1 SPECIAL PURPOSE STEAM TURBINE SPECIFICATION SHEET ( ) CLIENT : BY REV MADE PROJECT TITL E : CHKD CHKD JOB NO. : APVD APVD DOC. NO. : ( 1 / 6 ) DATE DATE 1 APPLICABLE TO : PROPOSAL PURCHASE AS BUILT 2 FOR UNIT ITEM NO : 3 SITE MODEL NO. 4 SERVICE TYPE 5 MANUFACTURER NO. REQUIRED SERIAL NO. 6 7 NOTE : INDICATES INFORMATION TO BE COMPLETED BY PURCHASER MANUFACTURER 8 OPERATING CONDITIONS 9 INDICATE GUARANTEE POINT BY (*) STEAM RATE SITE DATA 10 POWER,kW SPEED, RPM KG/KW-HR ELEVATION m BAR : kg/cm 2 A 11 RATED TEMPERATURE O C SUMMER, 12 NORMAL RELATIVE HUMIDITY %, Design Wet Bulb : 13 UNUSUAL CONDITIONS 14 STEAM RATES BASED ON OUTPUT SHAFT OF : TUR GEAR DUST FUMES 15 EXHAUST RATED POINT KCAL/KG OTHER 16 RATED POINT 17 SPEEDS TURBINE TYPE CONSTRUCTION FEATURES O C WINTER 18 MAX CONTINUOUS RPM, TRIP RPM HORIZONTAL VERTICAL SINGLE VALVE MULTI VALVE 19 CRITICAL (DAMPED) 1'ST RPM, 2'ND RPM NO. OF STAGES IMPULSE REACTION 20 RIGID SUPPORT 1'ST RPM, 2'ND RPM OVERSPEED TRIP DEVICE MECH. ELECT. HYD. 21 STEAM CONDITIONS CASING SPLIT HORIZONTAL VERTICAL 22 INLET STEAM ROTOR SOLID BUILT-UP COMBINATION 23 RATED (NORMAL) kg/cm 2 A ROTATION, VIEWED FROM GOV. CW CCW 24 MAXIMUM kg/cm 2 A EXHAUST FLOW SINGLE DOUBLE 25 MINIMUM kg/cm 2 A GOVERNOR TYPE 26 EXHAUST STEAM ELECTRONIC HYDRAULIC OIL RELAY DIRECT ACT. 27 RATED (NORMAL) kg/cm 2 A NEMA CLASS 28 MAXIMUM kg/cm 2 A GOVERNOR MFR. MODEL 29 MINIMUM kg/cm 2 A SYNC. MOTOR kw OIL COOLER OIL HEATER 30 EXTRACTION POWER CYLINDER GOVERNOR PURGE REQUIRED 31 RATED (NORMAL) kg/cm 2 A STAINLESS STEEL PINS & BUSHING IN GOV. LINKAGE 32 MAXIMUM kg/cm 2 A ISOCRONOUS CONTROL SPEED DROP CONTROL 33 MINIMUM kg/cm 2 A SPEED CHANGER MANUAL PNEUM. ELECTR. 34 SPEED RANGE : kg/cm 2 G or ma 35 FLOW (kg/hr) NORMAL MAX. MIN kg/cm 2 G or ma 36 ADMISSION STEAM VALVES 37 RATED (NORMAL) kg/cm 2 A CAM LIFT BAR LIFT GRID VALVE 38 MAXIMUM kg/cm 2 A 39 MINIMUM kg/cm 2 A NO. AUTO GOV. VALVES NO. AUTO EXTR. VALVES 40 NO. AUTO ADM. VALVES 41 FLOW (kg/hr) NORMAL MAX. MIN SEPARATE TRIP & THROTTLE VALVE : HYD. MECH 42 REMOTE TRIP MANUAL ACTUATION 43 MAX THROTTLE FLOW : kg/hr SPRING SUPPORT REQ'D MANUAL EXCERSISER 44 MAX FLOW TONDENSER mm Hg V EXTRACTION NON-RETURN VALVE : HYD. MECH 45 MAX FLOW EXHAUST TEMP. IN OPERATION REMOTE TRIP MANUAL ACTUATION 46 MAX BHP MIN INLET/MAX EXH. kw ADMISSION STOP VALVE : HYD. MECH 47 DUTY REMOTE TRIP MANUAL ACTUATION 48 CONTINUOUS INTERMITTENT AUTO START Auto Valve Arranged Close On Trip : YES NO 49 APPROX. STEAM RATE DESIGN kg/kw.hr BLADES (BUCKETS) : 50 Tip Speed Max. Cont.: 1 st Stg Final Stg 51 LOCATION Final Stage Blade Length mm, Base Dia. mm 52 INDOOR HEATED UNDER ROOF Nozzle Ring : % Admission Welded Removable 53 OUTDOOR UNHEATED PARTIAL SIDE Blade Root : 1 st Stg Dove tail "T" Fir Tree 54 GRADE MEZZANIE Final Stg Dove tail "T" Fir Tree 55 WINTERIZATION TROPICALIZATION Shrouds : Welded Riveted Wire Damp

2 SPECIAL PURPOSE STEAM TURBINE DOC. NO. : ( 2 / 6 ) 1 CONSTRUCTION FEATURES ROTOR 2 BEARING HOUSING CONSTRUCTION BEARING SPAN mm 3 TYPE (SEPARATE, INTEGRAL) SPLIT SHAFT DIA. 1st END GLAND SEAL 4 MATERIAL 5 RADIAL BEARINGS MAIN CONNECTIONS 6 TYPE L/D DIA.(mm) ANSI 7 AREA (cm 2 ) LOADING (kg/cm 2 ), ACT. ALLOW. SIZE RATING FACING POSITION 8 THRUST BEARING INLET 9 LOCATION TYPE EXHAUST 10 MFR. AREA (cm 2 ) EXTRACTION 11 LOADING (kg/cm 2 ), ACT. ALLOW. ADMISSION PACKING TYPE ALLOWABLE FORCES AND MOMENTS 14 INTERSTAGE GLAND SEALS INLET EXHAUST EXTR./ADM 15 END GLAND SEALS NO. PER BOX Force, Moment Force, Moment Force,Mom't 16 P PER SEAL kg/cm 2 MATERIAL kg kg-m kg kg-m kg kg-m 17 INSULATION JACKET MAT'L PARALLEL 18 TOTAL EXPECTED LEAKAGE kg/hr TO SHAFT 19 LABYRINTH TYPE STATIONARY ROTATING VERTICAL 20 HORIZ. 90 O 21 GLAND SEALING SYSTEM 22 GLAND CONDENSER W/MOUNTING FEET REQ'D OTHER CONNECTIONS 23 STEAM EJECTOR REQ'D kg/cm 2 G NO. SIZE ANSI FACING 24 VACUUM DEVICE REQ'D COMPOUND PRES. GAGE REQ'D RATING 25 AUTO. PRESSURE CONTROL VALVE (Motive Steam / Sealing Steam) LUBE OIL INLET 26 GLAND COND. DRAIN: Loop Seal Vertical Leg LUBE OIL OUTLET 27 Other GLAND COND'R CONN. 28 MINIMUM COND. DRAIN HEIGHT mm STAGING DRAIN 29 RELIEF VALVE ON SEALING STEAM HEADER STEAM RING DRAIN 30 T & T VALVE H.P. STEAM 31 CAPABILITIES LEAKOFF 32 MAX STEAM THRU INLET VALVE kg/hr 1) T & T VALVE L.P. STEAM 33 MAX STEAM THRU EXHAUST VALVE kg/hr 1) LEAKOFF 34 STEAM INLET PARTS T & T VALVE ABOVE 35 MAX ALLOW. PRESS. kg/cm 2 G SEAT DRAIN 36 EXHAUST END CASING T & T VALVE BELLOW 37 MAX ALLOW. PRESS. kg/cm 2 A or mmhg V SEAT DRAIN 38 MAX ALLOW. TEMP. 39 MAX EXPECTED TEMP. DURING NO LOAD RUN IN 40 SENTINEL WARNING VALVE kg/cm 2 G HOUSING COOLING WATER CONN. PURGE FOR BEARING 41 HYDROSTATIC TEST PRESSURE EXHAUST CONN. 42 STEAM INLET PARTS kg/cm 2 G 43 EXHAUST END kg/cm 2 G 44 FUTURE POTENTIAL MAX. HORSE POWER kw BASE PLATES & SOLE PLATES 45 WITH MINOR MODIFICATION : BASE PLATE BY 46 DECKED WITH NON SKID DECK PLATE OPEN CONSTRUCTION 47 TURBINE MATERIALS DRIP RIM WITH OPEN DRAIN 48 HIGH PRESSURE CASING UNDER TURBINE ONLY OTHER 49 EXHAUST CASING MID CASING SOLE PLATE BY 50 NOZZLES BLADES HORIZ. ADJUSTING SCREWS FOR EQUIPMENT 51 WHEELS SHAFT FURNISH S.S. SHIMS 52 STEAM CHEST FOUNDATION BOLTS FURN BY : VENDOR PURCH. 53 DIAPHRAGMS LEVELING (CHOCK) BLOCKS REQ'D 54 NOZZLE RINGS 55 SHROUDS REFERENCE SPECIFICATIONS : 56 GOV. VALVE TRIM API 612 SPECIAL PURPOSE STEAM TURBINE LABYRINTH SEALS 58 SHAFT MATERIAL UNDER SEALS 59 Applied by Spraying Plating Sleeve 60

3 SPECIAL PURPOSE STEAM TURBINE DOC. NO. : ( 3 / 6 ) 1 UTILITIES 2 COOLING WATER 3 NORMAL MAX. DESIGN MAX. TEMP. RISE ALLOWED 4 SUPPLY PRESS., kg/cm 2 G QUANTITY REQUIRED 5 SUPPLY TEMP., m 3 /hr L/D FOR 6 PRESSURE DROP, kg/cm 2 m 3 /hr L/D FOR 7 AUXILIARY STEAM SUPPLY 8 NORMAL MAX. DESIGN QUANTITY REQUIRED 9 SUPPLY PRESS., kg/cm 2 G kg/hr L/D FOR 10 SUPPLY TEMP., kg/hr L/D FOR 11 INSTRUMENT AIR SUPPLY AUXILIARY MOTORS 12 SUPPLY PRESS., kg/cm 2 G Volts Phase Hz INSTRUMENTATION 15 GAUGE READOUT IN ENGLISH SI DUAL OTHER 16 NOTE : SUPPLIED BY VENDOR SUPPLIED BY PURCHASER LOCATED ON A MACHINE MOUNTED INSTRUMENT BOARD PRESSURE GAGE REQUIREMENTS 19 LOCALLY LOCAL LOCALLY LOCAL 20 FUNCTION MOUNTED PANEL FUNCTION MOUNTED PANEL 21 LUBE OIL PUMP DISCHARGE 1st STAGE STEAM 22 LUBE OIL FILTER P STEAM CHEST 23 LUBE OIL SUPPLY EXHAUST STEAM 24 GOV. CONTROL OIL EXTRACTION STEAM 25 GOV. CONTROL OIL P STEAM EJECTOR 26 COUPLING OIL P STEAM SEAL 27 MAIN STEAM INLET TEMPERATURE GAGE REQUIREMENTS LOCALLY LOCAL LOCALLY LOCAL 32 FUNCTION MOUNTED PANEL FUNCTION MOUNTED PANEL 33 LUBE OIL DISCHARGE FROM EACH COOLING OIL INLET & OUTLET 34 TURBINE JOURNAL BEARING STEAM INLET 35 TURBINE THRUST BEARING STEAM EXHAUST 36 GEAR JOURNAL BEARING ALARMS & SHUTDOWN FUNCTIONS 39 PRE PRE 40 FUNCTION ALARM TRIP FUNCTION ALARM TRIP 41 LOW LUBE OIL PRESS. EACH LEVEL TURBINE VIBRATION 42 HI OIL FILTER TURBINE AXIAL POSITION 43 AUX. LUBE OIL PUMP START TRIP & THROTTLE VALVE POSITION 44 HI LUBE OIL OUTLET TEMP. HI TURBINE STEAM SEAL LEAKAGE 45 LOW CONTROL OIL PRESSURE HI TURBINE EXHAUST PRESSURE 46 HI TURBINE EXTRACTED PRESSURE 47 TURB. OVERSPEED TRIP OPERATION MISCELLANEOUS INSTRUMENTATIONS 50 TURBINE SPEED PICK UP DEVICE ELECTRONIC OTHER ; 51 TURBINE SPEED INDICATORS 52 TURBINE SPEED INDICATORS LOCATED ON : LOCAL PANEL MAIN BOARD TYPE : DIGITAL DIAL GAGE 53 REMOTE HAND SPEED CHANGER-MOUNTED ON : LOCAL PANEL CONTROL ROOM 54 ALARM HORN & ACKNOWLEDGEMENT SWITCH ON : LOCAL PANEL CONTROL ROOM

4 SPECIAL PURPOSE STEAM TURBINE DOC. NO. : ( 4 / 6 ) 1 COUPLING VIBRATION DETECTORS 2 MOUNT 1/2 COUPLING TYPE TYPE MODEL 3 MFR. MFR. 4 SPACER REQ'D NO. AT EACH SHAFT BEARING TOTAL NO. 5 COUPLING FURNISHED BY OSCILATOR-DEMODULATORS SUPPLIED BY: 6 KEYED (1) OR (2); OR HYDR. FIT MFR. MODEL 7 CPLG. COEF. FRICTION: GEAR PITCH DIA.(mm): MONITOR SUPPLIED BY NO. CHANNEL 8 TURBINE SHAFT : TAPER CYLIND'L DIA.(mm): LOCATION ENCLOSURE 9 GENERATOR SHAFT: TAPER CYLIND'L DIA.(mm): MFR. MODEL 10 COUPLING GUARD : MFR. STD. OTHER SCALE RANGE ALARM : M 11 LUBRICATION REQ'D YES NO SHUTDOWN : M TIME DELAY sec COMPOSITE TORSIONAL ANALYSIS AXIAL MOVEMENT DETECTORS 14 REQUIRED BY : TYPE MODEL 15 LATERAL CRITICAL SPEED ANALYSIS MFR. NO. REQUIRED 16 REQUIRED BY : OSCILATOR-DEMODULATORS SUPPLIED BY: 17 MFR. MODEL 18 SHOP INSPECTION AND TESTS MONITOR SUPPLIED BY NO. CHANNEL 19 REQ'D WITNESS LOCATION ENCLOSURE 20 SHOP INSPECTION MFR. MODEL 21 HYDROSTATIC(PIPING,CASING,CONDENSER) SCALE RANGE ALARM : M 22 BLADE SHAKER (STATIC) ROWS SHUTDOWN : M TIME DELAY sec. 23 ROTOR BALANCE: VACUUM PIT STD. 24 ROTOR THERMAL STABILITY KEYPHASER SENSOR 25 MECHANICAL RUN : W/JOB CPLG. 1/2 TYPE MODEL 26 RUN SPARE ROTOR W/JOB CPLG. 1/2 MFR. NO. REQUIRED 27 LOCATION ENCLOSURE 28 FUNCTIONAL TEST : T & T VALVE OSCILATOR-DEMODULATOR SUPPLIED BY 29 TURNING GEAR MFR. MODEL 30 GLAND CONDENSER MONITOR SUPPLIED BY NO. CHANNEL 31 SEALING DEVICE LOCATION ENCLOSURE 32 LUBE OIL SYSTEM MFR. MODEL 33 GOVERNOR STABILITY 34 TURBINE RUN AT OVERSPEED AND TRIP 35 USE SHOP LUBE SYSTEM BEARING TEMPERATURE DEVICES 36 USE JOB LUBE SYSTEM THERMISTORS : 37 USE JOB VIBRATION & DISPL. PROBES ETC. TYPE: Positive Temp. Coef. Neg. Temp. Coef. 38 OSCILATOR-DEMODULATORS & MONITOR Temp. Switch & Indicator By : Purchaser Mfr. 39 USE SHOP VIBRATION PROBES ETC. THERMOCOUPLES : 40 X-Y-Y" PLOT Selector Switch & Indicator By: Purchaser Mfr. 41 CHECK BEARING & SEALS AFTER TEST RESISTANCE TEMP. DETECTORS : 42 NOISE LEVEL TEST Resistance Material : OHM 43 PREPARATION FOR SHIPMENT Selector Switch & Indicator By : Purchaser Mfr. 44 FM TAPE RECORDING (VIBRATION) LOCATION OF JOURNAL BEARING : 45 CLEANLINESS INSPECTION (API 612) No. Ea. Pad Every Other Pad Per Bearing 46 HARDNESS TEST (API 612) Other 47 LOCATION OF THRUST BEARING : 48 OIL REQUIREMENTS No.(Active) : Ea. Pad Every Other Pad Per Bearing 49 CONTROL OIL LUBE OIL Other 50 MAX. QUANTITY (lt/min) No.(Inactive): Ea. Pad Every Other Pad Per Bearing 51 PRESSURE, kg/cm 2 G Other 52 TEMPERATURE MAXIMUM BEARING TEMPERATURE : 53 TOTAL HEAT REJECTED, kcal/hr FOR ALARM FOR SHUTDOWN 54 OIL REQUIRED FOR T & T VALVE HYD. NON-RETURN 55 VALVE & (ADMISSION STOP VALVE) REMARK : 56 OIL VISCOSITY 32

5

6 SPECIAL PURPOSE STEAM TURBINE DOC. NO. : ( 5 / 6 ) 1 INSTRUMENTATION 2 EXHAUST RELIEF VALVE REQUIREMENTS AREA CLASSIFICATION 3 MAX SET PRESSURE kg/cm 2 G EXHAUST CLASS GROUP DIVISION 4 STEAM ROW kg/hr MOTOR CONTROL & INSTRUMENT VOLTAGE 5 SUPPLIED BY PURCHASER VENDOR VOLTS PHASE Hz 6 EXTRACTION RELIEF VALVE REQUIREMENTS ALARM & SHUTDOWN VOLTAGE 2 7 MAX SET PRESSURE kg/cm G EXTRAXTION VOLTS PHASE Hz 8 STEAM ROW kg/hr SOLENOID VOLTAGE VOLTS 9 SUPPLIED BY PURCHASER VENDOR LOCAL CONTROL PANEL 12 FURNISHED BY VENDOR PURCHASER OTHER 13 FREE STANDING WEATHER PROOF TOTALLY ENCLOSED EXTRA CUTOUTS 14 VIBRATION ASCILATOR STRIP HEATER PURGE CONNECTION WITH DOORS 15 ANNUNCIATOR FURNISHED BY VENDOR PURCHASER OTHERS 16 ANNUNCIATOR LOCATED ON : LOCAL PANEL CONTROL ROOM MAIN CONTROL BOARD 17 CUSTOMER CONNECTIONS BROUGHT OUT TO TERMINAL BOXES BY VENDOR 18 REMARKS : INSTRUMENT SUPPLIERS : FOLLOWING LIST REFER TO "DATASHEET FOR INSTRUMENT DOC./DWG. NO. 22 Pressure Gages MFR. : SIZE & TYPE : 23 Temperature Gages MFR. : SIZE & TYPE : 24 Level Gages MFR. : SIZE & TYPE : 25 Diff. Pressure Switches MFR. : SIZE & TYPE : 26 Temperature Switches MFR. : SIZE & TYPE : 27 Level Switches MFR. : SIZE & TYPE : 28 Control Valves MFR. : SIZE & TYPE : 29 Pressure Relief Valves MFR. : SIZE & TYPE : 30 Thermal Relief Valves MFR. : SIZE & TYPE : 31 Sight Flow Indicators MFR. : SIZE & TYPE : 32 Pneu. Pressure Transmitters MFR. : SIZE & TYPE : 33 Vibration Equipment MFR. : SIZE & TYPE : 34 Tachometer MFR. : SIZE & TYPE : 35 Solenoid Valves MFR. : SIZE & TYPE : 36 Annunciator MFR. : SIZE & TYPE : 37 Thermocouples MFR. : SIZE & TYPE : 38 Resistance Temp. Detectors MFR. : SIZE & TYPE : 39 Thermowells MFR. : SIZE & TYPE : 40 MFR. : SIZE & TYPE : 41 MFR. : SIZE & TYPE : 42 MFR. : SIZE & TYPE : 43 MFR. : SIZE & TYPE : 44 MFR. : SIZE & TYPE : SWITCHES 47 ENCLOSURES EXPLOSION PROOF WEATHER PROOF OTHER 48 ALARM CONTACTS SHALL OPEN CLOSE TO SOUND ALARM - AND BE NORMALLY ENERGIZED DE-ENERGIZED 49 SHUTDOWN CONTACT SHALL OPEN CLOSE TO TRIP - END BE NORMALLY ENERGIZED DE-ENERGIZED 50 NOTE : NORMAL CONDITION IS : WHEN TURBINE IS IN OPERATION 51 MISCELLANEOUS 52 PRE-ALARM AND SHUTDOWN SWITCHES SHALL BE SEPARATE 53 PURCHASERS ELECTRICAL AND INSTRUMENT CONNECTIONS WITHIN THE CONFINES OF THE BASEPLATE AND CONSOLE SHALL BE : 54 BROUGHT OUT TO TERMINAL BOXES MADE DIRECTLY BY PURCHASER 55 PURCHASER'S COMMENTS : 56 58

7 SPECIAL PURPOSE STEAM TURBINE DOC. NO. : ( 6 / 6 ) 1 GEAR WEIGHT 2 SEPARATE DATASHEET ATTACHED TURBINE kg 3 SPECIAL PURPOSE GEAR REQUIRED ROTOR kg 4 GEAR FURNISHED BY : TURBINE UPPER 1/2 CASING kg 5 OIL SYSTEM MAX. FOR MAINTENANCE (IDENTIFY) kg 6 FURNISHED BY : TURBINE MFR. OTHERS ( ) 7 SEPARATE FOR TURBINE ONLY TOTAL SHIPPING WEIGHT kg 8 COMMON WITH DRIVEN EQUIPMENT 9 TURBINE MFR. TO SUPPLY SPACE REQUIREMENTS 10 STAINLESS STEEL OIL SUPPLY HEADER PIPING COMPLETE UNIT : L (m) W (m) H (m) 11 OIL DRAIN HEADER PIPING ST. STEEL C.S. CONTROL PANEL : L (m) W (m) H (m) EMERGENCY TURNING-GEAR MISCELLANEOUS 15 TURNING GEAR REQ'D QUICK START REQUIRED PROVISIONS FOR FIELD BALANCING 16 MFR. MODEL VENDOR'S REVIEW AND COMMENT ON PURCHASER'S PIPING 17 RATIO AND FOUNDATION DRAWINGS REQUIRED 18 MOTOR Electric kw VOLTS AC DC SHAFT GROUNDING DEVICES 19 Pneumatic kg/cm 2 G Nm 3 /hr "Y" TYPE STRAINER FOR 20 Auto Engage Manual Engage WATER WASHING CONNECTIONS 21 OPTICAL ALIGNMENT FLATS 22 PAINTING INSULATION (LAGGING) REQUIRED 23 MANUFACTURER'S STANDARD JACKET REQUIRED 24 OTHER AXIAL ALIGNMENT KEY 25 BLADE DIAGRAMS CAMPBELL GOODMAN 26 SHIPMENT SODERBERG OTHER 27 DOMESTIC EXPORT METRIC / ENGLISH / SI 28 EXPORT BOXING REQ'D OUTDOOR STORAGE OVER 6 DRAWINGS EXTERNAL FLANGES 29 WATER PROOF BOXING REQ'D (SIX) MONTHS INTERNAL BOLTING AND THREADS 30 SPARE ROTOR ASSEMBLY PACKAGED FOR 31 HORIZONTAL STORAGE VERTICAL STORAGE 32 SKETCH : REMARKS :

APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS

APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS 29 JOB NO. GENERAL-PURPOSE STEAM TURBINE PURCHASE ORDER NO. DATA SHEET SPECIFICATION NO. SI UNITS REVISION NO. DATE PAGE 1 OF 3 BY ITEM NO. 1 APPLICABLE

More information

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering Guardian Packing Rings Vortex Shedder Seals Turbine Components Custom Installation Reverse Engineering ADVANCED SEALING SYSTEM by Turbo Parts, LLC. Guardian Packing Rings Prevent Seal Damage While Maintaining

More information

PWD. PWD API 610 BB1 Single Stage Pump

PWD. PWD API 610 BB1 Single Stage Pump PWD PWD API 610 BB1 Single Stage Pump HYDRAULIC PERFORMANCE COVERAGE FLOW (m 3 /h) 50 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain

More information

MATERIAL AND EQUIPMENT STANDARD FOR SPECIAL PURPOSE STEAM TURBINES

MATERIAL AND EQUIPMENT STANDARD FOR SPECIAL PURPOSE STEAM TURBINES MATERIAL AND EQUIPMENT STANDARD FOR SPECIAL PURPOSE STEAM TURBINES CONTENTS : PAGE No. 0. INTRODUCTION... 3 1. GENERAL... 4 1.1 Scope... 4 1.2 Alternative Designs... 4 1.3 Conflicting Requirements... 4

More information

PWM API 610 BB3 Multistage Pump

PWM API 610 BB3 Multistage Pump PWM API 610 BB Multistage Pump PWM API 610 BB MULTISTAGE PUMP HYDRAULIC PERFORMANCE COVERAGE 60 Hz Performance Coverage FLOW (m /h) Visit our web site at www.pumpworks610.com and specify flow and performance

More information

Annexure - C SL NO DESCRIPTION W SB TOTAL KW 1 WWS-Lime dosing tank-agitator WWS-Poly electrolyte dosing pumps WWS-Lime dosing pumps

Annexure - C SL NO DESCRIPTION W SB TOTAL KW 1 WWS-Lime dosing tank-agitator WWS-Poly electrolyte dosing pumps WWS-Lime dosing pumps Annexure - C SL NO DESCRIPTION W SB TOTAL KW 1 WWS-Lime dosing tank-agitator 1 0 1 2 WWS-Poly electrolyte dosing pumps 1 1 2 3 WWS-Lime dosing pumps 1 1 2 4 WWS-PAC dosing pumps 1 1 2 5 WWS-DWPE dosing

More information

Date of Issue: Affected Publication: ERRATA Cover, Part 1, Annex A,

Date of Issue: Affected Publication: ERRATA Cover, Part 1, Annex A, Date of Issue: May 2008 Affected Publication: API Standard 614, Lubrication, Shaft-sealing and Oil-control Systems and Auxiliaries, Fifth Edition, April 2008 ERRATA Cover, Change: (Modified) to (Identical)

More information

MATERIAL AND EQUIPMENT STANDARD FOR GENERAL PURPOSE CENTRIFUGAL FANS ORIGINAL EDITION DEC. 1994

MATERIAL AND EQUIPMENT STANDARD FOR GENERAL PURPOSE CENTRIFUGAL FANS ORIGINAL EDITION DEC. 1994 MATERIAL AND EQUIPMENT STANDARD FOR GENERAL PURPOSE CENTRIFUGAL FANS ORIGINAL EDITION DEC. 1994 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither

More information

SECTION H3 TRAYMASTER SERIES DEAERATORS

SECTION H3 TRAYMASTER SERIES DEAERATORS SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...

More information

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency PRODUCTS Multi-Stage Steam Turbines Proven reliability and efficiency Introduction Proven Reliability and Efficiency Dependable, versatile turbomachinery is essential for today s refinery, chemical process,

More information

HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3

HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3 Page 1 of 7 HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3 STANDARD SPECIFICATION FOR OIL MIST LUBRICATION SYSTEM DOCUMENT NO : 44LK-5100-704/M.02/0024/A4

More information

GUJARAT NARMADA VALLEY FERTILIZERS COMPANY LIMITED MTPA PAC PROJECT SECTION 6 ANNEXURE 4.7 SPARES, INSP AGENCY & DOCUMENTATION

GUJARAT NARMADA VALLEY FERTILIZERS COMPANY LIMITED MTPA PAC PROJECT SECTION 6 ANNEXURE 4.7 SPARES, INSP AGENCY & DOCUMENTATION A. SPARE PARTS Outline for the supply of Spare Parts for various items is as elaborated below: A-1 MACHINERY Commissioning spares will be as per the manufacturer s recommendations. For 2 years of normal

More information

GLN ID-CIN-HD DE 5

GLN ID-CIN-HD DE 5 INGENIERIA DE DETALLE MEJORAMIENTO DE LOS SISTEMAS CONTRA INCENDIO DE LAS ESTACIONES: MARIQUITA, HERVEO, MANIZALES, PEREIRA, CARTAGO, DAGUA,BUENAVENTURA,NEIVA,GUALANDAY Y CISNEROS 02-D-10-MEC-DS-00 0/06/201

More information

PWM APi 610 BB3 Multistage Pump

PWM APi 610 BB3 Multistage Pump PWM APi 610 BB3 Multistage Pump HyDrAUliC PerfOrMAnCe COVerAge FLOW (m 3 /h) 60 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain pump

More information

Document Code: 1 (8) Issuing date: Status:

Document Code: 1 (8) Issuing date: Status: Document Code: 1 (8) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Employer: JJA Document title: SYSTEM DESCRIPTION TURBINE CONTROL Submitted for: Employer reference: Other information: Document

More information

STANDARD DATA SHEET FOR. Integrally Gear Centrifugal Compressor

STANDARD DATA SHEET FOR. Integrally Gear Centrifugal Compressor TOYO ENGINEERING INDIA LIMITED. STANDARD DATA SHEET FOR Integrally Gear Centrifugal Compressor ISSUE R0 REQ. NO. Standard Data Sheet No. API - 672 Project Document No. -A-95-46-001 4807 JOB DATE 8/5/2009

More information

Steam Turbines and Gas Expanders. Reliability, Efficiency, Performance

Steam Turbines and Gas Expanders. Reliability, Efficiency, Performance Steam Turbines and Gas Expanders Reliability, Efficiency, Performance Introduction Proven Reliability and Efficiency Dependable, versatile turbomachinery is essential for today s refinery, chemical process,

More information

PWM. API 610 BB3 Multistage Pump

PWM. API 610 BB3 Multistage Pump PWM API 610 BB3 Multistage Pump HYDRAULIC PERFORMANCE COVERAGE FLOW (m 3 /h) 60 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain pump

More information

YR Steam Turbines PRODUCT

YR Steam Turbines PRODUCT YR Steam Turbines PRODUCT Elliott YR Steam Turbines Elliott YR steam turbines are rugged and reliable pieces of precision turbomachinery. These masterpieces of Elliott engineering and craftsmanship serve

More information

The Consortium of SKEC and GS E&C

The Consortium of SKEC and GS E&C n are the property of SK Engineering & Const. Co. Ltd (SKEC). They are merely loaned and shall not be disclosed to others or reproduced in any manner without written permission of SKEC. PROJECT NO. PROJECT

More information

6. Document tasks performed during visit and report any observations to the appropriate

6. Document tasks performed during visit and report any observations to the appropriate Chiller Annual Maintenance RFP Attachment B Services Required Tasking: Vibration Analysis 1. All work shall be performed in accordance with safety policies 2. Check with appropriate customer representative

More information

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency. CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage

More information

Instruction Manual for Single Stage 350, 500, and 700 Frame Steam Turbines

Instruction Manual for Single Stage 350, 500, and 700 Frame Steam Turbines Instruction Manual for Single Stage 350, 500, and 700 Frame Steam Turbines Manual 107-A How to Use This Manual Dresser-Rand SST 350, SST 500, and SST 700 Single Stage Turbine Instruction Manual March 2011

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

VM / VML COMPONENT PARTS CATALOGUE

VM / VML COMPONENT PARTS CATALOGUE VM / VML REFRIGERATION COMPRESSOR COMPONENT PARTS CATALOGUE Ver. 2002 HASEGAWA CONTENTS Model VM / VML Compressor Description Parts # Crankcase Component Parts External Casing Fittings Covers & Gaskets

More information

PIP RESP73H Application of ASME B Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

PIP RESP73H Application of ASME B Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process May 2013 Process Industry Practices Machinery PIP RESP73H Application of ASME B73.1-2001 Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process PURPOSE AND USE OF PROCESS INDUSTRY

More information

SECTION H4 BOILERMATE DEAERATORS

SECTION H4 BOILERMATE DEAERATORS SAMPLE SPECIFICATIONS PART 1 SECTION H4 BOILERMATE DEAERATORS GENERAL...H4-14 1.01 General...H4-14 PART 2 PRODUCTS...H4-14 2.01 Hardware...H4-14 A. Deaerator...H4-14 B. Make Up Valve and Controller...H4-15

More information

Table of Contents. Equipment Summary...3. Performance and Value Vs. New Equipment...3. Reliability.. 3

Table of Contents. Equipment Summary...3. Performance and Value Vs. New Equipment...3. Reliability.. 3 Table of Contents Section Page Equipment Summary.....3 Performance and Value Vs. New Equipment.....3 Reliability.. 3 Steam Turbine Design Details and Capabilities....5 Steam Turbine Application and Reapplication

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Fundamentals of steam turbine systems

Fundamentals of steam turbine systems Principles of operation Fundamentals of steam turbine systems - The motive power in a steam turbine is obtained by the rate of change in momentum of a high velocity jet of steam impinging on a curved blade

More information

Centac C3000. Basic Frame Description. Process Air Solutions ESA. Date : 05/2011 Revision : 2. The picture may not represent the version offered.

Centac C3000. Basic Frame Description. Process Air Solutions ESA. Date : 05/2011 Revision : 2. The picture may not represent the version offered. Page : 1 of 13 The picture may not represent the version offered. Basic Frame Description Page : 2 of 13 Basic Frame Description 1 Introduction The CENTAC C3000 compressor is a reliable and efficient integrally

More information

MARIM Steam Turbines. Engineering the Future - since MAN Diesel & Turbo

MARIM Steam Turbines. Engineering the Future - since MAN Diesel & Turbo MARIM Steam Turbines Engineering the Future - since 1758. MAN Diesel & Turbo Introduction MAN has over a century of experience in manufacturing steam turbines for industrial applications and utilities

More information

Tilting Pad Journal Bearings

Tilting Pad Journal Bearings Tilting Pad Journal Bearings Types W140 and W141 Diameter Range 40 355 mm Standard GTW Tilting Pad Journal Bearings type W140 with 4-pads and W141 with 5-pads. These bearings are used in high speed machines,

More information

SAMPLE SPECIFICATIONS

SAMPLE SPECIFICATIONS SAMPLE SPECIFICATIONS CONTENTS PART 1 GENERAL...H1a-12 1.1 DEAERATOR SPECIFICATION...H1a-12 PART 2 PRODUCTS...H1a-12 2.1 HARDWARE...H1a-12 A. Deaerator...H1a-12 B. Make Up Valve and Controller...H1a-14

More information

Electric Actuators Maximum in-lbs

Electric Actuators Maximum in-lbs Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except

More information

STANDBY 2860 ekw 3575 kva 50 Hz 1000 rpm

STANDBY 2860 ekw 3575 kva 50 Hz 1000 rpm DIESEL GENERATOR SET STANDBY 2860 ekw 3575 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility,

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

Electric Actuators Maximum in-lbs

Electric Actuators Maximum in-lbs Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

CONTINUOUS 3520 ekw 4400 kva 50 Hz 1000 rpm

CONTINUOUS 3520 ekw 4400 kva 50 Hz 1000 rpm DIESEL GENERATOR SET CONTINUOUS 3520 ekw 4400 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched

More information

PRIME 3880 ekw 4850 kva 50 Hz 1000 rpm

PRIME 3880 ekw 4850 kva 50 Hz 1000 rpm DIESEL GENERATOR SET PRIME 3880 ekw 4850 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility,

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

900 Series Split Case Fire Pump Systems

900 Series Split Case Fire Pump Systems BULLETIN 900/REV. E 900 Series Split Case Fire Pump Systems MODEL 481 MODEL 483 FM Approved U L Listed motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48

More information

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T S STANDBY PRIME 60 Hz 60-100 kw 54-90 kw Model Standby Prime kw (kva) kw (kva) D60P4S* 60 (60) 54 (54) D75P3 75 (93.8) 68 (85) D80P4* 80 (100) 72 (90) D75P1S 75 (75)

More information

Disc Valve Hydraulic Motors Series 4000

Disc Valve Hydraulic Motors Series 4000 Disc Valve Hydraulic Motors Series 0 10.20 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.20 EN EATON_Motoren english Highlights Features 10 displacements, a variety of mounting flanges

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Acceptance Inspection Date of Review / / BLD20 - Project Address: Project Name: Numbers following worksheet comments represent an NFPA

More information

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

Contents. Identification

Contents. Identification Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions

More information

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates Issued 2005/06/01 Section 16239 Power Generation to 30 kw Page 1 of 7 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01355 Waste Management and Disposal..2 Section 01810 Commissioning..3 Section 03100 Concrete

More information

Engineers Without Borders

Engineers Without Borders Engineers Without Borders Proposal No: JI12-02-07 04 Item No: ITEM 001 February 7, 2012 Attn: Adam MODEL:VIT-CATM Size:7CHC 10 Stage(s) QTY:1 Operating conditions SERVICE LIQUID LIQUID TYPE CAPACITY RATED

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

Improve Steam Turbine Efficiency

Improve Steam Turbine Efficiency Improve Steam Turbine Efficiency Understand the factors that affect steam consumption Steam are a major energy consumer. Optimising process operating conditions can considerably improve turbine water rate,

More information

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls. Pumps Mixers Strainers Engineered Systems and Controls jacketed molten sulfur PumPs PumPs for molten sulfur and other fluids requiring pumping at controlled temperatures. www.haywardgordon.com introduction

More information

Disc Valve Hydraulic Motors 4000 Compact Series

Disc Valve Hydraulic Motors 4000 Compact Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Port B Port A Features Shuttle Valve with Back- Pressure Relief Valve Highlights

More information

LYCOMING A Textron Company

LYCOMING A Textron Company LYCOMING AEIO-360-HB PARTS CATALOG This illustrated parts catalog contains a complete parts listing for the Lycoming AEIO-360-HB wide cylinder flange crankcase model aircraft engines. Major assembly and

More information

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL 1 TECHNICAL SPECIFICATION FOR 400V, 750 kva D.G. SET 1.0 SCOPE This specification covers the

More information

PRODUCT OBSOLETED 1Q16

PRODUCT OBSOLETED 1Q16 VIKING HEAVY DUTY PUMPS FEATURES Section 6 Page 6. Issue C 9 SERIES 27 s Cutaway View (Packed Type) 60-200-280 GPM Sizes (36-45-64 m³/hr) Shown without over-pressure relief valve MECHANICAL SEAL (SERIES

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen is an

More information

Series CC Condensate Units

Series CC Condensate Units Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date

More information

Technical Specification

Technical Specification Technical Specification including performance data Project 3 x 9CM25 rev 2. consisting of 3 Caterpillar Diesel Generator sets Type 9CM25 with site output of: 2475 bkw at each engine flywheel rated 750

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control Data sheet DS/A/UP EN Rev K Models UP1/2/3/4/5/6/7 Measurement made easy High performance actuators for precision damper control Wide range of torque ratings Seven actuator sizes available in ratings from

More information

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Disc Valve Hydraulic Motors 2000 Series

Disc Valve Hydraulic Motors 2000 Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.

More information

EN. 850 Filtrate Pumps. Technical Specification Pages

EN. 850 Filtrate Pumps. Technical Specification Pages 850 17.01.EN 850 Filtrate Pumps Technical Specification Pages 850 Series Filtrate Pump 850 17.01.EN This page left intentionally blank. 1.0 Overview. The 850 is Carver s filtrate pump line designed for

More information

SUPPLEMENT TO NO. 105

SUPPLEMENT TO NO. 105 SUPPLEMENT TO Model 0-30 Series Aircraft Engines Parts Catalog NO. 05 This supplement is provided to inform users of Lycoming parts catalogs of changes, deletions, additions and supersedures that have

More information

Cummins Techical Operations

Cummins Techical Operations Cummins Techical Operations ENGINE MODEL 6BTA5.9-C180 CURVE & DATASHEET FR91536 REV 00 15JUL2006 Basic Engine Model: 6BTA5.9-C180 Engine Performance Curve Engine Family: CPL Code: D40 8541 Displacement:

More information

MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK

MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK JAMISON DOOR COMPANY P.O. BOX 70 HAGERSTOWN, MARYLAND 21740 1-800-532-3667 301-733-3100 INTERNET: http://www.jamisondoor.com E-MAIL: contact@jamisondoor.com ECN

More information

INSTRUCTION MANUAL AND PARTS LIST FOR A3D SERIES PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR A3D SERIES PUMPS TM INSTRUCTION MANUAL AND PARTS LIST FOR A3D SERIES PUMPS WARNING This Instruction Manual and General Instructions Manual SRM00046, should be read thoroughly prior to pump installation, operation or maintenance.

More information

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx. Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah 84047 (801) 566-5678 Ph. (801) 566-7745 Fx. New 850 kw Prime Power Natural Gas Generator Set Approval Status: Energetech s Packager is an Approved

More information

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support Bulletin C 1.4.43 Dean Pump Division Heavy Duty, High Temperature Process Pumps R4140 Telescoping Guard R4140 C-Face Motor Support Dean Pump Series R Centrifugal Process Pumps Capacities to 5000 GPM (1135

More information

DIESEL GENERATOR SET. 60 Hz FEATURES

DIESEL GENERATOR SET. 60 Hz FEATURES DIESEL GENERATOR SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

Installation and Operating Manual

Installation and Operating Manual . Installation and Operating Manual WE/XE-690, 1350, 1700, 2640, 4400, 5200, 6900, 10500 17500, 25690 1 (Rev. 020113) IOM8011.docx . Table of Contents Introduction Page Safety Instructions..... 3 Introduction

More information

VALVITALIA VALVE OPERATORS

VALVITALIA VALVE OPERATORS A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. VALVITALIA VALVE OPERATORS 1 VALVITALIA AUTOMATION DIVISION PROFILE Valvitalia Automation Division manufactures all type

More information

Illustrated Parts Manual

Illustrated Parts Manual Illustrated Parts Manual Models 522D LoPro 524D LoPro S/N 0900 P/N - 948-403 Revised July 6, 2007 INTRODUCTION Table of Contents SECTION INTRODUCTION Table of Contents... - thru -4 Alphabetical Index...

More information

EMERGENCY GENERATOR SET

EMERGENCY GENERATOR SET PART 8.1: EMERGENCY GENERATOR SET PART 1 - GENERAL I SCOPE A. This specification covers the design, furnishing, installation and start up of a factory built, production tested, operable, liquid cooled

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Roots* Centrifugal Compressors

Roots* Centrifugal Compressors GE Energy Roots* Centrifugal Compressors GE continues a history of innovation and technical leadership 2 GE Energy is a global leader in the design and manufacture of air and gas handling solutions. GE

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications ROGERS MACHINERY COMPANY, INC WATER-COOLED, OIL-FREE AIR COMPRESSOR Frame 00 20-50 HP 2110_00.doc Effective: 03/24/17 Supersedes: 10-11-13 Page 1 of 8 1. SPECIFICATION

More information

Disc Valve Hydraulic Motors Series 6000

Disc Valve Hydraulic Motors Series 6000 Disc Valve Hydraulic Motors Series 6000 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Features 9 displacements available Presents a multitude

More information

NATURAL GAS CONTINUOUS (FOR CHP APPLICATION) 2000 ekw 2500 kva 50 Hz 1500 rpm 400 Volts

NATURAL GAS CONTINUOUS (FOR CHP APPLICATION) 2000 ekw 2500 kva 50 Hz 1500 rpm 400 Volts GAS GENERATOR SET NATURAL GAS CONTINUOUS (FOR CHP APPLICATION) 2000 ekw 2500 kva Image shown may not reflect actual package Caterpillar is leading the power generation marketplace with Power Solutions

More information

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer L P & N A T U R A L G A S G E N E R A T O R S E T S STANDBY PRIME 60 Hz 100 kw 80 kw Model Standby kw (kva) Prime kw (kva) Natural Natural G100F3 100 (125) 85 (106.3) G90F3S 90 (90) 80 (80) G100F3S 100

More information

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor HP30 Motor Design code -003 Displacements cm 3 /r [in 3 /r] 344 [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] Engineered for performance For the past 55 years, Char-Lynn has been recognized as the

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs Bulletin BX-1H Bell & Gossett Series HSC-S Pumps Technical Bulletin Part of the Bell & Gossett Equipment Selection Programs TABLE OF CONTENTS Useful Pump Formulas...............................................

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Dresser-Rand Steam Turbines Archived 10/2002

Dresser-Rand Steam Turbines Archived 10/2002 Industrial & Marine Turbine Forecast Dresser-Rand Steam Turbines Archived 10/2002 Outlook Worldwide emphasis on the benefits of combined-cycle power will keep D-R steam turbine production active, albeit

More information

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2 BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR 1.00.00 GENERAL 1.01.00 Make : Jinan Power Equipment Factory 1.02.00 Type : WX21Z-073LLT 1.03.00 Reference Standard : GB/T7064-2002

More information

PWH API 610 SINGLE STAGE OH2

PWH API 610 SINGLE STAGE OH2 PWH API 610 SINGLE STAGE OH2 PWH API 610 PROCESS PUMP HYDRAULIC PERFORMANCE COVERAGE 60 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain

More information

PWH API 610 SINGLE STAGE OH2

PWH API 610 SINGLE STAGE OH2 PWH API 610 SINGLE STAGE OH2 PWH API 610 PROCESS PUMP HYDRAULIC PERFORMANCE COVERAGE 60 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain

More information

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts Designed to match performance and output characteristics of Caterpillar diesel engines Two-thirds pitch minimizes harmonic distortion and facilitates parallel operation DIESEL GENERATOR SET PRIME 220 ekw

More information

CENTAC C700 Start-Up Services

CENTAC C700 Start-Up Services CENTAC C700 Start-Up Services Notes: (1) This packet includes: (a) the Centac Start-up form used by the Field Technician during start-up services; (b) the Installation Planning Checklist that is used prior

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information