PROPOSAL. Fume-A-Vent 4 Drop Source Capture Diesel Fume Extraction System for Firehouse/EMS

Size: px
Start display at page:

Download "PROPOSAL. Fume-A-Vent 4 Drop Source Capture Diesel Fume Extraction System for Firehouse/EMS"

Transcription

1

2 PROPOSAL Page 1 of HORAN DRIVE FENTON, MO Phone: (636) Fax: (636) Order Number: Order Date: Salesperson: Customer Number: /20/2017 Dan Schroeder FIRE Sold To: Firehouse Budgetary Proposal 4 Drop Station Ship To: Firehouse Budgetary Proposal 4 Drop Station QTY PART NUMBER DESCRIPTION PRICE AMOUNT Fume-A-Vent 4 Drop Source Capture Diesel Fume Extraction System for Firehouse/EMS SD-0512 Fume-A-Vent 5" Simple Drop System with Stainless Steel & rubber tailpipe adapter and spring clip auto release nozzle. Includes 12' x 5" high temperature hose, 80" mounting bracket, support legs and apparatus tailpipe modification kit. F.O.B. Fenton, MO 1, , PB B PB Series Cast Aluminum Pressure Blower 5 HP, 3 Phase, 1,756 4" w.g. Bottom Horizontal, 8" Inlet & 8" Outlet F.O.B. Mason, OH 2, , ***1 PHASE POWER OPTIONS AVAILABLE, PLEASE CONSULT SALES TEAM*** CBS T Fume-A-Vent Control Box Starter with low voltage landing terminals.features a mild-steel NEMA 4 enclosure with 3-way (HAND-OFF-AUTO) switch and reset button. For use with a 230V, 5HP, 3PH Fan and compatible 230V, 3PH source. Includes an off-delay timer. 1, , BDD-08 Fume-A-Vent 8" Upblast Back Draft Damper NF-FAV Nordfab Quick-Fit Laser Welded Clamp-together Duct System 2, , Drop as per attached CAD drawing A F.O.B. Thomasville, NC ***PLEASE ALLOW TWO WEEKS PLUS SHIPPING TRANSIT*** ***FREIGHT CHARGES TO BE INVOICED SEPARATELY*** Continued

3 PROPOSAL Page 2 of HORAN DRIVE FENTON, MO Phone: (636) Fax: (636) Order Number: Order Date: Salesperson: Customer Number: /20/2017 Dan Schroeder FIRE Sold To: Firehouse Budgetary Proposal 4 Drop Station Ship To: Firehouse Budgetary Proposal 4 Drop Station QTY PART NUMBER DESCRIPTION PRICE AMOUNT Packing Instructions: Shipping Instructions: CUSTOMER P.O.: SHIP DATE: SHIP VIA: TERMS: F.O.B.: PRICE QUOTE BEST WAY CREDIT CARD SEE ABOVE CONFIRM TO: Fire Chief NET ORDER: 12, SALES TAX: 0.00 ORDER TOTAL: 12,011.83

4 Fume-A-Vent Automatic Release Clamp On Nozzle Date 9/17 Part No. TPA Emergency Apparatus TAB 13-C 5" 7 2" Apparatus Tailpipe " 3" Rubber Nozzle - 6" ID. Made of High temperature Synthetic Rubber. 2 Spring Clamp - 6" x 2" spring clamp designed to clamp on vehicle tailpipe. 3 Reducing Elbow - 6" to 5" 60º stainless steel reducing elbow. 4 Hose Clamp - Stainless Steel hose clamp. 5 Tailpipe - 4" Vehicle exhaust system tailpipe. 6 Tailpipe Adapter - Clamp on tailpipe adapter. Designed to adjust the distance the FUME-A-VENT spring clamp clamps on to the tailpipe. Provides leverage for automatic release the when the apparatus exits the engine house. 7 Connected view shows the spring clamp connected to the apparatus tailpipe. 8 End view shows the 6" nozzle connected to 4" tailpipe. 826 Horan Drive Fax info@fumeavent.com This drawing has been copyrighted and is the property of Air Cleaning Specialists, Inc.

5 Fume-A-Veny System Overview Date 09/17 Page C-10 Mounting Bracket Overview TAB 13-C Horan Drive Fax This drawing has been copyrighted and is the property of Air Cleaning Specialists, Inc.

6 Fume-A-Vent PB Series - Pressure Blowers Date 10/12 PBX-X-X-X Fans And Blowers TAB 12 This exhaust fan is designed for the purpose of exhausting most particulates as well as volatile organic compounds (VOC s) created by internal combustion engines. These fans feature high pressure 3/16" minimum thickness radial flat wheels, direct drive, and are AMCA Type B spark resistant. Housing shall be of Aluminum/Magnesium alloy created by 2- piece construction with gaskets and steel hardware. Fan shall be in tested accordance with AMCA Standard #210. The motor is TEFC UL and CSA rated, and factory balanced by removal of material with no additional weights used. It shall run at 3450 RPM and can operate under normal temperatures up to 150 degrees. Motor bases made with 12 gauge steel minimum. High temperature upgrades available for use up to 400 degrees and 750 degrees. To be manufactured in the United States and meets all local, state, and federal government standards. Fan base is painted 10 gauge steel with Stainless Steel option. We offer from 0.5 H.P. Motors to 10 H.P. with 1 or 3 Phase options, and can be customized to your needs. Arrangement 4 direct drive standard. Mounting, electrical, CFM, dimensions, and other specifications available upon request. Shown below is our normal discharge options, consult our experts for custom options and applications. CW Bottom Horizontal Discharge CW Top Horizontal Discharge CW Up Blast Discharge 826 Horan Drive Fax info@fumeavent.com This drawing has been copyrighted and is the property of Air Cleaning Specialists, Inc.

7 Fume-A-Vent Engine Sensor Control Panel Diagram 3 H.P. Date 2/14 Part No. CBS-X-XXX-X Control Panels TAB 19-C-1 Fume A Vent Control Panel Enclosure Drawing. shown below. This drawing applies to all 230V Panels, up to 3 H.P. Our Control Panels come standard with 3 way (HAND OFF AUTO) switch and reset button, and low voltage landing terminals. Motor starts, contractor and thermal overloads also included. Standard Dimensions shown below, with orthographic drawing of the entire enclosure. More information available upon request. Please contact our experts for more information. Final wiring and appearance may change once final layout and needs are decided upon. Standard Control Panel shown with on/off switch. 826 Horan Drive Fax info@fumeavent.com This drawing has been copyrighted and is the property of Air Cleaning Specialists, Inc.

8 Quick-Fit THE WORLD S FASTEST DUCTING Q-F puts the squeeze on costly conventional duct Installation. Q-F is a snap! No complicated cutting, no riveting, no braising or welding are required. One Q-F clamp connects sections together in seconds. Branches, diverters, elbows - all adapt easily to your existing duct and may be taken apart and re-used or cleaned without special tools. Q-F is easy to install, easy to align, and it s strong! Q-F clamps are so easy to install, they almost install themselves. Simply place the clamp over the Q-F rolled lip ends and snap! The extraordinary strength of Q-F s specially machined double rolled lips provides a solid, straight run. The patented Q-F clamp connects the rolled ends. Snap the Q-F clamp and you have the strongest, safest, most re-usable dust-extraction piping available today. No special instructions or skills are needed to assemble a Q-F system. Install new lines, clean out lines or make changes to existing duct runs anytime you need to with Q-F. Q-F adapts to your every need; connect to the old or bring in the new. Q-F has everything you need in galvanized or stainless steel parts: * LASER WELDED pipe in diameters from 3 to 24 * Branch fittings in all sizes and shapes * Elbows 30 o, 45 o, 60 o, 90 o * Larger custom sizes and special adapters * Blast Gates, Diverter Valves, Hoods, Manifolds. Q-F adjusts to fit - without complicated measurements. LASER WELDED SEAM Planning to add, remove, or replace dust-extraction piping? Q-F s adjustable fittings slide together to create the precise length. No need for time wasted on exact measuring and precision cuts. Simply slide on and fit to your desired length, a few inches or a few feet. Need a different length for a new run? Just re-use your Q-F components and re-fit, again reducing your cutting and fabricating time. Q-F saves you time and money. Just how much money can you save using Q-F? Call us! You will be pleased with the savings and all the built-in advantages you get with Q-F. Whether you need just a few parts, or help with a complete system, Q-F has 4 to 5 day lead time. Call for a free sample. Air Cleaning Specialists Inc. 826 Horan Drive Toll Free: Fax:

9

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10

More information

SECTION DUST COLLECTOR

SECTION DUST COLLECTOR PART1-GENERAL 1.1 DESCRI PTION A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract Drawings. 1.2 SUBMITTALS

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

DUST, FUME, TRIM & WASTE REMOVAL

DUST, FUME, TRIM & WASTE REMOVAL METFLO DUCT COMPONENTS DUST, FUME, TRIM & WASTE REMOVAL H-P Products, Inc. 800.860.TUBE (8823) Fax: 330.875.7155 www.metflo.com 1 Services INDEX SERVICES.... 2 SPECIAL PARTS.... 3 ROLLED LIP DUCT Straight

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

Fume-A-Vent Motorized Hose Reel

Fume-A-Vent Motorized Hose Reel Fume-A-Vent Motorized Hose Reel Date 7/12 Part No.HRM XX-XX-XX Hose Reels TAB 3-C-1 Shown Above: Fume-A-Vent Model HRM-2-0620 Motor Hose Reel with 5" x 20' Series 2 600 Rubber impregnated Polyester Hose.

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

EASY DUCT - AN INVESTMENT IN YOUR FUTURE

EASY DUCT - AN INVESTMENT IN YOUR FUTURE EASY DUCT EASY DUCT - AN INVESTMENT IN YOUR FUTURE LOWER COST THAN CONVENTIONAL JOINING METHODS Easy Duct clamp-together ducting eliminates rivets, screws, welds and other time-consuming and costly joining

More information

Catalog Made in the USA. The world s fastest ducting. Easy & fast to install Easy to remove for cleaning Laser welded seams Re-useable

Catalog Made in the USA. The world s fastest ducting. Easy & fast to install Easy to remove for cleaning Laser welded seams Re-useable 800-532-0830 www.nordfab.com ID:040114A Easy & fast to install ID: 010113 Easy to remove for cleaning Laser welded seams Re-useable Cuts installation and downtime by more than 45% Catalog 2014 Made in

More information

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product Combustion North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product FEATURES Direct drive blowers specifically for combustion

More information

easy duct - an investement in your future

easy duct - an investement in your future easy duct easy duct - an investement in your future LOWER COST THAN CONVENTIONAL JOINING METHODS Easy Duct clamp-together ducting eliminates rivets, screws, welds and other time-consuming and costly joining

More information

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED BC 09 Pressure Relief Dampers PRD-GAB-12B Table Of Contents S. No Description Page No 1 General Information 1 2 PRD/NRD- B10 Series 2 3 CBD - B20 Series 3 4 BDD - B30 Series 4 5 Engineering and Performance

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Made in the USA

Made in the USA QF Quick-Fit 2017 Catalog Made the USA www.nordfab-us.com 800-532-0830 Nordfab Ductg The World s Fastest Ductg Nordfab s Quick-Fit (QF ) is The World s Fastest Ductg every aspect of your dust collection

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

ENGINEERED FOR EXCEPTIONAL PERFORMANCE.

ENGINEERED FOR EXCEPTIONAL PERFORMANCE. ENGINEERED FOR EXCEPTIONAL PERFORMANCE. FIRST AND ONLY MOTORIZED ARM ON THE MARKET The SCA608, 610, and 614 P models feature a linear actuator that moves the arm up and down electronically. This allows

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 MARCH, 2014 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below

More information

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships Diversified Air Systems, Inc. Exhaust hose reels Car and truck dealerships RV, off-road maintenance shops Motorcycle and snowmobile dealerships Diesel fumes and smoke exhaust Spring operation or motorized

More information

RF Dust Collectors. Torit Data Sheet. Models 48RF8-484RF12

RF Dust Collectors. Torit Data Sheet. Models 48RF8-484RF12 Torit Data Sheet RF Dust Collectors Models 48RF8-RF1 Reliable, simple design and energy-efficient operation to handle high-volume dust collection applications. If you are dealing in applications where

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 SEPTEMBER, 2011 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

Dust Collectors and Fume Exhausters

Dust Collectors and Fume Exhausters www.americanfan.com Bulletin DFM 1600 Dust Collectors and Fume Exhausters Howden Industrial Fan Group American Fan /Joy Fan /Garden City Fan Model DC DUST COLLECTOR The Model DC is a low cost packaged

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

EZTray. Cable Management Made Easy

EZTray. Cable Management Made Easy EZTray Cable Management Made Easy PRESENTATION Introduction:.................................. 3 EZ Tray: The Tray That Saves You Time!.............. 4-5 EZ Tray: The Innovative Cable Management Solution....

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

WELD STRONG BREATHE FREE

WELD STRONG BREATHE FREE WELD STRONG BREATHE FREE WELD STRONG BREATHE FREE VentBoss was born from your needs; TOUGH, durable fume control equipment for today s metal fabricators. QUALITY products made in the US, backed by 20+

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Comply with the above specifications? Yes No

Comply with the above specifications? Yes No The Exhaust Removal System shall be 100% re-circulating, fully automatic, ceiling hung filtration system that addresses the problem of diesel/gas fumes in the Fire station and does not interfere with normal

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

A. NU2035 HRV Specifications NU2035

A. NU2035 HRV Specifications NU2035 A. NU2035 HRV Specifications NU2035 B. Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

SECTION WELDING FUME EXHAUST SYSTEM

SECTION WELDING FUME EXHAUST SYSTEM SECTION 233500 WELDING FUME EXHAUST SYSTEM PART 1 - GENERAL 1.1 WORK INCLUDES Welding fume exhaust system and controls Accessories Additional System Equipment Engineering Support Commissioning 1.2 RELATED

More information

Replacement Parts List

Replacement Parts List Replacement s List Includes Illustrations and Replacement s Dryflo Mist Collectors and Patent s: 5,611,922 6,007,608 This manual is property of the owner. Leave with the unit when set-up and start-up are

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

MIMPEN0410. Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S

MIMPEN0410. Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S MIMPEN0410 Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S AQC Dust Collecting Systems This manual is the property of the owner.

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury

More information

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow. NU1030 HRV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

More information

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

HARTZELL. Power Roof Ventilators. Hartzell Fan, Inc., Piqua, Ohio

HARTZELL. Power Roof Ventilators. Hartzell Fan, Inc., Piqua, Ohio Power Roof Ventilators Upblast Hooded Recirculating Smoke Ventilators Series 61 & 63 Series 15, 16 & 17 Series 26 & 27 Series 69H Series 69 & 69S Series 71J, 73J & 75J BUILT WITH HONOR HARTZELL FAN, INC

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

Optimizing Airflow on Dust, Mist and Fume Collection Systems

Optimizing Airflow on Dust, Mist and Fume Collection Systems Optimizing Airflow on Dust, Mist and Fume Collection Systems Extend filter life. Conserve energy. Save money. by Lori Lehner, Donaldson Torit Technical Training Manager Optimizing airflow control in your

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow. NU2540 ERV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

More information

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration -MC -MC Diversified Air Systems, Inc. pantone 2756 Portable filtration unit / 650 CFM (305 L/s) pantone 2756 Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration 99.9% efficiency

More information

THE ENVIROMAC MOBILE AIR CLEANER ( ) OWNER S MANUAL

THE ENVIROMAC MOBILE AIR CLEANER ( ) OWNER S MANUAL THE ENVIROMAC MOBILE AIR CLEANER (107.1020.001) OWNER S MANUAL In Canada: Enviroflex International Inc. 17 Brownridge Rd., Unit 8 Brampton, Ontario L7G 0C6 Phone: (905) 636-1177 Fax: (905) 636-1178 Web

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing Soldering/Desoldering Convection Rework Fume Extraction Fluid Dispensing www.beasuperproducer.com BVX-100 Benchtop Single User Arm/Plenum System Portable, single user fume extraction system Low noise unit

More information

Portable HEPA System

Portable HEPA System Operation and Maintenance Manual Portable HEPA System Series - PHS MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 PORTABLE HEPA SYSTEM GENERAL INFORMATION SAFETY PRECAUTIONS: Keep all paper work

More information

General Safety Information

General Safety Information Part #01248 Manual #PMEB-1010 Supersedes #PMEB-409 OPERATING INSTRUCTIONS & PARTS LIST FUME EXHAUSTERS MODELS EBR and EBM Read instructions carefully before attempting to assemble, install, operate, move,

More information

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24 72 Diameter Bulletin PF-1410 July 2003 A Fläkt Woods Company PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003 Fläkt Woods Group Creative Air Fläkt Woods was created by bringing together several of the worlds leading players

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,

More information

CBI JET SERIES. Corrosive. Backward. Inclined. Special Design for: ! Research Centers. ! Laboratory Hood Exhaust. ! Industrial Fume Exhaust

CBI JET SERIES. Corrosive. Backward. Inclined. Special Design for: ! Research Centers. ! Laboratory Hood Exhaust. ! Industrial Fume Exhaust CBI JET SERIES Corrosive Backward Inclined Special Design for:! Research Centers! Laboratory Hood Exhaust! Industrial Fume Exhaust! Waste Water Treatment! Roof or Duct Mounted CBI JET Series Characteristics

More information

Propeller Fan BE Series

Propeller Fan BE Series Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST FAN THESE LOW PRESSURE BELT DRIVEN FANS ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

quatroair.com AIR TECHNOLOGIES INC.

quatroair.com AIR TECHNOLOGIES INC. quatroair.com AIR TECHNOLOGIES INC. LaserBlue Gel Zero Filter Bypass. Guaranteed! Designed to meet the most stringent cleanroom requirements, the LaserBlue gel forms an impenetrable barrier against the

More information

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation. Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation. Unmatched Cleaning Efficiency Micro Air dust collectors are engineered for powerful filtration at

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES 2237 MARSHALLTOWN BLVD. MARSHALLTOWN, IOWA 50158 PHONE: (641) 753-5601 TOLL FREE: 1-800-383-5601 FAX: (641) 752-9748 WWW.SPREAD-ALLMFG.NET OPERATING MANUAL centrifugal fan SAFETY PRACTICES 1. Have a qualified

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

PRODUCT FEATURES & BENEFITS

PRODUCT FEATURES & BENEFITS Product Features & Benefits PRODUCT FEATURES & BENEFITS 1105 Seam Welded Elbows: Seam welds add strength to the gores Seam welds eliminate meat hooks Easy to adjust FasFit Airtite Take Offs: Feature airtight

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

TOWN OF ARLINGTON. TOWN OF ARLINGTON P.O. Box 507 ARLINGTON, TENNESSEE 38002

TOWN OF ARLINGTON. TOWN OF ARLINGTON P.O. Box 507 ARLINGTON, TENNESSEE 38002 TOWN OF ARLINGTON TOWN OF ARLINGTON P.O. Box 507 ARLINGTON, TENNESSEE 38002 Mike Wissman, Mayor Cathy Durant, Town Administrator Brittney Owens, Town Recorder, CMFO REQUEST FOR PROPOSAL RFP # FY2018 DUE:

More information

DUST COLLECTORS. Stronger. Better. CLEANER.

DUST COLLECTORS. Stronger. Better. CLEANER. DUST COLLECTORS Stronger. Better. CLEANER. Stronger. Better. CLEANER. Micro Air FORCE Dust Collectors The Next Generation Of CLEAN Air Systems Unrivaled Cleaning Technology FORCE Dust Collectors are designed

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements SURGE LIMITING BULLETIN 485 APRIL, 2017 PB FANS Designed for high pressure, low flow applications with stringent job process requirements Capacities to 30,000 CFM Static pressures to 180 WG Temperatures

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

THE WORLD S FASTEST DUCTING

THE WORLD S FASTEST DUCTING NORDFAB DUCTING CATALOGUE Quick-Fit C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete

More information

No other jet/vac sewer cleaner can match this collection of no-extra-cost advantages VACALL.COM (800)

No other jet/vac sewer cleaner can match this collection of no-extra-cost advantages VACALL.COM (800) Standard advantages set AllJetVac models apart from brands that like to charge extra Setting new value and performance standards in sewer line maintenance Vacall AllJetVac combination jet/vac models introduce

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

2 Saudi Fan Industries

2 Saudi Fan Industries 1 2 3 4 5 6 7 The fan housing is constructed of heavy gauge Galvanized steel sheet with a rigid internal support structure the 8 Product Features design 9 Square Inline Centrifugal Fan ISQ 300 Performance

More information

Your Clean Air Source!

Your Clean Air Source! Forward Curve Your Clean Air Source! HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY Established in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial

More information