Instrumentation Catalog
|
|
- Opal Flora Long
- 6 years ago
- Views:
Transcription
1 Instrumentation Catalog
2 INSTRUMENTS Current Meters... 3 Earth Ground/Resistance... 3 Fault Locator... 4 Insulation Testers/HIPOT... 4 Network... 6 Power Quality Analyzer Pressure... 8 Process/Loop Calibrators... 8 Temperature and Humidity... 9 Transformer/Relay Testers.. 10 Vibration Testers HOURS OF OPERATION 7:00am - 5:00pm (MST) Monday - Friday Closed Saturdays and Sundays 24 hour on call service available
3 CURRENT METERS Fluke 381 Remote Display True RMS 1000 AC/DC Clamp Meter, 2500A AC with Flexi CT EARTH GROUND / RESISTANCE Earth Ground/Resistance Current Meters Fluke or 4 Pole Earth Ground Resistance Kit Fluke 1630 Earth Ground Clamp Resistance Equipment & Operator Training Equipment Operator Training is a Win-Win Solution. Contact The Cat Rental Store today for courses and details
4 Fault Locator FAULT LOCATOR Radiodetection RD8000 Pipe, Cable and RF Marker Locator Magnawand ID2100 Professional Ferrous Metal Detector IUP Fault Wizard Primary Underground Cable Fault Locator Rigid SeekTech SR-20 Primary Underground Cable Fault Locator INSULATION TESTERS / HIPOT Fluke 1550C & kV/10kV Insulation Resistance Tester Kit Megger MIT kV Insulation Resistance Tester Kit 4 The Cat Rental Store Wirtanen Electrial Division
5 INSULATION TESTERS / HIPOT Fluke V Insulation Resistance Tester Megger CB100 Low-Voltage Capacitance and Insulation Power Factor Test Set Insulation Testers/HIPOT HV Diagnostics HVA60 Universal High Voltage Test System Megger CFL510G Time Domain Reflectometer HV Diagnostics TD60 Wireless Tan Delta Cable Diagnostic The Cat Rental Store Wirtanen Electrial Division 5
6 Network NEW ARRIVAL 2000A and 3000A Distribution Panels Accepts F,H,J,K,L,M,P frame I-Line breakers Series 16 Cam lock\ Hardwire options Large 23 Breaker Capacity Mounted in a Steel Frame with Lifting Eyes and Fork pockets NETWORK Fluke DSX 5000 Ethernet Cable Tester 10 Gigabit 6E Fluke DTX 1800 Ethernet Cable Tester Kit Copper Fluke DTX 1800 kit Ethernet Cable Tester Kit Fiber 6 The Cat Rental Store Wirtanen Electrial Division
7 POWER QUALITY ANALYZER Fluke Phase Power Quality Analyzer Fluke Phase Power Logger with 3000 A Flexi-CTs Power Quality Analyzer Fluke 435 Series II 3 Phase Power Quality Analyzer Fluke Phase Power Quality Recorder Fluke Phase Electrical Energy Logger The Cat Rental Store Wirtanen Electrial Division 7
8 Pressure Process / Loop Calibrators PRESSURE Fluke 700P Pressure Module Crystal Engineering Vision Portable Reference Pressure Recorder PROCESS / LOOP CALIBRATORS Fluke 754 Documenting Process Calibrator with Hart Communication Fluke 709H Hart Loop Calibrator Fluke ma Process Clamp Meter Fluke 725 Multifunction Process Calibrator 8 The Cat Rental Store Wirtanen Electrial Division
9 TEMPERATURE AND HUMIDITY Fluke Ti x Hz Industrial Thermal Camera with a Temperature Range of -20 C to 1200 C Temperature and Humidity Fluke C Accuracy 50 C to 650 C Portable Field Dry Well SUBSCRIBE AND RECEIVE exclusive deals, promotions and giveaways courtesy of The Cat Rental Store. SIGN-UP TODAY, and become a member of the most exclusive club in the equipment industry. The Cat Rental Store Wirtanen Electrial Division 9
10 Transformer / Relay Testers TRANSFORMER / RELAY TESTERS Vanguard Auto ohm 200 High Current True DC Micro-ohmmeter Vanguard TRM-40 Transformer Winding Resistance Meter Vanguard ATRT-03 3 Phase Transformer Turns Ratio Tester Omicron CMC 356 Relay Test Set and Commissioning Tool Vanguard EZCT-2000C Plus Current Transformer Tester SMC Mentor 12 3 Phase Relay Test Set 10 The Cat Rental Store Wirtanen Electrial Division
11 TRANSFORMER / RELAY TESTERS SMC Raptor Current Injection Test Set Primary Current Injection Test Set VIBRATION TESTERS ISA BTS 200 Battery Test System, Battery Test System 130A Discharge, up to 260A with Slave Transformer / Relay Testers Vibration Testers Fluke 805 Portable Vibration Meter Pen Fluke 810 Portable Vibration Tester The Cat Rental Store Wirtanen Electrial Division 11
12 U n i t Yukon Juneau Northwest Territories Yellowknife British Columbia High Level Fort St. John Dawson Creek Alberta Peace River Fort McMurray Fort McKay Terrace Prince George Grande Prairie Wabasca Slave Lake Bonnyville Hinton Edmonton Lloydminster Kamloops Saska Vancouver Langley Calgary U n i t e d S t a EDMONTON Avenue, Edmonton, Alberta, T5L 3B2 (780) Fax: (780) t e s o f A catrents.ca
instrumentation test and measurement
Cable & Core Identifiers 3 3 3 HV De-energised 3 phase 3 3 LV 3 Phase and Single Phase 3 3 LV Live Phasing Identification HV and LV 3 3 Cable Fault Location (Underground) 3 3 3 3 3 3 3 3 Cable Sniffer
More informationWe are engaged in manufacturing, supplying and trading Testing & Measuring Instruments (Electrical, Control & Instrumentation) Work Benches,
We are engaged in manufacturing, supplying and trading Testing & Measuring Instruments (Electrical, Control & Instrumentation) Work Benches, Temperature, Pressure & Marine Calibrator Kit, Thermal Imagers
More informationANAUM INTERNATIONAL ELECTRONICS LLC. Test and Measurement Calibration Services Test Bench.
ANAUM INTERNATIONAL ELECTRONICS LLC Test and Measurement Calibration Services Test Bench www.anaum.ae About Us Located in the Musaffah, Abu Dhabi, United Arab Emirates, Anaum International Electronics
More informationPRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY
Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationTEMPERATURE RISE TESTS
CP No.: CP0511 Rev. 01 Page: 1 of 6 CERTIFIED TEST REPORT TEMPERATURE RISE TESTS Type CMU Power Fuses REV. 01 DATE: August 12, 2005 ORIGINAL REPORT DATE: May 25, 2005 Cooper Power Systems, Inc. CP No.:
More informationELE-PT-E-2005 Electrical Testing & Protection Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS
102926-ELE-PT-E-2005 Electrical Testing & Protection Engineer Holds B. Sc. and M. Sc. in Electrical Power & Machines Engineering and has about 9 years hands-on experience in protection, testing and commissioning.
More informationCOMPANO 100. Primary injection, secondary injection and basic protection test set
COMPANO 100 Primary injection, secondary injection and basic protection test set Multifunctional device for basic testi Challenging commissioning and recommissioning tasks During commissioning of protection
More informationBaker PPX Power Packs
Baker PPX Power Packs High voltage motor testing made easy for motor manufacturers, repair shops and plant maintenance. The Baker PPX30 Power Pack shown in combination with the Baker AWA-IV static electric
More informationAccident, Maryland, USA
BUCKET INSULATION TUCK MATEIALS MOTO CICUIT BEAKE POTABLE VACUUM INTEUPTE GENEATO G GIS POTECTIVE EQUIPMENT ECLOSE SWITCHGEA Accident, Maryland, USA www.phenixtech.com +1.301.746.8118 Phenix Technologies
More informationInstrument Identification. Customer Instrument ID: S Order #: Calibration Standards TIMER CURRENT
Printed on: 3/18/2016 - OMNIA 8200 SERIES 6IN1 BASE UNIT Technician: Power ATS2_XATS7 Certificate of Calibration Customer Instrument ID: S12524 Order #: 0247337 Calibration Standards Certificate Number
More informationSwitchgear and Distribution Systems for Engineers and Technicians
Switchgear and Distribution Systems for Engineers and Technicians WHAT YOU WILL LEARN: How to identify typical characteristics of an industrial distribution system Become familiar with the main components
More informationMIT515, MIT525, MIT1025, MIT1525
MIT515, MIT525, MIT1025, MIT1525 Measures up to 30 TΩ Safety rated up to CAT IV 1000 V to 3000 m Unique dual-case design - additional user protection Operates from battery or a.c. mains supply Rapid charge
More informationFor all of your Ground T esting needs. Technical Hotline: (800) Ground Testers
For all of your Ground T esting needs Technical Hotline: (800) 343-1391 www.aemc.com Ground Testers Ground Testers Understanding Ground Resistance Testing The term ground is defined as a conducting connection
More informationASEC scope of work and services can be classified as
Electromechanical, electronic and telecommunication contracting, maintenance and technical support projects ASEC scope of work and services can be classified as ASEC services can be broadly classified
More informationELE-CMS-E-2007 Electrical Project Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS
103313-ELE-CMS-E-2007 Electrical Project Engineer Holds a B. Sc. in Electrical Power & Machines Engineering and has about 10 years hands-on experience working in construction, commissioning and maintenance.
More informationCatalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec
Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif
More informationADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE
ADVISE DESIGN FOR ELECTROTECHNICAL EXCELLENCE IMPLEMENT ADVISE DESIGN FOR ELECTROTECHNICAL EXCELLENCE Gemitech was founded in 1990 and, in just a few short years, grew to be recognized as medium and IMPLEMENT
More informationSolid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16
Solid Dielectric, Independent Pole Operated Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 38kV, 800A continuous current, 12.5kA symmetrical
More informationApproximately 13 years experience in H.V and L.V projects, 9 years in Egypt and two years in Emirates and two year in SAUDI ARABIA
EL-PT0-E-0083-1994 Testing and Protection Engineer Approximately 13 years experience in H.V and L.V projects, 9 years in Egypt and two years in Emirates and two year in SAUDI ARABIA PERSONAL DATA: Nationality:
More informationSYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)
ANNEXURE I SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test) Paper I & Paper II for General Category of S.C.C. Examination Paper I & Paper
More informationHIGH POWER MOTOR TEST SYSTEMS
HIGH POWER MOTOR TEST SYSTEMS Model MTS1000R-750 AC/DC Motor Test System 50102 VISION PHENIX Technologies is recognized the world over as the leading manufacturer of Motor Test Systems. For over twenty
More informationCompressor Automation Solutions. For. Safety + Environment + Optimization
Compressor Automation Solutions Power Ignition and Controls a division of Spartan Controls For Safety + Environment + Optimization REMVue - 500 Plus Hi Spec Applications Emissions and Fuel Reduction Performance
More informationBellMega BM-510. Operation Manual Ver: 1.0 Rev: 1
BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for
More informationKnowledge Evaluation
Knowledge Evaluation Instructor Information: The following knowledge evaluation can be used to determine if a person has an adequate level of knowledge and understanding of hours of service requirements.
More informationAlberta s Third Party Auditor Certification Program. Testing Your Knowledge at the Third Party Auditor Interview Stage
Part One: Alberta s Third Party Auditor Certification Program Testing Your Knowledge at the Third Party Auditor Interview Stage For questions 1 4, circle the correct answer (answers may be found at the
More informationAccident, Maryland, USA
CABLE CIRCUIT BREAKER MOTOR GENERATOR G GIS SWITCHGEAR RECLOSER PROTECTIVE EQUIPMENT INSULATION PORTABLE MATERIALS Accident, Maryland, USA www.phenixtech.com +1.301.746.8118 Phenix Technologies Phenix
More informationReference Manual. UH28C High Voltage Tester
Reference Manual UH28C High Voltage Tester Preliminary Remarks : Check if the delivery is complete. Take care about probably small parts (plugs etc.). Check for transportation damage, probably not all
More informationSome of the shows are close to capacity and existing Exhibitors will be given first choice on their space until Jan 31, Please book early!
HUNT MANIA SHOW PRODUCTIONS a Division of All-Rite Auctions PO BOX 678, DAYSLAND, AB T0B1A0 2019 HUNT MANIA SHOWS SCHEDULE AND PRICING Dear Exhibitor, Here is the 2019 Schedule. We are excited to add PRINCE
More informationEARTH RESISTANCE DET24C
EARTH DET24C 1 AUTOMATED NUMBER OF TESTS: 1 SERIAL NO. CURRENT A TIME FILTER on/off INSTRUMENT SERIAL NO. TEST NOTES REVISED 9/4/2013 INTERSECTING CURVES 2 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL
More informationDunvegan Hydroelectric Project. For Glacier Power Limited. Preliminary Interconnection Study
` Dunvegan Hydroelectric Project For Glacier Power Limited Preliminary Interconnection Study Prepared by Pung Toy, P. Eng. and Ata Rehman, P. Eng. September 24, 2004 Table of Contents Table of Contents...
More informationELE-CMOS-E-2004 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS
100403-ELE-CMOS-E-2004 Electrical Engineer Holds a B. Sc. in Electrical Power & Machines Engineering and has about 10 years hands-on experience working in operation, construction, commissioning and maintenance.
More informationCHAPTER 4 PROTECTION REQUIREMENTS
CHAPTER 4 PROTECTION REQUIREMENTS CHAPTER 4 PROTECTION REQUIREMENTS 4.1 General Means of protection for automatic disconnection against phase and earth faults shall be provided on the customer main switch.
More informationMESG 12 / 17.5 / 24 / 36 KV
MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL
More informationS1-568, S1-1068, S1-1568
S1-568, S1-1068, S1-1568 Resistance range up to 35 TΩ 8 ma noise rejection plus 4 filters Safety up to CATIV 1000V to 4000 m Rapid charge Li-ion battery meets IEC62133 Operate with flat battery from an
More informationSolid Dielectric, Three Phase Reclosers CATALOG VS11
Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance
More informationMIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers
Measures up to 10 TΩ or 20 TΩ () PI, DAR, DD, SV and ramp test Improved productivity operate from line power/mains if battery dead Li ion battery - extended capacity, rapid charge Advanced memory with
More informationMJÖLNER 200 Microhmmeter
Fully automatic testing Micro processor controlled Safe test DualGround and Remote control True DC ripple free current Lightweight suitcase withstands the impact of water, dust or sand Built in thermal
More informationInstallation & Operation Manual
EDL175 Portable Event & Data Logger-Extended Range Installation & Operation Manual BG0447 REV. A3 LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument
More informationMIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kv DC Insulation Resistance Testers
,,,, Measures up to 40 TΩ PI, DAR, DD, SV and ramp test Improved productivity operate from line power/mains if battery dead Li ion battery - extended capacity, rapid charge Advanced memory with time/date
More informationAKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN
Instruction Manual AKM 345 Gen2 Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35 Document ID: IST-103-1-EN www.qualitrolcorp.com (IST-103-1-EN) Legal Information
More informationCase Study on On EHV Circuit Breaker Flashover NTPC-SINGRAULI
Case Study on On EHV Circuit Breaker Flashover AUTHORS: B. K. SINGH (AGM-ELECT) S.C.SINGH (SUPDT-ELECT) MANOJ SHARMA (Dy SUPDT-ELECT) ANAND PANDEY (ENGR-ELECT) BREAKER-FLASHOVER There has been a rising
More informationGround Resistance Tester Model 3620 & 3620 Kits
Ground Resistance Tester Model 3620 & 3620 Kits Model 3620 shown in standard soft carrying case Catalog #2114.90 The Analog Ground Resistance Tester Model 3620 performs ground resistance measurements from
More informationPower Metrics International INC Richmond Terrace Staten Island, NY 10302
Synopsis In the following case study, a poultry processing plant with 7 SP1000 (predecessor to SP2000) units installed experienced monthly reductions in their electricity consumption ranging from 12.5%
More informationRUS accepted Catalog O-vst18
Solid-Dielectric, Independent Pole Option Recloser Providing electronic overcurrent protection for single or three phase operation on systems rated through 38kV, 800A continuous current, 12.5kA or 16kA
More informationAIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE
AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly
More informationMOM2 Handheld High Current Micro-ohmmeter
MOM2 Micro-ohmmeter Up to 240 A Bluetooth headset for audible pass/fail testing against adjustable limits Battery powered Handheld, lightweight 2.2 lb (1 kg) Safe test DualGround Auto range: 1 µω to 1000
More informationUtilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications
G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications Contents 1. Laboratory Objective... 4 2. MECHANICAL OPERATION TESTS... 4 2.1 Purpose... 4 2.2 Procedure... 4 2.3 Results...
More informationCONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES
ECT-4 DATASHEET CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES Excellent mobility Single handed operation Extended operating time Three discrete current injection levels Continuous & pulsed
More informationDELTA4000 Accessories
DELTA4000 Accessories TESTING LARGE SPECIMENS Resonating Inductor The resonating inductor expands the capacitance range of the DELTA automated insulation power factor test sets. The resonating inductor
More informationALLMAC Electrical Eng. 61 (0) Advanced Infrared +61 (0) BES (Aust) Pty Ltd AUSTPTA
page 1a ABB Australia 1800 222 435 Advanced Infrared +61 (0)425 758 820 ALLMAC Electrical Eng. 61 (0)419 819 756 Ampcontrol 1300 267 373 AUSTPTA www.austpta.asn.au BES (Aust) Pty Ltd 61 2 9686 4811 Products/
More informationElectrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II
135 05-1 Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART II TURBINE-GENERATOR: rhipping AND ALARM CIRCUITS i.o' I titrodljction Following on from Lessons 135.03-1 and 135.04-1,
More informationRTD CALIBRATOR Mode KM-CAL-720
An IS 9001:2008 Company RTD CALIBRATR Mode KM-CAL-720 SPECIAL FEATURES : Sources and measures 7 RTD types devices (PT10, PT50, PT100, PT200, PT500, PT1000 (385), PT100 (JIS)) or High accuracy maximum up
More information5 kv and 10 kv Insulation Resistance
S1-552/2 and S1-1052/2 5 kv and 10 kv Insulation Resistance Testers n CAT IV 600 V n Mains or battery powered n Digital/analogue backlit display n Variable test voltage from 50 to 5000 or 10,000 V n Automatic
More informationPretest Module 29 High Voltage Unit 1
Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationATLV MaxSG. Low Voltage Metal Enclosed Switchgear
ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,
More informationHigh Voltage Technology & Testing
The Power of Trust. The Future of Energy. HIGH VOLTAGE TESTING Qualification testing, condition assessment, and forensic analysis Manufacturers and utility users of high-voltage electrical equipment face
More informationWelcome to Garber C O R P O R AT E O V E R V I E W
CORPORATE OVERVIEW Garber Metrology is one of the only companies in the Mid-Atlantic Region that combines full service weighing solutions, a wide range of calibration /metrology services and a broad scope
More informationS1 Series. 5-kV and 10-kV Insulation Resistance Testers. S1 Series 5-kV and 10-kV Insulation Resistance Testers
S1 Series CAT IV 600 V safety rating Line supply or battery operated Noise rejection (2mA or 4mA rms@200v and above) for use in high voltage substations or switchyards 5mA output current provides fast
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationDawson DDM190D. Digital Multimeter User s Manual
Dawson DDM190D Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION...
More information2018 Residential Solar Grid-Tie Catalogue September Issue
2018 Residential Solar Grid-Tie Catalogue September Issue Generating Electricity for a Sustainable World Grid-Tie System in Vernon, BC A+ www.ipwr.net #101-2387 Dominion Rd West Kelowna, BC Canada V1Z
More informationSeptember 2008 TEC, INTELLIGENT MONITORING SYSTEM
September 2008 TEC, INTELLIGENT MONITORING SYSTEM ABB BU Transformers - 1-10/9/2008 TEC, philosophy ABB BU Transformers - 2 - TEC was launched by ABB in year 2002 to improve transformers performance. More
More informationSwitchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable
www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationDate Dash-Canada. Welcome to Date Dash-Canada, the board game that tests your knowledge of Canadian history!
Welcome to, the board game that tests your knowledge of Canadian history! Date Dash is a multiple-choice game designed to test your knowledge of history. In Date Dash- Canada, the goal is to be the first
More informationPORTABLE PRODUCTS for Field Testing High Voltage High Current High Power Test Systems and Components
PORTABLE PRODUCTS for Field Testing High Voltage High Current High Power Test Systems and Components WWW.HUIBERS.INFO 2 PORTABLE PRODUCTS FOR FIELD TESTING PORTABLE PRODUCTS for FIELD TESTING PHENIX Technologies
More informationTHERMOCOUPLE CALIBRATOR Mode KM-CAL-710
An ISO 9001:2008 Company THERMOCOUPLE CALIBRATOR Mode KM-CAL-710 Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple
More informationINTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter
INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Digital Ground Resistance Tester Model 4610 & 4610 Kits 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com
More information2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol
04-62-70001 4 WD NISSAN PATROL STATION WAGON SGL, 4500 cc 2 Unit Petrol Engine 04-62-70002 Spare parts kits for 4 WD Nissan Patrol 4 Set Station Wagon 04-62-70003 Belt-Fan 11720-03J00 4 Each 04-62-70004
More information2019 Residential Solar Grid-Tie Catalogue April Issue
2019 Residential Solar Grid-Tie Catalogue April Issue Generating Electricity for a Sustainable World Grid-Tie System in Vernon, BC www.ipwr.net #101-2387 Dominion Rd West Kelowna, BC Canada V1Z 2Y4 Phone:
More informationApplication note. The APM-AMP meter can be connected in three different configurations:
Application note Title: Current sensing with an APM-AMP meter Date: 5 th September 2014 Revision: 1.0 Introduction: The APM-AMP meter can measure both AC and DC currents. The APM-AMP meter performs automatic
More informationMedium Voltage Test Report Job Number Job Information. Test Information. Circuit Breaker Information. Electric Power Systems
Medium Voltage Test Report Job Number 26960 age 1 of 3 Date 1-23-14 Job Information Customer Electric ower Systems Test Information Test Location Gainesville, TX Test Condition As Left Temperature ( F)
More informationSwitchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable
Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue
More informationFLUID CONTAINMENT AND CONTROL SPECIALISTS SINCE
FLUID CONTAINMENT AND CONTROL SPECIALISTS SINCE 1967 CANFLEX METALLIC GASKETS CANFLEX Spiral Wound Gaskets Manufactured in Accordance with ASME B16.20 Spiral wound gaskets made with an alternating combination
More informationQ&A FOR Webinar on Electrical Basics & Boiler Wiring
Q&A FOR Webinar on Electrical Basics & Boiler Wiring 4-20-16 Q: Is a dual fuel burner flame guard system more complicated than the one you showed us today? A: Not really. If the boiler is equipped for
More informationVoltageTester& PhasingOut
VoltageTester& PhasingOut. Deviqefor 11& 33kV Systems.. "",- OPERATING AND MAINTENANCE INSTRUCTIONS EDGCUMBE INST~UMENTS LIVE LINE TEST EQUIPMENT INSTRUCTIONS FOR USE General The equipment is designed
More information24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)
M6 24kV Medium Voltage Switchgear MetalEnclosed (LSC2A) GENERAL FEATURES GENERAL DESCRIPTION The structure of the cubicles, of considerable strength, has selfsupporting structure and is made of steel sheet
More informationDIGITAL EARTH RESISTANCE Model KM 2030
An ISO 9001:2008 Company GENERAL SPECIFICATIONS : DIGITAL EARTH RESISTANCE Model KM 2030 Display : 3½ Digit LCD display. Ground resistance measurements from 0 ~ 01Ω to 2000Ω with 0.01Ω resolution. Earth
More informationTI23 Pre-Instructional Survey
TI23 Pre-Instructional Survey Name: Date: 1. Identify the balloon contents that represent the relationship between the three electrical measurements as they relate to Ohm s Law. 2. Which of the statements
More informationThe High Power Stack Horizon
Voltage Supply 480-600-690V Current Rating from 150 to 2100A Designed to drive 1-2-3 Phase Loads Internal Fuse with Micro for Fuse Failure Stall Fan Protection for 1100 to 2100A Control Board with Plug
More informationTrue RMS Autoranging Multimeter
Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationCobra-S. Catalog Cobra-S
Cobra-S Solid Dielectric, Three Phase Reclosers Providing electronic three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5/16kA symmetrical interrupting Control
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) MOM2 MOM2 Micro-ohmmeter Up to 240 A Bluetooth headset for audible pass/fail testing against adjustable limits Battery
More informationSolid Dielectric, Three Phase Reclosers Catalog O-vs18
Solid Dielectric, Three Phase Reclosers Providing electronic three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance
More informationSolid Dielectric, Triple Option Reclosers Catalog O-vst14
Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting
More informationMotor Protection With The MonitorPro
Motor Protection With The MonitorPro This application note can show you the easy way to protect your motors and your pump stations. The MultiTrode MonitorPro can protect your motors from a wide range of
More informationSOLAR TRAINING ACADEMY
5 Day Solar PV Workshop Most comprehensive workshop in the market is designed to provide detailed renewable energy systems theory with detailed calculations and hands-on practical. Focus is photovoltaic
More informationrefurbishment and services
page 1a ABB Australia 1800 222 435 AEMC Instruments export@aemc.com Ampcontrol 1300 267 373 Arthur D. Riley 64 4 472 7614 AVO New Zeal 0800 485 990 AVT Services 1800 559 988 Central Test 61 3 5445 6220
More informationService. Reliable Switching of Higher Voltage Current h Hotline: Service NORTH Service East
Reliable Switching of Higher Voltage Current Service 24 h Hotline: Service NORTH +49 172 1558379 Service East +49 160 93439789 www.szm-gmbh.de Productbrochure Service-2016_01 Our Services Bad Muskau has
More informationMEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW
MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationSafe, fast HV circuit breaker testing with DualGround technology
Safe, fast HV circuit breaker testing with DualGround technology Substation personnel safety From the earliest days of circuit breaker testing, safety of personnel has been the highest priority. The best
More informationINSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT
CM69 TRMS AC EARTH LEAKAGE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationBC Hydro System 2016 Annual Progress Report
March 11, 2016 Philip Augustin, P.E. Chair, Technical Studies Subcommittee 503-464-7783 philip.augustin@pgn.com Mr. Enoch Davies WECC Technical Staff 155 North 400 West, Suite 200 Salt Lake City, UT 84103-1114
More informationLarge Air Cooled Generator Failure
Large Air Cooled Generator Failure Henry Tarnecky AVP - Sr. Engineering Specialist, FM Global 2017 IRIS Rotating Machinery Conference FM Global Basics Commercial/Industrial Property Insurer Mutual Co.,
More informationSECTION DC POWER SUPPLY/BATTERY CHARGER
SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More information