NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

Size: px
Start display at page:

Download "NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING"

Transcription

1 NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

2 NOUVEAULINE EC DESIGN AIR CURTAIN Steel-composite design high-quality powder coated Inspection panel hinged on one side, opens downwards in combination with the intake grille Patented Jetflow nozzle for optimised shielding performance Applications Nouveauline EC is the attractively-designed model for the sophisticated entry area. It is used in shops and retail, banks and architecturally significant façade areas. Nouveauline EC fulfils the requirements of these wherever energy-efficient solutions meet high-quality design. Installation-ready, -hanging unit. Special design To save energy, the Nouveauline EC has been equipped with the new, optimised Jetflow discharge nozzle. This patented discharge nozzle is characterised by the multi-adjustable discharge angle and its adaptive, asymmetrical nozzle cross-section. Thanks to the specially selected asymmetrical adjustment of the Jetflow air guide profiles, not only is the level of noise reduced, but a larger throw distance is achieved, thus optimising the shielding performance. The housing Self-supporting steel-composite construction used for the air blower housing. Screws are not visible. High-quality powder coating, RAL 9006 as standard (white aluminium). Other colours are available. Inspection panel opens downwards in combination with the intake grille. Attractive intake grille D stainless steel finely perforated plate with micro grille behind it for filterless, easy maintenance application. Acoustically and thermally insulating lining. Heating media Heat exchangers for different heating media LPHW: for normal temperature LPHW 70/50 C and low-temperature LPHW 60/40 C, other temperatures available on request. DX: DX register soldered under nitrogen for operation with heat pumps (only heating modus possible). High-quality heat exchanger made from copper tubes, with pressed-on, extra-strong aluminium fins. ELECTRO: -stage heat exchanger 400V, spiral form, corrosion resistant, with thermal overheating protection and switch-off delay.

3 Attractive intake grille with micro-intake grille behind it Advantages at a glance Made in Germany ErP 015 ready / EC fans Certified by TÜV-Süd Self-supporting steel-composite construction Individual colours available (standard RAL 9006) Patented energy-saving Jetflow nozzle Individual unit lengths up to 500 mm Service-friendly thanks to filterless micro-intake grille Simple to install Higher throw distances thanks to optimised technology Different heating media possible EC fans The efficiency of the EC fans used by TEKADOOR is > 90% under partial load operation. This is 0 5% higher than for conventional AC fans. This does not just increase the efficiency, but also reduces the operating costs. The individually-driven EC fans with integrated motor protection can intake air in both directions. They have vibration- bearings and are controlled with 0-10 V. They do not just comply with Directive ErP015, but actually exceed this standard. We recommend our suspended cladding to cover the supply lines. Mounting Simple mounting thanks to the rivet nuts (M) incorporated on the upper side of the unit and ly-available assembly materials. In the standard version, the unit does not need to be opened for electrical connection. Connection terminals for the voltage supply, as well as the connectors for the control unit and parallel operation can be accessed from the outside. Maintenance Easy to clean (micro grille) without opening the unit by simply vacuuming the intake grille. Secured inspection panel (hinges on one side) easy to open for maintenance work, in combination with the intake grille. Control Electronic TEKADOOR GTM EC control unit, multifunctional, among others with ModBus interface A GTM EC control unit is used as standard for units with LPHW heating. For units with electrical heating, a GTM 1 E EC control unit is used. Both come with 0 m preassembled and shielded data cable. The GTM EC 5-stage control unit includes the ability to switch from manual to automatic and from summer mode to winter mode as standard. A solenoid valve of up to.5 A can be connected as an option for the winter mode. With the standard GTM 1 E EC control unit, the airflow can be selected manually in 5 stages and the heating capacity depending on the fan level can be selected manually in stages. Both control units have a potential- contact for enabling via any on-site BMS or BEMS. A maximum of 10 units can be connected in parallel.

4 NOUVEAULINE EC DETAILS Connections Heating connections flow and return on top of the unit as standard for easy connection to the on-site heating system. (Internal thread dimensions depend on the model) Connection box (LPHW) Simple electrical connection via connection box (voltage supply 0 V/50 Hz on the top of the unit). Exception: Electrical units with a heating capacity greater than.5 kw. 4

5 Data cable connection/interface Simple, standard plug and play connection of the data cable and an solenoid valve on the top of the unit. The connection can be offset on request. Control: Input for the data cable to the control unit. Jetflow discharge nozzle Jetflow discharge nozzle with adaptive, asymmetrical nozzle cross-section. The special design of this patented discharge nozzle permits stepless variation of the discharge angle combined with a longer guided, smooth air stream with optimum throw distance. Auxiliary: Output for parallel operation with other units. 5

6 NOUVEAULINE EC FREE-HANGING INSTALLATION NOUVEAU 6

7 IN OUT TOP VIEW Seitenansicht/Schnitt SIDE VIEW/SECTION IN OUT Ansaugseite A Ansaugseite Seitenansicht/Schnitt Ansaugseite 7 Jetflowdüse FRONT VIEW 55 A A = variable Länge Jetflowdüse technische Änderungen vorbehalten BOTTOM VIEW gezeichnet geändert Name ma Datum Werkstoff Maßs 10 Albert-Einstein-Str. 11 D Langenfeld Tel.: 049 (0) Fax: 049 (0) A = variable Länge Kundenzeichnung Nr.: Benennung Kunde Pos. von Gruppe Erstelldatum Nouveauline Jetflow 106 Teile Blatt 1 von technische Änderung gezeichnet Name ma Datum geändert Werkstoff Pos. von Grupp Kundenzeichnung Nr.: Erstelldatum A = VARIABLE UNIT LENGTH Benennung Albert-Einstein-Str. 11 Nouveauline Jetflow 10 D Langenfeld * WE RESERVE THE RIGHT TO MAKE Kunde TECHNICAL CHANGES Tel.: 049 (0) Fax: 049 (0) Connection-ready -hanging door air curtain unit for visible installation directly above the door. Ambient air intake is at the front, on the room side. LINE EC7

8 NOUVEAULINE EC STANDARD CIRCUIT DIAGRAM FOR LPHW Hand Fr ModBus interface () Stufe MODE 1 4 ext. Contact Raumthermostat 1 MOD Bus Adresse to input CONTROL next PCB Standard supplied shielded datacable (0 m) 1:1 straight wired RJ 45 connentors! Magnetic valve (OPTIONAL) L N PE 1 M next Fan MOD Bus RJ 45 ON 1 AUX AUXILIAR MON CONTROL PCB EC L N PE 0V / 50Hz L N PE intern 4 weiss/white gelb/yellow blau/blue rot/red L1 N PE imp. Y 0-10 V 0 V 10 V zum Steuerteil (CONTROL) Adresse 1-9 Standard Anschlusskabel (0 m) mit RJ-45 Stecker Magnetventil (OPTIONAL) CPU AUXILIAR CONTROL Adress switch 0 = MASTER 1-9 = SLAVE F 16 AT AUX MON BMS On/Off Frost protection thermostat ext. Contact Room Termostat Failure Operation L N PE Connecting box Mains switch and fuses to be installed by third parties must comply to all applicable ruls and 0V/ 50Hz requirements! CPU Adress Schalter 0 = MASTER 1-9 = SLAVE Plati * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES GTM EC control unit with ModBus interface languages can be selected (German/English), menu-prompted electronic control for air curtains with energy-saving EC fans and LPHW heating. Operation/navigation is performed with a central rotary multiselector. Menu operation via.4" colour display with text and icon display for different operating states. Standard display of the date and time. Multiple operating modes possible: 1.) Manual.) AutoTK = Automatic operation with door contact control (adjustable switch-off delay time sec).) AutoTK = Automatic operation with door contact control and room thermostat 4.) AutoTA = Automatic operation with cool down protection and door contact control Functions: Manual-automatic modes, 5 stage, summer/winter modes, adjustable switch-off delay time, frost protection. Inputs: Room thermostat (cool down protection), door contact (external signal encoder), frost protection thermostat, enable contact via external BMS or BEMS. Outputs: potential- operation and malfunction signal Notifications are displayed with an orange background and faults with a red background! Thanks to different coding of the control boards (Master/Slave) up to 10 door air curtains Name can be connected Datum in parallel gezeichnet/signet la with 1 control unit. Load and control boards preinstalled in the door air curtain unit and 0 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard. DDC- Freigabe nicht belegt Frostschutzthermostat ext. Signalgeber nicht belegt nicht belegt Werkstoff nicht belegt

9 NOUVEAULINE EC CIRCUIT DIAGRAM FOR ELECTRICAL HEAT EXCHANGER Hand Fr Stufe 4 1 Room thermostat ModBus interface () MODE K1 K K 1 MOD Bus Adresse to input CONTROL next PCB AUX AUXILIAR Standard supplied shielded datacable (0 m) 1:1 straight wired RJ-45 Stecker q S 0 MON CPU CONTROL K1 q S 60 K1 q S 45 Adress switch 0 = MASTER 1-9 = SLAVE q S 50 PCB EC L N PE 0V / 50Hz L N PE intern q S M weiss/white gelb/yellow blau/blue rot/red F 16 AT next FAn L1 N PE Y 0-10 V 0 V 10 V imp. zum Steuerteil (CONTROL) Adresse 1-9 AUX AUXILIAR MOD Bus RJ 45 MON CONTROL ON 1 Standard Anschlusskabel (0 m) mit RJ-45 Stecker Magnetventil (OPTIONAL) BMS On/Off Room thermostat Failure Operation K0 1 L N PE Connecting box Plati K K step step 1 step = step 1 step 4 ~400V/ 50Hz 0V/ 50Hz Mains switch and fuses to be installed by third parties must comply to all applicable rules and requirements! CPU Adress Schalter 0 = MASTER 1-9 = SLAVE * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES GTM 1 E EC control unit with ModBus interface languages can be selected (German/English), menu-prompted electronic standard control for air curtains with energy-saving EC motors and electrical heating. Operation/navigation is performed with a central rotary multi-selector. Menu operation via.4" colour display with text and icon display for different operating states. Functions: Manual switching of 5 fan levels and heating levels. Inputs: Enable contact via on-site BMS or BEMS, room thermostat, (On/Off: only for electrical heating). Outputs: potential- operation and malfunction signal. Notifications are displayed with an orange background and faults with a red background! Thanks to different coding of the control boards (Master/Slave) up to 10 door air curtains can be connected in parallel with 1 control unit. Load and control boards preinstalled in the door air curtain unit and 0 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard. DDC- Freigabe nicht belegt Frostschutzthermostat ext. Signalgeber nicht belegt nicht belegt nicht belegt gezeichnet/signet Name la Datum Werkstoff

10 NOUVEAULINE EC OPTIONAL ACCESSORIES Thermostatic straightway valve (Setting range 5 C to 45 C) limits the discharge temperature (constant supply air temperature limitation). Also available as a -way valve. Ceiling attachment set For problem-, vibration- ceiling attachment, consisting of M threaded rods, up to 1000 mm length, vibration dampers, turn-buckles and counter nuts. Door contact solenoid switch In automatic mode switches on the door air curtain in the preselected stage in conjunction with GTM EC, GTM EC and GTM E EC. 10

11 Frost protection thermostat Solenoid valve Room thermostat Thermo-electric shut-off valve For monitoring LPHW heat exchangers exposed to the risk of frost. As soon as the temperature falls below 7 C, the fans are switched off and an solenoid valve is opened. Opens or closes the heating water circuit in the summer/ winter setting of the control unit, to close the heating water circuit during summer operation or when the air curtain is not working (normally closed). Prevents overheating or overcooling of the room/ vestibule in automatic operation. 0 V / 50 Hz, normally closed. On-site installation in the heating flow. Actuation via the summer/ winter circuit. Summer function closed. Winter function open. Caution: If solenoid valves or thermoelectric shut-off valves are used, it is expressly recommended to install a frost protection thermostat (automatically actuated) and a strainer. 11

12 NOUVEAULINE M EC TECHNICAL DATA FREE-HANGING Design based on: recommended operating point intake temperature tle = 0 C discharge temperature tla = 4 C discharge height = up to.70 m MODEL M 1 M 1.5 M M.5 Air quantity max. m /h Heating capacity rated 1 LPHW 70 / 50 C kw LPHW 60 / 40 C kw Flow rate LPHW 70 / 50 C m /h LPHW 60 / 40 C m /h Water resistance LPHW 70 / 50 C kpa LPHW 60 / 40 C kpa Nominal connection sizes Internal thread Inches x /4" x /4" x /4" x /4" Flow/return DN EC fans Voltage V 0 / 1 / N / PE Frequency Hz 50 Current consumption A Motor power kw Electric heater -stage Voltage V 400 / / N / PE Frequency Hz 50 Heating capacity kw /6/9 4//1 6/1/1 6/1/1 Sound pressure level Highest setting db (A) Drawing dimension Unit width ( A ) mm Unit height mm Unit depth mm Weight kg * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended.. Measured at a lateral distance of m. Sound pressure level may very depending on surrounding conditions.. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 1

13 NOUVEAULINE L EC TECHNICAL DATA FREE-HANGING Design based on: recommended operating point intake temperature tle = 0 C discharge temperature tla = 4 C discharge height = up to.00 m MODEL L 1 L 1.5 L L.5 Air quantity max. m /h Heating capacity rated 1 LPHW 70 / 50 C kw LPHW 60 / 40 C kw Flow rate LPHW 70 / 50 C m /h LPHW 60 / 40 C m /h Water resistance LPHW 70 / 50 C kpa LPHW 60 / 40 C kpa Nominal connection sizes Internal thread Inches x /4" x /4" x /4" x /4" Flow/return DN EC fans Voltage V 0 / 1 / N / PE Frequency Hz 50 Current consumption A Motor power kw Electric heater -stage Voltage V 400 / / N / PE Frequency Hz 50 Heating capacity kw 5/10/15 7.5/15/.5 10/0/0 10.7/1.4/ Sound pressure level Highest setting db (A) Drawing dimension Unit width ( A ) mm Unit height mm Unit depth mm Weight kg * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended.. Measured at a lateral distance of m. Sound pressure level may very depending on surrounding conditions.. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 1

14 NOUVEAULINE DX-H M EC TECHNICAL DATA FREE-HANGING ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tle = 0 C discharge temperature tla = 4 C discharge height = up to.70 m heating gas temperature = 70 C condensation temperature = 50 C condensate exit temp. = 45 C operating pressure = max. 45 bar MODEL DX-H M 1 DX-H M 1.5 DX-H M DX-H M.5 Air quantity max. m /h Power rated 1 DX heating capacity kw Delivery and intake line Connections mm 10/16 10/16 10/1 10/ EC fans Voltage V 0 / 1 / N / PE Frequency Hz 50 Max. current consumption A Max. motor power kw Sound pressure level Highest setting db (A) Drawing dimension Unit width ( A ) mm Unit height mm Unit depth mm Weight kg * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above).. Measured at a lateral distance of m. Sound pressure level may very depending on surrounding conditions.. Control voltage 0-10 V A well-balanced pressure ratio is one of the prerequisites for perfect function. 14

15 NOUVEAULINE DX-H L EC TECHNICAL DATA FREE-HANGING ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tle = 0 C discharge temperature tla = 4 C discharge height = up to.00 m heating gas temperature = 70 C condensation temperature = 50 C condensate exit temp. = 45 C operating pressure = max. 45 bar MODEL DX-H L 1 DX-H L 1.5 DX-H L DX-H L.5 Air quantity max. m /h Power rated 1 DX heating capacity kw Delivery and intake line Connections mm 10/16 10/1 10/ 10/ EC fans Voltage V 0 / 1 / N / PE Frequency Hz 50 Max. current consumption A Max. motor power kw Sound pressure level Highest setting db (A) Drawing dimension Unit width ( A ) mm Unit height mm Unit depth mm Weight kg * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above).. Measured at a lateral distance of m. Sound pressure level may very depending on surrounding conditions.. Control voltage 0-10 V A well-balanced pressure ratio is one of the prerequisites for perfect function. 15

16 German headquarters TEKADOOR GmbH Albert-Einstein-Str. 11 D Langenfeld T. 49 (0) F. 49 (0) E. A =

WING WING-R WING WING-R WING-G WING-G WING-R EC & WING-G EC DESIGN AIR CURTAIN FOR VERTICAL INSTALLATION INDIVIDUAL INNOVATIVE ENERGY-SAVING

WING WING-R WING WING-R WING-G WING-G WING-R EC & WING-G EC DESIGN AIR CURTAIN FOR VERTICAL INSTALLATION INDIVIDUAL INNOVATIVE ENERGY-SAVING WING WING-R WING WING-G WING-R WING-G WING-R EC & WING-G EC DESIGN AIR CURTAIN FOR VERTICAL INSTALLATION INDIVIDUAL INNOVATIVE ENERGY-SAVING WING-R EC DESIGN AIR CURTAIN Jetflow discharge nozzle patented,

More information

COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING COLUM EC DESIGN AIR CURTAIN Aluminium profile discharge fins (drop form) for optimum airflow

More information

RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC FOR REVOLVING AND CURVED SLIDING DOORS INDIVIDUAL INNOVATIVE ENERGY-SAVING

RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC FOR REVOLVING AND CURVED SLIDING DOORS INDIVIDUAL INNOVATIVE ENERGY-SAVING FOR REVOLVING AND CURVED SLIDING DOORS INDIVIDUAL INNOVATIVE ENERGY-SAVING + Self-supporting, industrially-galvanised sheet steel housing powder-coated on request + Heating connections at the side (left

More information

COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING DESIGN AIR CURTAIN Aluminium profile discharge fins (drop form) for optimum airflow Elegant steel-composite design high-quality powder coated or with

More information

CassetteEffect EC. Recessed air curtain

CassetteEffect EC. Recessed air curtain Recessed air curtain Type S/M/G Standard lengths Installation The is specially designed for recessed mounting in a (false) ceiling. Installation friendly mounting strips can be found on top of the air

More information

Features: Available in horizontal and vertical units

Features: Available in horizontal and vertical units Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements

More information

Comfort Door Air Curtains. Li, Li EC.

Comfort Door Air Curtains. Li, Li EC. Comfort Door Air Curtains Li, Li EC www.stavoklima.eu Door Air Curtains Li Content Content: Selection of the air curtain...page 4 Air Curtains Li with static and dynamic advertising panel...page 5 Technical

More information

IDENTIFICATION ACCESSORIES DESCRIPTION

IDENTIFICATION ACCESSORIES DESCRIPTION Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1 IDENTIFICATION

More information

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Air Curtains for Revolving Doors

Air Curtains for Revolving Doors Air Curtains for Revolving Doors Air curtains for revolving doors ROTOWIND The design of buildings with revolving doors that integrate with the environment is a common solution when the entrance has adverse

More information

New standard decorative generation

New standard decorative generation SMART Air Curtain SMART New standard decorative generation Based on the range of standard WINDBOX series and incorporating the contemporary elegance and rounded shapes of DECO air curtains, it comes the

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

Toshiba EMEA. 14 th June 2012

Toshiba EMEA. 14 th June 2012 Toshiba EMEA Light Commercial Air Curtain 14 th June 2012 1 Toshiba LC DX Air Curtain Application: building and shop entrances Operating modes: Heating and fan only (Cooling not permitted) Ex-factory date:

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate separation

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,

More information

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h SysCoil Fan Coil Units Models SVC, SVN, SHC, SHN 0.79 to 8.75kW 0.49 to 4.90kW 94 to 930 3 /h SysCoil Quality, efficiency and reliability Vertical console units with cabinet, SVC type SVC vertical console

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL

More information

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple

More information

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3 Technical Catalogue Cassette Fan Coils Climmy Comfort 3 CONTENTS INTRODUCTION Version Fan Coil Page 3 Page 4 Page 6 Page 7 Page 8 Page 12 Page 13 Page 15 Page 16 Page 18 Page 19 Page 20 Page 22 -ECM Version

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain Revolutionary climate separation The SensAir comfort air curtain sets a new standard in the field of climate separation. The highest level of comfort

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents Residential HEE motor Silent operation Heating capacity: 200 W to 4 kw Cooling capacity: 100 W to 3 kw Operation is CIAT's residential. This vertical cased unit, designed for heating and cooling, is available

More information

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X Date: 08.06.2018 Price: 13121 EUR without VAT, W Vilnius Air handling unit model: VERSO-CF-30-2.6-H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

8/S3 8/S1 AIR CURTAINS AIR CURTAINS SONATA, SONATA-V SONATA, SONATA-V. v 3.1 (en) v 1.0 (en) Design changes reserved

8/S3 8/S1 AIR CURTAINS AIR CURTAINS SONATA, SONATA-V SONATA, SONATA-V. v 3.1 (en) v 1.0 (en)  Design changes reserved 8/S3 8/S1 v 3.1 (en) v 1.0 (en) AIR CURTAINS SONATA, SONATA-V AIR CURTAINS SONATA, SONATA-V PB 4 www.klimaoprema.hr 1 425 AIR CURTAIN SONATA TABLE OF CONTENTS Air curtain Sonata No 4273 Technical characteristics

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Total cooling capacity kw Total heating capacity kw Features

Total cooling capacity kw Total heating capacity kw Features Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design

More information

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains Compliant with ERP 015 Regulation (EU) No. 7/011 Cert. n 0545 Heating Door Curtains The range of SBIN door curtains offers imum flexibility in the protection of doors and open access compartments. By connecting

More information

TTL-TREND -10/15/LNX Energy saving air curtain systems with EC-fan technology

TTL-TREND -10/15/LNX Energy saving air curtain systems with EC-fan technology TTL Products Comfort TTL-TREND -10/15/LNX Energy saving air curtain systems with EC-fan technology TTL-TREND Door air curtain - against cold and draft with proven technology Vario connection block TTl

More information

Heat Exchangers. Evaporator Catalogue

Heat Exchangers. Evaporator Catalogue Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted

More information

TTL-TREND -5/8/LNS/HE Energy saving air curtain systems with EC-fan technology

TTL-TREND -5/8/LNS/HE Energy saving air curtain systems with EC-fan technology TTL Products Comfort TTL-TREND -5/8/LNS/HE Energy saving air curtain systems with EC-fan technology TTL-TREND Door air curtain - against cold and draft with proven technology Vario connection block TTl

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

MOBILAIR M 20. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 2.0 m³/min (71 cfm)

MOBILAIR M 20. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 2.0 m³/min (71 cfm) MOBILAIR M 20 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 2.0 m³/min (71 cfm) www.kaeser.com MOBILAIR M 20 Lightweight Quiet Powerful The perfect energy-saving combination: a Kubota

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC 0435 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Functions Technical information - Actuator 24 V. Features. General information. lindab we simplify construction

Functions Technical information - Actuator 24 V. Features. General information. lindab we simplify construction Actuator 24V Scope of supply (standard) 1x Actuator 24 V 1x Connection cable in white, 1 m, Hal F H03Z1Z1 1x installation manual with 12 languages Standard Version: A 40405: 24 V normally closed (NC) Alternative

More information

Linear Valve Electric Actuator

Linear Valve Electric Actuator Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest

More information

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor Maestro High Pressure Fan Coil Unit with Asynchronous Motor The Maestro high pressure fan coils are produced in 5 sizes. Designed and built for concealed installations, they have small dimensions, are

More information

Air curtain.

Air curtain. Air curtain www.wingbyvts.com 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 WING 2.1 WING air curtains 2.2 Silence and power 2.3 Design and performance 2.4 Quality

More information

INSTRUCTION MANUAL. Air Curtains Rund (M, G)

INSTRUCTION MANUAL. Air Curtains Rund (M, G) INSTRUCTION MANUAL Air Curtains Rund (M, G) SECURITY ADVISE SIMBOLS Attention, Danger, Safety Advice! Danger from electric current of high voltage! Injuries risk! Danger! Do not step underneath: Heavy

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units Chiller Close Control Water terminals SYSCASSETTE Water cassette units SYSCASSETTE Water cassette Available accessories Available in 8 different sizes and 2 versions. Due to its square design these units

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

(UK) Date : January 2014

(UK)   Date : January 2014 Sentinel Door Curtain - Model 270 Installation, Operation & Maintenance Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430 Trench Heating/Cooling Katherm HK Tested acc. to: BS EN 16430 Improved performance The narrower trench width and shallower trench height of the totally redesigned Katherm HK delivers an optimised output

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide January 2002 Systempac Features and Design Guide Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box

More information

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7 EBL 99 C, Art.-Nr. 911.413 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

Innovative, High Performance, Quiet Units.

Innovative, High Performance, Quiet Units. Fan Coil Units Innovative, High Performance, Quiet Units. Technical Brochure TM AQF-A.4GB Date : January 2006 Supersedes : TM AQF-A.3GB/04.04 Quality, efficiency and reliability, built into every unit...

More information

VRF. For Commercial and Light Commercial

VRF. For Commercial and Light Commercial 118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,

More information

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise Product Brochure Fan coil units for suspended ceilings HyPower-Geko Energy efficient Powerful Hygienic Low noise Optimal climate: Hygienic. Efficient. Sustainable. The HyPower-Geko fan coil units generate

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Reversible air-to-water scroll heat pumps

Reversible air-to-water scroll heat pumps Reversible air-to-water scroll heat pumps Model CXAO 120 to 290 Cooling capacity: 420-1030 kw Heating capacity: 475-1175 kw CG-PRC027A-GB Table of Contents Model number description...4 Technical specifications...5

More information

1.1 VTS: Manufacturer No. 1 in the world constituents of success

1.1 VTS: Manufacturer No. 1 in the world constituents of success Air curtain 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 WING 2.1 WING air curtains 2.2 Silence and power 2.3 Design and performance 2.4 Quality and design 2.5

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

(ULT200-UM.x-HFM050) Technical Documentation

(ULT200-UM.x-HFM050) Technical Documentation SRA200.x-01 (ULT200-UM.x-HFM050) Technical Documentation Date of issue: 07 / 2010 clean air, strong performance SRA-series, modular air extraction and filtration units for Air handling equipment for environmental

More information

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England

More information

SPECTRACOOL SLIM FIT AIR CONDITIONERS EQUIPMENT PROTECTION

SPECTRACOOL SLIM FIT AIR CONDITIONERS EQUIPMENT PROTECTION SPECTRACOOL SLIM FIT AIR CONDITIONERS Design with CONFIDENCE EQUIPMENT PROTECTION THE ULTIMATE IN COOLING CONVENIENCE Loaded with features and options to take the hassles out of industrial cooling. Spectracool

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000.

The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000. 16 The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000. The S1500 has been designed to ventilate a room with occupancies from 35 to 100 people, the S1200 for spaces

More information

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm) COMPRESSORS MOBILAIR M 115 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min (265 405 cfm) www.kaeser.com MOBILAIR M 115 The powerful combination of the highly efficient

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

COMPRESSORS MOBILAIR M 36/M 45. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min ( cfm)

COMPRESSORS MOBILAIR M 36/M 45. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min ( cfm) COMPRESSORS MOBILAIR M 36/M 45 Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min (135 150 cfm) www.kaeser.com MOBILAIR M 36/M 45 The perfect energy-saving combination:

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

Product range Solex Technical data and dimensioning. 5 Years

Product range Solex Technical data and dimensioning. 5 Years Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system

More information

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension Air cooled Condensers New condenser generation with better performance Capacities 9-1060 kw Ripple Fin tubing Floating coil block suspension Eurovent certified Capacities based on ENV 327 voor R404A *DX

More information

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm) KOMPRESSOREN MOBILAIR M 43/M 50 Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min (150 180 cfm) www.kaeser.com MOBILAIR M 43/M 50 The perfect energy-saving combination:

More information