Horizontal Cartridge DUST COLLECTOR OPF

Size: px
Start display at page:

Download "Horizontal Cartridge DUST COLLECTOR OPF"

Transcription

1 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 3000 Weight kg 900 Number of filtering elements nr 4 Filtering surface m² 84 Number of cleaning valves nr 4 1" - 24 V DC Nominal air flow m³/h 3000 Nominal static pressure Pa 3000 Nominal fan power kw 4 db(a) 76

2 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 3300 Weight kg 1050 Number of filtering elements nr 4 Filtering surface m² 84 Number of cleaning valves nr 4 1" - 24 V DC Nominal air flow m³/h 3300 Nominal static pressure Pa 3340 Nominal fan power kw 5.5

3 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 4400 Weight kg 1200 Number of filtering elements nr 6 Filtering surface m² 126 Number of cleaning valves nr 6 1" - 24 V DC Nominal air flow m³/h 4400 Nominal static pressure Pa 3190 Nominal fan power kw 5.5

4 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 6600 Weight kg 1550 Number of filtering elements nr 8 Filtering surface m² 168 Number of cleaning valves nr 8 1" - 24 V DC Nominal air flow m³/h 6600 Nominal static pressure Pa 3190 Nominal fan power kw 7.5

5 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 8800 Weight kg 1800 Number of filtering elements nr 12 Filtering surface m² 252 Number of cleaning valves nr 12 1" - 24 V DC Nominal air flow m³/h 8800 Nominal static pressure Pa 3920 Nominal fan power kw 15

6 * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF Weight kg 2200 Number of filtering elements nr 16 Filtering surface m² 336 Number of cleaning valves nr 16 1" - 24 V DC Nominal air flow m³/h Nominal static pressure Pa 4280 Nominal fan power kw 18.5

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

series RVV Variable flow rate controllers

series RVV Variable flow rate controllers series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered Comfort ventilation Self-supporting casing with lacquered finish as standard Air intake or exhaust operation Simplified access to internal components ErP READY Air flow: 500 to 35 000 m 3 /h Use ventilation

More information

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm] Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

NCF 60 Hz. Protection class IP 55

NCF 60 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 624 NR. The engineer's choice Product Data Sheet 624 NR Product Data Sheet 624 NR The engineer's choice Product Data Sheet 624 NR 624 NR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data...

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing

More information

Product Data Sheet DV4118 N

Product Data Sheet DV4118 N The engineer's choice DV4118 N INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design Comfort ventilation Very wide flow rate range: 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing Use ventilation are designed for the ventilation of tertiary or industrial buildings, for

More information

Technical Information

Technical Information N 10 October 2010 A fan is a volume revolving machine that aims to move a mass of air. Each fan is specified by an operation curve linking airflow, pressure and speed. These fans curves gives technical

More information

Chilled Water Vertical Fan Coils

Chilled Water Vertical Fan Coils PRODUCT MANUAL Chilled Water Vertical Fan Coils Models: FWMW-C FWMW-H FWCW-C FWCW-H INDEX Vertical Fan Coil page 2 General Characteristics page 3 Technical data page 7 Sound Level page 9 Operating Limits

More information

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Low Power Consumption Fan 60 mm Sq. 10 mm Thick San Ace 60 9GA Type

Low Power Consumption Fan 60 mm Sq. 10 mm Thick San Ace 60 9GA Type New Products Introduction Low Power Consumption Fan 6 mm Sq. 1 mm Thick San Ace 6 9GA Type Tatsuya Midorikawa Toshiyuki Nakamura Naoki Murakami 1. Introduction In recent years, a trend has emerged for

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

Ductable water unit FWD UNT-PRC002-E4

Ductable water unit FWD UNT-PRC002-E4 Ductable water unit FWD 08-1 - 0-0 - 4 UNT-PRC00-E4 Table of Contents General data... Performance data... 4 Cooling capacities... 4 Heating capacities... Water pressure losses... 6 Available static pressure...

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content: LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D05M, E05... 6 D052M, E052... 7 D060, E060... 8 D064, E064... 9 D066, E066... 10 D07, D072...

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 NXHH The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D045M, E045... 6 D05M, E05... 7 D052M, E052... 8 D060, E060... 9 D064, E064... 10 D066, E066...

More information

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB) Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features & Benefits In-line, Belt Driven, compact centrifugal twin fan High Quality Heavy Gauge Galvanised Steel Casing Optional IP65 Service Isolator Motor

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 NXHH The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data 1506A-E88TAG5 293 kwm standby @ 1500 rpm 333 kwm standby @ 1800 rpm 1500 Series Basic technical data Number of cylinders............................................................6 Cylinder arrangement....................................................

More information

Product Data Sheet ACi 4420 MLR

Product Data Sheet ACi 4420 MLR ACi 4420 MLR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5

More information

Product Data Sheet 4184 NGX

Product Data Sheet 4184 NGX The engineer's choice 4184 NGX INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

Product Data Sheet ACi 4420 HHR

Product Data Sheet ACi 4420 HHR ACi 4420 HHR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001 Fan Performance Curves - FDCLP2 with ECM Unit Size 1 1 2 3 4 5 6 7 8 9 1 11 Unit Size 2 1 2 3 4 5 6 7 8 9 1 11 12 No Coil 1 Row 2 Row FDCLP2 Fan Curves-1 v1 Fan Performance Curves - FDCLP2 with ECM Unit

More information

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355. Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw Water terminals from 91 to 1548 m 3 /h SysCoil Comfort Floor and ceiling fan coil units from 0,5 to 9,6 kw from 0,6 to 13,6 kw SysCoil Comfort Innovation for an optimum comfort ErP 2018 TERTIAIRY H 3 /h

More information

Unobox units with backward curved centrifugal impellers

Unobox units with backward curved centrifugal impellers Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);

More information

Product Data Sheet 4414/2H

Product Data Sheet 4414/2H The engineer's choice 4414/2H INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors

More information

HR Combi-line. Heat recovery unit with heat pump on extended AHU base frame. Aluminum anodized Pentapost coldbridge free frame construction

HR Combi-line. Heat recovery unit with heat pump on extended AHU base frame. Aluminum anodized Pentapost coldbridge free frame construction HR ombi-line Heat recovery unit with heat pump on extended AHU base frame High Efficiency > 90% Aluminum anodized Pentapost coldbridge free frame construction Panels 45mm double-walled, color RAL 9002

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

NCF fans 60Hz. Protection class IP 55

NCF fans 60Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Product Data Sheet 8314 HR-197

Product Data Sheet 8314 HR-197 The engineer's choice 8314 HR-197 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK Technical Data 4000 Series Diesel Engine - ElectropaK Basic technical data Number of cylinders..................................................... 8 Cylinder arrangement.............................................

More information

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315 Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

FEATURES & BENEFITS UPON REQUEST

FEATURES & BENEFITS UPON REQUEST ErP 27 IDUSTRIAL CETRIFUGAL FAS WITH VERY HIGH PRESSURE APPLICATIO High pressure industrial centrifugal fans with backward curved impeller, suitable for exhausting clean or slightly dusty air. They can

More information

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and

More information

METRIC VECO SYNCHRO BELTS Selection of Transmission / 6

METRIC VECO SYNCHRO BELTS Selection of Transmission / 6 12008-1 / 6 Drive Characteristics - Motor specifications Pm - installed Power kw Nm - motor speed rpm - shaft diameter mm - driver machine Pa - power to transmit kw Nr - speed of driven machine U/min -

More information

Continuous Baseload. Prime Power

Continuous Baseload. Prime Power Technical Data 4000 Series Diesel Engine - Electrounit Basic technical data Number of cylinders..................................................... 8 Cylinder arrangement.............................................

More information

product specification

product specification 4414 ML Customer specification: No Version: 1.0 Created: 16.09.2011 INDEX 1 General... 2 2 Mechanics... 2 2.1 GENERAL... 2 2.2 MOTOR... 2 2.3 CONNECTIONS... 3 3 Operating Data... 4 3.1 OPERATING DATA -

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

Product Data Sheet 3214 JH3-195

Product Data Sheet 3214 JH3-195 3214 JH3-195 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 6

More information

Rooftop packaged Units

Rooftop packaged Units Rooftop packaged Units Standard Range 10.2kw-105kw; Special design: 122kw-210kw; R22,R407c,R410a all available; T3 conditioners available; NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 8412 N/ The engineer's choice The engineer's choice 8412 N/12-252 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output...

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION 1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 40 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 35.4 inches 21 gal 90 rpm 12 50 rpm 300 540 inches

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION 1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 gal 132 rpm 12 50 rpm 300 540 inches 20 SOLVENT

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0) Features: FONTECK INDUSTRIES AFBD AXIAL FAN (ATEX Certified, Gas Group IIB+H2) ATEX certified Comply with standard: EN 14986, EN13463 1 Driven directly by ATEX certified motor 15 sizes with case opening

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

CHMT Series, F Rated Fans

CHMT Series, F Rated Fans CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke

More information

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology Slim Ducted Systems Two choices of selection for the air inlet flow Natural drain discharge port and drain pump (up to 850 mm) Cleanable pre-filter included Slim Ducted Systems Digital Inverter Four steps

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC axial fan. sickled blades (S series) Wall ring with guard grille W4E3-DN2-39 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County

More information

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 4118 N/ The engineer's choice The engineer's choice 4118 N/12-190 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92 and 5.9) Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9") 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344

More information

Product Data Sheet 8412 NHU-519

Product Data Sheet 8412 NHU-519 The engineer's choice 8412 NHU-519 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice Product Data Sheet 4184 N/17X The engineer's choice 4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 614 N/2HH-169 The engineer's choice The engineer's choice 614 N/2HH-169 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical

More information

Product Data Sheet 632 NU-006

Product Data Sheet 632 NU-006 The engineer's choice 632 NU-006 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

Transformer Oil Cooling Solutions

Transformer Oil Cooling Solutions pumps and fans Transformer Oil Cooling Solutions Series NTG/ TG/ TGCL Pumps TF/ TFBR/ NTF/ VTTF Fans quality certificate INDEX The company Portfolio Development PUMPS Nomenclature Inline axial pumps NTG

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

09GDV and 09LDV. Air Cooled Dry coolers and Condensers Air Cooled Dry coolers and Condensers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 09GDV and 09LDV Nominal cooling

More information

4016TAG1A 4016TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Ratings. Basic technical data

4016TAG1A 4016TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Ratings. Basic technical data 4016TAG1A 1270-1741 kwm (Gross) @ 1500 rpm 1413-1937 kwm (Gross) @ 1500 rpm ElectropaK Basic technical data Number of cylinders...................................................16 Cylinder arrangement..........................................

More information