COMPONENTS. Off-load Switch for Fixed Installation Title type SW
|
|
- Letitia Barnett
- 5 years ago
- Views:
Transcription
1 COMPONENTS Off-load Switch for Fixed Installation Title type SW
2 General information The SW off-load switch is a complete range designed to cover all the applications to be met in DC traction power substations and other industrial applications. Its modular concept enables to build single pole or double pole disconnect switches, change-over switches or disconnect and earthing switches, for insulation voltages 3000 Vdc/ac or 4800 Vdc/ac and rated thermal currents from HV connection 000 to 8000 A. Installed inside cubicles, the SW switch can be operated either manually or electrically, and the customer can select among standard options safety interlockings made via key locks and/or electromagnets. The severe testing procedures applied for the type testing as well as for the serial testing make the SW switch a safe component with a unique design and a high level of reliability. Main plate Control system HV moving contact HV connection Auxiliary contacts Applications disconnect switch to connect / disconnect electric circuits (ex.: isolate / connect a third rail, catenary or transformerrectifier groups). change-over switch to select electric circuits. disconnect and earthing switch to connect / disconnect and earth electric circuits. Disconnect switch Change-over switch Disconnect and earthing switch Main features Rated operational voltage 800 Vdc and 3600 Vdc Conventional free-air thermal current from 000 A to 8000 A Safe with a high rated insulation voltage 3000 Vdc and 4800 Vdc Safe with the high voltage circuit separated from the low voltage circuit High rated short-time withstand current value or pole versions Optional locking of the main contacts available with either key and/or electromagnet High modularity to cover all necessary variants and options Silver-plated high voltage connections Self cleaning contacts High mechanical durability: cycles minimum Simple design with reduced number of parts Compact size Registered models (registered community design) Reference standards: EN503-/-3
3 High modularity The figures on the page show the basic configuration of each, and device (for a current of 000 A and a voltage of 800 Vdc). All these devices are also delivered in other configurations of current, voltage, operation and number of pole, thanks to a high industrialized modularity as shown below. Selection of rated voltage 800 V 8000 A Selection of rated thermal current 6300 A 3600 V 000 A 4000 A Selection of operation Manual mode Selection of pole number pole Electric mode pole Complete SW range Rated voltage U Ne [V] Conventional free air thermal current I th [A] Type pole pole pole pole pole pole pole () () can be used only for switching between equipotential circuits. 3
4 Data for product selection MAIN HIGH VOLTAGE CIRCUIT Symbol Unit SW...0 SW...40 SW...63 SW...80 Rated voltage - U Ne [Vdc] 800 or or and Rated insulation voltage - U Nm [V] 3000 or or and Rated service current I Ne [A] Conventional free air thermal current () I th [A] Peak and rated short-time withstand current () Î Ncw [ka] I Ncw [ka] t [s] Overvoltage category OV4 OV4 OV4 OV4 Rated power-frequency withstand voltage (3) - Pole - pole U a [kv rms ].0 (4) /. (5).0 (4) - Pole - earth U a [kv rms ] 9. (4) / 8.5 (5) 9. (4) Rated impulse withstand voltage (. / 50 µs) - Pole - pole U Ni [kv] 4.0 (4) / 48.0 (5) 4.0 (4) - Pole - earth U Ni [kv] 0.0 (4) / 40.0 (5) 0.0 (4) () At T amb = +40 C and tested with high voltage connection according to standard IEC/EN () For specific values of the earthing pole, refer to the figure and table of the page 5 (3) At 50 Hz and during minute (4) For U Ne = 800 Vdc (5) For U Ne = 3600 Vdc LOW VOLTAGE AUXILIARY CIRCUIT Control circuit (motor and optional electromagnet lock) Nominal voltage U n [Vdc] 4, 48, 60,, 5, 0 [Vac] 30 (50/60 Hz) Range of voltage [0.8 -.] Un Motor nominal closing/opening power (dc only) [W] 5 (0 for Vdc) (ac only) [W] 90 Mechanical closing time (6) t c [s] < 3 Mechanical opening time (6) t o [s] < 3 Electromagnet nominal power (dc and ac) [W] ~4 (6) For motorized version, at nominal control voltage = U n and T amb = +0 C Auxiliary contacts for main circuit and optional locks Type of contacts (refer to definition page ) Change-over Rated voltage [Vdc] 4 to 0 [Vac] 30 Conventional thermal current I th [A] Maximum breaking capacity at Vdc and t=5 ms [A] 0.75 Minimum let-through current at 4 Vdc (7) [ma] (silver contacts) (7) For dry and clean environment Low voltage interface Type of connection Direct for auxiliary contact Terminal block for motor Insulation Rated power-frequency withstand voltage (8) U a [kv rms ] (8) At 50 Hz and during minute OPERATING CONDITIONS Installation Indoors Altitude [m] <400 Working ambient temperature T amb [ C] -5 to +40 Humidity Class 5K Pollution degree PD4 Minimum mechanical durability N Cycles
5 Peak and rated short-time withstand current of the earthing pole Connection of earth cable on top Connection of earth cable on bottom The earth connection can be a cable or a flexible connection according to the current. The values of the peak and rated short-time withstand current are depending on the position of the earth connection: Symbol Unit connection of earth on top: I Ncwe [ka] Î Ncwe [ka] t [s] connection of earth on bottom: I Ncwe [ka] Î Ncwe [ka] t [s]
6 Information for product integration Main dimensions The DIN-ISO 768- coarse tolerances are applied to these dimensions. All dimensions are in mm. Note! Each SW can be equipped with manual or motorized (dc or ac) operation xm xm xm xm xm xm pole version configurations SW.8.0 SW.8.0 SW SW.8.40 SW.8.40 SW SW.8.63 SW.8.63 SW SW.8.40 SW.8.40 SW SW.8.80 SW.8.80 SW pole version configurations SW.8.0 SW.8.0 SW ,5 7,5 7, xm xm xm 7,5 7,5 7, SW.8.63 SW.8.63 SW ,5 7,5 7,5 SW
7 SW xm 6,5 95 7, pole version configurations pole version configurations
8 Operations DC electric mode A 4 4 A A A B A SWx pole SWx pole SWx pole SWx pole SWx pole SWx pole SWx pole pole pole pole pole pole pole B C B B B SW...36: 43 SW...8: (SW.8...) SW...36: 43 SW...8: (SW.8...) SW...36: 43 (SW.8...) SW...8: SW...36: 43 (SW.8...) SW...8: , ,4 44, C C C C Details of the high voltage connections The busbars or cables must be mechanically fixed outside the SW disconnector, and their contact surface must be parallel to the HV connections. For all devices SW...40 SW...63 SW xØ earthing pole M 44,4 R4 R R R 3,7 43,743,743,7 Top view Top view Removable handle 364 Side view Front view AC electric mode 364 Manual mode
9 Details of the earth connection on the base plate Ø 5 5 Fixation system The SW series switches are fixed vertically as shown here by means of M screws. The two or three fixing supports must be in a flat level to eachother. Examples of executions: - Weights MA [kg]: ± kg MO [kg]: ± kg pole pole * * MA [kg]: ± kg MO [kg]: ± kg pole pole * On request MA [kg]: ± kg MO [kg]: ± kg pole pole MA: manual operation MO: electric operation Details of the low voltage electrical interfaces and motor control. The wires for the auxiliary switches of the main circuit are connected directly onto them.. In electric version only, the wires for the motor control are connected into this terminal. 3. The wires for the auxiliary switch of optional locks are connected directly onto them
10 Control diagram for DC voltage motor As the motor needs to be dynamically braked, make the external circuit (II) as shown on this diagram. M I 3 4 J 3 4 K Auxiliary contacts of the main circuit 4 4 A B 4 C D E F A K K A II A + A + Un + I. Provided by Sécheron on SW. II. The control contactors K and K are provided by the customer. Both contactors must be mechanically interlocked to avoid them to be triggered at the same time; and each of them must have three NO contacts. Control diagram for AC voltage motor As the motor needs to be dynamically braked, make the external circuit (II) as shown on this diagram. M U V W J K I Auxiliary contacts of the main circuit A B C D E F U V W B K K O O K K A II K K A A A N Un~ L I. Provided by Sécheron on SW. II. The control contactors K, K, O and O are provided by the customer. Each of the K and K contactors must have two NO and one NC contacts.
11 Options (subject to additional costs) The SW series can be equipped with two different types of systems to lock the HV moving contact in open and/or in closed positions. Both types are detailed below as well as the different available configurations. Locking systems Description Key lock system The keys can be removed only in locked positions (opened and/or closed) of the moving contact. The key rotation drives a rod that mechanically locks the movement of the HV moving contact. A change-over auxiliary switch indicates the locking status of the lock system. Electromagnet lock system The electromagnet activates a rod that locks the HV moving contact in a defined position (open and/or closed). When the electromagnet is energized, the main contact is unlocked and can then be operated. A change-over auxiliary switch indicates the locking status of the lock system. Manual lock (for manual operated device) For units operated manually and where no key lock nor locking electromagnet is selected to lock the SW in closed position, Sécheron for safety reason will systematically deliver the device equipped with a manually operated system locking the SW in closed position. When locked, an auxiliary switch will be activated which signal must be integrated by the customer in the control scheme to have the manual locking and SW closed position be interlocked. Locked positions of the HV moving contact These symbols show in which position the HV moving contact is locked: Closed position of the HV moving contact Open position of the HV moving contact in open position in closed position in open and closed positions Positions of the lock systems on the SW The key and electromagnet locks systems are located in upper position or lower position on the main plate. If only one lock system is selected, it will be always located in the lower position. If a second lock system is selected, it will be located in the upper position. The configuration table hereunder shows also where the chosen lock system is located according to your choice of lockings systems. Configurations Upper position Lower position Designation code and positions of the locking systems, in function of the selected lock system and the selected locked position of the HV moving contact: Key lock system Electromagnet lock system Designation code in Lower position in Upper position in Lower position in Upper position standard option () A B () C D E F G H I () For this configuration combined with a manual operation of the SW, the device will be automatically delivered with a manual lock.
12 Designation code for ordering Designation code information Be sure to establish the designation code from the latest version of our brochure by downloading it from the website: Be careful to write down the 3 digits for the type designation code when placing your order. It could be, for technical reasons, that some configurations of variants and options indicated in the designation code cannot be combined. For other configurations not described in the brochure, please contact Sécheron. Designation code (options are subject to additional costs) - Order form Line Description Designation Standard Options Customer s choice Product type SW SW Application Disconnect switch S Change-over switch I Disconnect and earthing switch G Rated operational voltage () 800 Vdc Vdc 36 3 Conventional free-air thermal current (at T amb = +40 C) () 000 A A A A 80 4 Operation Manual MA Electric MO 5 Number of pole () pole pole 6 Control voltage for electric operation and optional electromagnet locks (Manual operation and without electromagnet lock) Not applicable Z 4 Vdc A 48 Vdc C 60/64 Vdc G Vdc E 5 Vdc R 0 Vdc J 30 Vac - 50 Hz T 30 Vac - 60 Hz U 7 Locking of HV moving contacts No () 0 One key lock locking the open position B One key lock locking both positions C One electromagnet locking both positions I For other selection, refer to the codification table on page... 8 Key codification (If no key lock selected in line 7) Not applicable Z (If key lock selected in line 7) No 0 (If key lock selected in line 7) Yes () Refer to page 3 for the possible configurations. () For this configuration combined with the selection of MA code line 4, the device will be automatically delivered with a manual lock. Example of customer s choice: SW I 8 40 MO J B Line: The bold characters of the designation code define the device type. Place and date: Name: Signature: SP880098BEN_E Sécheron SA Rue du Pré-Bouvier 5 4 Satigny - Geneva CH-Switzerland Tel: Fax: info@secheron.com This This document is is not not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the the right to to modify and/or improve the the product, whose characteristics are are described in in these documents, as required by new technology at any time. It It is is the purchaser s responsibility to to inform himself, no no matter what what the the circumstances, of of the the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our «General Delivery Conditions». Copyright Sécheron SA
COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS
COMPONENTS Multi-functional Main AC Switch for rolling stock Type MACS GENERAL INFORMATION MACS is a platform for Main AC Switch installed on electric rail vehicles running on AC networks. The AC vacuum
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationSUBSTATIONS. Energy Storage System
SUBSTATIONS Energy Storage System ENERGY STORAGE SYSTEM Description The purpose of the Energy Storage System (E.S.S.) is to collect and store energy generated during the braking sequence of a vehicle such
More informationContactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control
Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationContactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en
Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3
More informationFA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance
F Off-Load Switches Up to 8000 and C/DC Expertly engineered for reliable performance For more than years has been providing safe and reliable solutions for switching and disconnecting high power. High
More informationCOMPONENTS. High-speed DC circuit-breakers for Rolling Stock Type UR6, UR10 & UR15
OMPONNT Highspeed circuitbreakers for Rolling tock Type UR, UR & UR General information UR, UR and UR are highspeed current limiting circuitbreakers with natural cooling, trip free, single pole, bidirectional,
More informationOutdoor vacuum breaker for railway applications - FSK II
Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationContactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en
Contactors C110B/80, C110B/120 C110B/200, C110B/00 Single pole DC NO contactors for industrial trucks Catalogue B71.en 42 C110B Series DC NO contactors for battery voltages C110B Series contactors are
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationPower distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly
NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More informationSurge arrester POLIM-H..SD
Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationFor Info: Phone: Fax:
Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC
More informationCATALOGUE. ON Medium Voltage Outdoor Disconnectors
CATALOGUE ON Medium Voltage Outdoor Disconnectors 2 O N M E D I U M V O LTA G E O U T D O O R D I S C O N N E C TO R S ON MEDIUM VOLTAGE OUTDOOR DISCONNECTORS 3 Table of conteants 004 1. Introduction 004
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage
More informationSurge arrester POLIM-H.. ND
DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More information500V / V /
LOAD BREAK SWITCHES 125-630 A TECHNICAL DATA ATEX RoHS Compliant 2002/95/EC LOAD BREAK SWITCHES 16A 25A 40A 63A 80A 125A 160A KU / KU / KU / KU / KU / KU / VKA / VKA / KUE KUE KUE KUE KUE KUE EVA EVA VKA
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationxxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads
22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More information132/11 kv, 25 MVA MOBILE SUBSTATION
File name: Mob EN katalog1 Zagreb, 11.11.2014. Page: 1 od 9 Summary Mobile substation consists of two semitrailers. One trailer is for 132 kv equipment (HV equipment) and another trailer is for medium
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationContactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.
Connect - Contact - Control Contactors CT5/0, CT0/0 CT5/0, CT0/0 CT5/0, CT0/0, and pole power contactors for AC and DC Catalogue C0.en Power contactors for AC and DC, Series CT Owing to a new blowout technology,
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationSolenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11
2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.
DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationIndoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A
Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3
More informationDBM Range 1500VDC (13,5kA to 20kA)
Load Break Switches For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time on-load disconnectors.these devices offer high performances and robustness for
More informationGE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work
GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationHigh voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv
High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv PASS M0S 252 kv Innovation In today s market, the HV substation is increasingly becoming a key element
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationW Datasheet: DIN Rail Contactors, series AMPARO
W Datasheet: DIN Rail Contactors, series AMPARO W SCHRACK-INFO For suiting of fans, pumps, heating & lighting Noise reducing design Low vibration on DIN-rail 230V 50/60Hz oder 24V 50/60 Hz coil DIN-Rail
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationSurge arrester POLIM-C.. HD
DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10
More informationB kv Gas-insulated Substations
72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationDisconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)
High Frequency Disconnectors For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationSwitch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV
Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads
More informationGas Insulated Metal-clad Switchgear, HMGS!
Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,
More informationBenefits, typical uses
R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationSwitchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.
www.siemens.com/medium-voltage-switchgear Switchgear Type 8BT1, up to 24 kv, air-insulated Medium Voltage Switchgear Catalog HA 26.31 2012 Answers for infrastructure and cities. R-HA26-013. eps Contents
More informationSYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.
SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3
More informationSU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489
MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationSF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch
FIL3 - S FIL3 D Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 24KV SF6 Load Break Switch Content 1. About Us 2. Load Break Switch Introduction 3. FIL3 product overview 3.1. Advantages
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationMini contactors B6, BC6 with 3 pole
Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,
More informationB Mini Contactor V Hz
ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationSurge arrester POLIM-H..N
Data sheet Surge arrester POLIMH..N Technical data Arrester class SH, Station High Line discharge class (LD) 4 Nominal discharge current I n (8/20 µs) 20 ka peak Repetitive charge transfer rating Q rs
More informationBreakers and Switches. Switches Change-over and transfer switches
Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic
More informationProducts and solutions for photovoltaic applications
Products and solutions for photovoltaic applications Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components
More informationB kv T&D GAS INSULATED SWITCHGEAR
GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationDS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)
DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To
More informationCircuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.
Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical
More information