MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER
|
|
- Oscar Weaver
- 5 years ago
- Views:
Transcription
1 L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting lugs (4) 9.00 Notes:... F. Heater Dimensions MBH D E F Intake hood and vent cap ship loose. Access doors typical on both sides. Refer to SD-IFG-INFO for CFM ranges, filter sizes, weights, curb cap sizes, discharge openings, and a bottom view. 4. Refer to SD-IFG-CC for units a cooling coil. 5. Refer to SD-IFG-EVAP for units an evaporative cooler. 6. Refer to SD-IFG-CURB for curb dimensions and options. 7. Gas inlet size: /" NPT for 00 MBH heaters and below; all others /4" NPT. 8. Temperature rise: 0 degree minimum, 90 degree maximum. 9. Dimensions "W" and "H" are the width and height of the entire unit except for the heater where "D" is the width and the height is 9" plus "E". 0. Power vented units do not have a vent cap; Dim. E = 0.. Dimension "F" is the recommended clearance to service the burner drawer. H Housing H Housing H Housing Gravity Power H Housing Flat filters in the intake hood H Housing V-bank filters, no intake hood Down Gravity * Optional intake damper adds 8" to the L length. End Power Model Housing Heater Sizes A B C L L L * L L L * H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. H W IFG-09 IFG-0 # 00, 50, 00, IFG-0 IFG- # 00, 50, IFG-09 # IFG-0 Wide 00, 50, IFG-8 IFG-0 # 00, 50, Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES BENDING METAL SCULPTING AIR Elkhart Lake, WI 500 Phone: (90) Fax: (90)
2 Qty. Model CFM S.P. BHP RPM HP Volts Ph. BTU (Input/Output) Tag General Construction Housing Galvanized steel " fiberglass insulation Weatherproof construction Large access panels Housing Options c Painted housing - machinery grey c Painted housing - special color: c Double wall insulation c Foil faced insulation c Hinged access doors Blower Section Forward curved, DWDI blower Precision machined steel shaft Blower wheels statically and dynamically balanced Adjustable V-belt drives Pulleys and belts selected for not less than 65% of driven HP Fan and motor mounted on vibration isolators Self-aligning pre-lubricated bearings EPACT rated motor c ODP (standard) c TEFC c VFD c Other Electrical Unit is field wired (standard) Optional c Disconnect switch only (mounted and wired to motor) NEMA NEMAR c Motor control center disconnect switch, one motor starter, fuse blocks and control transformer; single point wiring. c Extra motor starters: c Other Heater Section AGA and CGA certified heater Indirect fired gas burner Inlet gas pressure c Natural gas (standard) (ins/lbs) c Propane fuel (ins/lbs) 80% combustion efficiency Venting c Gravity vented (standard) c Power vented Heat exchanger c 409 SS (standard) c SS c Aluminized steel Burners c Aluminized steel (standard) c 409 SS Gas valve c One stage gas valve ductstat room stat c Two stage gas valve ductstat room stat c Mechanical modulating ductstat c Electronic modulating ductstat ductstat and room override stat room stat DDC controls by others c Other High temperature limit switch Gas pressure regulator Electric spark intermittent pilot All components UL recognized and wired to terminal strip Optional Accessories Damper Options c Motorized intake damper (mounted) c Motorized discharge damper (field installed) c End switch on damper c Return air (requires drawing from factory) Curb Options Height c Modular curb and rail (Arrangement A) c Roof curb and rail (Arrangement A) c Two support rails (Arrangement A) c Full perimeter curb (Arrangement A4) Filter Options Thickness c Aluminum cleanable c Fiberglass throw-away not available c 0% efficient pleated } H Housing c Other Cooling Options (requires drawing from factory) c Chilled water c Dx direct expansion c Evaporative Other Options c Remote control panel Enclosure - surface mounted c NEMA plastic enclosure (standard) c Metal enclosure (NEMA rating: ) -Position switches Indicator lights c Alarm c Filter c Other -Position switches c Heat-Off-Cool c Summer-Off-Winter c Fan-Off-Auto c Other c Mild weather thermostat (inlet air sensor) c Low temperature limit (freezestat) c Clogged filter switch c Gas pressure safety switch (high, low or both) c Convenience outlet (5V service receptacle) c High gas pressure regulator c Time clock c Occupied/Unoccupied (Night setback) c diffuser (-way or 4-way) c Elevation (over,000 ): c Other Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES Elkhart Lake, WI 500 Phone: (90) Fax: (90)
3 L (Housing Arr. H) 4" 5" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood E Gas connections Lifting lugs (4). H Housing Flat filters in the intake hood 9.00 F Heater Dimensions MBH D E F H Housing H Housing H Housing H Housing V-bank filters, no intake hood * Optional intake damper adds 8" to the L length. Notes:. Intake hood and vent caps ship loose.. Access doors typical on both sides.. Refer to SD-IFG-INFO for CFM ranges, filter sizes, weights, curb cap sizes, discharge openings, and a bottom view. 4. Refer to SD-IFG-CC for units a cooling coil. 5. Refer to SD-IFG-EVAP for units an evaporative cooler. 6. Refer to SD-IFG-CURB for curb dimensions and options. 7. Gas inlet size: /4" NPT. 8. Temperature rise: 40 degree minimum, 0 degree maximum. 9. Dimensions "W" and "H" are the width and height of the entire unit except for the heater where "D" is the width and the height is 9" plus "E". 0.. Power vented units do not have a vent cap; Dim. E = 0. Dimension "F" is the recommended clearance to service the burner drawer. Gravity Power Down Gravity End Power Model Housing Heater Sizes A B C L L L * L L L * H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. H W IFG- # 500, IFG-09 # IFG-0 Wide 600, 700, IFG-8 IFG-0 # 600, 700, Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES BENDING METAL SCULPTING AIR Elkhart Lake, WI 500 Phone: (90) Fax: (90)
4 Qty. Model CFM S.P. BHP RPM HP Volts Ph. BTU (Input/Output) Tag General Construction Optional Accessories Housing Galvanized steel " fiberglass insulation Weatherproof construction Large access panels Housing Options c Painted housing - machinery grey c Painted housing - special color: c Double wall insulation c Foil faced insulation c Hinged access doors Blower Section Forward curved, DWDI blower Precision machined steel shaft Blower wheels statically and dynamically balanced Adjustable V-belt drives Pulleys and belts selected for not less than 65% of driven HP Fan and motor mounted on vibration isolators Self-aligning pre-lubricated bearings EPACT rated motor c ODP (standard) c TEFC c VFD c Other Electrical Unit is field wired (standard) Optional c Disconnect switch only (mounted and wired to motor) NEMA NEMAR c Motor control center disconnect switch, one motor starter, fuse blocks and control transformer; single point wiring. c Extra motor starters: c Other Heater Section AGA and CGA certified heater Indirect fired gas burner Inlet gas pressure c Natural gas (standard) (ins/lbs) c Propane fuel (ins/lbs) 80% combustion efficiency Venting c Gravity vented (standard) c Power vented Heat exchanger c 409 SS (standard) c SS c Aluminized steel Burners c Aluminized steel (standard) c 409 SS Gas valve c Two stage gas valve ductstat room stat c Three stage gas valve ductstat room stat c Four stage gas valve ductstat room stat c Mechanical modulating ductstat c Electronic modulating ductstat ductstat and room override stat room stat DDC controls by others c Other High temperature limit switch Gas pressure regulator Electric spark intermittent pilot All components UL recognized and wired to terminal strip Damper Options c Motorized intake damper (mounted) c Motorized discharge damper (field installed) c End switch on damper c Return air (requires drawing from factory) Curb Options Height c Modular curb and rail (Arrangement A) c Roof curb and rail (Arrangement A) c Two support rails (Arrangement A) c Full perimeter curb (Arrangement A4) Filter Options Thickness c Aluminum cleanable c Fiberglass throw-away not available c 0% efficient pleated } H Housing c Other Cooling Options (requires drawing from factory) c Chilled water c Dx direct expansion c Evaporative Other Options c Remote control panel Enclosure - surface mounted c NEMA plastic enclosure (standard) c Metal enclosure (NEMA rating: ) -Position switches Indicator lights c Alarm c Filter c Other -Position switches c Heat-Off-Cool c Summer-Off-Winter c Fan-Off-Auto c Other c Mild weather thermostat (inlet air sensor) c Low temperature limit (freezestat) c Clogged filter switch c Gas pressure safety switch (high, low or both) c Convenience outlet (5V service receptacle) c High gas pressure regulator c Time clock c Occupied/Unoccupied (Night setback) c diffuser (-way or 4-way) c Elevation (over,000 ): c Other Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES Elkhart Lake, WI 500 Phone: (90) Fax: (90)
5 L (Housing Arr. H) 4" 78" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap E D Electrical connection H Housing V-bank filters intake hood Gas connections. Lifting lugs (4) 9.00 F Heater Dimensions MBH D E F H Housing H Housing H Housing H Housing Flat filters in the intake hood H Housing V-bank filters, no intake hood * Optional intake damper adds 8" to the L length. Notes:. Intake hood and vent caps ship loose.. Access doors typical on both sides.. Refer to SD-IFG-INFO for CFM ranges, filter sizes, weights, curb cap sizes, discharge openings, and a bottom view. 4. Refer to SD-IFG-CC for units a cooling coil. 5. Refer to SD-IFG-EVAP for units an evaporative cooler. 6. Refer to SD-IFG-CURB for curb dimensions and options. 7. Gas inlet size: /4" NPT. 8. Temperature rise: 60 degree minimum, 80 degree maximum. 9. Dimensions "W" and "H" are the width and height of the entire unit except for the heater where "D" is the width and the height is 9" plus "E". 0. Power vented units do not have a vent cap; Dim. E = 0.. Dimension "F" is the recommended clearance to service the burner drawer. Gravity Power Down Gravity End Power L L L * L L L * Model Housing Heater Sizes A B C H W H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. H Hsg. IFG-8 # 900, 050, IFG-0 Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES BENDING METAL SCULPTING AIR Elkhart Lake, WI 500 Phone: (90) Fax: (90)
6 Qty. Model CFM S.P. BHP RPM HP Volts Ph. BTU (Input/Output) Tag General Construction Optional Accessories Housing Galvanized steel " fiberglass insulation Weatherproof construction Large access panels Housing Options c Painted housing - machinery grey c Painted housing - special color: c Double wall insulation c Foil faced insulation c Hinged access doors Blower Section Forward curved, DWDI blower Precision machined steel shaft Blower wheels statically and dynamically balanced Adjustable V-belt drives Pulleys and belts selected for not less than 65% of driven HP Fan and motor mounted on vibration isolators Self-aligning pre-lubricated bearings EPACT rated motor c ODP (standard) c TEFC c VFD c Other Electrical Unit is field wired (standard) Optional c Disconnect switch only (mounted and wired to motor) NEMA NEMAR c Motor control center disconnect switch, one motor starter, fuse blocks and control transformer; single point wiring. c Extra motor starters: c Other Heater Section AGA and CGA certified heater Indirect fired gas burner Inlet gas pressure c Natural gas (standard) (ins/lbs) c Propane fuel (ins/lbs) 80% combustion efficiency Venting c Gravity vented (standard) c Power vented Heat exchanger Burners c 409 SS (standard) c SS c Aluminized steel c Aluminized steel (standard) c 409 SS Gas valve c Three stage gas valve ductstat room stat c Four stage gas valve ductstat room stat c Six stage gas valve ductstat room stat c Mechanical modulating ductstat c Electronic modulating ductstat ductstat and room override stat room stat DDC controls by others c Other High temperature limit switch Gas pressure regulator Electric spark intermittent pilot All components UL recognized and wired to terminal strip Damper Options c Motorized intake damper (mounted) c Motorized discharge damper (field installed) c End switch on damper c Return air (requires drawing from factory) Curb Options Height c Modular curb and rail (Arrangement A) c Roof curb and rail (Arrangement A) c Two support rails (Arrangement A) c Full perimeter curb (Arrangement A4) Filter Options Thickness c Aluminum cleanable c Fiberglass throw-away not available c 0% efficient pleated } H Housing c Other Cooling Options (requires drawing from factory) c Chilled water c Dx direct expansion c Evaporative Other Options c Remote control panel Enclosure - surface mounted c NEMA plastic enclosure (standard) c Metal enclosure (NEMA rating: ) -Position switches Indicator lights c Alarm c Filter c Other -Position switches c Heat-Off-Cool c Summer-Off-Winter c Fan-Off-Auto c Other c Mild weather thermostat (inlet air sensor) c Low temperature limit (freezestat) c Clogged filter switch c Gas pressure safety switch (high, low or both) c Convenience outlet (5V service receptacle) c High gas pressure regulator c Time clock c Occupied/Unoccupied (Night setback) c diffuser (-way or 4-way) c Elevation (over,000 ): c Other Architect Dwg. No. SD-IFG- Contractor Date 05/6 KEES Elkhart Lake, WI 500 Phone: (90) Fax: (90)
7 CFM Information MODEL IFG GENERAL INFORMATION Maximum CFM, Size and Area Blower CFM Limits Dx or Chilled Evaporative Model Housing Size Minimum Maximum Water Coil Cooler IFG-09-SM # 800,600,00,700 Heater Size CFM Limits IFG-09,000,600 " x " 4" x 9" (MBH) Minimum Maximum IFG-0,00, Sqft. 4.9 Sqft ,500 IFG-0 #,600,600,700 4,00 50,00,600 IFG-,800 5,000 7" x 9" 0" x 7" 00,600 7,000,000 7, Sqft. 7.8 Sqft. 50,000 7,000 IFG-09-SM #,400,00 4,800 5,600 00,400,000 IFG-09 Wide,400 5,00 7" x 50" 0" x 49" 50,800,000 IFG-0,000 7, Sqft. 0. Sqft. 400,00 4,000 #,400 7,000 7,00 8,00 500,000 7,000 IFG-8 4,000 0,000 4" x 50" 44" x 49" 600, 900,700,000 IFG-0 5,000, Sqft. 4.9 Sqft. 700, 050 4,500,000 IFG-0-HD 5,000 4, , 00 5,000 4,000 Filter Information V-bank Filters Filters in Intake Hood Special Filters* Quantity/ Quantity/ Quantity/ Model Housing Size Area 500 FPM Area 500 FPM Area 500 FPM IFG-09-SM # (4) 6" x 0" 4,400 () 6" x 5",800 () 6" x 0",00 IFG Sqft. 5.6 Sqft. 4.4 Sqft. IFG-0 IFG-0 # (6) 0" x 0" 8,00 (4) 0" x 0" 5,600 () 0" x 4",00 IFG- 6.7 Sqft.. Sqft. 6.6 Sqft. IFG-09-SM # (6) 6" x 0" 0,800 (4) 0" x 5" 6,900 () 4" x 4" 4,000 IFG-09 Wide () 0" x 0".9 Sqft. 8.0 Sqft. IFG-0.7 Sqft. # (8) 6" x 0" 4,400 (6) 0" x 5" 0,400 (4) 0" x 4" 6,700 IFG-8 (4) 0" x 0" 0.8 Sqft.. Sqft. IFG Sqft. IFG-0-HD * Examples of special filters would include 6" and " deep high efficiency filters. These would be located in a flat bank in the standard filter section. Weight Information Delete Full Housing Housing Arrangement Downturn Intake Modular Perimeter Heater Model Size H H H Plenum Damper Curb & Rail Curb Size IFG-09-SM # 550# 470# 480# (90#) 50# 70# 0# IFG # 480# 490# IFG-0 580# 500# 50# IFG-0 # 690# 600# 590# (0#) 60# 90# 40# IFG- 700# 60# 600# 740# 650# 640# IFG-09-SM # 990# 890# 80# (60#) 65# 0# 50# IFG-09 Wide,00# 90# 80# IFG-0,050# 950# 870# #,60#,060# 980# (60#) 70# 0# 60# IFG-8,00#,00#,00# IFG-0,00#,00#,0# IFG-0-HD,0#,0#,40# Note: The weight of the heater must be added to one of the housing arrangement weights to obtain the total weight of the unit. Weight 00 0# 50 50# 00 00# 50 0# 00 80# 50 40# # # # # # 900,40# 050,0# 00,80# Architect Dwg. No. SD-IFG-INFO Contractor Date / KEES Elkhart Lake, WI 500 Phone: (90) Fax: (90)
8 MODEL IFG GENERAL INFORMATION Down discharge H,H Housing H Housing Housing Arrangement Arrangement Opening Model Size A B C C D E F IFG-09-SM IFG-09 IFG-0 IFG-0 IFG- IFG-09-SM IFG-09 IFG-0 IFG-8 IFG-0 IFG-0-HD # # # Wide # NA NA NA NA NA NA One Two Three One Two Three Number of Furnaces Number of Furnaces NA NA Dim. F is from the inside of the curb cap. End discharge H,H Housing H Housing Housing Arrangement Arrangement Opening Model Size A C C D F IFG-09-SM IFG-09 IFG-0 IFG-0 IFG- IFG-09-SM IFG-09 IFG-0 IFG-8 IFG-0 IFG-0-HD #.00 # Wide NA NA # NA NA # NA One Two Three One Two Three Dim. F is from the Number of Furnaces Number of Furnaces bottom of the unit. NA NA NA Heater Dim. Size "E" Note: All of the dimensions are measured to the inside of the base rail / curb cap. Undersize the O.D. of the curb by ". Dimension B is the curb cap measurement for Curb Arrangements A and A where the curb is under the blower section only. Dimension C is the curb cap measurement for Curb Arrangement A4 where the curb is around the full perimeter of the unit. The first dimension C listed is for Housing Arrangements H and H that have the V-bank filter section. The second dimension C is for Housing Arrangement H. It is smaller since the V-bank filter section is replaced by flat filters in the intake section. Note: The views shown above are of Housing Arrangement H.
Air Handling Unit Fan Selection Guide
KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4
More informationTGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.
TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationWAC Air Curtains Technical Guide
TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2
More informationRERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators
Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for
More informationHVAC INDOOR MAKE-UP AIR HANDLERS
GIAC-8 HVAC INDOOR MAKE-UP AIR HANDLERS Application Manual PACKAGED INDOOR ARRANGEMENTS FOR MAKE-UP AIR, HEATING AND COOLING Contents 2 PAGE GENERAL INFORMATION 2, 3 MODEL NUMBER DESCRIPTION 4 INDOOR DUCT
More informationLIST PRICES WAC AIR CURTAINS
PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM
More informationNON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP
Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10
More informationCH5000 Heat Recovery Ventilator
ADVANCED COMMERCIAL Heat Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 3500-5500 CFM CASING Double-wall cabinet White exterior paint, 22-gauge galvanized steel -gauge
More informationWarm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH
TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System
More informationQuantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)
Mark: ASP 1 Model: ASP - 52.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 52 14 10 740 0.13 Supply Collar
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationINDIRECT FIRED FURNACE PARTS
INDIRECT FIRED FURNACE PARTS 986964 Power Venter (Combustion Blower) Assembly ** S **Includes: Fan, Motor, Housing, etc. (Fasco) 986365 Igniter S 986725 Flame Sensor S 986982 H.S.I. Module 50E47-XXX w/
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationDirect Gas-Fired Make-up Air Heaters
Direct Gas-Fired Make-up Air Heaters SDM-E SERIES OUTDOOR SPECIFICATIONS MANUAL MANUFACTURED BY : BROTHERS LIMITED TABLE OF CONTENTS Summary description of the unit...4 Required burner capacity...6 Dimensions
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and
More informationWarm. SDR Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.
TGSDR- SDR Direct Fired Gas Heating System Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.97M BTUH Sterling Keeps You Warm Featuring the Patented AirTrak controlled Circulation
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin
More informationISO 9001 REGISTERED HTDM SERIES HTDM0600BR
ISO 9001 REGISTERED HTDM SERIES C R R HTDM0600BR TABLE OF CONTENTS Page 1. Standard and Optional Features 2. Efficiencies and Weight Specifications 3. Amperage Specifications & Static Pressure Losses Due
More informationA. NU2035 HRV Specifications NU2035
A. NU2035 HRV Specifications NU2035 B. Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details
More informationModified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges
Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below
More informationERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION
P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity
More informationHorizontal and Vertical BELT DRIVE AIR HANDLING UNITS
Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS TABLE OF CONTENTS H & V Features and Benefits...4 Coil and Filter Data, Static Pressure Data...7 Electric Resistance Heat Section...8 Coil Information
More informationClimas y Proyectos Leyco, S.A. de C.V.
GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More information"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units
"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units Spinnaker Industries Inc. Model Series SPOAU 100% Outdoor Air Systems shall be factory assembled, wired and
More informationforward curved inline duct blowers
Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)
More informationComfortable. Cooling/Heating Comfort Systems. Applied Air. Keeps You. Technical Guide for: IFL TGIFL-4
TGIFL-4 Cooling/Heating Comfort Systems Technical Guide for: IFL High Efficiency, High Turndown, High Filtration Comfort Systems Applied Air Keeps You Comfortable Cooling/Heating Comfort Systems Technical
More informationThis series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
NU2540 ERV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.
More informationThis series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
NU1030 HRV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationWarm. SDFI Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH
TGSDFI- SDFI Direct Fired Gas Heating System Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH Sterling Keeps You Warm Featuring the Patented AirTrak controlled Air Circulation System
More informationDESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER
(3 DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE CONDITIONERS DBUC/DBHB300 25 NOMINAL TONS 8.5 EER DUC and DHB convertible package rooftop models have two independent refrigerant circuits
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2
More informationHORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change
More informationIssue 4 (Record Only) Job #: Innovent Submittal Date: October 30, 2012 Project: Location: Columbus, OH Innovent Job #: Submittal Issue: 4 (Record Only) Engineer: Contractor: Tag Innovent Model # AHU-BG-01
More informationGAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign
3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationGR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility
More informationFS Fan-Coil Units Hi-Rise, Vertical
FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04
More informationSPECIFICATION SHEET. C5000 ( cfm)
(3500 5500 cfm) CASING Double wall cabinet White exterior paint, 22GA steel Galvanized 18GA steel inner wall Access door with ¼ turn handle Insulation : 2 in 18GA Stainless Steel drain pan Drain connection
More informationROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationGas-Fired Separated Combustion Unit Heaters Propeller & Blower Models
6-75. September, 2008 Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models MODEL HDS MODEL HDC MODEL PTS (shown) / BTS 6-75. TABLE OF CONTENTS Modine s separated combustion unit heaters
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationFILTERED SUPPLY CENTRIFUGAL Belt Drive
FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL - BELT DRIVE SECTION 9 Carnes Models VSBB and VHBB centrifugal filtered roof supply fans are available in six sizes - 8 through 20 with
More informationEXHAUST FANS CUD & CUB UPBLAST FANS
EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment
More informationFactory Option Codes L M E S P R D V F F H E
I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity
More informationAIR-AIR ENERGY CONSERVATION MODULE
AIR-AIR ENERGY CONSERVATION MODULE BC-ECW SERIES INDOOR/OUTDOOR INSTALLATION MANUFACTURED BY TABLE OF CONTENTS BC-ECW - Description...3 Components and fabrication details...3-4 Frost prevention & selection
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationHorizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI)
Technical Bulletin Issue Date December 6, 2004 Horizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI) Model AHI Horizontal and Model AVI Vertical Belt Drive Blower Coils are designed
More informationICEMINI & Vertical MTI Units
ICEMINI & Vertical MTI Units ICEMINI Units......K-1 ICEMINI-8MPN (Dimension Information)....... K-2 ICEMINI-8MPN (Horizontal Small)....... K-3 ICEMINI-8MPN (Vertical Small)........ K-4 ICEMINI-8MPN (Vertical
More informationPERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS
50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationRAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL
RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model
More informationSUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER
SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS D1EG/D1EE 180 & 40 15 and 0 NOMINAL TONS 9.5 EER SUNLINE PLUS DESCRIPTION YORK Sunline PLUS II units are convertible single package high efficiency rooftops.
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationSINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION
530.18-TG4Y (600 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D2CE / D2CG 300 CONSTANT VOLUME 25 NOMINAL TONS 8.5 EER DCG Unit Shown DESCRIPTION Sunline 2000 series convertible
More informationDirect Fire Heated Make-Up Air Unit
Direct Fire Heated Make-Up Air Unit Cover1 Culture of Quality Loren Cook Company is proud to be a leader in the design and manufacturing of fans, blowers, gravity ventilators, lab exhaust systems and energy
More informationMODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS
MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive
More informationSUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES
530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000
More informationENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5
ENGINEERED PRODUCTS Model - Unit Type (UT) - MS, Separated Combustion Indoor Unit Capacity (CA) - (50-80) (500-800 mbtu) Furnace Type (FT) - A, B Standard Temperature Rise (30-80)F Indoor Arrangement (IA)
More informationWarm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover
TGATS-4 Air Turnover Systems Technical Guide for: IFP IFS CAT IFA IFJ Standard Gas Heat Air Turnover Non Gas Heat Slave Unit Standard Cooling Only Air Turnover with Prop Fans Standard Cooling Coil Plus
More informationTVS/R FAN COIL UNITS HI-RISE, VERTICAL
TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview
More informationFD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS
SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF
More informationNomenclature. Contents. Air Handling Unit SR AH 250 LP HS
SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal
More informationRemote Air Cooled Condenser
Catalog KM-KDS-0313A UniCon Remote Air Cooled Condenser Kramer s Remote Air Cooled Condensers are designed to provide a wide array of solutions focusing on performance, energy efficiency, reduced sound
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationMAH. Modular Air Handling Unit
MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally
More informationVAHU Vertical Air Handling Unit
500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug
More informationLow Silhouette Power Roof Ventilator Propeller
LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and
More informationElectric Furnace KF/KFS Series
Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationDirect-Fired Make-Up Air Units
Product Catalog Direct-Fired Make-Up Air Units DFIA DFOA November 2009 MUA-PRC007-EN Introduction Why use Trane Makeup Air Units Trane s innovative Direct Fired gas heating systems add warm, fresh and
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationAIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT
ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN
More information8500-Series Indirect-Fired Heating, Cooling and Pressurization Systems Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com GAS/OIL HEATING ONLY RAPID 8500-35 through 8500-125 Upright
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the
More informationGAS-FIRED SEPARATED COMBUSTION UNIT HEATERS
GASFIRED SEPARATED COMBUSTION UNIT HEATERS MODEL HDS MODEL HDC MODEL PTS / BTS 675.7 MAY, 207 TABLE OF CONTENTS Modine s separated combustion unit heaters are designed for the heating requirements of commercial
More informationR6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY
TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility
More information14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON
14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech
More informationEnergy Recovery Ventilator
Energy Recovery Ventilator Page Introduction............................................2 Direct Drive Standard Construction Features..................3 Belt Drive Standard Construction Features...................4
More informationPERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS
50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT
More informationPRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost
Spend study of price carries out by Margins ratios (rate on selling price) Mark up (coef. on cost price) - Overheads 15,00% Mark up (N1) 1,25 - Profits 2,00% - Mark up N 1 1,20 1 - Consulting firm fees
More informationG21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993
ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE GAS FURNACES SYSTEMS 50hz G21Q PULSE21 SERIES UP-FLO GAS FURNACES 11.4 to 27.8 kw (39 000 to 95 000 Btuh) Output Add-On Cooling 5.3 thru 17.6 kw (1-1/2
More informationFIXED PITCH PROPELLER FANS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin
More information200, 9200 & 9200-VIB SERIES
DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive
More informationTubular Centrifugal Fans
Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,
More informationSUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)
511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All
More informationTURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV
TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationPGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT
PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems
More information