Instruction Manual SILA-MSYP-160

Size: px
Start display at page:

Download "Instruction Manual SILA-MSYP-160"

Transcription

1 Instruction Manual SILA-MSYP-160 Permanent Magnets Synchronous Machine for Elevator LANCOR 2000, S.L. Pol. Ind. El Campillo, FII, P Abanto y Ciérvana Bizkaia Spain Lancor SILA_MSYP-160_Manual_v4_ENG.doc

2 Revision Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 2 of 48

3 TABLE OF CONTENTS 1. General Information About this Instruction Manual Usage Exemption from liability Copyright Technical data Nameplate Motor designation Machine configuration Motor Traction Sheaves Brakes Encoder General safety instructions Transportation and storage Transportation Storage Installation Installation verification Operations Motor Brakes Encoder Encoder output contactors ECN Operating conditions First receipt Verification of elevator functionality, start up Brakes testing Check "failure of a brake coil" Half-load testing Overload testing Emergency evacuation Brake microswitch testing How to remove the cabin from wedging Operational failure High temperature of the machine Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 3 of 48

4 The brake does not open The brake does not brake Noise with brake opening and closure Motor does not start Noises in the motor Table of possible problems and solutions Assistance and maintenance General notes on maintenance Inspection frequency Machine variants General dimensions MSYP Technical data MSYP Spare parts Instruction Manual of the Brake Alzola brakes drawings Alzola brakes conformity statement Encoder technical data Encoder detail Encoder conformity statement Compact Fan specifications Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 4 of 48

5 1. General Information 1.1. About this Instruction Manual This Instruction Manual corresponds to functioning and control of SILA Gearless Permanent Magnet Synchronous Machines produced by LANCOR 2000, S.L. This Instruction Manual forms part of the machine and must be kept nearby for reference purposes. All staff members involved in installation, handling, maintenance or repairs of the machine must have read and understood this Instruction Manual. Lancor 2000, S.L. shall not be held responsible for any damages or malfunctioning caused by failure to follow the indications provided in this Instruction Manual Usage SILA MSYP-160 machine consists of a permanent magnet synchronous motor without gears (Gearless) and it has been specially designed for application in modern elevators as a substitution to a classic gear motor combination. This machine may not be used for any other purposes without obtaining prior consent from LANCOR 2000, S.L. This SILA machine features all advantages sought in modern elevator equipment: easy installation, good control, low noise level and compact design Exemption from liability LANCOR 2000, S. L. shall not be held responsible for any damages arising from incorrect usage of the machine or inappropriate use or from modifications or repairs which have not been authorized by LANCOR 2000, S L Copyright Copyright of this Instruction Manual is property of LANCOR 2000, S.L. This Manual may not be partially or entirely reproduced or used in a non-authorized manner without obtaining prior consent from LANCOR 2000, S.L. The Design of the machine SILA MSYP-160 is duly registered as Utility Model. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 5 of 48

6 2. Technical data 2.1. Nameplate Each "SILA" machine contains an identification nameplate, which includes data corresponding to the motor, traction sheave, Identification Number and Serial Number. as indicated, with the following values: Load_roping_tr.sheave Ø / Lancor ID# Supplier ID# Machine type/poles Rated Power Rated Voltage Frequency Rated Current Max. Current Isolation class Cooling grooves x cable Ø Machine Serial Number Star connection Duty cycle conn./hour Rated Speed Rated torque Max. Torque Enclosure Machine Weight Production Date (mm-yyyy) 2.2. Motor designation 2.3. Machine configuration Permanent Magnet Synchronous Motor Motor Size Core Length x 2 (cm) Number of Poles MSYP "SILA" machine consist of a motor, a brake, a traction sheave and an encoder. A client may choose the inverter used for supplying power and controlling the machine, although LANCOR has tested machines with inverters from Yaskawa, Control Techniques, Vacon and Fuji Electric brands. Repair of individual parts by the user or an installer are not described in this Instruction Manual. Such repairs should be carried out by the part manufacturer or after contacting LANCOR 2000 for further instructions Motor Synchronous motor, of robust construction, is equipped with NdFeB permanent magnets with a large intrinsic energy capacity, which deliver the necessary excitation supply to the motor for its correct operation. Power supply and control are carried out through a frequency controller. Machines are designed with FEM (Finite Elements Method), which guarantee low vibrations and noise levels. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 6 of 48

7 2.5. Traction Sheaves Traction sheaves are made from GG30 cast, from Ø160 to Ø320 mm, with different number of grooves and diameters of standardized steel cable. They transmit the movement, and each one is designed for different loads and speeds. Refer to assembly and dismantling instructions on page Brakes SILA MSYP-160 machine is equipped with a brake with compression springs activated by direct current. The patented multi-polar winding and sequential functioning system they use, make them the perfect solution due to its hight performance and minimum volume. They are certified as a mechanism against upward over-speeding, in accordance with the 95/16/EC directive and EN A3. The brake consists of a multi-polar winding case, and a brake disk, which rotates in conjunction with the shaft by means of a gear. It has asymmetric mobile plates. They act sequentially, which allows a reduction in the noise level and maximum comfort when stopping. The brake of the MSYP-160 machines is manufactured by Alzola, and there are different types, depending on the required brake torque. Refer to the corresponding instructions for any operations involving brakes Encoder Encoder is an electronic element which indicates rotor position and motor speed to the frequency controller. It performs a basic and fundamental role in motor functioning, which would not work without it. A wide range of encoders is available on the market, with different output signals, such as absolute, sin/cos, incremental, etc. Lancor has chosen the Absolute type (unless other type requested by the Client), since this type ensures the best motor response. It is placed opposite the sheave, next to the brake. (Pg 12) 3. General safety instructions 3.1. Installation and preventive maintenance of SILA MSYP machines require the services of qualified staff. Staff members must have an in-depth knowledge of elevator installation, assembly and operation and must read and understand this Instruction Manual The Company shall not be held liable for any damages arising from undue handling, which does not comply with EN-81-1 safety regulations on elevator constructions and other applicable regulations, such as UNE-EN ISO Machines are equipped with lifting lugs welded at the central part of the motor, designed to lift the weight of the machine for elevating it until it is placed into a selected location for installations or for transportation. Therefore, no additional weight may be affixed to them When performing works on the machine, it is necessary to establish a safety area, with barriers, screens and other devices employed to prevent outside individuals from accessing this service When the machine is stopped, no current is supplied from the regulator, and if the brakes are opened, it is possible that an uncontrolled acceleration of the elevator would occur. Therefore, it is advised to shortcircuit main clamps with a contactor. The torque produced by the induced currents when turning, will decrease motor revolutions. Such short-circuiting must be carried out when the motor no longer receives the current from the inverter and it must never be done when it still has the current Brakes are safety components and thus they may not be dismantled or disconnected, especially when the machine is operational For thermal protection, the machine is equipped with 3 PTC sensors of 120ºC, embedded in the stator winding, which protect the motor from excessive overheating above magnet demagnetization temperature. If such sensors are activated, the machine will be stopped and placed out of service. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 7 of 48

8 3.8. The machines are equipped with an additional ventilation system, which consists of a Normally Open bi-metal thermocouple of 70ºC, which will close the circuit if such temperature is reached. Its purpose is to activate 2 electric fans (or only one, depending on the machine type), which will cool down the machine. These fans are placed on a metal sheet over the stator, and they blow air from outside towards the stator surface. 4. Transportation and storage 4.1. Transportation SILA machines are supplied and packaged in accordance with Client specifications Machines must be transported in their original packaging. Additional load may not be placed on top of the machines Avoid excessive vibration and pushing during transportation A visual inspection will be performed once the machine is received and unpacked. Upon detection of any transportation-related damages, a claim will be filled out in the presence of the carrier. Damages occurred during transportation are not covered by our guarantee Storage The machine must be stored in its original package, in a dry area, without any vibrations and protected from adverse weather conditions and dirt until it is installed. It should not be stored for longer than 1 year, and in such a case, the motor must be moved by hand prior to assembly (opening the brakes) in order to verify that there are no strange noises in the bearings Avoid extreme cold or heat (storage temperature must be between -20º and 50ºC), as well as frequent temperature fluctuations Avoid condensation or excess humidity and conditions of aggressive humidity (i.e. salt humidity). 5. Installation 5.1. Installation verification SILA machines leave the factory being completely finished, checked, painted and in corresponding packaging. A copy of the Final Test Report is included in the package Installation, connection to a power source and placement in operations must only be performed by qualified staff and in accordance with connection schemes and manufacturer instructions If a machine has been stored for some time, a maximum of 1 year, insulation resistance of motor windings and brake coils must be checked with a megohmeter. Obtained value must be greater than 50 MΩ (500 VDC megohmeter). If this value is not reached, parts must be dried in order to remove humidity. To do so, hot air is directed to the motor or brakes as long as it may be necessary in order to verify that the coil is exposed to a temperature >70ºC. After repeated measurement of insulation resistance, obtained value must be by far greater than the indicated one (50 MΩ). Do not supply power to the motor and brakes with insulation resistance values less than indicated above, otherwise, insulation breakdown may occur, leading to short-circuiting of windings It is possible that the brake disk sticks to the braking surface of the motor frame, especially after prolonged storage and it must be freed up. Therefore, supply must be applied to the brake, and a cutter must be placed between the disk and the braking surface, to release it. It if is not released, the brake case must be dismantled and the disk should be hit with a mallet in order to free it up. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 8 of 48

9 Open the brakes, applying voltage to the coil and run the machine in both directions without load, with the inverter. Make sure that the voltage applied to the motor by the inverter is similar in both directions Check the nameplate and enclosed documentation to make sure that they coincide and the machine is the one that in fact needs to be installed Machines are ready for operations in a machine room or in upper or lower parts of the elevator shaft, as well as in the space between the elevator and the wall, as close to the wall as possible The machine must never be assembled on top of the cabin During installation, the machine must be attached to a baseplate especially designed for this purpose. It must be attached by four M-16 screws through threaded holes in the motor frames, placing the screws through the lower part. M screw tightening torque: 210 Nm The shaft of the machine is of critical importance for correct operations, thus it should not be hit or be exposed to loads that are not intended for the elevator Cables must go up and down in a vertical manner in regard to motor feet and the wrap angle with the sheave must be of at least 150º No welding is allowed at the machine, which must not be used as a base table for welding works, since the current may damage the magnets and bearings In order to buffer vibrations, rubber absorbers, which will absorb potential vibrations, must be placed between the machine feet and the baseplate prior to placing mounting screws If the sheave has more grooves than required for the cables, they must be placed as close as possible to the motor, in order to reduce the load on the bearings and expand their useful life. placement Incorrect placement Correct Supply to the brake the voltage indicated in specifications, check that the brake opens and closes correctly Brakes are safety elements, so if chip cutting works are performed next to the machine, it must be protected from the chips and dust The brake is attached to the motor support by Hexagonal head screws. These screws are fastened with a corresponding tightening torque. Screw M10 M12 M16 Torque 49Nm 85Nm 210Nm The traction sheave is placed at the factory, but apart from a visual inspection, in order to confirm its Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 9 of 48

10 correct assembly it is necessary to confirm with a torque wrench that sheave axial fixation screws are tightened. These screws have a lock washer which prevents the screw from turning. Tightening torque M12 8.8: 85 Nm If the sheave is placed incorrectly or has some flaws, it has to be dismantled and re-assembled. Therefore, difference must be made between the machine prior to assembly at an installation and already assembled at an installation: Dismantling prior to assembly at an installation is easier (see ) If the machine is assembled at the installation, power supply to the machine must be interrupted and necessary measures must be taken in order to avoid a possible re-connection prior to end of the operation. The cabin and the counterweight should be fixed and the sheave should be dismantled as indicated below Assembling and dismantling the sheave Sheave dismantling: Remove cable anti-exit protectors by loosening the screws used to attached them to the motor frame, and remove the cables. Afterwards, axial fixation screws are loosened and the sheave axial fixation washer is removed. The sheave fits with a cone at the shaft; extract the sheave by using an adequate extractor. Pay attention as to avoid damaging the shaft. Sheave assembly: Clean the shaft from possible residue, place the shaft key and the new sheave. Using a plastic mallet (to avoid damage), hit as close to the center and randomly around the entire girth of the sheave. After that, adjust the axial fixation washer and tighten M12 screws to 85Nm by using a torque wrench in order to achieve adequate fastening. Next, bend the anti-swivel washer in order to prevent the screws from loosening up. Lastly place the cables and anti-exit cable protections, adjusting the distance from the sheave to 4 mm. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 10 of 48

11 6. Operations Never try to run the machine by applying line voltage, since it may cause an electric failure Motor The general connections diagram is placed inside part of the terminal box cover, as indicated below. Lancor machines feature other available connection options, such as with a motor cable shielded hose or with a connector, including an option to remove the terminal box, in accordance with Client's specifications As shown on the diagram, the microswitches of the brake are factory-equipped with NC contactor usage. NO contactor is not used, although the Client may use it by changing the connection Motor power supply cables must be connected to U-V-W terminals, both at the motor and at the inverter, respecting the phase sequence, because otherwise the encoder will emit an erroneous signal and the elevator could be out of control Verify proper operation of power supply contactors and their electrical connection Motor protectors must be connected correctly and be ready for operations, as well as disposing of a Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 11 of 48

12 connected earth wire Check that connection data corresponds with the data indicated in the nameplate Make sure that the assembly and electrical installation have been properly performed Remove all foreign items and garbage from the installation location Check that PTC thermal protection is ready. To do so, measure its ohmic resistance, which must be between 20 and 250 Ohm Check that the bimetallic thermocouple is Normally Open. To do so, check that its resistance reaches MGO values. The power supply for the fan(s) is 24VDC. Positive in terminal 8 and negative in terminal VE Brakes Before carrying out any operations, refer to the instruction manual for corresponding brakes Verification of brake opening and closure, as well as the monitoring must be performed by applying the voltage indicated in the instructions through an uninterruptible power supply. These brakes can be equipped with a Manual Brake Release System Brakes are monitored by microswitches of two contactors (NO and NC). These contactors must be at least of 25mA Brakes must be protected from voltage surges from power switching by using varistors Power will be supplied to brakes with the electric current, once they are connected to the motor and all motor and inverter cables are placed Brakes are designed for static braking, acting once the speed is reduced to zero. Therefore, dynamic braking, or brake operating when the motor is rotating, must be reserved for emergency circumstances or for inspection Place brake power supply cables according to the voltage and current indicated in instructions Power is supplied to brakes by DC Voltage, thus a rectifier bridge is required. Lancor offers a power supply kit for the brakes. It is recommended to operate the brakes with two contactors, one at the AC-side and another at the DC-side. Switch-on always takes place AC-side. Only then is the overexcitation activated. Switch-OFF If short switching times are required (e.g. for EMERGENCY STOP operation), please switch DC-side. The AC-side always has to be switched as well in order to activate overexcitation. If a longer brake engagement time or a quieter switching noise is required, please switch AC-side Encoder Refer to assembly and dismantling instructions provided on the next page In order to avoid interferences with electronic devices, the motor power supply cable must be shielded with ground grid, connected to the ground of the motor and the inverter Once the inverter's autotuning process is complete, the encoder must NOT be loosened or moved from its position, otherwise this adjustment will be lost and another autotuning will have to be carried out (refer to the instructions on the inverter) Never touch encoder contactors or wire connectors with bare hands, since electrical components may be damaged by electrostatic discharges. If necessary, touch immediately before any grounded conductor. This way, any possible static load will be discharged. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 12 of 48

13 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 13 of 48

14 6.4. Encoder output contactors ECN 413 Pin Signal GN/BK...A+ WH/GN...0V BL/BK...B+ BN/GN...Up GY...DATA VI...CLOCK YL/BK... A- WH...0V RD/BK...B- BL...Up PK...DATA YL... CLOCK 6.5. Operating conditions The SILA MSYP-160 machine is designed for operating conditions corresponding to regulation EN81-1 on (Elevator motors), correct performance is guaranteed under the following environmental conditions: Room temperature between 5 ºC and 40 ºC. Maximum relative humidity of 90% at 25 ºC. Maximum altitude of 1000 m. over the sea level. Dry and lubricant-free transfer cables. Machine operating under values other than those aforementioned may lead to failure. Please check with Lancor's technical department in case of any variations of these values First receipt The following must be verified before the first placement into operations. Installation and connection to a power source were performed correctly. Safety devices have been installed. All foreign/assembly materials have been removed. The load corresponds to the information provided in the nameplate. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 14 of 48

15 7. Verification of elevator functionality, start up 7.1. Brakes testing Prior to carrying out any testing, make sure that the brakes function correctly. To do so, it is recommended to place the car without any load in the middle of the elevator shaft, open the short-circuit contactor at motor terminals and supply voltage to the brakes. The cabin will go up, being pulled by the counterweight and voltage supplied to the brakes will be disconnected, thus allowing to check whether they function correctly and stop the cabin. If the elevator does not stop, the short-circuit contact will be activated again. This test is a dynamic one, that is, the brakes are applied while the motor is turning, and therefore it must only be carried out during inspections or in case of emergency Check "failure of a brake coil" The objective of this test is to verify whether the brake is capable of bringing the elevator to a stop, despite a failure of one of its coils. To do so, a nominal load will be placed in the elevator's car, and it will be sent down at its normal operating speed. In order to simulate failure of one of the coils, power should be supplied to them independently through the start/stop keys and then cut off the power supply to all coils except for one. The elevator should slow down and stop. If this does not happen, voltage supply shall be removed from this coil, and the short-circuit contactor will be activated at motor terminals for stopping it. THE INSTALLATION MUST BE PLACED OUT OF SERVICE IN ORDER TO CHECK THE BRAKES! On the general diagram it is shown that power supply to the coils is provided by terminals 1-2. In order to perform the above test, remove the cables from one of the terminals and bring them to the indicated start/stop circuit, perform the test and place them back at the same place. Repeat the same procedure for the next coil. Lancor shall not be held responsible for poor handling or testing errors Half-load testing This test is carried out in order to verify the load balance possessed by the installation, since a cabin with a half-load is balanced. In other words, at any point of the installation, depending on the situation of the cabin, it will go up or down only due to the weight of the cables. To do so, place the cabin in the middle of the elevator shaft, open the brakes, maintaining motor terminals short-circuited. If it does not move, the short-circuited contactor of the motor terminals will open up in sufficient time to see if it goes up or down. Once verified, activate the contactor so that the elevator will not move Another manner of viewing it is to open the brakes and supply power to the motor and the inverter, up and down, measuring the current in each direction. The difference should not be greater than 10% Overload testing This is carried out to verify that the brakes are capable of stopping an elevator even with an overload. To do so, 125% of rated load will be placed in the cabin and it will be sent down at the nominal speed, interrupting power supply to the motor and the brake. The elevator should stop due to application of brakes. This test is a dynamic one, since the motor is turning and the brakes are only prepared for static braking, that is, when the motor is at zero speed. Therefore, it must be carried out as few times as possible due to possible deterioration Emergency evacuation Emergency evacuation due to power supply failure shall be carried out through electric opening of brakes, unless the machine is equipped with Manual Brake Release System option. The elevator will move Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 15 of 48

16 up or down, depending on the load. In order to avoid a possible loss of control upon machine acceleration, motor terminals must be connected in short-circuit, this will make the motor turn at a very slow speed, since it originates at a very significant decelerator torque, which is convenient for rescuing from any close-by door Brake microswitch testing The brakes are equipped with a microswitch, which consists of two contactors, NO and NC, which change status when the power is supplied to the brake and are used for monitoring, since it allows us to know exactly whether or not the brake has been activated. These contactors must be tested individually, and if the signal is faulty or incorrect, the elevator must be stopped, since this can lead to a power cut. These contactors are labeled on a general diagram and NC signal is placed on the terminal plate. If desired, the Client may change to NO, which is available. (Diagram on Pg. 10) 7.7. How to remove the cabin from wedging. If the elevator with a nominal load becomes locked during technical testing or while operating, the cabin will be firmly held by the wedge support, impeding its movement. Therefore, it has to be disengaged. This is carried out by pulling the cabin with the machine itself. The maximum motor capacity is around %. If we need 100% to move the load and this interlocking is requesting more, the motor will not have much additional capacity, which may not be sufficient from releasing the cabin. If the cabin is close to a door, the load can be decreased a little, which will allow the machine to have more capacity for operations. If this is not possible, use a manual hoist for pulling the cables. Therefore, it is recommended to get one and have it available. These machines are not equipped with a flywheel that can be operated manually, since the impact is direct and gearless, applied force is extremely high. In addition, they are located in the elevator shaft, which is of difficult access Operational failure High temperature of the machine The SILA MSYP-160 machine is equipped with PTC K 120º thermal protection with ohmic output. If extended properly, it can stop the machine and avoid deterioration of windings or magnets. In addition it has a bi-metallic thermocouple of K70º with NO contactor for automatic functioning of the ventilators. Firstly, we'd have to analyze the reasons for overheating, as it may occur for different reasons: intense traffic for a long period of time, high room temperature, inverter imbalance and elevator overload, among others. To rectify this, machine ventilation should be improved. After checking that the fan(s) are working properly it will be necessary to improve elevator shaft ventilation and to check that the inverter parameters are well configured and that the elevator is not overloaded The brake does not open The brake is the most important part of the machine because it is a safety element. Therefore, it must be checked continuously. There could be various possible reasons for it: first, use a voltmeter to verify that the power supply voltage is the recommended one for the brake. Likewise, check that signal monitoring from microswitches, NO and NC contactors is correct. Check that the brake coil is in perfect condition. To do so, measure the ohmic resistance of the coil with a polymeter, which should be according to the brake instruction manual. If the air gap is too big, the coil would not have sufficient magnetic energy for closing the circuit and the brake will not open. Air gap is measured with a gauge. It must be even and equal to 0.25 mm. If the brake does not work after correcting it, the distance must be gradually increased up to a maximum of 0.5mm. If it still does not work, replace brake disks, since brake lining is worn out. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 16 of 48

17 The brake does not brake The principal cause is wearing out of brake liners, which leads to changing brake disks. Refer to brake dismantling instructions and contact Lancor 2000, S.L. in order to obtain a new disc Noise with brake opening and closure The brake may generate an unpleasant noise upon opening or closing. To buffer it, check that the air gap is even and adjust it if necessary. Additionally, brakes should always be switched at the AC power supply side, since coil inductance buffers such noise. Alignment of a brake disk with the braking surface is also very important. They must be placed as parallel to each other as possible, the disk has a gear with an axis, a rubber O-ring seal which buffers such noise if it is placed correctly and it is in a good condition Motor does not start There are several possible reasons for this. First, verify that the frequency regulator is working correctly and that there is adequate voltage supplied to the motor. If the motor is started to the first time, check that the motor's and inverter's phases are connected adequately. Another aspect to be checked is whether the brake opens correctly and microswitch monitoring is correct, since the motor will not start if it closed. If after these verifications the motor still does not start, this could be caused by the encoder, which was moved from its original position. Autotuning process will have to be performed again (refer to instructions on inverter for this procedure). If the motor still does not start and inverter's functionality has been confirmed, the encoder should be replaced as it could be causing this problem Noises in the motor If a strange noise is heard upon starting, this may be caused by a defective bearing. In this case, the motor must be dismantled and sent to Lancor 2000 for replacement. It may also be caused by an incorrect inverter parameters adjustment, so input data must be reviewed in order to avoid errors. If everything is correct, check encoder connections, since it can also be causing noise. Once the encoder is substituted (refer to dismantling instructions), perform autotuning once again and confirm that the noise has disappeared. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 17 of 48

18 Table of possible problems and solutions PROBLEM CAUSE SOLUTION High room temperature +40º Improve ventilation in the elevator shaft Excessive temperature Ventilation system is activated Motor overload Motor stator is covered Follow specifications on machine load Check brake opening Check that the motor is not covered or does not have excessive thermal insulation High volume of occasional traffic Inverter not adjusted Check inverter adjustments Encoder has moved Perform autotuning (pole-tuning) (REFER TO INSTRUCTIONS ON INVERTER) Wrong connection of phases Check motor-inverter connections Motor does not start Wrong condition of inverter Check inverter Brake coil does not open Check electrical part of the brake Verify the lack of sticking (brake shoe stuck to a brake disk). Incorrect inverter adjustment Review entry data to avoid errors Strange noises in the motor Defective bearings Encoder issues. (Perform autotuning after moving the encoder) Dismantle the machine and send to Lancor for this operation. (Guarantee will be lost if the machine is opened). Check connections Substitute encoder (Refer to dismantling instructions) Incorrect power supply voltage Check power supply The brake does not brake Issue with contactor monitoring Check whether the selected contactor (NO or NC) is correct and well connected. (Monitor brakes). Issues with brake coil Measure electrical resistance of the coil and check brake instruction manual. Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 18 of 48

19 Excessive air gap. (worn-out lining) Check that air gap is between 0.25 and 0.6mm) (If greater than 0,6 mm, contact with Lancor to change worn out lining). Transportation screws in place. Remove transportation screws. Manual brake release activated Deactivate manual brake release Abnormal noise from the brake Incorrect contactor monitoring Concerning noise during opening closure Noise in brakes at turning. Poor condition of microswitch Dirty microswitch Check air gap uniformity and adjust if necessary. Check that the lining-brake-motor frame are in parallel Check idle and at load and substitute the contactor or the brake Clean and excite with a load of 8-10mA Check idle and at load Change microswitch Erroneous switching in power supply to coil Check switching relays between AC and DC. Strong noise in brake switching Excessive air gap. Worn-out O-ring seal Check and regulate brake lining. If that is not possible, contact Lancor to obtain substitution. Contact Lancor for spare parts. Non-sufficient power supply Adjust to adequate voltage Non-sufficient opening voltage Adjust initial voltage The brake does not open Problem with Brake Power supply Air gap less than 0,25 mm Damaged coil Check power source and microswitches. Change brake lining Change brake Too little time for over-excitation Increase time allocated to overexcitation. 8. Assistance and maintenance 8.1. General notes on maintenance Comply with occupational hazard regulations. Pay a lot of attention if you hear strange noises in the machine, notice irregular operations or abnormal consumption. Take appropriate action as each one of such issues may cause safety problems in the elevator. The machine must only be handled by qualified staff with corresponding training. If this requirement is Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 19 of 48

20 not met, refrain from dismantling, changing or making adjustment to the machine in the absence of such staff members. Bearings have permanent lubrication. Lubrication is not necessary since they are already sealed and the existing grease remains available during the entire useful life. Check brake lining consumption, which should be done with open brakes, that is, with power supplied to them. Therefore, to do so, make sure that the cabin and the counterweight are standing still and mechanically fixed. If it is not very worn out, it may be regulated by adjusting the airgap of the brakes up to its maximum value. After that, they cannot be regulated any further and the lining must be changed Inspection frequency Operation Check for noise in the bearings. Status of traction sheave channels. Brake air gap control Period 3 months 6 months 1 year χ χ χ χ χ χ χ χ χ Notes Only noise, bearings are greased. Cleaning and wear Between 0,25 mm and 0,6 mm. Ventilation kit operations χ χ Supply 24VDC between terminals 8 and VE2. (in order to check ventilator functionality) Traction sheave fixation χ Verify tightening torque as per specifications Traction cable protection χ There should not be any rubbing or vibrations. Electrical connections Motor insulation resistance χ χ χ χ Hose and terminal screws Perform measurements between phases and ground Machine cleaning χ χ χ Maintain the area clean and obstacle-free for its correct ventilation. Mechanical attachment to the baseplate Brake operations status χ χ Verify tightening torque as per specifications Refer to brake manual Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 20 of 48

21 9. Machine variants 9.1. General dimensions MSYP-160 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 21 of 48

22 9.2. Technical data MSYP Spare parts Spare parts and accessories which are not supplied by LANCOR have not been approved by our Technical Department. If they are installed on a machine it is possible that they will not comply with quality and safety requirements. Therefore, LANCOR shall not be held liable or provide any guarantees in regard to damages caused by non-approved spare parts. Please find a list of approved spare parts for SILA-MSYP-160 elevator machines in the separate document: Spare_Parts_for_MSYP-160_v1.doc Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 22 of 48

23 11. Instruction Manual of the Brake Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 23 of 48

24 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 24 of 48

25 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 25 of 48

26 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 26 of 48

27 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 27 of 48

28 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 28 of 48

29 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 29 of 48

30 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 30 of 48

31 11.1. Alzola brakes drawings Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 31 of 48

32 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 32 of 48

33 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 33 of 48

34 11.2. Alzola brakes conformity statement Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 34 of 48

35 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 35 of 48

36 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 36 of 48

37 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 37 of 48

38 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 38 of 48

39 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 39 of 48

40 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 40 of 48

41 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 41 of 48

42 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 42 of 48

43 12. Encoder technical data Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 43 of 48

44 12.1. Encoder detail Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 44 of 48

45 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 45 of 48

46 12.2. Encoder conformity statement Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 46 of 48

47 13. Compact Fan specifications Compact Fan model: 4715KL-05W-B10 Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 47 of 48

48 LANCOR 2000 S.L Pol. Ind. El Campillo, F2 P Abanto (Bizkaia) Spain Lancor SILA_MSYP-160_Manual_v4_ENG.doc Pg. 48 of 48

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

MOUNTING & MAINTENANCE INSTRUCTIONS FOR 9 Pages / Page 1 MOUNTING & MAINTENANCE INSTRUCTIONS FOR THREEPHASE INDUCTION MOTORS - TYPES DM1 / DMA1 / DMA2 TABLE OF CONTENTS page 1 General information 2 2 Delivery 2 3 Mounting 2 4 Coupling 2 4.1.

More information

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9 Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

INSTALLATION MANUAL FOR EVO BRAKES

INSTALLATION MANUAL FOR EVO BRAKES INSTALLATION MANUAL FOR EVO BRAKES DATE OF CREATION: 18/03/2013 DATE OF REVIEW: 13/11/2017 REACH: EVO-01/EVO-05 REVIEW: ES13 1 / 31 ÍNDICE 1 SAFETY INSTRUCTIONS:... 3 1.1 Symbols used:... 3 1.2 General

More information

BAH series Use and Maintenance Manual

BAH series Use and Maintenance Manual Page 1 of 15 BAH 225-280 series Use and Maintenance Manual Page 2 of 15 We would like to thank you for trusting us and buying our product. Field of application Before starting the motor, it s necessary

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

3946 en / a. This manual is to be given to. the end user. HPM x44. A.C. motor. Installation and maintenance

3946 en / a. This manual is to be given to. the end user. HPM x44. A.C. motor. Installation and maintenance This manual is to be given to the end user Installation and maintenance To ensure that the LEROY-SOMER motor you have just purchased is entirely satisfactory, it is essential to adhere to the following

More information

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7 Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other

More information

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

GREENSTAR CANTIELEVER. User Guide. v4 - English

GREENSTAR CANTIELEVER. User Guide. v4 - English GREENSTAR CANTIELEVER User Guide v4 - English Content 1 General Information 1.1 Greenstar 1.2 Objective 1.3 Copyrigth 1.4 Safety 2 Technical Information 2.1 Mounting 2.1.1 Functions 2.1.2 Nomenclature

More information

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive Vacuum Circuit-Breakers, Type HVX 12 24 kv, of cassette design, cassette with motor drive Operating Instructions No. 531 321, Edition 09/00 Table of Contents 1 General 4 1.1 Operating Conditions 4 2 Design,

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

D58 Series Brake Instructions

D58 Series Brake Instructions D58 Series Brake Instructions 4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsbrakes.com Safety information 2 Safety information 2.1 Persons responsible for the safety

More information

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc. Chapter 5 FOUNDATION 1 FOUNDATION - A rigid foundation is essential for minimum vibration and proper alignment between motor and load. Concrete makes the best foundation, particularly for large motors

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

DYNATECH D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM DYNAMICS AND TECHNOLOGY, S.L.

DYNATECH D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM DYNAMICS AND TECHNOLOGY, S.L. DYNATECH DYNAMICS AND TECHNOLOGY, S.L. D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM TABLE OF CONTENTS TABLE OF CONTENTS...- 1-1. INTRODUCTION....- 2-1.1 Description...- 2-2. RISKS AND SECURITY WARNINGS...-

More information

THREE PHASE RECHARGING SYSTEM DIAGNOSIS

THREE PHASE RECHARGING SYSTEM DIAGNOSIS THREE PHASE RECHARGING SYSTEM DIAGNOSIS INDEX 1. Foreword 2. Battery Voltage 3. Recharging System Connections 4. Stator Three Phase Continuity 5. Alternator Phase Insulation 6. Checking Absorption with

More information

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related MV / LV cabins maintenance The operation and maintenance of the cabins are meant to ensure high reliability (i.e. the early detection of anomalies, the failure prevention and monitoring functional) and

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Advanced Hybrid Wind / Solar Charge Controller. User Manual

Advanced Hybrid Wind / Solar Charge Controller. User Manual Advanced Hybrid Wind / Solar Charge Controller User Manual Safety 1. Please read the instructions carefully prior to product use or installation and refer back to them throughout the installation. 2. This

More information

Hollister-Whitney Elevator Corporation

Hollister-Whitney Elevator Corporation Hollister-Whitney Elevator Corporation Installation and Service Manual GL101, GL131, GL171, GL130A, GL185 and GL260 AC Permanent Magnet, Gearless Machines Page 1 of 32 Table of Contents I. Introduction

More information

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev MORATTO S.R.L. Electrical Machinery I 31030 PERO DI BREDA (Treviso) Italy Via A Volta, 2 Tel. +390422904032 fax +39042290363 www. moratto.it - moratto@moratto.it THREE PHASE AND SINGLE PHASE ASYNCHRONOUS

More information

Characteristics of model K brake

Characteristics of model K brake Characteristics of model K brake The brake model K is a spring applied d.c. brake. It has been designed to stop rotational movement of machine shaft. However the user has to ensure that the brake is in

More information

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

Mounting & Maintenance Instructions OMT1 & OMT2 Motors Mounting & Maintenance Instructions OMT1 & OMT2 Motors Seite 1 von 10 Inhalt Seite 1 General information 3 2 Delivery 3 3 Mounting 3 4 Coupling 3 4.1 Direct coupling 3 4.2 Indirect coupling 4 4.2.1 Flat

More information

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._ Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:

More information

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L OPERATION & MAINTENANCE MANUAL 3005/ /12 en Ed. 01 1.2012 SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L CONTENTS 1. SAFETY RULES 1.1. General safety instructions 1.2. Safety precautions 1.3. Intended use

More information

Bi-Directional Progressive Safety Gear

Bi-Directional Progressive Safety Gear Bi-Directional Progressive Safety Gear (PRO 2000-A, PRO 2000-B, PRO 5000) Installation and Operation Instructions PRO 2000-A PRO 2000-B PRO5000 PRODUCT PRO2000-A PRO2000-B PRO5000 Speed, P+Q, [m/s] [kg]

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

ELECTROMAGNETIC DISC BRAKES H2SP SERIES WITH CONSTANT BRAKING TORQUE

ELECTROMAGNETIC DISC BRAKES H2SP SERIES WITH CONSTANT BRAKING TORQUE ELECTROMAGNETIC DISC BRAKES SERIES WITH CONSTANT BRAKING TORQUE K-EN--20151203 TD 223a Spring actuated and electromagnetically released disk brake type powered by direct current. Designed for braking rotating

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/. 1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA Fig.1 Types of mounting GENERAL INFORMATION This manual concerns standard three-phase TEFC induction motors,

More information

Dust cover. Plug. Outlet. Wire pole holder

Dust cover. Plug. Outlet. Wire pole holder Thank you for choosingxtreme machine,baby -Mammoth (4 head), designing with double gear-driving, planetary grinding with four plates. The machine speed can reach 1800 rpm. Aluminum alloy gear box with

More information

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Below, you can see the warning symbols used throughout the manual and their meaning.

Below, you can see the warning symbols used throughout the manual and their meaning. FMI60201 Frameless motors INTRODUCTION FMI-series frameless motors by Rozum Robotics are designed to provide motion as part of a motion system. Available in a range of sizes (dia. 40, 50, 60, 75 mm), FMI

More information

PVL Racing Ignition Installation Instructions

PVL Racing Ignition Installation Instructions PVL Racing Ignition Installation Instructions Fit the ignition coil together with the core sheet package to the chassis frame; additionally, silent blocks may be used to absorb vehicle vibrations and shocks.

More information

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules INSTALLATION MANUAL Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules ING TABLE OF CONTENTS 1. General information 2 1.1 Standards

More information

Focus on Sci. & Tech. Grasp Details

Focus on Sci. & Tech. Grasp Details Focus on Sci. & Tech. Grasp Details B Series Safety brake, adopts modular design and has multiple functions, which can facilitate super rapid response with its professionally designed for low power electromagnetic

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

PATENT PENDING. Phone: (877) Operation and Service Manual

PATENT PENDING.   Phone: (877) Operation and Service Manual PATENT PENDING Phone: (877) 544-2291 Operation and Service Manual 2 IMPORTANT NOTICE This document contains information intended to aid in the proper installation, operation, and maintenance of the product

More information

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS INTRODUCTION FMI-series frameless motors by Rozum Robotics are designed to provide motion as part of a motion system. Available in a range of sizes (stator dia. 41, 51, 75 mm), FMI motors are suitable

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

Heavy duty slurry pumps

Heavy duty slurry pumps USERS MANUAL Heavy duty slurry pumps TOYO PUMPS EUROPE Edition 27.07.2007 SAFETY INSTRUCTIONS TOYO PUMPS EUROPE Users manual for Toyo pumps type «DP..-6 30~40HP» This users manual will help you to maintain

More information

SISTEMA DE CONTROL DEL MOVIMIENTO INCONTROLADO DE LA CABINA UNINTENDED CAR MOVEMENT CONTROL SYSTEM

SISTEMA DE CONTROL DEL MOVIMIENTO INCONTROLADO DE LA CABINA UNINTENDED CAR MOVEMENT CONTROL SYSTEM SISTEMA DE CONTROL DEL MOVIMIENTO INCONTROLADO DE LA CABINA UNINTENDED CAR MOVEMENT CONTROL SYSTEM SYSTÈME DE CONTRÔLE DU MOUVEMENT INCONTRÔLÉ DE LA CABINE KONTROLLSYSTEM FÜR UNBEABSICHTIGTE FAHRKORBBEWEGUNGEN

More information

Z TECHNICAL INSTRUCTIONS

Z TECHNICAL INSTRUCTIONS ÍNDICE: Z40 2.0 TECHNICAL INSTRUCTIONS 1.- Error list 2.- Replace the control board 3.- Opening the machine 4.- Replace the power board 5.- Dismantling motor and gear box 6.- Assembly of gear box 7.- Pushing

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 This manual forms an integral part of the pump and must accompany it until its demolition. The series FMP peristaltic pump is a machine destined

More information

ST Charger. Industrial Battery Charger

ST Charger. Industrial Battery Charger ST Charger Industrial Battery Charger Installation and Operation Manual ST_13 Table of Contents Pg# 1.0 INSTALLATION 1 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage 1 1.4 A.C. Service Requirements 2

More information

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) INTER PLANT STANDARD STEEL INDUSTRY I P S S SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) Corresponding IS does not exist IPSS: 1-10-036-12 0 FOREWORD 0.1 This

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

Electrically Released Brakes ERS VAR10 SZ 5000/5000

Electrically Released Brakes ERS VAR10 SZ 5000/5000 SM366gb - rev 01/06 S E R V I C E Electrically Released Brakes ERS VAR10 SZ 5000/5000 M A N U A L EC type certificate ABV 604/1 according drawing 1 12 106602 WARNER ELECTRIC EUROPE Rue Champfleur, B.P.

More information

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro User s Manual DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro ACMA115 INTRODUCTION Thank you for choosing a PRESIDENT product. You can be sure that the product you have purchased is one of the best that

More information

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03 Table of contents: Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the clutch and any damage may be caused by not observing it. Page 1: - Table of contents

More information

PNEUMATIC CLUTCH-BRAKE SERIE 58

PNEUMATIC CLUTCH-BRAKE SERIE 58 MOUNTING & MAINTENANCE INSTRUCTIONS PNEUMATIC CLUTCH-BRAKE SERIE 58 PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE SETTING UP THE CLUTCH-BRAKE UNIT GOIZPER S. COOP. Antigua, 4 20577 Antzuola (Guipúzcoa)

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11 Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the brake and any damage may be caused by not observing it. Table of contents: Page 1: Page 2: Page 3:

More information

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice INDUCTIVE CONDUCTIVITY SENSOR Instruction Manual Bürkert 00 Subject to technical change without notice INTRODUCTION Table of Contents. INTRODUCTION.... Symbols used.... General safety instructions....

More information

Appendix: Safety and application notes for... 15

Appendix: Safety and application notes for... 15 Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance... 2 Description... 3 Description... 3 Ordering numbers, 380-415

More information

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General SPW TPW6B series SCR Electronic Voltage Stabilizer/Power Conditioner for Industries Use Applications: Printing Specific /Medical Specific /Control Numerical Machine/Elevator Specific /Testing Specific/UPS

More information

MCset kv Medium voltage equipment

MCset kv Medium voltage equipment Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide

More information

Double earth fault in a PSP during back to back launching sequence

Double earth fault in a PSP during back to back launching sequence Double earth fault in a PSP during back to back launching sequence Jean-Louis DROMMI EDF Hydro Engineering Center, France Pump Storage Scheme, back to back launching Electricité de France Hydro Department

More information

Assembly instructions

Assembly instructions Please carefully read the assembly instructions before beginning the installation, operation and maintenance of the solar facility. Noncompliance could cause injury to persons or damage to the equipment.

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Operating & Installation Manual

Operating & Installation Manual Operating & Installation Manual (ZH1.5kw wind turbine system) Company Name:YUEQING ZONHAN WINDPOWER CO.,LTD. Address:NO.195,Chengxi Road,Yuecheng,Yueqing,Zhejiang,P.R.China Zip Code:325600 Tel:86-577-62529820

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

PowerLink JC Series Torque Transducer User Manual

PowerLink JC Series Torque Transducer User Manual PowerLink JC Series Torque Transducer User Manual XiangYi (Hong Kong) Power Testing Instrument Co. Ltd. 0 JC Series Torque Transducer User Manual How to install the sensor properly JC-type torque transmission

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

470 Frame Synchronous AC Permanent Magnet Gearless Motors

470 Frame Synchronous AC Permanent Magnet Gearless Motors 470 Frame Synchronous AC Permanent Magnet Gearless Motors AC Gearless Machines Imperial Alternating Current, Permanent Magnet, Gearless Machines are available in three frame sizes to suit a wide range

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection.

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection. GeN2 Comfort lift A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection. Using a unique polyurethane-coated steel belt drive system - a revolutionary

More information

Electric motor testing

Electric motor testing Electric motor testing MOTOR (MODELS EJ4-4001 AND EJ8-4001A) 23 GENERAL INFORMATION The vehicle is equipped with a 48-volt DC, shunt-wound, reversible traction motor. The shunt-wound motor is designed

More information

AUTOGARD SERIES 820 TORQUE LIMITER Installation and Maintenance Manual DB0009 Issue 11 21 Feb 2017 British Autogard Ltd 2 Wilkinson Rd., Love Lane Industrial Estate, Cirencester, Glos., GL7 1YT UK Tel.

More information

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294 DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO. 897076 620 SRM 294 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure all slings, chains, or cables are correctly

More information

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user Réf. 3483 GB - 4.33/a - 09.2001 This manual is to be given to the end user PV4 - PIV6 Submersible multistage centrifugal Installation and maintenance PV4 - PIV6 1 - GENERAL PV4 and PIV6 series should be

More information

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2 Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand ( July 14-18, 2007) Lecture on L33-2 By S.N.Singh Senior Scientific officer ALTERNATE HYDRO

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB ACTUATOR CLASSE I TYPE MA, MB CONTENTS Page : 2/13 PRODUCT DESCRIPTION General description 3 Product specification 5 INSTALLATION Storage 6 Unpacking 7 Handling 7 Installation : Mechanical 7 Installation

More information

INSTALLER MANUAL USER MANUAL. Contents

INSTALLER MANUAL USER MANUAL. Contents Installation & user manual two way Contents INSTALLER MANUAL Important information General 1. Technical data 2. Description Installation: 1. Positioning the unit 2. Connection. 3. Parts description. 4.

More information

ELECTRICAL. Contents - Wiring Diagrams

ELECTRICAL. Contents - Wiring Diagrams Contents - Wiring Diagrams T-Bar (Floating Deck - Hydro)............................................ 8-16 T-Bar (Fixed Deck - Gear)............................................... 8-17 T-Bar (Fixed Deck

More information

Heavy duty slurry pumps

Heavy duty slurry pumps USER S MANUAL Heavy duty slurry pumps TOYO PUMPS EUROPE Edition 27.07.2007 SAFETY INSTRUCTIONS TOYO PUMPS EUROPE User s manual for Toyo pumps type «GR..-2 3~10HP» This user s manual will help you to maintain

More information

DELPHI THREE PHASE MOTORS

DELPHI THREE PHASE MOTORS DELPHI THREE PHASE MOTORS Technical manual Technical Manual delphi series motors rev. 06 Page 1 OF 19 Technical characteristics Rotomotive motors are built according to international standard regulations

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Installation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _.

Installation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _. Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents: Page

More information

/ S. Warhawk Road, Conifer, CO /

/ S. Warhawk Road, Conifer, CO / www.turnstiles.us www.turnstiles.us / www.entrapass.com 8641 S. Warhawk Road, Conifer, CO 80421 / 303-670-1099 TABLE OF CONTENTS 1 DIRECTIONS... 3 2 INTRODUCTION... 3 3 CATRAX CLIP CHARACTERISTICS... 4

More information

Lenze spring applied brakes

Lenze spring applied brakes Type BFK 458 N Spring applied, electromagnetic release Factory preset torque Simple, quick assembly Adjustable for wear Very robust Torques 2 to 600 Nm S1 continuous rated Static and dynamic braking No

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved DR310 TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DR310 is an allelectronic voltage and current regulator for dynamos

More information

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT Quadri di Manovra per Ascensori Lifts Control Panels PELAZZA PEPPINO S.r.l. 20063 CERNUSCO SUL NAVIGLIO (MI) ITALY Via Ponchielli, 6/8 Tel. 02/92.31.694 Fax 02/92.42.706 Tel. 02/92.42.706 Web Site: www.pelazza.com

More information

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy* 6.0 SPECIFICATIONS Calibration According to factory procedureeeeeeeeeeeeeee Accuracy* ± 1% full scale (FS) or ± 1 graduation on scale Scale diameter 41 mm Temperature range 45 to 115 F (10-45 C) Air humidity

More information

EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07

EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07 EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07 When properly installed, operated and maintained, this equipment will provide a lifetime of optimum operation. It is mandatory that the person

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DWP & Submersible pumps type LANDY DNP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

Surepowr Series Sure 150

Surepowr Series Sure 150 RCS Acutators Surepowr Series Sure 50 Installation Manual Safety First In the maintenance and operation of mechanical equipment, safety is the basic factor which must be considered at all times. Through

More information