1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS OVERVIEW has always been concerned with keeping a service policy for its products by means of a wide range of DRIWISA spare parts', original parts' and accessories' available with the purpose of always keeping equipment in good condition and also offering our customers efficient service and technical support through factory personnel or through an authorized representative. The company has also developed a wide variety of accessories for medium voltage enclosures and switchgears, and for DRIWISA equipment (fuse-holders, non-load break isolator switches, load break disconnector switches and grounding switches) DRIWISA spare parts, original parts and accessories are high quality and reliable, guaranteed to keep equipment in good condition for many years. F1-1

2 DRIWISA PLIERS FOR HIGH VOLTAGE FUSES WITH WALL HOLDER OVERVIEW DRIWISA pliers are used to install and remove fuses from fuse holders. DRIWISA pliers for high voltage fuses are designed according to international standards (IEC), taking into consideration the minimum safety distances that provide protection against electricity and help avoid any injuries and burns. They are designed for indoor use and are not reccomended to be used with a voltage higher than 38 Kv. DRIWISA pliers should only be held from their back end (behind the protection ring). The user must always remove the fuse/fuses when the load break disconnector switch is open, avoiding contact with the live parts. The longest distance possible should be kept when applying the fastening clamps on the high voltage fuses. The use of DRIWISA pliers does NOT mean one can forget the other safety equipment such as an insulation mat, gloves, boots and helmet for high voltage use and the user must always remember to follow all the safety rules. between 30 and 90 mm and a maximum weight of 7 kg can be handled. Before using these pliers, the safety instructions should be carefully read. The rated voltage indicated on the pliers themselves, refer to the highest system voltage they can be used on. DRIWISA pliers complywith DIN VDE 0681 part 3 standards. By turning the handle, the fastening clamps of the pliers open or close. With DRIWISA pliers, fuses with a diameter F5-1

3 DRIWISA PLIERS FOR HIGH VOLTAGE FUSES WITH WALL HOLDER Specifications Operation voltage (Vn) : Maximum fuse diameter in the fastening clamps: Maximum fuse weight: Total length: Weight: Catalog No: DW-018 Up to 30 kv 30 to 90 mm 7 kg 1500 mm 2.6 kg Notes: - The protection ring limits the isolated part of the pliers from the handle.the operator should never hold the pliers beyond this point. - - DRIWISA pliers should be perfectly cleaned and dried if necessary before being used then stored in a clean and dry place. - - DRIWISA pliers are provided with a holder to be installed on the wall near the switchgear or electrical installation in which it will be used. Dimensions HOLDING CLAMPS RED RING INSULATED PART PROTECTION RING HANDLE MOVABLE PART OF THE HANDLE F5-2

4 DRIWISA MOTOR DRIVES FOR NON-LOAD ISOLATORS AND LOAD-BREAK SWITCHES. OVERVIEW For non-load isolator switches', load break switches' and grounding switch atomization, DRIWISA has motor drive operators available, specially designed to operate DRIWISA switches. DRIWISA motor drive operators are available in two basic versions: one for installation at the input shaft of the switch (type DW and DW-763-4) with the possibility of controlling it manually through a lever by means of a hookstick. When ordering this type, please specify which version you want in the purchase order. The second version (type DW and DW-761-4) is sold separately and is installed in the inner face of the front panel of the switch cabinet, on a structural element or a beam of the cabinet's structure. It is then mechanically linked by means of a transmission rod with an articulated joint formed by a lever or tab and a yoke at each end. On top of the motor drive, a small gear box with a socket for inserting a manual crank(dw-764) allows manual or emergency operation. These are equipments of a strong construction and high reliability. Its mechanical dimensioning (nominal torque approximately 250 N-m), exceeds the usual torque requirements to control an equipment (around 120 N-m). This eases the resistance that could be shown when equipments have not been operated for a long time. The motor power is 99 W and it has a safety mechanism to avoid damage to the motor in case of mechanical malfunction and it is supplied with auxiliary contacts to send the signal to the contactor and it cuts the energy supply to the motor. All the elements are connected to identified and easily accessible terminal boards. Due to their simple design, it can be built with economical and commercially approachable elements. DRIWISA motor drive operators are perfectly lubricated in all moving parts and only require minimum maintenance. F12-1

5 DRIWISA MOTOR DRIVES FOR NON-LOAD ISOLATORS AND LOAD-BREAK SWITCHES. SELECTION CHART DW-76 - PRODUCT CODE OPERATION VOLTAGE Installation on the front panel DW V d.c. of the switchgear cabinet (for left-operated switches) Installation on the the front panel DW of the switchgear cabinet (for right-operated switches) Installation on the shaft of the switch DW (for left-operated switches) Installation on the shaft of the switch DW (for right-operated switches) Emergency manual crank DW-764 General specifications Unit c.d. Voltage: V Maximum motor current: A 1.25 Total pow er consumption: 99 W Maximum torque: N-m 250 F12-3

6 DRIWISA MOTOR DRIVES TYPE GM FOR NON-LOAD ISOLATORS AND LOAD-BREAK SWITCHES. DIMENSIONS AND INSTALLATION Switchgear Frontal cover Emergency manual drive DW-764 DW-760- Left side DW-761- Right side Switchgear lateral cover DW-762- Left side DW-763- Right side F12-4

7 DRIWISA MOTOR DRIVES TYPE GM FOR NON-LOAD ISOLATORS AND LOAD-BREAK SWITCHES. ELECTRIC DIAGRAMS F12-5

8 DRIWISA MOTOR DRIVES FOR NON-LOAD ISOLATORS AND LOAD-BREAK SWITCHES. TORQUE - CURRENT GRAPHS All the motor drives have auxiliary contacts S1 and S2, each one moved by a cog and its function is to operate the microswitch (open and close) sending a signal to the control circuit (designed and installed for the client), and the of this control circuit is to supply and cut the power to the motor. The position of the cogs is adjustable to precisely calibrate the operation of the microswitches. Important note; When using motor drives in combination with non-load switches or grounding switches, you should take into consideration all the electrical and mechanical blocking systems, in order to avoid unwanted opening or closing in dangerous situations. The control circuit has to be connected to the motor drive through the terminal boards. CURRENT (A) F12-6

9 DRIWISA CLIP ASSEMBLIES FOR HIGH VOLTAGE CURRENT-LIMITING FUSES OVERVIEW DRIWISA manufactures clip assemblies for current-limiting fuses with cap diameters of 45mm which correspond to the specified diameter by international standards (IEC, DIN), other fuses with the same dimensions can be used. Clips for DRIWISA fuses are made of pure stamped electrolytic copper (99.9%), to provide the necessary mechanical strength and have a silver-plated-finish to assure an excellent contact with a reduced ohmic resistance. They have a tempered spring system that assures adequate pressure on the contact area, to achieve the minimum contact resistance and to supply the necessary mechanical firmness. The assembling base has two holes that allow its mounting on DRIWISA standoff insulators or on insulated supports and buses. The entire assembly has a terminal on one side, either to connect directly to a bus or a cable through a connector. This versatility allows clips to be used in different ways and be widely used. When a ready to use insulated fuse mounting base is required, it is recommended to use a fuse-holder the way described in Section B. It can be used in DRIWISA install fuses or as a spare part. switches or fuse holders to Selection guide shows the different options and available versions, as spare parts or as specific parts for certain applications. F18-1

10 DRIWISA CLIP ASSEMBLIES FOR HIGH VOLTAGE CURRENT-LIMITING FUSES SELECTION GUIDE FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIGURE CATALOG No. DESCRIPTION SUGGESTED USE 1 DW Independent clip As spare part for switches 2 DW Clip with clip-holder For mounting on buses or spare part for switches 3 4 DW DW Clip with contact Clip with clip holder and single bar For mounting on insulators or spare part for switches As spare part for switches, for single fuse holder version FIG. 7 5 DW Double clip and long bar T for dual fuse As spare part for switches, for dual fuse holder version 6 DW Double clip and short bar T for dual fuse As spare part for switches, for dual fuse holder version 7 DW Extension Clip with clip-holder and long bar For install 442mm fuse length in 537mm fuse holder, single fuse version. 8 DW Extension Double clip and long bar T for dual fuse For install 442mm fuse length in 537mm fuse holder, dual fuse version. FIG. 8 F18-2

11 SHUNT-TRIP COIL FOR DRIWISA SWITCHES WITH STORED-ENERGY DRIVES (QUICK-BREAK) OVERVIEW The shunt-trip coil is used in DRIWISA load-break switches with quick-break / quick-make mechanisms, since the opening function may be effectively controlled by electrical means, to meet several requirements both for control and protection schemes. The tripping coil consists of a solenoid with a moving plunger armature which is strongly attracted to the core by the resulting magnetic field when energized. The moving piece is linked to a rod and a lever which pulls the pawl release of the stored-energy spring mechanism of the quick-break mechanism, thus tripping and opening the switch. The DRIWISA tripping coil is designed for momentary operation with DC or AC supply, during the time required for the auxiliary tripping mechanism to release and trigger the previously loaded spring drive (max. 3 sec). The DRIWISA tripping coil can be installed in load break disconnector switches with or without a fuse holder. For installation in existing DRIWISA switches, it may be ordered by the corresponding catalog number according to the attached Selection Guide. The complete kit is supplied if properly ordered for field installation. The customers are required to install the part(s) by themselves. If the customer would like to install the switch in a horizontal position (using the frame as a reference with the arcing chamber on top) or inverted vertical (using the frame as a reference with the arcing chamber at the bottom) the customer has to let us know in the purchase order. This way we can add a device which makes it possible to be installed in the required position. This only applies to switches of 400 and 630 A. For more information regarding positions please see page D1-4. The applications of shunt-trip coils integrated into load-break switches are diverse, and can work with other protection devices such as: - Protection against low voltage (27) - Protection against phase fault (47) - Protection against phase inversion (47) - Protection against overloadings (51) - Protection against low power factor (55) - Protection against overvoltages (59) - Protection against overfrecuency or low frecuency (81) The numbers between parenthesis correspond to the ANSI designations for power systems devices. F20-1

12 SHUNT-TRIP COIL FOR DRIWISA SWITCHES WITH STORED-ENERGY DRIVES (QUICK-BREAK) SELECTION CHART Complete shunt-trip coil kits for 127 VAC with pulling rod and auxiliary contact type S0, including accessories (fieldassembly kit): CATALOG CONTROL MAXIMUM VOLTAGE No VOLTAGE 7.2 KV 17.5 KV 25.8 KV 38 KV DW VAC The DW model can be used with left or right side switches. The auxiliary contact SO can only operate as a warning device and NOT as an interrupting device. You should use an contactor to operate (disconnect and feed) the shunt trip. DRIWISA does NOT supply this contactor. We recommend the use of the contactor: Siemens 3RH1122 General electrical specifications Rated Voltage : Maximum continuous operation time: Minimum Voltage: Maximum operation Current: Energy consumption: 127 V A.C. 3 sec 100 V A.C. 5 Amp 18 watts Connection diagram F20-2

13 SHUNT-TRIP COIL FOR DRIWISA SWITCHES WITH STORED-ENERGY DRIVES (QUICK-BREAK) OVERVIEW The capacitor trip unit is intended to store electric charge in a capacitor for later use in tripping a shunt-trip coil (see pages F20-1 and F20-2) when the control voltage supply has been cut or has failed. This way we are able to operate the shunt trip coil. The unit is designed to hold charge for at least 10 minutes after power supply cut and has been specially developed to deliver enough current for ONE single shot operation of shunt-tripping coils used on DRIWISA switches. It can be installed in any position because it has a frame with four holes to mount the unit. DC and AC main power supply versions are available. Output is VCD in either version, adequate for one single shot operation of the shunt-trip coil. The unit may operate in any position. F21-1

14 SHUNT-TRIP COIL FOR DRIWISA SWITCHES WITH STORED-ENERGY DRIVES (QUICK-BREAK) SELECTION CHART DW Capacitor-trip unit for 127 V AC input voltage. Electrical specifications Voltage supply Output voltage(one impulse) Charging current Charging time 127 V A.C. / V D.C V d.c. < 1 A < 100 ms Connection diagrams Option A) Control by external tripping Option B) Control by external tripping and automatic tripping when supply is suppressed F21-2

15 AUXILIARY CONTACTS FOR DRIWISA SWITCHES OVERVIEW A wide variety of applications for control and signalization in medium voltage switchgear and metal-enclosed distribution switchboards is obtained when DRIWISA load-break, nonload and grounding switches are equipped with auxiliary contacts. The design of the contact blocks, their modularity and easy installation facilitates not only factory-installed solutions, but even in field installation on existing switches to meet every need. Extending existing contact blocks when needed is easy and therefore maintenance and replacing is also simple. When selecting the switch, introduce the corresponding letter for auxiliary contacts in the code, according to the option containing the required contacts combination. When doing so, the switch will be shipped with the contacts already installed and calibrated. The auxiliary contact blocks are made of two contacts of each selected type. When more contacts of a certain type are required they must be ordered separately but using a code that identifies the type / position. When the switch is delivered, it will contain the basic block of two and the additional contacts already installed. The corresponding code numbers are described in the Selection Guide. Auxiliary contacts for DRIWISA switches are named S1, S2, S3, S4, S5 and S0, as described in the attached Selection Guide. The code letters used to specify the basic blocks are P, Q, R and S. Letter N implies no auxiliary contacts on the switch. All auxiliary contacts are 1P2T (changeover contacts) thus giving the designer the choice of using the normally open (NO) or the normally closed (NC), according to each specific need. In conclusion, the following alternatives are available for maximum flexibility: FACTORY-INSTALLED AUXILIARY CONTACTS: Use code letters P, Q, R or S in the AUXILIARY CONTACTS FIELD when filling the switch code, as described in the enclosed table and on the corresponding switch type Selection Guide. Two auxiliary contacts of each selected type S1...S5 will be installed. If more than two contacts are required for any or all types, order them separately using the corresponding part number (code) depending on the required type / position (S1, S2, S3 S4, or S5). The resulting combinations will be factoryinstalled and delivered in this way. ON-FIELD INSTALLATION OF AUXILIARY CONTACTS TO EXISTING SWITCHES: Order them by kits, using the corresponding part number (code). All kits are field-installable and include the required hardware. Each kit contains two auxiliary contacts of the corresponding type. ADDITIONAL CONTACTS OR SPARE PARTS FOR MAINTANACE: Order them by kits, using the corresponding part number (code). For field installation order according to the following selection guide. F22-1

16 AUXILIARY CONTACTS FOR DRIWISA SWITCHES SELECTION CHART SELECTED OPTION TYPE AND QUANTITY OF INSTALLED AUXILIARY CONTACTS IN SWITCH CODE S1 S2 S3 S4 S5 S0 COMMENTS N O 2 P 2 2 Q 2 2 R S FUNCTION LOCATION BASIC KIT FOR INSTALLATION Fully open switch indication Fully closed switch indication Joined to the driving shaft of the switch DW (Switch option L) DW (Switch option K) Tripping of any fuse indication Joined to the tripping shaft DW Grounding switch fully open indication Grounding switch fully closed indication Joined to the driving shaft of the grounding switch DW (Switch option L) DW (Switch option K) One auxiliary contact type S0 is always provided in switches with shunt-trip coil (Sw option "D") Sends signal to the contator once switch has opened On the shaft of the quick-break mechanism DW Without auxiliary contacts except S0 in D versions Fuse status indicator Main switch indication Grounding switch indication Main switch and fuse status indication Main switch, grounding sw, fuses indication Note: Catalog No for installation kit DW is indentified on page F22-6 according to the equipment option Electrical specifications: CONTACT TYPE : 1P2T A.C. D.C. MAX. OPERATION VOLTAGE : 250 V 125 V PERMANENT CURRENT : 10 A 10 A INTERRUPTION CURRENT : 10 A 0.5 A F22-2

17 AUXILIARY CONTACTS FOR DRIWISA SWITCHES CONTACT ARRANGEMENT CONTACT TYPES S1 AND S2 SWITCH IN FULLY OPEN POSITION: SWITCH IN FULLY CLOSED POSITION : SWITCH IN ANY INTERMEDIATE POSITION: Auxiliary contact type S0 is included only in switches with shunt-trip coil (drive mechanism type D). F22-3

18 AUXILIARY CONTACTS FOR DRIWISA SWITCHES CONTACT ARRANGEMENT CONTACT TYPES S3 FOR FUSE STATUS INDICATION: CONTACT TYPES S4 and S5 FOR GROUNDING SWITCH POSITION INDICATION: (WHEN GROUNDING SWITCH IS INTEGRATED TO THE LOAD-BREAK OR NON-LOAD SWITCHES) SWITCH COMPLETLY OPEN SWITCH COMPLETLY CLOSED Auxiliary contacts type S4 and S5 are used when the Grounding Switch is integrated to other switches. When the grounding switch is independent (type DEP.../...), the same contacts are supplied when option Q is selected. F22-4

19 AUXILIARY CONTACTS FOR DRIWISA SWITCHES PHYSICAL LOCATION OF AUXILIARY CONTACTS OPERATOR SIDE REFERENCE DESCRIPTION RIGHT LEFT 1 AUXILIARY CONTACTS S1 Y S2 DW DW AUXILIARY CONTACTS S3 DW AUXILIARY CONTACTS S4 Y S5 DW DW AUXILIARY CONTACTS S0 DW TRIP COIL DW F22-5

20 AUXILIARY CONTACTS FOR DRIWISA SWITCHES KITS OF AUXILIARY CONTACTS F22-6

21 DRIWISA DISC-TYPE MANUAL OPERATOR OVERVIEW DRIWISA disc-type operator is used to move DRIWISA grounding switches, non-load isolators and load-break disconnecting switches from outside the switchgear cabinets. The complete set consists of the following parts: - One rotating disc mechanism with lever and a base for fixation on the switchgear cabinet wall. - One operator rod to be inserted into the disc. - One set of two coupling yokes. The connection between the two yokes is performed through a ½" galvanized steel pipe, threaded at both ends, cut to the required length according to the cabinet design. The tube is not supplied in the set, because their length may vary. A nut is supplied for each yoke used to tighten the yoke. Once installed, the disc drive is operated through the operator rod, which is inserted in the hole on the disc. The rotational motion is transmitted to the disc lever, which is adjustable in steps of 25º around the axis. This lever is joined to a yoke installed on each end of the galvanized pipe, which transmits the movement to the switch operating lever, install on the shaft of the switch, thus allowing operation of the switch from outside of the cabinet. The corresponding Selection Guide describes the available versions, as well as optional accessories. The combination and adequate installation and adjustment of all parts, the right solutions for every specific case can be achieved, for right or left-side operated equipment. F23-1

22 DRIWISA DISC-TYPE MANUAL OPERATOR SELECTION CHART Cat No. Description Cat No. Description DW Complete disc operator kit, comprises of: DW (Plate Versión) DW Disc mechanism DW-904 (Plate Disc) 1 Disc mechanism DW Operating rod DW Operating rod DW Yokes DW Yokes DW-902 DW-901 DW-904 DW-903 DW DW-901 DW-902 DW-903 Disc operator set with padlock accesories, comprises of: 1 Disc mechanism 1 Operator rod 2 Yokes 1 Moving bar with eyelet 1 Fixed front half sector DW-902 DW-901 DW-903 DW-905 Note 1: Note 2: Note 3: The operating lever is supplied with each switch. If you need a operating lever order it as DW-909. Because the dimensions of the required galvanized pipe for transmission depend on the design of the cabinet, it is not included in the kit. It is recommended to use a 12.7 mm Ø (½") galvanized steel pipe threaded std. (N.P.T.) at both ends, cut to required length. The holes of the padlock on the fixed front half sector, must be done in field, once the disc mechanism is installed and the blockade positions are set. F23-2

23 DRIWISA DISC-TYPE MANUAL OPERATOR ASSEMBLY Disc operator mechanisms are mounted on a lateral support or inner column at the frontal cover of the cabinet, leaving a window in front so a part of it can stick out and be moved by the operating rod, inserting it in the disc hole. The disc operator mechanism is joined through the yokes and the galvanized steel pipe (not included) to the switch operating lever (placed on the switch shaft). It is recommended to isolate the transmission pipe using either a thermocontractile sleeve or a high voltage isolating tape. Switch operating lever Transmission pipe Frontal cover of the cabinet Switch shaft Yokes Operating rod For the equipments assembly and operation it is recommended to keep the Switch operating lever and the disc lever angles recommended in the DW-900 manual supply in each kit. The disc type operator mechanism with padlock accessories, has to be mounted and adjusted before making the holes on the fixed front half sector, to achieve the required precision. F23-3

24 DRIWISA NON-LOAD ISOLATORS GROUP OPERATED, WITHOUT FUSE HOLDERS SUBASSEMBLIES AND SPARE PARTS TYPES: DTP / CODES: DTP / Amperes ID DESCRIPTION DTP07/060 DTP15/060 DTP20/060 DTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-220 DW LIVE PARTS SET DW-121 DW-121 DW-221 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW-318 CODES: DTP / Amperes ID DESCRIPTION DTP07/060 DTP15/060 DTP20/060 DTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-225 DW LIVE PARTS SET DW-126 DW-126 DW-226 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW-318 CODES: DTP / Amperes ID DESCRIPTION DTP07/120 DTP15/120 DTP20/120 DTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-230 DW LIVE PARTS SET DW-131 DW-131 DW-231 DW STANDOFF INSULATOR WITH HARDWARE DWA-07BE DWA-15BE DWA-20BE DWA-30BE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-219 DW-319 NOTE.- FROM AUGUST-2008 THE DISIGN CHANGED. PLEASE MENTION THE SWITCH SERIAL NUMBER WHEN YOU ASK FOR SPARE PARTS, IN ORDER TO IDENTIFY THE CORRECT PART ACCORDING TO THE DISIGN. 10 F30-1

25 DRIWISA NON-LOAD ISOLATORS GROUP OPERATED, WITHOUT FUSE HOLDERS SUBASSEMBLIES AND SPARE PARTS TYPES: DTP / CODES: DTP / Amperes ID DESCRIPTION DTP07/200 DTP15/200 DTP20/200 DTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-240 DW LIVE PARTS SET DW-141 DW-141 DW-241 DW STANDOFF INSULATOR WITH HARDWARE DWA-07CE DWA-15CE DWA-20CE DWA-30CE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-219 DW-319 CODES: DTP / Amperes ID DESCRIPTION DTP07/300 DTP15/300 DTP20/300 DTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-250 DW LIVE PARTS SET DW-151 DW-151 DW-251 DW STADOFF INSULATOR WITH HARDWARE DWA-07CE DWA-15CE DWA-20CE DWA-30CE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-219 DW-319 NOTE.- FROM AUGUST-2008 THE DISIGN CHANGED. PLEASE MENTION THE SWITCH SERIAL NUMBER WHEN YOU ASK FOR SPARE PARTS, IN ORDER TO IDENTIFY THE CORRECT PART ACCORDING TO THE DISIGN. F30-2

26 DRIWISA NON-LOAD ISOLATORS GROUP OPERATED, WITHOUT FUSE HOLDERS SUBASSEMBLIES AND SPARE PARTS TIPOS: LDTP / CODES: LDTP / Amperes ID DESCRIPTION LDTP07/060 LDTP15/060 LDTP20/060 LDTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-260 DW LIVE PARTS SET DW-161 DW-161 DW-261 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW SPRING KIT FOR QUICK MAKE/QUICK BREAK MECH DW-861-J DW-861-J DW-862-J DW-862-J CODES: LDTP / Amperes ID DESCRIPTION LDTP07/060 LDTP15/060 LDTP20/060 LDTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-265 DW LIVE PARTS SET DW-166 DW-166 DW-266 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW SPRING KIT FOR QUICK MAKE/QUICK BREAK MECH DW-861-J DW-861-J DW-862-J DW-862-J CODES: LDTP / Amperes ID DESCRIPTION LDTP07/120 LDTP15/120 LDTP20/120 LDTP30/ kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-270 DW LIVE PARTS SET DW-171 DW-171 DW-271 DW STANDOFF INSULATOR WITH HARDWARE DWA-07BE DWA-15BE DWA-20BE DWA-30BE 10 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-219 DW SPRING KIT FOR QUICK MAKE/QUICK BREAK MECH DW-864-1J DW-864-1J DW-864-2J DW-864-3J NOTE.- FROM AUGUST-2008 THE DISIGN CHANGED. PLEASE MENTION THE SWITCH SERIAL NUMBER WHEN YOU ASK FOR SPARE PARTS, IN ORDER TO IDENTIFY THE CORRECT PART ACCORDING TO THE DISIGN. F31-1

27 DRIWISA NON-LOAD ISOLATORS GROUP OPERATED, WITH FUSE HOLDERS SUBASSEMBLIES AND SPARE PARTS TYPES: LDTP / x CODES: LDTP / 04x 400 Amperes ID DESCRIPTION LDTP07/06x LDTP15/06x LDTP20/06x LDTP30/06x 7.2 kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-280 DW LIVE PARTS SET DW-181 DW-181 DW-281 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 12 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW TRANSMISSION SET AND TRIPPING SYSTEM f/3 POLES DW DW DW DW SPRING KIT FOR QUICK MAKE/QUICK BREAK MECH DW-861-J DW-861-J DW-862-J DW-862-J CODES: LDTP / 06x 630 Amperes ID DESCRIPTION LDTP07/06x LDTP15/06x LDTP20/06x LDTP30/06x 7.2 kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-285 DW LIVE PARTS SET DW-186 DW-186 DW-286 DW STANDOFF INSULATOR WITH HARDWARE DWA-07AE DWA-15AE DWA-20AE DWA-30AE 12 PUSH-ROD INSULATOR WITH HARDWARE DW DW DW-218 DW TRANSMISSION SET AND TRIPPING SYSTEM f/3 POLES DW DW DW DW SPRING KIT FOR QUICK MAKE/QUICK BREAK MECH DW-861-J DW-861-J DW-862-J DW-862-J F32-1

28 DRIWISA LOAD BREAK DISCONNECTOR SWITCH GROUP OPERATOR, WITH FUSE HOLDERS SUBASSEMBLIES AND SPARE PARTS TYPES : LDTP / x (2 fuses per phase) ID DESCRIPTION LDTP07/06x... LDTP15/06x... LDTP20/06x... LDTP30/06x kv 17.5 kv 25.8 kv 38 kv COMPLETE CONVERSION KIT (to change the single fuse carrier into a double fuse carrier) to for fuse length 1 ( e = 192 mm ) DW to for fuse length 2 ( e = 292 mm ) DW DW to for fuse length 4 ( e = 442 mm ) DW DW DW to for fuse length 5 ( e = 537 mm ) DW DW CENTRAL CONNECTING TAB (w ith fuseholder) 2 DUAL TRIPPING ROCKER ARM ASSEMBLY 3 CLIP ASSEMBLY 4 NYLON LEVER Num. 5 (50 x 9.5 mm Ø, long bolt) 5 OUT CONNECTING TAB (w ith fuseholder) 6 INSULATING PLATE to for fuse length 1 ( e = 192 mm ) to for fuse length 2 ( e = 292 mm ) to for fuse length 4 ( e = 442 mm ) to for fuse length 5 ( e = 537 mm ) 7 CLIP FOR INSULATING PLATE NOTE: The conversion kits include four DW-820 clips per phase, and is supply complete. F32-2

29 DRIWISA LOAD BREAK DISCONNECTOR SWITCH GROUP OPERATOR, WITH FUSE HOLDERS TRIPPING SYSTEM TYPES: LDTP / x (1 fuse per phase) LDTP07/06x... LDTP15/06x... LDTP20/06x... LDTP30/06x... ID DESCRIPTION QY. LDTP07/12x... LDTP15/12x... LDTP20/12x... LDTP30/12x kv 17.5 kv 25.8 kv 38 kv 5 ROCKER ARM BRACKET 3 6 TRIPPING ROCKER ARM 3 10 NYLON LEVER WITH ONE BOLT 6 11 NYLON LEVER WITH TWO BOLTS 3 DW DW DW DW FIBERGLASS ROD 3 16 PUSH BAR 1 17 TENSION SPRING 1 F32-3

30 DRIWISA GROUNDING SWITCHES GROUP OPERATED SUBASSEMBLIES AND SPARE PARTS CODES: DEP / 025 integrated to DTP or LDTP switch ID DESCRIPTION DEP DEP DEP DEP kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-290 DW LIVE PARTS SET DW DW DW-291 DW QUICK MAKE DRIVE TYPE (E) DW-704 DW-704 DW-704 DW-704 F34-1

31 DRIWISA GROUNDING SWITCHES GROUP OPERATED SUBASSEMBLIES AND SPARE PARTS CODES: DEP / 000 integrated to DTP or LDTP switch ID DESCRIPTION DEP DEP DEP DEP kv 17.5 kv 25.8 kv 38 kv 1 COMPLETE POLE DW DW DW-295 DW LIVE PARTS SET DW DW DW-296 DW QUICK MAKE DRIVE TYPE (E) DW-704 DW-704 DW-704 DW-704 F34-2

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS TECHNICAL SPECIFICATION LOAD BREAK DISCONNECTOR SWITCHES WITHOUT FUSE HOLDER UIT FUSE HOLDER SECTION CONTENTS PAGE 1 General Features 3 2 Standards

More information

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS INSTALLATION MANUAL FOR DISC OPERATOR MECHANISM DW-900- November 2010 Index 1 General Description 2 2 Installation 4 2.1 Practical Method 5 2.2 Analytical

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

RBA Catalog Numbers and Information

RBA Catalog Numbers and Information 50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

I-1 DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE. Overview

I-1 DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE. Overview Overview DRIWISA high voltage, current-limiting fuses are devices with a high interrupting capacity to protect high voltage systems against short-circuits. They are selective elements for individual operation,

More information

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching

More information

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. .3 Power Breakers, Contactors and Fuses Fuses General Contents Description Fuses General Product Overview Power Fuse Eaton s roots in the medium voltage power fuse business began over 75 years ago under

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

Copper Vertical Break Switch kv A.

Copper Vertical Break Switch kv A. Bulletin DB-106C05 Type V2-C Copper Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-C APPLICATION The Cleaveland/Price V2-C is a three pole, group operated, copper vertical break

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Aluminum Vertical Break Switch kv A.

Aluminum Vertical Break Switch kv A. Bulletin DB-C106AA05 Type V2-CA Aluminum Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-CA APPLICATION The Cleaveland/Price V2-CA is a three pole, group operated, aluminum vertical

More information

1. Safety practices General Introduction Standards...3

1. Safety practices General Introduction Standards...3 1. Safety practices...2 2. General...3 2.1 Introduction...3 2.2 Standards...3 3. Technical data...3 3.1 Designation...3 3.2 Electrical ratings and dimensions...4 3.3 Fixation...6 3.4 Connecting terminals...6

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( ) DRIESCHER Outdoor Hand-Operated Actuators and Accessories Get connected http://www.driescher.com ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. (0 87 61) 6 81-0 FAX (0 87 61)

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features Vertical Break Switch Operators/Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Base mounting holes

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive Vacuum Circuit-Breakers, Type HVX 12 24 kv, of cassette design, cassette with motor drive Operating Instructions No. 531 321, Edition 09/00 Table of Contents 1 General 4 1.1 Operating Conditions 4 2 Design,

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1 Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear ABB Group February 25, 2015 Slide 1 SafeGear HD arc resistant switchgear 63 ka arc resistant metal-clad air insulated switchgear

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE

DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE HIGH VOLTAGE CURRENT-LIMITING FUSE CATALOG ! DRIWISA trademark is registered by and is protected by national and international law. The use of this trademark without written authorization by is a crime

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment General The switchgear must be suitable for 36 kv rated voltage and specifically conceived for the secondary distribution substations in M.V. with either ring or radial type networks. The switchgear must

More information

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications SERIES AZM170 Description The AZM170 Series is designed for machines/work cells where access to a hazardous work area must be controlled until safe conditions exist. Their solenoid-latching feature permits

More information

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy. Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings

More information

920 Remote Control Switches

920 Remote Control Switches 920 Remote Control Switches REMOTE CONTROL SWITCHES Service Bulletin This service bulletin for ASCO 920 Remote Control Switches explains how to replace the main s, operator coil, control s, and how to

More information

Bussmann series NH catalogue. Leadership in circuit protection

Bussmann series NH catalogue. Leadership in circuit protection Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

3.2. Current Limiting Fuses. Contents

3.2. Current Limiting Fuses. Contents .2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor

More information

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47. Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SafeGear TM Motor Control Center Arc resistant metal-clad construction SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application s SICOP Bimetal Overload Relays Type 3UA5/6 & 3UC5/6 Introduction The bimetal overload relays type 3UA5/6 & 3UC5/6 relays are indigenously manufactured and bring to the users a whole range of benefits,

More information

VersaRupter MV Indoor Switch kv, A, 40 and 61 ka Momentary Price and Order Entry Guide ABB

VersaRupter MV Indoor Switch kv, A, 40 and 61 ka Momentary Price and Order Entry Guide ABB VersaRupter MV Indoor Switch 5 38 kv, 200 1200 A, 40 and 61 ka Momentary Price and Order Entry Guide ABB Table of Contents VersaRupter Overview General Description..........................................................

More information

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7 Construction Standards Page 1 of 7.1 General.1 New buildings are to be provided with an indoor unit substation designed to accept 15kV and 25kV primary voltages, however, the primary voltage connected

More information

Instructions for Replacing

Instructions for Replacing e Instructions for Replacing Vacuum Bottle Subassemblies a on Type SJA, SJS and SJO 360 Amp Contactors l.l. 16-200-348 This l.l. includes illustrations and instructions for replacing vacuum bottle subassemblies

More information

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required! DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size. S&C Mini-Rupter es Indoor Distribution (4.16 kv through 25 kv) Selecting Standard Mounting Arrangements for Manually Operated Styles Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter

More information

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB Annexure-V (Under Two Part Bid System) Tender No: NFV/ PUR/ BEC 160546 K for VCB Technical specification for NIT SL NO 1 S.No. Description NFL requirement as per NIT Vendors Comment [Agreed / If not agreed,

More information

Series A Construction

Series A Construction Page 1 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Series A Construction 505 505 1495-F1 (1 N.O. auxiliary contact) 1495-G5 (1 N.C. early break auxiliary contact) 1495-H0 ( 1 N.C. late break auxiliary

More information

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General 13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear

More information

Control Relays Overview

Control Relays Overview Control Relays Overview DESIGN FEATURES Among the advances Agastat Control Relays offer over existing designs is a unique contact operating mechanism. An articulated arm assembly amplifies the movement

More information