS 20 YEAR LIMITED WARRANTY PROPER FINISH CARE Read these instructions carefully before installing your
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS RH-5900L RH-5900 1 MODEL: LUGARNO RH-5900 RH-5900L REV B Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size 1-3/8 Diameter Dimensions are
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: VINTAGE (RH-5700) REV.A Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter Dimensions are in Inches and Approximation
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODEL: BISTRO (RH-500) REV.A Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter Dimensions are in Inches and Approximation
More informationBASYS Infrared Sensor Activated
EFX-1XX SERIES EFX-2XX SERIES 6C 6B 6A 5 3A 4 2 8 16 9 11 17 1 3B 7 PARTS LIST BASYS FAUCETS Item No. Code No. Part No. Description 1. Mid Mount Faucet Assembly Mid Mount Faucet Assembly with Mixer High
More informationINSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need
Model: IS203, IS203-1-X Three Way Thermostatic Valve 3/4 Rough and Trim Set INSTALLATION MANUAL U P C C Compliance: ASME A112.18.1 CSA B125.1 IMPORTANT CONSIDERATIONS This product and other additional
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Contemporary Floor
More informationVentus Single Handle Vessel Bathroom Faucet
INSTALLATION MANUAL Ventus Single Handle Vessel Bathroom Faucet KEF-15000 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 18, 2016 Thank you for your purchase We would
More information5 5 8 " Description Part # Description Part # O-ring. Tee Connector. Widespread Handle * 1.5 GPM Flow Restrictor PM-080
VOGUE COLLECTION WIDESPREAD LAVATORY SET WITH VO HANDLES MODEL: 6520VO10 6520VO PARTS BREAKDOWN 10 18 2 19 1 5 5 11 16 4 17 12 9 8 13 6 13 14 3 14 7 15 7 15 5 5 8 " Description Part # Description Part
More informationSB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:
Instructions for Models: SB-8 SB-8-E What You Need To Know: Tools: Required: *Adjustable Wrench *Groove Joint Pliers *Philips Screwdriver Important Notes: Be sure to read instructions thoroughly before
More informationINSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV
INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF-15300 www.kraususa.com I toll free: 1.800.775.0703 I 2014-2015 Kraus USA Inc. I REV. August 18, 2016 PRIOR TO INSTALLATION Make sure you
More informationAllura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712
Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions Model Numbers SLW-4712 Lavatory faucet with pop-up drain Alternate Finish Code append to part numbers when applicable -STN Satin
More informationBasin Set INSTALLATION INSTRUCTIONS
P22730-00, P22730-LV, P22730-CC, P22730-BC, P22730-GC, P23100-LV, P23200-LV, P23200-RK, P23200-SK, P23200-SL, P24030-CR, P24030-KL, P24030-CL, P24030-RB, P24030-RL 1 of 6 Thank You For Choosing KALLISTA
More informationSAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!
INSTALLATION / OWNER'S MANUAL Single Handle Kitchen Faucet Model # LK500 Important! You choose the flow rate! This faucet ships with an eco-friendly.5gpm flow regulator installed. If you desire higher
More informationInstallation Guide. Single-Control Bath and Shower Trim A K K K 12021
Installation Guide Single-Control Bath and Shower Trim K 12007 K 12014 K 12021 1031258-2-A IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before
More informationSingle Lever Pull-Out Kitchen Faucet
INSTALLATION GUIDE Single Lever Pull-Out Kitchen Faucet KPF-1621 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new Kraus
More informationInstallation Instructions
Instructions Aerada 900 Series Futura Faucet With Battery (BIR) Infrared Control S53-284 4" Centerset/Centershank S53-289 Centerset/Centershank w/plate Table of Contents Pre- Information............2 900
More informationAquila Single Lever Vessel Faucet
INSTALLATION GUIDE Aquila Single Lever Vessel Faucet FVS-13900 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 24, 2017 Congratulations on the purchase of your new Kraus
More informationInstallation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty
TM Limited Lifetime Faucet Warranty fluid warrants its faucets to be free from defects in material and workmanship for as long as the original consumer purchaser owns his or her home.* This warranty applies
More information