Medium Voltage products. Indoor disconnectors OWD and OWIII

Size: px
Start display at page:

Download "Medium Voltage products. Indoor disconnectors OWD and OWIII"

Transcription

1 Medium Voltage products Indoor disconnectors OWD and OWIII

2

3 Contents Introduction... Indoor disconnectors type OWD... Indoor disconnectors -poles type OWIII... Manual operating mechanisms type NRWO-...0 Motor operating devices type UEMC 0_... Electromagnetic interlock type NO... Indoor disconnectors OWD and OWIII

4 Introduction ABB indoor disconnectors, type OWD and OWIII are meant for closing and opening electrical circuits in currentless state. In open position, they make a visible and safe isolating gap in the circuit which cuts off the circuit from the side of the power supply. These disconnectors may work in horizontal and vertical position, in one, two and three pole versions depend of apparatus type. ABB offers wide range indoor disconnectors: Rated voltages:, kv Rated normal currents: A Rated short-time withstand current s up to 80 ka Indoor disconnectors OWD and OWIII

5 Indoor disconnectors type OWD. Operating conditions The disconnectors type OWD are to be installed indoors under the following conditions: a) the ambient temperature range for standard model N: 8 K (, +0 C) for tropical model T: 8 8K (, + C) b) the relative humidity for standard model N: 70% at 0K (+0 C) for tropical model T: 8% at 0K (+0 C) c) maximum altitude for installation (above sea level): 000 m.. Designations and switch types The structure of product marking is presented below: OWD 0 w. 0 / located on the permanent contacts with or screws (depending on the rated current). Disconnectors type OWD are adapted to operate in horizontal or vertical position. Disconnectors for rated voltages, kv and higher may be operated manually by means of the manual operating mechanisms (HE, NRWO-) or by means of motor operating devices type UEMC0A_ (mounted on the front panel of the cubicle), UEMC0K (mounted on the disconnector s base), pneumatic operating mechanism type NP8. Disconnectors for rated current, kv by means of the manual operating mechanism, motor drive type UEMC0A_ or an insulating stick. When driven by an insulating stick and UEMC0K they should be situated vertical only. Type Number of poles one two three Rated voltage 0, kv 0, kv 0 kv 0 kv Rated current w A (N) 0 A (T) w A (N) 000 A (T) w A (N) w A (N, T) Type of operating mechanism or pole distance (specified only for non-standard distances) with lever for coupling with manual operating mechanism NRWO or an isolating rod for, kv disconnectors, pneumatic operating mechanism type NP8 on the right hand side, pneumatic operating mechanism type NP8 on the left hand side, two pneumatic operating mechanisms type NP8, 00 pole distance 00 mm. Equipment Indoor disconnectors type OWD may be equipped with manual, motor, or pneumatic operating mechanism and an auxiliary switch. Manual and motor driven operating mechanisms do not form an integral part of the disconnector and are supplied to separate orders. The type of operating mechanism applied depends on the type of disconnector, in accordance with table (the table does not account for pneumatic operating mechanisms). Table Type of disconnector OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 Type of operating mechanism HE, NRWO-, UEMC0 A_ or isolating rod HE, NRWO- UEMC0 A_ UEMC0 K_. Design and operation One, two and three pole disconnectors type OWD are the vertical break disconnectors. The base is a steel frame to which the operating mechanism is fixed. Bracketing insulators are fastened to the frame and are the mounting for the current circuit which consists of two fixed contacts and one moving contact on each pole. The moving contacts are connected to the shaft by means of insulating pull-rods. Pressing the moving contact to the fixed contact is solved in such a way that, at shorting currents, due to the effect of magnetic action upon the cover plate, the pressure increases. This allowed to obtain high rated values of peak current and shorting heat current. Two contact rails may be fixed to each terminal clamp A mechanism type NP8 is used as pneumatic operating mechanism, with rated pressure 0,, MPa, one or two drives are used, depending on the rated pressure and model of the disconnector in accordance with the table. If a disconnector is ordered with pneumatic operating mechanism or motor UEMC0K, it is coupled with the mechanism by the manufacturer and is an inseparable part of the complete supply. Indoor disconnectors OWD and OWIII

6 Table Type of disconnector OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 OWD0w.0, OWD0w.0 Type of operating mechanism NP8 Number of drives 0, MPa 0,8 MPa An auxiliary switch type PS- or PS O can also be supplied (to a separate order). It is meant to be mounted in the chamber and connected by a rod with the lever on the disconnector shaft. The standard length of the connecting rod is 00 mm.. Technical data Technical data of the disconnectors are tabulated in table on page.. Standards Disconnectors type OWD comply with the standards: IEC 7-:007, IEC 7-0: Spare parts The apparatus, for the duration of its technical lifetime, i.e. 000 operations, does not require spare parts. On the user s request, spare parts may be supplied for those damaged during random events, however, their replacement should be consulted with the manufacturer each time, and made by ABB service or by employees of other companies who have been trained by the manufacturer. 8. Information to be given with orders The following information should be given with order: product full name, rated voltage, rated current and type of the apparatus. Operating mechanisms for the disconnectors should be ordered separately. When ordering a disconnector with pneumatic operating mechanism, please specify on which side of the disconnector it is to be mounted. 9. Examples of orders. Two pole indoor disconnector for rated voltage, kv, rated current 000 A, with pneumatic operating mechanism on the left hand side, equipped with auxiliary switch type PS-: Two pole indoor disconnector, type OWD 0w.0/,, kv, 000 A, with operating mechanism NP8 on the left, with auxiliary switch type PS-.. Three pole indoor disconnector for rated voltage kv, rated current 00 A, with two pneumatic operating mechanisms (for pressure 0, MPa), with auxiliary switch PS-: Three pole indoor disconnector, type OWD 0w.0/, with auxiliary switch type PS-, kv, 00 A, with two operating mechanisms NP8. 0. Attachments Dimension drawings: OW/07.0 OW/08.0 OW/09.0 OW/0.0 OW/.0 Indoor disconnectors OWD and OWIII

7 Table. Technical data of disconnectors type OWD Item Specification Unit OWD 0w.0 OWD 0w.0 OWD 0w.0 OWD 0w.0 OWD 0w.0/00 OWD 0w.0 OWD 0w.0 OWD 0w.0 OWD 0w.0 OWD 0w.0 OWD 0w.0 Rated voltage [kv],, Righted power frequency withstand to earth and between poles, 0 0 [kv] voltage between contacts, 0 Lightning impulse withstand voltage to earth and between poles [kv] between contacts - 8 Rated continuous current standard model N [A] tropical model T Rated short-time withstand current -s [ka] s Rated peak withstand current Frequency [Hz] 0 0 Rated pressure of pneumatic operating mechanism [MPa] 0,, for manual and motor drive operating mechanism [kg] Disconnector mass with one pneumatic operating mechanism with two pneumatic operating mechanisms Minimum isolating gap between contacts [mm] Maximum distance of first bracket at rated peak current [mm] Indoor disconnectors OWD and OWIII 7

8 Dimensional drawings Indoor disconnectors type OWD, kv for motor drive UEMC0A_ and manual drive HE Dimensions of the disconnector for a operating mechanism at the left side are determined on the principle of mirror image. OWD 0w.0/ OWD 0w.0, 0, 0 00, 000, OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w Type Un [kv] I n [A] A B C D E F G H I J K L M N P R dimension Drawing No. OW/07.0 shaft extension for auxiliary switch terminals: material: copper coating: silver Earthing clamp material: steel coating: tin 8 Indoor disconnectors OWD and OWIII

9 Dimensional drawings Indoor disconnectors type OWD, kv for pneumatic operating mechanism OWD 0w.0, 0, 0 00, 000, OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w OWD 0w.0, OWD 0w.0, OWD 0w.0, 0, 0 00, 000, OWD 0w Type Un [kv] I n [A] A B C D E F G H I J K L M N P R S T dimension shaft extension for auxiliary switch Drawing No. OW/08.0 terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Indoor disconnectors OWD and OWIII 9

10 Dimensional drawings Indoor disconnectors type OWD, kv with two pneumatic operating mechanisms OWD 0w.0 /00/ OWD 0w.0, 0, 0/ 00, 000, OWD 0w.0, 0, 0/ 00, 000, OWD 0w.0/ OWD 0w.0/ OWD 0w.0/, OWD 0w.0/, Type Un [kv] I n [A] A B C D E F G H I J K L M N P R S dimension Drawing No. OW/09.0 terminals material: copper coating: silver Earthing clamp material: steel coating: tin 0 Indoor disconnectors OWD and OWIII

11 Dimensional drawings Indoor disconnectors type OWD, kv OWD 0w.0/, OWD 0w.0/, Type Un [kv] I n [A] A B C D E F G H I J K L M N P dimension Auxiliary contact Drawing No. OW/0.0 terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Indoor disconnectors OWD and OWIII

12 Dimensional drawings Indoor disconnectors type OWD, kv for manual operating mechanism type NRWO- Drawing No. OW/.0 shaft extension for auxiliary switch Type Un [kv] I n [A] dimension A B C D E F G H I J K L M N P R OWD 0w.0/ OWD 0w.0, 0, 0/ 00, 000, OWD 0w.0/, OWD 0w.0/, OWD 0w.0/ OWD 0w.0, 0, 0/ 00, 000, OWD 0w.0/, OWD 0w.0/, OWD 0w.0/ OWD 0w.0, 0, 0/ 00, 000, OWD 0w.0/, OWD 0w.0/, OWD 0w.0, 0, 0/ 00, 000, Dimensions of the disconnector for a operating mechanism at the left side are determined on the principle of mirror image. terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Indoor disconnectors OWD and OWIII

13 Three-pole indoor disconnectors type OWIII. Operating conditions The disconnectors are meant for operation indoors, in temperate climate conditions, at surrounding temperatures ranging from C to +0 C. When installing the switches in other conditions, it is necessary to consult the manufacturer.. Designations and switch types OWIII 0 / UD - /0 Type of disconnector Rated voltage 7, 7, kv 0 kv 7, 7, kv 0 kv 0 kv Rated current 0 A A A 0 A 00 A Type of earthing switch UD lower earthing switch UG upper earthing switch Type of insulator ceramic resin Pole distance Specified only for pole distances other than typical: kv 00 mm kv 7 mm kv 0 mm. Design and operation Disconnectors type OWII are the vertical break disconnectors. The disconnectors base is made as a welded steel frame. The frame together with the disconnector shaft and the limiters of the angle of rotation forms a non-dismountable unit. The base carries the insulators which support the main circuit consisting of two fixed contats and one moving contact in each pole. The moving contacts are connected with the disconnector shaft by means of insulating pull rods which transfer the rotation of the shaft to the moving contacts bringing them in sweep motion in the plane perpendicular to the disconnector base. The intrepole isolation is an air gap. In models with a smaller interpole scale, the air gap is further assisted by isolating plates. The disconnectors may be opened and closed by the following operating mechanisms: manual: type NRWO/... or HE, pneumatic, type NP9, motor, type UEMC0A_, insulating stick. The disconnectors, equipped with manual, motor or pneumatic operating mechanism, may operate in horizontal or vertical position (driven by insulating stick only in vertical position). The construction of disconnectors allows for the addition of earthing switches. Earthing switches may be located on pivot side (lower earthing switches) or on opening (upper earthing switches). At the base of the disconnector there is an earth terminal with Mx0 screw. Between the disconnector shaft and the earthing switch shaft, there is a mechanical interlocking ensuring the proper order of switching.. Equipment Disconnectors type OWIII are equipped with an operating lever set on the shaft, which can be moved every 0 within the limits of a full turn. This lever is for coupling with operating mechanism type NRWO/... and with a lever arm which is an extension of the operating lever, meant for driving the disconnector by means of an insulating stick. In the case of disconnectors with motor operating mechanism UEMC0A_ there is no lever. Instead, there is an assembly of bevel gear linking with the operating mechanism. The disconnectors may be equipped with an auxiliary switch (type PS- or PS-O) coupled with the apparatus, located on the end of the shaft opposite to the operating mechanism. Standard number of auxiliary switch contacts is (NO+NC).. Technical data The technical data of disconnectors are tabulated in the table on pages -.. Standards Disconnectors type OWII comply with the standards: IEC 7-:007, IEC 7-0: Spare parts The apparatus, for the duration of its technical lifetime, i.e. 000 operations, does not require spare parts. On the user s request, spare parts may be supplied for those damaged during random events, however, their replacement should be consulted with the manufacturer each time, and made by ABB service or by employees of other companies who have been trained by the manufacturer. 8. Information to be given with orders The following information should be given with order: product full name, rated voltage, rated current and type of the apparatus. Operating mechanisms for the disconnectors should be ordered separately. 9. Examples of orders. A disconnector for rated voltage kv, rated current 0 A, equipped with lower earthing, with ceramic insulators: Three pole indoor disconnector, kv, 0A with lower earthing switch, type OWIII 0/UD.. A disconnector for rated voltage kv, rated current 0 A, equipped with upper earthing switch, with resin insulators, with pneumatic operating mechanism type NP9 assembled on the left hand side: Three pole indoor disconnector, kv, 0 A with upper earthing switch, type OWIII 0/UG + NP9 on the left. 0. Dimensional drawings OW/0.0, OW/.0, OW/.0, OW/.0, OW/.0. Indoor disconnectors OWD and OWIII

14 Table. Technical data of disconnectors type OWIII Disconnectors for voltage 7, and kv Type OWIII7,/- OWIII7,/UD- OWIII7,/UG- OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/-/ OWIII0/UD-/ OWIII0/UG-/ OWIII0/8- OWIII0/8UD- OWIII0/8UG- OWIII0/0- OWIII0/0UD- OWIII0/0UG- OWIII0/8- OWIII0/8UD- OWIII0/8UG- OWIII0/0- OWIII0/0UD- OWIII0/0UG- OWIII0/- OWIII0/UD- OWIII0/UG- Rated voltage [kv] 7, Frequency [Hz] 0 to earth and 0 8 Righted power frequency withstand voltage [kv] between poles between contacts Lightning impulse withstand voltage [kv] to earth and between poles 0 7 between contacts 70 8 Rated continuous current [A] Rated peak withstand current [ka] Rated short-time withstand current [ka] s,,,, Disconnector mass / mass disconnector / /9 / / /9 /9 / / 0/9 with earthing switch [kg] Maximum distance of first bracket at rated peak current [mm] Disconnectors for voltage 7, and kv Type OWIII7,/- OWIII7,/UD- OWIII7,/UG- OWIII7,/- OWIII7,/UD- OWIII7,/UG- OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/-/0 OWIII0/UD-/0 OWIII0/UG-/0 OWIII0/8- OWIII0/8UD- OWIII0/8UG- Rated voltage [kv] 7, Frequency [Hz] 0 Righted power frequency withstand voltage [kv] Lightning impulse withstand voltage [kv] to earth and between poles 8 0 between contacts 0 to earth and between poles 9 between contacts 0 OWIII0/0- OWIII0/0UD- OWIII0/0UG- OWIII0/8- OWIII0/8UD- OWIII0/8UG- OWIII 0/0- OWIII0/0UD- OWIII0/0UG- OWIII0/- OWIII0/UD- OWIII0/UG- Rated continuous current [A] Rated peak withstand current [ka] Rated short-time withstand s - - -, current [ka] s Disconnector mass / mass disconnector with earthing switch [kg] / 8/78 8/8 9/9 8/7 8/8 8/8 9/9 70/8 Maximum distance of first bracket at rated peak current [mm] Indoor disconnectors OWD and OWIII

15 Disconnectors for voltage kv Type OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/- OWIII0/UD- OWIII0/UG- OWIII0/- OWIII0/UD- OWIII0/UG- Rated voltage [kv] Frequency [Hz] 0 Righted power frequency withstand voltage [kv] to earth and between poles 70 between contacts 80 to earth and between poles 70 Lightning impulse withstand voltage [kv] between contacts 9 Rated continuous current [A] Rated peak withstand current [ka] Rated short-time withstand s -,, current [ka] s Disconnector mass / mass disconnector with earthing switch [kg] 78/90 90/0 90/0 Maximum distance of first bracket at rated peak current [mm] 000 Indoor disconnectors OWD and OWIII

16 Dimensional drawings Indoor disconnectors type OWIII Drawing No. OW/0.0 Terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Dimension Type A A A A A A B B B C C C C C OWIII 7,/ OWIII0/,8, OWIII 0/,8, OWIII 0/-/ OWIII 0/ OWIII 7,/ OWIII 7,/ OWIII 0/,8, OWIII 0/,8, OWIII 0/-/ OWIII 0/ OWIII 0/ OWIII 0/ OWIII 0/ Indoor disconnectors OWD and OWIII

17 Dimensional drawings Indoor disconnectors type OWIII with lower earthing switch Drawing No. OW/.0 Terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Dimension Type A A A A A A A7 B B B C C C C C OWIII 7,/UD OWIII0/,8,0UD OWIII 0/,8,0UD OWIII 0/UD-/ OWIII 0/UD OWIII 7,/UD OWIII 7,/UD OWIII 0/,8,0UD OWIII 0/,8,0UD OWIII 0/UD-/ OWIII 0/UD OWIII 0/UD OWIII 0/UD OWIII 0/UD Indoor disconnectors OWD and OWIII 7

18 Dimensional drawings Indoor disconnectors type OWIII with upper earthing switch Drawing No. OW/.0 Terminals: material: copper coating: silver Earthing clamp material: steel coating: tin Dimension Type A A A A A A A7 B B B C C C C C OWIII 7,/UG OWIII 0/,8,0UG OWIII 0/,8,0UG OWIII 0/UG OWIII 7,/UG OWIII 7,/UG OWIII 0/,8,0UG OWIII 0/,8,0UG OWIII 0/UG-/ OWIII 0/UG OWIII 0/UG OWIII 0/UG OWIII 0/UG Indoor disconnectors OWD and OWIII

19 Dimensional drawings Indoor disconnector type OWIII with pneumatic operating mechanism Dimensional drawings Indoor disconnector type OWIII with auxiliary switch Drawing No. OW/.0 Drawing No. OW/.0 A7 Dimension Type A7 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 0 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 0 OWIII 0/-/ 0 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 8 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 9 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 9 OWIII 0/-/0 OWIII 0/UD-/0 OWIII 0/UG-/0 9 OWIII 0/- OWIII 0/UD- OWIII 0/UG- 7 OWIII 0/- OWIII 0/UD- OWIII 0/UG- OWIII 0/- OWIII 0/UD- OWIII 0/UG- OWIII 0/- OWIII 0/UD- OWIII 0/UG- max. 00 Indoor disconnectors OWD and OWIII 9

20 Manual Operating Mechanism Indoor type NRWO-. Application NRWO operating mechanisms are used for closing and opening disconnectors and earthing switches (attached to indoor disconnectors) for voltages up to kv.. Operating conditions NRWO... operating mechanisms may be installed in indoor distribution devices.. Description of types NRWO... operating mechanisms may be installed in indoor distribution devices. NRWO L /NO (0) /PS- () Marking of the NRWO group operating mechanisms L connection rod on the left side of the operating mechanism P connection rod on the right side of the operating mechanism NO NO electromagnetic locking device (voltage current) BM mechanical locking device. PS- PS- auxiliary switch additional information on number of contacts is given in parentheses (; 0; 8; ) PSO PSO auxiliary switch additional information on number of contacts (; 0; 8; ). Construction and operating principle The NRW0... manual operating mechanism is a four-bar linkage with cranks and rocking levers. It contains a hand lever, arched pull rod, a double lever welded to the shaft terminated on one side with multinotches and two side plates, between which the entire kinematic configuration is located. Operation is possible by appropriate use of the four-bar linkage properties, which by setting the crank causes the rocking lever and the attached connecting lever to rotate. Rotation of this lever is transferred, by means of the pull rod, to the lever on the disconnector shaft. The hand lever has a knob at the top. The two side plates contain a sleeve for assembling the locking device. Fenders are also welded in order to limit deviation of the hand lever. The auxiliary switch is located on the bracket fixed to the upper edges of the side plates and is connected to the drive shaft by means of a special mechanism, which shifts the moving contacts in the final stages of shaft movement.. Equipment a pull rod for linking the operating mechanism with the disconnector 000 mm long (standard equipment) mechanical locking device (optional) NO electromagnetic locking device (optional) rated voltage /0/0 V DC PS- or PS-O auxiliary switch (optional), number of contacts:, 0, 8,. Technical data a) Angle of shaft rotation b) Length of operating mechanism hand lever 0 mm c) Angle of hand lever rotation 70 d) Weight ca 8 kg 7. Standards NRWO... operating mechanisms comply with the standard IEC 9 (98). 8. Remarks on spare parts The operating mechanism does not contain any sub-assemblies, parts or items, which are subject to replacement as a result of use. At the user s request, accessories damaged in the event of unforeseen circumstances may be supplied. However, their replacements must be agreed with the manufacturer each time. 9. Information to be given with orders The following information should be given with order: product full name, type of operating mechanism, type of equipment as in p.. 0. Example of an order manual operating mechanism NRWO- L/NO (0)/PSO (0). The above is an example of an order for a manual operating mechanism indoor NRWO- with connection rod on the left side, equipped with an electromagnetic NO locking device for voltage 0 V DC and PSO auxiliary contact with 0 contacts. 0 Indoor disconnectors OWD and OWIII

21 70 Dimensional drawing Manual operating mechanisms type NRWO- A B Type NRW0-.../.../PSO() NRW0-.../.../PSO(0) NRW0-.../.../PSO(8) NRW0-.../.../PSO() NRW0-.../.../NO NRW0-.../BM/... NRW0-.../BE/... NRW0-.../NO/... 0 B NRW0--P... R90 R7 NRW0--L... Locking device may be installed on the reverse side of the operating mechanism. 90 W : max 000 Mx-.8 W 8 Ø.9 xø0. 0 ± Location of assembly 0 9 A 0 0 Indoor disconnectors OWD and OWIII

22 Motor operating device type UEMC0_. General The UEMC 0 A_, and UEMC 0 B_ motor operating devices are intended for indoor mounting on medium voltage disconnectors and earthing switches. Operation can be performed both electrically or by means of the manual operating lever. Operating time is about...8 s depending on the type of device and loading conditions.. Standards The motor operating device complies with IEC (98) VDE 00 motor voltage test Rys Power unit. Limit switch. Guide pin. Coupling ring. Locking catch. Motor 7. Terminal block 8. Control push button 9. M.c.b. 0. Contactor. Lever. Nut. Construction Power is transfered from the motor through a gear wheel and threaded shaft to the operating axel. The direction of operation for open and close control can be reversed by changing the motor s direction of rotation. The threaded shaft gear is assembled from a round stainless steel shaft and one or two bronze nuts. The shaft is selflocking which means that the operating device cannot be rotated with a force from the operating axel. This also applies if the operating device is in the central position. The nuts transfer the power through the specially formed lever to the operating axel. The lever is formed so that it can be locked in the extream position. By disengaging the coupling ring, manual operation can be performed by means of the control lever. Both the gear wheel and the threaded shaft are greased with low temperature grease which ensures correct operation in temperatures as low as 0 C... Mechanical locking The unit is fitted with a locking device which also includes a switch to prevent the motor from operating. The locking unit mechanically locks the operating device and is strong enough to withstand the driving force of the motor if the blocking switch S fails. The locking unit locks both the motor operating device and the manual operating device.. Electrical operation Motor operating device type UEMC 0 A_, B_ are fitted with a lower level of electrical components, and require a separate control unit, such as UEZJ or UEZJ. Refer to circuit diagram: UEMC 79. Motor operating device type UEMC 0 A_, B_ are equipped with a complete control system including contactors, I- and O- push buttons and m.c.b. Refer to circuit diagram: UEMC 8. Indoor disconnectors OWD and OWIII

23 . Technical details Operating time at standard load: to 8 s Direction of operation: clockwise to close easily changeable Motor: Rectified DC, permanent magnet type Terminal block mm 7. Equpment Operating handle YMX0M000 The operating handle is insulated and fitted with an insulated grip. Rated voltage Normal control current*) Max. current**) Recommended M.c.b. V DC A 0 A STO S7 K8 8 V DC A 0 A STO S7K 0 V DC A 7 A STO S7 K 0 V DC A, A STO S7 k V DC A, A STO S7 K 0 V DC A A STO S8 UCK 0 V AC A A STO S7 K * Rated current is the current under normal working conditions. ** Max. current is the current for a stalled load from the motor operating device. Secification Unit UEMC 0 UEMC 0 A A B B Torque: [Nm] Weight: [kg],,,, Contactors: Closing power: [W] Holding power: [W] Shortest control pulse [s] 0, 0, 0, 0, Operating angle: degr degr. 0 ) 0 ) - - Extension shaft UEMC ZL Includes: shaft 0 mm (splined) extention socket 70 mm (splines to splines) The shaft have cutting grooves at regular intervals. ø splined / ø splined ø splined 0 max Coupling ring UEMZ Increases the operating angle to 0 for motor operating devices UEMC 0 A_ 70 ) With accessory: Coupling ring UEMZ Indoor disconnectors OWD and OWIII

24 Protective m.c.b. Used to connect the supply circuit and protect the motor against overloading. Motor voltage Miniature circuit breaker type V DC - STO S7 K8 8 V DC - STO S7 K 0 V DC - STO S7 K 0 V DC - STO S7 K V DC - STO S7 K 0 V AC - STO S7 K 0 V DC - STO S8 UCK 0 V AC - STO S7 K Pk Pg Pr 8, ø, 0 0 ON Auxiliary contact for m.c.b. - STO S -S/H Includes pcs. change-over contacts Control unit UEZJ - Typ Circuit diagram UEZJ - V DC UEMC UEZJ - 8 V DC UEMC UEZJ - 0 V DC UEMC UEZJ - 0 V DC UEMC UEZJ - V DC UEMC UEZJ - 0 V DC UEMC UEZJ - 0 V AC UEMC UEZJ - 0 V AC UEMC UEZJ - UU ) UEMC ) Set type UEZJ UU is to be ordered when different motor and auxiliary voltages are to be used. Please give details of the voltages when ordering. I > Operating box UEZJ - Type Circuit diagram UEZJ - V DC UEMC 8 UEZJ - 8 V DC UEMC 8 UEZJ - 0 V DC UEMC 8 UEZJ - 0 V DC UEMC 8 UEZJ - V DC UEMC 8 UEZJ - 0 V DC UEMC 8 UEZJ - 0 V AC UEMC 8 UEZJ - 0 V AC UEMC 8 UEZJ - UU ) UEMC 9 ) Type UEZJ -UU is to be ordered when different motor and auxiliary voltages are to be used. Please give details of the voltages when ordering. V K K 8 Indoor disconnectors OWD and OWIII

25 Control push buttons UEZJ Includes: I -button, with text: (CLOSE) O -button, with text: OPEN On/Off selector switch, with text: REMOTE ON/OFF Adjuster coupling UEMC ZL0 Provides facility to adjust the extreme positions exactly and to reduce control angle steplessly max 0. Rmax 0 OPEN CLOSED REMOTE ON/OFF 0 Adjuster coupling UEMC ZL9 Provides facility to adjust the extreme positions exactly and to reduce control angle steplessly max 0. ø splined splined ø Rmax 0 ø splined ø splined 0 ø splined ø, Joint UEMC ZL7 For transmitting the operating movement through an angle of max 0. For tube diameter: / (.9 mm) 0 7 ø splined ø splined ø 7, ø splined Indoor disconnectors OWD and OWIII

26 8. Dimension drawing UEMC 08 D 0 0 A Pk Pg Pr, Only with types UMEC 0 UMEC 0 A B B 0 ø splined ø...9 V C x M0 Type A B C V M UEMC 0 mm mm mm Degr. Nm 0 A ) 00 A ) 00 B B ) Accessories, to be ordered separately. Front panel drilling Indoor disconnectors OWD and OWIII

27 9. Exampes of applications for disconnectors UEMC0A_ with disconnector OWIII/ OWD connection through an angle of max. 0º I O 7 max Disconnector type OWIII...(OWD) Motor operating device UEMC0A_ Joint UEMC ZL7 Operating handle YMX0M000 Extension shaft:ymr8m000(optionally for OWIII) or YMR7M000 for OWD kv, YMR7M000 for OWD kv Bevel gear NRK* 7 Connection rod (L=, m) YMX00000M000 8 Adjuster coupling UEMC ZL0 9 Auxiliary switch complete OW E0... (option) * NRK/ in case use of extension shaft (pos.); NRK / if directly on the OWIII shaft. If there is no possibility connection through an angle of max. 0º it should be with angle 90º as below: UEMC0A_ with disconnector OWIII/ OWD connection through an angle of 90º 0 Disconnector type OWIII... (OWD) Motor operating device UEMC0A_ Bevel gear NRK* Operating handle YMX0M000 Adjuster coupling UEMC ZL0 Rod joint compl. YMX0000M000 7 Bevel gear YMX0M000 8 Bevel gear support YMR7707M000 (for OWIII) or YMX0M000 (for OWD) 9 Connection rod (L=, m) YMX00000M000 0 Connection rod (L= m) YMX00000M * NRK/ in case use of extension shaft (pos.); NRK / if directly on the OWIII shaft. 9 Indoor disconnectors OWD and OWIII 7

28 Example of connection UEMC0B with disconnector OWIII0/- I O Disconnector type OWIII0/- Motor operating device UEMC0B_ Adjuster coupling UEMC ZL0 Operating handle YMX0M000 Extension shaft: YMR8M Spare parts When ordering spare parts all details on the rating plate are to be mentioned. Spare part Type Remarks Motor + gear wheel UEZM /U*/ U = Voltage Motor gear wheel J0 Diode SK/ Rectifier RECBR0 Limit switch: S, S OYAX Contactor: K, K ABBBC 0 0/U U = Voltage Relay: K RFI Circuit diagrams UEMC 79 C UEMC0A, B X: 9 (L) (N) 0 red black M S S S R* For types : UEMC 0 A -, 8, 0, 0,, 0 V DC UEMC 0 B -, 8, 0, 0,, 0 V DC M Motor S, S Limit switches S Blocking switch for locking * R Heater (to be ordered separately) 8 Indoor disconnectors OWD and OWIII

29 UEMC 8 L UEMC0A, B (L/+) (L/+) I 7 Brązowy brown O Czerwony red 8 9 F V - + V S I S O X: V K K F Czerwony red Czarny black (N/-) M - - K K K R A A V K S K S 0 (N/-) A A K S K A A K K V S R* For types : UEMC 0 A -, 8, 0, 0,, 0 V DC; 0, 0 V AC; UU**) UEMC 0 B -, 8, 0, 0,, 0 V DC; 0, 0 V AC; UU**) F M.c.b. S Push buttons (I and O) M Motor K, K Operating contactors K Relay for 8 0 V S, S Limit switches S Blocking switch, locking V Rectifier for AC V-V Diodes for DC R Resistor for 0 0 V *) R Heater (to be ordered separately) **) Detail motor and aux. voltage Indoor disconnectors OWD and OWIII 9

30 Control unit UEZJ _ UEMC E For types: UEZJ -, 8, 0, 0,, 0 V DC; 0, 0 V AC; *) -0 VAC -0 VAC (L) (+) X: V - + R K 7 8 K K K K K A K A K K K, K Operating contactors K Relay for 8-0 V V, V Diodes V Rectifier only for AC R Resistor for 0-0 V K K V A A K K V A A V X: - - (N) ( ) 7 UEMC D For types: UEZJ _UU Note: DC contactors (L) (+) (L) (+) X: V - + R V - + K K A K A K K K V 7 K K K A A 8 K A A K K, K Operating contactors K Relay for 8-0 V V, V Diodes V, V Rectifier only for AC R Resistor for 0-0 V V V - - V - - X: 7 (N) (-) (N) (-) 0 Indoor disconnectors OWD and OWIII

31 Operating box UEZJ _ UEMC 8 D X: V - + V (* X: -0 VAC -0 VAC (L) - - R (+) K K K A A K S K For types: UEZJ -, 8, 0, 0,, 0 V DC; 0, 0 V AC; S I 7 8 S O K V K K A A K H I Czerw. K A A 9 x x K 7 H O Ziel. V 0 x x H9 Żłt. x x 0 K, K Operating contactors S, S Push buttons S Remote control selector K Relay for 8-0 V R Resistor for 0-0 V V, V Diodes V Rectifier only for AC H Position indicator, closed, red H Position indicator, open, green H9 Indicator for fuse tripping,yellow (N) (-) UEMC 9 E X: V V X: (L) - (* R (+) K K V (L) - K (* + K A A K (+) S For types: UEZJ _UU V S I K V S O K K 8 K A A H I Red K A A 9 x x K 7 H O Gr V 0 x x H9 Yw x x 0 K, K Operating contactors S, S Push buttons S Remote control selector K Relay for 8-0 V R Resistor for 0-0 V V, V Diodes V, V Rectifier only for AC H Position indicator, closed, red H Position indicator, open, green H9 Indicator for fuse tripping, yellow (N) (-) (N) (-) Indoor disconnectors OWD and OWIII

32 Example of connection for UEMC 0_... + UEZJ UEMC D O Alt A I Clockwise closed Alarm (+) F S X: K K A R K A S I K 7 K K S O K 8 K K F M.c.b. S,S Push buttons S Remote control selector S7 Aux. contact for disconnector S8 Aux. contact for earthing switch S9 Aux. contact for fuse tripping H Position indicator, closed, red H Position indicator, open, green H9 Indicator for fuse tripping,yellow K K V K A A A A K V UEMC 0 A, B- UEZJ - X: (-) F X: Czerwony M Czarny S 9 0 S9 S S8 S S 7 R (* (L) (N) Indoor disconnectors OWD and OWIII

33 Example of connection for UEMC 0_... + UEZJ UEMC C Alt B Anti-clockwise closed I O (+) Alarm S7 S9 (+) F S S I O H I Czerw. x x H O Ziel. x x H9 Żółty x x X: S S I S O H I Czerw. x x H O Ziel. x x H9 Żółty x x R K K K K A A K K V K K K A A K K K A A K V UEZJ - X: 7 0 F S9 S8 (-) (-) (L) (N) UEMC 0 A, B, D- X: Czerwony M Czarny S 9 0 S S S R (* F M.c.b. S,S Push buttons S7 Aux. cont. for disconnector S8 Aux. cont. for earthing switch S9 H H H9 Aux. cont. for fuse tripping Pos. indicator, closed, red Pos. indicator, open, green Ind. for fuse tripping, yellow Indoor disconnectors OWD and OWIII

34 NO type electromagnetic interlock. Features effective interlocking a disconnector control devices in off-voltage state, easy operation, easymounting on disconnector control unit, reliable, metal structure, metal parts protected by electroplating or made of stainless steel.. Applications The NO type electromagnetic interlock for indoor use is designed to interlock NRWO disconnector control devices in open or closed state, enabling a correct operating of such control devices in control and interlocking system of indoor switchgears. The NO type interlock, without voltage supply is always locked and its design makes it impossible to take lock back from control lever in a mechanical way without energizing the electromagnet coil.. Versions N0 0 Interlock type Rated voltage 0 V DC 7 V DC V DC 0 V DC 0 V DC 8 V DC V DC. Design and operation The NO type electromagnetic interlock consists of two main components.the mechanical part is made of a body closedwith cover. The spring-operated lock is placed in the body.the lock hole ends with nut, whereas the pull rod ends with ring handle. Pusher controlling a micro-switch, which switches in turn voltage fromterminals to the coil, is located in the upper part of the body.the micro-switch with terminals is placed under protective cover. The electromagnetic part consists of a plunger tightenedwith spring. Electromagnet coil is located in a housing fastened to the base. The base with bearing is mounted in the lower part of the interlock body. In case of the NRWO type apparatus interlock is fixed by means of two Mx0 screws. As a result of the interlock s mounting on the disconnector control, the lock is plunged in the hole of control lever, thus disabling its rotation, which in turn makes it impossible to operate the disconnector control device. As a result of pulling the ring handle with hand the pull rod moves along the lock axis, pushing the pusher upwards. The action in question switches the micro-switch and supplies at the same time the electromagnet coil. The coil magnetic field draws the plunger out from the lock. Further pulling of ring handle causes that the pull rod pulls the lock with it, which -in turn- drawing out from the disconnector control lever holemakes it possible to operate the disconnector control (pushing the lever in the limit positions, i.e. to closed and open positions). Leaving the control lever in intermediate position and releasing the interlock ring holder makes the electromagnet operate continuously till the control lever is pushed to limit position. After pushing control lever in position open or closed and after releasing Indoor disconnectors OWD and OWIII

35 the interlock ring holder all springs of interlock mechanism make interlock return automatically to the original state. The interlock design disables to operate disconnector control devices in the absence of interlock supply voltage coming from control and interlocking system of a switchgear, thus when the operation of disconnector control device is forbidden.. Technical data See table.. Standards The NO type electromagnetic interlock meets the requirements of the following standards: IEC 9 (98). 7. Placing orders The order must comprise: product full name type designation rated voltage quantity ordered All additional requirements not taken into account in this document must be agreed with manufacturer in form of an inquiry made in writing with the information about the of the requirements (regulations, standards, etc.). 8. Example order NO-0 type electromagnetic interlock, rated voltage 0 V DC 0 pcs. TABLE. Technical data of electromagnetic interlocks. Parameter Units Type NO-0 NO-7 NO- NO-0 NO-0 NO-8 NO- Coil rated voltage [V DC] Power consumption [W] Coil test voltage AC [kv] Micro-switch test voltage AC [kv] Lock operating travel Ø mm [mm] Pull rod travel to coupling with lock [mm] Weight [kg] Overall dimensions. 0 x Mx0 Ø Electromagnetic Interlock Type NO-0 U n -0V DC ;P-W Ø 88 Circuit diagram Indoor disconnectors OWD and OWIII

36 Contact us: ABB Sp. z o.o. Branch in Przasnysz 9 Leszno Str Przasnysz, Poland marketingmv@pl.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Sp. z o.o. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB Sp. z o.o. 0PL7-W-pl. Edition 0.0 Copyright 0 ABB All rights reserved

Motor Operating Device NAL/NALF

Motor Operating Device NAL/NALF Motor Operating Device NAL/NALF UEMC 40 K3_ Installation-, operating- and recycling guide ABB Power Distribution 1 Motor Operating Device Contents 1. General... 3 2. Standards... 3 3. Transport and storage...

More information

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

CATALOGUE. ON Medium Voltage Outdoor Disconnectors CATALOGUE ON Medium Voltage Outdoor Disconnectors 2 O N M E D I U M V O LTA G E O U T D O O R D I S C O N N E C TO R S ON MEDIUM VOLTAGE OUTDOOR DISCONNECTORS 3 Table of conteants 004 1. Introduction 004

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

Selective main circuit breakers S 750 series Technical Data

Selective main circuit breakers S 750 series Technical Data Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.

More information

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 2 Semi-pantograph

More information

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Product Brochure Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Introduction General The braking switch serves the purpose of electrical braking a machine in a hydro or pumped

More information

NPS modular outdoor switch-disconnectors

NPS modular outdoor switch-disconnectors NPS modular outdoor switch-disconnectors 2 NPS Index Introduction... 4 Technology review... 5 NPS technology... 5 Product review... 9 Benefits... 9 Technical data... 10 Samples of pole installation...

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker

More information

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance MEDIUM VOLTAGE PRODUCT KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2

More information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT. PowerIT PowerIT Indoor Voltage Transformer Fuses, WBP Outdoor Voltage Transformer Fuses, BRT Catalogue 1YMB612070-en Industrial IT enabled TM 1. FEATURES Unlimited breaking capacity Short circuit current

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

S&S POWER SWITCHGEAR EQUIPMENT LTD.,

S&S POWER SWITCHGEAR EQUIPMENT LTD., S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

Typical installations of the NPS modular outdoor switch disconnector

Typical installations of the NPS modular outdoor switch disconnector Typical installations of the NPS modular outdoor switch disconnector 2 NPS Index 1. Introduction...4 2. Technology...5 Modularity...5 Relays and controlers...9 3. Product review...11 Benefits...11 Technical

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance MEDIUM VOLTAGE PRODUCT KECA 250 B1 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C184; KECA 80 C216 CURRENT SENSORS INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Surge arrester POLIM-C.. HD

Surge arrester POLIM-C.. HD DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10

More information

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp) Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance MEDIUM VOLTAGE PRODUCT KECA 80 D85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 D85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2

More information

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A Outdoor load disconnectors three-pole design rated voltage 25 and 38.5 kv rated current 630 A outdoor load disconnectors The breaking operation at the load disconnectors uses the energy of spring-based

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9 Content 1. Design philosophy... 3 2. Applications... 5 3. Switchgear construction... 6 4. Cubicle types... 9 4.1 Cubicle program... 9 4.2 Cubicle type SDC... 11 4.3 Cubicle with fuse, type SDF...12 4.4

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp) Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring ABB is a leader in power and automation technologies that enable utility and industry customers to

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples. Transportation and storage.. 3 General. 3 Unpacking at installation site....... 3 Transfer of cubicles at installation site... 3 Weight.. 4 Temporary storage. 4 Erection at site 5 General. 5 The switchgear

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A Outdoor disconnectors FTr (previously 6 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current and 6 A 1 Outdoor disconnectors Outdoor disconnectors, produced in accordance

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network PRODUCT BROCHURE Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet)

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

ZX2 Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive Vacuum Circuit-Breakers, Type HVX 12 24 kv, of cassette design, cassette with motor drive Operating Instructions No. 531 321, Edition 09/00 Table of Contents 1 General 4 1.1 Operating Conditions 4 2 Design,

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

COMPONENTS. Off-load Switch for Fixed Installation Title type SW COMPONENTS Off-load Switch for Fixed Installation Title type SW General information The SW off-load switch is a complete range designed to cover all the applications to be met in DC traction power substations

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A. ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS OVERVIEW has always been concerned with keeping a service policy for its products by means of a wide range of DRIWISA spare parts', original parts' and

More information

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH Peters& Thieding Hochspannungstechnik GmbH Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH OVERVIEW The PTE earthing switch is an indoor switching device for installation in air-insulated

More information

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

EAS822 (Contrac) Power Electronic Unit

EAS822 (Contrac) Power Electronic Unit Contents Data Sheet Rev. A EAS822 (Contrac) Power Electronic Unit For continuous control of Contrac actuators PME120 AN and LME620 AN Microprocessor-controlled power electronic unit with integrated frequency

More information