氣體絕緣開關部份放電線上監測系統 ABB Partial Discharge monitor system
|
|
- Solomon Blair
- 5 years ago
- Views:
Transcription
1 Purvis Chen, Power Products Division, ABB Taiwan, Oct. 29,2014 氣體絕緣開關部份放電線上監測系統 ABB Partial Discharge monitor system October 30, 2014 Slide 1
2 Content Basic introduction for partial discharge Application for radio wave & Ultra high frequency Concept of PD sensor installation Benefit about step by step setup PD system PD system installation overview Service provided after ABB PD system installation ABB recommend sensor install point October 30, 2014 Slide 2
3 Basic introduction for partial discharge October 30, 2014 Slide 3
4 Application for radio wave & Ultra high frequency October 30, 2014 Slide 4
5 PD sensor installation position Barrier insulator front view Types of non-conventional sensors---integrated sensor In the three phase encapsulated GIS type considered, each separating gas barrier insulator includes auxiliary potential grading electrofes of a certain geometry which support stress control October 30, 2014 Slide 5
6 PD sensor installation concept Data collection computer Junction box Connection view October 30, 2014 Slide 6
7 Benefit - step by step setup PD sensor Stage-4 Stage-1 Stage-2 Stage-3 Stage-5 Stage-6 Stage-7 Sensor installation as above drawing 7 stage to install sensors on barrier insulator (red mark area) Partial installation Monitor area could be customization ABB provided 4 times free data collection & report ( if customer purchase 6 pcs sensor at once ) At the initial stage data collection and equipment will be provided by ABB For example : Barrier insulator position on E07 bay October 30, 2014 Slide 7
8 PD sensor installation reference list (world wide) October 30, 2014 Slide 8
9 PD sensor installation reference list (world wide) PD sensor installation reference list (Taiwan) From 2013 ~ now Starbuck this plant GIS total 6 bays - Incoming bay 6 pcs sensors installed on end of 2013, plan to install another 6 pcs sensors on outgoing bay end of 2014 Haw-Ya power plant GIS total 19 bays - 8 pcs sensors installed on outgoing bay end of 2013, and plan to build up on line monitor system ( under discussion) Mxic-5 GIS total 5 bays - 5 PCS sensors will be installed on end of 2014 (each bay for 1 pcs sensor rough monitor for all substation) October 30, 2014 Slide 9
10 Q & A 1. Option for ABB PD system? Portable PD system (only sensor installed, data collection and report will be provided by ABB 4 times free not on line monitor (min purchase : 6 pcs sensors) On line PD system (Fully auto) need to purchase all relevant PDM equipment Portable system (PD sensor installed only) On line PD system PD sensors Monitor area defined by customer (Min: 6 pcs sensors required ) 49 PCS sensors (corning substation) Incoming bays total: 24 pcs sensors Tie bay total: 8 pcs sensors Outgoing bays total 17 pcs sensors PD instrument Provided by ABB Need to purchase Data collection 4 times support for free by ABB Data collect only when PD instrument connected 24 hours monitoring after system setup Price 40,000(USD) 600,000(USD) October 30, 2014 Slide 10
11 Q & A 2. Cost estimation ( to be confirmed again in quotation stage) Sensor package is 40,000 USD 6 PCS UHF sensors connection cables data collection support by ABB (4 times for free) measurement report On line PD system is about 600,000(USD) 49 PCS UHF sensors Industrial PC PD monitor instrument GIS monitor software Calibration impulse generator System setup by ABB Etc..(need to confirm on design stage) 3.What is the material of barrier insulator? Epoxy resin 4.Any risk during the sensor installation and how to prove it? Material of barrier insulator is epoxy resin GIS on line working permitted by ABB ( power shut down is not necessary ) Leakage detection tool ( to verify if any SF6 leak from the barrier insulator) Voltage detection tool ( to verify if ant voltage around the barrier insulator October 30, 2014 Slide 11
12 Service provided after ABB PD system installation PDM system installation Training by ABB Data collection support Data Analysis support by DEABB Abnormality signal tracing support PD signal database World wide experience Extend GIS life time October 30, 2014 Slide 12
13 ABB recommend sensor install point For Corning GIS system ABB suggests to install at least 22 PCS sensors show as above black mark on barrier insulator. Indicate PD signal comes from GIS or TR side October 30, 2014 Slide 13
14
Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2
Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2 Table of Contents 1 Introduction... 4 2 Description of retrofit circuit-breaker 8DN8... 5 3 Technical data for retrofit circuit-breaker
More informationCustomer presentation, PG Service, BU Motors and Generators ABB LEAP Stator Winding-Condition & Lifetime assessment
Customer presentation, PG Service, BU Motors and Generators ABB LEAP Stator Winding-Condition & Lifetime assessment ABB LEAP Overview ABB LEAP - Benefits for customer Motivation to perform LEAP Failures
More informationOverview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1
Overview Gas Insulated Switchgear Modular and flexible, 52-1100kV April 17, 2009 Slide 1 Tradition and Innovation Milestones from more than 40 Years of Experience Pioneer & Leader in GIS-Technology 1956
More informationOverview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1
Overview Gas Insulated Switchgear Modular and flexible, 52-1100kV May 15, 2013 Slide 1 Tradition and Innovation Milestones from more than 40 Years of Experience Pioneer & Leader in GIS-Technology 1956
More informationSolution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime
Solution Overview Asset Condition Monitoring Extend operational life and reduce downtime QUALITROL Integrated Monitoring Server : Data Integration Diagram SMARTSUB Substation Condition Monitoring: Transformer
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does
More information型號 SLK-1500 SLK-2000 SLK-3000 SLK-4000 最大輸入功率 1750W 2340W 3510W 4700W 最大輸入電壓 500VDC 500VDC 500VDC 500VDC
Input data 型號 SLK-1500 SLK-2000 SLK-3000 SLK-4000 設備外觀圖 最大輸入功率 1750W 2340W 3510W 4700W 最大輸入電壓 500VDC 500VDC 500VDC 500VDC 最佳輸入電壓 (DC) 360V~400V 最大功率點追蹤範圍 150V to 500V ±5% 最低起動電壓 100V ±5% 工作電壓範圍 100±5%
More informationM-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)
M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions
More informationKILOTECH. KWD 500 Water tight. Portion/Weighing Scale
KILOTECH KWD 500 Water tight Portion/Weighing Scale Operation Manual Version 1.0 Last Modified: Jan 2006 1 Industrial Weighing Systems 9 Richmond St. Picton, ON Canada K0K 2T0 Ph: 613-786-0016 Cell: 613-921-0397
More informationThe Colt Group Power Services Division
September 10, 2014 REPORT ON SF6 LEAK REPAIR COMPLETED AT SOUTHERN CALIFORNIA EDISON (SCE) VALLEY 115kV GIS - SECTION 119C The Colt Group, was contacted by the Manufacturer in July 2014 to repair an SF6
More informationGas Insulated Switchgear
Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology
More informationPASS M0. Innovative solutions for distribution substations up to 170 kv
PASS M0 Innovative solutions for distribution substations up to 170 kv The concept In the today s changing market, the substation is becoming more and more a key element to meet end users requirements
More informationB kv T&D GAS INSULATED SWITCHGEAR
GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission
More informationGas Insulated Switchgear ELK-0. for stations up to 170 kv, 4000 A, 63 ka
Gas Insulated Switchgear ELK-0 for stations up to 170 kv, 4000 A, 63 ka Content General 3 Set-up of a substation 4-5 The system and its components 6-17 Busbar with combined disconnector and earthing switch
More informationCABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.
MV-CONNEX, HV-CONNEX, IXOSIL Terminations, IXOSIL MSA Slip-on Joint Boxes CABLE SYSTEMS Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. Welcome to the CABLE SYSTEMS Centre of Competence.
More informationZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.
ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW High performance alternative to air
More informationPPL Gas Insulated Substations: Design Considerations and Lessons Learned. Nicholas Matone Support Engineer, T&S Standards
PPL Gas Insulated Substations: Design Considerations and Lessons Learned Nicholas Matone Support Engineer, T&S Standards Agenda PPL Overview Previous GIS Experience Present GIS Installations Mobile GIS
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationSF6 free high-voltage GIS installation in Zürich, CH.
SF6 free high-voltage GIS installation in Zürich, CH. Dr. Walter Holaus, Global Product Manager, ABB Switzerland. 25.11.2015 Current developments in High-voltage switchgear Some examples November 27, 2015
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationFEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation
FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation agenda Fundamentals Compelling value Product line overview VerSaVac (VSV) Product features and benefits Design Ratings Applications
More informationCERTIFIER MODEL 912 CERTIFIER 912 Brake Timing Test
CERTIFIER MODEL 912 CERTIFIER 912 Brake Timing Test CERTIFIER 912 Brake Timing Test Revision History: Name Date Changes Version # Gene Ambacher October 5, 2013 Initial Draft 1.0.0 Gene Ambacher October
More information3AP1 DTC for 145 and 245 kv
The Hybrid Solution 3AP1 DTC for 145 and 245 kv siemens.com/answers Solutions for switchgears and substations fully encapsulated h y b r i d Grade of encapsulation partly encapsulated not encapsulated
More informationEvaluation of Pile Setup using Dynamic Restrike Analysis in Alabama Soils
45 th STGEC - Mobile, AL Oct. 29, 2014 CE Pile 360 Setup Spring AL 13 Evaluation of Pile Setup using Dynamic Restrike Analysis in Alabama Soils Eric Steward, Ph.D. Assistant Professor University of South
More informationtests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.
tests ( Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed. electrical tests These tests verify contractual
More informationFlow Computer Installation
Flow Computer Installation WARNING: Only personnel who are experienced with field wiring should perform these procedures. All field wiring must conform to the National Electrical Code, NFPA 70, Article
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationExtra-High-Voltage SF 6 Gas-Insulated Switchgear
Extra-High-Voltage SF 6 Gas-Insulated Switchgear Shuichi Sugiyama Masahiko Fujita Takahiro Shinohara 1. Introduction Due to location criteria and toughened restrictions on transportation, it has become
More informationGas Insulated Switchgear
Gas Insulated Switchgear 25.8kV Gas Insulated Switchgear 36kV Gas Insulated Switchgear 72.5kV Gas Insulated Switchgear 145kV Gas Insulated Switchgear 170kV Gas Insulated Switchgear 245kV Gas Insulated
More informationF SPS Commissioning Check Sheet Template
F8943 - SPS Commissioning Check Sheet Document Details This document is only valid on the day it was printed. Document Owner References Manager Capital Delivery SPS Commissioning Worksheet End to End Test
More informationIndependent Testing Laboratory for High Voltage Equipment
T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.
More informationProduct Change Notice
Product Change Notice Product Change Information: The internal DDR of SQFlash 820 (-S) Series SATA III products will have lithography upgrade from current 42nm to 30nm. The new DDR will be implemented
More informationCompact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)
Compact Gas Insulated Switchgear (GIS) up to 45 6,45 Compact Gas Insulated Switchgear (GIS). Standard: IEC 6703. Typical Feature. Great Breaking Character of Circuit Breaker The circuit breaker adopt the
More information翔鑫科技股份有限公司. Oro Technology Co., LTD. 無線胎壓監測器 Tire Pressure Monitoring System 型號 : W410
翔鑫科技股份有限公司 Oro Technology Co., LTD 無線胎壓監測器 Tire Pressure Monitoring System 型號 : W410 ORO TPMS User Manual To ensure correct operations and services please read these instructions before installing and
More informationEnergy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.
Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that
More informationHigh Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide
1ZUA2761-500 rev. 5, 6 April 2010 High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide 1ZUA2761-500 rev. 5, 6 April 2010 2 / 9 Table of contents 1 Description... 3 2 Ratings...
More informationModular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.
Modular Capacitor Systems Reactive Compen sation Copyright 2002 ABB. All rights reserved. 12/12/2002 Needs Customer A solution to suit Modular Substations Relocatable assets More value for money ABB A
More informationGas-insulated switchgear from 72.5 to 550 kv. Excellent systems that create lasting value. siemens.com/energy-management
Gas-insulated switchgear from 72.5 to 550 kv Excellent systems that create lasting value siemens.com/energy-management Siemens 8DN8 switchgear for up to 170 kv is characterized by modular design and excellent
More informationMOBILE SUBSTATION GUIDE
MOBILE SUBSTATION GUIDE Certificate Number FM35831 Mobile substations by their nature offer the flexibility and the opportunity to ensure a reliable energy supply. Mounted on a trailer, their compact and
More informationStefano Cervidi - ABB S.p.A. PPHV Santiago de Chile J.T. ABB Chile de Abril 2015 PASS - Plug and Switch System Subestaciones con tecnologìa
Stefano Cervidi - ABB S.p.A. PPHV Santiago de Chile J.T. ABB Chile 14-15 de Abril 2015 PASS - Plug and Switch System Subestaciones con tecnologìa hibrida PASS ABB in Lodi - History Long heritage based
More informationROBERTO BERNACCHI, GLOBAL PRODUCT MANAGER, 16 JUNE 2018 New power infrastructure concept for greener container terminals Creating Stronger, Smarter
ROBERTO BERNACCHI, GLOBAL PRODUCT MANAGER, 16 JUNE 2018 New power infrastructure concept for greener container terminals Creating Stronger, Smarter and Greener port grids 1 greener Stronger, smarter and
More informationVEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY
VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 New RIS transformer bushings The paper-free solution Transformer condenser bushings Why a new technology? To preserve
More information1 of :23
1 of 8 2013.02.09 03:23 Published: 08-Jun-2012 Electronic Engine Controls - TDV8 3.6L Diesel - Electronic Engine Controls 3.6L (TdV8) Diesel Diagnosis and Testing Overview This section covers the components
More informationHigh Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK
High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK Definitions Transmission Line Arresters Backflashover Occurs when lightning strikes the tower structure or overhead
More informationGas Insulated Substation Testing and Application
Gas Insulated Substation Testing and Application Course No: E02-020 Credit: 2 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P:
More informationUniGear. Technical Guide
UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating
More informationSimple Demonstration of the Seebeck Effect
Simple Demonstration of the Seebeck Effect Arman Molki The Petroleum Institute, Abu Dhabi, United Arab Emirates amolki@pi.ac.ae Abstract In this article we propose a simple and low-cost experimental set-up
More informationZX2 Gas-insulated medium voltage switchgear
Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters
More informationABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers
ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type
More informationOutline. Background Performed evaluations. General experiences Future work. ATAM Experiences. Architecture used in 3O3P project SA-AFL architecture
Xiaohong Jin Pia Stoll Mariana Olsson Corporate Research ABB ATAM Experiences ABB AB, Corporate Research - 1 3/29/2005 Outline Background Performed evaluations Architecture used in 3O3P project SA-AFL
More informationTraining Courses Information
Training Courses Information Health & Condition Monitoring Center Sustainable Manufacturing Systems Laboratory Iran University of Science & Technology Condition Monitoring, Maintenance & Reliability (Overview)
More informationANDERSON, ECKSTEIN AND WESTRICK, INC.
ANDERSON, ECKSTEIN AND WESTRICK, INC. 51301 Schoenherr Civil Engineers Road, Shelby Township, Michigan 48315 Surveyors Architects 586-726-1234 Mr. Matthew Tepper City of Grosse Pointe Farms 90 Kerby Road
More informationGAS INSULATED VOLTAGE TRANSFORMERS.
GAS INSULATED VOLTAGE TRANSFORMERS. This document may be subject to changes. Contact ARTECHE NISSIN to confirm the characteristics and availability of the products described here. CONTENTS 1. Presentation
More informationREDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2
RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2 REDUNDANT PROPULSION JANUARY 2011 CONTENTS PAGE Sec. 1 General Requirements... 4 Sec. 2 System
More informationBlancett Flow Meters A Division of Racine Federated Inc. 100 East Felix Street South, Suite 190 Fort Worth, Texas FAX:
Active Sensor Installation and Operation Manual - Preliminary Frequency-to-Current/ Frequency-to-Voltage Converter For use with Blancett Model 1100 Series Turbine Flow Meters Introduction The Active Sensor
More information11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls
11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the
More informationAssembly and Handling Precautions for COB LEDs
Assembly and Handling Precautions for COB LEDs Table of Contents 1. Overview 2. General Structure and Features of s 3. Typical Applications 4. How to Attach s to a Luminaire 5. Handling Precautions 6.
More informationNational Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance
National Grid UK Electricity Transmission plc NATIONAL SAFETY INSTRUCTION and HIGH VOLTAGE METAL CLAD SWITCHGEAR WITH SPOUTS Copyright National Grid plc 2014, all rights reserved. No part of this publication
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More informationCetane ID 510. Customer Presentation. Refining. Petrochemical
Refining Cetane ID 510 Customer Presentation Petrochemical Cetane ID 510 Easy to use One button operation Fully automated Test Fully automated Calibration High pressure injector for better combustion Improved
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationB kv Gas-insulated Substations
72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.
More informationScientech Stresswave SRV Leak Detection Scientech Symposium 2015
Scientech Stresswave SRV Leak Detection Scientech Symposium 2015 1 September 17, 2015 Curtiss-Wright SRV SRV = Safety Relief Valve A pressure relief vessel which automatically releases a substance from
More information2.5X2.0mm SURFACE MOUNT LED LAMP. PRELIMINARY SPEC Part Number: KT-2520SE9ZS-RV Reddish-Orange. Typical Applications. Features. Package Dimensions
2.5X2.0mm SURFACE MOUNT LED LAMP PRELIMINARY SPEC Part Number: KT-2520SE9ZS-RV Reddish-Orange Features Dimension: 2.5mmx 2.0mm x 0.8mm. Low thermal resistance. Ceramic package with silicone resin. Small
More informationDURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA
DURESCA Busbar system For indoor and outdoor applications, type DE / type DG DURESCA DURESCA Busbar system Swiss quality combined with global experience PRODUCT OVERVIEW Moser Glaser General description
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationCaster Strand Monitoring System Roll Checker
Roll Checker ROLL CHECKER Roll condition measurement of the strand is necessary for quality improvement of the slab produced by continuous casting POWER MnC successfully developed the Roll Checker in cooperation
More informationAll-SiC Module for Mega-Solar Power Conditioner
All-SiC Module for Mega-Solar Power Conditioner NASHIDA, Norihiro * NAKAMURA, Hideyo * IWAMOTO, Susumu A B S T R A C T An all-sic module for mega-solar power conditioners has been developed. The structure
More informationThe Proven Mixproof Range
The Proven Mixproof Range SMP-BC Sanitary Mixproof Valve PD 65373 US4 22-9 Application SMP-BC is a sanitary pneumatic seat valve, designed for safety and leak detection when two different products flow
More informationNXPLUS C Single busbar. Maintenance-free for lifetime
NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage
More informationTitle: M.I.L. ON DTC P3191, P3190, AND/OR P0A0F Models:
Technical Service BULLETIN October 18, 2004 Title: M.I.L. ON DTC P3191, P3190, AND/OR P0A0F Models: 04-05 Prius EG047-04 ENGINE TSB REVISION NOTICE: S February 22, 2005: Applicable Vehicles has been updated
More informationSF6 Gas-Insulated Metal Enclosed Switchgear
SF6 Gas-Insulated Metal Enclosed Switchgear 24-36 kv, 3 sec (LSC2A, PM) Standard IEC 62271-200 Nature is Our Most Valuable Partner GIS-EN-12-01 SF6 Gas-Insulated Metal Enclosed Switchgear CONTENTS 1.INTRODUCTION...
More informationMaxSG Low Voltage Switchgear
Low Voltage Products & Systems Automation Technology MaxSG Low Voltage Switchgear ABB Automation Technologies MaxSG ABB Slide 2 June 2009 Product verview Key Features and Benefits Construction nstrumentation
More informationRelay Retrofit Program Cutting Tool Safety Guide
Relay Retrofit Program Cutting Tool Safety Guide Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationThe University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 2 SWITCHBOARDS Overview Also called Switchgear and Controlgear Assembly
More informationTHP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com
THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated
More informationAccident, Maryland, USA
CABLE CIRCUIT BREAKER MOTOR GENERATOR G GIS SWITCHGEAR RECLOSER PROTECTIVE EQUIPMENT INSULATION PORTABLE MATERIALS Accident, Maryland, USA www.phenixtech.com +1.301.746.8118 Phenix Technologies Phenix
More informationElectrical Test of STATCOM Valves
21, rue d Artois, F-75008 PARIS 619 CIGRE 2016 http : //www.cigre.org Electrical Test of STATCOM Valves Baoliang SHENG 1, Christer DANIELSSON 1, Rolf NEUBERT 2, Juha TURUNEN 3, Yuanliang LAN 4, Fan XU
More informationProduct Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More informationUNIVERSAL CALIBRATING MACHINES
FIGURE 1-100,000 lbf Morehouse Universal Calibrating Machine using a Morehouse Proving Ring to calibrate a Load Cell in compression. An optional Auxiliary Screw Pump is attached to Machine s upper platen.
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationSubstation Concepts for the Future
Anders Sjoelin, ABB Power Systems IEEE Substations ti Committee Meeting Substation Concepts for the Future April 26, 2012 Slide 1 Reminder Anything that is in the world when you re born is normal and ordinary
More information5700 SERIES Low Energy Power Operator
Low Energy Power Operator introduction Low energy door operators were once considered a necessity only for those with physical challenges. Today, due to the population s busy lifestyles, the convenience
More informationZinc Oxide Surge Arrester PEXLIM Q
Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high
More informationGeometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress.
Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress. George Fofeldea Power Engineer, 3M Canada August 2018 Abstract 3M invented cold shrink
More informationINSTRUCTION MANUAL CRS Combined insulation bushing
INSTRUCTION MANUAL CRS Combined insulation bushing 5COH020200 CRS REV03 2 TABLE OF CONTENTS 1 SAFETY... 5 1.1 SAFETY INSTRUCTION... 5 1.2 SPECIFIED APPLICATION... 5 1.3 SAFETY NOTES ON THE EQUIPMENT OPERATION...
More informationBisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -
Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner Users Manual August 5, 2002 A Product By: Bisnet - 1 - DCPP Users Manual Table of Contents CHAPTER 1 PQ 2 4 What is PQ Squared? 4 CHAPTER
More informationUPS Wizard User s Manual
1. The communication cable M2502: This is a special designed cable for the communication of UPS with your PC; only connecting with the correct cable, the PC can detect the UPS. 2. The main window of the
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationBOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC
BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class
More informationAlvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2)
Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., ABB lead the intelligent revolution Intelligent technology (Part 2) Slide 1 Intelligent Monitor and Diagnosis The Expert System for Switchgear Slide
More informationED BWS. Back Warning System. 1 Chonan Technical Service Training Center
Back Warning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the concept of back warning system. To understand the function of back
More informationHigh Voltage Surge Arresters Buyer s Guide Section PEXLIM R
High Voltage Surge Arresters Buyer s Guide Section PEXLIM R Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching
More informationMorehouse Instrument Company
The Morehouse Universal Calibrating Machine is designed to use a compression force standard, proving ring or load cell to calibrate units under test in compression and tension. The reference standard and
More informationMetal Clad Air Insulated Switchgear
Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system
More informationUniSec Maintenance solutions
DISTRIBUTION SOLUTIONS UniSec Maintenance solutions ABB supports you to improve the reliability, safety and efficiency of your electrical equipment UniSec Maintenance solutions Table of contents 004 00
More information3 Phase Smart Controller
3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838
More information