Metal Position Switch Series 8074
|
|
- Tamsyn Malone
- 5 years ago
- Views:
Transcription
1 > Dimensions and characteristic values according to EN > Replaceable contact element in flameproof enclosure > Positive opening contacts > Wide range of actuators > All actuators can be displaced by 4 x 90 > Contact element with low-action contact or overlapping low-action contact > Largely oil- und petrol-resistant E00 Position switches are used to monitor the position of moving parts of machines and systems. The robust zinc die-cast enclosure resists mechanical load and is suitable, among others, for ensuring safety in elevator construction, conveyor technology and in mechanical and plant engineering. may be used in safety circuits as the devices fulfill IEC/EN and the contacts are positive opening. For this series, a belt-alignment position switch is also available. This switch, which uses a length-adjustable lever with nylon reel as actuator element, monitors the conveyor belt run. If the conveyor becomes misaligned, the lever is actuated, resulting in a safety signal switching off the conveyor. ATEX Zone For use in x x x x WebCode 8074A Control Devices /1
2 Selection Table Version Actuator Contact element Order number Weight 10787E E E E E E00 Extended plunger Roller plunger Roller lever plunger Swivelling roller lever Adjustable roller lever Actuating rod Spring rod Plunger of stainless steel ; rod of stainless steel Rod of Spring of stainless steel kg 8074/1-1-S /1-3-S /1-5-S /1-1-RS /1-3-RS /1-5-RS /1-1-AR /1-3-AR /1-5-AR /1-1-HR /1-3-HR /1-5-HR /1-1-HV /1-3-HV /1-5-HV /1-1-HH-K /1-3-HH-K /1-5-HH-K /1-1-F /1-3-F E E00 Big swivelling lever 8074/1-1-HR /1-3-HR /1-5-HR /2 Control Devices
3 Selection Table Version Actuator Contact element Order number Weight kg 8074/1-1-BSS Belt-alignment switch 10780E00 Forked roller lever 8074/1-1-GR /1-3-GR E E E00 Angled roller lever 8074/1-1-WR /1-3-WR /1-5-WR Safety switch Separate actuator 8074/1-1-ZB /1-3-ZB Note: Actuators for the safety switch have to be ordered separately. Straight actuator Angled actuator Adjustable actuator Explosion Protection Explosion protection Europe (ATEX) Gas and dust BVS 05 ATEX E 007 E II 2 G Ex d e IIC T6 (Ta = C) E II 2 G Ex d e IIC T5 (Ta = C) E II 2 D Ex td A21 IP67 T95 C (Ta = C) E II 2 D Ex td A21 IP67 T80 C (Ta = C) Certificates and approvals Certificates ATEX, Kazahkstan (GOST-K), Russia (GOST-R), Belarus (GOST-B) Technical Data Electrical data Electrical load Min. electrical load Max. electrical load 24 V AC / DC, 10 ma AC-15: 250 V AC, 6 A DC-13: 230 V DC, 0.25 A 6 A (time-lag) Back-up fuse Ambient conditions Ambient temperature see explosion protection data Mechanical data Degree of protection IP67 according to IEC/EN Material Enclosure Zinc die cast, coated Contacts Silver Service life max operations *) max operations/h *) Replace contact element after max operations Connection M3 screw type terminal, max. 1.5 mm Control Devices /3
4 Technical Data Mounting / Installation Cable glands 8161: 1 x M20 x 1.5 Cable dia. range mm Contact Version 8074/ / / Circuit diagram Switching path 10826E E E00 Switching function 1 NC + 1 NO 10829E E E NC + 1 NO, overlapping E E Positive opening contacts according to IEC/EN E00 Accessories and Spare Parts Designation Illustration Art. no. Weight kg Contact block 1 NC + 1 NO 8084/1-1 S/Ö /1-3 2Ö E00 1 NC + 1 NO overlapping 8084/1-5 S/Ö UE Actuator Straight E00 Angled E00 Adjustable E00 Cable gland M20 x /5-M E00 /4 Control Devices
5 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 8074/1-.-S Extended plunger 10752E E E /1-.-RS Roller plunger 8074/1-.-AR Roller lever plunger 8074/1-.-HR312 Big swivelling lever 10759E E E /1-.-HV Adjustable roller lever 8074/1-.-F2 Spring rod actuator 8074/1-.-HH-K Actuating rod 10757E E E /1-.-WR Angled roller lever 8074/1-.-HR311 Swivelling roller lever Control Devices /5
6 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 8074/1-.-BSS Belt-alignment switch 10760E E E /1-.-GR Forked roller lever Safety switch Straight actuator; for safety switch 10817E E E00 Angled actuator; for safety switch Adjustable actuator; for safety switch We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice.the illustrations cannot be considered binding. /6 Control Devices
Position Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationTank Inspection Lights Series 6122
> For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationLoad and Motor Switches, Load-Break Switches Series 8549
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationControl Buttons Series 8082
www.stahl.de > Contact element with 1 NO contact 1 NC contact, positive opening > Contact material silver-nickel or gold-plated > 9 different actuators Push Mushroom push Selector switch Rotary actuator
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEx UPS standard Series 8265
> Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationFloodlight Series 6521/4
> The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationTerminal Boxes Series 8252/1
www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationFloor and fine adjustment switches
Floor and fine adjustment switches 6 Introduction 6-2 AS 1 6-3 ASH 2 6-4 AFH 2 6-5 Reference table technical data 6-6 Universal switches 6-7 Floor and fine adjustment switches / Introduction ➀ ➁ ➂ Floor
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationDP_T Limit Switches. Double Insulation Plastic Casing IP65-50 mm. width. T1 - Plain plunger T10: nylon plunger T11: metal plunger 0,5 15 /
DP: two cable inlets for M16 x Cable Gland DP5: two cable inlets for M2 x Cable Gland Plastic Casing IP65-5 mm. width T1 - Plain plunger T1: nylon plunger T11: metal plunger T1 - Roller plunger T12: metal
More informationRecommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.
Metal-Enclosed Limit Switches ENM2 Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Product advantages Standard switch
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationPortable Lamps Series HS6145, HSL145
www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use
More informationControl Device System NEC Series ConSig 8040
16113E00 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions >
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More information4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)
4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are
More informationE II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc
900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationSafety switches / Position switches / Command devices
Safety switches / Position switches / Command devices SAFE SWITCHGEAR FOR DEMANDING AND CRITICAL APPLICATIONS // Control technology / Catalogue 4 The Company PRODUCTS 8 Safety switches with separate actuator
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationTIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type)
TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type) Introduction Electrohydraulic-acting Spring-return rotary actuator 90
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationResistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L
Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More informationThermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L
Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry
More informationPRECISION SWITCHES CONTENTS
PRECISION SWITCHES CONTENTS Limit Switches to EN50041 LIMIT SWITCHES The TEKNIC Limit Switch Precision, Reliability and Versatility. The TEKNIC Limit switch is a versatile unit, according to the EUROPEAN
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More informationLimit Switches AT0 - Features
AT0 - Features 06/005 High Control Circuit Reliability with Universal s With low control circuit voltage, an increased number of circuit failures can occur in electrical control systems. That is the reason
More information10 Load and Motor Switchgear
0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationGeneral spare parts. Accessories & Spare parts. Ordering information. SPB03: Battery with retrofit battery clamp (XX) Lithium 3xAA-Cell batteries
General spare parts Lithium 3xAA-Cell batteries SPB03: Battery with retrofit battery clamp (XX) SPB02 SPC02 Retrofit instruction video SPC03: Battery with retrofit battery clamp (XI) Retrofit instruction
More informationResistance thermometer Without thermowell Model TR10-H
Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationResistance thermometer Model TR10-L, Ex d, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 Applications Sensor for continuous level measurement of liquids in bypass level indicators Chemical and petrochemical
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationGross Automation (877)
Limit Switches Carlo Gavazzi broadens its leading range of products for the industrial automation world, with the new and complete range of mechanical limit and safety switches. These robust switches provide
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationArmoured / Un-armoured Cable Gland
Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance
More informationMeasuring insert for process resistance thermometer
Electrical temperature measurement Measuring insert for process resistance thermometer Model TR12-A WIKA data sheet TE 60.16 for further approvals see page 2 Applications Replacement measuring insert for
More informationControl and Terminal Box Type A21-**-*****
e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationApparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components
E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More information