1 Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28

2 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with the industry s best performance and durability for general clean air, high grease and other contaminant applications (as found in restaurants, food service and fume hood exhaust). Both Roof Upblast and Sidewall configurations are specifically designed to discharge air directly away from the mounting surface. Broadest performance in the industry, up to 5 in. wg (1245 Pa) and 3, (51, ). Most advanced motor cooling of any fan in its class. Greenheck pioneered leakproof construction for the entire life of the fan utilizing a one-piece windband continuously welded to the curb cap. Performance as cataloged is assured. All fan sizes are tested in our AMCA Accredited Laboratory and all models are licensed to bear the AMCA Sound and Air performance seals. UL/cUL Listed for electrical and grease. Greenheck subjects these products to extensive life testing, assuring you the fans will provide many years of reliable performance. CUE, CUBE, CW, and CWB models are listed for electrical (UL/cUL 75) File no. E41 CUE, CUBE, CW, and CWB models are listed for grease removal (UL/cUL 762) File no. MH11745 Greenheck Corporation certifies that the s CUE, CUBE, CW and CWB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The certified ratings for s CUE, CUBE, CW, and CWB are shown on pages 8 to 69. *UL/cUL is optional and must be specified Quick Delivery and Quick Build Programs You can order from more than 4 Series C configurations, hundreds of in-stock ventilation products and accessories that can ship to your job site in less than 24 hours from our strategically located warehouses throughout the world. For other sizes and configurations where rapid response time is required, our Quick Build (QB) Program can manufacture and ship your custom products in one, three, five, or ten days. 2

3 Table of Contents Comparison...4 Product Features and Accessories Typical Installation Code CUE Performance and Dimensions CUBE Performance and Dimensions CW Performance and Dimensions CWB Performance and Dimensions Typical Specifications Warranty Outstanding Customer Service Your local Greenheck representative has a wealth of industry and product knowledge to answer your questions. Our representatives receive the latest product information and can have orders processed directly to our factory. With our direct order processing system, we can ship orders as fast as the next day. With Greenheck s experienced staff, we can answer questions and provide solutions. Leading Edge Technical Support When you need extensive product information look no further. Greenheck products are supported by the industry s best product literature, ranging from catalogs, installation, operation and maintenance manuals (IOM s), electronic media, computer aided product selection (CAPS) program and more. You ll also find this information on our website at Count on personal service and expertise from our national and international representative organizations. To locate your nearest Greenheck representative, call or visit our website at World Class Manufacturing Greenheck s skilled production workers use cost-effective machines and unique dies designed and built by our own engineers to add innovative features and greater strength to our centrifugal exhaust fans. Our advanced manufacturing processes and quality control procedures always ensure the highest product quality. And just to be sure you get the peace-of-mind you expect when you specify Greenheck, our assembly inspectors test run and monitor every fan before it leaves the factory. Results of these tests are kept in permanent records for future reference. 3

4 Comparison Standard s CUE & CW - Direct Drive Available in fourteen sizes with nominal wheel diameters ranging from 9 through 2 inches (229 through 58 millimeters). s CUE/CW 6 through 2 Capacities range from 7 to 6,4 (12 to 1,9 ) with static pressures to 2.25 in. wg (56 Pa). CUBE & CWB - Belt Drive Available in fourteen sizes with nominal wheel diameters ranging from 9 through 48 inches (229 through 1219 millimeters). s CUBE-98 through CUBE-48 Capacities range from 24 to 3, (4 to 51, ) with static pressures to 2 in. wg (498 Pa). s CWB-98 through CWB-3 Capacities range from 24 to 12,5 (4 to 21,2 ) with static pressures to 2 in. wg (498 Pa). High Pressure s CUE- & CW- - Direct Drive Available in three sizes with nominal wheel diameters ranging from 14 through 18 inches (356 through 457 millimeters). s CUE/CW-141, 161, and 18 Capacities range from 75 to 4,8 (1,3 to 8,2 ) with static pressures to 3 in. wg (747 Pa). CUBE- & CWB- - Belt Drive Available in nine sizes with nominal wheel diameters ranging from 1 through 36 inches (254 through 914 millimeters). s CUBE-11 through CUBE-36 Capacities range from 2 to 17, (34 to 28,9 ) with static pressures to 2.75 in. wg (685 Pa). s CWB-11 through CWB-3 Capacities range from 2 to 9, (34 to 15,3 ) with static pressures to 2.75 in. wg (685 Pa). Extended Pressure s CUBE-XP - Belt Drive Available in four sizes with nominal wheel diameters ranging from 14 through 36 inches (356 through 914 millimeters). s CUBE-161XP, 24XP, 3XP, and 36XP Capacities range from 65 to 1,7 (1,1 to 18,2 ) with static pressures to 5 in. wg (1,245 Pa). 4

5 Standard Construction Features Wheel - An aluminum, backward-inclined, non-overloading centrifugal wheel is utilized to generate high efficiency and minimal sound. Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is statically and dynamically balanced for long life and quiet operation. Disconnect Switch - NEMA-1 switch is factory mounted and wiring is provided from the motor as standard (other switches are available). All wiring and electrical components comply with the National Electric Codes (NEC) and are either UL/cUL Listed or Recognized. Shaft - Precisely sized, ground and polished so the first critical speed is at least 25% over the maximum operating speed. Where the shaft makes contact with bearings, close tolerances result in longer bearing life. Bearings - 1% factory tested and designed specifically for air handling applications with a minimum L 1 life in excess of 1, hours (L 5 life of 5, hours). - Carefully matched to the fan load and is mounted out of the airstream. Cover - Constructed of aluminum. Attached with stainless steel fasteners for easy removal and access to the motor compartment and drive assembly. Stainless Steel Fasteners - Allow easy removal and access to the motor compartment and drive assembly. Cooling - Cooling fins located on top of fan wheel draw outside air through a large breather tube directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life. Lifting Points - Select models have various lifting points located on the drive frame and bearing plates. Vibration Isolation - True vibration isolators contain two independent studs with rubber neoprene to support the drive assembly and wheel for long life and quiet operation. (No steel to steel contact.) Drive Assembly - Belts, pulleys and keys are oversized 15% of driven horsepower. Machined cast pulleys are adjustable for final system balancing. Belts are static free and oil resistant. Windband - One piece, heavy gauge aluminum with a rolled bead for extra strength directs exhaust air away from the mounting surface. Leakproof Construction - One-piece windband is continuously welded to the curb cap and drain trough for leakproof protection on models CUE and CUBE sizes 98 through 36 and all sizes with UL/cUL 762. Mounting Holes - Aluminum curb cap has prepunched mounting holes to ensure correct attachment to the roof. Drain Trough - Allows for one-point drainage of water, grease and other residues. (Roof Upblast only.) Galvanized Birdscreen - Rigid wire protects the fan discharge from birds and small objects. Standard on all sidewall fan models CW and CWB. Galvanized Mounting Plate - Allows mounting and sealing to the wall prior to mounting the entire unit. The remainder of the unit is attached to the mounting plate without locating and fastening problems associated with mounting a heavy sidewall unit to a wall. (Sidewall only.) Internal Conduit Chase - For easy internal electrical wiring in applications, not subject to NFPA. Nameplate - Permanent stamped aluminum nameplate for exact model and serial number identification. 5

6 Options and Accessories 6 Non-Stick Wheel - Patented coating helps prevent wheel imbalance in heavy grease applications and allows buildup on wheel to be easily removed. Patent No. 5,89,993 Coatings - Wide variety of coatings and colors are available for decorative to acidic applications. Clean-Out Port - Patented removable plug allows for easy spray or steam cleaning of wheel through the windband. (Roof Upblast only.) Patent No. 5,89,993 Birdscreen - Galvanized or aluminum rigid wire to protect the fan discharge from birds or small objects. (Galvanized is standard on Sidewall models.) Self-Draining Grease System - Drains grease and rain water back through the ductwork into the specially designed Greenheck kitchen hood. The grease and rain water is then channeled into the restaurant s floor grease trap. Curb Seal - Rubber seal between fan and curb to assure proper sealing when attached to a curb. Roof Curbs - Wide variety of roof curbs are available for mounting the fan to the roof, including: vented, flanged, pitched, and soundabsorbing. Vented Curb Extensions - Mounts between roof curb and roof mounted fan to meet NFPA requirements of 4 in. minimum discharge above the roof when mounted on a minimum 8 in. high roof curb. Disconnect Switches - Assorted NEMA rated switches are available for positive electrical shutoff and safety, including: dust-tight, rainproof, and corrosionresistant. Windband Extension - Aluminum tube raising the fan discharge an additional 36 in. for special code requirements. Dampers - Designed to prevent outside air from entering back into the building when fan is off. Includes backdraft and motorized dampers. (N/A with UL/cUL 762) Tie Down Points - Four brackets located on the windband for securing the fan in heavy wind applications. Drain Connection - Allows for single point drainage of grease, water or other residues. (Roof Upblast only.) Grease Trap - Aluminum trap designed to collect grease residue to avoid drainage onto roof surface. (Roof Upblast only.) Grease Trap with Absorbent Material - Same as above with an absorbent material to collect grease residue for easy disposal. (Roof Upblast only.) Speed Controllers - Available for use with shaded pole and permanent split capacitor open motors on direct drive fans. They provide an economical means of system balancing. Hinge Kit - Allows maintenance personnel to hinge the entire fan up to gain access to wheel and ductwork for regular inspection and cleaning. (Roof Upblast only.) Hinged Base - Allows for easy maintenance. Hinge and restraining cables are factory mounted to a subbase attached directly to curb without additional height added. (Roof Upblast only.) UL/cUL 75 - all Series C models are listed for electrical. File no. E41 UL/cUL all Series C models are listed for grease removal. File no. MH11745

7 Typical Installations 8 or 12 in. (23 to 35 mm) Roof Deck Typical Installation - General Clean Air or Fume Hood (Non Grease) Recommended Duct and Damper Size Recommended Roof Opening Factory Wired to Disconnect Series C exhaust fans are designed for applications ranging from clean air to contaminated air. A typical installation is shown. Sizes Wiring by 95 and Others Damper smaller can handle temperatures up to 13 F (54 C). Mounting Bolt Hole Circle Damper Recommended Wall Opening Recommended Duct and Damper Size Wiring by others Typical Installation - Commercial Kitchen (Grease) Wall Factory wired motor to disconnect 8 or 12 in. (23 to 35 mm) Roof Deck Wiring by Others Damper Recommended Duct and Damper Size Recommended Roof Opening Factory Wired to Disconnect Sizes 98 and larger are designed to meet restaurant and food service applications. These fans are UL/cUL Listed for grease removal and have been tested under high temperature (4 F (24 C)) and abnormal flare-up (6 F (316 C)) conditions. Due to high temperatures and grease-laden airstreams in commercial kitchen ventilation, system designers must be aware of governing codes and guidelines. The National Fire Protection Association (NFPA) is the primary source which governs many codes for commercial kitchen ventilation. Selected information from NFPA is shown below. Local code authorities should be consulted before proceeding with any kitchen ventilation project. Exhaust fans used in kitchen ventilation applications must have external wiring. (Wiring must not be installed in the airstream.) Installation must include a means for inspecting, cleaning and servicing the exhaust fan. (e.g. Hinged Curb Cap) No dampers are to be installed in the system. Minimum 4 in. Minimum 4 in. (116 mm) (116 mm) Discharge Height Discharge Height Grease Trap Minimum 8 in. (23 mm) Roof Deck Grease Trap Minimum 8 in. (23 mm) Roof Deck Welded Duct Welded Duct by others. by others. Minimum of Minimum of 18 in. ( 457 mm) 18 in. ( 457 mm) above roof deck per NFPA above roof deck per NFPA Recommended Recommended Roof Opening Roof Opening Vented Curb Extension NEMA 3R Disconnect NEMA 3R Disconnect factory wired from factory wired from motor to disconnect motor to disconnect through the breather through the breather tube (Optional) tube (Optional) Vented Curb Extension External Wiring External Wiring Liquid Tight Liquid Tight Flexible Conduit Flexible Conduit by Others by Others Mounting Bolt Hole Circle Recommended Roof Opening Welded Duct by Others Wall External Wiring Liquid Tight Flexible Conduit by Others Note: Above installations are recommendations based on national codes. The local authority may supercede these recommendations. Code The model number code is designed to completely identify the fan. The correct code letters must be specified to designate belt or direct drive and roof or wall mounted configurations. The remainder of the model number is determined by the size and performance. C UBE - 24 XP - 5 C - Series fan Configuration UBE - Belt Drive Roof Mounted UE - Direct Drive Roof Mounted WB - Belt Drive Wall Mounted W - Direct Drive Wall Mounted Size 6 through 48 Wheel Pressure Level - High Pressure (Belt Drive only) 4 = 1/4 1 = 1 3 = 3 3 = 1/3 15 = = 5 5 = 1/2 2 = 2 75 = = 3/4 (Direct Drive only) A = 1725 D = 155 B = 114 E = 15 C = 86 G = 13 XP - Extended High Pressure (Belt Drive Only) 7

8 CUE-6 and 65 - Direct Drive (467) 17 (432) Damper Size = 8 x 8 (23 x 23) Roof Opening = 11/2 x 11/2 (267 x 267) ^Approximate Unit Weight = 29 lb. (13 kg) 131/2 (343) (289) 13/4 (44) E 6-G 65-E 6-D 65-G 65-D Density.75 lb/ft CUE-6-E 1/2 15 CUE-6-G 1/1 13 CUE-6-D 1/6 155 CUE-65-E 1/1 15 CUE-65-G 1/6 13 CUE-65-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 8

9 CUE-7 and 75 - Direct Drive (467) 17 (432) 131/2 (343) (289) 13/4 (44) E 7-G 7-D 75-E 75-G 75-D Density.75 lb/ft 3 Damper Size = 8 x 8 (23 x 23) Roof Opening = 11/2 x 11/2 (267 x 267) ^Approximate Unit Weight = 29 lb. (13 kg) CUE-7-E 1/1 15 CUE-7-G 1/6 13 CUE-7-D 1/3 155 CUE-75-E 1/8 15 CUE-75-G 1/5 13 CUE-75-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 9

10 CUE-8 and 85 - Direct Drive 21 (533) 19 (483) Damper Size = 1 x 1 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 4 lb. (18 kg) (34) 111/2 (292) 13/4 (44) G 85-E 8-E 8-D 85-G 85-D Density.75 lb/ft CUE-8-E 1/4 15 CUE-8-G 1/3 13 CUE-8-D 1/2 155 CUE-85-E 1/4 15 CUE-85-G 1/3 13 CUE-85-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 1

11 CUE-9 and 95 - Direct Drive CUE-9 21 (533) /2 (34) (292) 13/4 (44) Density.75 lb/ft 3 19 (483) CUE (533) E 9-G 9-D 95-E 95-G 95-D (387) (34) (483) 13/4 (44) Damper Size = 1 x 1 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 4 lb. (18 kg) CUE-9-E 1/4 15 CUE-9-G 1/25 13 CUE-9-D 1/ CUE-95-E 1/3 15 CUE-95-G 1/12 13 CUE-95-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 11

12 CUE-98 and 11 - Direct Drive (632) 19 (483) * (718) (441) 13/4 (44) B 98-A 11-B 11-A Density.75 lb/ft 3 Damper Size = 12 x 12 (35x 35) Roof Opening = 141/2 x 141/2 (368 x 368) ^Approximate Unit Weight = 53 lb. (24 kg) C 98-C CUE-98-C 1/8 86 CUE-98-B 1/6 114 CUE-98-A 1/ CFM B MAXIMUM MOTOR FRAME SIZE = 56 Sones CFM B Sones CFM B Sones CUE-11-C 1/8 86 CUE-11-B 1/6 114 CUE-11-A 1/ CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 12

13 CUE-121 and Direct Drive 24 7 /8 (632) 19 (483) *281/4 (718) 17 3 /8 (441) 13/4 (44) A Density.75 lb/ft A Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) ^Approximate Unit Weight = 64 lb. (29 kg) C 121-B 131-C 131-B CUE-121-C 1/8 86 CUE-121-B 1/6 114 CUE-121-A 1/ CUE-131-C 1/8 86 CUE-131-B 1/6 114 CUE-131-A 3/ CFM B MAXIMUM MOTOR FRAME SIZE = 56 Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 13

14 CUE-141, 141, 161 and Direct Drive (733) Density.75 lb/ft 3 * (756) (492) 13/4 (44) B 141-A 161-B 161-A 141-A 22 (559) C 161-C 161-B 161-A Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) ^Approximate Unit Weight = 9 lb. (41 kg) CUE-141-C 1/8 86 CUE-141-B 1/4 114 CUE-141-A CUE-141-A 1/ CUE-161-C 1/4 86 CUE-161-B 1/2 114 CUE-161-A CUE-161-B 1/3 114 CUE-161-A 11/ CFM B MAXIMUM MOTOR FRAME SIZE = 145T Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 14

15 CUE-18, 18 and 2 - Direct Drive (95) 3 (762) * (524) 21 (533) 13/4 (44) Damper Size = 18 x 18 (457 x 457) Roof Opening = 21/2 x 21/2 (521 x 521) ^Approximate Unit Weight = 142 lb. (64 kg) C 18-B 18-A 2-C 2-B Density.75 lb/ft CUE-18-C 1/2 86 CUE-18-B CUE-18-A CUE-2-C 3/4 86 CUE-2-B CFM B MAXIMUM MOTOR FRAME SIZE = 184T Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 15

16 CUBE-98 - Belt Drive (632) 19 (483) Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) * (718) (441) 13/4 (44) /4 hp Density.75 lb/ft 3 CUBE / CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/399) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

17 CUBE-11 - Belt Drive (632) 19 (483) Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) * (718) (441) 13/4 (44) /4 hp /3 hp Density.75 lb/ft CUBE /4 CUBE / CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2591) 3 MAXIMUM = 182 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

18 CUBE-11 - Belt Drive (632) 19 (483) Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) * (718) (441) 13/4 (44) /3 hp 1/4 hp Density.75 lb/ft CUBE /4 CUBE /3 CUBE / CFM B.7.6 Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/3195) 3 MAXIMUM = 258 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

19 CUBE Belt Drive (632) 19 (483) Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 66 lb. (3 kg) * (718) (441) 13/4 (44) /4 hp 685 1/3 hp Density.75 lb/ft CUBE /4 CUBE /3 CUBE / CFM B.2.3 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2199) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

20 CUBE Belt Drive (632) (483) Damper Size = 12 x 12 (35 x 35) Roof Opening = 141/2 x 141/2 (368 x 368) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 66 lb. (3 kg) * (718) (441) 13/4 (44) /4 hp 65 1/3 hp Density.75 lb/ft /4 hp CUBE / CUBE / CUBE / CFM B.3.3 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/241) 3 MAXIMUM = 1645 TIP SPEED (ft/min.) = x 3.42 MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. 2

21 CUBE Belt Drive (733) 22 (559) Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 84 lb. (38 kg) * (756) (492) 13/4 (44) /4 hp 1/3 hp /4 hp hp Density.75 lb/ft CUBE / CFM B.4.4 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1726) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM CUBE /3 121 B Sones CFM B CUBE /2 Sones CFM B Sones CFM B CUBE /4 Sones CFM B Sones CFM CUBE B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

22 CUBE Belt Drive (733) 22 (559) Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 84 lb. (38 kg) * (756) (492) 13/4 (44) /3 hp 1/4 hp /4 hp Density.75 lb/ft CUBE / CUBE /3 165 CUBE /2 CUBE / CFM 331 B.6 Sones 6.1 CFM 566 B.1 Sones 6.7 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2285) 3 MAXIMUM = 211 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

23 CUBE Belt Drive (733) 22 (559) Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 87 lb. (39 kg) * (756) (492) 13/4 (44) /4 hp 1/3 hp 3/4 hp hp Density.75 lb/ft CUBE / CUBE /3 965 CUBE /2 CUBE /4 CUBE CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1365) 3 MAXIMUM = 139 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

24 CUBE Belt Drive (733) 22 (559) Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 87 lb. (39 kg) * (756) (492) 13/4 (44) /3 hp 1/4 hp 3/4 hp hp 151 Density.75 lb/ft CUBE / CUBE / CUBE /2 CUBE /4 CUBE CFM 889 B.12 Sones 7. CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/166) 3 MAXIMUM = 169 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

25 CUBE-161XP - Belt Drive (733) 22 (559) Damper Size = 16 x 16 (46 x 46) Roof Opening = 181/2 x 181/2 (47 x 47) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 87 lb. (39 kg) * (756) (492) 13/4 (44) /4 hp 1 hp Density.75 lb/ft 3 CUBE-161XP-5 1/2 CUBE-161XP-7 3/4 CUBE-161XP-1 1 CUBE-161XP-15 11/ CFM 968 B.34 Sones 1. CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/217) 3 MAXIMUM = 2525 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

26 CUBE-18 - Belt Drive (899) 3 (762) * (727) 21 (553) 13/4 (44) Damper Size = 18 x 18 (457 x 457) Roof Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 126 lb. (57 kg) /3 hp 1/4 hp 1 hp 3/4 hp DO NOT SELECT TO THE LEFT OF THE SYSTEM CURVE hp X 1 Density.75 lb/ft CUBE / CUBE /3 82 CUBE /2 94 CUBE / CUBE CUBE /2 CUBE CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1167) 3 MAXIMUM = 1495 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

27 CUBE-18 - Belt Drive (899) 3 (762) * (727) 21 (553) 13/4 (44) Damper Size = 18 x 18 (457 x 457) Roof Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 126 lb. (57 kg) /3 hp 1/4 hp 1 hp 3/4 hp hp Density.75 lb/ft 3 CUBE / CUBE /3 925 CUBE /2 165 CUBE / CUBE CUBE /2 CUBE CFM 157 B.22 Sones 8.3 CFM 1799 B.26 Sones 9.5 CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1315) 3 MAXIMUM = 1685 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

28 CUBE-2 - Belt Drive (899) 3 (762) * (727) 21 (553) 13/4 (44) Damper Size = 18 x 18 (457 x 457) Roof Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 142 lb. (64 kg) /3 hp 1/4 hp /4 hp 1 hp hp X Density.75 lb/ft 3 CUBE-2-4 1/ CUBE-2-3 1/3 665 CUBE-2-5 1/2 76 CUBE-2-7 3/ CUBE CUBE /2 CUBE CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/946) 3 MAXIMUM = 121 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

29 CUBE-2 - Belt Drive (899) 3 (762) * (727) 21 (553) 13/4 (44) Damper Size = 18 x 18 (457 x 457) Roof Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.4 (1.) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 142 lb. (64 kg) /4 hp 1-1 hp 2 hp 74 3 hp X 1 16 Density.75 lb/ft 3 CUBE-2-5 1/2 CUBE-2-7 3/ CUBE CUBE /2 CUBE CUBE CFM 224 B.31 Sones 8.1 CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/193) 3 MAXIMUM = 16 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

30 CUBE-22 - Belt Drive (186) 34 (864) * (86) 251/2 (648) 13/4 (44) Damper Size = 24 x 24 (61 x 61) Roof Opening = 261/2 x 261/2 (673 x 673) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 174 lb. (79 kg) /3 hp 1/4 hp 1 hp 3/4 hp hp Density.75 lb/ft X 1 CUBE / CUBE /3 52 CUBE /2 6 CUBE / CUBE CUBE /2 CUBE CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/743) 3 MAXIMUM = 955 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. 3

31 CUBE-22 - Belt Drive (186) 34 (864) * (86) 251/2 (648) 13/4 (44) Damper Size = 24 x 24 (61 x 61) Roof Opening = 261/2 x 261/2 (673 x 673) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 174 lb. (79 kg) hp 3/4 hp 2 hp hp Density.75 lb/ft X 1 CUBE /2 CUBE / CUBE CUBE /2 985 CUBE CUBE CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/847) 3 MAXIMUM = 124 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

32 CUBE-24 - Belt Drive (186) 34 (864) * (86) 251/2 (648) 13/4 (44) Damper Size = 24 x 24 (61 x 61) Roof Opening = 261/2 x 261/2 (673 x 673) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 175 lb. (79 kg) /3 hp 1/4 hp 3/4 hp 1 hp hp 1-72 X 1 82 Density.75 lb/ft 3 93 CUBE / CUBE /3 51 CUBE /2 585 CUBE / CUBE CUBE /2 CUBE CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/725) 3 MAXIMUM = 93 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

33 CUBE-24 - Belt Drive (186) 34 (864) * (86) 251/2 (648) 13/4 (44) Damper Size = 24 x 24 (61 x 61) Roof Opening = 261/2 x 261/2 (673 x 673) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 175 lb. (79 kg) hp 3/4 hp 1-2 hp hp Density.75 lb/ft X 1 CUBE /2 CUBE / CUBE CUBE /2 CUBE CUBE CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/837) 3 MAXIMUM = 123 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

34 CUBE-24XP - Belt Drive (186) 34 (864) * (86) 251/2 (648) 13/4 (44) Damper Size = 24 x 24 (61 x 61) Roof Opening = 261/2 x 261/2 (673 x 673) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 175 lb. (79 kg) hp 3/4 hp 2 hp 1-3 hp Density.75 lb/ft 3 CUBE-24XP-5 1/ CUBE-24XP-7 3/ CUBE-24XP-1 1 CUBE-24XP-15 11/ CUBE-24XP CUBE-24XP CFM B.4.34 Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1478) 3 MAXIMUM = 2165 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

35 CUBE-3 - Belt Drive 5 (127) 4 (116) *36 (914) 29 (737) 13/4 (44) Damper Size = 3 x 3 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Windband Thickness =.8 (2.) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 313 lb. (142 kg) /3 hp 1 hp 3/4 hp 1-2 hp 3 hp hp X 1 X Density.75 lb/ft 3 95 CUBE-3-3 1/ CUBE-3-5 1/2 42 CUBE-3-7 3/4 48 CUBE CUBE /2 65 CUBE CUBE CUBE CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/522) 3 MAXIMUM = 95 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/5.5 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

36 CUBE-3 - Belt Drive 5 (127) 4 (116) *36 (914) 29 (737) 13/4 (44) Damper Size = 3 x 3 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Windband Thickness =.8 (2.) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 313 lb. (142 kg) hp 3/4 hp hp 1-3 hp hp Density.75 lb/ft X X 1 CUBE-3-5 1/ CUBE-3-7 3/4 555 CUBE CUBE /2 7 CUBE CUBE CUBE CFM 3125 B.44 Sones 7.3 CFM 3639 B.52 Sones 7.9 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/62) 3 MAXIMUM = 145 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/5.5 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

37 CUBE-3XP - Belt Drive 5 (127) 4 (116) *36 (914) 29 (737) 13/4 (44) Damper Size = 3 x 3 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Windband Thickness =.8 (2.) Cover Thickness =.51 (1.3) Curb Cap Thickness =.64 (1.6) ^Approximate Unit Weight = 313 lb. (142 kg) hp 1-1 hp 3/4 hp 3 hp hp Density.75 lb/ft X 1 CUBE-3XP-7 3/ CUBE-3XP CUBE-3XP-15 11/ CUBE-3XP CUBE-3XP-3 3 CUBE-3XP CFM 1776 B.48 Sones 9.4 CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/972) 3 MAXIMUM = 169 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/5.5 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

38 CUBE-36 - Belt Drive (1489) 46 (1168) * (994) (746) 13/4 (44) Damper Size = 36 x 36 (914 x 914) Roof Opening = 381/2 x 381/2 (978 x 978) Windband Thickness =.8 (2.) Cover Thickness =.64 (1.6) Curb Cap Thickness =.8 (2.) ^Approximate Unit Weight = 44 lb. (2 kg) hp 3/4 hp 2 hp 1-3 hp hp 54 X 1 X 1 62 Density.75 lb/ft 3 69 CUBE / CUBE /4 365 CUBE CUBE /2 46 CUBE CUBE CUBE CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/396) 3 MAXIMUM = 69 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/7.25 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

39 CUBE-36 - Belt Drive (1489) 46 (1168) * (994) (746) 13/4 (44) Damper Size = 36 x 36 (914 x 914) Roof Opening = 381/2 x 381/2 (978 x 978) Windband Thickness =.8 (2.) Cover Thickness =.64 (1.6) Curb Cap Thickness =.8 (2.) ^Approximate Unit Weight = 44 lb. (2 kg) hp 1-1 hp 3 hp 5 hp X 1 X 1 78 Density.75 lb/ft CUBE CUBE /2 55 CUBE CUBE CUBE CUBE / CFM 647 B.9 Sones 9.6 CFM 73 B 1.3 Sones 1.8 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/434) 3 MAXIMUM = 865 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/7.25 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

40 CUBE-36XP - Belt Drive (1489) 46 (1168) * (994) (746) 13/4 (44) Damper Size = 36 x 36 (914 x 914) Roof Opening = 381/2 x 381/2 (978 x 978) Windband Thickness =.8 (2.) Cover Thickness =.64 (1.6) Curb Cap Thickness =.8 (2.) ^Approximate Unit Weight = 44 lb. (2 kg) hp 3 hp 1-1 hp 5 hp X X Density.75 lb/ft 3 CUBE-36XP CUBE-36XP-15 11/2 87 CUBE-36XP CUBE-36XP-3 3 CUBE-36XP-5 5 CUBE-36XP-75 71/ CFM 321 B.81 Sones 1.5 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/748) 3 MAXIMUM = 149 TIP SPEED (ft/min.) = x 7.69 MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/7.25 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. 4

41 CUBE-42 - Belt Drive (1661) (1321) * (1137) (895) 13/4 (44) Damper Size = 42 x 42 (167 x 167) Roof Opening = 441/2 x 441/2 (113 x 113) Windband Thickness =.8 (2.) Cover Thickness =.64 (1.6) Curb Cap Thickness =.1 (2.5) ^Approximate Unit Weight = 578 lb. (262 kg) hp 2 hp 1-1 hp 3/4 hp 22 5 hp X 1 X 1 52 Density.75 lb/ft 3 6 CUBE / CUBE /4 28 CUBE CUBE /2 35 CUBE CUBE CUBE CUBE / CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/33) 3 MAXIMUM = 6 TIP SPEED (ft/min.) = x 11.6 MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/8.99 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

42 CUBE-48 - Belt Drive (1884) 58 (1473) * (1222) 36 (914) 13/4 (44) Damper Size = 48 x 48 (1219 x 1219) Roof Opening = 51/2 x 51/2 (1283 x 1283) Windband Thickness =.8 (2.) Cover Thickness =.64 (1.6) Curb Cap Thickness =.1 (2.5) ^Approximate Unit Weight = 675 lb. (36 kg) hp 1-1 hp 3/4 hp 3 hp 18 5 hp Density.75 lb/ft 3 49 X X 1 CUBE / CUBE /4 225 CUBE CUBE /2 285 CUBE CUBE CUBE CUBE / CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/246) 3 MAXIMUM = 49 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/11.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

43 CW-6 and 65 - Direct Drive (343) Density.75 lb/ft 3 143/4 (375) 113/4 (298) (467) E 6-G 65-E 6-D 65-G 65-D Damper Size = 8 x 8 (23 x 23) Damper Frame Size = 1 x 1 (254 x 254) Wall Opening = 81/2 x 81/2 (216 x 216) ^Approximate Unit Weight = 26 lb. (12 kg) CW-6-E 1/2 15 CW-6-G 1/1 13 CW-6-D 1/ CFM B Sones CFM B Sones CFM B Sones CW-65-E 1/1 15 CW-65-G 1/6 13 CW-65-D 1/3 155 CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 43

44 CW-7 and 75 - Direct Drive (343) 12.5 Density.75 lb/ft /4 (375) 113/4 (298) (467) E 7-G 7-D 75-E 75-G 75-D 2.1 Damper Size = 8 x 8 (23 x 23) Damper Frame Size = 1 x 1 (254 x 254) Wall Opening = 81/2 x 81/2 (216 x 216) ^Approximate Unit Weight = 26 lb. (12 kg) CW-7-E 1/1 15 CW-7-G 1/6 13 CW-7-D 1/3 155 CW-75-E 1/8 15 CW-75-G 1/5 13 CW-75-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 44

45 CW-8 and 85 - Direct Drive (34) Density.75 lb/ft (454) 15 (381) 21 (533) G 85-E 8-E 8-D 85-G 85-D 2.1 Damper Size = 1 x 1 (254 x 254) Damper Frame Size = 12 x 12 (35 x 35) Wall Opening = 11/2 x 11/2 (267 x 267) ^Approximate Unit Weight = 4 lb. (18 kg) CW-8-E 1/4 15 CW-8-G 1/3 13 CW-8-D 1/2 155 CW-85-E 1/4 15 CW-85-G 1/3 13 CW-85-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 45

46 CW-9 and 95 - Direct Drive CW (34) (454) 15 (381) 21 (533) Density.75 lb/ft 3 CW (387) E 9-G 9-D 95-E 95-G 95-D (454) 15 (381) 21 (533) Damper Size = 1 x 1 (254 x 254) Damper Frame Size = 12 x 12 (35 x 35) Wall Opening = 11/2 x 11/2 (267 x 267) ^Approximate Unit Weight = 4 lb. (18 kg) CW-9-E 1/4 15 CW-9-G 1/25 13 CW-9-D 1/ CW-95-E 1/3 15 CW-95-G 1/12 13 CW-95-D 1/ CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 46

47 CW-98 and 11 - Direct Drive * (718) Density.75 lb/ft (52) (429) (632) A 98-B 11-A C 98-C 11-B Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 53 lb. (24 kg) CW-98-C 1/8 86 CW-98-B 1/6 114 CW-98-A 1/ CFM B MAXIMUM MOTOR FRAME SIZE = 56 Sones CFM B Sones CFM B Sones CW-11-C 1/8 86 CW-11-B 1/6 114 CW-11-A 1/ CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 47

48 CW-121 and Direct Drive * (718) Density.75 lb/ft (52) (429) (632) B 121-A C 131-C 131-A 131-B Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 53 lb. (24 kg) CW-121-C 1/8 86 CW-121-B 1/6 114 CW-121-A 1/ CFM B MAXIMUM MOTOR FRAME SIZE = 56 Sones CFM B Sones CFM B Sones CW-131-C 1/8 86 CW-131-B 1/6 114 CW-131-A 3/ CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 48

49 CW-141, 141, 161 and Direct Drive * (756) (562) (492) (733) B 141-A 161-B 161-A 141-A 161-B Density.75 lb/ft A Damper Size = 15 x 15 (381 x 381) Damper Frame Size = 17 x 17 (432 x 432) Wall Opening = 151/2 x 151/2 (394 x 394) ^Approximate Unit Weight = 9 lb. (41 kg) C 161-C CW-141-C 1/8 86 CW-141-B 1/4 114 CW-141-A CW-141-A 1/ CW-161-C 1/4 86 CW-161-B 1/2 114 CW-161-A CW-161-B 1/3 114 CW-161-A 11/ CFM B MAXIMUM MOTOR FRAME SIZE = 145T Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 49

50 CW-18, 18 and 2 - Direct Drive * (524) Density.75 lb/ft (75) 25 (635) (95) Damper Size = 17 x 17 (432 x 432) Damper Frame Size = 19 x 19 (483 x 483) Wall Opening = 171/2 x 171/2 (445 x 445) ^Approximate Unit Weight = 142 lb. (64 kg) C 18-B 18-A 2-C 2-B CW-18-C 1/2 86 CW-18-B CW-18-A CW-2-C 3/4 86 CW-2-B CFM B MAXIMUM MOTOR FRAME SIZE = 184T Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. 5

51 CWB-98 - Belt Drive * (718) (52) (429) (632) Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 58 lb. (26 kg) /4 hp Density.75 lb/ft 3 CWB / CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/399) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

52 CWB-11 - Belt Drive * (718) (52) (429) (632) Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 58 lb. (26 kg) /4 hp /3 hp Density.75 lb/ft CWB /4 CWB / CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2591) 3 MAXIMUM = 182 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 215T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

53 CWB-11 - Belt Drive * (718) (52) (429) (632) Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 58 lb. (26 kg) /3 hp 1/4 hp Density.75 lb/ft 3 CWB /4 CWB /3 CWB / CFM B.7.6 Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/3195) 3 MAXIMUM = 258 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

54 CWB Belt Drive * (718) (52) (429) (632) Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 66 lb. (3 kg) /4 hp 685 1/3 hp Density.75 lb/ft CWB /4 CWB /3 CWB / CFM B.2.3 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2199) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

55 CWB Belt Drive * (718) (52) (429) (632) Damper Size = 12 x 12 (35 x 35) Damper Frame Size = 14 x 14 (356 x 356) Wall Opening = 121/2 x 121/2 (318 x 318) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 66 lb. (3 kg) /4 hp 65 1/3 hp Density.75 lb/ft /4 hp CWB / CWB / CWB / CFM B.3.3 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/241) 3 MAXIMUM = 1645 TIP SPEED (ft/min.) = x 3.42 MAXIMUM MOTOR FRAME SIZE = 56 AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.28 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

56 CWB Belt Drive * (756) (562) (492) (733) Damper Size = 15 x 15 (381 x 381) Damper Frame Size = 17 x 17 (432 x 432) Wall Opening = 151/2 x 151/2 (394 x 394) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 84 lb. (38 kg) /4 hp 1/3 hp /4 hp hp Density.75 lb/ft CWB / CWB /3 121 CWB /2 CWB / CWB CFM B.4.4 Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1726) 3 MAXIMUM = 1725 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

57 CWB Belt Drive * (756) (562) (492) (733) Damper Size = 15 x 15 (381 x 381) Damper Frame Size = 17 x 17 (432 x 432) Wall Opening = 151/2 x 151/2 (394 x 394) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 84 lb. (38 kg) /3 hp 1/4 hp /4 hp Density.75 lb/ft 3 CWB / CWB /3 165 CWB /2 CWB / CFM 331 B.6 Sones 6.1 CFM 566 B.1 Sones 6.7 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/2285) 3 MAXIMUM = 211 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

58 CWB Belt Drive * (756) (562) (492) (733) Damper Size = 15 x 15 (381 x 381) Damper Frame Size = 17 x 17 (432 x 432) Wall Opening = 151/2 x 151/2 (394 x 394) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 87 lb. (39 kg) /4 hp 1/3 hp 3/4 hp hp Density.75 lb/ft CWB / CWB /3 965 CWB /2 CWB /4 CWB CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1365) 3 MAXIMUM = 139 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

59 CWB Belt Drive * (756) (562) (492) (733) Damper Size = 15 x 15 (381 x 381) Damper Frame Size = 17 x 17 (432 x 432) Wall Opening = 151/2 x 151/2 (394 x 394) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 85 lb. (39 kg) /3 hp 1/4 hp 3/4 hp hp 151 Density.75 lb/ft CWB / CWB / CWB /2 CWB /4 CWB CFM 889 B.12 Sones 7. CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/166) 3 MAXIMUM = 169 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 145T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/1.72 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

60 CWB-18 - Belt Drive * (727) (75) 25 (635) (899) Damper Size = 17 x 17 (432 x 432) Damper Frame Size = 19 x 19 (483 x 483) Wall Opening = 171/2 x 171/2 (445 x 445) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 126 lb. (57 kg) /3 hp 1/4 hp 1 hp 3/4 hp DO NOT SELECT TO THE LEFT OF THE SYSTEM CURVE hp X 1 Density.75 lb/ft CWB / CWB /3 82 CWB /2 94 CWB / CWB CWB /2 CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1167) 3 MAXIMUM = 1495 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 31. 6

61 CWB-18 - Belt Drive * (727) (75) 25 (635) (899) Damper Size = 17 x 17 (432 x 432) Damper Frame Size = 19 x 19 (483 x 483) Wall Opening = 171/2 x 171/2 (445 x 445) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 126 lb. (57 kg) /3 hp 1/4 hp 1 hp 3/4 hp hp Density.75 lb/ft 3 CWB / CWB /3 925 CWB /2 165 CWB / CWB CWB /2 CWB CFM 157 B.22 Sones 8.3 CFM 1799 B.26 Sones 9.5 CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/1315) 3 MAXIMUM = 1685 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

62 CWB-2 - Belt Drive * (727) (75) 25 (635) (899) Damper Size = 17 x 17 (432 x 432) Damper Frame Size = 19 x 19 (483 x 483) Wall Opening = 171/2 x 171/2 (445 x 445) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 142 lb. (64 kg) /3 hp 1/4 hp /4 hp 1 hp hp X Density.75 lb/ft 3 CWB-2-4 1/ CWB-2-3 1/3 665 CWB-2-5 1/2 76 CWB-2-7 3/ CWB CWB /2 CWB CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/946) 3 MAXIMUM = 121 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

63 CWB-2 - Belt Drive * (727) (75) 25 (635) (899) Damper Size = 17 x 17 (432 x 432) Damper Frame Size = 19 x 19 (483 x 483) Wall Opening = 171/2 x 171/2 (445 x 445) Windband Thickness =.51 (1.3) Cover Thickness =.4 (1.) ^Approximate Unit Weight = 142 lb. (64 kg) hp 3/4 hp 1-2 hp Density.75 lb/ft X 1 CWB-2-5 1/2 CWB-2-7 3/4 CWB CWB /2 CWB CFM 224 B.31 Sones 8.1 CFM B.4.41 Sones CFM B Sones MAXIMUM B AT A GIVEN = (/193) 3 MAXIMUM = 14 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/2.92 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

64 CWB-22 - Belt Drive * (86) (794) (721) (187) Damper Size = 2 x 2 (58 x 58) Damper Frame Size = 22 x 22 (559 x 559) Wall Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 174 lb. (79 kg) /3 hp 1/4 hp 1 hp 3/4 hp hp Density.75 lb/ft X 1 CWB / CWB /3 52 CWB /2 6 CWB / CWB CWB /2 CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/743) 3 MAXIMUM = 955 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

65 CWB-22 - Belt Drive * (86) (794) (721) (187) Damper Size = 2 x 2 (58 x 58) Damper Frame Size = 22 x 22 (559 x 559) Wall Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 174 lb. (79 kg) hp 3/4 hp 1-2 hp X Density.75 lb/ft 3 CWB /2 CWB /4 CWB CWB /2 CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/847) 3 MAXIMUM = 185 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

66 CWB-24 - Belt Drive * (86) (794) (721) (187) Damper Size = 2 x 2 (58 x 58) Damper Frame Size = 22 x 22 (559 x 559) Wall Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 175 lb. (79 kg) /3 hp 1/4 hp 3/4 hp 1 hp hp 1-72 X 1 82 Density.75 lb/ft 3 93 CWB / CWB /3 51 CWB /2 585 CWB /4 CWB CWB /2 845 CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/725) 3 MAXIMUM = 93 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

67 CWB-24 - Belt Drive * (86) (794) (721) (187) Damper Size = 2 x 2 (58 x 58) Damper Frame Size = 22 x 22 (559 x 559) Wall Opening = 21/2 x 21/2 (521 x 521) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 174 lb. (79 kg) hp 3/4 hp 1-2 hp X 1 98 Density.75 lb/ft 3 17 CWB /2 CWB /4 CWB CWB /2 CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/837) 3 MAXIMUM = 17 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 184T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/3.76 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

68 CWB-3 - Belt Drive *36 (914) (975) (91) 5 (127) Damper Size = 25 x 25 (635 x 635) Damper Frame Size = 27 x 27 (686 x 686) Wall Opening = 251/2 x 251/2 (648 x 648) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 313 lb. (142 kg) hp 3/4 hp 1/3 hp 1-2 hp hp 6 X 1 68 X Density.75 lb/ft 3 CWB-3-3 1/ CWB-3-5 1/2 42 CWB-3-7 3/4 48 CWB CWB /2 CWB CWB CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/522) 3 MAXIMUM = 765 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/5.5 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

69 CWB-3 - Belt Drive *36 (914) (975) (91) 5 (127) Damper Size = 25 x 25 (635 x 635) Damper Frame Size = 27 x 27 (686 x 686) Wall Opening = 251/2 x 251/2 (648 x 648) Windband Thickness =.64 (1.6) Cover Thickness =.51 (1.3) ^Approximate Unit Weight = 313 lb. (142 kg) /4 hp 1 hp 1-2 hp 3 hp X 1 X 1 8 Density.75 lb/ft CWB-3-5 1/ CWB-3-7 3/4 555 CWB CWB / CWB CWB CFM 3125 B.44 Sones 7.3 CFM 3639 B.52 Sones 7.9 CFM B Sones CFM B Sones CFM B Sones MAXIMUM B AT A GIVEN = (/62) 3 MAXIMUM = 885 TIP SPEED (ft/min.) = x MAXIMUM MOTOR FRAME SIZE = 213T AVERAGE DISCHARGE VELOCITY (FPM) = CFM/5.5 CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones CFM B Sones Performance certified is for installation type A: Free inlet, Free outlet. Power rating (B) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard

70 Typical Specifications Direct Drive Specifications Spun aluminum exhaust fans shall be upblast centrifugal direct drive type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan housing shall be constructed of heavy gauge aluminum with a rigid internal support structure. s shall be mounted out of the airstream on vibration isolators. Fresh air for motor cooling shall be drawn into the motor compartment free of discharge contaminants. s shall be readily accessible for maintenance. A disconnect switch shall be factory installed and wired from the fan motor to a junction box within the motor compartment. A conduit chase shall be provided through the curb cap to the motor compartment for ease of electrical wiring. All fans shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Each fan shall bear a permanently affixed manufacturer s engraved metal nameplate containing the model number and individual serial number for future identification. Specifier to select one of the following mounting configurations: Roof Mounted Upblast Exhaust s A leakproof fan housing shall be constructed with a one piece windband with an integral rolled bead for added strength. s shall be model CUE or CUE- as manufactured by Greenheck Corporation, Schofield, WI. Sidewall Mounted Exhaust s A leakproof fan housing shall be constructed with a one piece windband with an integral rolled bead for added strength. shall be provided with a mounting plate, which is to be attached and sealed to the wall prior to locating the entire unit. s shall be model CW or CW- as manufactured by Greenheck Corporation, Schofield, WI. Belt Drive Specifications Spun aluminum exhaust fans shall be centrifugal belt driven type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan housing shall be constructed of heavy gauge aluminum with a rigid internal support structure. The windband shall be welded to the one-piece curb cap and on all sizes with UL/cUL 762. s shall be heavy duty ball bearing type, carefully matched to the fan load, and furnished at the specified voltage, phase and enclosure. Drive frame assembly shall be constructed of heavy gauge steel. s and drives shall be mounted on vibration isolators, out of the airstream where no steel to steel contact between rotating components and the base shall occur. Fresh air for motor cooling shall be drawn into the motor compartment through a ten square inch tube free of discharge contaminants. s and drives shall be readily accessible for maintenance. 7

71 Typical Specifications Precision ground and polished fan shafts shall be mounted in permanently sealed, lubricated pillow block ball bearings. Bearings shall be selected for a minimum L 1 life in excess of 1, hours (L 5 life of 5, hours) at maximum cataloged operating speed. Drives shall be sized for a minimum of 15% of driven horsepower. Pulleys shall be of the cast type, keyed and securely attached to the wheel and motor shafts. pulleys shall be adjustable for final system balancing. A disconnect switch shall be factory installed and wired from the fan motor to a junction box installed within the motor compartment. A conduit chase shall be provided through the base to the motor compartment for ease of electrical wiring. All fans shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Each fan shall bear a permanently affixed manufacturer s engraved metal nameplate containing the model number and individual serial number for future identification. Specifier to select one of the following mounting configurations: Roof Mounted Upblast Exhaust s A leakproof fan housing shall be constructed with a one piece windband with an integral rolled bead for added strength and shall be joined to the curb cap with a continuously welded seam. s shall be model CUBE, CUBE-, or CUBE-XP as manufactured by Greenheck Corporation, Schofield, WI. Sidewall Mounted Exhaust s A leakproof fan housing shall be constructed with a one piece windband with an integral rolled bead for added strength. shall be provided with a mounting plate, which is attached and sealed to the wall prior to locating the entire unit. s shall be model CWB or CWB- as manufactured by Greenheck Corporation, Schofield, WI. Options and Accessories For Belt and Direct Drives UL/cUL Listed s shall be Listed by Underwriters Laboratory for UL/cUL 75 for all electrical components. s shall be Listed by Underwriters Laboratory for UL/cUL 762 for all electrical components and grease removal Curb Extensions Shall be mounted between roof curb and roof mounted fans to meet NFPA requirements of 4 inches minimum discharge above the roof when mounted on a minimum 8 inch high roof curb. Grease Containers Drain connection shall be constructed of aluminum and allow for single point drainage of grease, water or other residues. Grease trap shall include the drain connection and shall be constructed from aluminum. The unit shall collect grease and water from the fan and extract the grease from the water for ease of grease disposal. Easy Clean Options Hinge kit shall be constructed of heavy gauge aluminum hinges and shall include hold open cables for field installation. Non-stick wheel shall be constructed of aluminum with a non-stick coating similar to Teflon as manufactured by Dupont. Clean-Out Port shall have a hole on the outside of the windband and a grease repellent compression rubber fit, allowing access to entire wheel for cleaning. Windband Extension Shall be constructed from heavy gauge aluminum tube that raises the discharge an additional 36 inches. 71

72 Page header Additional Exhaust Solutions s CUE, CUBE, CW, and CWB, Series C, are commonly used for general clean air, mild grease, and fume hood exhaust applications. Both Roof Upblast and Sidewall configurations are specifically designed to discharge air directly away from the mounting surface. These models are constructed of aluminum and use an aluminum backward inclined wheel. They are UL/cUL Listed for electrical or grease. Performance ranges up to 5 in. wg (1245 Pa) and up to 3, (51, ). USGF is ideal for heavy grease exhaust applications as found in char broilers, solid fuel cooking, and oriental cooking. Sizes range from 14 to 2. All are UL Listed for electrical and grease applications and are capable of exhausting 4 F (24 C) continuously. The unit is constructed entirely of steel and includes the non-stick coated steel wheel, NEMA-3R disconnect, hinged curb cap, and clean-out port. Performance ranges up to 3.25 in. wg (81 Pa) and up to 6,8 (11,6 ). SWB centrifugal backward inclined belt driven utility fans are designed for supply, exhaust and return air applications requiring higher discharge velocities and high static pressures. The SWB Series 1 is for general clean air applications. The SWB Series 2 fans are constructed with heavy gauge steel. Designed for light industrial duty and grease applications, it s capacities range up to 27, (45,9 ) and up to 5 in. wg (1245 Pa) of static pressure. SWB fans can be mounted indoors or outdoors. TCB inline belt driven fans are the ideal choice for installations with straight-through airflow in ducted systems. The wheels used are designed to provide higher efficiencies and lower sound levels. The fan itself can be mounted horizontally or vertically. Performance ranges up to 24, (4,8 ) and up to 4.5 in. wg (112 Pa) of static pressure. Building Value in Air Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative airrelated equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet dependable operation they experience long after the construction project ends. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. s are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Prepared to Support Green Building Efforts Catalog Rev. # Month Year Copyright 27 Greenheck Corp. P.O. Box 41 Schofield, WI Phone (715) greenheck.com Catalog Series C Rev. 7 April 28 IP Copyright 28 Greenheck Corp.

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

EcoWatt Products. Advancing Ventilation

EcoWatt Products. Advancing Ventilation EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER Model Features Exhaust air up to 6,817 CFM in high static pressure applications up to 3 Belt drives permit easy performance adjustments when needed Nonoverloading backward inclined wheel for efficiency

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

MIN/MAX PERFORMANCE IN INCHES WG

MIN/MAX PERFORMANCE IN INCHES WG Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators Direct-drive upblast ventilators are designed for continuous operation to exhaust foul air, smoke, fumes, odors and grease-laden vapors from range

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2. BDU Belt Drive - Centrifugal Up-Blast Fans W HT F Grease Drain B R RO Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Roof & Sidewall Mounted

Roof & Sidewall Mounted G, G Roof & Sidewall Mounted 4 E40001 - G and G UL/cUL Power Ventilators for Smoke ontrol Systems MH11711 - G UL/cUL Listed 705 is standard on In Stock models G and G are M Licensed for Sound and ir Performance

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

FKUB Belt Drive - Centrifugal Up-Blast Fans

FKUB Belt Drive - Centrifugal Up-Blast Fans FKUB Belt rive - Centrifugal Up-Blast Fans W HT F Grease rain B R RO C Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather

More information

Mixed Flow Inline Fan Model EQB

Mixed Flow Inline Fan Model EQB Mixed Flow Inline Fan Model EQB Belt Drive High efficiency lower cost May 2014 Model EQB Mixed Flow Inline Fan EQB mixed flow inline fans are designed to efficiently exhaust, supply, or recirculate general

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 APRIL 08 ROOF & WALL EXHAUSTERS

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

Greenheck Quick Delivery

Greenheck Quick Delivery Greenheck Quick Delivery Greenheck Quick Delivery Stock & Quick uild Catalog Volume 25 Stock & Quick uild Catalog This catalog is being sent to you on behalf of: Volume 25 Roof & Sidewall Mounted G and

More information

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17 Upblast Roof Exhauster Technical Specifications BULLETIN FX17 TABLE OF CONTENTS Introduction 3 Direct Drive Dimensional & Performance Data 4 Enhanced Direct Drive Dimensional & Performance Data 8 Belt

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

High Performance Axial Fans

High Performance Axial Fans High Performance Axial Fans Model AX High Efficiencies Low Sound July 2014 High Performance Axial Fans Greenheck s High Performance Axials, Model AX, are direct driven axials designed for inline air ventilation

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Mancoolers Models MCY, MCB, MCP

Mancoolers Models MCY, MCB, MCP Mancoolers s MCY, MCB, MCP October 2007 Mancoolers Greenheck MC Mancooler fans are direct drive, tube axial fans designed for applications where localized air direction and circulation are required. Mancoolers

More information

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS UPBLAST PROPELLER FANS Model LUBK SECTION 16 MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS Application Model LUBK is a high capacity roof mounted exhauster rated from 3,560 to 42,000 CFM. It

More information

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 February 207 ROOF & WALL EXHAUSTERS Overview Roof & Wall Exhausters Twin

More information

Downblast Centrifugal Fans with ECM

Downblast Centrifugal Fans with ECM Downblast Centrifugal Fans with ECM Model ered Featuring Electronically Commutated Motors GC_eRED_0512 May 2012 1 Motor Up to 90% efficient, electronically commutated motor (ECM) DOWNBLAST CENTRIFUGAL

More information

CONSTRUCTION FEATURES AND OPTIONS

CONSTRUCTION FEATURES AND OPTIONS MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MODL TX either ducted or nonducted applications. Its roof or sidewall mounting options permit location near the area to be and buildings. Typical applications include restaurant hoods and similar your

More information

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive Centrifugal Inline s Models SQ and BSQ Direct and Belt Drive May 21 Models SQ and BSQ Centrifugal Square Inline Duct s Table of Contents Standard Construction Features...4-5 Vari-Green Motor & Control

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

2 Saudi Fan Industries

2 Saudi Fan Industries 1 2 3 4 5 6 7 The fan housing is constructed of heavy gauge Galvanized steel sheet with a rigid internal support structure the 8 Product Features design 9 Square Inline Centrifugal Fan ISQ 300 Performance

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Advancing Ventilation

Advancing Ventilation Centrifugal oof Sidewall LPD CWD STXD STXDe SDBD SDBDe SDB STXB Direct Drive Belt Drive Centrifugal oof Sidewall Fans Advancing Ventilation centrifugal-roof--sidewall-0219 February 2019 MODEL LPD LOW POFILE

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined

More information

Centrifugal Roof Downblast Exhaust Fans

Centrifugal Roof Downblast Exhaust Fans Centrifugal Roof Downblast Exhaust Fans Models G and GB General Clean Air Light Contaminants Seismic High Wind Variable Volume Performance data now included. March 201 Models G and GB Spun Aluminum Downblast

More information

Power Roof and Wall Ventilators

Power Roof and Wall Ventilators Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 6 years, Loren Cook Company believes in superior quality and phenomenal service.

More information

Centrifugal Utility Fans

Centrifugal Utility Fans Centrifugal Utility Fans Model SFD, SFB, SWD and SWB Direct and Belt Drive Model SWD with November 7 Models SFD, SFB, SWD and SWB Utility Fans Centrifugal Utility Blowers are suitable for light duty applications

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

LINEA Low Discharge Roof Exhausters

LINEA Low Discharge Roof Exhausters LINEA Low Discharge Roof Exhausters TECHNICAL SPECIFICATIONS BULLETIN LF18 PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION

More information

Centrifugal Roof Downblast Exhaust Fans

Centrifugal Roof Downblast Exhaust Fans Centrifugal Roof Downblast Exhaust Fans General Clean Air Light Contaminants Seismic High Wind Variable Volume Models G and GB Performance data now included. March 201 Models G and GB Spun Aluminum Downblast

More information

Centrifugal Upblast Roof Exhausters, EVU-Series

Centrifugal Upblast Roof Exhausters, EVU-Series Centrifugal Upblast Roof Exhausters, EVU-Series TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 8 Motor Availability 10 Direct Drive Dimensional

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

Quickship Program Quick Delivery Wide Product Selection Competitive Price

Quickship Program Quick Delivery Wide Product Selection Competitive Price Quickship Program Quick Delivery Wide Product Selection Competitive Price Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS WPD WPB

TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS WPD WPB TURNING AIR INTO SOLUTIONS. PROPLLR WALL S WPD WPB CATALOG 48 March 7 PROPLLR WALL S Overview WPB WPD Twin City Fan & Blower Model WPD Medium Duty and Model WPB Light and Medium Duty Propeller Wall Fans

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PROPELLER WALL FANS WPD WPB CATALOG 4820 MARCH 2017

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PROPELLER WALL FANS WPD WPB   CATALOG 4820 MARCH 2017 Twin City Fan INDUSTRIAL PROCSS AND COMMRCIAL VNTILATION SYSTMS PROPLLR WALL S WPD WPB CATALOG 48 MARCH 7 PROPLLR WALL S Overview WPB WPD Twin City Fan & Blower Model WPD Medium Duty and Model WPB Light