1 Solar pump stations 78 and 79 series 0/4 N CLEFFI 04/ N CCREDITED ISO 900 FM 4 ISO 900 No. 000 Function Solar pump stations are used on the primary circuit of solar thermal water heating systems to control the temperature of the hot water storage. The pump inside the unit is activated by the signal from a differential temperature controer. The unit contains the functional and safety devices for optimum circuit control. They are available with both supply and return connection or with return connection only. The isolar PLUS temperature differential controer, code 70 (optional), is suitable for management and control of 0 preconfigured solar thermal system arrangements instaed in an optional insulation jacket (code 7) that mounts to the top of the pump station for a nice clean assembly and simplified wiring. Product range Solar pump stations are pre-assembled and leak-tested. Components include three-speed pump with wide flow rate range, safety relief valve, ba valves with built-in flow checks in return (and supply/flow for dual-line models, not available in drainback model), temperature gauges in return (and supply/flow for dual-line models), pressure gauge, manual air vent (dual-line models only), expansion tank connection, connections for flushing and fiing, and foam insulation. 787 Single-line solar pump station with speed pump, return connection and flow meter scale to 8 gpm...connection /4 female 787 Single-line solar pump station without pump, return connection and flow meter scale to 8 gpm...connection /4 female 790 Dual-line solar pump station with speed pump, supply and return connections, flow meter scale to 8 gpm...connections /4 female 790 Dual-line solar pump station without pump, supply and return connections, flow meter scale to 8 gpm...connections /4 female 789 Single-line solar pump station for drainback with speed pump, return connection and flow meter scale to 8 gpm...connections /4 female Technical specifications Materials Shut-off valve body: Check valve: Temperature gauge: ir Separator Instrument holder fitting Sealing gaskets: O-Ring seal elements: Flow meter Transparent level gauge: Flow indicator: Hydraulic seals: steel/aluminum EPDM EPDM PS EPDM Insulation Material: PP verage thickness: /4 inch ( mm) Density:.8 lb/ft³ (4 kg/m ) Working temperature range: - 0 F (- C) Thermal conductivity: 0. BTU in/hr ft² F 0.07 W/(m K) at 0 F (0 C) Reaction to fire (UL94): class HBF Performance Suitable fluids: water, glycol solution Max. percentage of glycol: 0% Maximum working temperature: air separator side supply: F ( C) pump side return: 0 F (0 C) Max. working pressure: 4 psi (0 bar) Safety relief valve working temperature range: - to F (-0 C) Safety relief valve setting: 90 psi ( bar) Check valve min. opening pressure (Dp): /4 psi ( kpa) Shut-off and check valves working temperature range: - to F (-0 C) Flow meter working temperature range: to 0 F (-0 0 C) Flow rate adjustment range: to 8 gpm Flow rate indicator accuracy: ±0% Pressure gauge scale: 0 to 4 psi (0 0 bar) Temperature gauge scale: to F (0 C) Connections: /4 female straight thread Fitting adapters, purchase separately: ½", ¾", " male straight thread for SolarFlex and sweat connections Hose connection: /4 Fi/drain connections: with hose connection 9/" OD ( mm)
2 Pump Model Wilo Star S- Three-speed pump: Wilo Star SU--0 cast iron Electric supply: V 0 Hz Max. pressure: psi (0 bar) Max. liquid temperature: 0 F (0 C) Min. liquid temperature: 4 F (-0 C) Max. current: 0.97 Max. power consumption: 0 W Protection class: CS enclosure gency approval: culus Flow range: 0 to 8 gpm (0 to. l/s) Head range: 0 to ft (0 to.4 m) H [ft] [m /h] 7 4 H [m] H [ft] 9 9 Pump Model Grundfos Solar - Drainback Three-speed pump: Grundfos Solar -U 0 cast iron Electric supply: V 0 Hz Max. pressure: psi (0 bar) Max. liquid temperature: 0 F (0 C) Min. liquid temperature: 4 F (-0 C) Max. current: 0.9 Max. power consumption: 7 W gency approval: UL 778, CS./08 per Intertek Flow range: 0 to 8.4 gpm (0 to 0. l/s) Head range: 0 to ft (0 to.0 m) PPLICTION S NOTE: Pump data per Manufacturer technical specifications. Dimensions B B C D C F D Q [US gpm] [gpm] E E (no pump) ¾" B ¼" C " D ¾" E 8" 799 Weight 4 lb (.4 kg) 0 lb (4. kg) 4 lb (.4 kg) 790 ¾" B 4" C ¼" D " E 8" F ¾" 790 (no pump) Weight 7 lb (7.7 kg) lb (. kg)
3 Characteristic components ) Circulation pump ) Safety relief valve ) Fi/drain valve with controever 4) Instrument holder fitting with pressure gauge ) Flow meter ) ir separator with air vent and shut-off valve with check valve 7) Supply (flow) temperature gauge 8) Return temperature gauge 9) Pre-formed she insulation 0) Shut-off ba valve with check valve and temperature gauge holder knob (Drainback station does not have a check valve) ) Connection kit for expansion tank (purchase separately) ) Hose connection ) Mounting bracket 4) Manual air vent release screw head ) 9 mm hex wrench for shut-off ba valve and flow meter valve Connection adapter fittings are purchased separately, see page Dual Single
4 Shut-off and check valves The shut-off valves are equipped with a built-in check valve, positioned inside the ba.. To aow the passage of the medium in both directions, the ba valves must be opened to 4 using a 9 mm hex wrench (supplied with unit). Temperature gauge can be removed if needed better view this operation. The check valve is opened by the ba, see figure (). Flow meter The flow meter is a flow rate measuring device, float equipped, with an adjustment ba valve. The meter has a range of to 8 gpm. The flow meter must always be instaed in a vertical position. Captive nut Flow rate adjustment. In normal system operation, the ba valves must be fuy open. 0 F /4 fitting C 0 Thermometric label Graduation /4 fitting thermometric label on the back of the flow meter signals if the maximum permitted temperature (0 F/0 C) has been exceeded: white = temperature not exceeded; dark = maximum temperature exceeded. Warranty wi be void if this label is removed. Correct position ir separator Incorrect position The solar pump stations with supply and return connections (79 series) are equipped with an air separator on the supply line. The gases separated from the heat transfer medium coect at the top of the air separator. The coected gases must be evacuated from time to time (every day after putting into operation and afterwards, depending on the quantity of air, once a week or once a month) by opening the manual air vent with a suitably sized screwdriver. To maintain optimal efficiency of the solar thermal system, afterwards, it is necessary to discharge air from the system every six months using the air separator. The reading is taken from the top edge of the float Correction for different density liquids Changes in flow rate readings remain within the indicated accuracy (±0%) for glycol percentages of up to 0%. Complete closing and opening of the valve The valve can be fuy closed or fuy open. slot on the valve adjusting stem indicates the status of the valve. 8 7 Fuy closed Important! Use only a 9mm hex wrench (supplied with unit) to adjust the flow meter. open closed Fuy open B
5 Pump station fittings Kits designed for connecting 78 and 79 pump stations to SolarFlex stainless steel piping with EPDM insulation to complete solar water heating system instaations. ½" SolarFlex connection directly to top or bottom ¾" female thread* connection. Kits designed for connecting 78 and 79 pump stations to copper piping with sweat connections to complete solar water heating system instaations. ½" sweat fittings to top or bottom ¾" female thread* connection. N ¾" male thread x ¾" male thread N49 ¾" male thread x ½" sweat fitting ½" SolarFlex connection directly to top and bottom ¾" female thread* connection. 4 each. ½" sweat fittings to top and bottom ¾" female thread* connection. 4 each. N7 ¾" male thread x ¾" male thread N749 ¾" male thread x ½" sweat fitting ¾" SolarFlex connection directly to top or bottom ¾" female thread* connection. ¾" sweat fittings to top or bottom ¾" female thread* connection. N0 ¾" male thread x " male thread ¾" SolarFlex connection directly to top and bottom ¾" female thread* connection. 4 each. N9 ¾" male thread x ¾" sweat fitting ¾" sweat fittings to top and bottom ¾" female thread* connection. 4 each. N70 ¾" male thread x " male thread " SolarFlex connection directly to top or bottom ¾" female thread* connection. N79 ¾" male thread x ¾" sweat fitting " sweat fittings to top or bottom ¾" female thread* connection. N0 ¾" male thread x ¼" male thread " SolarFlex connection directly to top and bottom ¾" female thread* connection. 4 each. N9 ¾" male thread x " sweat fitting " sweat fittings to top and bottom ¾" female thread* connection. 4 each. N70 ¾" male thread x ¼" male thread N79 ¾" male thread x " sweat fitting *a threads referenced on this page are straight (metric) threads.
6 Replacement Pumps Replacement pumps fits current solar pump stations 78 & 79. speed V " male union thread. gency approval: culus. Replacement pump fits current drainback station, code 789. speed V " male union thread. gency approval: UL778, CS./08. N70 N8 Wilo Star S-, head / 8 gpm Wilo Star S-, head / 8 gpm N7 Grundfos Solar - Drainback, ' head / 8.4 gpm pplication diagrams Shut-off valve Pump Shut-off valve ir vent Pump Expansion tank ir vent Temperature gauge Expansion tank Safety valve Temperature gauge Safety valve utomatic fiing
7 Replacement temperature gauges Temperature gauges fit 78 & 79 solar stations. Scale: to F (0 to C). F979 F978 ½" red dial temperature gauge ½" blue dial temperature gauge SPECIFICTION SUMMRY 78 series Solar Pump Station: Single-line solar pump station for pressured closed-loop systems with or without pump. Connections ¾ inch female straight thread. Brass body. Steel and aluminum temperature gauges in return connection. EPDM seals, O-Rings and gaskets, asbestos free. PP insulating she, thermal conductivity 0. BTU in/hr ft² F 0.07 W/(m K) at 0 F (0 C). Ba valves with built-in flow checks in return line. Expansion tank connection ½ inch male straight thread. Fiilng/drain hose connections ¾ inch male hose thread. Suitable fluids: water or 0 percent maximum glycol solution. Maximum working temperature 0 degrees F (7 degrees C). Maximum working pressure 4 psi (0 bar). Safety relief valve temperature range minus to degrees F (minus 0 to degrees C). Safety relief valve factory set at 90 psi ( bar). Minimum opening shut-off and check valve differential pressure ¼ psi ( kpa). Flow meter scale to 8 gpm. Maximum return flow meter temperature degrees F (0 degrees C). Pressure gauge scale 0 to 4 psi (0 to 0 bar). Temperature gauge scale to degrees F (0 to degrees C). 787 station without pump. 787 includes Wilo Solar Star S- speed pump. Cast iron body. Power supply V - 0 Hz. Maximum pressure psi (0 bar). Maximum temperature 0 degrees F (0 degrees C). gency approval: culus. Provide with SolarFlex adapter or sweat fittings for top and bottom return connections, ½ inch, ¾ inch or inch. 79 series Solar Pump Station: Dual-line solar pump station for pressured closed-loop systems with or without pump. Connections ¾ inch female straight thread. Brass body. Steel and aluminum temperature gauges in return and flow (supply) connections. EPDM seals, O-Rings and gaskets, asbestos free. PP insulating she, thermal conductivity 0. BTU in/hr ft² F 0.07 W/(m K) at 0 F (0 C). Ba valves with built-in flow checks in return and flow (supply) lines. Expansion tank connection ½ inch male straight thread. Fiilng/ drain hose connections ¾ inch male hose thread. Suitable fluids: water or 0 percent maximum glycol solution. Maximum working temperature 0 degrees F (7 degrees C). Maximum working pressure 4 psi (0 bar). Safety relief valve temperature range minus to degrees F (minus 0 to degrees C). Safety relief valve factory set at 90 psi ( bar). Minimum opening shut-off and check valve differential pressure ¼ psi ( kpa). Flow meter scale to 8 gpm. Maximum return flow meter temperature degrees F (0 degrees C). Pressure gauge scale 0 to 4 psi (0 to 0 bar). Temperature gauge scale to degrees F (0 to degrees C). 790 station without pump includes Wilo Solar Star S- speed pump. Cast iron body. Power supply V - 0 Hz. Maximum pressure psi (0 bar). Maximum temperature 0 degrees F (0 degrees C). gency approval: culus. Provide with SolarFlex adapter or sweat fittings for top and bottom flow (supply) and return connections, ½ inch, ¾ inch or inch. 789 drainback pump station Solar Pump Station: Single-line solar pump station for drainback systems with pump. Connections ¾ inch female straight thread. Brass body. Steel and aluminum temperature gauges in return connection. EPDM seals, O-Rings and gaskets, asbestos free. PP insulating she, thermal conductivity 0. BTU in/hr ft² F 0.07 W/(m K) at 0 F (0 C). Ba valves with built-in flow checks in return line. Expansion tank connection ½ inch male straight thread. Fiilng/drain hose connections ¾ inch male hose thread. Suitable fluids: water or 0 percent maximum glycol solution. Maximum working temperature 0 degrees F (7 degrees C). Maximum working pressure 4 psi (0 bar). Safety relief valve temperature range minus to degrees F (minus 0 to degrees C). Safety relief valve factory set at 90 psi ( bar). Minimum opening shut-off and check valve differential pressure ¼ psi ( kpa). Flow meter scale to 8 gpm. Maximum return flow meter temperature degrees F (0 degrees C). Includes Grundfos Solar -U pump. Cast iron body. Power supply V - 0 Hz. Maximum pressure psi (0 bar). Maximum temperature 0 degrees F (0 degrees C). gency approval: UL standard 778 and CS standard C. No. 08 certified by Intertek. Provide with SolarFlex adapter fittings for top and bottom return connections, ½ inch, ¾ inch or inch.. We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice. Caleffi North merica, Inc. 88 W. Milwaukee Road Milwaukee, WI 8 Tel: Fax: sales@caleffi.com Copyright Caleffi North merica, Inc.
INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications
28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components
7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic
More informationCALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function
HydroMixer direct distribution unit for heating systems 6 series REDITED LEI ISO 900 M 6 ISO 900 No. 000 07/ N unction The 6 series HydroMixer TM provides high temperature flow direct to secondary heating
More informationCALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function
Hydroixer motorized temperature mixing unit 67 series CCREDITED CLEI 09/ N ISO 900 6 ISO 900 No. 000 unction The 67 series Hydroixer provides a modulating three-point floating type non-spring return motorized
More informationCALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA
ifferential pressure by-pass valve RIT LFFI series / N ISO FM ISO No. Replaces / N Function The differential pressure by-pass valve is used in systems with a fixed speed circulating pump supplying several
More informationCALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB
Motorised temperature regulating unit for heating and air conditioning systems 67...WYP - 67...UPM series CCREDITED ISO 9 FM 65 CLEFFI 5/7 G replaces dp 5/ G Function The motorised temperature regulating
More informationTHERMOSETTER Recirculation thermal balancing valve
THERMOSETTER Recirculation thermal balancing valve 116 series 01325/17 NA ACCREDITED Function ISO 9001 FM 21654 The THERMOSETTER adjustable thermal balancing valve is used for automatic balancing of recirculation
More informationCALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function
Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating
More informationCALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function
Direct supply unit for heating systems 65 series ACCREDITED ISO 9 FM 65 CALEFFI 7/7 GB replaces dp 7/5 GB Function The direct supply unit performs the function of supplying the heating system circuits
More informationCALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range
iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected
More informationTHERMOSTATIC CONTROL HEADS:
Thermostatic radiator valves for towel warmer style radiators 338 33, 00 series REDITED LEFFI 0009/3 N ISO 900 FM 6 ISO 900 No. 0003 Function onvertible radiator valves are typically used in North merica
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More information132 Series. QuickSetter Balancing Valve with flow meter NA Function
NA800 www.caleffi.com QuickSetter Balancing Valve with flow meter Copyright 0 Caleffi Series Function The QuickSetter+ balancing valve accurately controls the flow rate in plumbing systems. Proper system
More informationACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM
alancing valve with flow meter 1 series REDITED ISO 9001 FM 1 LEFFI 0119/1 G replaces dp 0119/08 G Function The balancing valve is a hydraulic device that accurately regulates the flow rate of heating
More informationCALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip
CALEFFI www.caleffi.com 80.0 QuickSetter Balancing Valve with flow meter Copyright 08 Caleffi Series Function The balancing valve accurately controls the flow rate of heating and cooling transfer fluid
More information548 hydraulic separator
hydraulic separator 120 C 120 105 C 105 120 Serie 548 120 C 105 C 105 548 imensions C B Function The ltecnic 548 hydraulic separator combines several different components, each of which performs a specific
More informationOne system. One company.
One system. One company. The prepackaged, specially engineered solar water heating system includes all of the components needed for a standard installation from the solar collectors, to the pump station
More informationCALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)
Ball shut-off valve fitted for integrated flow rate measuring sensor series ACCREDITED CALEFFI 034/3 GB ISO 900 FM 654 ISO 900 No. 0003 Function The valve allows to shut the circuit off and is fitted for
More informationCALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51
Pressure independent control valve (PICV) 145 series CCREDITED CLEFFI 012/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The pressure independent control valve is a device composed of an automatic
More informationCALEFFI. zone valves. Z series 01115/14 NA. Replaces 01115/11 NA. Function
Z series zone valves Function REGI STERE S EN ISO 900:000 ert. n FM 64 UNI LEFFI 0/4 N Replaces 0/ N Z-one valves are used to automatically shut-off the flow or redirect hot and chilled water in hydronic
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB
Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB
Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute
More informationCALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.
Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationSafety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:
Balancing valve, fixed orifice 0 series CALEFFI 0/ NA ACCREDITED ISO 900 FM ISO 900 No. 000 Function Product range Caleffi 0 series low lead, manual balancing valves are used to measure and adjust the
More informationCALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function
FLOWCAL Automatic flow balancing valve with polymer cartridge 121 series REGISTERED BSI EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01141/11 NA Function The FlowCal automatic
More informationCALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.
Pre-assembled distribution manifold for radiant panel systems 668...S series ACCREDITED ISO 900 FM 65 ISO 900 No. 000 0/ GB Replaces 0/07 GB Function The distribution manifold for radiant panel systems
More informationR EGI S TERED. Function
Z series zone valves R EGI S TERE S EN ISO 900:000 ert. n FM 64 UNI EN ISO 900:000 ert. n 0003 LEFFI 0/09 N Replaces 0/04 N Function Z-one valves are used to automatically shut-off the flow or redirect
More informationCALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA
Motorized ball valves with -wire control 644-644 series SO 900 M 64 SO 900 No. 000 0/ N Replaces 0/07 N unction Zone valves are used to automatically shut-off the flow, redirect or modulate hot and chilled
More informationInstallation instruction
1 Safety Before installing the device, please read this manual carefully. Please note that the installation must be executed according to relevant technical rules. The installation must also be adapted
More informationPre-assembled distribution manifolds for radiant panel systems
Pre-assembled distribution manifolds for radiant panel systems Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating system circuits
More informationSOLAR HEATING SYSTEM
SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping
More informationSolar collector racking system CALEFFI NAS100 series ACCREDITED Function Product range NAS100 NAS100 NAS100 NAS100
Solar collector racking system NS100 series CCREITE ISO 9001 FM 21654 ISO 9001 No. 0003 CLEFFI 01281/14 N Replaces 01281/13 N The collectors must be mounted to two horizontal NS100 series four slot rails.
More informationSE M.C.N.51D
GRUNDFOS DATA BOOKLET SE1.110.200.200.4.52M.C.N.51D Grundfos pump 98179813 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/98179813/se1-110-200-200-4-52m-c-n-51d.html
More informationUNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data
Submittal Data PROJECT: REPRESENTATIVE: ENGINEER: CONTRACTOR: UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP 15-18 B5 Circulator pumps QUANTITY: DATE: DATE: DATE: Product photo could
More informationCALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB
Motorised ball valve for central heating systems 638 series M 21654 003 LI 01196/18 G replaces dp 01196/12 G unction Motorised ball valves allows both automatic shut-off and diversion of the thermal medium
More informationLowara Ecocirc Vario (EV)
Lowara Ecocirc Vario (EV) The speed of the pump can be manually regulated to meet the requirement of the system. The software enables a choice from infinite number of performance curves. Spherical Rotor/Stator
More informationProduct Information. Brass Manifolds. Version A
Product Information Brass Manifolds Version A Introduction Infloor offers a complete line of brass manifolds for radiant heating applications. This guide explains the how the manifolds work, the setup
More informationValves, controls + systems Valves and controls for solar installations Regusol-180
The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: The Oventrop programme for solar installations allows the connection of the collector to the storage cylinder within
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationSECTION VALVES PART 1 -GENERAL
SECTION 1571 0 VALVES PART 3- EXECUTION General Shut-off Valves Balancing Valves Drain Valves RELATED WORK Section 15430- Plumbing Specialties Section 15450- Plumbing Equipment PART 1 -GENERAL SCOPE This
More informationCALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB
ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for
More informationHERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs
HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15
More informationSECTION METERS AND GAUGES FOR HVAC PIPING
SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential
More informationCALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.
Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationZone Valves and Parts (Honeywell)
28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial
More informationSECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING
SECTION 22 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Valves, General 2. Gate Valves 3. Balancing Valves 4. Ball Valves 5. Swing Check Valves 6. Backflow Prevention Assemblies 7. Pressure
More informationGRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz
GRUNDFOS DATA BOOKLET Grundfos UPBasic Circulator pumps 50 Hz Contents General data Performance ranges Page Product range, 1 x 0 V, 50 Hz Page 4 Type key Page 4 Construction Page 4 Material specification
More informationInstallation, commissioning and servicing instructions
CALEFFI www.caleffi.com NA88156 GeoCal geothermal manifolds Installation, commissioning and servicing instructions 110 Series Function The GeoCal pre-assembled manifold for ground-source geothmal loops
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationDISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump
Description This preassembled pump group is part of the arberi trolli HEATING line. This distribution group allows the circulation of the thermal fluid, coming from the primary circuit and it maintains
More informationAccessories. UP timer. Timer control. Approvals. UP Series
UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:
More informationA-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories
Pneumatic Air Supply Manual 718 Filter Stations Section Product Bulletin Issue Date 0907 A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories Oil Removal and Pressure Reducing
More informationCast Iron Liquid Relief Valves
Cast Iron Liquid Relief Valves Features Bolted bonnet permits easy inspection and servicing without removal from system. Quality cast iron body and bonnet, insert and disc are available in either bronze
More informationComposite PEX-AL-PEX Tubing
04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192
More informationV46 Series Pressure-Actuated Water-Regulating Valves
FANs 1, 11 Product/Technical Bulletin V46 Issue Date 9 V46 Series Pressure-Actuated Water-Regulating Valves The V46 pressure-actuated modulating valves come in two types of control action: direct acting
More informationearth safe Fuel Systems for Critical Power
Fuel System Control Valves 100 Solenoid Valves 110 Solenoid Valve Slow Close 120 Actuated Ball Valves 123 Actuated Ball Valves 3-Way 130 Actuated Butterfly Valves 140 Fire Safety Fusible Link Valves 145
More informationIsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions
82 IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 83 Adjustment knob (sets supply temperature) Mixing Valve 1 Male BSP Threads Mixing Point Supply Inlet from Boiler Temperature Gauge (indicates
More informationB2 Series Characterized Control Valve, Non-Spring Return Actuator
2 Series Characterized Control Valve, Non-Spring ctuator Two-way Valve with Stainless Steel all and Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Maximum Differential: Pressure
More informationThis catalog contains the following geothermal accessory products and specification guides:
f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat
More informationCALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function
Manifolds in composite specifically designed for radiant panel systems 670 series cert. n 000 ISO 900 CALEFFI 06/05 GB Function Manifolds in composite are used to control and distribute the fluid in the
More informationCALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB
ydraulic separator-manifold SPO 559 series RT SO 01 M 21654 01084/16 replaces dp 01084/13 unction The SPO, a device which combines the functions of hydraulic separator and distribution manifold, is used
More informationSINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG
FUNCTION ICMA distribution manifolds are manufactured starting from a special profile of brass bar drawn into CW617-N. They can be divided into: Distribution manifolds with or without connection fittings
More informationA-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories
A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Installation Applications The A-4000 Series Oil Removal and Pressure-Reducing Stations (see Figure 1, Figure 2, Figure
More informationKunkle Models 91/218/228 liquid relief valves Safety and relief products
Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 228 Features Bolted bonnet allows easy inspection and servicing without removal from
More informationPIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5
PERFORMANCE SPECIFICATIONS PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5 PIC-V Valve 1. PRESSURE INDEPENDENT ACTUATED BALL VALVES AND CARTRIDGE (PIC-V)
More informationKunkle Models 91/218/228 liquid relief valves Safety and relief products
Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 8 Features Bolted bonnet allows easy inspection and servicing without removal from
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More informationGuide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY
SECTION 23 21 16 - HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Air
More informationInstallation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Tel.: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Commissioning Instructions High Temperature Zone
More informationP200 Pressure Regulator
P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,
More informationPage Concealed Flush Valve (1976 on)
8T _ Series Concealed Flush Valve (16 on) 2 10 14 11 15 1 8 OSC. HANDLE 16 1 10 14 1 12 15 8 4 1 /8" PUSH BUTTON 16 5/8" PUSH BUTTON 5 " PUSH PLATE OUTLETS See Page 40 18 21 2 22 20 6 FOOT PEDAL REPAIR
More informationHVAC Automatic Balance Valve Index
HVC utomatic alance Index Weights Individual Weights Y-all Models Flow Rate (GPM) Connection Size Page 2519 0.50-5.00 1/4 to 3/4 V-SPEC-2519 2518 0.50-5.00 1/2 to 3/4 V-SPEC-2518 2517 0.50-9.00 1/2 to
More informationPP1 Series Piping Packages for VG1000 Series Ball Valves
PP Series Piping Packages for VG000 Series Ball s Product Bulletin PP2xxxxx- Series, PP8xxxxx- Series Code No. LIT-20974 Issued August, 204 PP Series Piping Packages are designed to provide an easier way
More informationModel descriptions. 2. For other pressure and temperature limits, consult ANSI B16 cast iron flange standards.
VALVES & CONTROLS KUNKLE SAFETY AND RELIEF PRODUCTS Cast Iron Liquid Relief Valves Model 228 Model descriptions Model 91: Bronze trim, with pressure-tight cap. Suitable for maximum back pressure of 60
More informationB2/B3 Series Characterized Control Valve, Non-Spring Return Actuator
/3 Series Characterized Control Valve, Non-Spring ctuator Two-way and Three-way Valves with Chrome Plated rass all and rass Stem, NPT Female Ends Service: Flow characteristic: Media Temp Range: mbient
More informationThis valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style
Code No. LIT-1973 Issued July 1, 6 V46 Series Pressure Actuated Water Regulating Valve Description The V46 is a pressure actuated, modulating valve that is suitable for use either on closed or open systems.
More informationPRESSURE CONTROL VALVES SABS 198
PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge
More informationCompact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe
Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe SERIES Features Industrial quality miniature actuator Industrial grade True Union ball valve Visual valve position indicator
More informationRegenerative Turbine Pumps
Bulletin E4 November 009 E4 T4 Series Regenerative Turbine Pumps Capacities to GPM Heads to 600 Feet Temperatures to 00 F MTH PUMPS MTH E4 T4 Series Close-coupled and pedestal mounted regenerative turbine
More informationHenderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS
SECTION 220523 - GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS 1.1 SUMMARY A. This Section includes general duty valves common to most plumbing piping systems. 1. Special purpose
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 230519 - METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ABBREVIATIONS A. Degree
More informationM-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components
Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options
More informationPowers Controls Powertop Two-Way Valves Normally Open
Powers Controls Powertop Two-Way s Normally Open VP 658-5 Description The VP 658 normally open valves are pneumatically operated valves designed to control the flow of both water and steam. Features Stainless
More informationPumps Certified for North American Market
Pioneering for You Version 2015/09 Pumps Certified for North American Market Subject to change without prior notice WLO SE Introduction History In 1872, Louis Opländer founded Wilo as a copper a brass
More informationLK Manifold Shunt VS2
LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.
More informationP200 Pressure Regulator
P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,
More informationLiebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller
DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe
More informationLF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem
/ Series Characterized Control Valve, Spring ctuator Two-way and Three-way Valves with Chrome Plated rass all and rass Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: mbient Temp
More informationTP 25-80/2-A-O-A-BQQE 400Y 50HZ
GRUNDFOS DATA BOOKLET TP 25-80/2-A-O-A-BQQE 400Y 50HZ Grundfos pump 98282096 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp000/98282096/tp-25-80-2-a-o-a-bqqe.html
More informationPump Stations for Heating Circuits
Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu
More informationVOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)
VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC) Document No. 129-464 VOG15 March 30, 2010 Description Oil Safety Shutoff Valve The VOG15 is an electro-hydraulically actuated
More informationMVD, MV, MKV, MKL, 2161C, MXV Series
MVD, MV, MKV, MKL, 2161C, MXV Series Float-type air vent valves Technical Data Sheet WattsIndustries.com Description DUOVENT MVD and MVDR Series, MINIVENT MV and MVR Series, MICROVENT MKV, MKVR, MKL and
More informationFeatures. HTHP Filter Press for Drilling Fluid Testing DRILLING FLUIDS EQUIPMENT
HTHP Filter Press for Drilling Fluid Testing DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion
More informationModulating Water Valves and Bulb Wells
Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature
More informationFeatures. HTHP Filter Press for Drilling Fluids, 500 ml DRILLING FLUIDS EQUIPMENT
HTHP Filter Press for Drilling Fluids, 500 ml DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements,
More informationunderfloor heating PRODUCTS FOR UNDERFLOOR HEATING
underfloor heating PRODUCTS FOR UNDERFLOOR HEATING Table of Contents LK 420 Minishunt... 3 LK 421 Manifold Shunt... 4 LK 422 Manifold Shunt... 5 Spare Parts and Accessories... 6 LK 430 Manifold... 7 LK
More informationTP 32-90/2-A-O-A-BQQE 400Y 50HZ
GRUNDFOS DATA BOOKLET TP 32-9/2-A-O-A-BQQE 4Y 5HZ Grundfos pump 98346582 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/98346582/tp-32-9-2-a-o-a-bqqe.html
More information