Low energy consumption C4 fans in casing inovec micro-watt

Size: px
Start display at page:

Download "Low energy consumption C4 fans in casing inovec micro-watt"

Transcription

1 ow energy consumption C4 fans in casing Principle Field of application Construction Advantages Range and accessories Technical specifications Electrical specifications Aeraulic specifications and power consumption Acoustic specifications Implementation Electrical connections Settings Servicing Spare parts

2 ADVANTAGES ADES patented system. Integrated, pre-wired micro-watt unit Vertical or in-line discharge C4 Certification Ø16 mm Simple to install and adjust TECHNICA SPECIFICATIONS Dimensions and weight Vertical discharge (RV) Type H P Discharge Ø A Weight (Kg) 3 RV x 333 or Ø R PRINCIPE The is a low energy fan casing, which includes an electronic pressure regulator unit. This micro-watt unit is pre-wired and pre-programmed in the factory with a default operating pressure of 12 Pa. The system allows the operator to adjust the setpoint pressure across the whole airflow range (from min. to max. settings for a CMEV system fitted with variable grilles). As opposed to a classic unit, the operating pressure is constant, meaning that, at lower flow rates the speed of the fan is reduced, optimising the motor power consumption and the pressure behind the ventilation grilles. The savings in electricity consumption can be up to 75% over that of a standard CMEV unit. The has a C4 fire classification (diameter 16 mm - 4-1/2 hour) for the whole range. SCOPE New apartment buildings and renovated buildings. Tertiary residential buildings (or equivalent). CONSTRUCTION 7 models, up to 12, m3/hr. Galvanised metal casing, in versions with vertical discharges (RV) or horizontal, in-line discharges (RH). Monoblock casing with integrated micro-watt unit, pre-wired and programmed in the factory. Motor fan unit with belt/pulley driven twin turbine, fitted to sliding rails. Proximity switch. Wide, ergonomic doors. Anti-vibration mountings. Mounting pads Available in 'screw-fit casing', 'epoxy coated' and '6 Hz' versions with adjustable or factory-set pressure switch options. ADVANTAGES 2 versions available: Vertical or horizontal discharge, to match your personal installation requirements. Energy savings: Up to 3% over the previous range and 75% over a standard CMEV range. SINGE PHASE 5 or 6 Hz power supply: Single phase - 23V 5 or 6 Hz power supply. Acoustics: During low-speed operations, the pressure behind each grille is much lower than a traditional CMEV unit. The noise given off by the ventilation grille is thus much improved. Easy to install and set up: - Minimum interventions involving the casing: integrated unit, pre-wired in the factory. - The proximity switch is connected to a single phase supply. - The unit is pre-programmed in the factory to 12 Pa. RANGE Code Vertical discharge 3 micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV Horizontal discharge 3 micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH RANGE WITH A CHOICE OF OPTIONS Code Vertical discharge Basic equipment: 3 micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV micro-watt RV Options available: - Screw-fit casing - Epoxy-coated casing only - Adjustable pressure switch - Epoxy-coated casing - 6 Hz motor - Factory-set pressure switch + motor fan Horizontal discharge Basic equipment: 3 micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH micro-watt RH Options available: - Screw-fit casing - Epoxy-coated casing only - Adjustable pressure switch - Epoxy-coated casing - 6 Hz motor - Factory-set pressure switch + motor fan ACCESSORIES Code MS Pro M Ø 4 mm MS Inlet/Outlet Kit M Ø 5 mm MS Inlet/Outlet Kit M Ø 63 mm MS Inlet/Outlet Kit M Ø 71 mm RV x 396 or Ø RV x 396 or Ø RV x 473 or Ø RV x 473 or Ø RV x 557 or Ø RV x 557 or Ø Horizontal discharge (RH) Type H p Discharge Ø A Weight (Kg) 3 RH Ø RH Ø RH Ø RH Ø RH Ø RH Ø RH Ø EECTRICA SPECIFICATIONS Three-phase asynchronous motor 23/4 V, Class F, IP 55 protection index. 23V - 5 Hz single-phase power supply (except 12, 23/4 V three-phase power supply). Type Fire class C airflow (m 3 /h) Power Supply Number of poles Power rating Motor (kw) current (A) 3 C4 Ø Single C4 Ø Single C4 Ø Single C4 Ø Single C4 Ø Single C4 Ø 16 1 Single C4 Ø ph Ø A P Ø A P H H 2 3

3 AERAUIC SPECIFICATIONS AND POWER CONSUMPTION Airflow curves drawn up in accordance with French Standard EN ISO 581. = static pressure 3 micro-watt = power consumption. 4 micro-watt AERAUIC SPECIFICATIONS AND POWER CONSUMPTION Airflow curves drawn up in accordance with French Standard EN ISO 581. = static pressure 8 micro-watt = power consumption. 1 micro-watt Pa Pa 23 Pa Grille SR Pa 2 Pa 24 Pa Pa 2 Pa 24 Pa Pa Pa 23 Pa Pa 2 Pa 24 Pa Pa 2 Pa 25 Pa micro-watt micro-watt 3 12 micro-watt Pa 25 Pa Pa 2 Pa Pa 25 Pa Pa 25 Pa Pa 2 Pa Pa 25 Pa

4 ACOUSTIC SPECIFICATIONS Criteria complying with standards: - ISO 5136 acoustics of ducts, - ISO 3741 acoustic reverberations. wc: Noise levels in the ducting - in db. prl : Noise levels in the surrounding area (db) (measured at 4 m distance in clear air) - free exhaust wrl : Noise levels in the surrounding area (db) - free exhaust 3 micro-watt Frequency (Hz) Global (db(a)) 4 micro-watt 13 m 3 /h 12 Pa wc prl m 3 /h 12 Pa wc prl wrl NC 7 17 m 3 /h 2 Pa wc prl m 3 /h 2 Pa wc prl Frequency (Hz) Global (db(a)) 13 m 3 /h 13 Pa wc prl m 3 /h 13 Pa wc prl wrl NC m 3 /h 2 Pa wc prl m 3 /h 2 Pa wc prl micro-watt Frequency (Hz) Global (db(a)) 15 m 3 /h 12 Pa wc prl m 3 /h 12 Pa wc prl wrl NC m 3 /h 25 Pa wc prl m 3 /h 25 Pa wc prl micro-watt Frequency (Hz) Global (db(a)) 3 m 3 /h 12 Pa wc prl m 3 /h 12 Pa wc prl wrl NC 8 4 m 3 /h 25 Pa wc prl m 3 /h 25 Pa wc prl micro-watt Frequency (Hz) Global (db(a)) 25 m 3 /h 15 Pa wc prl m 3 /h 15 Pa wc prl wrl NC m 3 /h 25 Pa wc prl m 3 /h 25 Pa wc prl

5 ACOUSTIC SPECIFICATIONS Criteria complying with standards: - ISO 5136 acoustics of ducts, - ISO 3741 acoustic reverberations. wc: Noise levels in the ducting - in db. prl : Noise levels in the surrounding area (db) (measured at 4 m distance in clear air) - free exhaust wrl : Noise levels in the surrounding area (db) - free exhaust 1 micro-watt Frequency (Hz) Global (db(a)) 12 micro-watt 3 5 m 3 /h 18 Pa wc ,7 4 m 3 /h 22 Pa wc ,7 7 m 3 /h 22 Pa wc ,1 8 5 m 3 /h 18 Pa wc ,8 Frequency (Hz) Global (db(a)) 4 m 3 /h 25 Pa wc ,8 6 m 3 /h 1 Pa wc ,5 8 m 3 /h 25 Pa wc ,8 1 m 3 /h 18 Pa wc ,1 wrl NC 83 prl NC 68,5 INSTAATION Ensure compliance with recommendations of standard NF P (DTU 68.3). ift off the casing with a yoke Casing can be opened on two sides. Minimum distance: Anti-vibration mounting When servicing, turn off the power supply. Never leave foreign objects inside the casing. Chlorine vapour explosive atmosphere No chlorine vapour, no explosive atmosphere. 8 9

6 EECTRICA CONNECTIONS Proximity switch SETTINGS Interface Alarm pressostat Connect using the electrical 'lego block' in the cabinet via the lower cable gland (on the side of the casing) Relays: 25V AC/DC.4A Selectable values: Pa. Operating pressure pre-set at the factory to 12 Pa. For frequency converters ATV12 & 312, correspondence pressure/converter Pid: Pressure switch Blue Blue Brown Black MA Brown Black R AR Default R: The relays can control the contacts, cutting off the supply to the boilers if the fans stop. Breaking capacity of the pressure switch at 25V ~: Resistive: 5A max. Inductive: 3A max. Pressure (Pa) Value (%) Default value set at 46%. Adjusting the operating pressure Access to operating pressure settings using frequency converter Start-up ATV 12 (MONO/TRI) for all applications excl. 12 ATV 312 (TRI/TRI) for 12 ON Voltage, frequency and current intensity display on the frequency converters Data reading ESC ATV 12 (MONO/TRI) for all applications excl. 12 Settings: electrical connections Single phase power supply - 23V for micro-watt CMEV (excl. 12). Fit electrical protection upstream of the equipment, using a differential CB (compatible with all types of current, RCD - Type B as per EN 5178, IEC 755) with a sensitivity level of 3mA. Electrical connections must conform to NF C Connections must use cables with a minimum cross sectional area of 2.5mm² (1.5mm² for the 3-Phase 12 model). Check the belt tension after running for an hour by manually turning the belt through a quarter of a turn. Imax (A) Power supply (V) _ 23 V _ 23 V _ 23 V _ 23 V _ 23 V _ 23 V _ 4 V 3~ ATV 312 (TRI/TRI) for 12 Motor frequency Motor current Network voltage 1 11

7 SETTINGS Troubleshooting Problem Diagnostics Solution The fan does not start and the fan display screen is dark. The fan does not start but the fan display screen is active. The fan starts up then stops (from several seconds to several days). No power supply or CB/switch open. Power supply cabling fault. Regulator U/S. Regulator faults. Motor cabling defective. Automatic starter deactivated. Protective circuit breaker detects current leakage and opens. Regulator faults. - Check for presence of mains voltage. - Check that the protective circuit breaker is closed. - Check the power supply cables within the building running to the unit's disconnecter switch. - Check the power supply cabling within the unit, between the disconnecter switch and the regulator. - Identify and correct the fault causing the regulator to fail. - Change the regulator. - Analyse and correct the fault codes. - Reset the regulator faults and turn the power supply off then on again. - Check the wiring between the regulator and the motor and turn the power supply off then on again. - Check the bridge between the terminals I1 and +24V (applicable to regulators ATV12 and ATV312). Cut off the power and restart. - Check coherence of protection current and max. current consumption. - Check that the differential is a minimum of 3 ma. - Analyse and correct the fault codes. - Reset the regulator faults and turn the power supply off then on again. SETTINGS Error messages Regulator fault Code Error messages (main errors) /cause ATV 12 ATV 312 OCF bf Current too high. - Current in motor cabling too high or short circuited. - Unsuitable motor or sudden mechanical problem. SCF + chiffre SCF Earthing fault. - Problem with the insulation of the cabling or motor. InFE System fault. PHF ; USF PHF ; USF Voltage too low. OSF OSF Voltage too high. InF b ; OHF OHF Internal regulator overheat. - Internal operating fault. - Reset fault to zero and restart. - Supply voltage too low. - Brief mains supply cut-off. - Ambient temperature too high. - Regulator cooling fault. OF OF Motor blocked. - Check the motor. SOF ; OF SOF ; OF Motor overheating. FFI - The regulator has detected that the motor is overheating, check the load on the motor. Incorrect pressostat sensor signal. - Check pressostat sensor and wiring. The fan turbine rotates in the wrong direction. - Invert 2 phases (U,V,W) using the cable between the regulator and the motor. Maximum number of restarts on overheat fault reached. Regulator faults. - Analyse and correct the fault codes. - Reset the regulator faults. tnf ; OPF1 ; OPF2 tnf Motor power supply fault. - Check the wiring from the motor to the regulator - Check the condition of the motor wiring e ventilateur ne démarre pas et l'écran du variateur est allumé. The fan cannot reach the required pressure. The setpoint is incorrectly adjusted. The rotational frequency is set to 5 Hz (Mode light lit). - The fan is at the end of the pressure curve, the flow rate is greater than the level the fan can supply. - See operating pressure regulation diagram p Check the green connectors: wiring between terminals 6 and Check that the thermo-contact is closed and turn the power supply off then on again. Reset errors After having resolved the cause of the error message, it is advisable to carry out a resetting of the errors (see below). If there is a problem, contact our after sales department, giving the serial number of the unit, shown on the manufacturer's plate. The internal casing pressure reading is incorrect. - Check the pressure socket between the pressostat and the inside of the casing. - Check that the pressure tube is connected to outlet P2 on the pressostat. - Verify operation using an external pressure switch and compare the value we measured with the operating pressure set point (see operating pressure regulation diagram, p.11). 1- Press the Stop/Reset button 2- cr: confirm acquittal of a fault 12 13

8 MAINTENANCE For correct operation of the ventilation system, it is recommended that you have the equipment checked and serviced by a cleaning and maintenance firm. - The doors on the sides of the casing can be removed easily using a tool. All elements requiring servicing (impeller, motor, etc.) are easily accessible via hatches equipped with handles. Clean and remove dust from the fan blades as well as the other internal components as often as necessary and at least once a year. Do not use a high-pressure or steam cleaner. Check that the motor-fan is securely fitted. Check that there are no unusual noises. SPARE PARTS Horizontal discharge 9 7 SPARE PARTS No. 3 Size 1 Size 2 Size SE electrical cabinet door MW + IP SE base + silentbloc SE door + handles SE cooling SE MW sensors - electrical wiring Driven pulley and hub SE Ejector + silicon seal Drive pulley and hub SE fan for VERTICA DISCHARGE (RV) version SE fan for HORIZONTA DISCHARGE (RH) version Vertical discharge

9 ow energy consumption C4 fans in casing Principle The is a low energy fan casing, which includes an electronic pressure regulator unit. The has a C4 fire classification (diameter 16 mm - 4-1/2 hour) for the whole range. Advantages ADES patented system. Integrated, pre-wired micro-watt unit Vertical or in-line discharge C4 Certification Ø16 mm Simple to install and adjust ADES BORDEAUX - Tel.: +33 () Departments: ADES CERMONT-FERRAND - Tel.: +33 () Departments: ADES DIJON - Tel.: +33 () Departments: ADES GRENOBE - Tel.: +33 () Departments: ADES IE - Tel.: +33 () Departments: ADES YON - Agency - Rhône - Tel.: +33 () Departments: 69 ADES YON - Vallée du Rhône-Ain agency - Tel.: +33 () Departments: MARSEIES - ADES Aubagne - Tel.: +33 () Departments: 13-83(west)-84 ADES MONTPEIER - Tel.: +33 () Departments: ADES NANCY - Tel.: +33 () Departments: (south west) ADES NANTES - Tel.: +33 () Departments: ADES NICE - Tel.: +33 () Departments: A-2B-83 (east)-98 PARIS - ADES A COURNEUVE - Tel.: +33 () Departments: PARIS - ADES VITRY - Tel.: +33 () Departments: ADES RENNES - Tel.: +33 () Departments: ADES ROUEN - Tel.: +33 () Departments: ADES STRASBOURG - Tel.: +33 () Departments: (north east) ADES TOURS - Tel.: +33 () Departments: ADES TOUOUSE - Tel.: +33 () Departments: ADES INTERNATIONA - Tel.: +33 () Fax: +33 () Aldes reserves the right to make any changes to its products that are connected with technical developments. - Trade Register of yon RCS VC /214

CYCLONE F 400 smoke extraction casing

CYCLONE F 400 smoke extraction casing Fire protection CYCLONE F smoke extraction casing Presentation of the CYCLONE F range (12) WHY CHOOSE A CYCLONE F? In order to fulfil the requirements of the CE markings (EN 1211-3 and the French governmental

More information

Bap SI. Self-balanced grilles Full range of single and double airflow grilles from 15 to 150 m 3 /h for residential housing and commercial premises

Bap SI. Self-balanced grilles Full range of single and double airflow grilles from 15 to 150 m 3 /h for residential housing and commercial premises Self-balanced grilles Full range of single and double airflow grilles from 15 to 150 m 3 /h f residential housing and commercial premises Bap SI Selection guide Description Advantages Construction Range

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered Comfort ventilation Self-supporting casing with lacquered finish as standard Air intake or exhaust operation Simplified access to internal components ErP READY Air flow: 500 to 35 000 m 3 /h Use ventilation

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design Comfort ventilation Very wide flow rate range: 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing Use ventilation are designed for the ventilation of tertiary or industrial buildings, for

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

Horizontal Cartridge DUST COLLECTOR OPF

Horizontal Cartridge DUST COLLECTOR OPF * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces.

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software

More information

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB) Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features & Benefits In-line, Belt Driven, compact centrifugal twin fan High Quality Heavy Gauge Galvanised Steel Casing Optional IP65 Service Isolator Motor

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION ENGLISH This directions for use contains following products: CK

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

TPAK Series COOLANT PUMP

TPAK Series COOLANT PUMP TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW LOW VOLTAGE WIND CONVERTERS ABB wind turbine converters ACS880, 800 kw to 8 MW 2 ABB WIND CONVERTERS, ACS880 WIND TURBINE CONVERTERS ACS880 wind turbine converter Flexible solution The ACS880 converter

More information

NBE50-250/205 A-F2-A-BAQE

NBE50-250/205 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NBE5-25/25 A-F2-A-BAQE Grundfos pump 9518635 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/9518635/nbe-5-25-25-a-f2-a-e-baqe.html

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

TD-ECOWATT AND DECOR-ECOWATT Series

TD-ECOWATT AND DECOR-ECOWATT Series S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

NB80-160/161 A-F2-A-BQQE

NB80-160/161 A-F2-A-BQQE GRUNDFOS DATA BOOKLET NB8-16/161 A-F2-A-BQQE Grundfos pump 9943539 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/9943539/nbe-125-315-275-as-f2-a-e-bqqe.html

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION TWI FAS TWI SQUIF TECHICAL IFORMATIO TWI SQUIF FAS RU & STADBY SOLUTIO FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIOS. FOR HIGH TEMPERATURE RAGE REFER TO SMOKE SECTIO 264 TWI FAS TWI SQUIF TECHICAL IFORMATIO

More information

BPF. Centrifugal Plug Fans

BPF. Centrifugal Plug Fans BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

TPED /4-A-F-A-BQQE 3X400 50HZ

TPED /4-A-F-A-BQQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPED 125-3/4-A-F-A-BQQE 3X4 5HZ Grundfos pump 98742617 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tped/98742617/tped-125-3-4-a-f-a-bqqe.html

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14 Index A AC motors Mounting position designations... 89 Additional documentation... 12 Add-on encoder cables... 579, 585 Anti-condensation heating... 500 B Backstop... 471 BE brake technical data... 375

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

CRE15-01 A-F-A-E-HQQE 1x HZ

CRE15-01 A-F-A-E-HQQE 1x HZ GRUNDFOS DATA BOOKLET CRE15-1 A-F-A-E-HQQE 1x22-24 5 HZ Grundfos Pump 96512684 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre15/96512684/cre-15-1-a-f-a-e-hqqe.html

More information

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

CRE10-02 A-A-A-E-HQQE 1x HZ

CRE10-02 A-A-A-E-HQQE 1x HZ GRUNDFOS DATA BOOKLET CRE1-2 A-A-A-E-HQQE 1x2-24 5 HZ Grundfos Pump 9651251 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre1/9651251/cre-1-2-a-a-a-e-hqqe.html

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DTP. Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl 8600 AD Sneek, Holland

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

USER MANUAL MPS 1-5KW SERIES

USER MANUAL MPS 1-5KW SERIES USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

Start-up instructions

Start-up instructions E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:

More information

Centriflow Plus EC. Technical data

Centriflow Plus EC. Technical data Technical data Centriflow Plus CTLOGUE Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Inlet cone and supporting frame...5 EC motor...5 ir flow sensor...6

More information

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS Dry Cooler CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene glycol mixture. The coolers

More information

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS HEATING & COOING COI PRODUCTS AIR COOED CONDENSERS Small footprint low profile 6, 8, 10, 12 or 16 pole fan motors Noise levels to ISO 3745 Variable fan speed option HEATING & COOING COI PRODUCTS AIR COOED

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Pure sine wave charger inverter Product Manual

Pure sine wave charger inverter Product Manual Pure sine wave charger inverter Product Manual The inverter installer must be professional, for the high pressure in the inverter, unprofessional person please do not open it. The inverter should be installed

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

WINDER. Impellers with higher efficiency and less sound level

WINDER. Impellers with higher efficiency and less sound level WINDER Impellers with higher efficiency and less sound level Winder Solutions The last new generation impeller With the Serrated Novovent Concept (S.N.C.), NOVOVENT, S.A. has developed a new blades generation.

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

CRE A-F-A-E-HQQE 3x HZ

CRE A-F-A-E-HQQE 3x HZ GRUNDFOS DATA BOOKLET CRE64-2-1 A-F-A-E-HQQE 3x4 6 HZ Grundfos pump 96123995 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cre64/96123995/cre-64-2-1-a-f-a-e-hqqe.html

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

APPLICATIONS. Pumping of clear unfilled liquids in housing, agricultural and industrial sectors.

APPLICATIONS. Pumping of clear unfilled liquids in housing, agricultural and industrial sectors. OPERATING LIMITS Flow rates up to: 34 m 3 /h Head up to: 96 m CL Max discharge pressure: 1 bar Max suction pressure: 6 bar Temperature range: - 15 to +11 C* Max ambient temperature: + 5 C ND of ports:

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit High Efficiency Bidirectional Fan Unit VEX5 (Everest XH) Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information