1 UR-Series UL077 Recognized Supplementary Protector DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 80Y/277V AC, 50/Hz 0kA Short Circuit Withstand Capacity Applications (on the load side of Branch Circuit Protection) include: Sensitive Electronics, Power Supplies, Appliance circuits, etc. E3795 PENDING UR - Series Voltage Rating Short Circuit Withstand Rating Calibration Temperature Ambient Temperature Storage Temperature Terminal Torque Electrical Life Mechanical Life Vibration Resistance Resistance to mechanical shocks 80Y/ 277 VAC 0.5-0A (RC): 0 ka with no back-up fuse 8-63A (RC): 0 ka with UL-listed Class J back-up fuse; 5 ka with no back-up fuse 30ºC (86ºF) -25ºC to +55ºC (-3ºF to 3ºF ) -0ºC to +70ºC (-0ºF to 58ºF ) max. 2.5Nm (22.2 lb.in) 00 switching cycles ON/ OFF 0000 switching cycles ON/ OFF > 5g according to DIN EN during a load with.05 x I N ms s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r Backup Protection Trip Amp UL-Listed No Backup Fuse Curve Range Class J Fuse Required up to 0kA up to: All 0.3-0A 70A 0kA All 2 - A xrc* 5kA *up to nearest rated current 38 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

2 Time versus Current Trip Curve Seconds Time t Minutes x x B C D For exact trip curves and additinal technical data please refer to pages -6. Dimensions in mm Application Overview Trip-Characteristics* Applications Characteristic Trip Boundaries Thermal Trip Must not Trip>00ms Must Trip <hr Magnetic Trip Must not Must Trip Trip>00ms at 00ms Lighting Wiring Protection Control Circuits Business Equipment Appliances Control Transformers Power Supplies General Electronics Reactive Load B-Characteristics.3xRC.5xRC 3xRC 5xRC C-Characteristics.3xRC.5xRC 5xRC 0xRC D-Characteristics.3xRC.5xRC 0xRC 20xRC *The value of each characteristic is shown vertically beneath its corresponding heading. Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker/Supplementary Protector in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Supplementary Protector for his specific application. Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

3 UR - Series B-Trip Characteristic Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic applications. Relatively long thermal trip delay but low magnetic trip point. C US UL Recognized E3795 One Pole Three Pole Standard Pack: 2.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 277VAC B05UR.0A 277VAC BUR 2.0A 277VAC B2UR 3.0A 277VAC B3UR.0A 277VAC BUR 5.0A 277VAC B5UR 6.0A 277VAC B6UR 8.0A 277VAC B8UR 0A 277VAC B0UR 2A 277VAC B2UR 3A 277VAC B3UR 5A 277VAC B5UR 6A 277VAC B6UR 20A 277VAC B20UR 25A 277VAC B25UR 30A 277VAC B30UR 32A 277VAC B32UR 0A 277VAC B0UR 50A 277VAC B50UR A 277VAC BUR 63A* 277VAC B63UR Standard Pack:.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 80Y/277VAC 3B05UR.0A 80Y/277VAC 3BUR 2.0A 80Y/277VAC 3B2UR 3.0A 80Y/277VAC 3B3UR.0A 80Y/277VAC 3BUR 5.0A 80Y/277VAC 3B5UR 6.0A 80Y/277VAC 3B6UR 8.0A 80Y/277VAC 3B8UR 0A 80Y/277VAC 3B0UR 2A 80Y/277VAC 3B2UR 3A 80Y/277VAC 3B3UR 5A 80Y/277VAC 3B5UR 6A 80Y/277VAC 3B6UR 20A 80Y/277VAC 3B20UR 25A 80Y/277VAC 3B25UR 30A 80Y/277VAC 3B30UR 32A 80Y/277VAC 3B32UR 0A 80Y/277VAC 3B0UR 50A 80Y/277VAC 3B50UR A 80Y/277VAC 3BUR 63A* 80Y/277VAC 3B63UR Standard Pack: 6.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.5A 80Y/277VAC 2B05UR.0A 80Y/277VAC 2BUR 2.0A 80Y/277VAC 2B2UR 3.0A 80Y/277VAC 2B3UR.0A 80Y/277VAC 2BUR 5.0A 80Y/277VAC 2B5UR 6.0A 80Y/277VAC 2B6UR 8.0A 80Y/277VAC 2B8UR 0A 80Y/277VAC 2B0UR 2A 80Y/277VAC 2B2UR 3A 80Y/277VAC 2B3UR 5A 80Y/277VAC 2B5UR 6A 80Y/277VAC 2B6UR 20A 80Y/277VAC 2B20UR 25A 80Y/277VAC 2B25UR 30A 80Y/277VAC 2B30UR 32A 80Y/277VAC 2B32UR 0A 80Y/277VAC 2B0UR 50A 80Y/277VAC 2B50UR A 80Y/277VAC 2BUR 63A* 80Y/277VAC 2B63UR Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) Add-on Neutral Pole A 277/80VAC N63UM Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) Box clamp 8.3 mm (0.72 in.) M5 screw *63A is not UL Recognized. * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 0

4 UR - Series C-Trip Characteristic Application Examples: Low inrush motors, lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point. C US UL Recognized E3795 One Pole Three Pole Standard Pack: 2.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 277VAC C05UR.0A 277VAC CUR 2.0A 277VAC C2UR 3.0A 277VAC C3UR.0A 277VAC CUR 5.0A 277VAC C5UR 6.0A 277VAC C6UR 8.0A 277VAC C8UR 0A 277VAC C0UR 2A 277VAC C2UR 3A 277VAC C3UR 5A 277VAC C5UR 6A 277VAC C6UR 20A 277VAC C20UR 25A 277VAC C25UR 30A 277VAC C30UR 32A 277VAC C32UR 0A 277VAC C0UR 50A 277VAC C50UR A 277VAC CUR 63A* 277VAC C63UR Standard Pack:.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 80Y/277VAC 3C05UR.0A 80Y/277VAC 3CUR 2.0A 80Y/277VAC 3C2UR 3.0A 80Y/277VAC 3C3UR.0A 80Y/277VAC 3CUR 5.0A 80Y/277VAC 3C5UR 6.0A 80Y/277VAC 3C6UR 8.0A 80Y/277VAC 3C8UR 0A 80Y/277VAC 3C0UR 2A 80Y/277VAC 3C2UR 3A 80Y/277VAC 3C3UR 5A 80Y/277VAC 3C5UR 6A 80Y/277VAC 3C6UR 20A 80Y/277VAC 3C20UR 25A 80Y/277VAC 3C25UR 30A 80Y/277VAC 3C30UR 32A 80Y/277VAC 3C32UR 0A 80Y/277VAC 3C0UR 50A 80Y/277VAC 3C50UR A 80Y/277VAC 3CUR 63A* 80Y/277VAC 3C63UR Standard Pack: 6.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.5A 80Y/277VAC 2C05UR.0A 80Y/277VAC 2CUR 2.0A 80Y/277VAC 2C2UR 3.0A 80Y/277VAC 2C3UR.0A 80Y/277VAC 2CUR 5.0A 80Y/277VAC 2C5UR 6.0A 80Y/277VAC 2C6UR 8.0A 80Y/277VAC 2C8UR 0A 80Y/277VAC 2C0UR 2A 80Y/277VAC 2C2UR 3A 80Y/277VAC 2C3UR 5A 80Y/277VAC 2C5UR 6A 80Y/277VAC 2C6UR 20A 80Y/277VAC 2C20UR 25A 80Y/277VAC 2C25UR 30A 80Y/277VAC 2C30UR 32A 80Y/277VAC 2C32UR 0A 80Y/277VAC 2C0UR 50A 80Y/277VAC 2C50UR A 80Y/277VAC 2CUR 63A* 80Y/277VAC 2C63UR Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) Add-on Neutral Pole A 277/80VAC N63UM Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) Box clamp 8.3 mm (0.72 in.) M5 screw *63A is not UL Recognized. * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

5 UR - Series D-Trip Characteristic Application Examples: Control transformers, power supplies, reactive loads. Relatively long thermal trip delay and very high magnetic trip point. E3795 One Pole Three Pole Standard Pack: 2.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 277VAC D05UR.0A 277VAC DUR 2.0A 277VAC D2UR 3.0A 277VAC D3UR.0A 277VAC DUR 5.0A 277VAC D5UR 6.0A 277VAC D6UR 8.0A 277VAC D8UR 0A 277VAC D0UR 2A 277VAC D2UR 3A 277VAC D3UR 5A 277VAC D5UR 6A 277VAC D6UR 20A 277VAC D20UR 25A 277VAC D25UR 30A 277VAC D30UR 32A 277VAC D32UR 0A 277VAC D0UR 50A 277VAC D50UR A 277VAC DUR 63A* 277VAC D63UR Standard Pack:.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) 0.5A 80Y/277VAC 3D05UR.0A 80Y/277VAC 3DUR 2.0A 80Y/277VAC 3D2UR 3.0A 80Y/277VAC 3D3UR.0A 80Y/277VAC 3DUR 5.0A 80Y/277VAC 3D5UR 6.0A 80Y/277VAC 3D6UR 8.0A 80Y/277VAC 3D8UR 0A 80Y/277VAC 3D0UR 2A 80Y/277VAC 3D2UR 3A 80Y/277VAC 3D3UR 5A 80Y/277VAC 3D5UR 6A 80Y/277VAC 3D6UR 20A 80Y/277VAC 3D20UR 25A 80Y/277VAC 3D25UR 30A 80Y/277VAC 3D30UR 32A 80Y/277VAC 3D32UR 0A 80Y/277VAC 3D0UR 50A 80Y/277VAC 3D50UR A 80Y/277VAC 3DUR 63A* 80Y/277VAC 3D63UR Standard Pack: 6.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.5A 80Y/277VAC 2D05UR.0A 80Y/277VAC 2DUR 2.0A 80Y/277VAC 2D2UR 3.0A 80Y/277VAC 2D3UR.0A 80Y/277VAC 2DUR 5.0A 80Y/277VAC 2D5UR 6.0A 80Y/277VAC 2D6UR 8.0A 80Y/277VAC 2D8UR 0A 80Y/277VAC 2D0UR 2A 80Y/277VAC 2D2UR 3A 80Y/277VAC 2D3UR 5A 80Y/277VAC 2D5UR 6A 80Y/277VAC 2D6UR 20A 80Y/277VAC 2D20UR 25A 80Y/277VAC 2D25UR 30A 80Y/277VAC 2D30UR 32A 80Y/277VAC 2D32UR 0A 80Y/277VAC 2D0UR 50A 80Y/277VAC 2D50UR A 80Y/277VAC 2DUR 63A* 80Y/277VAC 2D63UR Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) Add-on Neutral Pole A 277/80VAC N63UM Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) Box clamp 8.3 mm (0.72 in.) M5 screw *63A is not UL Recognized. * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 2 For the latest on Altech Circuit Breakers specifications please visit

6 UR Series Accessories For mounting instructions please refer to page 7. C US UL Listed E37938 Auxiliary Contact, Alarm Switch Type/ Cat No. Description Contacts Type Std Pk H0UM Auxiliary Contact NO 6 HUM 2 Auxiliary Contacts NO + NC 6 H2UM 3 Auxiliary Contacts NO + 2NC 6 H2UM 3 Auxiliary Contacts 2NO + NC 6 HLSM Auxiliary/ Signal Contacts NO + Signal mm Rated Operating Currents Minimum Contact Load Torque Wire Range: Single Wire Stranded Wire Stranded Wire with Ferrule 0A@20V AC 3A@0V AC A@220V AC 2VDC max. 0.8Nm (7 lb.in).0mm² - 2.5mm² (8- AWG).0mm² -.5mm² (8-6 AWG).0mm² -.5mm² (8-6 AWG) 87 mm 52.7 mm 8.8 mm 6 mm Dimensions HxxUM mm 5 mm Shunt Trip Max. Operating Type/ Cat No. Description Un Std Pk FA2UM 2 V AC/DC.3A 5 FA2UM 2 V AC/DC 0.6A 5 FA8UM 8-72 V AC/DC 0.2A 5 FA0UM 0V 0-20 V AC/DC, 20V 277V AC 277V 5 Undervoltage Trip mm 37.5 mm 25.5 mm 20. mm 6 mm 7 mm 89.3 mm.5 mm 3.5 mm 5 mm Type/ Cat No. Line Voltage V E Std Pk UA20UM 20 VAC, Hz 5 Reset-Hold Voltage = 0.85 x V E Drop-Out Voltage = 0.35 ~ 0.7 x V E 7.5 mm 8 mm mm.5 mm 30.5 mm mm 68. mm Dimensions FAxxUM, UA20UM, N63UM. Neutral Pole Type/ Cat No. Rated Current In Rated Voltage Std Pk N63UM A 277Y/ 80 VAC 5 Mounting Screw 3mm to connect the auxiliary contact and shunt trip or neutral Pole to the circuit breaker. Type/ Cat No. Standard Pack Touch Protection Caps to cover the terminal screws on the switching devices, neutral Poles and shunt trips for increased touch protection. Type/ Cat No. Standard Pack BS.UL 00 E Lock-out Adapter Type/ Cat No. Standard Pack EASS 0 3

7 UR Series Trip Curves B Trip Curve C Trip Curve D Trip Curve.3-.5xI N xI N xI N x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC A Through 0A Rated Current A Through 0A Rated Current A Through 0A Rated Current.3-.5xI N xI N xI N x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC A Through 63A Rated Current A Through 63A Rated Current A Through 63A Rated Current B Magnetic Trip Parameters Rated current.0a to 63A.. Hold for a minimum of 00ms at surge of 3 times rated current. 2. Trip in under 00ms at 5 times rated current. C Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 5 times rated current. 2. Trip in under 00ms at 0 times rated current. D Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 0 times rated current. 2. Trip in under 00ms at 6 times rated current. For the latest on Altech Circuit Breakers specifications please visit

8 UR Series Internal Resistance Rated Current Trip Characteristic (A) B C D (Ohm) (Ohm) (Ohm) / / / / 63* Mounting Instructions for UL89, UL508 and UL077 Accessories Neutral / Shunt Trip plus possibly Auxiliary Contact Neutral Switch/ Shunt Trip Switching Device Neutral Switch/ Shunt Trip Auxiliary Contact mm 3.. Mounting screw 3mm 2 mm Neutral Poles N63UM, N32UL, N63UL or Shunt Trips FA..UM, FA..UL can be mounted on right or left side of device. 2. Bring blue knob of all devices into OFF position. 3. Remove grey cover from the switching device and attachment.. Insert drive plate between switching device and Neutral Poles N63UM, N32UL, N63UL or Shunt Trips FA..UM, FA..UL. 5. Insert connecting pin into knob. 6. Combine switching device and Neutral Poles N63UM, N32UL, N63UL or Shunt Trips FA..UM, FL..UL. 7. Screw device together. 8. Possibility of mounting Auxiliary contact H...UM, H...UL additionally on the right only, different screw type (see E9839 accessories) necessary. Auxiliary Contact Switching Device Auxiliary Contact Auxiliary can be mounted on right side of device only. 2. Bring blue knob of both devices into OFF poistion. 3. Remove grey cover from switching device.. Combine switching device and Auxiliary Contact H...UM, H...UL. 5. Insert connection screws and connect the two devices by turning the screws by After mounting close and open to check operation. 2.

Typical UL1077 Application

Typical UL1077 Application Altech UL77 Typical UL77 Application Control Circuit of a UL508A Panel Disclaimer: This is just an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Control Circuit of a UL508A Panel. Typical UL1077 Application

Control Circuit of a UL508A Panel. Typical UL1077 Application Altech UL077 Typical UL077 Application Control Circuit of a UL508A Panel Disclaimer: This is an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers

Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers UL 89 ANNEX Since 98, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering,

More information

Typical UL489 Application Power Circuit of a UL508A Panel

Typical UL489 Application Power Circuit of a UL508A Panel Altech UL489 Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications..

More information

Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel

Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel Typical UL508 Application Power Circuit of a UL508A Panel Altech's V-EA UL508 Manual Motor Controllers are approved for Group Installations Disclaimer: This an application example. Installation should

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Altech UL1077/508 Busbar System

Altech UL1077/508 Busbar System Altech UL1077/508 Busbar System UL1077/508 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Manual Motor Controllers (MMC) and Supplementary Protectors (SP). The

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3 Index L Springer Controls carries a complete line of Techna Miniature Circuit Breakers rated from 0.5 amps through 63.0 amps. Applications include usage in UL508A panels, motor group installations, motor

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature Circuit Breakers US CATALOG Miniature Circuit Breakers Miniature circuit breakers Table of contents S(U)200 series miniature circuit breakers UL 489 series Description and features 2 SU200M-C 3 SU200M-K 4 SU200M-Z 5 SU200MR-K

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

US CATALOG. Miniature circuit breakers

US CATALOG. Miniature circuit breakers US CATALOG Miniature circuit breakers Table of contents 004 024 S(U)200 series miniature circuit breakers UL 489 series 025 048 S200 series miniature circuit breakers UL 1077 series 049 056 Application

More information

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2 S00-C, 480Y/77 VAC UL 077, CSA. Miniature C S0-C S0-C S03-C S04-C S0-CNA + NA 0.5 S0-C0.5 0.5 S03-C0.5 S0-C S03-C.6 S0-C.6.6 S03-C.6 S0-C S03-C 3 S0-C3 3 S03-C3 4 S0-C4 4 S03-C4 6 S0-C6 6 S03-C6 8 S0-C8

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

QF(13) - Series Miniature Circuit Breakers

QF(13) - Series Miniature Circuit Breakers DIN Mount 1 pole DIN Mount 2 pole Dual Mount 3 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three, four

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Circuit Protection. Circiut Protection

Circuit Protection. Circiut Protection Circuit Protection Series L8 UL1077 Supplementary Protectors...2 Selection Guide - Trip Curve "B"...4 Selection Guide - Trip Curve "C"...5 Selection Guide - Trip Curve "D"...6 Accessories...7 Technical

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

...at Altech, of course!

...at Altech, of course! FANTASTIC approved FERRULES...at Altech, of course! Approved for the US & Canadian Market Other great Altech CSA approved products: Miniature Circuit Breakers / Manual Motor Controllers DIN Rail and Panel

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

QF(19) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole,

More information

ER circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic, ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Abox-i Series. petrochemical plants, steel mills and railways.

Abox-i Series. petrochemical plants, steel mills and railways. Series Series (formerly the Nautic Series) junction boxes for harsh environments are supplied complete with terminal blocks. These enclosures can be used wherever extreme conditions are encountered: offshore

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

G-Series DIN-RAIL CIRCUIT BREAKER

G-Series DIN-RAIL CIRCUIT BREAKER G-Series DIN-RAIL CIRCUIT BREAKER The G-Series hydraulic-magnetic circuit breaker insures maximum protection by integrating wiping contacts for longevity; a common trip linkage between poles; a unique

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73 Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 perating Characteristics 73 Delay Curves 74 Specifications 76 Decision Tables 78 SIGLE

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Proline Panelboard and breakers

Proline Panelboard and breakers Proline Panelboard and breakers ProLine & breakers ProLine The ProLine is the electrical industry's first limiting, touch safe, fully coordinated UL 67. Electrical: UL File #E319800 UL67 225A and 400A

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

MS-Series. Circuit Breaker

MS-Series. Circuit Breaker MS-Series Circuit Breaker Carling Technologies MS-Series Sealed Toggle Circuit Breaker was designed and tested to operate flawlessly in the harshest of environments. Ideally suited for COTS (commercial

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information