Supply Return. Pumping station 2-way "Solar 2" _!':'! _. Directions for the use of the flowmeter to fill the installation:
|
|
- Lindsay Peters
- 5 years ago
- Views:
Transcription
1
2
3 Pumping station 2-way "Solar 2" F+ F+ (C) Security unit The security unit, CE and TUV approved, protects the installatjon from the overpressures. lt is calibrated at 6 bar, over this pressure the security unit starts, lt is also Drovided with a manometer and with a connection to the expansion vessel by a 3/4" flexible kit (optional), see here at the Supply Return (A) Ballvalve on the supply way (thermoter with red ring and scale 0-120"C) with "Sola/' checkball. (B) Ball valve on the return way (thermoter with blue ring and scale 0-120"C) with "Solar" checkball. Solar Checkhall It is included into the ball valve both in the supply way and in the return way. lt ensures the seal and low head losses. To exclude the checkball valve, for instance case ol emptying rotate the handle by 45' clockwise. (D) Flowmeter The flowmeter allows to regulate the flow rate to the capacity of the installation, by a 3-way ball valve. lf the valve is closed the usual circulation is cut off, it is possible to use the side filling tap to flll the installation. There is also another side tap, for the draining. The proximity of the two taps helps these operations minimizing the distance between the filling and the draining. The flow rate is measured and shown by the special sliding cursor: the measurement is immediate thanks to the proximity to the regulation valve. As shown hereinunder three flowmeters are available with different intervals of measurement: 2-12Llmin,8-28 Umin and 8-38 Umin. (E) Circulating pump Three speed circulating pump with manual regulation, Thanks to the seal of the ball valves before and after the circulating pump, it can be removed without emptying the installation. Directions for the use of the flowmeter to fill the installation: Blockin! th. f lling/dr.ln Unscr whe fixing $rew, il again tum ng il ol 180' Flow nte shown (in this case _!':'! _.-,''':L-- (1) - Filling the installation: Remove the plugs from the side valves and connect the hose unions. Close the ball valve and open the side filling valve and draining valve. (2J- Starting the installation working: Open the ball valve and close the side filling and draining valves. Remove the hose unions and screw again the plugs. To avoid any casual opening of the side valves, il is beffer fo sfop the levers in the close posifron, as shown here aside. (3)- Regulate the flow rate using the regulation rod until the right flow rate is shown. lv.b. The flow rate is shown taking as reference the lower edge of the sliding cursor. (see picture)
4 General information Standard quick connection module V1 Connection type PL Capacitor Capacitor Yellow / Green Blue Brown Connection type PR Capacitor Capacitor Brown Yellow / Green Blue 6
5 General information Approved pump mounting arrangements : Viscous fluids / Hydraulic datas All hydraulic datas contained in this catalogue are based on handling water having a kinematic viscosity = 1 mm 2 / s Water / glycol mixtures, max. mixing ratio 1:3. These data are measured after a minimum of 12 hours of running-in. Minimum inlet pressure to prevent cavitation To avoid cavitation (vapour forming within the pump) it is necessary to maintain at the pump suction port an adequately high positive pressure (static head) in relation to the vapour pressure of the fluid being handled. Minimum inlet pressure in psi (m) at the pump suction inlet to avoid cavitation noise at 104 F (+40 C) ambient and max. water temperatures 122 F (50 C) 0.7 psi (0.5 m) 203 F (95 C) 4.4 psi (3.0 m) 230 F (110 C) 14.5 psi (10.0 m) For higher altitudes: add 0.14 psi (0.1 m) head / 328 ft (100 m) height increase. These minimum heads must be respectively increased when handling fluids of higher temperatures or lower densities, higher resistances at the pump suction side and in regions of lower atmospheric pressures. Circulating pump threaded connection Designation A T WILO Pump's section designation Pump's thread diameter (inch) 1" 1½" 2" Pump's thread diameter (mm) 33,25 47,8 59,61 Pipe's diameter (inch) ½" 3/ 4 or 1" 1¼" Pipe's designation (mm) 15/21 20/27 or 26/34 33/42 7
6 General information General reference Permissible ambient air temperatures From 32 F to 140 F - with a fluid temperature not exceeding 203 F (From 0 C to +60 C - with a fluid temperature not exceeding 95 C) Condensation Pumps listed as being suitable of handling chilled water down to 14 F ( 10 C) are fully condensation-proof. Working Pressure Maximum working pressures to which pumps can be internally subjected to are: > pump housing cast iron: PN 10 > pump housing composite : PN 3 or PN 6 (please contact us) Max. fluid temperature > Cast iron pump housing: 230 F (110 C) > Composite pump housing: 203 F (95 C) Terminal box connections > The connecting cable can be led by the client through the packing cable gland on either right or left Electrical Wiring > All Wilo Intec UL pumps are suitable for wiring to the appropriate North American standard voltage 115 V (±10%) Frequency > All Wilo Intec UL pumps operate at 60 Hz as required in North America Replacement Pumps Customers are requested to provide after sales service when replacement pumps are required by their customers in North America. By prior agreement, Wilo North America can provide spares from its stock in Chicago and Calgary for pumps with standard configurations. These are defined as pumps with the following: 3 speeds 5 inch (130 mm) height Terminal box position 9 or 12 o clock for 1 inch connection Terminal box position 9 o clock for STAR U 25 (1.5 inch) and NFSL Packing gland left with cap (plug) on right hand side 16 ft (5 m) U, RSL, NFSL, HU pump housings. 8
7 Heating pump STAR U Type : STAR U STAR S 16 U 15 STAR S 16 U 25 STAR U Pump head (height of water at 0 flow): 16, 21 ft Pump Body: Cast Iron Connections Width: 1, 1 1 / 2, 2 Pump Height: 5 inch (130 mm), 7 inch (180 mm) 1 speed or 3 speed 9
8 Heating pump STAR U Star S 16 U Head (ft) Water flow (m 3 /h) 0 0,5 1 1,5 2 2, Water flow (US gpm) Head (m) Max. Speed Av. Speed Min. speed FLOW HEAD P1 I1 Qm3/h H mwg Watts Amps 1,00 4,7 74,3 0,64 1,00 2,1 64,7 0,59 1,00 0,5 43,7 0,41 Star S 21 U Head (ft) Water flow (m 3 /h) 0 0,5 1 1,5 2 2, Water flow (US gpm) Head (m) Max. Speed Av. Speed Min. speed FLOW HEAD P1 I1 Qm3/h H mwg Watts Amps 1,00 5,0 82,4 0,71 1,00 3,2 67,3 0,62 1,00 1,3 49,3 0,45 10
Pumps Certified for North American Market
Pioneering for You Version 2015/09 Pumps Certified for North American Market Subject to change without prior notice WLO SE Introduction History In 1872, Louis Opländer founded Wilo as a copper a brass
More informationInstallation instruction
1 Safety Before installing the device, please read this manual carefully. Please note that the installation must be executed according to relevant technical rules. The installation must also be adapted
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction
More informationData sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)
Data sheet: Wilo-TOP-S 4/1 (1~23 V, PN 6/1) Pump curves Single-phase current H/m 1 8 v 1 2 3 4 Wilo-TOP-S 4/1 1~23 V - DN 4 5m/s p/kpa 1 8 Approved fluids (other fluids on request) Heating water (in accordance
More informationData sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)
Data sheet: Wilo-TOP-S 4/4 (1~23 V, PN 6/1) Pump curves Single-phase current H/m 4 3 v,5 1, 1,5 2, 2,5 3, Wilo-TOP-S 4/4 1~23 V - DN 4 m/s Approved fluids (other fluids on request) Heating water (in accordance
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationSeries description: Wilo-Stratos ECO-STG
Series description: ()- Design Glandless circulation pump with threaded connection, EC motor and automatic power adjustment Application Primary circuits of solar and geothermal systems Type key Example:
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 Pressure Range: Suction Range: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but
More informationLiquid ring compressors
Liquid ring compressors KPH 65212, KPH 65218 Compression pressures: Suction volume flow: 2 to 7 bar 375 to 660 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationContents. Identification
Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationData sheet: Wilo-Stratos PICO 25/1-6
Data sheet: Wilo-Stratos PICO 25/1-6 Pump curves Δp-c (constant) 5 4 v 1 2 3 4 5 6,5 1, p-c Rp ½ 1,5 2, Rp 1 m/s,4,8 1,2 1,6 Rp 1¼ H/m Wilo-Stratos PICO 15/1-6, 25/1-6, 3/1-6 6 1~23 V - Rp ½, Rp 1, Rp
More informationData sheet: Wilo-Yonos PICO 25/
Data sheet: Wilo-Yonos PICO 25/1-5-13 Pump curves H/m 5 4 3 2 1,4,8 1,2 1,6,5 1, 1,5 2, 2,5 3,,2,4,6,8 2 4 6 8 1 P 1/W 3 2 1 4m p-c Wilo-Yonos PICO 25/1-5 1~23 V - Rp 1,5 1, 1,5 2, 2,5 3, Pump curves H/m
More informationData sheet: Wilo-Stratos PICO 25/
Data sheet: Wilo-Stratos PICO 25/1-4-13 Pump curves Δp-c (constant) 1 2 p-c v 3 4 5 Rp ½,4,8 1,2 1,6 Rp 1m/s,2,4,6,8 1, 1,2 Rp 1¼ H/m 4, Wilo-Stratos PICO 15/1-4, 25/1-4, 3/1-4 1~23 V - Rp ½, Rp 1, Rp
More informationSCX-DCX SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air conditioning Light commercial range 2 Pole - 50 Hz 230 V OPERATING LIMITS
V OPERATING LIMITS Flow up to : m /h Heads up to:, m Max. operating pressure: bar Temperature range : to + C* Max. temperature ambient: + C ND of ports : and * except CXL : - to + C Replace CXL SCX-DCX
More informationData sheet: Wilo-CronoLine-IL 65/160-5,5/2
Data sheet: Wilo-CronoLine-IL 65/16-5,5/2 Pump curves 2-pole, 5 Hz H[m] 45 4 35S 3 25 2 15 1 5 P 2 [kw] 12 2 4 6 8 1 Q[m³/h] 8 4 Qmin IL 65/16-5,5/2 IL 65/17-11/2 IL 65/15-5,5/2 Wilo-CronoLine-IL 65/17
More informationData sheet: Wilo-CronoLine-IL 65/130-4/2
Data sheet: Wilo-CronoLine-IL 65/13-4/2 Pump curves 2-pole, 5 Hz H[m] 32 28 24 I 2 I 16 12 8 4 2 4 6 8 1 5 1 15 2 25 3 Q[l/s] P 2 [kw] Ø 14 6 Ø 127 4L Ø 117 2 Ø 18 2 4 6 8 1 η p[%] Qmin IL 65/14-5,5/2
More informationData sheet: Wilo-CronoLine-IL 50/120-2,2/2
Data sheet: Wilo-CronoLine-IL 5/12-2,2/2 Pump curves 2-pole, 5 Hz H[m] 28 24 2 Qmin IL 5/14-3/2 IL 5/13-3/2 Wilo-CronoLine-IL 5/14 - Wilo-CronoLine-IL 5/11 IL 5/14-4/2 Approved fluids (other fluids on
More informationData sheet: Wilo-CronoLine-IL 80/145-1,1/4
Data sheet: Wilo-CronoLine-IL 8/145-1,1/4 Pump curves 4-pole, 5 Hz H[m] 12 1 8 6 4 2 2 4 6 8 1 5 1 15 2 25 3 P 2 [kw] 2, 1,5 Ø 156 1, Ø 144,5 Ø 133 2 4 6 8 1 η p[%] Qmin IL 8/17-2,2/4 IL 8/16-1,5/4 IL
More informationData sheet: Wilo-CronoLine-IL 50/200-1,5/4
Data sheet: Wilo-CronoLine-IL 5/2-1,5/4 Pump curves 4-pole, 5 Hz H[m] 18 16 14 12 1 8 6 4 2 1 2 3 4 5 4 8 12 Q[l/s] P 2 [kw] Ø 28 1,5 Ø 197 1,,5 1 2 3 4 5 η p[%] Qmin Wilo-CronoLine-IL 5/22 - Wilo-CronoLine-IL
More informationData sheet: Wilo-Yonos MAXO 40/0,5-16
Data sheet: /,5- Pump curves v 5 5 5 6 P /W n= const 5 5 /,5- ~ V - DN /,5- ~ V - DN 6 m/s Approved fluids (other fluids on request) Heating water (in accordance with VDI 5) Water-glycol mixtures (max.
More informationFAC, FAD, FAT, FAG, FAH, FACV, FADV, FATV SIGMA PUMPY HRANICE THREE-SCREW PUMPS
SIGMA PUMPY HRANICE FAC, FAD, FAT, FAG, FAH, FACV, THREE-SCREW PUMPS SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz
More informationInline Pumps. Product review. Wilo-VeroLine-IPL. Single-head pumps: Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump
Product review North America Duty charts 7 RPM - Hz - North America 9 IPL. 7 IPL IPL. IPL IPL. RPM - Hz - North America IPL. IPL IPL. IPL Single-head pumps: Single stage inline, flanged, long coupled,
More informationCALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA
Solar pump stations 78 and 79 series 0/4 N CLEFFI 04/ N CCREDITED ISO 900 FM 4 ISO 900 No. 000 Function Solar pump stations are used on the primary circuit of solar thermal water heating systems to control
More information3 Specification Magneta Smedegaard
3 Specification Magneta Smedegaard 3.1 Variable Speed Circulator Pumps Main applications Heating, ventilation, air-conditioning, refrigerating and circulation systems - One-pipe and two-pipe systems -
More informationSeries description: Wilo-TOP-STGD
ATAC Solutions 1622 8824 / Series description: Wilo-TOP-STGD Wilo-TOP-STGD 15 4/ 1 5 Design Glandless double circulation pump with flange connection. Application Primary circuits of solar and geothermal
More informationData sheet: Wilo-CronoLine-IL 40/220-1,5/4
Data sheet: Wilo-CronoLine-IL 4/22-1,5/4 Pump curves 4-pole, 5 Hz H[m] 2 18 16 14 12 1 8 6 4 2 P 2 [kw] 5 1 15 2 25 1 2 3 4 5 6 7 8 1,2 Ø 22,8,4 5 1 15 2 25 η p[%] 6 4 2 Qmin 5 1 15 2 25 Dimension drawing
More informationGRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz
GRUNDFOS DATA BOOKLET Grundfos UPBasic Circulator pumps 50 Hz Contents General data Performance ranges Page Product range, 1 x 0 V, 50 Hz Page 4 Type key Page 4 Construction Page 4 Material specification
More informationreal quality made in italy circulation pumps
GB real quality made in italy circulation pumps real quality made in italy E N E R G Y S A V I N G P U M P S PUMPING TECHNOLOGY Due to the diversity of nominal diameters, body lengths and speeds our extremely
More informationRUJA AUTOMATION June User manual. D R PP Filter - Unit. Page 1 of 10 User manual D-R--P-Filter -Unit
User manual D R PP Filter - Unit Page 1 of 10 User manual D-R--P-Filter -Unit 1. Technical specifications 2. Safety instructions 3. User section 4. Spare parts list 5. Ordering info Page 2 of 10 User manual
More informationCIRCULATION PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS VORTEX HEATING PUMPS
VORTEX HEATING PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS 90 C 80 C 70 C 60 C 50 C 40 C 30 C 20 C Pumps Technical structure Technical data Fitting kits Replacement overview 2 TECHNICAL STRUCTURE
More informationGrundfos Home Booster
GRUNDFOS DATA BOOKLET Grundfos Home Booster UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 5/6 Hz Grundfos Home Booster Table of contents 1. Product description 3 Applications..................................................................................
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationLiquid ring vacuum pumps
Liquid ring vacuum pumps LEH 350, LEH 450 Pressure range: Suction volume flow: 33 to 1013 mbar 120 to 535 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More informationData sheet: Wilo-CronoLine-IL 125/210-5,5/4
Data sheet: Wilo-CronoLine-IL 15/1-5,5/ Pump curves -pole, 5 Hz H[m] 18 16 1 1 1 8 6 P [kw] 8 1 16 6 Qmin IL 15/-5,5/ IL 15/1-5,5/ IL 15/19-/ Wilo-CronoLine-IL 15/ - Wilo-CronoLine-IL 15/19 IL 15/-7,5/
More informationFCX TECHNICAL BOOKLET
FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.
More information40 geothermal ground loop manifolds
40 geothermal ground loop manifolds GeoCal (key features listed left) This is the first thermoplastic, fully modular manifold system designed specifically for installations using ground source heat pumps.
More informationDIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC VALVES
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 05 23 PART 1 GENERAL 1.01 DESCRIPTION A. Provide valves for the following systems: 1. Heating Hot Water 2. Chilled Water 3. Condenser
More informationPressure boosting Single pumps
Series description Wilo-Economy MHI Design Non-self-priming multistage pump Application Water supply and Commerce and industry Cooling water circulation systems Washing and sprinkling systems Type key
More information2-port ball valves with flanged connection, PN25
s 4 120 ACVATIX 2-port ball valves with flanged connection, PN25 VAF51.. Gray cast iron EN-GJL-250 (HT250) valve body DN 65...150 k vs 63...360 m 3 /h Angle of rotation 90 Flange connection to ISO 7005-2
More informationUNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data
Submittal Data PROJECT: REPRESENTATIVE: ENGINEER: CONTRACTOR: UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP 15-18 B5 Circulator pumps QUANTITY: DATE: DATE: DATE: Product photo could
More informationCEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw
CEB 71204/a of 13 december 2005 SLSHR 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw C.E.B. SLSHR RANGE TECHNICAL CATALOGUE 05/12/13 CONTENTS CONTENTS 2 APPLICATIONS
More informationACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB
ACG7 Std Line Product Description Flow volume: 80-1200 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The Std Line (standard)
More information2-port seat valves PN25 with flanged connection
4 373 Acvatix 2-port seat valves PN25 with flanged connection VVF52.. Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m 3 /h Can be equipped with SAX..-electromotoric or SKD..- or
More information4 Specification Magneta Smedegaard twin pumps
4 Specification Magneta Smedegaard twin pumps 4.1 Variable Speed Circulator Pumps Designation: Example Magneta Smedegaard 30-60D Key to the designation Main applications Heating, ventilation, air-conditioning,
More informationFilter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN
More informationData sheet: Wilo-CronoLine-IL 100/250-5,5/4
Data sheet: Wilo-CronoLine-IL 1/25-5,5/ Pump curves -pole, 5 Hz H[m] 2 2 16 Qmin IL 1/25-5,5/ IL 1/26-7,5/ Wilo-CronoLine-IL 1/27 - Wilo-CronoLine-IL 1/25 IL 1/27-11/ IL 1/26-11/ Approved fluids (other
More informationAccessories. UP timer. Timer control. Approvals. UP Series
UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:
More informationModel and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS
Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact
More informationSTAF-SG. ANSI flanges. Balancing valves Size 3/4-16
STAF-SG ANSI flanges Balancing valves Size 3/4-16 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationSeated valves VF 2, VL 2-2-way VF 3, VL 3-3-way
Data sheet Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way Description The valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol
More informationHigh-pressure pumps Series HP49
High-pressure pumps Series HP49 www.andritz.com/pumps General Description / Application Multi-stage high pressure pumps for water supply, irrigation and industrial applications, for hot and cold water
More informationElectronic Control Valves
MODEL 131 Series (Full Internal Port) 631 Series (Reduced Internal Port) Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function
More informationACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB
ACF5 Std Line Product Description Flow volume: 310-2900 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The ACF pumps are used
More informationHERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...
Datasheet 1 45XX XX, Issue 0216 Table of contents General information about pump groups...2 Direct (1 4510 XX)...4 DN 20 DN 25 DN 32 Mix (1 4511 XX)...6 DN 20 DN 25 DN 32 Mix with bypass (1 4511 XX)...10
More informationUse Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.
V5W Lubricator Automatic Continuous Operation The V5W Lubricator consists of a motor-driven gear pump, with a controlled bypass valve. (constant volume or constant pressure models) The fully automatic
More informationCirculators for heating and air-conditioning
Circulators for heating and air-conditioning Can you think of a range of pumps offering you more in precision and convenience for your various projects? H kpa 600 Standardized circulators 200 100 Inline
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.
More informationHigh pressure centrifugal pumps
Series description H[ft] 5 5 4 8 Wilo-Multivert-MVIS 6 Hz - North America Q[m³/h] H[m] 5 4 MVIS 5 MVIS MVIS 5 5 4 6Q[US g.p.m.] 8 6 Pump series Wilo-Multivert MVIS 5..,.., 5.. Design Non-self priming multistage
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES
BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationM Series Condensate Recovery Unit
0898050/3 IM-P089-29 ST Issue 3 M Series Condensate Recovery Unit Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Wiring diagram
More informationLenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.
Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Circulator Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications
28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications
More informationApplication & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump
Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November
More informationData sheet: Wilo-CronoTwin-DL 65/250-4/4
Data sheet: Wilo-CronoTwin-DL 65/25-/ Pump curves -pole - individual operation H[m] 2 2 2 Qmin DL 65/25-3/ Wilo-CronoTwin-DL 65/27 - Wilo-CronoTwin-DL 65/25 DL 65/25-/ DL 65/27-5,5/ Approved fluids (other
More information4-Way Mixing Panel Submittal - Page 1 of 6
Submittal - Page 1 of 6 Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Heat Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description
More informationT200 Pressure Regulator
T200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges T202 has internal relief valve for overpressure protection The T200 series pressure regulator is a manual, direct acting,
More informationTHRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES
THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES TQ/TV THRU-DRIVE HYDRAULIC VANE PUMPS TQ/TV SERIES Thru-drive pumps save installation space and cost by eliminating double shaft extension electric motors or
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.
More informationData sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)
Data sheet: Wilo-TOP-Z 3/1 (1~23 V, PN 1, RG) Pump curves Single-phase current H/m 9 8 v,5 1 1,5 2 2,5 3 m/s Wilo-TOP-Z 3/1 1~23V - Rp 1¼ Approved fluids (other fluids on request) Drinking water and water
More informationSIL Inline Single Stage Centrifugal Pumps
SIL Inline Single Stage Centrifugal Pumps SIL Inline Pump Range True Reliability Sulzer s new inline pump range (SIL) has been designed to fulfill efficiency regulations across all industries and also
More informationGRUNDFOS DATA BOOKLET NS, PF. 50 Hz
GRUNDFOS DATA BOOKLET 50 Hz Table of contents 1. PF 3 General description 3 Features 3 Constructional features 3 Material specification 3 Marks 3 Technical data 4 Performance curves 4 Dimensions 5 Product
More informationSeries: CT. 4CT RPM - 60Hz. CT RPM - 60Hz. (See Indivdual curves for symbol number)
4CT - 25-60Hz. CT - 450-60Hz. (See Indivdual curves for symbol number) Symbol 2 4 5 6 8 9 0 *MAXIMUM HEAD HP /2 /4 / /2 /4 / /2 /4 /4 /2 /4 Catalog - Phase - Phase 5CTM CTM CT6M 5CT6M CT6M CT5M 5CT5M 24CTM
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.
More informationUNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data
Submittal Data PROJECT: REPRESENTATIVE: ENGINEER: CONTRACTOR: UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA3 4-8 F N QUANTITY: Full range of intelligent, high-efficiency circulators
More informationPowers TM Controls SW 141 Differential Static Airflow Switches
Powers TM Controls SW 141 Differential Static Airflow Switches Document No. 155-052P25 SW 1 0518 Description The SW 141 Airflow Switch senses static differential pressure and the diaphragm operated snap
More informationHydraulic gear pumps and motors
PL 01 T E DISPLACEMENTS From To Hydraulic gear pumps and motors 0.07 in 3 /rev (1.07 cm 3 /rev) 5.56 in 3 /rev (91.10 cm 3 /rev) through bore aluminum body PRESSURE Max. Continuous Max. Intermittent Max.
More informationOff-line filter / cooler unit BKF
FluidControl Off-line filter / cooler unit BKF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated
More informationData sheet: Wilo-Stratos-Z 25/1-8
Data sheet: Wilo-Stratos-Z 25/1-8 Pump curves 7 337 1 /min - 9 V 6 34 1 /min - 8 V 5 271 4 1 /min - 7 V 239 1 /min - 6 V 3 26 1 /min - 5 V 2 173 1 /min - 4 V 14 1 1 /min - 3 V 2 4 6 8,5 1, 1,5 2, 2,5 Q/l/s
More information2-Port Seat Valves with Flange, PN 25
4 7 2-Port Seat Valves with Flange, PN 25 VVF52... Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m /h Can be equipped with SQX- electromotoric or SKD...- or SKB...- electrohydraulic
More informationSCX-DCX - SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air-conditioning Light commercial range 50 Hz OPERATING LIMITS APPLICATIONS ADVANTAGES
V OPERATING LIMITS Flow rates up to: m /h Heads up to:. m Max. operating pressure: bar Temperature range: to + C* Max. temperature ambient: + C DN of ports: and * except CXL : - to + C 9, H m SCX-DCX SXM-DXM
More information2-Port Seat Valves with Flange, PN 25
OEM 2-Port Seat Valves with Flange, PN 25 VVF52...E Spheroidal cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.63 25 m 3 /h Can be equipped with SQX E- motoric or SKD E- or SKB - electrohydraulic
More informationRichter Sampling Valves
Richter Sampling Valves PA/F, PA/S Body ductile iron with PFA lining or investment cast stainless steel Bellows-sealed Safety packing gland Representative sampling Richter sampling valves Fields of application
More informationOVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps
OVIM/OVIMF A New Vision for Quality Pumps OVIM 60Hz OVIMF 60Hz Light Vertical Multistage Centrifugal Pumps PERFORMANCE SCOPE OVIM/OVIMF PRODUCT RANGE OVIM OVIM2 OVIM3 OVIM4 OVIM8 OVIM6 OVIM32 OVIM42 OVIM65
More informationSubmit Manufacturer certification and test reports. Submit Detail drawing brochure catalogue. Submit Manufacturer certification and test reports
AL Qubbe water ProjectCompliance Sheet The following Technical data shall be furnished and filledby the bidders: Mechanical works Item1 LowLeft Submersible pumps 5 Type Grundfos, Wilo, flyght Sweden. 6
More informationRichter Sampling Valves
Richter Sampling Valves PA/F, PA/S Body ductile iron with PFA lining or investment cast stainless steel Bellows-sealed Safety packing gland Representative sampling Richter sampling valves Fields of application
More informationLPE4. OptiLine. Product Description. Max differential pressure: 16 bar LPE GB
LPE4 OptiLine Product Description Flow volume: 8-175 l/min Max differential pressure: 16 bar Applications: Circulation and transfer 1. Applications 1.1 Functionality The LPE OptiLine pump is used for a
More informationCentrifugal pumps. Main catalogue.
Main catalogue 1 6667 EN Centrifugal pumps for machine tools and filter systems, printing and packaging machines, temperature control units Quality Management DIN EN ISO 9001:08 www.spandaupumpen.com Environmental
More informationDESCRIPTION 9.4 G 3/4"M
DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS
More informationData sheet: Wilo-VeroLine-IPL 100/ /4
Data sheet: Wilo-VeroLine-IPL 1/145-1.5/4 Pump curves 4-pole, 5 Hz H[m] Qmin 1 8 Wilo-VeroLine-IPL 1/175 - Wilo-VeroLine-IPL 1/135 Approved fluids (other fluids on request) Heating water (in accordance
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components
7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic
More informationOVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps
OVIM/OVIMF A New Vision for Quality Pumps OVIM 60Hz OVIMF 60Hz Light Vertical Multistage Centrifugal Pumps OVIM/OVIMF 60Hz General Data PERFORMANCE SCOPE OVIM/OVIMF OVIM1 OVIM2 OVIM3 OVIM4 OVIM8 OVIM16
More informationData sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)
Data sheet: Wilo-TOP-Z 3/7 (3~4 V, PN 1, RG) Pump curves Three-phase current H/m 5 4 v,5 1 1,5 2 2,5 Wilo-TOP-Z 3/7 3~4 V - Rp 1¼ m/s Approved fluids (other fluids on request) Drinking water and water
More informationData sheet: Wilo-VeroLine-IPL 65/ /2
Data sheet: Wilo-VeroLine-IPL 65/145-5.5/2 Pump curves 2-pole, 5 Hz H[m] 3 25 15 5 Qmin IPL 65/155-5,5/2 Wilo-VeroLine-IPL 65/155 - Wilo-VeroLine-IPL 65/145 IPL 65/145-5,5/2 IPL65/155-7,5/2 5 3 4 5 6 7
More informationLiquid ring vacuum pumps with magnetic coupling
Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum
More information2-Way & 3-Way Non Spring Return Characterized Ball Valves
VCB30 Series Revision Date June 6, 2014 2-Way & 3-Way Non Spring Return Characterized Ball Valves General The VCB30 Series electric rotary-motion actuatordriven characterized ball valves are designed specifically
More informationRichter Sampling Valves
Richter Sampling Valves PA/F, PA/S Body ductile iron with PFA lining or investment cast stainless steel Bellows-sealed Safety packing gland Representative sampling Richter sampling valves Fields of application
More informationSBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual
SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from
More information