PRODUCT CATALOGUE AUSTRALIA

Size: px
Start display at page:

Download "PRODUCT CATALOGUE AUSTRALIA"

Transcription

1 AUSTRALIA INSULATION PIERCING CONNECTORS LOW VOLTAGE INSULATED SERVICE FITTINGS LOW VOLTAGE WATERPROOF CONNECTION SYSTEMS SERVICE FUSE HOLDERS LVABC HARDWARE SHEAR BOLT CONNECTORS PRODUCT CATALOGUE PERSONAL SAFETY EQUIPMENT INSULATING GLOVES 00V INSULATED TOOLS INSULATING MATS EARTHING SYSTEMS DETECTORS AND INSTRUMENTS ELECTRICAL SAFETY EQUIPMENT

2 PRODUCT CATALOGUE w 0705 WELCOME TO SICAME AUSTRALIA PTY LTD THE NEW GENERATION OF OVERHEAD AND UNDERGROUND SEALED INSULATION PIERCING CONNECTORS AND FITTINGS Sicame Australia Pty Ltd has established a strong reputation as the leading manufacturer and supplier of Low Voltage Aerial Bundled Cable (LVABC) Insulation Piercing Connectors and associated equipment in Australia. In response to the growing trend toward the adoption of Overhead Aluminium XLPE Service Cable by numerous supply authorities, Sicame Australia has developed a complete range of products specifically designed for the purpose. This system allows a safe, economic and speedy installation of a customer to overhead mains with provision for cable connection, support and fusing at both the house end and pole end. These products have been tested to the relevant Australian Standards for connectors and hardware as well as European and American Standards. IPC products have been tested in compliance with AS4396 (Int.) 996 for IPC s. This catalogue will guide you through the range of overhead and underground connectors and other products that are currently approved and utilised by your local electricity utility. We commend these products to you and your customers. Robert Battle Managing Director The team at Sicame Australia headquarters in Queensland

3 CATALOGUE INDEX I SECTION A - LVABC CONNECTORS & FITTINGS A TTD series IPCs A2 NTD series IPCs A3 In Line Piercing Connectors and Industrial Mains Box A4 Multi-tap IPCs & Earthing A5 LVABC Fuse Switch Disconnectors A6 LVABC Fuse Switch Accessories SECTION B - SERVICE FITTINGS B House Service Connectors B2 CAW & CCW series service connectors B3 Mains Connection Boxes B4 Service Fuse Holders SECTION C - PRE-INSULATED FITTINGS C MJPB & MJPT series links C2 Pre-crimped links and tools C3 MEPCN series C4 CPTA & CPTAU series lugs SECTION F - STRAIN & TERMINATION FITTINGS F Service termination clamps F2 Mains termination & suspension clamps SECTION G - HARDWARE G Eye bolts, J & Q hooks, brackets G2 Eye nuts, weak links SECTION H - TIME AND LIGHT CONTROLS H P.E. Cell - Enclosed light arrestors SECTION J - CATU SAFETY EQUIPMENT J-J4 Personal Safety J5-J7 00V Insulated Tools SECTION K - EARTH Systems Accessories K-K6 Earth Set Accessories K7 Earth Clamps K8 Earth and Stick Bags K9 Lanyards SECTION D - UNDERGROUND CONNECTORS D MUCI Series submersible D2 Resin Filled Service Tee Joint D3 Bi-form & Tri-form connectors D4 BST & LVM Mechanical Branch Connectors D5 MF Series Mechanical In-Line Connectors D6 UM Series Mechanical In-Line Connectors D7 MF5 HV Mechanical Connectors D8 MF7 HV Mechanical Connectors D9 ML Series Mechanical Connectors (Lugs) D WB, 2 & 3 Series - Mains to Mains Branch Connectors D WB4 Mains to Mains Branch Connector D2 WS2 - Mains to Service Branch Connector D3 WS3 - Mains to Service Branch Connector D4 WS4 - Mains to Service Branch Connector D5 WS5 - Mains to Service Branch Connector D6 Protective Covers SECTION E - TOOLS & ACCESSORIES E Spanners, testers and wedges E2 Cutters and Strippers E3 Stringing tools E4 Stringing tools E5 Jointing Tools E6 Battery Operated Driver

4 LVABC CONNECTORS TTD Series A For Connecting INSULATED MAINS to INSULATED MAINS or INSULATED SERVICES The Sicame TTD range of insulation piercing connectors (IPCs) provide a fast, convenient and reliable method of connecting overhead low voltage mains to services or other mains. All common types of conductors can be interconnected, including insulated aluminium or copper. The connectors have been tested to AS4396 and are approved for use by Australian power distribution utilities (Consult for further details). TTD SERIES INSULATION PIERCING CONNECTOR: Application: Mains cable: Insulated copper or aluminium Tap cable: Insulated copper or aluminium Features: * Provides a fully sealed, waterproof connection * No need to strip cable to make the connection * Simultaneous piercing on main & tap * Torque controlling shear heads on all bolts * Tightening bolts do not come into contact with live components * Captive end cap for protection of tap cable, which can be mounted on either side. * Fully bimetallic * Stainless steel fasteners Testing Specification: Tested to AS4396 Product Mains Cable (mm 2 ) Branch Cable (mm 2 ) of Bolts Bolt Pack TTD05XFA 6 to 95.5 to M8 2 TTDXFA 6 to 54 6 to 35 M8 2 TTD5XFA 25 to 95 6 to 35 M8 2 TTD20XFA 35 to to 95 M8 2 TTD24XFA 50 to 50 6 to 35 M8 2 TTD25XFA 50 to to 95 M8 8 TTD30XFA 25 to to 95 2 M8 TTD34F * 50 to 50 6 to 35 2 M8 TTD35XFA 50 to to 95 2 M8 4 TTD40XFA 50 to to 50 2 M8 4 TTD43XFA 70 to to 95 2 M 4 TTD45XFA 95 to to M 4 TTD55FJA* M 4 *Galvanised fasteners Installation Notes: When using 2 bolt connectors from this range, each bolt must be tightened a /4 to /2 turn alternately, until the shear head operates. For tightening the shear head bolts, use only a 3mm AF, six sided hexagon socket (7mm AF for models TTD43XFA, TTD45XFA & TTD55FJA models). For double insulated cables, the outer sheath should be removed before applying the connector. TTD5XFA TTD30XFA Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

5 LVABC CONNECTORS NTD Series A2 For connecting BARE MAINS to INSULATED MAINS or INSULATED SERVICES The Sicame NTD range of insulation piercing connectors provide a fast, convenient and reliable method of connecting overhead low voltage mains to services and other mains. All common types of conductors can be interconnected, including bare aluminium or copper mains. The connectors have been tested to relevant standards and are approved for use by Australian power distribution utilities (Consult for further details). NTD SERIES INSULATION PIERCING CONNECTOR: Application: Mains: Bare copper or aluminium Tap: Insulated copper or aluminium Features: * Provides a fully sealed, waterproof connection on the tap. * No need to strip cable to make the connection * Simultaneous piercing on main & tap * Torque controlling shear heads on all bolts * Tightening bolts do not come into contact with live components * Captive end cap for protection of tap cable, which can be mounted on either side. * Fully bimetallic * Stainless steel fasteners Installation Notes: When using 2 bolt connectors from this range, each bolt must be tightened a /4 to /2 turn alternately, until the shear head operates. For tightening the shear head bolts, use only a 3mm AF, six sided hexagon socket (7mm AF for models NTD43XFA and NTD45XFA). For double insulated cables, the outer sheath should be removed before applying the connector. Product Type Bare Conductor (mm 2 ) Diameter Insulated Cable (mm 2 ) Connectors for Bare Copper Mains No. of Bolts Bolt Pack NTDF * Cu 7 to to.0 6 to 35 M8 2 NTD30XFA Cu 7 to to to 95 2 M8 NTD35XFA Cu 50 to to to 95 2 M8 NTD40XFA Cu 50 to to to 50 2 M8 4 NTDAF * Alu 6 to to to 35 M8 2 NTD30AXFA Alu 7 to to to 95 2 M8 NTD35AXFA Alu 50 to to to 95 2 M8 NTD40AXFA Alu 50 to to to 50 2 M8 4 NTD43AXFA Alu 95 to 240 NTD45AXFA Alu 95 to 240 Connectors for Bare Aluminium Mains 2.5 to to 9.6 *Galvanised fasteners NTD30XFA 35 to 95 2 M 4 95 to 50 2 M 4 NTD35AXFA NTDF Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

6 LVABC CONNECTORS ILC Series A3 IN-LINE PIERCING CONNECTOR A general purpose in-line piercing connector for aluminium or copper insulated cable in the range 6-95 sq mm. Piercing connectors both sides Employs proven shear head technology Fully waterproof Complies with relevant sections of AS4396 Fully insulated - no exposed live parts No crimp tools required Fits mains box below Product Cable Range (sq mm) Bolt Head A/F Pack (pcs) ILC to 95 3 Installation Notes: Use only a 3mm AF, six point hexagon socket to tighten bolts. All other connections made on the service and consumers cable must also be waterproof to prevent moisture ingress through the cable into the connector. ILC PHASE INDUSTRIAL MAINS BOX FOR IN-LINE PIERCING CONNECTORS Fully insulated connection system IP66D rated Designed to house the ILC 695 (see above) Fully UV Stabilised Protects connectors from accidental damage or contact Ideal for connecting commercial and industrial 200Amp services Rear entry of consumer mains cable Protects consumer mains cables from UV Water shedding Attractive design Supplied complete with 4 x ILC 695 connectors Product MCB/2ILC MCB3/4ILC Single phase Industrial MCB supplied with connectors Three phase Industrial MCB supplied with connectors of ILC695 connectors included Pack (pcs) MCB3/4ILC Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

7 LVABC CONNECTORS Multi-ports and Earthing A4 MSC SERIES - MULTIPLE SERVICE Mains: Insulated copper or aluminium Bare copper or aluminium Branch: Insulated copper or aluminium * Resealable test point * Reduces pole top congestion * Up to 4 independent taps available MSCA/5050X Product Mains Cable Type Mains Cable Range (mm 2 ) Branch Cable Range (mm 2 ) Pack MSCI/3595X LVABC 25 to 95 4 x 6 to 35 MSCI/5050X LVABC 50 to 50 4 x 6 to 35 MSCC/795X Bare Copper 7 to 95 4 x 6 to 35 MSCC/5050X Bare Copper 50 to 50 4 x 6 to 35 MSCA/5050X Bare Aluminium 50 to 50 4 x 6 to 35 EPC SERIES - Earth/Temporary Bond Mains: Insulated copper or aluminium Bond: To any suitable cable using integral lug connecting bolt *Fully heat cycle and short circuit tested Product Mains Cable Range (mm 2 ) Bonding Bolt Pack EPC to 95 M2 2 EPC to 85 M2 2 Both products supplied with suitable IPC TT2D SERIES - Twin Tap IPC Mains: Insulated copper or aluminium Branch: Insulated copper or aluminium Product Mains Cable Range (mm 2 ) Branch Cable Range (mm 2 ) Pack TT2D83XF3A 25 to 95 2 x 6 to 35 2 TT2D87XF3A TT2D87XF3A 50 to 50 2 x 6 to 35 2 DTA TWIN TAP ADAPTOR Use with most IPCs to provide two independent taps. Product Branch Cable Range (mm 2 ) Pack DTA2/635 DTA2/635 2 x 6 to 35 2 TTDx-CC SERIES - Test / Earth Tap Mains: Insulated copper or aluminium Branch: Bayonet style connecting port for temporary earths or test points * includes phase/neutral identification tags TTD2-CCXA Product Mains Cable Range (mm 2 ) Tap-off Fitting Type Pack TTD-CCXA 6 to 35 4mm male bayonet TTD2-CCXA 35 to 95 4mm male bayonet TTD3-CCXA mm male bayonet Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

8 LVABC MAINS FUSE SWITCHES A5 60A, 250A & 400A Fuse Switches The full range of ADC Krone LVABC Fuse Switches Fully insulated On-load switching capability Corrosion resistant connections One or three pole units available Suits standard hook stick Full range of accessories available Utility Approved Fuse Switches Product Rating Poles Cable Range Cable Connection Method Notes FSD KGH60/T 60 A x 6-95 sq mm Al/Cu Tunnel type Integral mounting bracket FSD KGH60/3T-L 60 A 3 x 6-95 sq mm Al/Cu Tunnel type Includes mounting bracket FSD KGH60/3P 60 A 3 x sq mm Al/Cu IPC type Includes mounting bracket FSD KGH250/3P 250 A 3 2 x sq mm Al/Cu IPC type Includes mounting bracket FSD KGH400/L 400 A 2mm stud for lug Max lug width 40mm FSD KGH400/3L 400 A 3 2mm stud for lug Max lug width 40mm, includes mounting bracket FSD KGH400/3TP 400 A 3 2 x sq mm (in) Al/Cu 2 x sq mm (out) Al/Cu Tunnel type (in) IPC type (out) Includes mounting bracket FSD KGH400/3PT 400 A 3 2 x sq mm Al/Cu Pillar terminals FSD KGH400/3P-LINK 400 A 3 2 x sq mm Al/Cu IPC Includes mounting bracket link storage kit fitted to lower housing Full technical specifications available on request.

9 FUSE SWITCHES ACCESSORIES A6 Mounting Brackets FMB KGH60 FMB KGH400 FCA KGH400 FMB APR630 Triple pole mounting bracket for three60a fuse switch units, includes hardware Triple pole mounting bracket for three400a fuse switch units, includes hardware Cross arm mounting bracket for one 400A switch fuse unit. Mounting bracket for three APR630/ switches P/N: FMB KGH60 Solid Links FCL 250 FCL 400/630 Solid connecting link 400A/630A 2 FCL KGH-LINK BOX Connecting-Link Storage Kit (for fitting to lower housing of switch) FCL 250 Solid Connecting link 250A Fuse Cartridges Rating Suitable for FSD FC 60NH00G 00 FC 60NHG FC 200NHG 60A 60A 200A KGH60 KGH250, KGH400 KGH250, KGH400 FC 250NHG 250A KGH250, KGH400 FC 35NH2G 2 35A KGH400 FC 400NH2G 2 400A KGH400

10 SERVICE FITTINGS HSC Series B The HSC series of connectors have been specially designed to connect consumers mains (house side) to insulated overhead service mains (service side). Fully insulated and equipped with torque control shear-head bolts, the HSC is safe and easy to use. No stripping of insulation is required on the service mains side. The consumers mains side requires 7mm of insulation to be stripped. HSC SERIES Application: Service side: Insulated copper or aluminium Mains side: Consumers mains (house) cable Features: * Shear heads on both connections * Complies with relevant sections of AS4396 * Fully bimetallic * Easily fits into Sicame Australia mains boxes (MCB Series). * Totally insulated and waterproof * IP67 rated Product Consumers Mains Cable House side) (mm 2 ) Service Side Tap Range (mm 2 ) Copper Earth Tail Length Lug Hole Bolt Head A/F Bonding Tail (mm 2 ) HSC435 4 to 35 6 to 35 N/A N/A 3 N/A HSC435/ 4 to 35 6 to HSC435/O 4 to 35 6 to HSC435/P 4 to 35 6 to HSC435/T sq mm tail 6 to N/A 3 N/A HSCH Gripping handle for HSC435 & HSC435/T Pack (pcs) Testing Specification: Relevant sections of AS4396 Installation Notes: Use only a 3mm AF, six point hexagon socket to tighten bolts. All other connections made on the service and consumers cable must also be waterproof to prevent moisture ingress through the cable into the connector. HSC435/ HSC435/O HSC435/P HSC435/T HSCH HSC435 NEUTRAL BONDING ALTERNATIVES Alternative products for providing for the neutral bond. TTDNBKX/2 Service Side Tap Range (mm 2 ) Copper Earth Tail Length Lug Hole Bolt Head Stainless Steel A/F TTDNBKX 6 to TTDNBKX/2 6 to Pack (pcs) Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

11 SERVICE FITTINGS CAW and CCW Series B2 The CCW and CAW series of connectors have been specially designed to provide a waterproof connection between insulated overhead services to a variety of bare overhead mains. Both single and double tap models are available. CAW SERIES Mains: Bare aluminium Service: Insulated copper or aluminium * Piercing connector on service tap * Complies with relevant sections of AS4396 * Disconnection of service by easy removal of the connector from the mains * Two tap (CAW235) model available * Simple M8 socket operation CCW SERIES Mains: Bare copper Service: Insulated copper or aluminium * Piercing connector on service tap * Complies with relevant sections of AS4396 * Disconnection of service by easy removal of the connector from the mains * Two tap (CCW235) model available Product CAW35 CAW235 CCW35 CCW235 Mains Range Service Taps Pack Area OD Range Stranding Quantity (mm 2 ) (mm 2 ) (pcs) 7/.75 to 9/3.75 Al 7/.75 to 9/3.75 Al 7/.00 to 9/3.00 Cu 7/.00 to 9/3.00 Cu CCW35 Connectors for Bare Aluminium Mains 6 to 2 5 to 9 6 to to 2 5 to 9 6 to Connectors for Bare Copper Mains 5.5 to 35 3 to 5 6 to to 35 3 to 5 6 to 35 2 CCW235 Installation Notes: Use only a 3mm AF, six point hexagon socket to tighten bolts. All other connections made on the service and consumers cable must also be waterproof to prevent moisture ingress through the cable into the connector. CAW235 CAW35 Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

12 SERVICE FITTINGS Mains Connection Boxes B3 Single and three phase environmental base and cover for the protection of consumer mains suitable for 6 to 35mm 2 cable. Each unit contains the HSC series (House Services Connector) providing a fully sealed bimetallic connection of copper consumer mains to Al or Cu services. MCB SERIES - MAINS CONNECTION BOX * Fully insulated connection system * Plug in HSC s providing bi-metal connection of service cables and consumers mains * Base suitable for rear entry of consumers mains * Eliminates UV degradation of PVC consumers mains * Cover allows for easy exit of bonding tail HSC435/ series * Heavy duty polyamide UV stabilised construction * Mains box is IP66 rated * Connectors are IP67 rated Product MCB/2H MCB3/4H Single phase MCB supplied with connectors Three phase MCB supplied with connectors of HSC435 connectors included Pack (pcs) MCB/2H MCB3/4H Use only a 3mm AF, six point hexagon socket to tighten the HSC bolts. Recommended tool for MCB connectors: RPS3/7-6H or RPS3/7-6SH A small flat blade screw driver is required to remove the MCB cover.

13 SERVICE FITTINGS PFV Series B4 Pole or house mounted fuse holders and accessories. 0 amp single phase, pig-tail stick operated, service fuse for house or pole mounting. PFV SERIES SERVICE FUSE HOLDER Application: Insulated XLPE aluminium or copper cables, Suitable for mounting on pole or house using appropriate bracket. Primary House Service Fuse Features: * Range of brackets to suit various applications including replacements * Insulation piercing connections on line and load sides * Insulated top mounting M8 shear head bolts * Underside entry cable connection ports creating drip loops on all installations * Accepts up to 0 amp BS style cartridge (58 x 22mm) * U.V. stabilised polymeric body with anti-flame retardant * Can be ganged to three phases using PFBKT3 or HFBKT3 * U.V. stabilised bird guards over cable seals * Completely waterproof bi-metallic connections. * Stainless steel mounting bolt * IP44 rated Testing Specification: Relevant sections of AS/NZS Salt fog tracking tests Additional temperature rise tests on service cables not specified in the standard Installation Notes: Use only a 3mm AF, six point hexagon socket to tighten bolts. Do not install old copper cables when corrosion may exist. All other connections made on the service or consumers cable must also be waterproof to prevent moisture ingress through the cable into the fuse holder. Product PFV0 PFV0KIT PFV0 695 Product PFV0 Fuse Disconnector 0 amp BS style (58 x 22) Fuse - 0 amp BS style includes PFVAB adaptor bracket installed Fuse Disconnector 0 amp BS style (58 x 22) ACCESSORIES Cable Range (mm 2 ) Pack 6 to to to 95 Pack PFBKT Pole bracket single phase 20 PFBKT3 Pole bracket three phase 5 HFBKT House bracket single phase 20 HFBKT3 House bracket three phase 5 PFVAB Adaptor bracket to fit PFV0 to swan neck pin FUSE BS0 0 amp BS Cartridge (58x22mm) 40 MOUNTING BRACKET OPTIONS HFBKT3 3 phase wall mount bracket PFBKT phase pole mount bracket PFBKT3 3 phase pole mount bracket HFBKT phase wall mount bracket PFVAB PFV0KIT Recommended tool for PFV0: RPS3/7-6H or RPS3/7-6SH

14 PRE-INSULATED FITTINGS MJPB and MJPT Series C Pre-insulated compression sleeves for joining LVABC services and mains. MJPB SERIES * Non-tension 4 to 35mm 2 range * Suitable for copper or aluminium MJPT SERIES * Limited and full tension 25 to 50mm 2 range * Suitable for copper or aluminium Product Service Cable (mm 2 ) Hex Die A/F Pack Product Mains Cable (mm 2 ) Hex Die A/F Pack MJPB MJPT MJPB MJPB MJPB MJPB 4 MJPB MJPB6-6 4 MJPB MJPB MJPB MJPB MJPB MJPB MJPB MJPB MJPB MJPB Crimp width: 9 mm Standard pack size: pcs MJPT MJPT MJPT MJPT MJPT MJPT MJPT MJPT **MJPT MJPT MJPT **MJPT ** Limited tension fittings When tested to AS3766, test load achieved is:- MJPT95SF: 7kN, MJPT95-2SF: 6.8kN All crimps 9mm in width Standard pack size: pcs MJPB Recommended tool for MJPB connectors: MP- SIMPI MJPT Recommended tool for MJPT connectors: Use any mechanical or hydraulic action crimp tool capable of accepting 9mm wide hexagonal crimp dies, with an across flats (AF) as specified in chart above. Minimum tonnage at die face recommended at 5 tonne. MP- SIMPI

15 PRE-INSULATED FITTINGS Pre-crimped sleeve & tools C2 Pre-insulated compression sleeves with pre-crimped, PVC insulated copper tails MJPB SERIES PRE-CRIMPED * Non-tension 4 to 35mm 2 range * Suitable for copper or aluminium Service Cable Copper or Aluminium (mm 2 ) Pre-crimped PVC insulated copper tail (mm 2 ) Insulation Ribs Length Hex Die AF Pack MJPB25-+CABLE 25 None MJPB25-+(N)CABLE 25 rib for neutral identification MJPB25-6+CABLE 25 6 None MJPB25-6+(N)CABLE 25 6 rib for neutral identification Crimp width: 9mm for all products Recommended tool for all products: MP- SIMPI APPLICATION TOOLING : MP- SIMPI * One-hand operation * Specifically designed for MJPB series and other pre-insulated products * Captive dies * Non-hydraulic * Hexagonal crimp AF: 4mm * Hexagonal crimp width: 9mm MP- SIMPI

16 PRE-INSULATED FITTINGS Pre-crimped sleeve & tools C3 MEPCNA SERIES * Pre-crimped with bare aluminium tail * End cap on tail provided to prevent fraying * Used for terminating LVABC into switchgear * Used for connecting LVABC to open wire bare conductor Product Cable (mm 2 ) Aluminium Tail (mm 2 ) Die A/F Crimp Width MEPCNA MEPCNA MEPCNA MEPCNA MEPCNA MEPCNA MEPCNA MEPCNA95* MEPCNA50* * 75 deg C current rating: 250A Pack 0 0 MEPCNA MEPCNU SERIES * Pre-crimped with bare copper tail * End cap on tail provided to prevent fraying * Used for terminating LVABC into switchgear * Used for connecting LVABC to open wire bare conductor Product Cable (mm 2 ) Copper Tail (mm 2 ) Die A/F Crimp Width MEPCNU MEPCNU MEPCNU MEPCNU MEPCNU MEPCNU MEPCNU MEPCNU95* MEPCNU50** *75 Deg C current rating: 250A **75 Dec C current rating: 370A Pack MEPCNU Recommended tool for MEPCNU6, MEPCNA6, MEPCNU25, MEPCNA25: MP- SIMPI. All other MEPCN series products: Any compression tool with min 5t output fitted with hexagonal compression dies as specified above. MP- SIMPI

17 PRE-INSULATED FITTINGS CPTAU and CPTA Series C4 A complete range of pre-insulated bi-metal and aluminium lugs for the termination of LVABC. CPTAU SERIES BI-METALS * Suits aluminium LVABC and other insulated compacted aluminium cables * Round copper palm * Suitable for connecting aluminium cables to switchgear, bus bars etc. L Product Cable (mm 2 ) Overall Length (L) Lug Dimensions Palm Hole Outside Palm Diameter Hex Die A/F Die Width CPTAU M CPTAU M CPTAU M CPTAU25-2.5DIA M CPTAU M CPTAU M CPTAU M CPTAU M CPTAU M CPTAU M Pack (pcs) Recommended tool for up to 25 mm 2 : MP- SIMPI, larger sizes: any compression tool with min 5t output fitted with hexagonal compression dies as specified above. CPTA SERIES ALUMINIUM *Suits aluminium LVABC and other insulated compacted aluminium cables * Square aluminium palm * Suitable for connecting aluminium cables to switchgear, bus bars etc. D W Product Cable (mm 2 ) Lug Dimensions Overall Length (L) Palm Hole Palm (W x D) Hex Die A/F Die Width CPTA M2 32 x CPTA35 35 M6 32 x CPTA50 50 M6 32 x CPTA95 95 M6 32 x CPTA M6 37 x Pack (pcs) L Recommended tool for up to 25 mm 2 : MP- SIMPI, larger sizes: any compression tool with min 5t output fitted with hexagonal compression dies as specified above.

18 UNDERGROUND CONNECTIONS MUCI Series D Multi-tap insulation piercing connectors for underground connection of two, three or four insulated cables. MUCI SERIES SUBMERSIBLE CONNECTORS Application: For the waterproof, underground connection of 2, 3 or 4 cables. Suitable for copper or aluminium insulated cables, single or double insulated from 6 to 50 sq mm. Ideal for connecting cables in pillar boxes, buried connection pits and streetlight columns. Features: * Fully submersible and totally waterproof. * Torque controlling shear head bolts for correct contact pressure. * Insulation piercing on all cable taps. * No need to strip cable. * Flexible sealing cable ports that are not affected by the angle of cable entry. * Fitted with push-on protective bolt caps. * IP67 rated Product of Connection Ports Conductor (mm 2 ) Bolt Head MUCI4/ to 50 3 MUCI3/ to 50 3 MUCI2/ to 50 3 MUCIBOLTYEL- LOW 3-7 (spare yellow shear head bolt) MUCI/H N/A N/A 3 Pack (pcs) 2 Gripping handle for MUCI4/650 & MUCI2/ Testing Specifications: Tested to ANSI C Tested to URD Pit Connector Technical Specification (Vic). Application Notes: MUCI4/650 Use only a 3mm AF, six point hexagon socket to tighten bolts. All other connections made on cables connected with this product must also be waterproof to prevent moisture ingress through the cable into the connector. MUCI3/ sq mm SDI may require the removal of the outer sheath, depending on insulation thickness and conductor compaction. The port sealing cap should be left in place when connecting 6 sq mm cables and removed for larger sizes Cables less than 6 sq mm may be connected by doubling over the last 2cm of cable prior to insertion. The port sealing cap should also be left in place. MUCI2/650 Each cable port should be only used twice. The blue bolt must be replaced with a yellow bolt to identify the second use of a cable port. MUCIBOLTYELLOW 3-7 MUCI/H Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

19 UNDERGROUND CONNECTIONS Resin Filled Service Tee Joint D2 PRODUCT NUMBER: HSM 270/40 RESIN FILLED TEE JOINT HSM 270/40 Application: For the waterproof, underground connection of low voltage services to low voltage mains distributor cables. Features: Easy to apply ring style connector Suitable for copper or aluminium cables Compact, low volume joint Suitable for direct burying Safe, mix in the bag two part resin No special tools required Suitable for a wide range of popular cable types Supplied complete with all necessary components for one complete Tee Joint Kit Components: Multi-phase ring connector Clear plastic encapsulating shell Encapsulating shell sealing kit Double chamber, mix in the bag resin system ( bag) Protective mixing gloves and cloth Abrading paper Installation instructions Testing Specifications: To international standards FULL SPECIFICATIONS, TEST REPORTS AND INSTALLTION INSTRUCTIONS ARE AVAILABLE ON REQUEST Sealing kit Ring Connector Specifications - ring connector Specification Acceptable mains cables; -Aluminium 4 core XLPE/PVC solid sector -Aluminium 4 core XLPE/PVC stranded sector (not suitable for 3 core sector cables) Acceptable service (branch) cables; Copper or aluminium 4 core circular stranded:- -Single service or branch -Double service or branch Mains cable contact screw tightening torque Service cable screw tightening torque Tool required for tightening contact screws Specifications - Completed Joint Specification Overall dimensions of completed joint, excluding cables Weight (with resin, excluding cables) Maximum overall diameter of main cable Maximum overall diameter of service cable Maximum number of service cables Volume of resin required Waste disposal Recommended tools Value 95 (min) 240 (max) mm 2 95 (min) 85 (max) mm 2 6 (min) 95 (max) mm 2 6 (min) 25 (max) mm 2 20 Nm 4 Nm 5mm AF hexagonal allen key or T handled box wrench. TBOX 5MM Value 305mm (length) 40mm (width at widest point) 85mm (height) 4.7 kg 54mm 40mm Two 4 core cables 3 litres (nominal) Waste packaging may be disposed of as normal landfill. Mix in the bag resin system TBOX 5MM JTN/2 core separator

20 UNDERGROUND CONNECTIONS BF-A and TF-2A Series D3 Mechanical connectors for use on sector shaped U/G cables. BF & TF SERIES BI-FORM AND TRI- FORM MECHANICAL CONNECTORS: * Accepts 85 and 240mm² 4 core solid or stranded aluminium sector cables to AS25. * Accepts up to two 50mm² copper tap-off connections. (3 for TF-2A connector) * Available in BI-FORM or TRI-FORM form which allows either two sector cable connections (normal loop type pillar) or three connections (three way loop pillar). * Shear-head screw on main cable connections provide correct tightening of bolts and ensure trouble free operation. * No special tools needed for installation, just a spanner! * Compact dimensions allow standard protective covers to be used. * Fully tested to standard BS4579 Specification for performance or mechanical and compression joints in electric cable and wire connectors (2000 heat cycles). Product Connections Mains Tap BF-A 2 2 BF-A/SYD 2 2 TF-2A 3 3 TF-2A/SYD 3 3 TF-2A/SYD Main Cable Range 20 solid Al. 20 stranded Al. 240 solid Al. 240 stranded Al. 20 solid Al. 20 stranded Al. 240 solid Al. 240 stranded Al. 20 solid Al. 20 stranded Al. 240 solid Al. 240 stranded Al. 20 solid Al. 20 stranded Al. 240 solid Al. 240 stranded Al. Maximum Tap 2 x 50mm² Cu. 2 x 50mm² Cu. 3 x 50mm² Cu. 3 x 50mm² Cu. Service Tap Stud Pack BF-A/SYD

21 UNDERGROUND CONNECTIONS Mechanical Connectors D4 BST/A SERIES Application: Branch connections to mains cables Conductor Type: 3 or 4 core solid sector aluminium Hexagonal head screw available as an option. Add suffix H to product number. Eg BST/A3H Branch Conductor (mm 2 ) s: Mains conductor size (mm 2 ) BSTA/ All connectors BST/A2, BSTA/3 The combinations in the table above are valid for conductors of the same sector shape, i.e. 4 core to 4 core, or 3 core to 3 core. Should mixed combinations be required, we suggest that verification of the products suitability be obtained prior to use. Packed individually in plastic bags 3/6 AF hex drive required LVM SERIES Application: General purpose branch or service connections. Conductor Types: Most conductor types including solid or stranded, circular or shaped, copper or aluminium. Stranded service conductors of 6 mm 2 or below should be doubled and re-doubled where necessary to achieve a satisfactory cross sectional area. Conductor Range (mm2) Mains / Service Mains / Branch / Service Overall Length (A) Width (B) LVM LVM LVM All connectors are electro-tinned. Brass gauze is not necessary for copper conductors LVM3 Shear head caps are available as an option. Packed individually in plastic bags

22 UNDERGROUND CONNECTIONS Mechanical Connectors D5 MF SERIES Application: Straight through joint for 3 or 4 core sector shaped solid or stranded aluminium, and stranded copper conductors. Features: All connectors feature a shear head bolt for bolting torque control. Pressure pads are included for stranded conductor connectors. MF and MF3 types are supplied with brass gauze for connection of copper conductors. When connecting copper conductor, the brass gauze supplied with connector should be wrapped around the copper conductor prior to bolting. MF3 type connectors include pressure pad for stranded side only. Packed individually in sealed plastic bags Product Conductor Range (mm 2 ) Overall Length (A) Width (B) x Height (C) Hex Head AF Pack Connectors for joining STRANDED sector to STRANDED sector shaped conductors MF/ x25 3 MF/ x33 7 MF/ x4 7 MF/ x5 9 MF/3A x4 7 MF/3G only 20 40x4 7 MF/3H only 20 40x4 7 Connectors for joining SOLID sector to SOLID sector shaped conductors MF2/* x25 3 MF2/2* x33 7 MF2/3* x4 7 Connectors for joining STRANDED sector to SOLID sector shaped conductors, in either orientation MF3/ x25 3 MF3/ x33 7 MF3/ x4 7 MF3/3A stranded solid 20 40x4 7 MF3/3D 240 only 20 40x4 7 * MF2 types not supplied with brass gauze. MF Type Connector Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH MF3 Type Connector

23 UNDERGROUND CONNECTIONS Mechanical Connectors D6 UM SERIES Application: Straight-through joint for 3 or 4 core sector shaped solid or stranded aluminium, and stranded copper conductors. Features: The UM series feature a removable bridge, allowing the conductor to be easily positioned into the connector. All connectors feature a shear-head bolt for bolting torque control. Pressure pads are included for connecting stranded conductors and should be discarded when connecting solid core conductors. All UM series connectors are supplied with brass gauze for connection of copper conductors. When connecting copper conductor, the brass gauze supplied with connector should be wrapped around the copper conductor prior to bolting. Conductor Range (mm 2 ) Overall Length (B) Width (A) x Height (C) Hex Head AF Application range for STRANDED 3 or 4 core sector shaped aluminium conductors UM x32 7 UM x36 7 UM x45 7 UM x40 7 Application range for SOLID 3 or 4 core sector shaped aluminium conductors UM x32 7 UM (3 core) (4 core) 0 3x36 7 UM x45 7 UM x40 7 Application range for STRANDED circular copper or aluminium conductors UM x32 7 UM x36 7 UM x45 7 UM x40 7 All connectors in the series are supplied with brass gauze Pack Packed individually in sealed plastic bags Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

24 UNDERGROUND CONNECTIONS Mechanical Connectors D7 MF5 SERIES CONNECTORS WITH CENTRE BARRIER Application: Straight-through jointing of stranded or solid, circular or sector shaped copper or aluminium conductors. The circular profile of the connector makes them especially suited to kv & 22kV cable joints. Features: The MF5 series of bolted connectors feature an integral centre moisture barrier and utilises the patented universal range taking shear-head bolts. The connector is shipped complete with core stripping guides and brass gauze for the jointing copper conductors. When using these connectors in HV joints, it is essential that the jointing system supplier s instructions for stress relieving and re-insulation techniques are strictly adhered to. Packed individually in sealed plastic bags Test Specifications: ER C79 IEC 238- AS/NZS Product Conductor Range (mm 2 ) Overall Length (L) Diameter (ΦB) Bolt (ΦC) Application range for STRANDED SECTOR shaped conductors MF5/ 6 to M6 MF5/2 6 to M6 MF5/3 70 to M8 Application range for SOLID SECTOR shaped conductors MF5/ 6 to M6 MF5/2 6 to M6 MF5/3 70 to M8 Application range for STRANDED CIRCULAR conductors MF5/ 6 to M6 MF5/2 6 to M6 MF5/3 70 to M8 MF5/EDF 95 to M6 Application range for SOLID CIRCULAR conductors MF5/ 6 to M6 MF5/2 6 to M6 MF5/3 70 to M8 Pack Required tool for all products: JTS/6 Splined socket with RPS3/7-6H or RPS3/7-6SH. JTS/6 RPS3/7-6H

25 UNDERGROUND CONNECTIONS Mechanical Connectors D8 MF7 SERIES CONNECTORS WITHOUT CENTRE BARRIER Application: Straight-through jointing of stranded or solid, circular or sector shaped copper or aluminium conductors. The circular profile of the connector makes them especially suited to kv & 22kV cable joints. Features: The MF7 series bolted connectors utilise the patented universal range taking shear-head bolts and comes complete with core stripping guides. Supplied with brass gauze for the jointing of copper conductor. When using these connectors in HV joints, it is essential that the jointing system supplier s instructions for stress relieving and re-insulation techniques are strictly adhered to. Packed individually in sealed plastic bags Test Specifications: ER C79 IEC 238- AS/NZS Product Conductor Range (mm 2 ) Overall Length (L) Diameter (ΦB) Bolt (ΦC) Application range for STRANDED SECTOR shaped conductors MF7/ * to M6 MF7/2 6 to M6 MF7/3 70 to M8 MF7/4 85 to M8 Application range for SOLID SECTOR shaped conductors MF7/ to M6 MF7/2 6 to M6 MF7/3 70 to M8 MF7/4 85 to M8 Application range for STRANDED CIRCULAR conductors MF7/ * to M6 MF7/2 6 to M6 MF7/3 70 to M8 MF7/4 85 to M8 Application range for SOLID CIRCULAR conductors MF7/ to M6 MF7/2 6 to M6 MF7/3 70 to M8 MF7/4 85 to M8 Pack *Conductor cores sq mm and below should be doubled to achieve necessary cross sectional area. Required tool for all products: JTS/6 Splined socket with RPS3/7-6H or RPS3/7-6SH. JTS/6 RPS3/7-6H

26 UNDERGROUND CONNECTIONS Mechanical Connectors D9 ML SERIES BOLTED LUGS Application: Termination of stranded or solid, circular or sector shaped, aluminium or copper cables. Features: * Shear-head bolts for torque control * No specialised compression tools required * Supplied with brass gauze for copper conductors Test Specifications: BS4579, including short circuit test ER C79 Product Conductor Range (mm 2 ) Stud (E) Overall Length (A) Palm Width (B) Barrel Height (C) ML-2 50 to 95 M ML-6 50 to 95 M ML to 85 M ML to 85 M ML to 300 M ML to 300 M ML4 400 to 500 M Hex head bolt AF is 7mm for all products. Pack Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

27 MAINS BRANCH CONNECTORS Mechanical Connectors D WB, 2 & 3 SERIES - Mains to Mains Branch Connectors Principal Applications Designed to accommodate three or four core sector shaped stranded conductors in the ranges specified in the table. Ease of fitting and simplicity of use were fundamental objectives adopted in the design of these connectors. The shear head screw principle ensures that a reliable and consistent connection is achieved without the need for specialised tooling. Each connector is supplied in a sealed pack together with fitting instructions, details of which are below. Principal Application Conductor Range (mm 2 ) 3 or 4 core stranded sector Main Branch Min. Max. Min. Max. Weight (g) WB WB * * 505 WB * Sector core dimensions to BS 679 only Secondary Applications These connectors can accept stranded circular conductors (copper or aluminium) in the main and/or branch sides of Secondary Application Conductor Range (mm 2 ) Stranded circular Main Branch Min. Max. Min. Max. WB WB WB Physical Dimensions For both principal and secondary applications. Material: Aluminium Alloy Dimensions A B C D WB WB WB Fitting Instructions - A 9mm AF hex socket is required Separate the main cable cores sufficiently to allow yoke section to be fitted around the conductor and strip the insulation from the core equal to the connector length plus mm. Thoroughly abrade the exposed conductor and loosely assemble the lower limb (mains side) of the connector around the core by fitting the bridge piece, inserting the pressure pad and tightening the mains screws until the connector is positively located. Set and locate the branch core, then cut to length, strip insulation to suit and thoroughly abrade the exposed conductor before assembling into the connector as described above. Complete the operation by tightening down the mains screws consecutively, one turn at a time, until both heads shear. Repeat the operation for the branch screws. If copper conductors are to be jointed, they should be wrapped in brass gauze in order to improve the electrical stability of the interface connection.

28 MAINS BRANCH CONNECTORS Mechanical Connectors D WB4 Mains Branch connector Principal application Primarily for four core sector shaped stranded cables, in both copper and aluminium. The branch channel designed to accept the branch conductor in any orientation to suit any particular joint configuration. Shear-head screws ensure that the correct clamping pressure is applied to give reliable connection, eliminating the need for the use of specialised tools on site. The connector is supplied individually packed, complete with fitting instructions, full details of which are below. Brass gauze can be supplied upon request for use with copper conductors. Principal Application Conductor Range (mm 2 ) Primarily for 4 core stranded sector Main Branch Min. Max. Min. Max. Weight (gms) WB Secondary Principal Suitable for stranded circular conductors. Physical Dimensions Material: Aluminium alloy Secondary Application Conductor Range (mm 2 ) Stranded circular Main Branch Min. Max. Min. Max. WB Fitting Instructions Separate the main cable cores to enable the main channel of the connector to be fitted around the conductor. Strip 70mm length of insulation (connector length plus mm) from the core at the selected connection position. Thoroughly abrade the exposed section of the conductor, pass the lower channel (mains side) of the connector yoke around the conductor and loosely assemble by inserting the pressure pad and bridge piece. Tighten the screws until the connector is positively located on the main but do not shear off the screw heads at this stage. Set the branch core and cut the required length. Strip the insulation to suit and thoroughly abrade the exposed conductor. Assemble as for the main connection. Complete the operation by tightening the mains screws consecutively, one quarter of a turn at a time, until both heads are sheared. Repeat the operation for the branch side. If copper conductors are to be jointed, they should be wrapped in brass gauze before insertion into yoke. Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

29 SERVICE BRANCH CONNECTORS Mechanical Connectors D2 WS2 - Mains to Service Branch Connector Principal Applications Designed to accommodate solid or stranded service conductors to a maximum of 95mm 2, from four core stranded sector shaped mains conductors in the range 20-85mm 2. The connector employs the proven shear-head screw principal to ensure that a consistent and reliable connection is achieved. Fitting is completed by the use of orthodox hand tools only. No specialised equipment or techniques are required. Each connector is supplied in a sealed pack together with fitting instructions, details of which are below. Principal Application Conductor Range (mm 2 ) Main 4 core stranded sector Branch Solid or Stranded Min. Max. Min. Max. WS * *Note - for small section conductors see fitting instructions below Weight (gms) Secondary Applications Can accept stranded circular conductors (copper & aluminium) in the main and/or branch sides of the connector. Physical Dimensions Material: Aluminium alloy. Secondary Application Conductor Range (mm 2 ) Stranded circular sector conductor Main Branch Min. Max. Min. Max. WS Fitting Instructions Separate the main cable cores sufficiently to allow the yoke section to be fitted around the conductor and strip the insulation from the core equal to the connector length plus mm. Thoroughly abrade the exposed conductor and loosely assemble the connector around the core by fitting the bridge piece, inserting the pressure pad and tightening the mains screw until the connector is positively located. Cut the branch conductor to length, strip the insulation to suit, then thoroughly abrade and assemble the core into the connector by fitting the bridge piece and pressure pad, and tightening down the service screws to hold the conductor in position. Complete the operation by tightening down the mains screws until the heads shears, then finally tightening the service screws consecutively, one turn at a time, until both heads are sheared. It is suggested that conductors below the minimum range requirement of 6mm 2 are doubled and, if needed, redoubled to achieve the required cross sectional area and, if copper conductors are to be jointed, they should be wrapped in brass gauze in order to improve the electrical stability of the interface connection. Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

30 SERVICE BRANCH CONNECTORS Mechanical Connectors D3 WS3 - Mains to Service Branch Connector Designed to accommodate solid or stranded service conductors to a maximum of 95mm 2, from four core stranded sector shaped mains conductors in the range 20-85mm 2. The connector employs the proven shear-head screw principal to ensure that a consistent and reliable connection is achieved. Fitting is completed by the use of orthodox hand tools only. No specialised equipment or techniques are required. Each connector is supplied in a sealed pack together with fitting instructions, details of which are included in the technical data below. Conductor Range (mm 2 ) Main 4 core stranded Branch Solid or stranded Min. Max. Min. Max. Weight (gms) WS * * Note - for small section conductors see fitting instructions below Material: Aluminium Alloy Physical Dimensions Dimensions A B C D E WS Fitting Instructions Separate the main cable cores sufficiently to allow the yoke section to be fitted around the conductor and strip the insulation from the core equal to the connector length plus mm. Thoroughly abrade the exposed conductor and loosely assemble the connector around the core fitting the bridge piece, inserting the pressure pad and tightening the mains screw until the connector is positively located. Cut the branch conductor to length, strip the insulation to suit, then thoroughly abrade and assemble the core into the connector by fitting the bridge piece and pressure pad, and tightening down the service screws to hold the conductor in position. Complete the operation by tightening down the mains screws until the heads shears, then finally tightening the service screws consecutively, one turn at a time, until both heads are sheared. It is suggested that conductors below the minimum range requirement of 6mm 2 are doubled and, if needed, redoubled to achieve the required cross section area and, if copper conductors are to be jointed, they should be wrapped in brass gauze in order to improve the electrical stability of the interface connection. Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

31 SERVICE BRANCH CONNECTORS Mechanical Connectors D4 WS4 - Mains to Service Branch Connector Principal Application Designed to accommodate a double service configuration to a maximum of two 95mm 2 stranded conductors, off four core stranded sector shaped mains conductors in the range mm 2. The connector employs the proven shear-head screw principal to ensure that a consistent and reliable connection is achieved. Fitting is completed by the use of orthodox hand tools only. No specialised equipment of techniques are required. Each connector is supplied in a sealed pack together with fitting instructions, details of which are included in the technical data below. WS4 Principal Application Conductor Range (mm 2 ) Main (4c sector stranded) Branch Min. Max. Min. Max x 50 (circ) 95 (sector) 2 x 95 (circ) 85 (sector) Weight (g) 260 Secondary Applications (a) Single Branch Connections WS4 connector is also suitable for single branch connections in the range 95-85mm 2 (sector shaped conductors). (b) Circular Conductors WS4 can accept stranded circular (aluminium or copper), in the mains and/ or branch sides. Material: Aluminium Alloy Secondary Application Conductor Range (mm 2 ) Main (Circular) WS Branch (Circular) Min. Max. Min. Max. x 50 or 2 x 50 x 50 or 2 x 70 Physical Dimensions Dimensions A B C D E WS Fitting Instructions Separate the main cable cores sufficiently to allow the yoke section to be fitted around the conductor and strip the insulation from the core equal to the connector length plus mm. Thoroughly abrade exposed conductor and loosely assemble the connection around the core by fitting the bridge piece, inserting the pressure pad and tightening the mains screw until the connector is positively located. Cut the branch conductor to length, strip the insulation to suit, then thoroughly abrade and assemble the core into the connector by fitting the bridge piece and pressure pad, and tightening down the service screws to hold the conductor in position. Complete the operation by tightening down the mains screws until the head shears, then finally tightening the service screws consecutively, one turn at a time, until both heads are sheared. If copper conductors are to be jointed, they should be wrapped in brass gauze in order to improve electrical stability of the interface connection. Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

32 SERVICE BRANCH CONNECTORS Mechanical Connectors D5 WS5 - Mains to Service Branch Connector Principal Application Designed to accommodate solid or stranded service conductors to a maximum of 95mm 2, from four core stranded sector shaped mains conductors in the range mm 2. The connector employs the proven shear-head screw principal to ensure that a consistent and reliable connection is achieved. Fitting is completed by the use of orthodox hand tools only. No specialised equipment or techniques are required. Each connector is supplied in a sealed pack together with fitting instructions, details of which are included in the technical data below. Secondary Application WS5 connector can accept stranded circular conductors (aluminium or copper) in the main and/ or branch sides of the connector. Material: Aluminium alloy Physical Dimensions Principal Application Conductor Range (mm 2 ) For solid or stranded sector Main (4c stranded sector) Branch (solid or stranded) Min. Max. Min. Max. Weight (g) WS * *Note - for small section conductors see fitting instructions below. Secondary Application Conductor Range (mm 2 ) Main (circular) Branch (circular) Min. Max. Min. Max. WS Dimensions A B C D E WS Fitting Instructions Separate the main cable cores sufficiently to allow the yoke section to be fitted around the conductor and strip the insulation from the core equal to the connection length plus mm. Thoroughly abrade expose conductor and loosely assemble the connector around the core by fitting the bridge piece, inserting the pressure pad and tightening the mains screw until the connector is positively located. Cut the branch conductor to length, strip the insulation to suit, then thoroughly abrade and assemble the core into the connector by fitting the bridge piece and pressure pad, and tightening down the service screws to hold the conductors in positions. Complete the operation by tightening down the mains screws until the head shears, then finally tightening the service screws consecutively, one turn at a time, until both heads are sheared. It is suggested that conductors below the minimum range requirement of 6mm 2 are doubled and, if needed, redoubled to achieve the required cross sectional area and, if copper conductor are to be jointed, they should be wrapped in brass gauze in order to improve the electrical stability of the interface connection. Recommended tool for all products: RPS3/7-6H or RPS3/7-6SH

33 PROTECTIVE COVERS D6 UGT Series Underground Warning Tapes Application: Suitable for use in conjunction with underground electrical services as a means of indicating its proximity. Features: Made from polyethylene Minimum 25mm print size on tape Colours comply with AS 2700 Testing Specifications: Manufactured and tested to the requirements of AS/NZS 4275:995. Product Type / Marking Colour Width Length (m) UGT-E Electrical ORANGE UGT-C Communications WHITE UGT-G Gas YELLOW UGT-E Pack Roll Roll Roll Overhead Line Covers (Tigertails ) Tested to comply with AS-4202, Class insulating covers Dimensions Length Diameter TIGER TAIL DB35A Linesman Safety Covers Tested to comply with AS-4202 Class 2 insulating material Dimensions Length Width LSC LSC LSC Underground Pit Connections Safety Cover Designed to fit into most commonly used distribution service pits. Provides an additional insulating barrier of safety for the pit connections if the main pit cover is removed or damaged. Provided with an eyelet for safe extraction by service personnel. Orange in colour, with Danger Electricity moulded into the unit. (Illustrative Only)

34 TOOLS AND ACCESSORIES Spanners, testers, wedges and allen key E These tools provide linesmen with a reliable means of installing all insulation piercing connectors. Product No: RPS3/7-6H The spanners have the following features: * 3mm across flats and 7mm across flats in one spanner. * Reversible ratchet. * Suits all sizes of insulation piercing connectors (TTD and NTD) for cables.5mm² up to 240mm², most strain clamps and some suspension clamps. * 6 point hex (double sided) * Overall length 267mm Product No: RPS3/7-6SH. Short handled version of above. Overall length 97mm. RPS3/7-6H Product No: PPI54 Re-usable insulated cable test point. Suitable for cable ranges up to 50mm². PPI54 Product No: CIE0 Core separation tool suitable for LVABC up to and including 4 x 95mm². CIE0 Product No: PMR87 Core separation wedge suitable for LVABC up to and including 4 x 95mm². PMR87 Product No: TBOX 5MM T handled 5mm allen key driver, insulated handle. Suitable for popular tee joint style ring connectors.

35 TOOLS AND ACCESSORIES Cutters, Strippers & Testers E2 Product No: TOOL BAG Linesman s plastic tool bag Product No: TBLVABC Linesman s LVABC tool kit. Includes tool bag, RPS3/7-6H, PPI54, CIE0, PMR87 (4) TOOL BAG TBLVABC Product No: RCC-42 ratchet cable cutter Conductor range: up to 4 x 95mm 2 LVABC Ideal for cutting bundled LVABC service and mains cables. Not suitable for high tensile steel. Product No: CES & CES2 Cable end seals. Easy push on cap providing complete waterproofing of cable ends. Only two sizes required to cover entire range of LVABC cables. Product Cable (mm²) Diameter of cable Length L CES 6 to to CES2 95 to to Pack Cable strippers Specially designed to strip LVABC Cable (mm²) CS CS50 50 Product No: VS-MS47VH Non contact audible, visual, vibrating voltage tester Vac Microwave leakage detection > 5mW/cm Includes 4 LR44 batteries

36 TOOLS AND ACCESSORIES Stringing Tools E3 Product No: 2870 Service Cable Come-along Conductor range: 2 x 6mm 2 to 4 x 35mm 2 Conductor Type: LVABC Max working load: 2kN Failing Load: 2.5kN Weight: 0.9kg Product No: 2887 Service/Mains Cable Come-along Conductor range: 2* x 25mm 2 to 4 x 95mm 2 Conductor Type: LVABC Max working load: kn Weight: 2.kg *additional sleeving may be required for some 2 core cables Product No: SCBT38 Mains cable come-along Conductor range: 4 x 95mm 2 Conductor type: LVABC Max working load: 8kN Failing Load: 25kN Weight: 3.8kg Product No: BCCA Mains cable come-along Conductor range: 4x95mm 2 to 4 x 50mm 2 Conductor type: Bundled LVABC Max working load: Failing Load: Weight: 6.3kg Product No: MR534 Mains cable come-along Conductor range: 4 x 95mm 2 Conductor type: LVABC Max working load: 20kN Failing Load: 32kN Weight: 5.0kg Product No: 5340 Mains cable come-along Conductor range: 4 x 25mm 2 to 4 x 50mm 2 Conductor type: LVABC Max working load: 20kN Failing Load: 35kN Weight: 5.0kg Product No: Mains cable come-along Conductor range: 2 x 25mm 2 to 2 x 95mm 2 Conductor type: LVABC Max working load: 29kN Failing Load: 46kN Weight: 2.3kg

37 TOOLS AND ACCESSORIES Stringing Tools E4 Product No: GRIP Service line tensioner Max working load: kn Failing Load: 5kN Weight:.4kg Ideal for hand stringing overhead service conductors and other light pulling work. Use in conjunction with comealong product number Product No: PST Service tensioner Product No: BR50-S Ratchet buckle and strap Safe working load: 2.6kN Product No: 6707BC Cable stringing block Working load: 34kg Weight: 4.5kg Sheave diameter: 78mm Groove diameter: 53mm Groove depth: 30mm For complete specifications and accessories, please call Sicame. Product No: TOOL-LUG-ALL 30A kg max capacity Step reverse feature Complete with bag Light weight: 4.5kg

38 CABLE JOINTING TOOLS JTN Tools E5 Insulated Core Wedge Designed to aid the separation of cores during jointing, these wedges are moulded in Nylon to resist detrimental wear at the tip during normal use. The thumb-and-finger grip assists insertion and removal, but it s small enough not to obstruct work on and around the joint. Overall Length Weight (g) JTN/ Insulated Core Separator & Wedge Ideal for 3 core sector cables when a standard wedge cannot be employed. Overall Length Weight (g) JTN/ Hepnyf Plastic Hack-Knife Developed for stripping the lead sheath and removal of the bedding compound from cable. A clean cut can be made without damage to the underlying insulation, allowing the sheath of live cables to be safely removed. The blade can be re-sharpened with a file. Overall length Depth of blade Weight (g) JTN/ : RIPPER - cable sheath remover The all metal, multi-grip handle can be gripped outside or inside, right & left hand. Cuts most plastic insulation cold. Apply heat and the toughest hardest plastic cuts like butter. Cuts any shape any direction, no limit to diameter or length. Blade can be sharpened or replaced. Replacement blades available. : ORB- - Oxide removal brush Painted black (for identification) for use on copper conductors to remove copper oxide film prior to crimping of cable lugs. : ORB-2 - Oxide removal brush Painted white (for identification) for use on aluminium conductors to remove aluminium oxide film prior to crimping of cable lugs. This is a safe and efficient method for removing oxide film from conductors

39 TOOLS AND ACCESSORIES Battery Powered Driver E6 Product No: SB-3UK battery powered impact socket driver Battery powered tool especially designed for use with shear head type bolts. Suitable for use on all Sicame products fitted with shear head bolts. The SB-3UK package contains: Battery powered impact driver () Nickel-metal hydride re-chargeable battery () Mains (240V) powered battery charger () 3mm AF, six sided /2 inch drive socket () 7mm AF, six sided /2 inch drive socket () Sturdy plastic carrying case and operating instructions Impact driver Impact Driver Specifications: Torque: 96 Nm Speed: 0-2,200 rpm Motor: 4.4 Vdc Socket drive: /2 square Dimensions: 350 (L) x 80 (H) x 75 (W) mm Weight: 2.5 kg (including battery) Battery Specifications: Output: 4.4 Vdc Capacity: 3 Amp Hour Life: 3000 charges (approx) Charge time: 40 mins with supplied charger Re-chargeable battery Charger Specifications: Input voltage: 240V Capacity: 230VA Equipped with various status indicating LED s Features: Fully insulated tool rated to 00V ac, 500 Vdc Unique shape to reduce its length for easy access in tight spaces. Variable speed Well balanced and lightweight Accepts any E-Robo series 4.4V battery 240 V battery charger Also available as an optional extra: 2Vdc powered battery charger for use in motor vehicles. Contact Sicame for details. Any other battery or powered driver must be referred to Sicame Australia for evaluation and approval prior to use on Sicame products.

40 MECHANICAL FITTINGS PA, PC AND BCST Series F PA & PC SERIES Wedge type strain clamps PA series for higher tensions. PC series for service tensions. PC series suitable for 2, 3 and 4 core twisted cables. Stainless steel bails on PA and PC models. Fibreglass reinforced UV stabilised nylon. Stainless steel bails Fibreglass reinforced UV stabilised nylon. Product PC63R22 PC63F27 PC63F27A PC63F27B Cable Type Neutral Screened Twisted or Flat Twisted or Flat Twisted or Flat Cable Diameter No. and of Cores (mm²) Min. Failing Load (kn) 4 to x 6 to 4 x x 6 to 4 x x 6 to 4 x Pack PA4 Twisted or Flat 2 x 6 to 2 x 25 6 PA5 Twisted or Flat 2 x 25 to 2 x 50 4 PA5D Twisted or Flat 2 x 6 to 4 x 25 2 PC63F27 PC63F27A PC63R22 PC63F27B PA4 PA5 PA5D BCST Series Bolted Type Service Strain Clamps Nylon glass reinforced clamping blocks Blocks spring loaded for ease of cable mounting Galvanised steel or plastic strap M stainless steel fastening hardware Can also be used as a suspension fitting by rotating the clamping blocks 90 degrees Cable (mm²) Strap Hook Style BCST G 2 x to 35 Galvanised Open BCST G 4 x to 35 Galvanised Open BCST P 2 x to 35 Nylon Open BCST PA 2 x to 35 Nylon Closed BCST P 4 x to 35 Nylon Open BCST PA 4 x to 35 Nylon Closed Pack BCST G BCST G BCST P BCST PA BCST P BCST PA

41 MECHANICAL FITTINGS SC and PA Series F2 Suspension clamps and termination clamps for ABC mains and sub-mains. SC SERIES SUSPENSION CLAMPS Application: Suspension of LVABC from 25mm 2 to 50mm 2 Product Dia. of circumscribing circle over laid-up cable cores Cable (mm²) 2 Core 3 Core 4 Core Features: SC to , 50 25, 35 * Suitable for angles up to 30º SC to * 30º to 60º use PSY/H bracket * Hinged aluminium alloy with body with stainless SC470 3 to steel fasteners SC to * Reinforced hanging eye to stop wear through vibration SC to * Large angle yokes available SC495 PSY/H Pack mm PA SERIES TERMINATION CLAMPS Application: Termination of LVABC 2 x 25mm 2 to 4 x 50mm 2 Features: * Bolted full tension clamp * Stainless steel fasteners available as an option * Meets requirements of AS3560 * Removable clevis pin Application Note: Use fillers if only 2 cores are utilised. PA22A Product PA2535 PA/ PA/S* PA/ PA/S* Cable (mm²) 2 x 25 to 50 and 4 x 25 to 50 2 x 25 to 50 and 4 x 25 to 50 2 x 50 to 95 and 4 x 50 to 95 2 x 50 to 95 and 4 x 50 to 95 Maximum Failing Load (kn) PA22A 4 x 95 to 4 x PA x 25 and 4 x 25 to 35 Rated Everyday Tension (kn) *Stainless steel fasteners Pack

42 HARDWARE OEB, JH and QH Series G OPEN EYE BOLTS TO AS3766 Length (L) mm 6mm Dia. (D) 20mm Dia. (D) OEB20X OEB6X250 * OEB20X250 * Pack 5 5 Thread Length 50mm OEB20X OEB6X OEB6X350 * OEB20X350 * 450 OEB6X450 * - * Preferred item in AS L Product No: J HOOK : M2 to AS3766 Packed in bags of 50 J HOOK Product No: J HOOK-T J Hook with earth tag : M2 to AS3766 Packed in bags of 50 J HOOK-T Product No: Q HOOK : M2 to AS 3766 Packed in bags of 50 Q HOOK Product No: HB Galvanised steel hook bracket. Max working load: 2kN Hook diameter: 6mm To AS mm Product No: ANG BKT To Energy Australia specifications

43 HARDWARE Weak links and eye nuts G2 Product No: OEN M2 M2 eye nut to Energy Australia specifications OEN M2 Product No: OEN M2 E M2 extended eye nut to Energy Australia specifications OEN M2 E Product No: LFG50.5kN weak link to Energy Australia specifications Packed in bags of 0 LFG50 ABC Mechanical Weak Link Can be installed between suspension clamp and pole support fitting. Can also be installed between service cable strain clamps or mains cable strain clamps. Mild steel galvanized to AS650. Colour coded Nominal Failing Load (kn) Dimensions D L M LFG400T LFG600T LFG800T LFG800T

44 TIME AND LIGHT CONTROLS H Locking -Type Photocontrols and Delayed Response Thermal Series Built-in time delay prevents false cycling caused by lightning flashes or stray headlights. Specifications Housing: UV stabilized high-impact polypropylene. Photocell: inch cadmium sulphide light sensitive element. Turn-on: to 3 foot-candles ( to 30 Lux) Turn-on/Turn-off Ratio: :3. Time Delay: Minimum 5 seconds. Switch Type: Single-pole, single-throw. Contact position at night normally closed. Temperature Range: -40 to 70 F. Power Consumption:. watts average at 20 VAC. Rated Life: 5,000 operations minimum at rated load. All products CSA Certified. Optional Surge Protection: Open Type (modified expulsion) 2.5 KV spark over minimum with 5,000 amps follow through. Add suffix LA. Enclosed Type (expulsion) 2.0 KV spark over minimum with,000 amps follow through. Add suffix ELA. MOV (Metal Oxide Varistor). 90 joule rating. Add suffix MOV M2AF Dimensions: 3.07 diameter, 2.5 high. Voltage Rating Specifications Surge Protection Lux rating P68275LA/ VA Open type 20 P68275LA/ VA Open Type 30 P68275MOV/ VA Metal oxide varistor 20 P VA None JP275 Accessories M2AF JP275 Receptacle for the above photocontrol units Low profile cover for receptacle. Shorts line to load, keeps lights ON at all times unless turned off from remote location. Other models and accessories are available. Contact Sicame for details.

45 Personal Safety J MO-00 Safety Glasses Stylish safety glasses made from tough polycarbonate, offering 98% UV protection. Adjustable sides. Delivered with pouch. Clear and tinted models available. MO-00 MO-0 Clear lenses, delivered in pouch Tinted lenses, delivered in pouch MO-0 MO- MO- Safety Over-glasses Safety glasses made from tough polycarbonate, offering 98% UV protection. Adjustable sides. Delivered with pouch. Clear and tinted models available. MO- MO- Clear lenses Tinted lenses MO-84 Helmet not included MO-86 Face Shield Protect yourself from short circuit arcs when working on switchboards; No metallic parts Adjustable Colourless.5mm anti-condensation, polycarbonate face shield Two models available, with Brow shield & Clip-on to hardhat. MO-84 MO-86 Clip onto helmet Brow Shield LED Headlamp Can be worn either on the head or any kind of helmet. Lighting by 3 high performance LED s. 3 lighting levels. Adjustable lamp height angle. Very light, waterproof IP65. Range: to 5 metres. Powered by 3 batteries LR03 (AAA). Battery life: 80 hours approx. MS-2 M Delivered with batteries & carry bag Weight: 0.09 Kg Hooks set for helmet

46 Personal Safety J2 00V Insulating Gloves Single Colour Tested to IEC Category M, Class 0 Made from mm thick specially treated latex Weight: 200g Available in 4 sizes Individually tested and shipped in a sealed plastic bag marked with test date CG--A 8 CG--B 9 CG--C CG--D Leather Overgloves Used as outer glove. Silicon grain leather, very supple. Large protective cuff in chrome tanned hide. Velcro strap. CG-98-A 8 CG-98-B 9 CG-98-C CG-98-D Leather Overgloves Used as outer glove. Silicon grain leather, very supple. Large protective cuff in chrome tanned hide. Velcro strap. Designed for use with >00V insulating gloves CG-99-A 8 CG-99-B 9 CG-99-C CG-99-D Cotton under-gloves To be used under insulating rubber gloves CG-80-H CG-80-F Men Women

47 Personal Safety J3 Rubber gloves storage box with window To be placed in high voltage sub-stations. Insulating material, shock resistant, yellow colour. Transparent window (ability to check gloves presence). Bottle of talc included. Attachment: 4 holes 3.5mm dia., centre distances 55x345mm. U.V. protective window. Overall length Weight (g) CG-35/ 60 x 2 x Carry bag Made from reinforced waterproof fabric for transport of rubber gloves in vehicles and tool boxes. Rear loop for belt and snaps. Overall length Weight (g) CG x 80 x Insulating mats The matting is manufactured of elastomer compounds with slip-resistant surface. High quality dielectrical rubber. Tested to IEC-6. Thickness Class MP-42/ 3 3 MP-42/6 3 3 Voltage (kv) Dimensions x 0.6 x Bags for insulating mats Especially designed for carrying and protecting insulating mats. Equipped with a shoulder strap and a plastic window for instructions and storage identification. Length (cm) MP-0 For MP-42/6 and MP-42/66 70 MP-02 For MP-42/

48 IEC TESTED 00V INSULATED TOOLS J4 IEC requires that all tools comply with various dimensional standards, to ensure that the tools meet important ergonomic design principles and are safe and easy to use. (Clause 5.3) DIMENSIONS IMPACT Each type of tool is subjected to an impact test to ensure the insulation can withstand normal daily wear and tear without serious damage. Impact tests are carried out at ambient, low and extremely low temperatures. (Clause 5.4) The dielectric test proves the integrity and performance of the tool s insulation. After conditioning in a water bath or wet chamber for 24 hrs, kv is applied for 3 minutes to the tool whilst it DIELECTRIC STRENGTH is immersed. The leakage current is measured and checked for compliance, the value of which depends on the type and size of tool. (Clause 5.5) INDENTATION An indentation test is carried out to ensure the tool s insulating properties are retained after being subjected to a point impact. After the impact, the insulation must withstand 5kV for 3 minutes without puncture, sparkover or flashover. (Clause 5.6) The adhesion test ensures that the tool s insulating coat will not slip, move or separate from the metal parts of the tool. After conditioning at 70 deg C for 68 hours, the tool is allowed to cool to an ambient temperature, then various forces are applied to test the adhesion properties and performance. (Clause 5.7) ADHESION Each type of tool is subjected to mechanical tests to ensure compliance with various ISO or national standards and to ensure the tool has the necessary mechanical strength for its intended application. MECHANICAL Orange, flame retardant PVC insulating outer layer with anti-slip treatment. Tough, impact resistant, white inner insulating layer, bonded to metal Primary adhesive layer Finger guard bonded to tool as part of the inner insulation layer

49 00V Insulated Tools J5 Insulated phase tester screwdriver Phase detection from 27V. Maximum voltage 00V. Signalling by intermittent lighting through ultra high intensity diode. Works with an un-removable lithium battery. 3 year battery life Weight (g) MO Flat blade 4 x 85mm 65 Flat blade screwdrivers Chrome - molybdenum vanadium steel blade Weight (g) MO mm blade x 0mm 33 MO mm blade x 0mm 37 MO mm blade x 0mm 46 MO mm blade x 25mm 75 MO mm blade x 50mm 94 MO mm blade x 75mm 65 MO-652 mm blade x 200mm 95 Pozidriv screwdrivers Chrome - molybdenum vanadium steel blade Weight (g) MO mm N o 0 head x 60mm 25 MO mm N o head x 80mm 50 MO mm N o 2 head x 0mm 75 MO mm N o 3 head x 50mm 50 MO mm N o 4 head x 200mm 230 Phillips screwdrivers Chrome - molybdenum vanadium steel blade Weight (g) MO mm N o 0 head x 60mm 25 MO mm N o head x 80mm 50 MO mm N o 2 head x 0mm 75 MO mm N o 3 head x 50mm 50 MO mm N o 4 head x 200mm 230

50 00V Insulated Tools J6 Universal pliers Special tool steel, oil hardened. Burnished head Overall length Weight (g) MO MO MO MO-66005* * For steel armoured cable Flat nose pliers Special tool steel, oil hardened. Burnished head Overall length Weight (g) MO MO Round nose pliers Special tool steel, oil hardened. Burnished head Overall length Weight (g) MO Bent snipe nose pliers Chrome-vanadium steel. Burnished head Overall length Weight (g) MO MO

51 00V Insulated Tools J7 Long nose pliers with side cutter Special tool steel, oil hardened. Burnished head Overall length Weight (g) MO Plug pliers for pre-insulated pin terminals Chrome-vanadium steel for 2.8, 5, 6.35mm pin terminals. Overall length Weight (g) MO Waterpump pliers Chrome-vanadium steel. Burnished head Overall length Weight (g) MO Standard type Overall length Weight (g) MO Box joint pliers Side cutters Special carbon steel. Oil hardened. Burnished head. Overall length Cutting capacity Weight (g) Soft 80Kg/mm 2 Hard 40Kg/ mm 2 MO Ø 2 Ø 50 MO Ø 2.5 Ø.5 80 MO Ø 3 Ø 2.5 2

52 00V Insulated Tools J8 End cutting pliers Special carbon steel. Oil hardened. Burnished head. Cutting capacity Overall length Weight (g) Soft 80Kg/mm 2 Hard 40Kg/mm 2 MO Ø Ø 2 65 MO Ø 2 Ø 3 2 MO Ø 3 Ø MO-6740, MO MO Cable cutter Chrome-vanadium. Forged steel. Overall length Cutting capacity Weight (g) MO Maximum Ø Cable cutters Chrome-vanadium. Forged steel. Oil-hardened. Overall length Cutting capacity Weight (g) MO Maximum Ø MO Maximum Ø MO-6750 MO Ratchet cable cutters For copper and aluminium cables only. Treated forged steel blade. Cutting capacity (max) Weight (g) MO Ø 32mm/ 80mm 2 Cu 250mm 2 Al 900 MO Ø 38mm/ 240mm 2 Cu 300mm 2 Al 950 MO-6760 Ø 55mm/ 300mm 2 Cu 450mm 2 Al 975 MO MO-6760

53 00V Insulated Tools J9 Parrot beak style cable cutter For copper and aluminium only. Treated forged steel blade. Cutting capacity Weight (g) MO-676 Ø 24mm/ 50mm 2 Cu 80mm 2 Al 790 Hacksaw Protected hard forged steel. Two blade positions. Flushed and 90º cutting angle. Delivered with 2 blades. Blade length Overall length Weight (g) MO Stripping pliers for L.V. cables Aluminium casting plier. To strip L.V. twisted cables. Blade depth adjustable. For use on LVABC cable. Overall length Stripping capacity Weight (g) MO from 6 to 50mm Stripping pliers for L.V. cables Aluminium casting plier. To strip L.V. cables. Blade depth adjustable. For use on LVABC cable. Overall length Stripping capacity (mm 2 ) Weight (g) MO From 6 to MO From 50 to

54 00V Insulated Tools J Wire stripping pliers Chrome vanadium. Burnished head. Overall length Capacity (mm 2 ) Weight (g) MO to 70 Stripping knifes Delivered with pouch. Blade length Overall length Weight (g) MO (Straight) 90 MO (Curve) 90 Adjustable spanner Special tool steel. Oil hardened. Overall length Maximum capacity Weight (g) MO MO MO MO

55 00V Insulated Tools J Reversible hexagonal ratchet handle Special tool steel. Oil hardened. AF Weight (g) MO MO MO MO MO MO Combination wrench Special steel sockets. 4 hexagonal sockets Weight (g) AF s Length MO x50mm 260 MO x50mm 250 MO x50mm 260 Right angle hexagonal key wrench Chrome-vanadium steel. B Hexagonal head Weight (g) AF A B MO MO MO MO A MO MO MO

56 00V Insulated Tools J2 Open end spanners. Chrome-vanadium steel. AF Weight (g) MO MO MO MO MO MO MO MO MO MO MO MO AF Weight (g) MO MO MO MO MO MO MO MO MO MO MO MO Spanner Sets Weight (g) MO-68008/9 Open end spanner set including 8,,, 2, 3, 4, 7, 9mm AF spanners 685 Cranked ring wrench Chrome-vanadium steel. AF Weight (g) MO MO MO MO MO MO MO MO MO MO MO MO MO AF Weight (g) MO MO MO MO MO MO MO MO MO MO MO MO

57 00V Insulated Tools J3 Hexagonal spanner with T handle Chrome steel. Length 30mm AF Weight (g) MO MO MO /4 sockets wrench sets Chrome steel. Weight (g) MO-6983 Socket 3mm AF - /4 drive 45 MO-6937 Socket 7mm AF - 3/8 drive 60 MO Extension /4 AF x 3/8 drive 60 MO-6952 Reversible ratchet - /4 drive 200 MO-6983/ 7 Complete socket set in plastic box 230 x 70 x Weight (g) MO-698 Socket mm - /4 35 MO-6983 Socket 3mm - /4 45 MO-6937 Socket 7mm - 3/8 60 MO Extension /4-3/8 60 MO-69840/7 MO-6952 Reversible ratchet - /4 200 MO-698/7 Complete socket set in plastic box 230 x 70 x Insulated Tool Kits For most common operations KIT 03 MO Pozidriv screwdriver* N o 4.5 x 80mm MO Pozidriv screwdriver* N o 2 6 x 0mm MO Flat blade screwdriver 3.5 x 0mm MO Flat blade screwdriver 5.5 x 25mm MO Flat blade screwdriver 8 x 75mm

58 00V Insulated Tools J4 3/8 & /2 drive sockets, sets and accessories Chrome steel. Sockets 3/8 drive - 6 sided Weight (g) MO mm AF socket 25 MO mm AF socket 30 MO-69308* 8mm AF socket 30 MO mm AF socket 30 MO-693* mm AF socket 35 MO-693 mm AF socket 35 MO-6932* 2mm AF socket 35 MO-6933* 3mm AF socket 45 MO-6934* 4mm AF socket 45 MO mm AF socket 50 MO mm AF socket 55 MO-6937* 7mm AF socket 60 MO mm AF socket 65 MO-6939* 9mm AF socket 70 MO-6932* 2mm AF socket 85 MO-69322* 22mm AF socket 90 MO mm AF socket 0 MO-6953* Reversible ratchet 600 MO-69523* 30mm extension 24 MO mm extension 270 MO mm T wrench 220 MO mm T wrench 380 MO-69308/ 23 Socket set comprising items marked * in plastic box 4 x 20 x Sockets /2 drive - 2 sided Weight (g) MO-69408* 8mm AF socket 60 MO-694* mm AF socket 60 MO-694 mm AF socket 60 MO-6942* 2mm AF socket 70 MO-6943* 3mm AF socket 70 MO-6944* 4mm AF socket 70 MO mm AF socket 75 MO mm AF socket 75 MO mm AF socket 80 MO mm AF socket 80 MO-6949* 9mm AF socket 85 MO mm AF socket 90 MO-6942* 2mm AF socket 0 MO-69422* 22mm AF socket 0 MO-69423* 23mm AF socket 5 MO mm AF socket 30 MO mm AF socket 60 MO-6954* Reversible ratchet 600 MO-69524* 25mm extension 250 MO mm T wrench 435 MO mm T wrench 520 MO-69408/ 23 * Sockets composing the sets Socket set comprising items marked * in plastic box 4 x 20 x * Sockets composing the sets MO MO MO-69308/23

59 00V Insulated Tools J5 Long series sockets, 3/8 drive Chrome steel. 65mm length AF Weight (g) MO MO MO MO MO MO MO MO U.S Standard sockets, 3/8 drive Chrome steel. AF Weight (g) MO /8 25 MO /6 30 MO /2 35 MO /6 35 MO /8 42 MO /6 50 MO /4 55 MO / sided male hex key socket, 3/8 drive Tool steel. AF Weight (g) MO MO MO MO MO MO Insulated torque wrench, 3/8 drive Capacity: 8 to 54 Nm (ibf Ft: 5-40). Length: 325mm Tolerance: 4% Weight (g) MO to 54 Nm 790

60 00V Insulated Tools J6 Contractors Tool bag Product No: M For intervention works Strong waterproof, canvas reinforced bottom Large capacity of storage with shoulder strap Contractors 00V Insulated Tool Kit Product No: TKC - 00V - Complete equipment requirements for level 2 service providers Tool bag included Tool kit comprises of the following items Personnel Equipment MO-0 pair safety glasses CG-98-* pair working gloves CG-80-H pair cotton under-gloves Insulating Gloves & Accessories CG--* pair 00v insulated gloves CG-36 carry bag for insulated gloves Insulated tools MO-60 stripping knife (curved blade) MO flat blade screwdriver 3x0mm MO flat blade screwdriver 5.5x25mm MO flat blade screwdriver 8x75mm MO phase tester screwdriver 4x85mm Tools Continue MO-6809 open ended spanner 9mm MO-683 ring spanner 3mm MO-687 ring spanner 7mm MO-689 ring spanner 9mm MO Adjustable wrench MO-6943 /2 drive-2 sided socket 3mm MO-6947 /2 drive-2 sided socket 7mm MO-6949 /2 drive-2 sided socket 9mm MO-6954 /2 reverse ratchet MO /2 25mm Ext bar * Gloves available in 4 sizes A=8, B=9, C= & D= MO Phillips screwdriver N 0 0 MO Phillips screwdriver N 0 2 MO Phillips screwdriver N 0 4 MO MO-662 MO-673 MO-6803 MO-6807 universal pliers 200mm long nose pliers 60mm side cutter 80mm open ended spanner 3mm open ended spanner 7mm

61 EARTH SYSTEMS Accessories K Clamp Removal Arm (Pigtail) Used for removing MT-63/3 snap-on clamps from overhead lines Available in 3 different fittings Normally sold with MT-630 clamp application platform (refer below) CRA/K CRA/S CRA/C CRA-C CRA-K CRA-S C - Hexagon fitting K - Universal fitting S - Shotgun fitting Clamp Application Platform Used for attaching MT-63/3 snap-on clamps onto overhead lines. Available in 3 different fittings Normally sold with CRA clamp removal arm (Pigtail). (see above) MT-630-C MT-630-K MT-630-S C - Hexagon fitting K - Universal fitting S - Shotgun fitting MT-630-C MT-630-K Fuse Remover Adaptor Used to remove drop-out fuses Available in 2 different fittings FRA-C FRA-C FRA-K C - Hexagon fitting K - Universal fitting FRA-K Drop-Out Fuse Earthing Adaptor Used for providing an earthing point on the bottom of drop out fuse carriers where conductors from drop out fuses to transformers are fully insulated. DOFEA Product No: DOFEA Link adaptor Used for attaching and removing drop-out fuses prior to applying a DOFEA. Available in 3 different fittings LKA/C LKA/C LKA/K C - Hexagon fitting K - Universal fitting LKA/S LKA/S S - Shotgun fitting LKA/K

62 EARTH SYSTEMS Accessories K2 Mines Discharge Sticks Used to discharge underground cables prior to being earthed. MDS/2 Mines Discharge Stick with Standard with 2 m lead Handle length: m MDS/2 EXT Mines Discharge Stick with Standard with 2 m lead & extended nipple Handle length: m MDS/2 Ext MDS/2 MDS/3 Mines Discharge Stick with Standard 3 m lead Handle length: m Modiwark Adaptor Used for holding Modiwark type voltage detectors on the end of a high voltage stick. Available in 4 different fittings MOD/C MOD/K MOD/S MOD/E MOD-C MOD-K MOD-S MOD-E C - Hexagon fitting K - Universal fitting S - Shotgun fitting E - Bayonet fitting Live Line Clamp Remover Fits onto a high voltage stick and is used for removing live line clamps. Available in 3 different fittings LLCR-C LLCR-K LLCR-S C - Hexagon fitting K - Universal fitting S - Shotgun fitting LLCR/K LLCR/C LLCR/S Service Fuse Puller Used for pulling services fuses on poles/houses. Available in 2 different fittings SFP-C SFP-K C - Hexagon fitting K - Universal fitting SFP/K SFP/C

63 EARTH SYSTEMS Accessories K3 Fixed Earth Connection Point An earthing point used in substations & switchrooms. Includes Bolts & Washers. Two diameters are available - 22mm and 25mm Rating (ka) Diameter Stub Diameter M2/22 BRS STUB 25kA/0.5 secs 2mm 22mm M2/25 BRS STUB 25kA/0.5 secs 2mm 25mm M6/22 BRS STUB 45kA/0.5 secs 6mm 22mm M2/22 BRS STUB M6/25 BRS STUB 45kA/0.5 secs 6mm 25mm Voltage Detector Extension Probe Extension probe which fits voltage detector type CC-875 for testing insulated switchgear. Product No: PROBE KSA/875 PROBE KSA/875 Length - 440mm Diameter - 20mm Manoeuvering Hook Bronze-Copper nickel aluminium Weight : 0.20Kg Available in two different fittings CM-02-C CM-02-K C - Hexagon fitting K - Universal fitting CM-02-C POLE SAFETY STEPS Safety pole steps with washer Product No: POLE SAFETY STEPS Equipment Boxes Ideal for storage & transport of high voltage detectors, accessories & other instruments. Watertight, shock & vibration proof and also dust proof Complete with foam inserts CASE EX LGE CASE LGE CASE MED Inside Dim 485x355x86mm Inside Dim 395x320x7mm Inside Dim 300x220x90mm

64 EARTH SYSTEMS Accessories K4 Connection adaptors for insulating sticks C K E S A or B Hexagonal Universal Bayonet Clamp - Stick MAJOR Serie CM-4/ CM-6/ CM-7 Accessories C K E Connection Adaptors CI-7-C CI-3-C CI-6-C CI-5-C CI-3-K CI-4-K CI-6-K CI-7-K CI-5-K CI-3-E CI-7-E CI-4-E Sticks E A B K S A B C K E S A B K C With this range, any accessory can be attached to any stick by using connection adaptors. For other models, please consult us. CI-6-C CI-4-E CI-7-E CI-4-K CI-5-C CI-7-K CI-5-C CI-3-C CI-7-C CI-5-K End Cap for CI-3-C CI-6-K

65 EARTH SYSTEMS Accessories K5 Clamp Application Handle Small PVC handle to apply Bayonet type earth clamps. HEC-250-E Length - 340mm Product No: HEC-250-E Stick Adaptor To connect Ergon sticks with hexagonal C fittings. CAPALEC ADAPTOR Length - 2mm Product No: CAPALEC ADAPTOR Stick Adaptor To connect Integral sticks to universal head tools or hexagonal C fittings. Available in 2 different fittings. P/N: IATH-K IATH-C IATH-K C - Hexagon fitting Length - 50mm K - Universal fitting Length - 200mm P/N: IATH-C Stick Adaptor To connect SECV/C sticks with hexagonal C fittings. SECV/C SECV to C adaptor Length - 230mm

66 EARTH SYSTEMS Accessories K6 Conductor Brushes Pivoting - 95 x 90 x 64mm Weight : 0.090Kg Universal head MG-206-AK MG-206-CK Moulded red colour body with card. Reserved for aluminium conductors Moulded red colour body with card. Reserved for copper conductors. Conductor Brushes Pivoting - x x 70mm Weight : 0.250Kg MG-354-K MG-352-K MG-352-VK MG-353-R MG-353-V MG-354-K MG-355 Moulded orange colour body with card. Reserved for aluminium conductors Moulded green colour body with card. Reserved for copper conductors. Orange spare brush for MG-353-K. For hand brushing use. Green spare brush for MG-353-K. For hand brushing use. Round brush - Ø 58 x 0mm Weight: Kg Spare brush for MG-354-K Diameter Measuring Gauge Conductor range 3 to 6mm Ø. Entirely insulated material 270 x 35 x 2mm Weight: Kg Rising Sun fitting Delivered in bag MD-535-K Cleaning Brushes Hex fitting MD-4-C MD--C MD-2-C MD-4-C Concave brush with two rows of perpendicular bristles 0 x 25 x 70mm - Weight: 0.500Kg Round head brush Ø 75 x 228mm - Weight: 0.500Kg Adjustable hinged round head brush Ø 75 x 328mm - Weight: 0.500Kg MD-2-C MD--C

67 EARTH SYSTEMS Clamps K7 Application Handle Used to tighten MT-85-S clamps onto earth connections. 85S/H Handle Length - 320mm Hand Applied Earth Clamps For connection of MT-92-E clamps to fixed earthing points. MT-92E H Earth Clamp with PVC Handle Length - 350mm P/N: MT-92E H Fixed Points Used for providing earthing points in substations/ switchrooms and flat conductors Commonly used with MT-92-E earth clamps (refer to above) Product Rating (ka) Sphere Dimension Weight (g) Fixing MT kA/0.5 sec Ø 25mm 240 Thread: M2 MT kA/0.5 sec Ø 25mm 240 Thread: M6 MT-395/ Ø 25mm 300 Bolt: M2 - L = 45mm MT-3952/ Ø 25mm 350 Bolt: M6 - L = 45mm MT-3950/35* Ø 25mm 300 Bolt: M6 - L = 35mm * = Not IEC P/N: MT-3950/35 P/N: MT-395 MT-3952 P/N: MT-395/ MT-3952/

68 CARRY BAGS Earths Set & Stick Bags K8 Earth Set Carry Bags ARB/500 BAG PVC ARB/454 Carry Bag 400 x 500 x Zipper BAG PVC ARB/500 Carry Bag 500 x 500 x 50 BAG PVC ARB/50 Carry Bag 500 x 500 x 50 + Divider BAG PVC ARB/502 Carry Bag 500 x 500 x Divider BAG PVC ARB/600 Carry Bag 600 x 600 x 50 BAG PVC ARB/60 Carry Bag 600 x 600 x 50 + Divider BAG PVC ARB/602 Carry Bag 600 x 600 x Divider BAG PVC ARB/700 Carry Bag 700 x 700 x 200 BAG PVC ARB/762 Carry Bag 700 x 600 x Zipper Stick Carry Bags ARB/S5 ARB/S45 BAG PVC ARB/MDS BAG PVC ARB/S BAG PVC ARB/S5 BAG PVC ARB/S20 BAG PVC ARB/S25 BAG PVC ARB/S30 BAG PVC ARB/S2 BAG PVC ARB/S25 BAG PVC ARB/S220 BAG PVC ARB/S3 BAG PVC ARB/S35 BAG PVC ARB/S320 BAG PVC ARB/S4 BAG PVC ARB/S45 BAG PVC ARB/S420 BAG PVC ARB/S5 BAG PVC ARB/S55 BAG PVC ARB/520 BAG Extra Pockets AES-MDS Stick Carry Bag x.0 Mt Stick Carry Bag x.5 Mt Stick Carry Bag x 2.0 Mt Stick Carry Bag x 2.5 Mt Stick Carry Bag x 3.0 Mt Stick Carry Bag 2 x.0 Mt Stick Carry Bag 2 x.5 Mt Stick Carry Bag 2 x 2.0 Mt Stick Carry Bag 3 x.0 Mt Stick Carry Bag 3 x.5 Mt Stick Carry Bag 3 x 2.0 Mt Stick Carry Bag 4 x.0 Mt Stick Carry Bag 4 x.5 Mt Stick Carry Bag 4 x 2.0 Mt Stick Carry Bag 5 x.0 Mt Stick Carry Bag 5 x.5 Mt Stick Carry Bag 5 x 2.0 Mt Stick Carry Bag Extra Pockets /P or /A for Adaptors etc..

69 LANYARDS & SANDBAGS K9 Lanyard for MT-70/ Clamps 8mm Megalon insulated Used for applying CATU clamp MT-70/ onto overhead wires. Length (Mt) LANYARD 08M 8 LANYARD 09M 9 LANYARD M LANYARD M LANYARD 2M 2 LANYARD 3M 3 LANYARD 4M 4 LANYARD 5M 5 LANYARD 6M 6 LANYARD 7M 7 LANYARD 8M 8 LANYARD 9M 9 LANYARD 20M 20 LANYARD 2M 2 LANYARD 22M 22 LANYARD 23M 23 LANYARD 24M 24 LANYARD 25M 25 LANYARD 30M 30 LANYARD 35M 35 LANYARD 40M 40 LANYARD 45M 45 LANYARD 50M 50 Sandbags Used with Megalon lanyards (see above) to hoist MT-70/ clamps onto conductors. Link SANDBAG ASSEMBLY SANDBAG W/LOOP Sandbag with link & sister clip Bag with sand & carry loop Sister clip P/N: SANDBAG ASSEMBLY P/N: SAND W/LOOP

KRONE KGH Series Fuse-Switch-Disconnectors. For Low Voltage ABC Systems or Open-wire Overhead Networks

KRONE KGH Series Fuse-Switch-Disconnectors. For Low Voltage ABC Systems or Open-wire Overhead Networks KRONE KGH Series Fuse-Switch-Disconnectors For Low Voltage ABC Systems or Open-wire Overhead Networks Putting the Power in Your Hands... The KRONE KGH Range The KRONE type KGH Fuse-Switch- Disconnectors

More information

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings Insulation Piercing Connectors Dulmison, through its partnership with Michaud in France, provide a comprehensive range of Insulation Piercing Connectors - IPC's. Michaud's dedication to product quality

More information

CONNECTORS AND FITTINGS

CONNECTORS AND FITTINGS Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Power cable accessories catalogue

Power cable accessories catalogue Power cable accessories catalogue Cable Lugs and Connectors Renewables A brighter future Jointing Tech is a specialist electrical distributor supplying a full range of power cable and accessories into

More information

Power cable accessories catalogue

Power cable accessories catalogue Power cable accessories catalogue Cable Lugs and Connectors Renewables A brighter future Jointing Tech is a specialist electrical distributor supplying a full range of power cable and accessories into

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

Chapter 1. Connectors & Fittings for Railways

Chapter 1. Connectors & Fittings for Railways Chapter Connectors & Fittings for Railways Current Carrying Catenary Dropper Component N Messenger Bz Cable length from L Component N 3 Component N 2 Contact Wire SNCF approved This dropper provides a

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail Part 5 LV Underground Drawing Register Number U8 U9 Description URD Mini Pillar Installation Guide UDS Universal Pillar Installation Guide U10-1 UDS Universal Pillar Double Link Unit Drilling Detail U10-2

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

Underground Distribution

Underground Distribution Aluminum Flood-Seal TM Mechanical Connectors Save outlet space These connectors feature the Sweetheart TM outlet configuration that nests two equal-sized service cables from #6 to 2/0 or two different-sized

More information

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables cmi XLPE s PRODUCT CATALOGUE Electric Wire & s Complies to AS/NZ Standard cmi XLPE s www.cmielectrical.com.au A division of CMI Operions Pty Ltd ABN 87 088 279 270 For over 15 years XLPE s has provided

More information

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories

More information

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract

More information

Safety Lampholders and Pendants

Safety Lampholders and Pendants Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring

More information

LMV RANGE CONTENTS. General information

LMV RANGE CONTENTS. General information General information LMV RANGE CONTENTS Basic safety information. 2 Main features...... 3 Intermateability.. 3 Characteristics....... 4 Connection system.... 4 Ordering information Standard connector part

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

CONNECTORS - SINGLE POLE

CONNECTORS - SINGLE POLE CONNECTORS - SINGLE POLE CROCODILE CLIPS DAVID USE PHOTO SD0010 TERMINAL POSTS SOLDER TAGS CRIMP CONNECTORS CRIMPING TOOLS DAVID USE PHOTO SD0010 BOOTLACE FERRULES 2127 CABLE SPLICES 2128 CRIMP CONNECTORS

More information

Distribution Blocks & Bus-bar Solutions

Distribution Blocks & Bus-bar Solutions Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided

More information

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/ Han K 3/0, K 3/2 / Han HC Contents Page Technical characteristics Han K 3/0, Han K 3/2... 14.02 Inserts Han K 3/0, Han K 3/2... 14.03 Hoods/Housings Han 24 HPR for Han K 3/0, Han K 3/2... 14.04 Technical

More information

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01 SECTION H EARTHING ABC Earthing Kits H01 ABC Earthing Kit 4 legged ABC earth kit. Each leg of the earth truss terminates with a female bayonet type pipe connector with a protective rubber hand guard. These

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

Volume-III : Section-I 370 Technical Specifications

Volume-III : Section-I 370 Technical Specifications Volume-III : Section-I 370 TECHNICAL SPECIFICATION-PIERCING INSULATOR 5.1 Insulation Piercing Connectors (IPC) 5.1.1 Insulation Piercing Connectors (IPC) are used for making Tee/Tap-off/Service connectors

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire

More information

Heavy Duty Copper Battery Terminals

Heavy Duty Copper Battery Terminals Heavy Duty Copper Battery Terminals Constructed of 131 contact copper to provide high conductivity. Raised characters to ensure legibility of important information regarding cable size, post type, and

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

TRANSNET. The NEW ERA in Power Distribution HV JUICE. Raychem GelPort Now up to 300mm2 ECO PILLAR. October November 2013

TRANSNET. The NEW ERA in Power Distribution HV JUICE. Raychem GelPort Now up to 300mm2 ECO PILLAR.   October November 2013 TRANSNET 100% NZ OWNED HV JUICE October November 2013 The NEW ERA in Power Distribution ECO PILLAR LOW PROFILE, UNOBTRUSIVE DESIGN Raychem GelPort Now up to 300mm2 CRSM-CT-M Single Core Branch Joint up

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

TRELLEBORG ENGINEERED PRODUCTS. Electrical Safety Products

TRELLEBORG ENGINEERED PRODUCTS. Electrical Safety Products Electrical Safety Products Highest standard of protection. A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg specifically

More information

Construction and Wiring Guidelines for Ergon Energy Substation Panels

Construction and Wiring Guidelines for Ergon Energy Substation Panels Construction and Wiring Guidelines for Ergon Energy Substation Panels Table of Contents Purpose and Scope... 1 Responsibilities... 1 Definitions, Abbreviations and Acronyms... 1 References... 1 Panel Wiring...

More information

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools Medium voltage - Cable accessories up to 36 kv Tapes Connection technique Tools TABLE OF CONTENTS General information... 6 7 CAST RESIN-TECHNIQUE...8 11 Straight-through joints for polymeric-insulated

More information

web:

web: web: CONTENTS INTRODUCTION 00 CU LUGS 00 TERMINALS 00 HEAT SHRINKABLES 00 CABLE TIES 00 CABLE MARKERS 00 GLANDS 00 CLEATS 00 PVC TAPES 00 INTRODUCTION Aftec Electrical Solutions Aftec international with

More information

Electrical connection systems

Electrical connection systems 1 Electrical connection systems Copper tubular cable lugs and connectors 10 Tubular cable lugs 10 Tubular cable lugs for switchgear connections 16 Angle tubular cable lugs 17 Connectors 21 Insulated tubular

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV

More information

Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv

Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Features

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION HEAT SHRINKABLE TERMINATION FOR 11kV, 3 CORE, XLPE/PVC COPPER WIRE SCREEN UNARMOURED CABLE. INDOOR & OUTDOOR. Cable Dielectric INDOOR INSTRUCTION No PJT001-14A XLPE/EPR OUTDOOR Tested to IEC60502-4 (TDT

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Approvals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL

More information

TRIED & TESTED All of our products have been tried and tested used and reviewed by Licensed Australian Electricians.

TRIED & TESTED All of our products have been tried and tested used and reviewed by Licensed Australian Electricians. Electrical Factory Outlet Pty Ltd Accredited Service Providers 2016 Catalogue Electrical Factory Outlet Electrical Factory Outlet is an Australian owned and operated company, specialising in high quality

More information

CO P P E R C A B LES A N D C O N N E C TO R S (P TY)

CO P P E R C A B LES A N D C O N N E C TO R S (P TY) CCC Copper Cables & Connectors (Pty) Ltd, established in 1990, specialises in design and manufacture or repair of Water-Cooled Furnace Cables, Air-Cooled Furnace Cables, Water-Cooled Resistance Welding

More information

CONTENTS TERMINAL BLOCKS

CONTENTS TERMINAL BLOCKS CONTENTS SECTION 7 SECTION 7..................................57...........................................58...........................................59 STUD TYPE RAIL MOUNTED...........................................60

More information

Electrak powertrack / underfloor busbar system

Electrak powertrack / underfloor busbar system design and installation n General installation notes Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm Feed units are provided with one or two 25 mm diameter

More information

SUBMERSIBLE SECONDARY CONNECTORS

SUBMERSIBLE SECONDARY CONNECTORS SUBMERSIBE SECONDARY CONNECTORS TYPE SSBC350- (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEA RUS Approved User friendly wide-port spacing (50% more room for cable training). Multiple

More information

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success

More information

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n GT Nylon Cable Ties 4 GT Nylon Cable Ties - Color 5 GS Screw-Mount

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

Quintas & Quintas Group

Quintas & Quintas Group Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors

More information

ACCESSORIES - Electronic Daylight Switch - Cadmium Sulphide Daylight Switch Accessories 8.1 8.1 8.2 Daylight Switch Daylight Switch Daylight Switch D2 Wire-In PBL s 8.2 8.2 8.2 Docklite Docklite Light

More information

FISCHER FREEDOM TM SERIES

FISCHER FREEDOM TM SERIES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

HAVE YOU SEEN THE RANGE OF KULAK & URD PRODUCTS?

HAVE YOU SEEN THE RANGE OF KULAK & URD PRODUCTS? HAVE YOU SEEN THE RANGE OF KULAK & URD PRODUTS? Extra Large Pillar Top & Base ABA s extra large tops & bases allow for increased work space and are interchangeable with standard tops & bases. Air Flow

More information

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET ER47 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Int Time Allowed: Three

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

Power cable accessories catalogue

Power cable accessories catalogue Power cable accessories catalogue Capability Your connection point Staying up to date with the latest network approval documents can be time consuming and complicated. That s why the Jointing Tech team

More information

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length

More information

CONTENTS OVERHEAD SLEEVES AND LUGS

CONTENTS OVERHEAD SLEEVES AND LUGS CONTENTS OVERHEAD SLEEVES AND LUGS SECTION 5 SECTION 5 OVERHEAD CONDUCTOR SLEEVES & LUGS..................45 NON TENSION SLEEVES.......................................46 FULL TENSION SLEEVES TYPE A...............................46

More information

DISTRIBUTION DESIGN CATALOGUE

DISTRIBUTION DESIGN CATALOGUE DISTRIBUTION DESIGN CATALOGUE Section 16 UM Unmetered Supply HPC-1DC-07-0016-2014 For application to Horizon Power Electricity Distribution Networks Document Control Author Name: Paul Savig Position: Senior

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2

Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2 12A Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2 Maximum input pressure: 700 bar Oil volume required : 90 cc Output force : 226 kn 280 (L) mm 7.5 kg Steel carrying

More information

September Cable termination solutions Lugs and tools for reliable crimping

September Cable termination solutions Lugs and tools for reliable crimping September 2016 Cable termination solutions Lugs and tools for reliable crimping ABB products are part of your success Designed to perform 1 2 3 4 5 7 6 7 8 1 Rail and transportation 2 Power utility and

More information

LMF / LMG RANGE ACCESSORIES CONTENTS

LMF / LMG RANGE ACCESSORIES CONTENTS CONTENTS Application of Cable Entry Fittings..... Ordering Information... 4 Outlet Accessory Sets..... 5-7 Protective Caps for Aluminium Range.. 8 Protective Caps for Brass Range (Brass)..... 9 Protective

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

High Voltage Cable Accessories Product catalog

High Voltage Cable Accessories Product catalog High Voltage Cable Accessories Product catalog 1300 780 831 info@cablegrid.com.au www.cablegrid.com.au Table of Contents page 1 HV Terminations 3 Dry type plug in GIS and Transformer terminations 5 GIS/Transformer

More information

Type SJK Test Switches

Type SJK Test Switches Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES

More information

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions Raychem CSJA 1521 Cold-Shrinkable Splice for single core polymeric insulated (XLPE-EPR) cables up to 15kV for tape, wire, Unishield, LC shield, JCN, and flat strap neutral cable UniShield is a trademark

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION Accessories Introduction While a number of cable related accessories are available on the market, RFS components are of the highest quality and are designed to provide years of trouble-free service. Together

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

MR - MEDIUM RATING A

MR - MEDIUM RATING A 88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118

More information

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E 17 DISTRIBUTION OHL FITTINGS 01 Contents General... 3 Insulator pin straight with round thread, according to ÖNORM E4175... 5 Oscillating top clamp for aluminium based conductors... 5 Side tie for aluminium

More information

INDUSTRIAL COMPONENTS CATALOGUE. Terminals, switches and fuse bases

INDUSTRIAL COMPONENTS CATALOGUE. Terminals, switches and fuse bases INDUSTRIAL COMPONENTS CATALOGUE Terminals, switches and fuse bases 2 Ensto at your service Ensto is an international industrial group and a family business specialising in the development, manufacture

More information

H e a t s h r i n k P r o d u c t G u i d e

H e a t s h r i n k P r o d u c t G u i d e P o w e r P r o d u c t s H e a t s h r i n k P r o d u c t G u i d e Introduction HellermannTyton is a world leader in providing systems and solutions for heatshrink applications. HellermannTyton utilises

More information

adaptable, reliable underfloor power

adaptable, reliable underfloor power adaptable, POWERTRACK reliable adaptable, reliable underfloor power 6 THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

(K),(M),(P)489TB/G Up to 42 kv

(K),(M),(P)489TB/G Up to 42 kv IS91374-ENG - 489TB/G-45/S 22 October 2012 - Revision 1 - Supersedes edition of 4 May 2012 Page 1 of 9 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation

More information

SYSTEM PROTECTION - PLATING

SYSTEM PROTECTION - PLATING INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.

More information

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Tender Schedule. Sl. No. Particulars Quantity Unit Rate ` Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

introducing the new macey range of waterproof and flameproof connectors for the oil & gas industry

introducing the new macey range of waterproof and flameproof connectors for the oil & gas industry introducing the new macey range of waterproof and flameproof connectors for the oil & gas industry new macey manufactures high voltage electrical connectors used in exposed environments such as mines,

More information

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 36 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed Aqua-safe Waterproof Plug & Socket Connectors Simply better designed 2 Aqua-safe Simply better designed Elkay s Aqua-safe is the only all-round solution for safely connecting and carrying power through

More information

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016 No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

Cast Resin Joints. Install and Forget

Cast Resin Joints. Install and Forget Install and Forget The new range of Rezi-Kon cast resin joints from Thomas & Betts provide a convenient and reliable solution for splicing and branching low voltage cables, in applications like street

More information

GMT Fuse Panel Installation Guide

GMT Fuse Panel Installation Guide GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

Tube Remover and Installer. and Installer Used for servicing Ford systems produced after Screen Extractor. Ford Aerostar Expansion

Tube Remover and Installer. and Installer Used for servicing Ford systems produced after Screen Extractor. Ford Aerostar Expansion gauges A/C FLUSH KIT Easy-to-use system removes refrigerant oil, moisture contaminants from system components lines during retrofitting compressor replacement. Kit includes rubber-tipped flush gun, canister

More information

VP RP BP GP HALOGEN FREE INSULATED TERMINALS. P range funnel entry OPERATING TEMPERATURE UP TO 115 C

VP RP BP GP HALOGEN FREE INSULATED TERMINALS. P range funnel entry OPERATING TEMPERATURE UP TO 115 C VP RP P GP HAOGEN FREE INSUATED TERMINAS P range funnel entry OPERATING TEMPERATURE UP TO 115 C The P range of terminals has been designed, to meet the increasing demands for improved safety and reliability

More information

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES J-2 Grounding Equipment Accessories. www.salisburybyhoneywell.com BALL & SOCKET SYSTEM BALL STUDS

More information

Low Voltage Energy. Creator of electrical equipment. Catalogue Low Voltage Energy

Low Voltage Energy. Creator of electrical equipment. Catalogue Low Voltage Energy Creator of electrical equipment Catalogue Low Voltage Energy Michaud Export Engineering & creativity Complete range of Low Voltage products Partner for energy access Michaud has been designing, qualifying,

More information