3SB5. Indicating lamps and push buttons. Answers for industry.
|
|
- James McCarthy
- 5 years ago
- Views:
Transcription
1 3SB5 Indicating lamps and push buttons Answers for industry. s
2 Blank Page
3 Commanding and Signalling Devices 2 Introduction 3SB5 Pushbutton Units and Indicating Lamps, 22 mm 4 General data Actuators and Indicating Lamps, Plastic, 22 mm 6 Actuators Contact block 10 Indicating lamps 11 Illumination module Accessories and Spare Parts 12 Pusher caps 12 Lamps 12 Protective covers 13 Miscellaneous accessories Enclosures 15 General data 16 Enclosures with standard fittings 18 Empty enclosures 1 Contact blocks and lampholders 1 Accessories for enclosures
4 3SB5 Commanding and Signalling Devices Introduction Overview 3SB5 Pushbutton units and indicator lights Designs Nominal diameter Version Actuators Pushbutton actuators - opaque Pushbutton actuators - illuminated Selector actuators - opaque Selector actuators - illuminated Key actuators E-stop mushroom actuators Twin push buttons - opaque Twin push buttons - illuminated Indicators Compact indicators - LED Compact indicators - Filament Wide voltage band indicators - LED Modular indicators Contact blocks Compact Regular Illumination Modules Integrated LED BAS LED BAS Filament Connections Screw terminals 22 mm Plastic, round 2
5 3SB5 Commanding and Signalling Devices Introduction 3SB5 Enclosures Enclosures Plastic Metal Actuators Pushbuttons and switches Illuminated pushb. and switches Mushroom pushbuttons Push-pull buttons EMERGENCY-STOP mushroom pushbuttons Selector switches Locks Indicators Indicator lights Contact blocks Single-pole Two-pole Terminals Screw terminals 3
6 3SB5 Pushbutton Units and Indicating Lamps, 22 mm General data Overview Panel door 3SB5 compact pilot light 3SB5 twin push button 1. Compact Indicating lamp 2. Panel door 3. Ring holder 1. Twin Push Button Actuator 2. Panel door 3. Holder with Contact Blocks 4
7 General data Actuator Design The 3SB5 series is a modular range of commanding and signalling devices for front panel mounting and rear conductor connection. One command position comprises: An actuator or lens assembly in front of the control panel A holder for mounting behind the control panel Up to 3 contact blocks and/or 1 lampholder behind the control panel A comprehensive range of accessories for inscription Two contact blocks can be snapped onto the actuator in the standard version. Holder for 3 contact blocks or for 2 contact blocks and 1 lampholder Thrust pad for actuating a central contact block when using selector actuator and key actuator Thrust cap for actuating a central contact block when using push button actuator For all executions the holder is included as standard. Standards IEC , IS Connection methods The devices are available with screw terminals. The devices are of modern industrial design and can be mounted rapidly by a single person. The operating surfaces of the pushbuttons and illuminated pushbuttons are concave. The lenses of the indicator lights are convex. 5
8 Actuators, Plastic, 22 mm Actuators Selection and ordering data Pushbuttons with holder Version Colour Order No. Weight per Opaque normal Red 3SB AC Green 3SB AE Blue 3SB AF White 3SB AG Yellow 3SB AD Black 3SB AB Opaque raised Red 3SB LC Green 3SB LE Blue 3SB LF White 3SB LG Yellow 3SB LD Black 3SB LB Illuminated normal Red 3SB AC01-0PQ Green 3SB AE01-0PQ Amber 3SB AL01-0PQ Blue 3SB AF01-0PQ White 3SB AG01-0PQ Yellow 3SB AD01-0PQ Clear 3SB AH01-0PQ Illuminated raised Red 3SB LC01-0PQ Green 3SB LE01-0PQ Amber 3SB LL01-0PQ Blue 3SB LF01-0PQ White 3SB LG01-0PQ Yellow 3SB LD01-0PQ Clear 3SB LH01-0PQ Twin pushbutton with holder Opaque twin 3SB EC pushbutton with 1NO & 1NC Illuminated twin 1) 3SB EC pushbutton with 1NO & 1NC 1) Use illumination module with integrated LED only 6
9 Actuators, Plastic, 22 mm Actuators Mushroom pushbuttons with holder Version Colour Order No. Weight per Mushroom pushbuttons, Ø 40 mm Black 3SB NB momentary Red 3SB NC Mushroom pushbuttons, Ø 40 mm Black 3SB CB push to trip, turn to release Mushroom pushbuttons for emergency stop Mushroom pushbuttons with 1NC Red 3SB UC push to trip, turn to release Mushroom pushbuttons, Ø 40 mm Red 3SB UC push to trip, turn to release Mushroom pushbuttons, Ø 40 mm Red 3SB VC push to trip, pull to release Mushroom pushbuttons, Ø 40 mm Red 3SB TC push to trip, key to release 7
10 Actuators, Plastic, 22 mm Actuators Selector switches with holder Version Version Colour Order No. Weight per 2 position Selector switches with 2 switch positions Switching sequence O-I, Opaque Black 3SB AB operating angle Maintained Red 3SB AC Switching sequence O-I, Opaque Black 3SB BB operating angle Momentary Red 3SB BC Switching sequence O-I, Illuminated Red 3SB AC operating angle Maintained Green 3SB AE Blue 3SB AF Yellow 3SB AD Clear 3SB AH Switching sequence O-I, Illuminated Red 3SB BC operating angle Momentary Green 3SB BE Blue 3SB BF Yellow 3SB BD Clear 3SB BH position Selector switches with 3 switch positions Switching sequence I-O-II, Opaque Black 3SB DB x 50 operating angle Maintained Red 3SB DC Switching sequence I-O-II, Opaque Black 3SB EB x 50 operating angle Momentary Red 3SB EC x 50 operating angle Illuminated Red 3SB DC Maintained Green 3SB DE Blue 3SB DF Yellow 3SB DD Clear 3SB DH Switching sequence I-O-II, Illuminated Red 3SB EC x 50 operating angle, Momentary Green 3SB EE Blue 3SB EF Yellow 3SB ED Clear 3SB EH Key-operated switches with holder Version Key removal Order No. Weight per position Key-operated switches with 2 keys & 2 switch positions Switching sequence O-I, L - KR 3SB AC operating angle, maintained KL - R 3SB AA KL - KR 3SB AB Switching sequence O-I, KL < R 3SB TA operating angle, momentary L > KR 3SB TC Key-operated switches with 2 keys & 3 switch positions Switching sequence I-O-II, L - KC - R 3SB HA x 50 operating angle, maintained KL - C - KR 3SB HC KL - KC - KR 3SB HB Switching sequence O-I, L > KC < R 3SB JA x 50 operating angle, momentary * Key removable position L - Left, R - Right, C - Centre, KL - Key at Left, KR - Key at Right, KC - Key at Centre 8
11 Components for Actuators Selection and ordering data Contact blocks Version Symbols Operating travel Order No. Weight per Contact closed Contact blocks for front plate mounting Contact open Contact blocks with one contact Mounting depth: 50 mm 1 NO 3SB B NC 3SB C Contact blocks with 2 contacts Mounting depth 63 mm (including unit labeling plate) 1 NO + 1 NC 3SB A NO 3SB E NC 3SB F 0.018
12 Indicating Lamps Indicating lamps Selection and ordering data Compact LED indicating lamp Compact BAs filament indicating lamp Version Rated Voltage Colour Order No. Weight per V Compact LED indicating lamp 24 V AC/DC Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG V AC Red 3SB HC /60 Hz Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG Yellow 3SB HD Clear 3SB HH V Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG Yellow 3SB HD Clear 3SB HH /240 V AC Red 3SB HC /60 Hz Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG Yellow 3SB HD Clear 3SB HH V Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG Yellow 3SB HD Clear 3SB HH Compact BAs filament indicating lamp 24 V AC/DC Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF Clear 3SB HH V AC/DC Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF Clear 3SB HH V AC/DC Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF Clear 3SB HH Compact indicating lamp without lamp $ To be used with BAs filament Red 3SB HC lamp of appropriate voltage Green 3SB HE Amber 3SB HL Blue 3SB HF Clear 3SB HH Indicators Wide band LEDs 42 V to Red 3SB HC V AC Green 3SB HE /60 Hz Amber 3SB HL & Blue 3SB HF V to White 3SB HG V DC Yellow 3SB HD Clear 3SB HH10 Use of bridge rectified DC source (filtered O/P) recommended $ To be used with BAs filament lamp at appropriate / required voltage. Bulb will be at an additional charge 10
13 Indicating Lamps Indicating lamps Modular indicating lamps Illumination module with integrated LED Illumination module with BAs LED Version Rated Voltage Colour Order No. Weight per V Lens assembly with holder Red 3SB BC Green 3SB BE Amber 3SB BL Blue 3SB BF White 3SB BG Yellow 3SB BD Clear 3SB BH Lamp holder with integrated LED 24 V AC/DC Red 3SB CC Green 3SB CE Amber 3SB CL Blue 3SB CF White 3SB CG* Yellow 3SB CD V AC Red 3SB EC Green 3SB EE Amber 3SB EL Blue 3SB EF White 3SB EG* Yellow 3SB ED V Red 3SB DC Green 3SB DE Amber 3SB DL Blue 3SB DF White 3SB DG* Yellow 3SB DD V AC Red 3SB TC Green 3SB TE Amber 3SB TL Blue 3SB TF White 3SB TG* Yellow 3SB TD V Red 3SB HC Green 3SB HE Amber 3SB HL Blue 3SB HF White 3SB HG* Yellow 3SB HD Illumination module with BAs filament lamp Lamp holder with BAs LED 24 V AC/DC Red 3SB CC Green 3SB CE Blue 3SB CF Yellow 3SB CD V AC/DC # Red 3SB FC Green 3SB FE Blue 3SB FF Yellow 3SB FD V AC # Red 3SB SC Green 3SB SE Blue 3SB SF Yellow 3SB SD Lamp holder with BAs 24 V AC/DC (24 V lamp) 3SB CC filament lamp 110 V AC/DC (130 V lamp) 3SB FH V AC/DC (230 V lamp) 3SB LH * Can be used with clear Use of rectified DC source (filtered O/P) recommended # With voltage reducer Note: All illumination modules can be used along with illuminated push buttons, illuminated selector actuators and modular indicating lamps. 11
14 Accessories and Spare Parts Accessories and spare parts Selection and ordering data Version Colour Order No. Weight per Pusher caps and lenses Normal opaque Red 3SB5 10-0AC For opaque pushbuttons Green 3SB5 10-0AE Blue 3SB5 10-0AF White 3SB5 10-0AG Yellow 3SB5 10-0AD Black 3SB5 10-0AB Raised opaque Red 3SB5 10-0BC For opaque pushbuttons Green 3SB5 10-0BE Blue 3SB5 10-0BF White 3SB5 10-0BG Yellow 3SB5 10-0BD Black 3SB5 10-0BB Normal illuminated Red 3SB5 10-0CC For illuminated pushbuttons Green 3SB5 10-0CE Amber 3SB5 10-0CR Blue 3SB5 10-0CF White 3SB5 10-0CG Yellow 3SB5 10-0CD Clear 3SB5 10-0CH Raised illuminated Red 3SB5 10-0DC For illuminated pushbuttons raised Green 3SB5 10-0DE Amber 3SB5 10-0DR Blue 3SB5 10-0DF White 3SB5 10-0DG Yellow 3SB5 10-0DD Clear 3SB5 10-0DH Lenses Red 3SB5 10-1PC For indicator lamps Green 3SB5 10-1PE Amber 3SB5 10-1PR White 3SB5 10-1PG Yellow 3SB5 10-1PD Clear 3SB5 10-1PH Lamps Version Rated Voltage Colour Order No. Weight per V BAs filament lamp 6V/2W 3SB5 02-6A V/2W 3SB5 02-6B V/2W 3SB5 02-6C V/2.5W 3SB5 02-6D V/2.5W 3SB5 02-6E BAs LED 24V AC/DC Red 3SB5 02-3FK Green 3SB5 02-3GK Blue 3SB5 02-3JK Yellow 3SB5 02-3HK Protective caps 1), degree of protection IP67 Version Use Colour Order No. Weight per Protective caps Flat button (plastic) Clear 3SB5 02-0AK Protective caps Raised button (plastic) Clear 3SB5 02-0AN
15 Accessories and Spare Parts Selection and ordering data Accessories and spare parts Version Order No. Weight per Holders for commanding and signalling elements Holders 3SB5 12-0BA For plastic version, round Holders 3SB5 11-1AA 0.00 Metallic for front connection Inscription labels Inscription label With set of 11 (Start, Stop, On, Off, Up, Emergency OFF, Down, Open, Close, Forward, Reverse) Inscription label With set of 10 (Right, Left, Test, Reset, Auto O Man, Inch, Trip, Slow, Fast) E-stop yellow dia. 75 mm with EMERGENCY STOP printing (yellow contrast label) 3SB5 01-3EA 3SB5 01-3CH 3SB5 21-0AD E-stop yellow dia. 75 mm for mushroom blank (yellow contrast label) 3SB5 21-0AB Inscription plates Twin push button spares and accessories Inscription plates Start 3SB5 01-2EL Stop 3SB5 01-2EK ON 3SB5 01-2EB OFF 3SB5 01-2EC Up 3SB5 01-2ED Down 3SB5 01-2EE Forward 3SB5 01-2EF Slow 3SB5 01-2ES Fast 3SB5 01-2ER Reverse 3SB5 01-2EG Black 3SB5 01-2AA Trip 3SB5 01-2EA Lens 3SB5 12-0BB
16 3SB5 Pushbutton Units and Indicating Lamps, 22 mm Accessories and Spare Parts Accessories and spare parts Other accessories Version Order No. Weight per Adapter plate for replacing 30 mm by 22 mm 3SB5 21-0AE Lamp extractors 3SB5 02-2AD For lamps with BA s lamps and LEDs Plastic front ring 3SB5 11-1BA Thrust cap for pushbuttons for actuating middle module 3SB5 02-0AA Thrust pad for selector actuators 3SB5 12-0AN for actuating middle module 14
17 Enclosures General data Overview Enclosures with standard fittings Top part 2. Inscription labels 3. Contact block 4. Bottom part of enclosure Enclosed pushbutton units and indicating lamps are used as hand operated control devices for separately allocated control units and cabinets. The devices are suitable for use in any climate. Standards IEC , IS Enclosures with handle are available for suspension (e.g. for crane control units). Overview Enclosures with standard fittings are available with: 1 to 3 command positions in metal / plastic enclosures 1 way is available in 2 colours, grey & yellow Operational voltage up to 440 V Vertical mounting type Empty plastic enclosures are available in 6 and 4 way Contact blocks for base mounting (are snapped into the enclosure base). Screw terminals as standard. Colour of enclosure cover: Gray, RAL 7035, or Yellow, RAL 1004 (1 way only) Colour of enclosure base: Black, RAL
18 3SB5 Pushbutton Units and Indicating Lamps, 22 mm Enclosures Customer-specific enclosures Overview Operational voltage up to 400 V One command position comprises: 1 actuator or indicator Up to 3 contact blocks or up to 2 contact blocks + 1 lampholder 1 inscription label For plastic and metal enclosures the command positions are equipped as standard with actuators. For routing the cable in, one hole for M20 (for 1 to 3 command positions) or for M25 (for 4 or 6 command positions) is provided at the top and bottom. Selection and ordering data Metal enclosures Plastic enclosures Version Number of Order No. Weight per command positions Normal opaque push button - Green with 1 3SB AA NO contact block, START Red mushroom momentary actuator, with 1 3SB AN NC contact block, STOP Red maintained mushroom actuator, turn to 1 3SB AM release, with 1NC contact block, E-STOP Normal opaque push button - Green with 2 3SB AC NO contact block, START + Normal opaque push button - Red with 1NC contact block, "STOP" Normal opaque push button - Green with 2 3SB AE3 1NO contact block, START + Red mushroom-maintained with 1NC contact block, STOP Normal opaque push button - Green with 3 3SB AH NO contact block, FORWARD + Normal opaque push button - Red with 1NC contact block, "STOP" + Normal opaque push button - Black with 1NO contact block, REVERSE Normal opaque push button - Green with 1 3SB AA NO contact block, START Red mushroom momentary actuator, with 1 3SB AN NC contact block, STOP Red maintained mushroom actuator, turn to 1 3SB AM release, with 1NC contact block, E-STOP Normal opaque push button - Green with 2 3SB AC NO contact block, START + Normal opaque push button - Red with 1NC contact block, "STOP" Normal opaque push button - Green with 2 3SB AE NO contact block, START + Red mushroom-maintained with 1NC contact block, STOP Normal opaque push button - Green with 3 3SB AG NO contact block, FORWARD + Normal opaque push button - Red with 1NC contact block, "STOP" + Normal opaque push button - Black with 1NO contact block, REVERSE 16
19 Enclosures Customer-specific enclosures Pendant mounting Version Number of Order No. Weight per command positions Normal opaque push button - Green with 2 3SB AC NO contact block, START + Normal opaque push button - Red with 1NC contact block,"stop" Normal opaque push button - Green with 3 3SB AH NO contact block, FORWARD + Normal opaque push button - Red with 1NC contact block,"stop" + Normal opaque push button - Black with 1NO contact block, REVERSE 17
20 Enclosures Empty enclosures Version Number of Colour Order No. Weight per command positions Empty enclosures, plastic 1 to 3 command positions, 4 and 6 command positions 1 Grey 3SB AC Grey 3SB AC Grey 3SB AC Grey 3SB AC Grey 3SB AC Yellow 3SB AD Empty enclosures, metal 1 to 3 command positions 1 3SB AC SB AC SB AC
21 Enclosures Selection and ordering data Lampholders and contact blocks Version Rated Voltage Screw terminals Weight per V BAs lampholder Order No. BA s lampholders Without lamp 110 V AC/DC 3SB PF V AC/DC 3SB PL Contact blocks with one contact Contact blocks with one contact 1 NO 3SB B NC 3SB C Accessories Version Order No. Weight per Set of 11 labels 3SB5 01-3EA Start, Stop, ON, OFF, Up, Down, Open, Close Forward, Reverse, Emergency Off Tool for fitting actuator on metal enclosure 3SB5 02-2BX 1
22 Blank Page
23 Commanding and Signalling Devices 22 Introduction 3SB5 Pushbutton Units and Indicating Lamps, 22 mm 23 General data 24 Technical data 3SB5 Pushbutton Units and Indicating Lamps, 22 mm Enclosures 25 General data 27 Project planning aids
24 3SB5 Pushbutton Units and Indicating Lamps, 22 mm Technical data General data Overview Front plate mounting 3SB5 compact pilot light 3SB5 twin push button 1. Compact Indicating lamp 2. Panel door 3. Ring holder 1. Twin Push Button Actuator 2. Panel door 3. Holder with Contact Blocks 22
25 Technical data General data Design Holders The holders are used for mounting the actuating or signalling elements and are plugged into the rear of the panel door. The holder for the round versions is set to a switchboard thickness of 1 to 6 mm. When label holders, protective caps or similar accessories are used, the greatest permissible panel thickness must be reduced by the wall thickness of the accessory part. Contact blocks and lampholders The contact blocks are fitted with (1 NO contact or 1 NC contact) with double operating contacts. These ensure a high switching reliability even with small voltages and currents, such as 5 V/1 ma. The switch contacts of the NC contact are positively driven. For illuminated elements, lampholders with an integrated LED or with a base for replaceable bulbs can be supplied. For indicating lamps holder, ring holder helps in faster assembly thus reducing installation time. Wider voltage range 3SB5 wide band indicating lamps are supplied with integrated LEDs. This would help in reducing the inventory cost. Mounting The 3SB5 devices can be easily and quickly mounted: Actuators or indicator lights are positioned in the opening of the front panel from the front Position the holder from the rear Tighten the screw on the holder Snap on the contact block or the lampholder directly onto the actuator from the back Connection methods The following devices are available: Screw terminal (SIGUT termination) The devices with screw terminals have open terminals, screws that cannot be lost, funnel-shaped cable entries and screwdriver fed openings, all of which saves time when connecting and enables the use of motorized screwdrivers. Enclosures Plastic enclosures are available with 1, 2, 3, 4 or 6 command positions. Metal enclosures are available in 1, 2 or 3 command positions. 23
26 Technical data General data Pushbuttons, indicating lamps and LED pilot lights Rated insulation voltage U i All executions except lamp holder AC 60V, 50Hz BAs lamp holder AC 250V, 50Hz; DC 250V Illumination module with integrated LED / AC 440V, 50Hz; DC 250V Compact Pilot Light Rated operational voltage U e For contact blocks 660V, 50Hz For Illumination modules with integrated LED 24V AC/DC, 110V AC, 110V DC, 230V AC, 220V DC For Illumination modules with BAs LED lamp 24V AC/DC, 110V AC/DC, 240V AC For Illumination modules with BAs filament lamp 24V AC/DC, 110V AC/DC, 230V AC/DC For Compact LED indicating lamps 24V AC/DC, 110V AC, 110V DC, 220/240V AC, 220V DC For compact BAs filament indicating lamp 24V AC/DC, 110V AC/DC, 230V AC/DC Wide band LED indicating lamp 42V to 240V AC & 42V to 220V DC Back-up HRC fuse rating 16A quick acting cartridge 10A delayed acting cartridge Mechanical life All actuators (except the following) 10 x 10 6 cycles Luminous actuators 3 x 10 6 cycles Selector, key and latched mushroom actuator 3 x 10 5 cycles Electrical life Depends on load current e.g. 10 x 10 6 cycles with 3TH30, 3TF30/31 contactors Illumination Wide band LED 100 lux minimum Discrete voltage and LED and BAs filament lamps 300 lux minimum Switching frequency 1200 cycles per hour Degree of protection Pushbuttons & Indicating Lamps Standard execution - IP65 With protective cover - IP67 Terminals of contact blocks and illumination modules Standard execution - IP20 Permissible service temperature range -25 C to +60 C Terminal capacity Finely stranded cable with end sleeves 2 x 0.5 to 1.5 mm 2 Solid conductor 2 x 1 to 2.5 mm 2 Solid conductor with end sleeves 2 x 0.5 to 0.75 mm 2 Finely stranded cable with end sleeves 2 x 1 to 1.5 mm 2 (for compact variants) Continuous current, rated operational current Ie, contact blocks Contact block / Illumination module configuration I e /AC 12 I e /AC 15 U e Volts (40-60 Hz) I e /DC 12 I e /DC 13 U e Volts DC 10 A 6 A 24 V 10 A 6 A 24 V 6 A 110 V 8 A 4 A 48 V 6 A 220/230 V 3.5 A 1.2 A 110 V 4 A 380/400 V 1 A 0.4 A 220 V Actuator - Illuminated Push button and selector Voltage Max. possible Max. possible contact blocks Accessory to operate lamp holders (1st block-left, 2nd-right, middle contact block (lamp holder 3rd-middle) (Order separately & always in snap-fit on actuator) middle Rear Front position) connection connection With BAs LED 24V AC/DC 2 2 Not applicable 110V AC/DC, V AC 1 1 With BAs 24V AC/DC Not applicable Filament lamp 110 V AC/DC, V AC Integrated LED 24V AC/DC, 110V AC 1 2 Not applicable 230V AC Actuator / Opaque Push button 3 3 Thrust cap Selector 3 3 Thrust pad Key 3 3 Thrust pad Mushroon Thrust cap momentary 24
27 Enclosures Technical data General data Overview Enclosures with standard fittings Top part 2. Inscription labels 3. Contact block 4. Bottom part of enclosure Enclosed pushbutton units and indicator lights are used as hand operated control devices for separately allocated control units and cabinets. The devices are suitable for use in any climate. Standards IEC , IS Enclosures with handle are available for suspension (e.g. for crane control units). The following versions are available: Enclosure with standard fittings with 1 to 3 command positions Empty enclosures (individual parts must be ordered separately). 25
28 Enclosures Technical data General data Design Enclosures Plastic enclosures with 1, 2, 3, 4 or 6 command positions are available. Metal enclosures with 1, 2 or 3 command positions are available. Cable routing: on the top and bottom narrow ends of the enclosure for an M20 or M25 metric cable gland. Enclosure colour: Cover: RAL 7035 (light gray), For EMERGENCY-STOP: RAL 1004 (yellow), Base: RAL 005 (black). The plastic enclosures comply with the total insulation protective measure. Actuators Round actuators and lens assemblies for a nominal diameter of 22 mm can be used. The actuators are fitted through the hole in the cover of the enclosure and are connected to the holder supplied with the actuator and secured in position. Plastic and metal enclosures are equipped as standard with actuators and indicators made of plastic. Contact blocks and lampholders Contact blocks and lampholders for base mounting are snapped into the bottom part of the enclosure. For each command positions, the following components can be fitted: 3 contact blocks or 2 contact blocks + 1 lampholder The contact blocks have moving double-break contacts and therefore a high contact. 26
29 Dimensional drawings Mounting details for cylinder Ø22 mm Technical data Project planning aids Normal Push Button Actuator with Holder and 1NC Contact Block Normal Push Button Actuator with Holder Raised Push Button Actuator with Holder Selector Actuator with Holder Mushroom Twist to release Actuator with Holder Mushroom Momentary Actuator with Holder 27
30 3SB5 Pushbutton Units and Indicating Lamps, 22 mm Technical data Project planning aids Key Actuator with Holder 2NO/2NC/1NO+1NC Contact Block (Front Mounting) 1NO/1NC Contact Block (Front Mounting) BAs Lamp Holder Wide Band LED with Holder and Lens Assembly Twin Push Button Actuator with Holder Integrated LED Lens assembly with Holder Compact LED/BAs Pilot Light 28
31 Technical data Project planning aids 1NC/1NO Contact Block (Base Mounting) Push Button Enclosures (Plastic & Metal) Lamp holder front connection Pendant Push Button Enclosures (Metal only) Numbers of command points a b Numbers of command points a
32 Your partners Sales offices: Ahmedabad 3rd Floor, Prerna Arbour Girish Cold Drinks Cross Roads, Off. C. G. Road Ahmedabad : Fax: Bengaluru 1st Floor, Jyothimahal, #4, St. Marks Road Bangalore : Fax: Chandigarh SCO 18-11, 3rd Floor, Sector 17C Chandigarh : Fax: Chennai 4, Mahatma Gandhi Road, Chennai : Fax: Coimbatore 7th Floor, East Wing, Global Towers 1057, Avinashi Road, Coimbatore : Fax: Hyderabad 5--1, Lakshmi Narsinh Estate, 4th Floor Secretariat Road, Opp. Secretariat, Saifabad Hyderabad : Fax: Kolkata 43 Shanti Palli, R B Connector Eastern Metropolitan Bypass, Kolkata : , Fax: / 13 Lucknow 28/45, Ashok Marg, Opposite Indira Bhawan Lucknow : , Fax: Mumbai R&D and Technology Centre th Floor, Thane-Belapur Road Thane , India : Fax: Nagpur 5th Floor, Landmark Building, Ramdas Peth Nagpur : Fax: New Delhi 4A, Ring Road, I.P. Estate, New Delhi : Fax: Pune Tower B / , ICC Trade Tower 403A, Senapati Bapat Road, Pune : Fax: Territory managers: Aurangabad A, Yogeshwari Vrundavan, Nr. Malhar Chowk Garkheda Parisar, Prema Nagar Aurangabad , Maharashtra Mobile: santosh.rajhans@siemens.com Bareilly Bareilly , Uttar Pradesh Mobile: saket.dwivedi@siemens.com Mobile: ankur.singh@siemens.com Baroda 1st Floor, Vaniiya Bhavan, Race Course Road Baroda , Gujarat : /12, Mobile: ankur.chokshi@siemens.com Mobile: bhushan.sawant@siemens.com Belgaum H.No.713, Narvekar Lane, Shahpur Belgaum , Karnataka & Fax: Mobile: anand.gawade@siemens.com Bhilai C/o Mr. S.H Siddiqui Sector-1, Street-, Quarter No 1A Bhilai , Chhattisgarh Mobile: Bhopal Flat No - 104, Sagar Home Phase-2 Sarvadharma Society, Nayapura Road Bhopal , MP Mobile: Prajwal.khapekar@siemens.com Bhubaneswar Flat No.10, Hara Priya Aparment Vivekananda Marg, Bhubaneswar , Orissa : Mobile: anirban.aditya@siemens.com Mobile: sumit.sengupta@siemens.com Calicut Kozhikode, Calicut , Kerala Mobile: sreekanth.p@siemens.com Deharadun B 76, Kumar Gali, Ajabpurkalan Deharadun , Uttarakhand Mobile: manish.bajpai@siemens.com Durgapur Durgapur , West Bengal Mobile: chattopadhyay.suman@siemens.com Faridabad House No 237, Sector-8 Faridabad , Haryana Mobile: ramit.mehra@siemens.com Gurgaon House No-38, Second Floor, Sector-30 Gurgaon , Haryana Mobile: manjeet.mor@siemens.com Guwahati G1, Hill View Apartment, Navagraha Path Chenikuthi Hill Side, Guwahati , Assam : Mobile: sourav.bhattacharya@siemens.com Mobile: biplab.datta@siemens.com Hardwar 6, Nand Puri, Near Arya Nagar Chowk, Jwalapur Hardwar , Uttarakhand Mobile: Fax: ankur.singh@siemens.com Indore Flat No. 102, Panchvati Apartment 40 Chandralok Colony, Khajrana Road Indore , Madhya Pradesh Mobile: prashant.joshi@siemens.com Jaipur 6, Park Street, Opp Pink City Petrol Pump, M.I.Road Jaipur , Rajasthan : / Fax: Mobile: peeush.gupta@siemens.com Jalandar H.No 448R, First Floor, Pushpa Niwas Near Geeta Mandir, Model Town Jalandar , Punjab Mobile: sunil.singla@siemens.com Jamshedpur 823, Udaigiri, Vijaya Heritage, Uliyan, Kadma Jamshedpur , Jharkhand : Mobile: shaibal.parial@siemens.com Jodhpur 371, Gauri House, Kamala Nehru Nagar Near SBI Bank, Jodhpur , Rajasthan Mobile: naveen.sahariya@siemens.com Kanpur 106, Agarwal Aparment Near Hari Har Dham Mandir, Shyam Nagar Kanpur , Uttar Pradesh & Fax: Mobile: atul.shukla@siemens.com Kochi KG Oxford Business Centre, 3/460, Third Floor Sreekandath Road, Ravipuram Cochin , Kerala : , 22 Fax: Mobile: Sajeen sajeen.s@siemens.com Mobile: Sudheer E mail: sudheer.ts@siemens.com Kolhapur Flat No. 101, Shrushti Mahabharat Apartment Mahavir Garden To Mahavir College Road Nagala Park, Kolhapur , Maharashtra : Mobile: sachin.chavan@siemens.com Ludhiana H.No 3746, First Floor, Sector 32-A Chandigarh Road, Ludhiana , Punjab Mobile: rajeev.kapoor@siemens.com Ludhiana H.No 2, Lajpat Nagar, Near Bus Stand Ludhiana , Punjab : Mobile: rohit.jagga@siemens.com Madurai 8/12, Ground Floor, Sakhti Vellammal Street SS Colony, Madurai , Tamilnadu Mobile: mahendiran.murugan@siemens.com Nashik "Aditya Avenue", Flat No. 27, 4th Floor B Wing, Near Chandak Circle, Tidke Colony Nashik , Maharashtra Mobile: kiran.kanhurkar@siemens.com Pondicherry 32, Second Floor, St. Theresa Street Pondicherry : Mobile: lakshamanan.s@siemens.com Raipur Flat No.103, First Floor, Block B, Shilp Enclave Near LAS Colony, Shankar Nagar Raipur , Chhattisgarh Mobile: brajesh.rathor@siemens.com Rajkot "Vrujraj", 4 Chandanpark Society Opp. Gyanganga Vidhyapith, Nr. Raiya Circle Rajkot , Gujarat Mobile: hiren.raythatha@siemens.com Ranchi H-1/187, Harmu Housing Colony, Harmu Ranchi , Jharkhand Mobile: sourav.dasgupta@siemens.com Renukoot Above ICICI Prudentail Office, Patel Nagar Murdhawa, Dist-Sonebhadra Renukoot , Uttar Pradesh Mobile: bhav.srivastava@siemens.com Rourkela T-15, Civil Town, Rourkela , Orissa : Mobile: sanjoy.ganguly@siemens.com Rudrapur Rudrapur , Uttarakhand Mobile: singh.ajay@siemens.com Salem 3/25 Santosh Nagar, PACB Backside Chinnathirupathi, Salem , Tamilnadu Mobile: rubengerald@siemens.com Sambalpur Pradhan Para, Near Jamkani Mandir Beside LIC Div Off, Ainthapalli Sambalpur , Orissa : Mobile: samir.chaintak@siemens.com Surat Flat No. 202, D-1, Suryam Residence Cause Way Road, Opp. Hari Darshan Shinganpor - Dabholi Road, Katargam Surat , Gujarat Mobile: chandrakant.keshrani@siemens.com Tiruchirappali Door No. 106, Ground Floor, 5th Cross Street Vidhyasalai Road, Ganapathy Nagar Thiruvanaikoil, Trichy Tiruchirappali , Tamilnadu & Fax: Mobile: k.saravanakumar@siemens.com Thiruvanandapuram Sonu, TC/2082, 5, Thamarakulam Lane Sathamangalam, Trivendrum , Kerala Mobile: jonsa_82@yahoo.com Udaipur 303, Oasis Park, PP Singhal Marg, Ambavgarh Udaipur , Rajasthan & Fax: Mobile: ajit.parashar@siemens.com Vapi Flat No. 302,Samrajya IV, Royal Residency Gokul Vihar Township, Charwada Road Vapi , Gujarat : Mobile: sachin.paradkar@siemens.com Vijayawada G-2, Shreya Tower, Moghalrajapuram Near Jammichettu Centre Vijayawada , Andhra Pradesh : Mobile: santosh.p@siemens.com Visakhapatanam Flat No. 401, Door No Vinayagar West Avenue, CBM compound Visakhapatanam , Andhra Pradesh : Mobile: ksv.prasad@siemens.com Siemens Ltd. Industry Sector Industry Automation - Control Components Thane Belapur Road, Thane Fax: lvsgr-mktg.india@siemens.com Order No.: SGR Customer Care Toll free no adscs.india@siemens.com Product upgradation is a continuous process. Hence, data in this datasheet is subject to change without prior notice. For the latest information, please get in touch with our Sales Offices.
3SB5. Indicating lamps and push buttons. Answers for industry.
3SB5 Indicating lamps and push buttons Answers for industry. s Blank Page Commanding and Signalling Devices 2 Introduction 3SB5 Pushbutton Units and Indicating Lamps, 22 mm 4 General data Actuators and
More informationLV HRC Fuses: DIN Type
s LV HRC Fuses: DIN Type Geared up for any situation Answers for Infrastructure. Fuses are the fastest & simplest current limiting devices. With a wide current range, multiple voltage ratings and high
More informationComplete protection made easy
s Complete protection made easy HRC fuses - BS type Answers for infrastructure. Siemens offers 3NW BS type of fuses suitable for use in both industrial and building applications. These fuses are available
More informationSmart choice for power distribution. Datasheet. sentron
Smart choice for power distribution Datasheet sentron s Introducing Sentron VT A new generation of Moulded Case Circuit Breakers (MCCBs) The compact design of Sentron VT family of Moulded Case Circuit
More informationLow Voltage Motors. Your choice can leave an indelible mark on the environment. Answers for industry.
Your choice can leave an indelible mark on the environment Low Voltage Motors LP-Mot/191, Maximum Retail Price w.e.f 6 th January 2011 This supercedes all previous Price Lists. Answers for industry. s
More informationGeared up for any situation. Fuses HRC. Answers for industry.
Geared up for any situation Fuses HRC Answers for industry. s HRC Fuses Type Introduction 3NA3 Short data description : 3NA7 LV HRC Fuses Standards IS 13703 Part 2 Section 1(1993); IEC 269 Dimensions IS
More informationPower Distribution Redefined. Superswitch. Answers for industry.
Power Distribution Redefined Superswitch Answers for industry. s Superswitch 3KL8/ 3KT8/ 3KA8 Highlights Switch Disconnector fuse from 20A to 800A in 2P, 3P+N and 4P Versions. Switch Disconnector available
More informationComplete protection made easy. Datasheet. hrc fuses BS TYPE
Complete protection made easy Datasheet hrc fuses BS TYPE General Siemens low voltage HRC fuses of BS type have been developed for industrial applications. Due to the special design, they provide high
More information3SB5 Operating Instruction Manual
perating nstructions SB5 perating nstruction Manual Warning : Hazardous Voltage can cause Electric Shock and burns. Disconnect Power before proceeding with any work on this equipment SB5 Mounting details
More informationPush Button Units and Indicator Lights
3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,
More informationSITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI
Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk
More informationControl Circuit Components Push Button Units and Indicator Lights
Control Circuit Components Push Button Units and Indicator Lights Contents Pages Section Overview......................... 0/2-0/3 3SB2, 6mm Mounting Diameter Pilot Devices Introduction....................................
More informationManual changeover switches & Automatic transfer switches
Manual changeover switches & Automatic transfer switches Manual ChangeoverSwitches 63A to 1600A Advantagesforyou: Doublebreakperpolefacilitalingsuitabilityforisolationasper IEC60947-3 Safeisolationat0positionformaintenance
More informationLimit Switches and Safety
and Safety Introduction Overview 3SE5 23., 3SE5 21. 3SF1 2.4 3SE5 24., 3SF1 244 3SE5 13., 3SE5 11., 3SF1 114 3SE5 12., 3SF1 124 3SE5 16. 3SE5 232, 3SE5 212, 3SF1 2.4 3SE5 132, 3SE5 112, 3SF1 1.4 Position
More informationThe most widely used motors from the world leaders
he most widely used motors from the world leaders MBA & HX+ Pa e Pap Steel Cement Cement p r EFC, S1 Duty 4 ± % V, Hz ± %. Combined Variation (absolute sum %) Insulation Class F Ambient temp C emperature
More informationMotor Protection Circuit Breaker
Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6
More informationCapacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks.
Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks. Stiff Boom Cranes Motor Grader PTR Model Load Capacity Power Tyres Wheel (s) Fork Height (std.) Fork Size (LxWxT) Tilt
More informationAutomatic Star Delta Starters IEC : 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved
Agriculture Starter complying to latest standards Automatic Star Delta Starters IEC 60947-4-1: 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved www.siemens.co.in Tried, Tested and Trusted
More informationKare Zindagi Instant Start
Kare Zindagi Instant Start KIND ATTENTION t In event of any particular model being phased out or out of stock, the Company reserves the right to provide another equivalent model of same capacity best
More informationSingle Phase Submersible Pump Starters
Single Phase Submersible Pump Starters Starters Single Phase Submersible Pump Starter BCH Electric Limited manufactures a wide range of motor starters to suit every application in the field. BCH introduces
More informationQuality Products, Prompt Service, Trustful Relationships.
SINCE www.kmindustrialcorp.com Quality s, Prompt Service, Trustful Relationships. KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry Goods for
More informationPrice list 03/2018. w.e.f. April 1, 2018
list 03/18. w.e.f. April 1, 18 Sl.No. Cable Size Box Dimensions (LXBXH) (mm) WITHOUT WITH TERMINALS TERMINALS Cable Junction Boxes IP with membranes for cable entry - sq.mm 76 x 76 x 3 DE 92 170.00 DE
More informationHRC Fuse-links Bolted Type HG 2 A - 32 A HQ 2 A A
HRC Fuse-links Bolted Type HG 2 A - 2 A - 630 A HRC Fuse-links Bolted Type Larsen & Toubro Limited, India s largest manufacturer of low tension switchgear, offers FN range of SDFs suitable for Bolted Type
More informationPosition and Safety Switches
Siemens AG 20 Position and Safety Switches groups 41K, 42A /2 Introduction SIRIUS 3SE5 mechanical position switches /4 General data 3SE5, plastic enclosures /13 - Enclosure width 31 mm acc. to EN 50047
More informationTM Ser i es. Tr uc k Mounted Cr anes. Rugged and reliable truck mounted cranes
SPARE PARTS & SERVICE ACE has all India Sales and Service network operating out of all the major cities. These outlets are fully equipped to provide genuine spare parts and services by company trained
More informationPartnership that you can trust. LV Switchgear Motor Control Products.
s Partnership that you can trust LV Switchgear Motor Control Products Maximum etail Price w.e.f. st October, 204 www.siemens.co.in s SIMOCODE pro S Get your motor control center s intelligent and compact
More informationHeavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return
CONTROLS Division of A-T Controls Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to,600,000 in. lbs. Double Acting and Spring Return THD S E R I E S The Triac line
More informationACX 750. Hydraulic Crawler Crane 75 tons Capacity. High performance rough terrain and rugged crawler crane.
ACX 0 Hydraulic Crawler Crane tons Capacity. High performance rough terrain and rugged crawler crane. Robust and sturdy design Best in class lifting duties Hydraulically extendable tracks Easy transportation
More informationCatalog. Low voltage General performance IE3 efficiency cast iron motors
Catalog Low voltage General performance IE3 efficiency cast iron motors ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 2 General performance IE3 efficiency cast iron
More informationAPPENDIX A Instruction Set. Op Code. T states Flags Main Effects. Instructions
APPENDIX A 8085 Instruction Set Instructions ACI byte CE 7 ALL A A + CY + byte ADC A 8F 4 ALL A A + A + CY ADC B 88 4 ALL A A + B + CY ADC C 89 4 ALL A A + C + CY ADC D 8A 4 ALL A A + D + CY ADC E 8B 4
More informationLABOUR CHARGES - BODYPAINT JOBS. Applicable for Group I+ Cities New GenVerna (HCi)
Applicable for Group I+ Cities New Gen / / with Clear / / TLi / / / / / / / with Clear with Clear 44 390 67 4990 880 08 880 08 629 440 880 08 690 82 98 220 6840 649 7740 737 6830 810 904 9430 938 981 981
More informationOverload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview
SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.
More informationML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A
ML Series Contactor & Thermal Overload Relay Technical Data Type Cat. No. Conformance Standards No.of poles Thermal rating / Utilization category AC-1 :, 415V, 50Hz* Insulation voltage, U (V) I) Stator
More informationHarmony Ø 22 Control and Signalling units
Schneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS) For more information visit our website at: www.schneider-electric.co.in Corporate Office : A-29, Mohan Co-operative
More informationPlastic enclosures compact Of polycarbonate. Degree of protection: IP 66, 67, 69K UL type1, 3R, 4, 4X, 12, 13
Pilot devices, 22 mm Assembled stations and enclosures Assembled stations There are assembled stations of two types: In plastic enclosures and in metallic enclosures Both types of enclosures are available
More informationRange : 7.5kW to 630/800kW
Range : 7.5kW to 630/800kW ATS 48 PRESENTATION Altistart 48 is a high performance soft starter using 6 thyristors for controlled starting of 3 phase asynchronous squirel cage induction motors. It provides
More informationSwitch-Disconnector-Fuse HRC Fuse-links Bolted Type
Switch-Disconnector-Fuse HRC Fuse-links Bolted Type HRC Fuse-links Bolted Type Larsen & Toubro Limited, India s largest manufacturer of low tension switchgear, offers new FN range of SDFs suitable for
More informationEnergy Saving HRC Fuse-Links
Energy Saving HRC Fuse-Links Cylindrical, Bolted & Blade Type About us Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced
More informationTerminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals
Terminal Blocks 2013 Product Catalog Terminal Block Supplement Introduction 8WH6 ipo Plug-In Terminals 8WH6 ipo Installation Terminals 8WH2 Spring-Loaded Terminals 1 2 3 4 8WH 8WH5 Combination Plug-In
More informationSITRANS P measuring instruments for pressure
Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)
More information3VT Kompaktleistungsschalter bis 630A
Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical
More informationWORM GEARS STIRRER UNITS
WORM GEARS STIRRER UNITS PREMIUM ADAPTABLE SPEED REDUCERS Premium Stirrer Units form the most comprehensive range available to industry. They are based on the standard V type single reduction Premium Worm
More informationIndustrial Controls. 8WN Signaling Columns.
s Industrial Controls 8WN Signaling Columns www.siemens.co.in 8WN signaling columns 8WN44 Signaling columns, 70mm diameter, modular Selection and ordering data Buzzer elements Version Rated voltage Color
More informationEnergy Saving HRC Fuse-Links
Energy Saving HRC Fuse-Links Cylindrical, Bolted & Blade Type About us Larsen & Toubro infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationControl & Signalling Devices 22.5 mm. RoHS. Compliant
Control & Signalling Devices 22.5 mm RoHS Compliant Contents Characteristics General Characteristics Products Push Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated
More informationSIRIUS 3RU2 Thermal Overload Relays
Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to
More informationDATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved
DATE: May 19, 2000 (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved SUBJECT: MODELS AFFECTED: TIME OF COMPLIANCE: Approved Slick Magnetos on Textron Lycoming Engines See
More informationSpectronic-SP Air Circuit Breaker
Spectronic- Air Circuit Breaker Circuit Breakers 800 to 2500A Series Rated Short circuit breaking capacity : lcs 50 to 55KA ( 4 15V) Complete range Fixed with manual control 3 or 4 poles Electrical control
More informationTHD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs
CONTROLS Division of A-T Controls, Inc. THD Series Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 In-lbs Double Acting and Spring Return Symmetric and
More informationNATIONAL HOUSING BANK. Press Release
NATIONAL HOUSING BANK Press Release NHB RESIDEX RESIDENTIAL HOUSING PRICE INDEX Update for the Quarter July-September, 2017 (Q2 2017) NHB RESIDEX, India s first official housing price index (HPI), was
More informationDelta Power Company 4484 Boeing Drive - Rockford, IL 61109
VALVE CATALOG MAIN INDEX RELEASED DATE: JUNE 03. QUICK SELECTION GUIDE Page SOLENOID OPERATED DIRECTIONAL CONTROLS (See ENGINEERING DATA for coil specs) Page 7 MECHANICAL DIRECTIONAL CONTROLS Page 5 PRESSURE
More information8WH2 Spring-Loaded Terminals
8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25
More informationSITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369
and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting
More informationINTERNATIONAL PASSENGERS
ANNEXURE-IIIA INTERNATIONAL PASSENGERS (A) 20 INTERNATIONAL S 1 CHENNAI 517067 472427 9.4 2544451 2304518 10.4 2 KOLKATA 219052 205611 6.5 1097596 1026969 6.9 3 AHMEDABAD 171380 143821 19.2 823520 705823
More informationSIVACON Power Distribution Boards, Busway Systems and Cubicle Systems
SIVACON Power Distribution Boards, Busway Systems and Cubicle Systems /2 Introduction 8PV, 8PT Power Distribution Boards and Motor Control Centers /7 General data 8PS Busbar Trunking Systems /8 Introduction
More informationINSTRUMENT PANEL CLUSTERS
INSTRUMENT PANEL CLUSTERS NOT BUYING AT THIS TIME REVISED ##### PART # MAKE APPLICATION 6/18/2018 PRICE 56045618 CHRY IPC 40.00 56045679 CHRY IPC 40.00 56051103 CHRY IPC 40.00 56049833 AC,AD CHRY IPC 40.00
More information8WH6 ipo Installation Terminals
/2 Introduction /4 8WH through-type terminals /6 8WH through-type screw terminals /8 8WH N-conductor isolating terminals /10 8WH N-conductor isolating screw terminals /12 8WH installation terminals More
More informationCLOGGING INDICATORS SUMMING-UP DESCRIPTION
SUMMINGUP CLOGGING PRESSURE FILTERS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential,
More informationEVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS. - Pdf manuals & parts catalogs library
R EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS FOR COMPRESSOR APPLICATIONS. Cummins Presence in Compressor Industry One that keeps your package performing optimally, while keeping the maintenance
More informationOrder No. of the options EMC filter Class A
Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationRecord SL. Moulded Case Circuit Breaker
Record SL Moulded Case Circuit Breaker The new GE Record SL Moulded Case Circuit Breaker family is a line of reliable, simple and easy to use protection devices for use in both moderate or hot and humid
More informationMeeting with Commissioner, Kendriya Vidyalaya Sangathan (KVS) New Delhi 11 April 2016
Chariot Wheel Konark Sun Temple, Odisha Konark Sun Temple is a 13th Century Sun Temple Meeting with Commissioner, Kendriya Vidyalaya Sangathan (KVS) New Delhi 11 April 2016 Solar potential in the country
More informationINTERNATIONAL FREIGHT
ANNEXURE-IVA INTERNATIONAL FREIGHT (A) 20 INTERNATIONAL S 1 CHENNAI 27035 25605 5.6 52663 49971 5.4 2 KOLKATA 4800 6027-20.4 9351 10918-14.4 3 AHMEDABAD 3910 3800 2.9 7222 6910 4.5 4 GOA 126 104 21.2 244
More informationA9K. MCB, RCCB, Isolator
A9K MCB, RCCB, Isolator Schneider Electric - The global specialist in energy management and automation brings 80 years of experience to India with more than 70,000 people in over a 00 countries We Reduce
More informationSOLID STATE BUZZER ABSOLUTE CONTROL
TM TEKMEC SOLID STATE BUZZER ABSOLUTE CONTROL TEKMEC TM PERFECTION C O M M I T M E N T PCMS M3111204IN (AN ISO 9001:2008 CERTIFIED COMPANY) CONTROLLING DEVICES SIGNALLING DEVICES Ø22.5MM CONTROL & SIGNALLING
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationTable 1d - FSA for All Returns, Females Tax Year
PR 10 Newfoundland and Labrador A0A 20,250 597,345 1,920 1,720 2,580 3,150 1,960 1,610 1,360 1,030 1,020 740 550 460 630 470 410 290 290 70 20 A0B 8,850 249,804 780 740 1,200 1,520 1,010 790 540 430 370
More information3SB 22mm Pilot Devices
3B mm Pilot Devices Illuminated elector witches election AssembledLess Contacts Illuminated elector witch Operator with Holder Operator Descr Full AC/DC Transformer AC 8 6 Resistor AC/DC 3B-3MFA* 3B-3MFB*
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More information27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10
27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2
More informationAF09... AF96 3-pole contactors Accessory fitting details
AF9... AF96 3-pole contactors Accessory fitting details Contactor and main accessories (other accessories available) AF9... AF65 AF contactor (without top mounted coil terminal block) VEM4 mechanical and
More informationVACUUM PUMP. Material of Construction: Applications:
VACUUM PUMP Material of Construction: (as applicable) Rotor(Impeller) Applications: Priming of large pumps Evacuation of air from suction pipes and chambers Specific Applications: Twist drilling machine,
More informationCFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI
CFR Series Coils, Transformers OUTLINE Power inductors for preventing the diffusion of noises generated from power circuits and suppressing noise components coming through the power lines. ø8.7 ø11 max.
More informationThe Product Range. Technical Data
The Product Range Section 3.1 - Basic Cylinder Bore sizes (mm): 10, 16, 25, 32, 40, 50 The basic cylinder series satisfies the support and guidance requirements of a great diversity of applications. Various
More information8WH6 ipo Plug-In Terminals
/ Introduction /3 /4 8WH6 through-type terminals /8 8WH6 fuse terminals /9 8WH6 isolating blade terminals /11 8WH6 isolating terminals /13 8WH6 two-tier terminals More technical product information: Service&Support
More informationDC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS
Crompton Greaves EVERYDAY SOLUTIONS DC MOTORS LT MOTORS DIVISION A - 6/2, M.I.D.C., AHMEDNAGAR - 414111. MAHARASHTRA. TEL : +91 (0241) 2776 151-154, 2776146, 2776187. FAX : +91 (0241) 2777508 INTRODUCTION
More informationPrice List. Power Factor. With effect from June 15, Correction Products. With effect from January 03, 2012
Price List Power Factor With effect from June 15, 2011 With effect from January 03, 2012 Price List Contents Power factor correction b Box Type 440V Range.............................. 1 b Can Type 440V
More information8WH2 Spring-Loaded Terminals
8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25
More informationSSR SSR SSR SSR
DMX 52 Page DMX52 decoder firing board module 20 VAC reference Input 2 3 4 The Thyristor Firing board is compatible withdmx52 control standard 4 DMX52 triggers 2 3 4 - +- +- +- + The can trigger control
More informationControl Units Ex e Glass Fiber Reinforced Polyester
Features Assembly Glass fiber reinforced polyester (GRP) enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de, Ex ib and Ex tb Up to 4 operators per control unit, base-mounted contact
More informationMOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:
MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER 15-24 Date: 11-19-2015 SUBJECT: MODELS/ S/N AFFECTED: To ADVISE MOONEY OWNERS/OPERATORS of the LYCOMING Service Instruction
More informationFlame Proof Motors For Hazardous Environment JHX
Flame Proof Motors For Hazardous Environment JHX troduction The use of electrical motors in potentially explosive atmospheres is quite frequent these days. These motors have to be constructed in such a
More informationC & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL
C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL OPERATING HEADS, - IP65 CONTROL UNITS WITH CHROMIUM PLATED METAL BEZEL PROJECTING PUSH BUTTON BOOTED PUSH BUTTON IP66 WITH TRANSPARENT BOOT IP66 MUSHROOM
More informationEnclosures and assembled
Enclosures and assembled stations Enclosures and assembled Stations Large plastic enclosure (Modular & Compact) This enclosure can fit both Modular and Compact operators with the unique possibility to
More informationThe GLC. Make the best of every ground.
The GLC. Make the best of every ground. 1 Ever higher. Further ahead. Encounter every drive on a whole new level: with the GLC. More progressive and more athletic than ever before, yet virtually silent
More information2. COMPACT CYLINDERS series STRONG (RS, RQ)
2. COMPACT CYLINDERS series STRONG (RS, RQ) A new series of compact cylinders for long s and heavy-duty applications standard supplied with oversized guides and rods, the first one with adjustable pneumatic
More informationAbout us. L&T now introduces compact range of 'Load Break Isolators' to suit the needs of Isolation for every safety needs. Switchgear Factory, Mumbai
Load Break es About us Larsen & Toubro is a technology-driven USD.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,
More information7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.
1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.
More informationThe specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.
General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front
More informationMiniature Valves MH1. Extremely small, fast and versatile. Info 206
Miniature Valves MH1 Extremely small, fast and versatile Info 206 MH1 Miniature Valves Benefits and Applications of the MH1 Miniature Valve The MH1 offers maximum reliability, even in constant operation
More informationPneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552
Pneumatic cylinders, piston-ø 32 100 mm Double acting with magnetic piston DIN ISO 15552 Technical data for series SL 050 450 Order code SL-032-0250-050 Series Piston-Ø Stroke length (mm) Type of cylinder
More informationOf Excellence ELEVATORS BIRLA GROUP COMPANY. APTO We Keep You Moving... Always. Truly Indian.
Of Excellence ELEVATORS BIRLA GROUP COMPANY APTO We Keep You Moving... Always www.eceelevators.com Truly Indian If you have travelled in India, chances are you have travelled with us inside many prestigious
More informationMANATECTM. World Class Garage Equipment MANATEC TOTAL SOLUTION
MANATECTM Partners in Progress World Class Garage Equipment 02. 03. Company Profile & Manatec's Growth Path Company Milestones 04. R&D Milestones 05. Exports Product Range 06. Product Range (LCV & HCV)
More informationELEVATE TO A BETTER LIFE ELEVATORS BIRLA GROUP CO.
ELEVATE TO A BETTER LIFE ELEVATORS BIRLA GROUP CO. We are ECE... We keep you moving... Always! Established in 1945, ECE is one of the leading domestic brand names in electrical equipment and elevators
More informationLET THE SUN POWER YOUR HOME
LET THE SUN POWER YOUR HOME Havells Residential Solar Grid-Tie Inverter 7 Years Introduction of Havells Havells India Limited is a leading Fast Moving Electrical Goods (FMEG) Company and a major power
More informationJFB 15 / 20 / 25 / 30 Josts Electric Counterbalance Trucks (Capacity 1500 / 2000 / 2500 / 3000 Kg)
JFB 15 / 2 / 25 / 3 Josts Electric Counterbalance Trucks (Capacity 15 / 2 / 25 / 3 Kg) (AC Drive) - ENVIRONMENT FRIENDLY - HIGH PERFORMANCE - EASY OPERATION - SUPERIOR SAFETY - EASY MAINTENANCE - UNMATCHED
More informationRAFIX 22 QR. General data. Content
QR General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A
Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air
More information