3-way flow control valve type UDUE10 is intended for

Size: px
Start display at page:

Download "3-way flow control valve type UDUE10 is intended for"

Transcription

1 3-way flow control valve type UDUE10 NS10 up to 35 Ma up to 50 dm 3/min DT SHEET - OER RTION MNU NUL WK LICTION 3-way flow control valve type UDUE10 is intended for independent from pressure on supply side of (pump) setting flow rate in hydraulic system. It enables to control speed movement of receiver - mostly piston rod or hydraulic motor. Supply stream (port ) is divided on priority stream directed to port and residual discharged by port B to reservoir or supply other receiver. DESCRITION OF OERTION UDUE10-22/ B(Q B) (Q ) 5 (Q ) The principle of regulator operation is achieved by division of supply stream (port ) on priority stream directed to port and residual stream (port B). 3-way regulator type UDUE10 consists of two principal valves: throttle and differential. Throttle valve act as measuring and consists of choke (1) made in form of poppet valve and setting (2). Differential valve acts as regulator and consists of spool (3) and spring (4). Hydraulic fluid flowing through the valve from port to causes drop of pressure on choke (1), which depends on setting and current flow value through choke (1). ressure difference before and after choke (1) acts on spool (3) and after overcoming spring preload (4) causes opening the way from port to B enabling residual stream flow. Spool (3) gets position of balance at the moment when pressure drop on measuring throttle (1) is corresponding to spring preload (4). It means that stream value flowing through port is constant, independent from pressure on supply side (port ), and is dependent only on position of regulator setting. Regulator is equipped with check valve (5), enabling free flow from port to. Type UDUE WK

2 TECHNICL DT Hydraulic fluid Required fluid f clec leanline ness classc Nominal fluid viscosity Viscosity range Fluid temperature range (in a tank) mbient temperature range Max operat ating pressure Min operating pressure Nom ominal l flow(prif prior ority stream) Q Max x flow(suppf upply streams tream) Q Weight mineral oil ISO 4406 class c 20/18/15 2 o 37 mm /s at temperature 55 C 2 2,8 up to 380 mm /s recommended max o -20 oc up to +70 C 35 Ma 0,5 Ma 50 dm 3 /min 70 dm 3 /min 2,3 kg o o 40 C up to 55 C o o -20 C up to +70 C INSTLLTION ND OERTION REQUIREMENTS 1. During the operation one must maintain the recommended fluid viscosity and provide proper filtration specified in this Data Sheet S - Operation Manual. 2. In order to ensure safe and failure-free free operation of the valve, the following must be checked: operation of the valve cleanliness of the hydraulic fluid 3. In order to provide proper tightness of the valve connection to a hydraulic system, one should ensure tightening torque and valve operation parameters as a s specified in this Data Sheet - Operation Manual. 4. person operating the valve must be familiarized with the content of this Data Sheet - Operation Manual. SCHEMES Graphic symbol of flow control valve type UDUE10... B WK Type UDUE10

3 OVERLL ND CONNECTION DIMENSIONS valve ve type UDU U DUE , ,4 G1/2 65 B = 68 G3/4 = = = O11depth 7-4 depth holes O7-4 holes S 32 O ,5 G1/ thre hreaded connect c nections s,, B 90 OD1 OD2,, B L T dimension φd1 L thre hreaded connect c nection, B G 3/4 G 1/ φd2 T 36 0,5 34 0,5 Type UDUE WK

4 ERFORMNCE CURVES Char aracter acterist stics of f regulat ation range r 2 o measured at viscosity ν = 41 mm /s and temperature t = 50 C Q [dm 3 /min] Characteristic of priority discharge effect Q (port ) from position of setting knob (scale) for valve typeud UDUE10... for flow rate on supply side (port) Q = 70 dm 3 /min positi sition of settin tting knob[scale] Flow char c aracter acterist stics 30 Characteristic of dependence priority discha rge effect Q from pressure changes on receiver p (port ) Q 3 [dm /min] p [Ma] WK Type UDUE10

5 HOW TO ORDER UDUE 10 Nominal size (NS) NS10 =10 * Series number (20-29) - connection and installation dimensions unchanged = 2X series 22 = 22 Flow range acc. to characterictics- page 4 = 50 Type of setting element knob with scale(1 turn) =4 Further requirements in clear text (to be agreed with the manufacturer) NOTES: Flow control valve should be ordered according to the above coding. The symbols in bold are preferred versions in short delivery time. Coding example: UDUE10-22/50-4 Type UDUE WK

6 EXMLE OF LICTION IN HYDRULIC SYSTEM UDU DUE B ONR Wadowice S.. ul. Wojska olskiego Wadowice tel fax WK Type UDUE10

DESCRIPTION OF OPERATION

DESCRIPTION OF OPERATION Valve cover with a function of controlling closed position of the valve poppet type ULZS ED NS6, 5 up to 0 MPa up to 00 dm /min DT SHEET - OPER RTION MNU NUL WK 6 60 0.07 PPLICTION The valve cover with

More information

Directional control valves hydraulically operated type WHG6/WHP6

Directional control valves hydraulically operated type WHG6/WHP6 LICION Directional control valves hydraulically operated type WHG6/WH6 Directional control valves hydraulically operated type WHG6, WH6 are intended for change in direction of fluid flow in a hydraulic

More information

Pressure relief valve, pilot operated, sandwich plate type UZPR10

Pressure relief valve, pilot operated, sandwich plate type UZPR10 ressure relief valve, pilot operated, sandwich plate type UZR0 NS0 up to,5 Ma up to 00 dm /min WK 497 00.0 LICION ressure relief valve, pilot operated, sandwich plate design type UZR0 0 is used to limit

More information

2/2 - way cartridge valve type URZS/S

2/2 - way cartridge valve type URZS/S / - way cartridge valve type URZS/S NS, 0, 50 up to MPa up to 00 dm /min DT SHEET - SERVICE MNU NUL WK 1 0 07.01 PPLICTIN / way cartridge valve type URZS S can be used in hydraulic systems as a pilot operated

More information

WK Proportional pressure reducing valve, cartridge design type WZRS6. NS 6 up to 5 MPa up to 40. dm /min APPLICATION DESCRIPTION OF OPERATION

WK Proportional pressure reducing valve, cartridge design type WZRS6. NS 6 up to 5 MPa up to 40. dm /min APPLICATION DESCRIPTION OF OPERATION Proportional pressure reducing valve, cartridge design type WZRS6 NS 6 up to 5 MPa up to 40 dm /min WK 499 979 04.201 PPLICTIN Proportional pressure reducing valve, electrically operated type WZRS6 is

More information

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION Electrically operated directional spool valve with a soft-shift function type WE6 NS6 up to 35 Ma up to 80 dm 3/min D SHEE - OER RION MNU NUL WK 430 450 04.016 LICION Electrically operated directional

More information

2/2- way directional valve type URZS40 Cover of directional valve type ULZS40

2/2- way directional valve type URZS40 Cover of directional valve type ULZS40 2/2- way directional valve type URZS40 Cover of directional valve type ULZS40 NS40 up to 42 MPa up to 1600 DT SHEET - SERVICE MNU NUL dm /min WK 421 750 0.201 PPLICTIN 2-way, 2-position directional valve

More information

Direct operated pressure relief valve type DBD

Direct operated pressure relief valve type DBD Direct operated pressure relief valve type DBD NS,, up to 3 Ma up to 50 DAA SHEE - OERAION MANUAL 3 dm /min WK 450.5 ALICAION A direct operated pressure relief valve type DBD is designed to limit maximum

More information

6-way section directional valves type 6URRE6

6-way section directional valves type 6URRE6 way section directional valve type URRE NS up to 5 Ma 80 dm /min D SHEE SERVICE MNU NUL WK 40 00 0.009 LICION way section directional valves type URRE are used to change direction of fluid flow in hydraulic

More information

6-way section directional valves type 6URRE6 consist

6-way section directional valves type 6URRE6 consist way section directional valve type URRE NS up to 5 Ma up to 80 D SHEE SERVICE MNU NUL dm /min WK 0 00 0.0 LICION way section directional valves type URRE are used to change direction of fluid flow in hydraulic

More information

Directional cartridge valve type. tight on both sides type 2URED6

Directional cartridge valve type. tight on both sides type 2URED6 Directional cartridge valve tight on both sides type URED6 NS 6 up to 31,5 MPa up to 5 DATA SHEET - SERVICE MANUA NUAL 3 dm /min WK 493 130 07.011 APPLICATION Directional cartridge valve type URED6 is

More information

Double throttle/check valve type Z2FS16

Double throttle/check valve type Z2FS16 Double throttle/check valve type Z2FS16 NS16 up to 5 MPa up to 250 D SHEE - OPERION MNUL dm /min WK 42 690 06.2015 PPLICION hrottle/check valve type Z2FS16 16... is used for setting the size of the main

More information

Pilot operated pressure relief valve type DB 3

Pilot operated pressure relief valve type DB 3 ilot operated pressure relief valve type DB NS, 0, 0 up to 5 Ma up to 650 dm /min DAA SHEE - SERVICE MANUA NUAL WK 0 07.011 ALICAION ressure relief valves type DB... serve to limit pressure in a hydraulic

More information

Directional cartridge valve tight on both sides type 2URED6 3

Directional cartridge valve tight on both sides type 2URED6 3 APPLICATION Directional cartridge valve type URED6 is intended for control direction of fluid flow, causing particular movement direction or stops a receiver (cylinder or hydraulic motor). The directional

More information

Directional spool valve type WH16 hydraulically operated

Directional spool valve type WH16 hydraulically operated Directional valve type WH16 hydraulically operated NS16 up to 5 MPa up to 240 dm /min WK 499 501 04.2009 PPLICION Directional valves type WH16 are intended for change in direction of fluid flow in a hydraulic

More information

Power pack type UHMZ 25

Power pack type UHMZ 25 ower pack type UHMZ 25 p max = 20 Ma Q = 10 max cm 3/rev WK 560 503 04.2008 LICION ower pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters (pressure

More information

2-WAY FLOW CONTROL VALVE TYPE UDRD6

2-WAY FLOW CONTROL VALVE TYPE UDRD6 -WY FLOW CONTROL VLVE TYPE UDRD6 WK 0 00 NS6 up to 31,5 MPa up to 3 dm 3 /min WK 0 00 -way flow control valve type UDRD6 serves to control fluid flow rate independently of pressure and temperature in direction

More information

Power pack type UHJV 250

Power pack type UHJV 250 Power pack type UHJV 250 p = 16 MPa max Q = 67 max 3 dm /min WK 560 501 04.2008 PPLICTION Power pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters

More information

Power pack type UHJV 63

Power pack type UHJV 63 Power pack type UHJV 63 p max = 10 MPa Q =13 max dm 3/min WK 560 498 04.2008 PPLICTION Power pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters

More information

Power pack type UHMZ 63

Power pack type UHMZ 63 Power pack type UHMZ 63 p max = 20 MPa Q = 10 3 cm /rev max WK 560 505 04.2008 PPLICTION Power pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters

More information

Power pack type UHPT

Power pack type UHPT Power pack type UHPT p = 32 MPa max Q = 25 max dm 3/min WK 560 658 04.2008 PPLICTION Power pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters (pressure

More information

Power pack type UHKZ

Power pack type UHKZ Power pack type UHKZ 3 p max = 20 MPa Q max= 9,8 cm /rev WK 576 898 05.2008 APPLICATION Power packs type UHKZ are designed to drive and control hydraulic receivers (cylinders and hydraulic motors). They

More information

Electrically operated directional spool valve with a soft-shift function type WE10P NS 10. up to 35 MPa up to 120 DATA SHEET - OPERATION MANUAL

Electrically operated directional spool valve with a soft-shift function type WE10P NS 10. up to 35 MPa up to 120 DATA SHEET - OPERATION MANUAL LICTION Electriclly operted directionl spool vlve with soft-shift function type WE10 NS 10 Electriclly operted directionl spool vlve type WE10 is intended for chnging the direction of fluid flow in hydrulic

More information

Double throttle/check valve type Z2FS10

Double throttle/check valve type Z2FS10 Duble thrttle/check valve type Z2FS0 NS0 up t,5 Ma up t dm /min WK 450 2 02.200 LICION hrttle/check valve type Z2FS0 0... is used t cntrl main flw rate (r pilt flw rate) in ne directin f flw and t allw

More information

Directional spool valve type WMM 16 hand lever operated

Directional spool valve type WMM 16 hand lever operated Directional spool valve type WMM 16 hand lever operated Size 16 35 MPa 180 dm 3 /min WK 450 209 04.2001r. Directional spool valves are used to control the direction of fluid flow and thus the direction

More information

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR Size, 20, 0 up to 1,5 MPa up to 00 dm /min. WK 495 690 04.1999r. Pilot operated pressure reducing valves type DR are used to reduce pressure in hydraulic

More information

6/2 way directional valve type 6/2UREM6 and 6/2URMM6

6/2 way directional valve type 6/2UREM6 and 6/2URMM6 6/2 wy directionl vlve type 6/2UREM6 nd 6/2URMM6 NS 6 dm 3 up to 35 MP up to 5 /min DT SHEET - SERVICE MNU NUL WK 421 54 11.212 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM6...

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16 size 16 up to 42 MPa 140 dm 3 /min WK 450 950 04.1999r. 2/2 way cartridge valve type URZS 16 can be used to build hydraulic systems

More information

Double throttle check valve Type Z2FS 10

Double throttle check valve Type Z2FS 10 RE 7 58/0.03 Replaces:.0 Double throttle check valve Type ZFS 0 Nominal size 0 Series 3X Maximum operating pressure 35 bar Maximum flow 0 L/min Overview of contents Contents Page Features Ordering details

More information

Proportional pressure reducing valve type 3WZCDE6 is a

Proportional pressure reducing valve type 3WZCDE6 is a LICION roportionl pressure reducing vlve type 3WZCDE6 3-wy electriclly controlled, proportionl pressure reducing vlve type 3WZCDE6 is used for reducing pressure in hydrulic system, in continuous wy, s

More information

Double throttle/check valve type Z2FS6

Double throttle/check valve type Z2FS6 Duble thrttle/check valve type ZF N up t,5 Ma up t 0 dm /min WK 4 00 0.0 LICION hrttle/check valve type ZF... is used t cntrl main flw rate (r pilt flw rate) in ne directin f flw and t allw free flw in

More information

Pressure reducing valve, pilot operated Type DR

Pressure reducing valve, pilot operated Type DR RE 6 9/0.0 Replaces: 0.0 Pressure reducing valve, pilot operated Type DR Nominal sizes 0 to Series Maximum operating pressure 0 bar Maximum flow 00 L/min K660-9 Type DR 0--/... Overview of contents Features

More information

Check valve, pilot operated

Check valve, pilot operated Check valve, pilot operated RE 21460/07.05 Replaces: 06.02 1/8 Types SV and SL Size 6 Component series 6X Maximum operating pressure 315 bar Maximum flow 60 l/min H6090 Table of contents Contents Page

More information

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW Size 10, 20, 30 31,5 MPa up to 600 dm 3 /min. WK 460 860 04.1999r. Pressure relief valves type DB... serve to limit pressure in a hydraulic system or in

More information

Flow sharing control block in mono block / sandwich plate design M6-15

Flow sharing control block in mono block / sandwich plate design M6-15 Flow sharing control block in mono block / sandwich plate design M6-15 RE 64321 Edition: 01.2015 Replaces: 05.2012 Size 15 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420

More information

Open center control block in mono block design MO-16, 22, 32

Open center control block in mono block design MO-16, 22, 32 Open center control block in mono block design MO-,, 3 RE 35 Edition: 0.0 Replaces: 0.003 Sizes,, 3 Series X Maximum working pressure on the pump side 350 bar on the consumer side 0 bar Maximum flow MO-:

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 685/.5 Replaces:. /6 Type DR K Size Component series X Maximum operating pressure 5 bar Maximum flow l/min K478/7 Table of contents Contents Page Features Ordering

More information

mobile hydraulics PONAR Wadowice S.A. is: the largest Polish producer of oil hydraulics elements and systems a supplier of a complete range of oil hydraulics the owner of a modern machinery park a trusted

More information

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve Types DBE(M) and DBE(M)E RE 29 142/11.02 Replaces: 02.99 Proportional pressure relief valve Types DE(M) and DE(M)E Nominal size 32 1) Series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H/ 1764 1) NS 10; 25, Series

More information

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y Pressure limitation and feed valve, pilot-operated Type MHDBN...Y RE 64600 Edition: 06.2018 Sizes 22, 32 Series 3X Maximum working pressure 420 bar Maximum flow 400 l/min H8121 Features Screw-in cartridge

More information

2-way flow control valve

2-way flow control valve -way flow control valve RE 8155/11.10 Replaces: 11.0 1/8 Type FRM Sizes 6 and 10 Component series 1X Maximum operating pressure 315 bar Maximum flow 60 l/min H501 Overview of contents Contents Page Features

More information

Steering unit LAGC. Data sheet

Steering unit LAGC. Data sheet Steering unit LAGC Data sheet Nominal sizes Series Maximum flow HE 14365 / 09.2017 40 1000 1 x and 2 x 80 l / min 2 LAGC HE 14365 / 09.2017 Page Content 4 4 5 6 7 8 9 10 11 12 13 14 Features Ordering details

More information

Electrically controlled directional control poppet valve type UREZ6

Electrically controlled directional control poppet valve type UREZ6 LICION Electriclly controlled directionl control poppet vlve type UREZ6 is intended for chnging the direction of hydrulic fluid flow in system, which llows for chnge of the direction of the receiver motion

More information

Check valve cartridge Type M-SR

Check valve cartridge Type M-SR RE /. Replaces:.9 Check valve cartridge Type M-SR Nominal sizes to Series X Maximum operating pressure bar Maximum flow L/min Overview of contents Contents Page Features Ordering details, symbols Preferred

More information

Flow sharing control block in mono block / sandwich plate design M6-22

Flow sharing control block in mono block / sandwich plate design M6-22 Flow sharing control block in mono block / sandwich plate design M6-22 RE 64322 Edition: 01.2015 Replaces: 05.2012 Size 22 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420

More information

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03 Pressure reducing valve, pilot operated Type DR RE 293 Edition: 2013-01 Replaces: 02.03 Sizes 10 and 2 Component series 1X; 4X Maximum operating pressure 31 bar Maximum flow 10 l/min H792 Features Contents

More information

Steering unit LAGZ. Data sheet. Series 2 x

Steering unit LAGZ. Data sheet. Series 2 x Steering unit LAGZ Data sheet Nominal sizes 125 620 Series 2 x Maximum flow 50 l / min HE 11868 / 09.2017 2 LAGZ HE 11868 / 09.2017 Page Content 4 4 5 6 7 8 9 10 11 12 13 14 Features Ordering details Function,

More information

Throttle and throttle check valve

Throttle and throttle check valve Throttle and throttle check valve RE 7/. Replaces:. / Types FG and FK Size to Component series X Maximum operating pressure bar Maximum flow 4 l/min H747 Table of contents Contents Page Features Ordering

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 6 SK (high-performance) RE 64655 Edition: 7.218 Replaces: 11.216 Size 6 Series 3X Maximum control pressure

More information

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min / Flow control valve. Type FRM,, Rectifier plate Type ZS,, Sizes, and Up to bar Up to L/min Contents Function and configuration Specification Technical data Characteristic curves Unit dimensions - Features

More information

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92 RE 1/09.9 1/03.9 Check-Q-meter type FD, series Sizes 1, 1,, 3 Up to 0 L/min Up to 30 bar RE 1/09.9 Replaces: 03.9 Features: For installation in manifolds (cartridge valve), With SE flanged ports, For sub-plate

More information

Flow sharing control block in sandwich plate design M7-25

Flow sharing control block in sandwich plate design M7-25 Flow sharing control block in sandwich plate design M7-25 RE 64297 Edition: 07.2016 Replaces: 06.2012 Size 25 Series 3X Maximum working pressure on the pump side 380 bar on the consumer side 420 bar Maximum

More information

Filling valve sandwich plate

Filling valve sandwich plate Filling valve sandwich plate RE 0478/08. Replaces: 06.06 /4 Type ZSF and ZSFW Size to 00 Component series ; Maximum operating pressure 50 bar Flow up to 7000 l/min ( p = 0. bar) Table of contents Contents

More information

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN 01 /10 2.2 HYDRULIC PILOT CONTROL UNIT OF SNDWICH PLTE DESIGN Type: H*-2TH6 Benefits: Progressive, sensitive control Precise and play-free control characteristics Low actuation force at the lever Rust-free

More information

Priority valve Type LPS

Priority valve Type LPS RE 27 548/10.98 riority valve Type LS Nominal sizes 40 to 160 Series 1X Nominal pressure 250 bar Maximum flow 160 L/min. H/AD/5977/98 riority valve type LS... Contents Description age Features 1 Ordering

More information

Trailer Brake Valves. Table of contents. Features. RE /05.11 Replaces: RE / Shut-down brake valve, BV1.

Trailer Brake Valves. Table of contents. Features. RE /05.11 Replaces: RE / Shut-down brake valve, BV1. Trailer rake Valves E 66 37/5. eplaces: E 66 37/.8 Shut-down brake valve, V ominal pressure: p nom = 25 bar Flow: Q max = l/min Table of contents Content age General 2 Determining the control piston Ø

More information

Check valve, pilot operated

Check valve, pilot operated Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Check valve, pilot operated Type ZS Size 6 Component series 6X Maximum operating pressure

More information

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve Types DBE(M) and DBE(M)E RE 29 142/02.99 Replaces: 06.97 Proportional pressure relief valve Types DE(M) and DE(M)E Nominal size 32 1) Series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H/ 1764 1) NS 10; 25, Series

More information

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07 Throttle check valve Type ZFS RE 758 Edition: 06-0 Replaces: 0.07 Size 0 Component series 3X Maximum operating pressure 35 bar [4569 psi] Maximum flow 60 l/min [4.3 US gpm] H5556 Features Sandwich plate

More information

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63 Table H004/E ISO cartridge valves type LIDD and LIQV Flow control, ISO 78 sizes LIDD LIQV/K LIDD and LIQV are flow control valves not compensated, in ISO cartridge design, made by a functional cover and

More information

Priority valve LPS. Data sheet. Series 1 x

Priority valve LPS. Data sheet. Series 1 x Priority valve LPS Data sheet Nominal sizes 40 160 Series 1 x Maximum flow 40 160 l / min HE 27548 / 10.2017 2 LPS HE 27548 / 10.2017 Page Content 4 4 5 6 7 8 9 10 11 12 13 14 Features Ordering details

More information

Throttle and throttle check valve

Throttle and throttle check valve Throttle and throttle check valve RE 79/0.09 Replaces: 0.06 /6 Types MG and MK Size 6 to 0 Component series X Maximum operating pressure 5 bar Maximum flow 400 l/min K564- Table of contents Contents Page

More information

Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series) Huade América 1

Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series) Huade América 1 Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series) Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series)

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

RC /

RC / 3 Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly Technologies Pneumatics Service utomation Mobile Hydraulics 09.96 DZ 10,, 3 31 bar 600 L/min K 663- DZ 0 --/31M 1 3 6 7 DIN

More information

Proportional flow control valve, with inductive position transducer

Proportional flow control valve, with inductive position transducer Proportional flow control valve, with inductive position transducer RE 29220/08.05 1/16 Type 3FREZ Nominal size 6, 10 Unit series 1X Maximum working pressure 250 bar Nominal flow rate Q nom 2.6...80 l/min

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) RE 64656 Edition: 07.18 Replaces: 11.16 Size 6 Series 3X Maximum control pressure

More information

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99 RE 29 564/03.99 Replaces: 29 563 Servo directional valve of 4-way design ype 4WS.2EM Nominal size 6 Series 2X Maximum operating pressures 210 / 315 bar Maximum flow 40 L/min H//D 5994/98 ype 4WS2EM 6-2X/.E...K17EV

More information

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, pilot operated Proportional pressure relief valve, pilot operated RE 29142/05.05 Replaces: 11.02 1/8 Types DE(M) and DE(M)E Size 32 1) Component series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H1764

More information

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting Vickers Counterbalance Valve C Series ainfold ounting 315 ar SE Flange ounting 80-560 L/min Subplate ounting Table of Contents Counterbalance Valve General Description...2 Functional Symbols...2 odel Code...3

More information

Pressure sequence valve, direct operated

Pressure sequence valve, direct operated ressure sequence valve, direct operated RE 26076/04.07 Replaces: 02.03 /6 Type DZ 6 D Nominal size 6 Series 5X aximum operating pressure 315 bar aximum flow 60 l/min K 4297-9 Overview of contents Contents

More information

Axial Piston Fixed Motor A2FM

Axial Piston Fixed Motor A2FM Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed

More information

Proportional Directional Valve System

Proportional Directional Valve System roportional Directional Valve System in Sectional Design Reference: 31--9589-ENG-2 Issue: 8.215 1/2 Contents age 1 General... 3 1.1 Description... 3 1.2 pplication examples... 3 2 Technical data... 3 3

More information

Pressure sequence valve pilot operated

Pressure sequence valve pilot operated /6 Pressure sequence valve pilot operated.4 Type DZ...L Sizes to Up to bar Up to 6 L/min Contents Function and configuration Symbols Specifications Technical data 4 Characteristic curves 4 Unit dimensions

More information

Pilot operated pressure relief valve

Pilot operated pressure relief valve 0/06 ilot operated pressure relief valve.6 ype ZD/ ZD 6V..L4X Size 6 up to 5bar up to 60 L/min Contents Function and configuration 0 Symbols 0 Specification 0 echnical data 0 Characteristic curves 0 Unit

More information

Electrohydraulic fan drive for fixed pump systems HICFD

Electrohydraulic fan drive for fixed pump systems HICFD Electrohydraulic fan drive for fixed pump systems HICFD RE 18305-05 Edition: 01.2018 Series 1X Maximum working pressure 250 bar Maximum flow 40 l/min Features Space-saving, efficient fan drive Infinitely

More information

Proportional pressure reducing valve

Proportional pressure reducing valve / Proportional pressure reducing valve. Type DRE(E)/ DREM(E)... Sizes, and Up to bar Up to L/min Contents Function and configuration Symbols Ordering code Technical data Electrical data Characteristic

More information

Steering unit LAGU. Data sheet

Steering unit LAGU. Data sheet Steering unit LAGU Data sheet Nominal sizes Nominal pressure Maximum flow HE 11867/09.2017 125 320 175 bar 50 l / min 2 LAGU HE 11867 / 09.2017 Page Content 4 4 5 6 7 8 9 10 11 12 13 14 Features Ordering

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Proportional pressure reducing valve, pilot operated RE 29178/4.5 Replaces: 11.2 1/1 Types DRE(M) and DRE(M)E Size 32 1) Component series 4X Maximum operating pressure 315 bar Maximum flow 3 L/min H2448

More information

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces: Pressure reducing valve, direct operated Type ZDR RE 657 Edition: 8-3 Replaces: 8- Size 6 Component series 4X Maximum operating pressure 35 bar Maximum flow 5 l/min H775 Features Sandwich plate valve Porting

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Pressure reducing valve, direct operated RE 6580/05.11 Replaces: 0.03 1/8 Type DR 10 DP Size 10 Component series 4X Maximum operating pressure 10 bar Maximum flow 80 l/min K4786/11 Table of contents Contents

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2018 Replaces: 03.2016 Technical data Description

More information

Pressure sequence valve, direct operated

Pressure sequence valve, direct operated Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com ressure sequence valve, direct operated Type DZ 6 D Nominal size 6 Series 5X aximum operating

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Proportional pressure reducing valve, pilot operated Type DRE and DREE Sizes 10 and 25 1) Component series 6X Maximum operating pressure Maximum flow Table of contents Content 315 bar 300 l/min Page Features

More information

3-way Proportional pressure reducing valve, pilot operated

3-way Proportional pressure reducing valve, pilot operated 01/12 3-way roportional pressure reducing valve, pilot operated 6.6 ype 3DRE(M) and 3DRE(M)E Component series L6X NG 10 and 16 Max pressure 315 bar Max flow: 125L/min(size 10) 300L/min(size 16) Contents

More information

Meter-in pressure compensator, direct operated

Meter-in pressure compensator, direct operated Meter-in pressure compensator, direct operated RE 94/.07 Replaces: 0.0 / ype ZDC Sizes 0 to Component series Maximum operating pressure bar Maximum flow l/min tb07 able of contents Content age Features

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

3/2 and 4/2 directional poppet valve with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 3/2 and 4/2 directional poppet valve with solenoid actuation ype M-.SED Size 10 Component

More information

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04 2-way flow control valve Type 2FRM, 2FRH, 2FRW RE 28389 Edition: 2013-05 Replaces: 07.04 Sizes 10 and 16 Component series 3X Maximum operating pressure 315 bar Maximum flow 160 l/min H5552 Features For

More information

Hydraulic Motor (Radial piston multi-stroke)

Hydraulic Motor (Radial piston multi-stroke) RE 15 207/03.94 Hydraulic Motor (Radial piston multi-stroke) Type MCR 10, Series 3X RE 15 207/02.98 Sizes 7 to1340 up to 450 bar up to 1340 cm 3 up to 27 Nm Replaces: 10.97 Compact, robust construction

More information

Proportional pressure reducing valve, in 3-way version

Proportional pressure reducing valve, in 3-way version roportional pressure reducing valve, in 3-way version RE 29184/06.11 Replaces: 12.02 1/12 ype 3DRE and 3DREE Size 6 Component series 2X Maximum operating pressure Maximum flow 100 bar 15 l/min able of

More information

Pressure relief valve, pilot operated

Pressure relief valve, pilot operated Pressure relief valve, pilot operated RE 64605/03.09 /8 Type MHDBV (high-performance) Sizes 6 and Component series 3X Maximum operating pressure 40 bar Maximum flow 40 l/min H7567 Table of contents Contents

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

2-way flow control valve

2-way flow control valve -way flow control valve RE 864/05. Replaces: 0.03 /8 ype ZFRM Size 6 Component series X Maximum operating pressure 35 bar Maximum flow 3 l/min H5379 able of contents Contents Page Features Ordering code

More information

Twin throttle check valve

Twin throttle check valve win throttle check valve RE 7506/05. Replaces: 0.03 /8 ype ZFS Size 6 Component series 4X Maximum operating pressure 35 bar Maximum flow 80 l/min H5556 able of contents Contents Page Features Ordering

More information

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS Throttle check valve RE 758/0.07 Replaces: 0.03 /8 Type ZFS Size 0 Component series 3X Maximum operating pressure 35 bar [4569 psi] Maximum flow 60 l/min [4.3 US gpm] H5556 Table of contents Content Page

More information

Vane pump, direct operated

Vane pump, direct operated Vane pump, direct operated RE 1/8.8 Replaces: 1. 1/18 Type PV7 A Nominal sizes 1 to Series 1X / X Maximum operating pressure 1 bar Displacement volume 1 to cm 3 H17 H9 Overview of contents Features Contents

More information

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, pilot operated Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service Proportional pressure relief valve, pilot operated R 29160/04.05 Replaces: 06.98 1/10 Model DE(M) and DE(M)E

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information