Tankless, Inc. Product Catalog 3/29/2018. Commercial & Industrial 3-Phase Water Heaters COMPANY

Size: px
Start display at page:

Download "Tankless, Inc. Product Catalog 3/29/2018. Commercial & Industrial 3-Phase Water Heaters COMPANY"

Transcription

1 Product Catalog 3/29/2018 Commercial & Industrial 3-Phase Water Heaters

2 Feature Comparison comparison of features in our model lines, and against the competition. Features for competing products are based on readily available public information. Recommended applications CF Series Mechanical Where ruggedness is required, but precise temperature is not. CE Series Electronic Where precise temp. and adjustability are required CES Series Safety applications Tepid water for emergency stations per OSH CERO Series Caustic liquids Caustic fluids including reverse osmosis water Competition Keltech Size Range kw kw kw kw kw kw kw Size Range BTU/hr KBTU/hr KBTU/hr KBTU/hr KBTU/hr KBTU/ hr Voltages 3-phase 208, 240, 480 Delta or Wye, 575 V Dynamic Load Balancing for even element wear 3-phase 208, 240, 480 Delta or Wye, 575 V 3-phase 208, 240, 480 Delta or Wye, 575 V 3-phase 208, 240, 480 V Delta or Wye Various 208, 240, 480, 575, 600 V No Yes Yes Yes Yes No Heat exchanger 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel Copper & Brass Plastic Pipe size ¾ 1¼ ¾ 1¼ ¾ 1¼ ¾ 1¼ ¾ 1¼ ½ 1¼ Element sheathing 840 Incoloy 840 Incoloy 840 Incoloy Titanium 840 Incoloy None Temperature range F / C F / C F / C F / C F / C Temperature adjustability Is output temperature measured and displayed? ctivation flow rate None by 1 F by 1 F by 1 F Yes Yes No 0 gpm (constant hot) 3 gpm (optional flow switch) Yes ctual and requested output temperatures shown if unit is over capacity Yes ctual and requested output temperatures shown if unit is over capacity Yes ctual and requested output temperatures shown if unit is over capacity Yes Eemax Various KBTU/hr 208, 240, 480, 575, 600 V 1- & 3-phase F / C Yes NEM3 No NEM 4 0.5, 2.0 gpm 0.5, 2.0 gpm 0.5, 2.0 gpm 1.5 gpm 0.7, 1.0, 2.5 gpm Freeze protection Standard Standard Standard Standard Standard Optional Flow rate (@ 40 psi) Pressure drop (@ 40 psi) Elements individually fused 50 gpm gpm, 4 12 psi, 2 12 psi, gpm, 2 12 psi, gpm, 2 12 psi, gpm 8 40 gpm, dependent on pipe size 4 x psi, dependent on pipe size Yes Yes Yes Yes Yes Yes RS 232 interface No Yes Yes Yes No No Standard enclosure NEM 3 NEM 3 NEM 3 NEM 3 NEM 3 NEM 3 Optional enclosures NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x NEM 4 and 4x Over-temperature protections Warranty Unknown 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 2-year electrical 5-year heat exchanger 1-year electrical 20+ psi 8-year heat exchanger 2-year electrical Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29, 2018

3 Options NEM 4 Enclosure air-tight and water tight NEM 4X Enclosure air-tight and water tight stainless steel Flow Switch Thermostats Electronic Temperature Control (ETC) External Kill Switch Description For three or six element heater including all drains and fittings surrounding the plumbing. Powder-coated white. Includes water-tight window to view the control boards in the electronic models. 24 X 20 X 10 For twelve, eighteen or twenty-four element heater including all drains and fittings surrounding the plumbing. Powder-coated white. Includes water-tight window to view the control boards for the electronic units. 36 x 36 x 12 For three or six element heater including all drains and fittings surrounding the plumbing. Includes water-tight window to view the control boards in the electronic models. 24 X 20 X 10 For twenty four element heater including all drains and fittings surrounding the plumbing. Includes water-tight window to view the control boards in the electronic models. 36 x 36 x 12 llows CF Series units to turn on when water flow exceeds 3 GPM. Energizes control circuit and acts as additional safety against loss of water supply damaging heater. Saves energy if unit is idle for an extended period because water in the chamber will cool to room temperature. CF Series single-temperature thermostats regulate when the unit heats plus provide over-temperature protection. Select an activation temperature of 90, 110, 125, 145, 155, 185, or 200 F, or close to the output temperature of the heater at purchase. Thermostats can be replaced after heater purchase with a thermostat with a different setting. Normally used in recirculation systems to maintain the systems temperature. The customer sets the temperature they want to maintain and the unit will heat until the water entering the unit attains that temperature. The customer also determines how much they want the system temperature to cool before the unit comes on again. They do this by setting a DIFF temperature at 1+ degrees. For example, if you have 200 degree thermostats installed and set the ETC temperature to 185 and the DIFF to 3, the unit will heat at full power and put 200 F water back in to the system until the return water reaches 185 and the unit will shut off. Once the return water reaches 182 the unit will come on again and the cycle will repeat. Mounted to the outside door of a NEM 4 or 4x enclosure and allows the customer to kill power inside the unit by depressing the red button. 316L Stainless CERO models come standard with 316L stainless CERO all RS 232 Interface llows long distance monitoring and operation. CE all CES all CERO all Purge System Latent Heat Disposal System Pumps In explosion risk areas the customer needs to ensure the water heater will not explode in case of an equipment failure. The purge system maintains air pressure from a clean forced air source inside the water heater, ensuring only non-explosive air is inside the heater at all times. When a large heater shuts off in response to reduced water flow, the heating elements are still hot. Without a heat disposal system, this latent heat will raise the water inside the chamber about 15 F, possibly too hot for an eyewash station. This system reduces that unavoidable increase to 6 F. Various pumps are available and can be recommended for all units on a job by job basis pplicable Models CF 12, 15, 18, 24, 27, 36 CE 12, 15, 18, 24, 27, 36 CES 12, 15, 18, 24, 27, 36 CERO 12, 15, 18, 24, 27, 36 CF 81, 90, 108 CE 108, 120, 144 CES all CERO all CF 12, 15, 18, 24, 27, 36 CE 12, 15, 18, 24, 27, 36 CES 12, 15, 18, 24, 27, 36 CERO 12, 15, 18, 24, 27, 36 CF 48, 54, 72, 81, 90, 108 CE 48, 54, 72, 108, 120, 144 CES 48, 54, 72 CERO 48, 54, 72 CF all CF all Temperature setting must be selected when ordering CF all Requires NEM 4 or 4X enclosure Requires NEM 4 or 4X enclosure CF 12 element, 18 element CES 12 element, 18 element ll series and models larm System Visual and audio alarm system for safety applications CF all CES all Mixing Valve vailable for varying output temperatures in ¾ 1¼ sizes ll series and models 2060 Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29,

4 CF Series General Purpose Water Heaters CF Series models are a low technology, reliable way to heat water. They are electromechanical and heat water based on the temperature measured by a thermostat as the water/fluid passes the element. CF Series models are accurate to ±7 degrees F at low flow rates. They are more accurate at higher flow rates, and larger CF models are more accurate than smaller models. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements ctivates on demand but stays hot without flow ensuring immediate hot water on demand Fixed temperature output determined by thermostat Output temperature range Fahrenheit Individually fused elements Output temperature is fixed and based on the thermostat installed Can be used in re-circulation systems with optional electronic temperature control Unique water flow relieves air build-up resulting on increased longevity Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Conforms to NSI/UL-499 Certified to CN/CS E Options NEM 4 and 4x enclosures are available Optional flow switch sets activation to 3 GPM Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29, 2018

5 CF Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Enclosure Size Includes Fittings (W x H x D) CF 12 KW CF 12 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F x 23 x 9 CF 12 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 15 KW CF 15 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 15 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 18 KW CF 18 KW 480 Y 480 Wye , 110, 125, 145, 155, 185, 200 F ¾ x 23 x Delta available at added cost CF 18 KW , 110, 125, 145, 155, 185, 200 F ¾ x 23 x 9 CF 24 KW CF 24 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 24 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 27 KW CF 27 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 27 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 36 KW , 110, 125, 145, 155, 185, 200 F ¾ x 32.5 x 9 CF 48 KW CF 48 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 48 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 54 KW CF 54 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 54 KW CF 54 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 72 KW , 110, 125, 145, 155, 185, 200 F ¾ or x 42 x 9 CF 81 KW CF 81 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 90 KW CF 90 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 108 KW CF 108 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 108 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 25.5 x 36 x 9.25 CF 120 KW CF 120 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 CF 144 KW CF 144 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 CF 144 KW , 110, 125, 145, 155, 185, 200 F 1 or 1¼ 50 X 54 X 12 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CF 12 KW 208, 240, 480 Wye CF 15 KW 208, 240, 480 Wye CF 18 KW 208, 240, 480 Wye or Delta CF 24 KW 208, 240, 480 Delta CF 27 KW 208, 240, 480 Delta CF 36 KW 208, 240, 480 Delta, CF 48 KW 208, 240, 480 Delta CF 54 KW 208, 240, 480 Delta CF 72 KW 208, 240, 480 Delta, CF 81 KW 208, 240, 480 Delta CF 90 KW 208, 240, 480 Delta CF 108 KW 208, 240, 480 Delta, CF 120 KW 208, 240, 480 Delta CF 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29,

6 CE Series General Purpose Electronically-Controlled Water Heaters CE Series electronically-controlled water heaters calculate the amount of energy needed to meet hot water demand by measuring flow rate, then activating the minimum number of elements necessary to satisfy that demand. No energy is used when the unit is idle other than the pilot light. Larger CE Series models are normally used as boiler replacements or very specific process manufacturing applications. Smaller CE Series models are used for hand washing or smaller process applications. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements ctivates on demand at.25 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Four over-temperature protections Dynamic load balancing ensures even element wear Unique water flow relieves air build-up resulting on increased longevity Freeze protection is a standard feature Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Conforms to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. Options NEM 4 and 4x enclosures are available RS 232 interface available to allow remote monitoring and control Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29, 2018

7 CE Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Inches Enclosure Size Includes Fittings (W x H x D) CE 12 KW CE 12 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CE 12 KW ¾ 22.5 x 23 x 7.5 CE 15 KW CE 15 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CE 15 KW ¾ 22.5 x 23 x 7.5 CE 18 KW CE 18 KW 480 Y 480 Wye ¾ 22.5 x 23 x Delta available at added cost CE 18 KW ¾ 22.5 x 23 x 7.5 CE 24 KW CE 24 KW ¾ 22.5 x 32.5 x 7.5 CE 24 KW ¾ 22.5 x 32.5 x 7.5 CE 27 KW CE 27 KW ¾ 22.5 x 32.5 x 7.5 CE 27 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 36 KW ¾ 22.5 x 32.5 x 7.5 CE 48 KW CE 48 KW ¾ or X 44 X 8 CE 48 KW ¾ or X 44 X 8 CE 54 KW CE 54 KW ¾ or X 44 X 8 CE 54 KW ¾ or X 44 X 8 CE 60 KW CE 60 KW ¾ or X 44 X 8 CE 60 KW ¾ or X 44 X 8 CE 72 KW CE 72 KW ¾ or X 44 X 8 CE 72 KW ¾ or X 44 X 8 CE 72 KW ¾ or X 44 X 8 CE 108 KW CE 108 KW ¼ 50 X 36 X 12 CE 120 KW CE 120 KW ¼ 50 X 36 X 12 CE 144 KW CE 144 KW ¼ 50 X 36 X 12 CE 144 KW ¼ 50 X 36 X 12 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CE 12 KW 208, 240, 480 Wye CE 15 KW 208, 240, 480 Wye CE 18 KW 208, 240, 480 Wye or Delta CE 24 KW 208, 240, 480 Delta CE 27 KW 208, 240, 480 Delta CE 36 KW 208, 240, 480 Delta, CE 48 KW 208, 240, 480 Delta CE 54 KW 208, 240, 480 Delta CE 60 KW 208, 240, 480 Delta CE 72 KW 208, 240, 480 Delta, CE 108 KW 208, 240, 480 Delta CE 120 KW 208, 240, 480 Delta CE 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29,

8 CES Series Eyewash & Emergency Shower Water Heaters The CES Series is designed to heat water for emergency eyewash stations and emergency drench showers to meet OSH requirements. CES 12 kw through CES 36 kw units should be used solely for eyewash station applications. Depending on size, they will heat up to 7 gallons per minute by 35 F (20 C) and limit the output temperature to OSH requirements. CES 48 kw through CES 144 kw units will meet OSH requirements for many installations including emergency showers. You must test your incoming water temperature on a cold day to verify the size unit you need to comply with requirements. Only the largest units will be sufficient for temperate climates. Customers should target 85 F for best results and must attain 60 F to meet regulations, which also require at least 20 GPM per minute per shower for 15 minutes to comply, plus the drench station at 3 GPM, plus the eyewash station requirements. Features Meets all OSH and NSI Z requirements NEM 3 enclosures are standard 316L Stainless steel heat exchangers 840 Incoloy sheathing material for the elements ctivates on demand at.25 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Four over-temperature protections Dynamic load balancing ensures even element wear Freeze protection is a standard feature Minimal pressure drop. See charts on website for details Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit tested for 1 hour at full load amp draw Conforms to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. Options NEM 4 and 4x enclosures are available Latent heat disposal system available to ensure output temperature does not rise more than 6 F when flow drops from 20 GPM+ to 2 GPM Purge systems available for use in Class 1 Div 2 areas RS 232 interface available to allow remote monitoring and control Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29, 2018

9 CES Series Products and Capabilities Part Number Voltage kw Full Load mp Draw Temperature Range F (=djustable F=Fixed) Pipe Size Inches Enclosure Size Includes Fittings (W x H x D) CES 12 KW CES 12 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CES 12 KW ¾ 22.5 x 23 x 7.5 CES 15 KW CES 15 KW 480 Y 480 Wye ¾ 22.5 x 23 x 7.5 CES 15 KW ¾ 22.5 x 23 x 7.5 CES 18 KW CES 18 KW 480 Y 480 Wye ¾ 22.5 x 23 x Delta available at added cost CES 18 KW ¾ 22.5 x 23 x 7.5 CES 24 KW CES 24 KW ¾ 22.5 x 32.5 x 7.5 CES 24 KW ¾ 22.5 x 32.5 x 7.5 CES 27 KW CES 27 KW ¾ 22.5 x 32.5 x 7.5 CES 27 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 36 KW ¾ 22.5 x 32.5 x 7.5 CES 48 KW CES 48 KW ¾ or x 44 x 8 CES 48 KW ¾ or x 44 x 8 CES 54 KW CES 54 KW ¾ or x 44 x 8 CES 54 KW ¾ or x 44 x 8 CES 60 KW CES 60 KW ¾ or x 44 x 8 CES 60 KW ¾ or x 44 x 8 CES 72 KW CES 72 KW ¾ or x 44 x 8 CES 72 KW ¾ or x 44 x 8 CES 72 KW ¾ or x 44 x 8 CES 108 KW CES 108 KW ¼ 50 x 36 x 12 CES 120 KW CES 120 KW ¼ 50 x 36 x 12 CES 144 KW CES 144 KW ¼ 50 x 36 x 12 CES 144 KW ¼ 50 x 36 x 12 3-Phase Voltages vailable kw GPM heated by 40 F ssumes 85 F output with 45 F input GPM heated by 35 F ssumes 80 F output with 45 F input GPM heated by 25 F ssumes 70 F output with 45 F input Maximum water flow at 40 PSI ES 12 KW 208, 240 (Single Phase) CES 12 KW 208, 240, 480 Wye CES 15 KW 208, 240, 480 Wye CES 18 KW 208, 240, 480 Wye or Delta CES 24 KW 208, 240, 480 Delta CES 27 KW 208, 240, 480 Delta CES 36 KW 208, 240, 480 Delta, CES 48 KW 208, 240, 480 Delta CES 54 KW 208, 240, 480 Delta CES 60 KW 208, 240, 480 Delta CES 72 KW 208, 240, 480 Delta, CES 108 KW 208, 240, 480 Delta CES 120 KW 208, 240, 480 Delta CES 144 KW 208, 240, 480 Delta, Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29,

10 CERO Series Caustic Fluid Heaters CERO Series models have titanium sheathed elements that will last longer in a caustic environment than standard Incoloy sheathed elements. CERO Series are electronically-controlled water heaters that calculate the amount of energy needed to meet hot water demand, then activating the minimum number of elements necessary to satisfy that demand. No energy is used when the unit is idle other than the pilot light. Features NEM 3 enclosures are standard 316L Stainless steel heat exchangers Titanium sheathing for the elements ctivates on demand at.25 GPM Output temperature range Fahrenheit ctual and customer requested output temperatures viewable through window in the front panel Rocker switch on outside of unit adjusts temperature in one degree increments Individually fused elements Easily serviced on site ll machining, welding, assembly, and testing done in Sarasota, Florida Each unit is tested at full and partial load MP draw to ensure measurement accuracy and proper operation Options NEM 4 and 4x enclosures are available RS 232 interface available to allow remote monitoring and control 316 stainless steel heat exchangers available Conforms Tested to to NSI/UL-499 Certified to Can/CS Std. C22.2 No. 88. mp Draw Dimensions Output Fittings Standard 208 V 240 V 480 V 575 V Max. Width Height Depth Shipping Shipping BTU/hr Enclosure Operating Pressure Weight Mode CERO 18 kw 61,416 ¾ NEM UPS Custom Carton CERO 27 kw 92,124 ¾ NEM UPS Custom Carton CERO 36 kw 122,832 ¾ NEM UPS Custom Carton Mounting Wall Brackets Wall Brackets Wall Brackets CERO 54 kw 182,248 ¾ or 1 NEM Skid Wall Brackets CERO 72 kw 245,664 ¾ or 1 NEM Skid Wall Brackets 3-Phase Voltages vailable kw GPM heated by 40 F GPM heated by 60 F GPM heated by 80 F Maximum water flow at 40 PSI CERO 18 KW 240, 480 Wye CERO 27 KW 240, 480 Delta CERO 36 KW 240, 480 Delta CERO 54 KW 240, 480 Delta CERO 72 KW 240, 480 Delta Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29, 2018

11 Engineering Specifications Power Inlet/Outlet Heat Number Element Recommended Breakers and Full Load mp Draw 1 Output Size Weight Enclosure Dimensions Output of Size 208 V 240 V of Model inches pounds width height depth btu/hr Elements watts breaker amp breaker amp breaker amp breaker amp draw draw draw draw 12 kw ¾ , kw ¾ , kw ¾ , kw ¾ , kw ¾ , kw ¾ kw ¾ or , kw ¾ or , kw ¾ or , kw ¾ or , kw 1 or 1¼ ¼ 225 9¼ 276, or 24 or 48 or kw 1 or 1¼ ¼ 22¼ 9¼ 307, or 24 or 48 or kw 1 or 1¼ ¼ 22¼ 9¼ 368, or 350 or 24 or 48 or 12 or kw 2 1¼ , kw 2 1¼ , ssumes individually fused elements. Units made after 1/1/15 have individual fused elements. Units made prior to 1/1/15 have the maximum breaker size shown on the front cover label. Check local code for breaker size in your area kw & 144 kw models can be ordered in a 36x36x12 NEM 3 enclosure. Flow Rate vs Temp. Rise Power Flow Rate Temperature Rise degrees Fahrenheit Output gallons/hr. of Model gallons/min kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph kw gpm gph ssumes 1¼ pipe size ll Tankless Inc. water heaters can be plumbed individually or in manifold to create larger systems Whitfield Park ve Sarasota Fl tankless fax info@hotwaterheater.com March 29,

12 2060 Whitfield Park ve Sarasota Fl tankless fax Due to our continuous process of engineering and technological advancement, specifications may change without notice.

Tankless Inc. Product Catalog 6/26/2018. Commercial & Industrial 3-Phase Water Heaters. Commercial & Industrial 3-Phase Water Heating COMPANY

Tankless Inc. Product Catalog 6/26/2018. Commercial & Industrial 3-Phase Water Heaters. Commercial & Industrial 3-Phase Water Heating COMPANY Product Catalog 6/26/2018 Commercial & Industrial 3-Phase Water Heaters Feature Comparison comparison of features in our model lines, and against the competition. Features for competing products are based

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction SPECIFICATIONS 6 to 480 kw and higher CIRCULATION HEATERS CH & CHP SERIES Flanged construction 208 volt through 575 volt, 3 phase 5 to 40 watts/in 2 and higher NEMA 4/12 Terminal housing DESCRIPTION Type

More information

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas

More information

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications Ruud Commercial Gas Universal Water Heaters Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications Features & Benefits The tighter the commercial

More information

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL INSTALLATION AND OPERATION MANUAL HUR 8X170FL HUR 5X170FL HUR 3X170FL HUR 1X170FL Harmsco Filtration Products With Patented Up-Flow and Tangential/Rotational

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas

More information

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations Diverting Valve Three-Way Diverting Valves can be used for temperature control in many heating and snowmelting applications. Valve Cross Section Features Includes solder tailpieces (1-1/4" and 1-1/2" models

More information

Operators Manual. Recirculating Chiller /06/08

Operators Manual. Recirculating Chiller /06/08 Operators Manual Recirculating Chiller 110-197 11/06/08 Table of Contents Section 1. General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description of the Recirculating Chiller 1.5

More information

Specification: Industrial Mixing Center

Specification: Industrial Mixing Center Specification: Industrial Mixing Center Model: IMC40 Article I. General Specifications: Section 1.01 The assembly shall be pre-piped with performance matched components and pressure tested before delivery.

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

Copeland Screw TM Compressors

Copeland Screw TM Compressors Copeland Screw TM Compressors Mechanical Guidelines for SHL & SHM Models using ESC-201 Control System Contents: Start-Up Procedure Operating Specifications Maintenance Trouble Shooting Guidelines Start-up

More information

WATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential

WATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential WATTS/Taras Water Treatment Valves and Accessories Residential Commercial Taras Valve Company, a division of Watts Industries, has been manufacturing quality by-pass valves and accessories for the Water

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

Single-Valve Powerstation

Single-Valve Powerstation Single-Valve Powerstation Description Powerstation is a complete, fully assembled water tempering system, designed to provide safe water throughout commercial and institutional facilities. Powerstation

More information

Secondary Coolant 301

Secondary Coolant 301 Secondary Coolant 301 Instructor Rusty Walker Hill PHOENIX Learning Center Secondary Coolant 301 Start-Up Procedures Secondary Coolant 301 Objectives Describe the initial startup procedures for a medium

More information

Series T2000 Wall Mounted Emergency Eye & Eye/Face Wash

Series T2000 Wall Mounted Emergency Eye & Eye/Face Wash Series T2000 Wall Mounted Emergency Eye & Eye/Face Wash In order to comply with the NSI Z358.1 Standard the following notes should be followed: Station should be assembled and installed in accordance with

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

TempControl Thermostatic Water Controllers

TempControl Thermostatic Water Controllers Thermostatic Water Controllers TempControl for the Precise and Accurate Control of Tempered or Hot Water Applications A necessity for all general uses and applications where the temperature of generated

More information

This catalog contains the following geothermal accessory products and specification guides:

This catalog contains the following geothermal accessory products and specification guides: f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat

More information

IntelliPro VS-3050 Variable Speed Swimming Pool Pump. Quick-Start Guide. Step-by-step instructions for easy set-up and operation

IntelliPro VS-3050 Variable Speed Swimming Pool Pump. Quick-Start Guide. Step-by-step instructions for easy set-up and operation IntelliPro VS-3050 Variable Speed Swimming Pool Pump Quick-Start Guide Step-by-step instructions for easy set-up and operation Table of Contents PAGE 1 Before You Get Started 2 The Performance Secret 4

More information

Safety Stations with Eyewash

Safety Stations with Eyewash Safety Stations with yewash F G1942 Safety Station with yewash, Freeze and Scald Protection Valves pplication: ombination eyewash and shower safety station. Unit is furnished with temperature-actuated

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated Horizontal or Vertical Jacketed & Insulated Lochinvar s Hot Water Generator Systems are ideal when boiler capacity is sufficiently sized to cover potable hot water demand and provide source water for hydronic

More information

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Dry Gauge Design with No Internal Liquid Fill BULLETIN NO. 105-106/12 (SUPERSEDES 105-106/11) Industrial ontrol Over Range Protection

More information

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY

More information

Hamilton 3VO Submittal

Hamilton 3VO Submittal Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum

More information

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom) OWNER S MANUAL Model: UTL-60-12V (5301347) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom) Technical Specifications 60 Gal. Corrosion-Resistant Polyethylene Tank Deluxe Pistol-Grip Handgun w/25

More information

Magnum Mobile Generator MMG235 Specifications

Magnum Mobile Generator MMG235 Specifications Customer Driven Unsurpassed Value Magnum Mobile Generator MMG235 Specifications ENGINE John Deere PE6068HF485 - turbocharged, diesel engine o Prime - 286 hp @ 1800 rpm o Standby - 315 hp @ 1800 rpm o 6

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

Operator Enclosures. Console Type 12 - AW-14 Data Sheet

Operator Enclosures. Console Type 12 - AW-14 Data Sheet Console Data Sheet Construction Console body, panel cover and door, top assembly and writing desk are fabricated from (14) gauge steel ll continuous welded seams are finished smooth Panel cover is secured

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions OWNER S MANUAL Model: FSUTV-45-12V (5302903) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications 45 Gal. Corrosion-Resistant Polyethylene Tank Deluxe Pistol-Grip Handgun 25 Ft. Handgun

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4 1 of 5 Generators Isuzu 4LE2XAGV01 - turbocharged, aftercooled diesel engine Prime 57 hp, 42.8kWm @ 1800 rpm Standby 63.7 hp, 47.5 kwm @ 1800 rpm 4 cylinder 2.2 L displacement EPA Tier IV approved and

More information

Booster Pump Control Valve

Booster Pump Control Valve MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control

More information

SOLAR HEATING SYSTEM

SOLAR HEATING SYSTEM SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping

More information

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies OPERATION AND INSTRUCTION MANUAL EP Series Battery Chargers and Power Supplies THIS MANUAL IS PUBLISHED BY EPC CORPORATION AND IS TO BE DISTRIBUTED WITH NEW DEVICES ONLY NO OTHER DISTRIBUTION IS PERMITED

More information

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated Horizontal or Vertical Jacketed & Insulated Hot Water Generator Systems Water to Water to Water Lochinvar s Hot Water Generator Systems are ideal when boiler capacity is sufficiently sized to cover potable

More information

Manual Transfer Switch

Manual Transfer Switch Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal

More information

Self-Operating Temperature Regulators

Self-Operating Temperature Regulators Self-Operating Temperature Regulators Remote Bulb for Heating, Cooling, Mixing and By-Pass Applications Powers # Regulators With Powers # Self-Operating Temperature Regulators, you no longer need external

More information

Magnum Mobile Generator MMG125 Specifications

Magnum Mobile Generator MMG125 Specifications Empowering Real People Magnum Mobile Generator MMG125 Specifications ENGINE John Deere PE6068TF275 - turbocharged, diesel engine o Prime - 150 hp @ 1800 rpm o Standby - 165 hp @ 1800 rpm o 6 cylinder o

More information

In This Section Portable Hot Box Aluminum For Transport J ER-18 Enclosed Rack For Display J

In This Section Portable Hot Box Aluminum For Transport J ER-18 Enclosed Rack For Display J J Cabinets In This Section Portable Hot Box J-1...237 ER-18 Enclosed Rack For Display J-2...239 Econoline Cabinets Aluminum For Storage J-3...241 Transport Cabinets J-4...243 Stackable Cabinets J-5...245

More information

Safety Stations with Eye/Face Wash

Safety Stations with Eye/Face Wash Safety Stations with ye/face Wash F G1950 Safety Station with ye/face Wash, Stainless Steel owl pplication: ombination eye/face wash and shower safety station. Two large FS-Plus spray-type outlet heads

More information

Bourdon Tube Type Differential Pressure Gauge & Switches Model 109

Bourdon Tube Type Differential Pressure Gauge & Switches Model 109 BULLETIN NO. 109/11 (SUPERSEDES BULLETIN NO. 109/05) Bourdon Tube Type Differential Pressure Gauge & Switches Model 109 LOKED LOGI LRM ONTROLS (vailable with 1 or 2 switches for alarm & control) Over Range

More information

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

Magnum Mobile Generator MMG75 SS Specifications

Magnum Mobile Generator MMG75 SS Specifications Empowering Real People Magnum Mobile Generator MMG75 SS Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder o

More information

Accessories. UP timer. Timer control. Approvals. UP Series

Accessories. UP timer. Timer control. Approvals. UP Series UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:

More information

08 general Purpose Pumps

08 general Purpose Pumps 070 08 general Purpose Pumps InTRODuCTIOn Ballast Pumps Today s Wakeboard and Ski tow boats need to be able to take on water ballast to modify their wake formation. A development of our tried and tested

More information

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS TRANSFER PUMP INSTRUCTIONS P/N 14251NOS A5048-SNOS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death

More information

Magnum Mobile Generator MMG75 Specifications

Magnum Mobile Generator MMG75 Specifications Customer Driven Unsurpassed Value Magnum Mobile Generator MMG75 Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current

More information

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Be certain to read this manual thoroughly before proceeding with unpacking and installation. TABLE OF CONTENTS Topic

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

IL8 Series. Medium Pressure Filters

IL8 Series. Medium Pressure Filters Medium Pressure Filters 6 Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

IL8 Series. Medium Pressure Filters

IL8 Series. Medium Pressure Filters Medium Pressure Filters Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing

More information

Mobile Generator MMG130 Specifications

Mobile Generator MMG130 Specifications Mobile Generator MMG130 Specifications ENGINE John Deere PE4045HFG93 - turbocharged, diesel engine o Prime - 152 hp @ 1800 rpm o Standby - 166 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim

More information

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) OWNER S MANUAL Model: TR-40-EX (5301338) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications 40 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump,

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306)

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306) INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Axiom Industries Ltd. 2615 Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) 651-1815 Fax: (306) 242-3373

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

Mobile Generator MMG75D Specifications

Mobile Generator MMG75D Specifications Mobile Generator MMG75D Specifications ENGINE John Deere PE4045HFG92 - turbocharged, diesel engine o Prime - 97 hp @ 1800 rpm o Standby - 107 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim Tier

More information

Mobile Generator MMG25FHI Specifications

Mobile Generator MMG25FHI Specifications Mobile Generator MMG25FHI Specifications ENGINE Isuzu 4LE1NYGV-03 - naturally aspirated, diesel engine o Prime - 32 hp @ 1800 rpm o Standby - 35 hp @ 1800 rpm o 4 cylinder o 2.2 L displacement o Tier IV

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

Magnum Mobile Generator MMG175 Specifications

Magnum Mobile Generator MMG175 Specifications Customer Driven Unsurpassed Value Magnum Mobile Generator MMG175 Specifications ENGINE John Deere PE6068HFG94 - turbocharged, diesel engine o Prime - 217 hp @ 1800 rpm o Standby - 241 hp @ 1800 rpm o 6

More information

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 158-16-A75 158-16-E75 APPLICATION: Multi-fixture Marine fresh water pump installation. This pump

More information

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F 1000 Series Neptune Booster Systems Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F 140 Years of Pump Manufacturing American-Marsh Pumps, one of the oldest pump lines in America, are pump

More information

MRC 150/300 USER MANUAL. 1 Laird Technologies

MRC 150/300 USER MANUAL. 1   Laird Technologies MRC 150/300 USER MANUAL 1 www.lairdtech.com Laird Technologies THR-UM-MRC150-300 0912 Americas: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 clv.customerpos@lairdtech.com 2 www.lairdtech.com

More information

2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways

2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways 2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways Absolute Control. Optimized Efficiency. Features and Installation Self-cleaning: No filters

More information

Fluid Cooling Mobile AOHM / AOVHM Series

Fluid Cooling Mobile AOHM / AOVHM Series Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR

More information

3-WAY MIXING, BRONZE BODY

3-WAY MIXING, BRONZE BODY HEAVY DUTY BRONZE GLOBE CONTROL VALVES WM 3-WAY MIXING, BRONZE BODY 1/2, 3/4, 1, 1-1/4, 1-1/2, and 2 Screwed NPT Ends ANSI Class 125 or 250 Body Rating ANSI Class IV Close off Bronze Trim with EP or Teflon

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom) OWNER S MANUAL Model: UTV-65-BL (5302843) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom) Technical Specifications 65 Gal. Corrosion-Resistant Polyethylene Tank Deluxe Pistol-Grip Handgun 25 Ft.

More information

FLUID COOLING Shell & Tube EK Series

FLUID COOLING Shell & Tube EK Series FLUID COOLING Shell & Tube Series COPPER & STEEL CONSTRUCTION Features Compact Size High Efficiency Finned Bundle Design Low Cost Optional Patented Built-in Surge-Cushion Relief Bypass 3/16 Tube Size Heat

More information

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 5300936 MODEL: ATV-15-2 12 Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 2.1 G.P.M. Pressure Gauge-Adjustable Pressure Range 15 Foot Handgun Hose 2 Nozzle Boom Assembly

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer) OWNER S MANUAL Model: LG-30-TRL (5302317) (30 Gallon Lawn & Garden Trailer Sprayer) Technical Specifications 30 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump, 2.1 g.p.m. 60 psi 15 Ft.

More information

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor.

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor. IN-BAY INSTALLATION 1) Set up transit or level to determine highest point on the floor. From this point establish a level line from which to mark the bracket height on the walls. 2) Mark wall at 5 10 for

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

Rotational Wand Mixer LevTech Disposable Mixing System

Rotational Wand Mixer LevTech Disposable Mixing System April 12, 2006 Rotational Wand Mixer LevTech Disposable Mixing System Contents Rotational Wand Mixing System (RWM): Overview, Specifications & Pictures RWM Disposable Mixing Bags: Description & Drawing

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL 62545 Telephone: 217 / 364-4467 Fax: 217 / 364-4494 OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS WHAT TO DO FIRST Upon receiving your new pump set system

More information

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW) MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW) Installation, Operation, and Maintenance Manual REV. "B" REV. "C" PLEASE READ ENTIRE DOCUMENT BEFORE PROCEEDING WITH INSTALLATION Energy Saver has

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Mobile Generator MMG130 Specifications

Mobile Generator MMG130 Specifications Mobile Generator MMG130 Specifications ENGINE John Deere PE4045HFG93 - turbocharged, diesel engine o Prime - 152 hp @ 1800 rpm o Standby - 166 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim

More information

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element BP500 Tech Sheet Balboa Water Group Part Number: 55697-04 4kW 800 Incoloy Element 55967-03 3kW 800 Incoloy Element 55700-04 With 4kW Titanium Element 55968-03 3kW 800 Titanium Element Compatible Plumbing

More information

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate Coolant

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate Coolant Series Issued April 2013 Index No. AY/7.2 Coolmate Coolant Systems Quick Specs Light/Heavy Industrial Applications Manufacturing Aerospace Automotive Tube Mills Automation Processes TIG (GTAW) MIG (GMAW)

More information