sensitive simple small From the Leader in Evaporative Light Scattering Detection Grace Davison Discovery Sciences Brochure #531 GEN

Size: px
Start display at page:

Download "sensitive simple small From the Leader in Evaporative Light Scattering Detection Grace Davison Discovery Sciences Brochure #531 GEN"

Transcription

1 sensitive Most sensitive ELSD available simple Easiest to use and maintain small Integrates easily with any HPLC Grace Davison Discovery Sciences Brochure #5 From the Leader in Evaporative Light Scattering Detection GEN Copyright 006 Alltech Associates, Inc.

2 Introduction To ELSD Leading the Way in ELSD Technology for More than 0 Years No one has more experience designing and manufacturing ELSDs than Alltech, now a part of Grace. Our customers' needs continue to drive the evolution of our ELSD design and development programs. 985 MK II 988 MK IIA 99 MK III 994 MK IIIA 996 ELSD ELSD LTA 000 ELSD ELSD ELSD 000ES ELSD* *patent pending ELSD Advantages Universal Have confidence you re seeing everything in your sample Improve quantitative measurements Estimate purity more accurately Sensitive Detection limits in the low nanogram range Gradient Compatible Maintain stable baselines during steep gradients Alltech ELSDs simplify analysis of difficult compounds: pharmaceuticals impurities phospholipids fatty acids surfactants nutraceuticals excipients amino acids triglycerides polymers carbohydrates ELSD Detection Process:. Nebulization Column effluent passes through a needle and mixes with nitrogen gas to form a dispersion of droplets.. Evaporation Droplets pass through a heated drift tube where the mobile phase evaporates, leaving a fine mist of dried sample particles in solvent vapor.. Detection The sample particles pass through a cell and scatter light from a laser beam. The scattered light is detected, generating a signal. Copyright 006 Alltech Associates, Inc.

3 ELSD Advantages ELSD Advantages Over Other LC Detectors ELSD RI UV MS CHART KEY Sensitivity Gradient Capability Baseline Stability Solvent Interference Mass Balance Excellent: Good: Poor: ELSD improves baseline stability and detection sensitivity compared to refractive index (RI) ELSD shows what may be missing from your UV chromatogram Solvent Front Sugar Alcohols. Xylitol (00ppm). Sorbitol (00ppm). Dulcitol (00ppm) Plant Oil Extract ELSD ELSD RI Min. UV at 54nm Min. Column: Alltech Prevail Carbohydrate ES, 5µm, 50 x 4.6mm, (Part No. 50) Mobile Phase: Acetonitrile:Water (79:) Flow Rate:.0 ml/min Column Temp: 0 C Use ELSD in parallel with UV/Vis and MS for maximum structural and concentration information Column: Alltech Alltima C8, μm, 50 x.mm, (Part No. 485) Mobile Phase: A: 0.% Formic Acid B: Methanol Gradient: Time: 0 40 %B: Flow Rate: 0.5 ml/min Column Temp: 0 C ELSD obtains a more accurate representation of sample mass than UV/Vis Steroid Hormone Formulation. Povidone (8 µg). Chlormadinone Acetate (.5 µg). Mestranol ( µg) Min. ELSD MS UV at 54nm Mephobarbital (500ppm). Secobarbital (500ppm) : Mixture Min. ELSD UV at 0nm Column: Vydac Denali 8DE C8, µm, 50 x.mm, (Part No. 8DE05) Mobile Phase: 0.% Formic Acid in Acetonitrile:Water (55:45) Flow Rate: 0. ml/min Column: Alltech Alltima HP C8 HL, 5µm, 50 x 4.6mm, (Part No ) Mobile Phase: Acetonitrile:Water (0:70) Flow Rate:.0 ml/min Column Temp: 45 C Copyright 006 Alltech Associates, Inc.

4 Sensitive & Reproducible With reduced noise and greater baseline stability, the 00 ELSD is more sensitive than any other ELSD available. Methyl Paraben (00ng). Propyl Paraben (00ng). Butyl Paraben (00ng) Competitor S Competitor P Competitor W Butyl Paraben Model Limit of Detection (LOD) 00 ELSD 5ng Competitor S Competitor P Competitor W Competitor X 00ng 00ng 50ng 50ng Competitor X 00 ELSD Column: Alltech Alltima C8, 5µm, 50 x 4.6mm, (Part No ) Mobile Phase: Water:Acetonitrile (40:60) Flow Rate:.0 ml/min Min. The 00 ELSD's near ambient temperature evaporation maximizes sensitivity for semi-volatiles The 00 ELSD is very reproducible as demonstrated by 0 identical injections of four ginkgolide components. Ibuprofen (00ppm) Component % RSD. Bilobalide.7. Ginkgolide C.. Ginkgolide A.6 4. Ginkgolide B.0 0 Min. 0 C.5 C 5 C 7.5 C 40 C 4.5 C Column: Alltech Alltima HP C8, µm, 00 x.mm, (Part No ) Mobile Phase: Acetonitrile: 0.%TFA in Water (80:0) Flow Rate: 0. ml/min Min. Column: Alltech Platinum C8, 5µm, 50 x 4.6mm, (Part No. 064) Mobile Phase: Water:Methanol:THF (65:5:0) Flow Rate:.0 ml/min 4 Copyright 006 Alltech Associates, Inc.

5 Easy To Use A Windows -based user interface makes navigating through menus intuitive and easy. All critical operating parameters and a scrolling chromatogram trace are shown on the large, full color LCD. A simple, step-by-step method wizard guides you through detector setup Select from seven different languages for the user interface: English Español Francais Deutsch Italiano Japanese Chinese An informative help function is available in each screen Additional Features: Control and collect data digitally through Agilent ChemStation and EZchrom chromatography data software Ensure GLP compliance with password protected screen and error log Store up to 00 methods for fast set up Save gas and extend optics lifetime by programming unit to enter stand by mode at end of run coming soon Copyright 006 Alltech Associates, Inc.

6 Easy To Maintain Maintenance Made Simple! Parts requiring cleaning or service are accessible from the front Remove the nebulizer with a simple twist and pull Clean the drift tube easily with the included custom brush Onboard diagnostics automate the troubleshooting process Full IQ/OQ/PQ Protocols Included with each ELSD We make it easy for you to integrate the ELSD into a qualified HPLC system. The 00 ELSD is thoroughly tested before shipment and calibration and performance documents are included with each instrument. Detailed IQ/OQ/PQ procedures are included with the detector to help you perform your own qualification. We also provide the option of onsite qualification performed by one of our service engineers. Copyright 006 Alltech Associates, Inc.

7 Applications Stable Baselines with Fast, Steep Gradients 0 Min.. Acetylsalicylic Acid. Diphenhydramine. Trimipramine 0658 Column: Alltech Alltima HP C8, µm, x 7mm, (Part No. 8767) Mobile Phase: A: 0.%TFA in Water B: 0.% TFA in Acetonitrile Gradient: Time: 0 %B: 0 90 Flow Rate:.5 ml/min Column Temp: 0 C Simplify Detection of Weak Absorbing Polymers. mpeg-sba 066 Use ELSD to Trigger Collection of UV Transparent Compounds in Prep Applications ,8 9, Min. Column: Vydac Denali 8DE C8, 0µm, 50 x mm, (Part No. 8DE05) Mobile Phase: A: Acetonitrile B: Dichloromethane Gradient: Time: %B: Flow Rate: 0 ml/min Column Temp: 5 C. LLLn. LLL. LLO 4. PLL 5. LOO 6. PLO 7. PLP 8. OOO 9. SLO 0. POO 0679 Easily Detect Non-Chromophoric Drug Compounds Spectinomycin Min. Column: Alltech ProSphere 00, 5µm, 50 x 4.6mm, (Part No. 5560) Mobile Phase: A: Water B: Acetonitrile Gradient: Time: 0 5 %B: Flow Rate:.0 ml/min Detect Difficult Samples without Derivatizing Biodiesel Derived from Soy Bean Oil Min Mono-acylglycerol (MAG). MAG. MAG 4. Fatty Acid Methyl Ester (FAME) 5. MAG 6. FAME 7. FAME 8. MAG 9. FAME 0. Di-acylglycerol (DAG). Tri-acylglycerol (TAG) Column: Alltech Alltima HP C8 HiLoad, 5µm, 50 x 4.6mm, (Part No ) Mobile Phase: A: Acetonitrile B: Dichloromethane Gradient: Time: %B: Flow Rate:.0 ml/min Min. Column: Alltech Alltima HP C8 Amide, µm, 50 x 4.6mm, (Part No. 8789) Mobile Phase: 0mM Ammonium Carbonate:Acetonitrile (98:) Flow Rate:.0 ml/min Improve Sensitivity for Carbohydrates Robitussin Flu Syrup Min. Column: Alltech Prevail Carbohydrate ES, 5µm, 50 x 4.6mm, (Part No. 50) Mobile Phase: A: Acetonitrile B: Water Gradient: Time: %B: Flow Rate:.0 ml/min Sucralose. Fructose. Sorbitol 4. Glucose 5. Sucrose 6. Maltose Copyright 006 Alltech Associates, Inc.

8 Ordering Information Description Alltech 00 ELSD* Part No. 00 ELSD 0V 40V 5584 *Patent Pending Description Services for the Alltech 00 ELSD Installation and Training Qualification IQ/OQ at Customer Site PQ at Customer Site IQ/OQ/PQ at Customer Site Part No. INSTALL Q000 Q000 Q000 Our dedicated applications chemists and technical support professionals are constantly adding new applications to our vast technical library. Visit to search and download applications or one of our applications brochures. Lipids Carbohydrates Pharmaceuticals Alltech 00 ELSD Specifications Light Source: Laser diode with collimating optics, 650nm, 0mW output, class IIIB Detector Element: Silicon photodiode Temperature Range: Ambient to 0ºC in ºC increments Nebulizer Gas: Nitrogen preferred; Calibrated to 4.0L/ min Inlet Pressure: 60 80psig Typical Operating Range:.0.0L/min Flow Control: Digital Mass Flow Control Mobile Phase Flow Rate: To.0mL/min Analog Output: V or 0mV full scale Communications: Inputs: TTL/contact closure for auto zero, gas shutoff, start, and standby Outputs: Contact Closure for pump shutdown in error conditions, general events Data Ports: USB, RS, Ethernet User Interface: Full color Microsoft Windows based Graphical LCD with alphanumeric keypad Power Requirements: 0/40V, 50/60Hz Dimensions:.6" H x 0." W x 9.5" D (9.5cm H x 6.cm W x 49.5cm D) Weight: 0lbs (6Kg) IEC/FDA Classification: Class Laser Product; Complies with CFR Subpart J Manufacturing Standards: Meets all applicable safety and EMC certifications; CE, UL, and CSA certified Warranty: year parts and labor See how the 00 ELSD can benefit your analysis! Visit and click on "Contacts". Ask about sample analysis or a product demonstration in your lab. ALLTECH, ALLTIMA, DENALI, FLEXIT, GROM, JONES CHROMATOGRAPHY, MODCOL, PLATINUM, PREVAIL, PROSPHERE, and VYDAC are trademarks, registered in the United States and/or other countries, of Alltech Associates, Inc. DAVISIL, GRACE and GRACE DAVISON DISCOVERY SCIENCES are trademarks, registered in the United States and/or other countries, of W. R. Grace & Co.-Conn. MICROSOFT WINDOWS and WINDOWS are trademarks, registered in the United States and/or other countries, of Microsoft Corporation. ROBITUSSIN is a trademark, registered in the United States and/or other countries, of American Home Products Corp. This trademark list has been compiled using available published information as of the publication date of this brochure and may not accurately reflect current trademark ownership. Grace Davison Discovery Sciences is a product group of W. R. Grace & Co.-Conn. Alltech Associates, Inc. is a wholly owned subsidiary of W. R. Grace & Co.-Conn. Copyright 006 Alltech Associates, Inc. All rights reserved. The information presented herein is derived from our testing and experience. It is offered, free of charge, for your consideration, investigation and verification. Since operating conditions vary significantly, and since they are not under our control, we disclaim any and all warranties on the results which might be obtained from the use of our products. You should make no assumption that all safety or environmental protection measures are indicated or that other measures may not be required. This product(s) may be covered by patents or patents pending. Grace reserves the right to change prices and/or specifications without prior notification. Printed in the USA. Grace Davison Discovery Sciences Headquarters 05 Waukegan Road Deerfield, Illinois Tel: Fax: contact.alltech@grace.com Web: 09/06 #5 Grace Davison Discovery Sciences Copyright 006 Alltech Associates, Inc.

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE AN HPLC THAT WORKS AS HARD AS YOU DO Confidence in your results comes with high performance, day-to-day reliability, and overall system robustness.

More information

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Giorgis Isaac, 2 and Larry T. Taylor 1 1 Department

More information

Stability Axial Compression Technology Application Ordering Information

Stability Axial Compression Technology Application Ordering Information 42 YMC-Actus YMC-Actus 43 YMC-Actus Contents Stability... 44 Axial Compression Technology... 45 Application...46-47 Ordering Information...48-49 Introduction Fast semi-preparative chromatography Semi-preparative

More information

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution Application ote Small Molecule Pharmaceuticals Author Sonja Schneider Agilent Technologies,

More information

A Single Method for the Direct Determination of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection

A Single Method for the Direct Determination of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection A Single Method for the Direct Deteration of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection Marc Plante, Bruce Bailey, Ian N. Acworth, Christopher Crafts, Thermo

More information

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad

More information

Prep Flash TLC. Preparative Chromatography

Prep Flash TLC. Preparative Chromatography Prep Flash TLC Preparative Chromatography........ 148 183 Introduction...................... 148 151 Columns....................... 152 171 GraceAlpha Columns 152 155 Vydac MS Columns 156 157 Vydac TP

More information

S 1125 HPLC Pump System

S 1125 HPLC Pump System Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make

More information

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract. Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources

More information

HPLC SYSTEM S 500 SERIES

HPLC SYSTEM S 500 SERIES HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options

More information

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell Application Note Consumer Products Authors Gerd Vanhoenacker,

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

Application Note. Author. Introduction. Energy and Fuels

Application Note. Author. Introduction. Energy and Fuels Analysis of Free and Total Glycerol in B-100 Biodiesel Methyl Esters Using Agilent Select Biodiesel for Glycerides Application Note Energy and Fuels Author John Oostdijk Agilent Technologies, Inc. Introduction

More information

VERITY Purification Systems Build the perfect system to fit your research

VERITY Purification Systems Build the perfect system to fit your research VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC

More information

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany Determination of Aromatic Hydrocarbons in Petroleum Middle Distillates with the Agilent Infinity Binary HPLC System with RID Detection According to IP9()/ASTM D9 Application Note Energy & Chemicals - Petrochemicals

More information

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Technical Note This Technical Note describes the purpose, installation, and configuration and use of a diverter valve

More information

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide Accuracy Starts Here Agilent Captiva Filtration Selection Guide TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video

More information

ACQUITY UPLC I-Class System with 2D Technology

ACQUITY UPLC I-Class System with 2D Technology ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize

More information

HPLC System S 600 Series

HPLC System S 600 Series HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Joan M Stevens, Ph.D., Mark Crawford and Greg Robinson Single Presenter Name Abstract:

More information

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Application Note Hydrocarbons Authors Michael Woodman Agilent Technologies, Inc. Chemical Analysis Solutions 2850

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method 2016 International Conference on Applied Mechanics, Mechanical and Materials Engineering (AMMME 2016) ISBN: 978-1-60595-409-7 Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel

More information

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville

More information

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications C196-E081C Ultra High Performance Liquid Chromatograph Nexera X2 Specifications Specifications System Controllers CBM-20A / 20Alite CBM-20A (228-45012-XX) CBM-20Alite (228-45011-XX) Connectable units Solvent

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

InfraCal 2 Biodiesel Blend Analyzer

InfraCal 2 Biodiesel Blend Analyzer InfraCal 2 Biodiesel Blend Analyzer Model ATR-B User s Guide InfraCal and Wilks are registered trademarks of Wilks Enterprise, Inc. Copyright 2013 Wilks Enterprise, Inc., East Norwalk, CT WilksIR.com Rev.

More information

Liquid Chromatography

Liquid Chromatography SCINTOMICS Liquid Chromatography Always the right system for your needs. SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative

More information

Analyte Focusing in Elevated Temperature HPLC

Analyte Focusing in Elevated Temperature HPLC Analyte Focusing in Elevated Temperature HPLC Jody Clark Brian Jones, Stephanie J. Marin, Dale Felix Selerity Technologies, Inc. Salt Lake City, UT 84104 www.selerity.com Introduction HPLC at extreme temperatures

More information

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership. MB3000 Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership. MB3000 FT-IR Analyzer designed for research and development Our company needs versatility

More information

5 µm Preparative HPLC Columns

5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns Your only as good as your last product. ~ James Browne, Continuous Improvement Program Manager/Lean/6-Sigma Program Manager, Wexford, Ireland

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Simulated Distillation Analyzers, Software, Standards, Consumables, Training Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to

More information

Determination of Sudan Dyes I IV in Curry Paste

Determination of Sudan Dyes I IV in Curry Paste Determination of Sudan Dyes I IV in Curry Paste Suparerk Tukkeeree and Jeffrey Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 23 Key

More information

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584 Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN 14105 and ASTM D6584 Introduction With today s increasing concern for the environment and the depletion of fossil

More information

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over The Agilent 12 Series high performance autosampler SL: Area precision, injection volume linearity, imum accessible volume, carry-over Technical Note 8 6 4 2.5 1 Introduction A main performance criterion

More information

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director Quality-by-Design in Method Development Mijo Stanic General Manager and Technical Director Agenda Chromicent who we are Traditional vs. Systematic strategies for method development QbD a new approach in

More information

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D* Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY 21 CFR Part 11* 98/79/EC IVD-D* 02 Innovative. Sustainable. Smart The Infinite F50 is Tecan s next generation,

More information

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

Infinite F50 family Reliable. Validated. Compact.

Infinite F50 family Reliable. Validated. Compact. Infinite F50 family Reliable. Validated. Compact. Innovative 8-channel absorbance readers with advanced LED technology 21 CFR Part 11* 98/79/EC IVD-D* Infinite F50 Innovative design with top price-performance

More information

PrimeLine TM HPLC Pumps

PrimeLine TM HPLC Pumps PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design

More information

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Application Note Energy and Fuels Authors Detlef Wilhelm Anatox GmbH & Co. KG Fürstenwalde, Germany Udo Huber Agilent

More information

Determination of Free and Total Glycerin in B100 Biodiesel

Determination of Free and Total Glycerin in B100 Biodiesel Page 1 of 5 Page 1 of 5 Return to Web Version Determination of Free and Total Glycerin in B100 Biodiesel By: Michael D. Buchanan, Katherine K. Stenerson, and Vicki Yearick, Reporter US Vol 27.1 techservice@sial.com

More information

HIGH PRESSURE SWITCHING VALVES

HIGH PRESSURE SWITCHING VALVES HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available

More information

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011 Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc.

More information

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD. Infinity II - Standard Preventive Maintenance Service Agilent Preventive Maintenance (PM) provides factory recommended service for your systems to assure reliable operation and the accuracy of your results.

More information

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability PMA 5 Pensky-Martens Flash Point Tester ::: Volatility... Flammability A Tradition of Competence 140 years of developing, producing and supporting excellent flammability instruments. 140 years of technology

More information

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN1413:211 Method Application Note Author James D. McCurry, Ph.D. Agilent Technologies Abstract

More information

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE gilent InfinityLab LC urification Solutions SELECTION GUIDE GILENT INFINITYLB LC URIFICTION SOLUTIONS EFFICIENT LC URIFICTION SOLUTIONS FOR NLYTICL TO RERTIVE SCLE gilent InfinityLab LC urification Solutions

More information

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN Fang Xia, Jie Y. Cavanaugh, Darcy Shave, Gary Izzo, Michael Savaria, Thomas Grady, Markus Wanninger, Donald Ziniti, Brad Francis,

More information

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems Meeting the Requirements of ASTM D 6591-06 ( IP548/06 ) with Agilent 1200 LC Systems M.Woodman, Chemical Analysis Solutions Unit, Wilmington, Delaware, USA M.Sierocinska, European Field Support Centre,

More information

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY STATIC HEADSPACE SAMPLER SHS HISTORICALLY HISTORICALLY THE THE BEST BUST A ROBUST AND FLEXIBLE SYSTEM TO SYSTEM MEET COMPLEX TO AND VERSATILE MEET NEEDS COMPLEX AND LIABLE RESULTS AND RELIABLE RESULTS

More information

Turbidity and Suspended Solids Transmitter

Turbidity and Suspended Solids Transmitter Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56

More information

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features Smart-UPS On-Line Lithium Ion UPS 230V Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features A UPS developed for availability of your most critical loads under

More information

Mistral LC-MS Evolution Specification

Mistral LC-MS Evolution Specification Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature

More information

ACQUITY UPLC I-Class System Specifications

ACQUITY UPLC I-Class System Specifications ACQUITY UPLC I-Class System s Revision A Copyright Waters Corporation 2011 All rights reserved Copyright notice 2011 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA AND IN IRELAND. ALL RIGHTS

More information

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of

More information

AppNote 1/2010 KEYWORDS ABSTRACT. Biodiesel, Automation, ASTM D

AppNote 1/2010 KEYWORDS ABSTRACT. Biodiesel, Automation, ASTM D AppNote 1/2010 Full Automation of ASTM Method D6584-07 Standard Test Method for the Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography using a GERSTEL Dual

More information

Supercritical CO2 (SCCO2) Cleaning of Space Precision Assemblies at Raytheon Missile Systems

Supercritical CO2 (SCCO2) Cleaning of Space Precision Assemblies at Raytheon Missile Systems Supercritical CO2 (SCCO2) Cleaning of Space Precision Assemblies at Raytheon Missile Systems Hunter L. Rosen, Presenter (1) Paul W. Fecsik (2) 1 M&P Engineer Raytheon Missile Systems M&P Engineering Manufacturing

More information

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve Online sample cleanup on the Agilent 129 Infinity LC using a built in 2-position/6-port valve Analysis of Sudan red compounds in paprika powder Application Note Food Authors Angelika Gratzfeld-Huesgen

More information

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.

More information

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements

More information

CONTAMINATION CONTROL FOR LIFE SCIENCE APPLICATIONS

CONTAMINATION CONTROL FOR LIFE SCIENCE APPLICATIONS CONTAMINATION CONTROL FOR LIFE SCIENCE APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Regulatory Compliance Pharmaceutical companies, medical device manufacturers,

More information

AVL Particle Measurement System Aviation

AVL Particle Measurement System Aviation AVL Particle Measurement System Aviation Measurement of non-volatile Particulate Matter mass and number emissions from aircraft turbines according to the AIR6241 MARKET REQUIREMENTS Non-volatile particulate

More information

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment chromatography Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment Product Specifications Thermo Scientific Dionex UltiMate 3000 products are UHPLC compatible by design, establishing

More information

A Rapid imethodtm Test for Analysis of Acid Herbicides in Water

A Rapid imethodtm Test for Analysis of Acid Herbicides in Water A Rapid imethodtm Test for Analysis of Acid Herbicides in Water A Rapid imethodtm Test for Analysis of Acid Herbicides in Water The following description outlines the instrument requirements and expected

More information

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell Alexandra Manka and Holger Franz Thermo Fisher Scientific, Germering, Germany Technical

More information

better analysis counts

better analysis counts better analysis counts Application Areas: Upstream desalting, refining, power generation and effluent management. Total chlorine analysis in: - raw and desalted crudes - water and effluent streams - refinery

More information

Seeker HL Source Transmitter. User s Guide

Seeker HL Source Transmitter. User s Guide Seeker HL Source Transmitter User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without

More information

Bright prospects Solvents for spectroscopy Uvasol

Bright prospects Solvents for spectroscopy Uvasol Bright prospects Solvents for spectroscopy Uvasol EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Simply the best UV/VIS and infrared spectroscopy are reliable and accurate methods

More information

Cooled incubators (ST), laboratory refrigerators

Cooled incubators (ST), laboratory refrigerators Cooled incubators (), laboratory refrigerators The version has been designed for those customers who look for professional lab equipment at a very competitive price. The cooled incubators () and refrigerators

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

Advanced efficiency, precision cooling Design an HVAC system like no other

Advanced efficiency, precision cooling Design an HVAC system like no other VZH, 2 nd generation of inverter scroll compressors Advanced efficiency, precision cooling Design an HVAC system like no other Stand out in the commercial HVAC and process cooling marketplace by boosting

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

MET-Biodiesel Capillary GC Columns

MET-Biodiesel Capillary GC Columns MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What

More information

FLOTTWEG SEPARATION TECHNOLOGY FOR THE PRODUCTION OF BIODIESEL

FLOTTWEG SEPARATION TECHNOLOGY FOR THE PRODUCTION OF BIODIESEL FLOTTWEG SEPARATION TECHNOLOGY FOR THE PRODUCTION OF BIODIESEL ALTERNATIVE FUELS HAVE GOOD PROSPECTS You too Can Benefit from Them! Biodiesel is a fuel produced from natural fats and oils. Its raw materials

More information

Advanced efficiency, precision cooling Design an HVAC system like no other

Advanced efficiency, precision cooling Design an HVAC system like no other VZH, 2 nd generation of inverter scroll compressors Advanced efficiency, precision cooling Design an HVAC system like no other Stand out in the commercial HVAC and process cooling marketplace by boosting

More information

Technical Overview. Introduction

Technical Overview. Introduction Performance characteristics of the Agilent 129 Infinity Binary Pump More resolution and speed for conventional, superficially porous and sub-2 µm column packing material Technical Overview Introduction

More information

TSHR 6000 series TN/TS/TX analyzer

TSHR 6000 series TN/TS/TX analyzer TSHR series TN/TS/TX analyzer Versatile, Accurate and Reliable Trace Level Nitrogen, Sulfur, Chlorine Analysis Petrochemicals Refineries Analytical Services Research Analysis The TSHR series TN/TS/TX Analyzer

More information

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105 Application Note: 10215 Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105 Fausto Munari, Daniela Cavagnino, Andrea Cadoppi, Thermo Fisher Scientific, Milan,

More information

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection Model ED 400 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the

More information

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9 Foreword...xi Acknowledgments...xiii Introduction... xv Chapter 1 Engine Emissions...1 1.1 Characteristics of Engine Exhaust Gas...1 1.1.1 Major Components of Engine Exhaust Gas...1 1.1.2 Units Used for

More information

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS) SPECIFICATION Bench top triple quadrupole Mass performance Chromatography (GC-MS/MS) 1. Scope These specifications describe the requirements for a bench top triple quadrupole mass spectrometry system coupled

More information

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment Measurement & Analytics Measurement made easy MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment FT-NIR optimizing productivity

More information

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses An electronic nose produces a recognizable response based

More information

Specifications for Refrigerants

Specifications for Refrigerants AHRI Standard 700 with Addendum 1 2016 Standard for Specifications for Refrigerants WITH ADDENDUM 1, SPECIFICATIONS FOR REFRIGERANTS September 2016 Addendum 1 (dated September 2016) of AHRI Standard 700-2016,

More information

Advanced efficiency, precision cooling Design an HVAC system like no other

Advanced efficiency, precision cooling Design an HVAC system like no other VZH, 2 nd generation of inverter scroll compressors Advanced efficiency, precision cooling Design an HVAC system like no other Stand out in the commercial HVAC and process cooling marketplace by boosting

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR 6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Introduction P Gorst-Allman (LECO Africa Pty. Ltd) and B-J de Vos (NMISA). The analysis

More information

NEW HPLC - SYSTEM LINE

NEW HPLC - SYSTEM LINE NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent

More information

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent Extended ph range from 1-10 provide longer lifetimes with harsh mobile phases Novel bonding reduces residual silanols which cause peak tailing Polymer coated capsule type silica Excellent selectivity for

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information