Moving Coil Indicators with direct temperature sensor input
|
|
- Helen White
- 5 years ago
- Views:
Transcription
1 Data Sheet 10/ EN Rev. A Moving Coil Indicators with direct temperature sensor input Inputs Resistance thermometers, resistance-type remote sensor (thermocouples on request) Formats Square indicators 72 x 72 mm, 96 x 96 mm Class 1.5 Excellent environmental and mechanical capabilities
2 Moving Coil Indicators With Direct Temperature Input 10/ EN General data Standards The indicators comply with DIN EN 600 and with the safety regulations according to DIN EN In the sections below you can find a short description of the most important parts of these regulations regarding the construction and the characteristics of electrical measuring instruments. Measured error The measured error of an indicator or its accessories is given by the limits through basic errors and effects. The indicators comply with Class 1.5, if no other measured error rating has been given for specific types. Optionally, the indicators can also be supplied for higher class measured errors, as far as this is possible. The class involved is always stated on the scale. Mounting orientation Generally, the nominal position is indicated by a position symbol. For indicators without such a position identification, the reference range is any vertical or horizontal position. The nominal mounting orientation is 5 in every direction of the reference position. Note that the effect (in addition to the indicated error) must not be greater than 50 % of the respective classified error. General technical specifications Standards DIN EN 600 Measuring ranges see measuring range tables Mounting orientation vertical, if not otherwise stated, 2c (see the illustration) Front panel to DIN Front color: black RAL 9005 Environmental conditions to DIN EN , 2, 5 Conditions Permissible variables normal measuring instruments H, Y, G relatively tropicalized instruments H, V, F Operating temperature C C Relative humidity max. 85 %, but not max. 95 %, but not more than 60 days per more than 30 days per year, otherwise 75 %, annual average 65% (max. temperature +27 C) year, otherwise 85 %, annual average 75% (max. temperature +25 C) Condensation none none : 2: 3: 4: a b c 4 = = Z Mechanical category to DIN EN Vibration = Part 2-6 Normal version Frequency range Hz Acceleration max. 2.5 g No. of cycles 5 Runtime 1 octave per minute Shock = Part 2-27 Normal version Acceleration max. 15 g Time of action 11 ms Temperature effect If not otherwise stated, the reference temperature is 23 C ± 2 K for indicators of Class 0.5 to 5. The additional error for a nominal range of ±10 K within this temperature range must not exceed the classified error. Front dimensions 72 x x 96 Scale length (mm) Class Weight (kg) Operating voltage according to DIN Measuring voltage category CAT III CAT III Degree of pollution 2 2 Type of protection IP 52 IP 52 Mounting Screwed bracket Screwed bracket Housing material Sheet steel Sheet steel Scale and pointer design The scales and pointers for square, circular, vertical or horizontal scales comply with DIN 43802, Parts 2 and 4. Type of protection If not otherwise specified, the indicators comply with DIN EN IP 52 for case IP 00 for terminals 2
3 Moving Coil Indicators With Direct Temperature Input 10/ EN Measuring circuit with Ω amplifier Input resistance thermometer Pt100 to DIN EN 607, Ni100 to DIN or resistance teletransmitter Measuring range from ΔR = 10 Ω...1 kω Thermometer current with ΔR 15 Ω approx. 5 ma with ΔR > 15 Ω approx. 3 ma Line balancing for two-wire circuit 1 x 10 Ω for three-wire circuit 3 x 3 Ω calibrated for balancing in the range between Ω for symmetric line resistances (balancing and test resistors are available for an extra charge ) Reference conditions Ambient temperature 23 C ± 2 K Indication Scale graduation rough Pointer Bar pointer, edged Voltage tolerances of the power supply DC V AC V AC V AC V Mechanical construction Front dim. (mm) h Cutout dimensions Mounting depth Connections a c b 72 x ,7 x 68 +0,7 62 mm M4 96 x ,8 x 92 +0,8 62 mm M4 Dimensional drawings Basic dimensions (mm) 5 Panel cutout a c a b c Connection diagrams Three-wire circuit Max. feed line resistance 50 Ω per line. Max. feed line effect 0.5 %/10 Ω Two-wire circuit Max. feed line resistance 10 Ω (feed plus return wire ); external balancing required. Line resistance10 Ω calibrated, the existing line resistance must be increased until reaching 10 Ω by inserting R, (see connection diagrams) Thermocouple connection on request 3
4 Moving Coil Indicators With Direct Temperature Input 10/ EN Ordering information Moving Coil Indicator 1) Variant digit No. 1-9 Code for Temperature Catalog No. H72-X 72 x 72 mm V30462AV- H96-X 96 x 96 mm V30463AV- Measuring Input for Resistance Thermometers Pt100 IEC please indicate range code P Ni100 DIN please indicate range code N Teletransmitter please indicate range code Q Different input signal (thermocouples on request) ZAM Wiring 2-wire connection AN1 3-wire connection AN2 Scale Scale corresponding to range ZSA Scale 0 100% ZSP Scale without graduation start/end marked with symbol bar and company logo ZSN Customized scale (clear text and code No. ZEM) ZEM Power Supply 24 V DC without electrical isolation EV1 24 V DC with electrical isolation EV3 24 V AC EV4 115 V AC EV5 230 V AC EV6 1) other formats on request 4
5 Moving Coil Indicators With Direct Temperature Input 10/ EN Codes for resistance thermometers/teletransmitters Resistance thermometer Teletransmitter Range Pt100 Ni100 Range Pt100 Ni100 Range Code C P20 N C P76 x W Q C P22 N C P81 x W Q C P23 N C P83 x W Q C P24 x C P12 N12 different Q C P25 N C P10 N C P26 x C P11 N C P28 x C P06 x C P30 x C P02 x C P32 x different P99 N C P34 x C P61 x Code Additional ordering information Code Scale sector (color) (clear text) ZPF Red mark at: (clear text) ZPR Additional numbers (clear text) ZZB Additional text (clear text) ZZA Front panel RAL 7032 (pebble gray) ZGH Front panel RAL 7037 (dusty gray) ZGG Mounting orientation (clear text) ZGE Low-reflection pane ZGB Terminal cover IP 20 ZOK Case identification (clear text) ZGJ Category 2/3 (vibration-proof) ZAA Climate group 2 (relatively tropicalized) ZAK Marine version acc. to BV 0591 ZPM Design according to GL certificate ZOM 5
6
7
8 Contact us ABB Ltd. Process Automation Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Phone: +44 (0) Fax: +44 (0) ABB Inc. Process Automation 125 E. County Line Road Warminster PA USA Phone: Fax: Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved 3KXJ100003R / EN Rev. A ABB Automation Products GmbH Process Automation Borsigstr Alzenau Germany Phone: Fax:
Shut-off valves and accessories for pressure measuring instruments
Data Sheet 10/14-4.31-EN Shut-off valves and accessories for pressure measuring instruments Non-replaceable seat and plug Application Shut-off valves for pressure measuring instruments are designed for
More informationModel WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise
Data Sheet DS/WEP-EN Rev. C Model WEP Electro-pneumatic positioner WEP positioner A valve control without compromise Standard - ma input Single acting, force-balance operating principle Excellent dynamic
More informationEAS822 (Contrac) Power Electronic Unit
Contents Data Sheet Rev. A EAS822 (Contrac) Power Electronic Unit For continuous control of Contrac actuators PME120 AN and LME620 AN Microprocessor-controlled power electronic unit with integrated frequency
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals
ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept
More informationRSD100 (Contrac) Electrical Linear Actuator
Contents Data Sheet Rev. A RSD100 (Contrac) Electrical Linear Actuator For continuous positioning, Rated force 100 kn (22500 lbf) Electrical actuator for continuous positioning or step control Stallproof
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units
ABB MEASUREMENT & ANALYTICS DATA SHEET Series 4234-500 and 4234-600 Katharometer power supply units 2 SE RIE S 4 23 4-500 AN D 4 23 4-600 K ATHAROME TE R POWE R SU PPLY U NITS DS/4 23 4-E N RE V. F Measurement
More informationRSDE10 / RSDE20 (Contrac) Electrical Linear Actuator
Contents Data Sheet Rev. A RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator For continuous positioning, In explosion-proof design, Rated force 10 kn / 20 kn (2200 lbf / 4400 lbf) Electrical actuator
More informationBRIDGE-BOY Load limitation electronics with 1 or 3 set points
Change from one to two columns Data Sheet DS/BRIDGE-BOY-LCI-EN Rev. A BRIDGE-BOY Load limitation electronics with 1 or 3 set points Electronics with 1 or 3 set points designed, in combination with a load
More informationValve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat
Data Sheet 10/14-5.32-EN Valve Blocks For direct flanging to pressure and differential pressure transmitters Drop-forging housing Replaceable valve seat Valve stem with back-flow seal and crimped valve
More informationControl Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring
Change from one to two columns Data Sheet 10/138.29EN Rev. B Control Valve 23 / 24 Singleseat straightway valve with exchangeable seat ring Size DN 15... DN 100 With pneumatic actuator Verschiedene Gehäusewerkstoffe
More informationABB i-bus KNX DG/S x DALI-Gateway Basic
ABB i-bus KNX DG/S x.64.1.1 DALI-Gateway Basic The lamps are variably controlled via KNX per DALI output via Broadcast (all lamps jointly) 16 lighting groups 64 individual lamps 16 scenes 64 self-contained
More informationFICHA TÉCNICA DE PRODUTO
FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:
More informationEndura AZ10 Oxygen probe Sensor sub-assembly tested spares kit
Information INF15/166 EN Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit Measurement made easy 1 Introduction This publication details how to replace the sensor sub-assembly on an AZ10 oxygen
More informationMini contactors B6, BC6 with 3 pole
Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More informationField IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator
Data Sheet Field IT Actuators & Positioners Intelligent Electric Modulating Actuator Contrac RHD 16000 Electric actuator for continuous duty modulating or pulse input control. Stall proof without the need
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET Electronic unit and accessories Retrofitting on Contrac 2 ELECTRONIC UNIT AND ACCESSORIES RETROFITTING ON CONTRAC DS/CONTRAC/UPGRADE-EN REV. C Options for
More informationM Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS
Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic
More informationABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011
Technical data 2CDC502097D0201 ABB i-bus KNX Product description HIL/S 20.1.1 The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such as Visualizations or Hotel
More informationData Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1
Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns
More informationABB i-bus KNX HIL/S , Hotel IP Link, Bundle
ABB i-bus KNX HIL/S 20.1.1, Hotel IP Link, Bundle Description of product HIL/S 20.1.1 Hotel IP Link, Bundle The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such
More informationSU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489
MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationThe perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster
Application note AN/FLOW/101-EN Rev. A The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster Complete flowmeter instrumentation with a high level of accuracy
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationRedundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies
Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET 9QGPS5500 Wire rope load cell 2 Measurement made easy Low cost load cell specially designed to measure the tension force on hoisting ropes. CE certified
More informationNavigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares
Instruction replacement procedure INS/ANAINST/025 EN Rev. A Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Kit references: flowcell, tundish, flowmeter,
More informationFPD220 meter 2 di Dual-chamber orifice fitting with double isolation
Data sheet DS/FPD220 EN FPD220 meter 2 di Dual-chamber orifice fitting with double isolation Measurement made easy Safety by design Double isolation with visible proofing mechanism meets HSG253 Category
More informationEmergency stops Award winning design
Emergency stops Award winning design Emergency stops Choosing the right emergency stop device is vital in order to increase the safety for your personnel and equipment. ABB has a very wide range of emergency
More informationZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket
Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in
More informationABB measurement & analytics data sheet. Model M26 Manifold line for 266 pressure transmitters
ABB measurement & analytics data sheet Model M26 Manifold line for 266 pressure transmitters Measurement made easy Engineered solutions for all applications 2 M 26 M a n ifol d li n e for 26 6 p r ess
More informationManual motor starter magnetic only MO325
Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF
More informationM Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96
Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET 9QGPS5190 Trough hole (annular) heavy capacity load cell 2 Measurement made easy Annular compression load cell. Low profile for high capacity load cells
More informationSelective main circuit breakers S 750 series Technical Data
Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.
More informationABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems
ABB MEASUREMENT & ANALYTICS DATA SHEET 2867 series ph and Redox (ORP) industrial dip electrode systems 2 28 67 SE RIE S P H AN D R EDOX ( ORP) INDU STRIAL DIP E LE C TRODE SYSTE MS DS/28 67-E N RE V. F
More informationSystem pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications
System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact
More informationSystem pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications
Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationMEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage
More informationModel 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)
Data Sheet DS/266HSH/LowP-EN Rev. B Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART) Engineered solutions for all applications Measurement made easy Base accuracy 0.15
More informationSurge arrester POLIM-C.. HD
DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10
More informationSurge arrester POLIM-H.. ND
DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit
Technical Datasheet SNK649D00 Catalogue Page ZS6-D-PE Screw Clamp Terminal Blocks Double deck with ground circuit - Save space with double deck ground terminal blocks aligned with ZS6-D double deck terminal
More informationLV Capacitors QCap-L series Capacitors for power factor correction
LV Capacitors QCap-L series Capacitors for power factor correction ABB and power quality ABB is a leader in power and automation technologies that enable utility and industry customers to improve their
More informationNF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3
More informationSurge arrester POLIM-H..SD
Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationZS50-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK607D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground - Reliable electrical and mechanical contact with the rail that exceeds the requirements of the IEC 60947-7- terminal
More informationZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral
Technical Datasheet SNK6047D00 Catalogue Page ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Simplify your PE.N connection with ZS35-PE block connected to ZS35-BL through a premounted jumper. SNK6063F004
More informationLow Voltage Systems MNS and MNS is PowerCenter
Low Voltage Systems MNS and MNS is PowerCenter For our customers, it s all about saving space maximizing functionality for power distribution systems while reducing equipment footprint. ABB has answered
More informationZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator
Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse
More informationABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor
ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3
More informationZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets
Technical Datasheet SNK603D00 Catalogue Page SNK6038S00 ZK.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets The flexible solution for fitting the component of your choice in series
More informationZS4-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:
More informationZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator
Technical Datasheet SNK605D00 Catalogue Page SNK60S00 ZK.5-SF-R PI-Spring Terminal Blocks For 5x0 fuses - with blown fuse indicator - Protect your circuits with 5x0 fuse terminal blocks compliant with
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationProduct Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant
Product Brochure Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Introduction General The braking switch serves the purpose of electrical braking a machine in a hydro or pumped
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit
Technical Datasheet SNK6040D00 Catalogue Page SNK604S00 ZK.-D-PE PI-Spring Terminal Blocks Double deck with ground circuit Improve the safety of your installation in the event of a short-circuit thanks
More informationZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit
Technical Datasheet SNK607D00 Catalogue Page SNK607S00 ZS4-D-S-T Screw Clamp Terminal Blocks Double deck with disconnect circuit with test socket screws and feed-through circuit Find the same functionalities
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationZS10-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK606D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses
Technical Datasheet SNK6D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For 5 x 0 and 5 x 5 fuses Protect your circuit with 5x5 and 5x0 fuse terminal blocks, compliant with IEC 607-7-3 standard (fuse
More informationZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses
Technical Datasheet SNK60D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For x 0 fuses - Protect your circuits with x0 fuse terminal blocks compliant with IEC 607-7-3 standard (fuse not supplied with
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet
Specification sheet 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use Ranges : - 100 to 4000 kpa - 1 to 40 bar - 14.5 to 600 psi Base accuracy : 0.2%(BFSL) Piezoresistive
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationZK4-PE PI-Spring Terminal Blocks Ground
Technical Datasheet SNK60D00 Catalogue Page SNK60S00 ZK-PE PI-Spring Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet 1SNK166D001 Catalogue Page ZS-SF1-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied with
More informationZS4-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationService Fieldbus Engineering and Consulting
Change from one to two columns Data Sheet DS/SEE200-EN Rev. B Service Fieldbus Engineering and Consulting Consulting Bus technology & tool consulting Engineering Bus topology design Service Fieldbus Engineering
More informationZS4-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK600D00 Catalogue Page ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail
More informationZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link
Technical Datasheet SNK656D0 Catalogue Page ZS-ST Screw Clamp Terminal Blocks Test disconnect with sliding link - Secure your disconnect operations in control circuits with the robust sliding link operated
More informationSACE Emax 2/ML Low-voltage air circuit breakers for naval applications
LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response
ABB MEASUREMENT & ANALYTICS DATA SHEET AC00 Series Industrial -electrode conductivity cells with rapid temperature response AC00 SE RIE S I N DUST RI AL -ELE C TRODE CONDU C TIV IT Y C E LLS DS/AC CO-E
More informationZP2.5-PE Spring Terminal Block Ground
Technical Datasheet 1SNK162002D0201.indd 08/06/11 ZP2.5-PE Spring Terminal Block Ground Catalogue Page Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail
More information249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h
No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering
More informationZK2.5-D-CH PI-Spring Terminal Blocks Component holder
Technical Datasheet SNK6066D00 Catalogue Page ZK.-D-CH PI-Spring Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK60V004 SNK009F0000 3D CAD outline drawings available on "Control
More informationNavigator 550 Sodium wet-section
ABB MEASUREMENT & ANALYTICS INFORMATION INF13/115-EN REV. B Navigator 550 Sodium wet-section Spares replacement procedures Measurement made easy Navigator 550 sodium wet-section 1 Introduction These procedures
More informationZS35 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK609D00 Catalogue Page ZS3 Screw Clamp Terminal Blocks Feed-through Closed terminal block: - No end section needed, - Optimized rigidity, - Perfectly adapted to solar applications:
More informationABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw
SOLAR INVERTERS ABB string inverters UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS 1.2 to 5.0 kw The new UNODMPLUS singlephase inverter family, with power ratings from 1.2 to 5.0 kw, is the optimal solution for residential
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationZS4-D-CH Screw Clamp Terminal Blocks Component holder
Technical Datasheet SNK6090D00 Catalogue Page ZS4-D-CH Screw Clamp Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK64V004 SNK008F0000 3D CAD outline drawings available on
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections
Technical Datasheet SNK663D00 Catalogue Page SNK667S00 ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections - Recommended for energy markets and highly demanding applications requiring that
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationProduct information. ECOSS Electronic compact starter for wound rotor drives
Product information ECOSS Electronic compact starter for wound rotor drives Controlled and safe start-up of wound rotor drives Electronic compact starters are used when slip-ring motors have to be started
More informationZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections
Technical Datasheet SNK60D00 Catalogue Page SNK605S00 ZK.5-P PI-Spring Terminal Blocks Feed-through with connections Find all the features of the ZK.5 terminal block with the added option of distributing
More information