ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/

Size: px
Start display at page:

Download "ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/"

Transcription

1 GROUNDING CABLE/MATERIAL Contact: John Messina (203) CABLE/WIRE: Class B - Standard Strand (Type 3 Braid) CABLE/WIRE 14 AWG-Stranded RHH 90C Rated Dry/Damp & 60C Wet, Braid CABLE/WIRE 12 AWG-Stranded Covered - Non-Halogen Insulation,Tinned CABLE/WIRE 10 AWG-Stranded Copper Conductor; TelcoFlex Types 3 & 4 or CABLE/WIRE 8 AWG-Stranded KS L3, L4 Manufactured by American CABLE/WIRE 6 AWG-Stranded Insulated Wire (AIW) or FlexTel Types 3 & 4 CABLE/WIRE 4 AWG-Stranded Distributed by Cablcon. CABLE/WIRE 2 AWG-Stranded CABLE/WIRE 0 AWG-Stranded CABLE/WIRE 00 AWG-Stranded No Equivalents or Substitutions from the CABLE/WIRE 0000 AWG-Stranded Cable and Manufacturers Listed Above are CABLE/WIRE 350 KCMIL-Stranded Acceptable CABLE/WIRE 500 KCMIL-Stranded CABLE/WIRE 750 KCMIL-Stranded Class I - Flexible Strand (Type 4 Braid) CABLE/WIRE 8 AWG-Flex CABLE/WIRE 6 AWG-Flex CABLE/WIRE 4 AWG-Flex CABLE/WIRE 2 AWG-Flex (See ATT-E E Note 17 Regarding CABLE/WIRE 0 AWG-Flex the Color of Grounding Cable in the CABLE/WIRE 00 AWG-Flex Various AT&T Regions.) CABLE/WIRE 0000 AWG-Flex CABLE/WIRE 350 KCMIL-Flex CABLE/WIRE 500 KCMIL-Flex CABLE/WIRE 750 KCMIL-Flex : #14-10 AWG 1-Hole 1/4" Bolt Compression connectors required; unless limited #14-10 AWG 1-Hole 1/4" 45DEG access requires the use of mechanical connectors #14-10 AWG 2-Hole 1/4" Bolt or the device is designed for mechanical lugs only #14-10 AWG 2-Hole 3/8" Bolt (See Section K, TP 76300). #14-10 AWG 2-Hole #10 Stud Hole Tin plated copper crimp lugs with UL rating; Inspection window required on all terminal lugs #6 AWG 1-Hole 1/4" Bolt (except battery posts) - (See Sec 12-TP 76400); #6 AWG 1-Hole 1/4" 45DEG Burndy, Panduit, or T&B. #6 AWG 1-Hole Narrow Tongue #6 Stud (Belled end compression lugs shall not be used #6 AWG 2-Hole 1/4" Bolt for any CO application.) #6 AWG 2-Hole 3/8" Bolt Page 1

2 : Continued #4 AWG 1-Hole 1/4" Bolt #4 AWG 1-Hole 1/4" 45DEG #4 AWG 1-Hole Narrow Tongue #10, 1/4" (.40" Panduit Narrow Tongue Width*) #4 AWG 2-Hole 1/4" Bolt #4 AWG 2-Hole 3/8" Bolt #2 AWG 1-Hole 1/4" Bolt #2 AWG 1-Hole 1/4" 45DEG #2 AWG 2-Hole 1/4" Bolt #2 AWG 1-Hole Narrow Tongue #10, 1/4" (.42" Panduit Narrow Tongue Width*) #2 AWG 2-Hole Narrow Tongue 1/4" Bolt (.42" Panduit;.48" Burndy - Narrow Tongue Width*) #2 AWG 2-Hole 3/8" Bolt * Note: NT Connectors only accept Class "B" cable 1/0 AWG 2-Hole 1/4" Bolt 1/0 AWG 2-Hole 3/8" Bolt 2/0 AWG 2-Hole 1/4" Bolt 2/0 AWG 2-Hole 3/8" Bolt 4/0 AWG 2-Hole 1/4" Bolt 4/0 AWG 2-Hole 3/8" Bolt 4/0 FLEX 2-Hole 3/8" Bolt Burndy YAV28L2TC_FX OK; Do not use YAV29L2TC_FX 350KCM 2-Hole 1/4" Bolt 350KCM 2-Hole 3/8" Bolt 350KCM FLEX 2-Hole 3/8" 500KCM 2-Hole 3/8" Bolt 500KCM FLEX 2-Hole 3/8" 750KCM 2-Hole 3/8" Bolt 750KCM 2-Hole NT 3/8" Bolt 750KCM FLEX 2-Hole 3/8" H-TAP : 2-6 main 2-14 H-Tap w/ COV H-Taps must be a compression connector type; 00-2 main 00-2 H-Tap w/ COV H-Taps require a UL clear cover with an oxygen main 8-14 H-Tap w/ COV index of 28% & UL 94-V1 or better rating; must also main 2-14 H-Tap w/ COV meet fire resistance requirements of TP /0 main H-Tap w/cov Burndy, or T&B. (Panduit H-Taps require a special main 500-4/0 H-Tap w/cov die set, and shall not be used.) main 4/0-14 H-Tap w/cov Note: In-Line Reducer Connectors shall main H-Tap w/cov be used in place of H-Tap Connectors where feasible Page 2

3 H-TAP COVERS FCI-Burndy: All Sizes Available in Clear CLEAR H-TAP COVERS: CCFBG-FR Max #6 Flex/Strand Conductor FCI Burndy and T&B have developed clear H-TAP CCFO-FR Max #2 Flex/Strand Conductor covers that are required for use rather than CCFD-FR Max 4/0 Strand Conductor "Black" H-TAP covers. CCFDX-FR Max 4/0 Flex Conductor CCFN-FR Max 500 Strand or 350 Flex CCFR-FR Max 750 Flex/Stand Conductor The clear covers of either manufacturer are [See ATT-P E for H-TAP Conn. To compatible for use with either FCI-Burndy or T&B Clear H-TAP Cover Size Table] H-TAPS. FCI-Burndy can provide clear covers for all sizes of H-TAPS; T&B currently has one size T&B: 1 Clear Cover Size HTCV2CLRFR for use with H-TAP sizes: 2-6 main 2-14 Branch main Branch main 8-14 Branch main 2-14 Branch C-TAP : No. 6 - No. 6 C Tap C-Taps must be a compression connector type; No. 2 - No. 6 C Tap C-Taps must be type: YC-L thin-wall copper; No. 6 - No. 1/0 C Tap C-Taps must be UL listed to 600 volts HEAT SHRINK (HS) - THIN WALL HEAT SHRINK AWG CLEAR UL 224, VW-1 Rated, Flame Retardant Properties; HEAT SHRINK 12-8 AWG CLEAR Clear or Black Thin Wall HS Available from HEAT SHRINK 6-4 AWG CLEAR Burndy & T&B HEAT SHRINK 1/2" BLACK TUBING HEAT SHRINK 3/8" BLACK TUBING HEAT SHRINK 3/4" BLACK TUBING HEAT SHRINK 1" BLACK TUBING HEAT SHRINK 2" BLACK TUBING HEAT SHRINK SLV VARNISHED #20 (HT20BSW000) Available from Lineage (ComClass B by the Foot from Lineage Cust. Service (800) or a Lineage VAR) HEAT SHRINKABLE END CAP - HEAVY WALL HEAT SHRINK 8-1 AWG END CAP UL 94-VO Rated, Self-extinguish. Flame Retardant HEAT SHRINK 4-4/0 END CAP Properties; Must Meet ANSI-C119.1, UL486D HEAT SHRINK 1/0-500KCM END CAP Sealing Requirements, HS End Caps Available HEAT SHRINK 3/ KCM E-CAP From Burndy & T&B HEAT SHRINK KCM END CAP Page 3

4 MISCELLANEOUS: Miscellaneous #10 to #26 Ring Type Connectors Burndy VINYLUG, T&B STA-KON (TP 76400), Lucent WP91412, or Panduit Nylon Insulated Miscellaneous "Do Not Disconnect Lead" Tag Available from Lucent ( ) Miscellaneous 145P-Tag ( ) Lexan Non-Flammable Tag Available from Burndy May be Used in Conjunction with Non-Flammable Adhesive Tags or Stamped/Stenciled; (Fiber Type Numbering Tags shall not be used) Miscellaneous Brady P-Tag Label Fire retardant label available from Brady; if used to identify power and grounding cables, the Brady label must be applied to the 145P-Tag ( ) to maintain durability Miscellaneous Gray-Fiber.015" x 40" x 48" Sheeting Available from Lucent ( ) Miscellaneous Plastic Poly Vynl Tubing Available from Lucent ( ) Miscellaneous 9/10/12 Ply Cord * Note: The list above covers the bulk of the minor material used for the installation of Grounding and Bonding of Telecommunications Equipment, Power Systems, and Central Offices However, it is not possible to list the required components for every job variable. The Installation Supplier should follow the intent of this list to provide quality components that meet AT&T Installation and Engineering Requirements. (See TP Installation Requirements, and TP Engineering Requirements.) Page 4

5 Contact: Jim Jackson (916) DC POWER DISTRIBUTION or Bill Price (817) CABLE/WIRE: Class B - Standard Strand (Type 3 Braid) CABLE/WIRE 14 AWG-Stranded RHH 90C Rated Dry/Damp & 60C Wet, Braid CABLE/WIRE 12 AWG-Stranded Covered - Non-Halogen Insulation,Tinned CABLE/WIRE 10 AWG-Stranded Copper Conductor; TelcoFlex Types 3 & 4 or CABLE/WIRE 8 AWG-Stranded KS L3, L4 Manufactured by American CABLE/WIRE 6 AWG-Stranded Insulated Wire (AIW) or FlexTel Types 3 & 4 CABLE/WIRE 4 AWG-Stranded Distributed by Cablcon. CABLE/WIRE 2 AWG-Stranded CABLE/WIRE 0 AWG-Stranded CABLE/WIRE 00 AWG-Stranded CABLE/WIRE 0000 AWG-Stranded CABLE/WIRE 350 KCMIL-Stranded CABLE/WIRE 500 KCMIL-Stranded CABLE/WIRE 750 KCMIL-Stranded Class I - Flexible Strand (Type 4 Braid) CABLE/WIRE 8 AWG-Flex CABLE/WIRE 6 AWG-Flex AIW TelcoFlex Type 2 or KS L-2 CABLE/WIRE 4 AWG-Flex Black Non-Braid Covered Insulation CABLE/WIRE 2 AWG-Flex (Non-Halogen - RHH Rated) Power CABLE/WIRE 0 AWG-Flex Cable may be use as an alternative to CABLE/WIRE 00 AWG-Flex KS L-4 Gray Braid Covered Cable for CABLE/WIRE 0000 AWG-Flex Battery and Rectifier Connections Only; CABLE/WIRE 350 KCMIL-Flex (See TP 76300MP - Section J - for Cable CABLE/WIRE 500 KCMIL-Flex Protection Requirements When Securing) CABLE/WIRE 750 KCMIL-Flex No Equivalents or Substitutions from the Cable and Manufacturers Listed Above are Acceptable. Page 5

6 CABLE/WIRE: Continued SMALL AWG (INTRA-BAY) POWER WIRE: Exane TXE Multi-Strand POWER WIRE 16 AWG-Stranded (14 AMPs*) Exane -1068A 600 Volt, AAR S-501/RP-585, POWER WIRE 18 AWG-Stranded (12 AMPs*) (XLPO), Spec. DAA1068A Thermoset - POWER WIRE 20 AWG-Stranded (10 AMPs*) Non-Halogen Insulation,Tinned Multi-Strand Copper Conductor Manufactured by (* AT&T Specified Maximum Amperage) ROCKBESTOS SURPRENANT CABLE; Distributed by ElectroWire Shall be used for AWG battery and return intra-bay wiring from the Transport Bay Fuse Panel to the Network Element within the Transport Bay where AIW TelcoFlex 14AWG and larger size power cable is not needed for small amperage loads. (Transition to this new power wire is required by 5/1/10; no substitutions allowed after 5/1.) Available in gray insulation with red, black, or green tracer available on request. CIRCUIT BREAKERS DC CIRCUIT BREAKER AMP CIRCUIT BREAKERS: DC/UL Rated; Thermal-Magnetic or Magnetic, Trip Free Type; See Sec 6-TP 76400; Available from AIRPAX or Heinman : Compression connectors required; unless limited #14-10 AWG 1-Hole #10 Bolt access requires the use of mechanical connectors #14-10 AWG 1-hole #10 bolt 45º & 90º or the device is designed for mechanical lugs only #14-10 AWG 1-Hole 1/4" Bolt (See Section K, TP 76300). #14-10 AWG 1-Hole 1/4" 45 & 90º Tin plated copper crimp lugs with UL rating; #14-10 AWG 2-Hole #10 Inspection window required on all terminal lugs #14-10 AWG 2-Hole #10 bolt 45º & 90º (except battery posts) - (See Sec 12-TP 76400); #14-10 AWG 2-Hole 1/4" Bolt Burndy, Panduit, or T&B AWG 2-Hole 1/4" bolt 45º & 90º (Belled end compression lugs shall not be used #14-10 AWG 2-Hole 3/8" Bolt for any CO application.) #14-10 AWG 2-hole 3/8" 45º & 90º Page 6

7 : (Continued) #8 AWG 1-Hole #10 Bolt #8 AWG 1-Hole #10 Bolt #8 AWG 1-Hole 1/4" Bolt #8 AWG 1-Hole 1/4" 45DEG #8 AWG 1-Hole Narrow Tongue #6 Stud (.27" Panduit;.29" Burndy - Narrow Tongue Width*) #8 AWG 1-Hole 5/16" Bolt #8 AWG 1-Hole 5/16" Bolt 45º & 90º #8 AWG 1-Hole 3/8" Bolt #8 AWG 1-Hole 3/8" Bolt 45º & 90º #8 AWG 2-Hole #10 Bolt #8 AWG 2-Hole #10 Bolt 45º & 90º #8 AWG 2-Hole 1/4" Bolt #8 AWG 2-Hole 1/4" Bolt 45º & 90º #8 AWG 2-Hole 5/16" Bolt #8 AWG 2-Hole 5/16" Bolt 45º & 90º #8 AWG 2-Hole 3/8" Bolt #8 AWG 2-Hole 3/8" Bolt 45º & 90º #6 AWG 1-Hole #10 Bolt #6 AWG 1-Hole #10 Bolt 45º & 90º #6 AWG 1-Hole 1/4" Bolt #6 AWG 1-Hole 1/4" Bolt 45º & 90º #6 AWG 1-Hole 5/16" Bolt #6 AWG 1-Hole 5/16" Bolt 45º & 90º #6 AWG 1-Hole 3/8" Bolt #6 AWG 1-Hole 3/8" Bolt 45º & 90º #6 AWG 1-Hole Narrow Tongue #6 Stud (.31" Panduit;.29" Burndy -T&B Narrow Tongue Width*) #6 AWG 2-Hole #10 Bolt #6 AWG 2-Hole #10 Bolt 45 & 90 DEG #6 AWG 2-Hole 1/4" Bolt #6 AWG 2-Hole 1/4" Bolt 45º & 90º #6 AWG 2-Hole 5/16" Bolt #6 AWG 2-Hole 5/16" Bolt 45º & 90º #6 AWG 2-Hole 3/8" Bolt #6 AWG 2-Hole 3/8" Bolt 45º & 90º #4 AWG 1-Hole #10 Bolt #4 AWG 1-Hole #10 Bolt 45º & 90º #4 AWG 1-Hole 1/4" Bolt Page 7

8 : (Continued) #4 AWG 1-Hole 1/4" 45º & 90º #4 AWG 1-Hole Narrow Tongue #10, 1/4" (.40" Panduit Narrow Tongue Width*) #4 AWG 1-Hole 5/16" Bolt #4 AWG 1-Hole 5/16" 45º & 90º #4 AWG 1-Hole 3/8" Bolt #4 AWG 1-Hole 3/8" Bolt 45º & 90º #4 AWG 2-Hole 1/4" Bolt #4 AWG 2-Hole 1/4" 45º & 90º #4 AWG 2-Hole 3/8" Bolt #4 AWG 2-Hole 3/8" Bolt 45º & 90º #4 AWG 2-Hole 5/16" Bolt #4 AWG 2-Hole 5/16" Bolt 45º & 90º #4 AWG 2-Hole 1/2" Bolt #4 AWG 2-Hole 1/2" Bolt 45º & 90º #2 AWG 1-Hole Narrow Tongue #10, 1/4" (.42" Panduit Narrow Tongue Width*) #2 AWG 1-Hole 1/4" Bolt #2 AWG 1-Hole 1/4" 45º & 90º #2 AWG 1-Hole 3/8" Bolt #2 AWG 1-Hole 3/8" 45º & 90º #2 AWG 1-Hole 1/2" Bolt #2 AWG 1-Hole 1/2" 45º & 90º #2 AWG 2-Hole 1/4" Bolt #2 AWG 2-Hole 1/4" Bolt 45º & 90º #2 AWG 2-Hole Narrow Tongue 1/4" Bolt (.42" Panduit;.48" Burndy - Narrow Tongue Width*) #2 AWG 2-Hole 5/16" Bolt #2 AWG 2-Hole 5/16" Bolt 45º & 90º #2 AWG 2-Hole 3/8" Bolt #2 AWG 2-Hole 3/8" Bolt 45º & 90º #2 AWG 2-Hole 1/2" Bolt #2 AWG 2-Hole 1/2" Bolt 45º & 90º 1/0 AWG 1-Hole 5/16" Bolt 1/0 AWG 1-Hole 5/16" Bolt 45 & 90 DEG 1/0 AWG 2-Hole 1/4" Bolt 1/0 AWG 2-Hole 1/4" Bolt 45º & 90º 1/0 AWG 2-Hole 5/16" Bolt 1/0 AWG 2-Hole 5/16" Bolt 45º & 90º 1/0 AWG 2-Hole 3/8" Bolt 1/0 AWG 2-Hole 3/8" Bolt 45º & 90º 1/0 AWG 2-Hole 1/2" Bolt 1/0 AWG 2-Hole 1/2" Bolt 45º & 90º * Note: NT Connectors only accept Class "B" cable Page 8

9 : (Continued) 2/0 AWG 1-Hole 5/16" Bolt 2/0 AWG 1-Hole 5/16" Bolt 45 & 90 DEG 2/0 AWG 2-Hole 1/4" Bolt 2/0 AWG 2-Hole 1/4" Bolt 45º & 90º 2/0 AWG 2-Hole 5/16" Bolt 2/0 AWG 2-Hole 5/16" Bolt 45º & 90º 2/0 AWG 2-Hole 3/8" Bolt 2/0 AWG 2-Hole 3/8" Bolt 45º & 90º 2/0 AWG 2-Hole 1/2" Bolt 2/0 AWG 2-Hole 1/2" Bolt 45 & 90 DEG 4/0 FLEX 1-Hole 1/2" Bolt Burndy YAV28LTC_FX OK; Do not use YAV29LTC_FX 4/0 AWG 2-Hole 1/4" Bolt 4/0 AWG 2-Hole 3/8" Bolt 4/0 FLEX 2-Hole 3/8" Bolt Burndy YAV28L2TC_FX OK; Do not use YAV29L2TC_FX 4/0 AWG 2-Hole 1/2" Bolt 4/0 FLEX 2-Hole 1/2" Bolt Burndy YAV28L2TC_FX OK; Do not use YAV29L2TC_FX 350KCM 2-Hole 1/4" Bolt 350KCM 2-Hole 5/16" Bolt 350KCM 2-Hole 3/8" Bolt 350KCM FLEX 2-Hole 3/8" 350KCM 2-Hole 1/2" Bolt 500KCM 2-Hole 3/8" Bolt 500KCM FLEX 2-Hole 3/8" 500KCM 2-Hole 1/2" Bolt 750KCM 2-Hole 3/8" Bolt 750KCM 2-Hole NT 3/8" Bolt 750KCM FLEX 2-Hole 3/8" 750KCM 2-Hole 1/2" Bolt BATTERY : CONN. BATTERY 4/0 FLEX 1-Hole 5/16" Bolt Lead plated copper lugs without inspection holes CONN. BATTERY 4/0 FLEX 2-Hole 5/16" Bolt used for battery terminal/terminal plate connec- CONN. BATTERY 4/0 FLEX 2-Hole 1/2" Bolt tions only, stainless steel hardware required at CONN. BATTERY 350KCM FLEX 1-Hole 5/16" Bolt battery; the tongue face must be large enough CONN. BATTERY 350KCM FLEX 2-Hole 5/16" Bolt for the washer to rest completely on the tongue CONN. BATTERY 350KCM FLEX 2-Hole 1/2" Bolt face; 2 hole battery posts require 2 hole lugs; (Belled end compression lugs shall not be used for battery connections.) Burndy, Panduit, and T&B each manufactures several sizes, but not necessarily all of the listed battery connectors. However, all connectors are available. Check with local distributors or the manufacturer for the required sizes. Page 9

10 H-TAP : 2-6 main 2-14 H-Tap w/ COV H-Taps must be a compression connector type; main 8-14 H-Tap w/ COV H-Taps require a UL clear cover with an oxygen main 2-14 H-Tap w/ COV index of 28% & UL 94-V1 or better rating; must also 500-4/0 main H-Tap w/cov meet fire resistance requirements of TP main 500-4/0 H-Tap w/cov Burndy, or T&B. (Panduit H-Taps require a special main 4/0-14 H-Tap w/cov die set, and shall not be used.) main H-Tap w/cov Note: In-Line Reducer Connectors shall be used in place of H-Tap Connectors where feasible H-TAP COVERS FCI-Burndy: All Sizes Available in Clear CLEAR H-TAP COVERS: CCFBG-FR Max #6 Flex/Strand Conductor FCI Burndy and T&B have developed clear H-TAP CCFO-FR Max #2 Flex/Strand Conductor covers that are required for use rather than CCFD-FR Max 4/0 Strand Conductor "Black" H-TAP covers. CCFDX-FR Max 4/0 Flex Conductor CCFN-FR Max 500 Strand or 350 Flex CCFR-FR Max 750 Flex/Stand Conductor The clear covers of either manufacturer are [See ATT-P E for H-TAP Conn. To compatible for use with either FCI-Burndy or T&B Clear H-TAP Cover Size Table] H-TAPS. FCI-Burndy can provide clear covers for all sizes of H-TAPS; T&B currently has one size T&B: 1 Clear Cover Size HTCV2CLRFR for use with H-TAP sizes: main Branch main 8-14 Branch main 2-14 Branch IN-LINE REDUCING : Burndy, Panduit, and Thomas & Betts In-Line Reducing Connectors are approved for use, and are listed separately by manufacturer due to different size ranges. Note: Both short and long barrel In-line Reducer Connectors can be used; however, the short barrel connectors exceed UL pullout requirements; therefore, the use and extra expense of long barrel connectors are not necessary unless the short barrels are not available from supply sources Page 10

11 IN-LINE REDUCING : Cont. FCI-Burndy YSR-TC Series #10 Flex/Class B to #14 Flex/Class B Splice kit includes connector, and one or more #10 Flex/Class B to #12 Flex/Class B pieces of clear heat shrink tubing; UL 224, VW-1 #8 Flex/Class B to #14 Flex/Class B Rated, Flame Retardant Properties - Note: #8 Flex/Class B to #10 Flex/Class B Only kits with clear heat shrink are acceptable; #6 Flex/Class B to #10 Flex/Class B follow manufacturer installation instructions for #6 Flex/Class B to #8 Flex/Class B application #4 Flex/Class B to #10, 12, 14 Class B It is a requirement for In-Line Reducer Connectors #4 Flex/Class B to #8 Flex/Class B to be used in place of H-Taps where feasible to #4 Flex/Class B to #6 Flex/Class B reduce cable pile-up & improve connectivity. #2 Flex/Class B to #4 Flex/Class B #2 Flex/Class B to #6 Flex/Class B #2 Flex/Class B to #8 Flex/Class B 1/0 Flex/Class B to #2 Flex/Class B 1/0 Flex/Class B to #4 Flex/Class B 1/0 Flex/Class B to #6 Flex/Class B 2/0 Flex/Class B to 1/0 Flex/Class B 2/0 Flex/Class B to #2 Flex/Class B 2/0 Flex/Class B to #4 Flex/Class B 2/0 Flex/Class B to #6 Flex/Class B 4/0 Class B to 1/0 Flex/Class B 4/0 Class B to #2 Flex/Class B 4/0 Class B to #4 Flex/Class B 4/0 Class B to #6 Flex/Class B 4/0 Flex to 4/0 Class B 4/0 Flex to 2/0 Flex/Class B 4/0 Flex to 1/0 Flex/Class B 4/0 Flex to #2 Flex/Class B 4/0 Flex to #4 Flex/Class B 350 Class B to 1/0 Flex/Class B 350 Class B to 2/0 Flex/Class B 350 Class B to 4/0 Class B 350 Class B to 4/0 Flex 350 Class B to #2 Flex/Class B 350 Class B to #4 Flex.Class B 350 Class B to #6 Flex/Class B 350 Flex to 1/0 Flex/Class B 350 Flex to 2/0 Flex/Class B 350 Flex to 4/0 Flex Page 11

12 IN-LINE REDUCING : Cont. FCI-Burndy YSR-TC Series (Continued) 350 Flex to 4/0 Class B 350 Flex to 350 Class B 350 Flex to #2 Flex/Class B 350 Flex to #4 Flex/Class B 350 Flex to #6 Flex/Class B 500 Class B to 1/0 Flex/Class B 500 Class B to 2/0 Flex/Class B 500 Class B to 4/0 Class B 500 Class B to 4/0 Flex 500 Class B to 350 Class B 500 Class B to 350 Flex 500 Flex to 2/0 Flex/Class B 500 Flex to 4/0 Class B 500 Flex to 4/0 Flex 500 Flex to 350 Class B 500 Flex to 500 Class B 500 Flex to 350 Flex 750 Class B to 4/0 Class B 750 Class B to 4/0 Flex 750 Class B to 350 Class B 750 Class B to 350 Flex 750 Class B to 500 Class B 750 Class B to 500 Flex 750 Flex to 4/0 Class B 750 Flex to 4/0 Flex 750 Flex to 350 Class B 750 Flex to 350 Flex 750 Flex to 500 Class B 750 Flex to 500 Flex 750 Flex to 750 Class B 750 Class B to 750 Class B (In-line Splice - Barrel Tap) Page 12

13 IN-LINE REDUCING : Cont. Panduit RSCK Series #4 Class B to #6 Class B Splice kit includes connector, and one or more #2 Class B to #6 Class B pieces of clear heat shrink tubing; UL 224, V-1 #2 Class B to #4 Class B Rated, Flame Retardant Properties - Note: 1/0 Class B to #6 Class B Only kits with clear heat shrink are acceptable; 1/0 Class B to #4 Class B follow manufacturer installation instructions for 2/0 Class B to #6 Class B application 2/0 Class B to #4 Class B 4/0 Class B to #6 Class B 4/0 Class B to #4 Class B 4/0 Class B to 1/0 Class B 4/0 Class B to 2/0 Class B 500 Class B to 4/0 Flex 500 Class B to 350 Flex It is a requirement for In-Line Reducer Connectors 750 Class B to 4/0 Class B to be used in place of H-Taps where feasible to 750 Class B to 4/0 Flex reduce cable pile-up & improve connectivity. 750 Class B to 350 Flex 750 Class B to 500 Class B 750 Class B to 500 Flex 750 Class B to 750 Class B 750 Flex to 4/0 Class B 750 Flex to 750 Class B #2 Class B to #6 Class B & Flex Thomas & Betts (T&B) TBRS Series 1/0 Class B to #6 Class B & Flex 1/0 Class B to #2 Class B 1/0 Flex/Class B to #6 Class B Splice kit includes connector, 1 larger and 1 1/0 Flex/2/0 Class B to #2 Class B smaller clear heat shrink tubing; UL 224, V-1 1/0 Flex/2/0 Class B to #6 Class B & Flex Rated, Flame Retardant Properties - Note: 1/0 Flex/2/0Class B to #2 Class B Only kits with clear heat shrink are acceptable; 4/0 Class B to #6 Class B & Flex follow manufacturer installation instructions for 4/0 Class B to #2 Class B application 500 Flex/750 Class B to 4/0 Class B 500 Flex/750 Class B to 4/0 Flex It is a requirement for In-Line Reducer Connectors 500 Flex/750 Class B to 350 Flex, 500 Class B to be used in place of H-Taps where feasible to 500 Flex/750 Class B to 500 Flex, 750 Class B reduce cable pile-up & improve connectivity. 750 Flex to 4/0 Flex 750 Flex to 350 Flex, 500 Class B 750 Flex to 500 Flex, 750 Class B Page 13

14 DESIGNATION RIVET Color Designation Rivets- 1/4A Violet GMT Type Fuse Identifier, Available from Telect DESIGNATION RIVET Color Designation Rivets- 1/2A Red DESIGNATION RIVET Color Designation Rivets- 3/4A Brown DESIGNATION RIVET Color Designation Rivets- 1A Gray DESIGNATION RIVET Color Designation Rivets- 1-1/3A White DESIGNATION RIVET Color Designation Rivets- 2A Orange DESIGNATION RIVET Color Designation Rivets- 3A Blue DESIGNATION RIVET Color Designation Rivets- 5A Green DESIGNATION RIVET Color Designat Rivets- 7-1/2A Black/White DESIGNATION RIVET Color Designation Rivets- 10A Red/White DESIGNATION RIVET Color Designation Rivets- 15A Red/Blue DESIGNATION PIN Color Designation Pins- 1/4A Violet 70 Type Fuse Identifier, Available from Bussmann DESIGNATION PIN Color Designation Pins- 1/2A Red DESIGNATION PIN Color Designation Pins- 3/4A Brown DESIGNATION PIN Color Designation Pins- 1-1/3A White DESIGNATION PIN Color Designation Pins- 2A Orange DESIGNATION PIN Color Designation Pins- 3A Blue DESIGNATION PIN Color Designation Pins- 5A Green/Black DESIGNATION PIN Color Designation Pins- 8A Brown/White DESIGNATION PIN Color Designation Pins- 10A Violet/Yellow : FUSE 35F 1/2 AMP - Red GMT style and Telpower-type fuses shall be used FUSE 35A 1 1/3 AMP - White on DC circuits unless another type of fuse is FUSE 35G 3 AMP - Blue specified in the applicable AT&T Equipment or FUSE 35H 5 AMP - Green Power Drawing; TP Sec. M; Bussmann Telpower Fuses shall be used unless another manufacturer is specified on the MML for a specific fuse type or size FUSE 70A 1-1/3 AMP- White Manufactured by Bussmann FUSE 70B 2 AMP - Orange FUSE 70C 3 AMP - Blue FUSE 70D 5 AMP - Green/Black FUSE 70F 1/4 AMP - Violet FUSE 70G 1/2 AMP - Red FUSE 70H 3/4 AMP - Brown FUSE 70M 8 AMP - Brown/White FUSE 70N 10 AMP - Violet/Yellow FUSE DUMMY 72B - 70 Type Page 14

15 : Continued FUSE 74A 1-1/4 AMP Manufactured by Bussmann FUSE 74B 3 AMP FUSE 74C 5 AMP FUSE 74D 10 AMP FUSE 74F 20 AMP FUSE 74J 7-1/2 AMP FUSE GMT 18/100 AMP - Yellow (GMT-A) Manufactured by Bussmann FUSE GMT 1/4 AMP - Violet FUSE GMT 1/2 AMP - Red FUSE GMT 3/4 AMP - Brown FUSE GMT 1 AMP - Gray FUSE GMT 1 1/3 AMP - White FUSE GMT 2 AMP - Orange FUSE GMT 3 AMP - Blue FUSE GMT 5 AMP - Green FUSE GMT 7 1/2 AMP - Black/White FUSE GMT 10 AMP - Red/White FUSE GMT 15 AMP - Red/Blue FUSE DUMMY GMT - GMT Type FUSE Type 18/100 AMP - Yellow GMT Equivalent Manufactured by Littelfuse FUSE Type 1/4 AMP - Violet FUSE Type 1/2 AMP - Red FUSE Type 3/4 AMP - Brown FUSE Type 1 AMP - Gray FUSE Type 1 1/3 AMP - White FUSE Type 2 AMP - Orange FUSE Type 3 AMP - Blue FUSE Type 5 AMP - Green FUSE Type 7 1/2 AMP - Black/White FUSE Type 10 AMP - Red/White FUSE Type 15 AMP - Red/Blue FUSE Type 20 AMP - Green/White Telect/Hendry 20A Holder Required FUSE KLM 10 AMP KLM Fuses 13/32"X1/1/2" NON-TP; Only UL Rated; FUSE KLM 15 AMP Available from Bussmann (KTK Fuse Replacement FUSE KLM 20 AMP for Telect 0HCKTK High Current Fuse Panel) FUSE KLM 25 AMP Page 15

16 : Continued FUSE TPA 3 AMP Manufactured by Bussmann FUSE TPA 5 AMP FUSE TPA 10 AMP FUSE TPA 15 AMP FUSE TPA 20 AMP FUSE TPA 25 AMP FUSE TPA 30 AMP FUSE TPA 40 AMP FUSE TPA 50 AMP FUSE TPN 5 AMP Manufactured by Bussmann FUSE TPN 10 AMP FUSE TPN 15 AMP FUSE TPN 20 AMP FUSE TPN 25 AMP FUSE TPN 30 AMP FUSE TPN 35 AMP FUSE TPN 40 AMP FUSE TPN 45 AMP FUSE TPN 50 AMP FUSE TPN 60 AMP FUSE TPS 3 AMP Manufactured by Bussmann FUSE TPS 5 AMP FUSE TPS 10 AMP FUSE TPS 15 AMP FUSE TPS 20 AMP FUSE TPS 25 AMP FUSE TPS 30 AMP FUSE TPS 40 AMP FUSE TPS 50 AMP FUSE TPS 60 AMP FUSE TPS 70 AMP Page 16

17 : Continued FUSE TLS 3 AMP TLS fuses available from Littelfuse, Emerson, & FUSE TLS 5 AMP misc. suppliers; TFD-101 Disconnect/Fuse Holder FUSE TLS 10 AMP required to use TLS A fuses FUSE TLS 15 AMP FUSE TLS 20 AMP FUSE TLS 25 AMP FUSE TLS 30 AMP FUSE TLS 40 AMP FUSE TLS 50 AMP FUSE TLS 60 AMP FUSE TLS 70 AMP FUSE TLS 80 AMP FUSE TLS 90 AMP FUSE TLS 100 AMP FUSE TLS 125 AMP TFD Disconnect/Fuse Holder TFD-101 Canadian Disconnect/Fuse Shunt, Emerson, Holder Telect, available RPG & misc. from suppliers; Order TFD with Internal Alarm Schem. "C" configuration (TFD ); shall be used with TPS 5-70A and TLS 5-125A fuses; additional info. FUSE TPL-BA 70 AMP Manufactured by Bussmann FUSE TPL-BB 80 AMP FUSE TPL-BD 100 AMP FUSE TPL-BE 125 AMP FUSE TPL-BF 150 AMP FUSE TPL-BH 200 AMP FUSE TPL-BK 225 AMP FUSE TPL-BL 250AMP FUSE TPL-CN 300 AMP FUSE TPL-CR 400 AMP FUSE TPL-CV 500 AMP FUSE TPL-CZ 600 AMP FUSE REDUCERS: Require AT&T LEC Eng. Authorization, See Sec M- FUSE REDUCERS TP 76300; Available from Bussmann Page 17

18 HARDWARE: BOLTS, NUTS, WASHERS HARDWARE BOLT - 1/4-20 X 3/4 Durium or Equiv. Silicon-Bronze Per ASTM B99, HARDWARE BOLT - 1/4-20 X 1 for Distribution Circuits; Available from Burndy & HARDWARE BOLT - 1/4-20 X 1-1/4 T&B; also Trivalent Chromium plated SAE J429 Grade 5 bolts (TP Sec 12) HARDWARE BOLT - 3/8-16 X 3/4 HARDWARE BOLT - 3/8-16 X 1 HARDWARE BOLT - 3/8-16 X 1-1/4 HARDWARE BOLT - 5/16-18 X 1-3/4 316 SS 316 Stainless Steel bolts for battery terminal plate HARDWARE BOLT - 5/16-18 X SS or lug conn; available from Battery Manufacturer HARDWARE BOLT - 1/2-13 X 1-3/4 316 SS HARDWARE BOLT - 1/2-13 X SS HARDWARE NUT - 1/4-20 Durium or Equiv. Silicon-Bronze Per ASTM B99, HARDWARE NUT - 3/8-16 for Distribution Circuits; Available from Burndy & T&B; also Trivalent Chromium plated SAE J429 Grade 5 nuts HARDWARE NUT - 5/ SS 316 Stainless Steel nuts for battery terminal plate HARDWARE NUT - 1/ SS or lug conn; available from Battery Manufacturer HARDWARE WASHER - SPLIT 1/4 Durium or Equiv. Silicon-Bronze Per ASTM B99, HARDWARE WASHER - SPLIT 3/8 for Distribution Circuits; Available from Burndy & HARDWARE WASHER - FLAT 1/4 HARDWARE WASHER - FLAT 3/8 T&B; also Trivalent Chromium plated SAE J429 Grade 5 washers HARDWARE WASHER - SPLIT 5/ SS 316 Stainless Steel split washers for battery conn; HARDWARE WASHER - SPLIT 1/2 316 SS available from the Battery Manufacturer HARDWARE WASHER - FLAT 5/ SS 316 Stainless Steel flat washers for battery conn; HARDWARE WASHER - FLAT 1/2 316 SS available from Battery Manufacturer Page 18

19 HEAT SHRINK (HS) - THIN WALL HEAT SHRINK AWG CLEAR UL 224, VW-1 Rated, Flame Retardant Properties; HEAT SHRINK 12-8 AWG CLEAR Clear or Black Thin Wall HS Available from HEAT SHRINK 6-4 AWG CLEAR Burndy & T&B HEAT SHRINK HEAT SHRINK HEAT SHRINK HEAT SHRINK HEAT SHRINK 1/2" BLACK TUBING 3/8" BLACK TUBING 3/4" BLACK TUBING 1" BLACK TUBING 2" BLACK TUBING HEAT SHRINK SLV VARNISHED #20 (HT20BSW000) Available from Lineage (ComClass B by the Foot from Lineage Cust. Service (800) , or a Lineage VAR) HEAT SHRINKABLE END CAP - HEAVY WALL HEAT SHRINK 8-1 AWG END CAP UL 94-VO Rated, Self-extinguish. Flame Retardant HEAT SHRINK 4-4/0 END CAP Properties; Must Meet ANSI-C119.1, UL486D HEAT SHRINK 1/0-500KCM END CAP Sealing Requirements, HS End Caps Available HEAT SHRINK 3/ KCM E-CAP From Burndy & T&B HEAT SHRINK KCM END CAP Page 19

20 MISCELLANEOUS: Burndy VINYLUG, T&B STA-KON (TP 76400), Miscellaneous #10 to #26 Ring Type Connectors Lucent WP91412, or Panduit Nylon Insulated Miscellaneous "Do Not Disconnect Lead" Tag Available from Lucent ( ) Miscellaneous 145P-Tag ( ) Lexan Non-Flammable Tag Available from Burndy May be Used in Conjunction with Non-Flammable Adhesive Tags or Stamped/Stenciled; (Fiber Type Numbering Tags shall not be used) Miscellaneous Brady Double Sided P-Tag Label Fire retardant label available from Brady; if used to identify power and grounding cables, the Brady label must be applied to the 145P-Tag ( ) to maintain durability Miscellaneous Fuse Post Stiffener Required for #1/0 Power Cable Connections Miscellaneous Gray-Fiber.015" x 40" x 48" Sheeting Available from Lucent ( ) Miscellaneous Tape - Electrical UL Rated; Live Bus Bars Require Scotch 33 or 88 Miscellaneous NO-OX-ID "A" Anti-Corrosive Compound Available from SANCHEM Inc.; or Lucent #R3266 Miscellaneous NO-OX-ID "A-Special" Anti-Corrosive Available from SANCHEM Inc. Compound Miscellaneous 9/10/12 Multi-Ply Cord Battery Disconnect Battery Disconnect Switches Electric Equipment & Engineering CO. Order battery disconnect switches as a switch with shunt trip (no overcurrent protection). Consult TP76300, Table M-3 for number of conductors required prior to ordering disconnect switch so correct term plate can be ordered * Note: The list above covers the bulk of the minor material used for the installation of DC power distribution circuits. However, it is not possible to list the required components for every job variable. The Installation Supplier should follow the intent of this list to provide quality components that meet AT&T Installation and Engineering Requirements. (See TP Installation Requirements, and TP Engineering Requirements.) Page 20

Circuit protection for telecom applications

Circuit protection for telecom applications Telecom protection products 14 Contents Circuit protection for telecom applications Description Poles Volts DC Fused pullout disconnects and related fuses Amps Section page Compact TPCDS with TCP fuses

More information

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems Telpower DC Power Protection Systems Telpower Compact Fused Disconnect Switch TPC & TPCDS TPC & TPCDS TPCDS - Telpower Compact Fused Disconnect Switch TPC - Telpower Compact Fuse - Current Limiting Ampere

More information

Products. Section Contents

Products. Section Contents Telcom Protection Section Contents Page Telpower compact fused disconnect switches.....388 Telpower miniature fused disconnect switches.... 389 Fused disconnect switches for TPA fuses TP15914 4-Pole disconnect

More information

Fuse Panels, Fuse Holders and Fuses

Fuse Panels, Fuse Holders and Fuses DC Power Systems for Business-Critical Continuity Fuse Panels, Fuse Holders and Fuses 23" (58.42cm) Fuse Panels Description of Panels E/W Fuse Positions and Accessories Fuse Type Fuse Table Panel Height

More information

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES TELECOMMUNICATIONS SPECIAL PURPOSE FUSES Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment,

More information

Telecom Protection Products

Telecom Protection Products Telecom Protection Products Section Contents Page Telpower compact fused disconnect switches... 340 Telpower miniature fused disconnect switches... 341 Fused disconnect switches for TPA fuses TP15914 4-Pole

More information

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide, Part number 123518-6 Copyright 2010,

More information

Special Purpose Fuses

Special Purpose Fuses 70 series 70 SERIES Color Coded tip Rated 125V AC, 300V DC UL Recognized 125 VAC, 1000A I.R.; 300V DC, 1000A I.R. Guide JDYX2, File E39265 Continuous rated current is 80% of 10 minute (shown in table).

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version) SYSTEM OVERVIEW Description: +24VDC to -48VDC @ up to 375A converter system. The NetSure DCS48375 Converter System is comprised of a main shelf and up to two (2) expansion shelves. Each shelf provides

More information

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual Power :: 600CB10 and 600CB12 User Manual 600CB10 - Front View 600CB10-C - Rear View Applies to : 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C :: 600CB12-VL :: 600CB12-CL Table

More information

Fuse Panels, Fuse Holders and Fuses

Fuse Panels, Fuse Holders and Fuses Fuse Panel Assembly 23" (8.42cm) FUSE Description of Panels E/W Fuse Positions and Accessories Fuse Type PANELS Fuse Table Fuse Cabinet Assembly Panel Height 4316000 ( 4) 0- A, (16) Additional Positions

More information

Demarcation Fuse Alarm Panel

Demarcation Fuse Alarm Panel Installation Guide Applies to: 009-7001-0104 & 009-7001-0104-TFD Table of Contents 1.1 Overview...3 1.2 Inspection...3 1.3 Specifications...4 1.4 Installation...5 1.4.1 Important Installation Guidelines...5

More information

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08 Installation Guide Table of Contents 1.1 Overview... 2 1.2 Specifications... 3 1.3 Inspection... 3 1.4 Installation... 4 1.4.1 Important Installation

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing H-Tap Insulating Covers (Hard Covers) Interlocking insulating covers for H-type compression taps Easy installation: place the H-Tap in the cover and snap the cover closed Consult your Regional Sales Office

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide Installation Guide HPGMT10 / HPGMT10RC HPGMT15 / HPGMT15RC HPGMT10FA HPGMT10FA-1RU Applies to : HPGMT10 :: HPGMT10RC :: HPGMT10FA :: HPGMT10FA-1RU :: HPGMT15 :: HPGMT15RC Table of Contents 1.1 Overview...1

More information

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide, Part Number 123759-3 Copyright 2011, Telect,

More information

Insulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.

Insulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications. Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors

More information

Electrical. Hardware & Fastening Solutions. Battery Supplies. J-Case Fuses - Regular... Page 162

Electrical. Hardware & Fastening Solutions. Battery Supplies. J-Case Fuses - Regular... Page 162 Flag Style... Page 156 Electrical Batteries... Page 153 Mounting Pads (Adhesive Backed)... Page 161 Battery Supplies J-Case Fuses - Regular... Page 162 Booster Cable Supplies... Page 153 J-Case Fuses -

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

Dual-Feed 600A Load Center Frame

Dual-Feed 600A Load Center Frame Dual-Feed 600A Load Center Frame 600CB10 Front View 600CB10-C Rear View Installation Guide Part Number, 136429-2 Applies to: 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C ::

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing H-Tap Insulating Covers (Hard Covers) Interlocking insulating covers for H-type compression taps Easy installation: place the H-Tap in the cover and snap the cover closed Consult your Regional Sales Office

More information

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

BLADE TERMINAL AND SPECIAL PURPOSE FUSES BLADE TERMINAL AND SPECIAL PURPOSE FUSES LOW VOLTAGE ATO Fuse Fast-Acting Type U L Designed and originated by Littelfuse for the automotive industry, the ATO fuse has become the original equipment circuit

More information

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09) 1. Two marine electrical technicians are discussing conductor support. Tech A says that all conductors shall be supported throughout their length or at least every 18. Tech B says that there is an exception

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

Engineered installation products Solutions for control panel applications

Engineered installation products Solutions for control panel applications Engineered installation products Solutions for control panel applications 2 Engineered installation products Solutions for control panel applications Solutions for control panel applications ABB introduces

More information

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers Total Front Access Wall Mount Fuse Panel Installation Guide Document INS-7473121031 This manual covers the following part numbers- 7473121031 Table of Contents Section 1- General Information... 3 1.1 -

More information

GMT Fuse Panel Installation Guide

GMT Fuse Panel Installation Guide GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38

More information

CP 600V Cable Protectors

CP 600V Cable Protectors Protecrs Mersen CP Protecrs are special purpose limiters which are crimped or bolted cables or terminals clear and isolate faults quickly, increasing the reliability of service entrance and distribution

More information

Connector Installation Guide Compression and Mechanical Connectors

Connector Installation Guide Compression and Mechanical Connectors Connector Installation Guide Compression and Mechanical Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of

More information

September Cable termination solutions Lugs and tools for reliable crimping

September Cable termination solutions Lugs and tools for reliable crimping September 2016 Cable termination solutions Lugs and tools for reliable crimping ABB products are part of your success Designed to perform 1 2 3 4 5 7 6 7 8 1 Rail and transportation 2 Power utility and

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet Quick Term II Cold Shrink Silicone Rubber Termination Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 1 Hi K Silicone Rubber Termination 2 Scotch 70 Silicone

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified 0406-03E August 11, 2005 Fuse Panel Technical Practice N215120-NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified FEATURES Compatible with +24V, +48V, -24V or -48V dc input voltages (battery voltages). 2 busses

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

Reduce Downtime With Quick Access to the Right Replacement Fuse

Reduce Downtime With Quick Access to the Right Replacement Fuse Reduce Downtime With Quick Access to the Right Replacement Fuse Section Contents Page Fuse Service Kits Supplemental............................. 506-507 Branch circuit............................. 506-507

More information

10-32 x 1/2" PAN HEAD BOLT 14 PLACES, 7 PER BRACKET # 10/12 GROUND WASHER 2 PLACES, 1 PER BRACKET # 10 FLAT WASHER 12 PLACES, 6 PER BRACKET BRACKET, P/N 520295 2 PLACES RIGHT SIDE VIEW (LEFT SIDE SIMILAR)

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Step One Preparing the Cable Strip the insulation carefully to avoid nicking or cutting conductors

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

Heavy Duty Copper Battery Terminals

Heavy Duty Copper Battery Terminals Heavy Duty Copper Battery Terminals Constructed of 131 contact copper to provide high conductivity. Raised characters to ensure legibility of important information regarding cable size, post type, and

More information

:: :: TFD4 :: TFD6

:: :: TFD4 :: TFD6 User Manual Applies to: 007-0001-2600 :: 007-0001-2602 :: 007-0001-2602-TFD4 :: 007-0001-2602-TFD6 :: 007-0001-2602-4 :: 007-0001-2602-6 1 Table of Contents Chapter 1: Dual 600A BDFB/BDCBB Description...

More information

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!!

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!! & TRADING CO., INC. WWW.DYNATRONINDUSTRIES.COM AUTOMOTIVE ELECTRICAL SUPPLIES & TRADING CO., INC. 63 AUSTIN BLVD COMMACK NY 11725 TEL: (631)543-4490 FAX (631)543-4496 TOLL FREE: 1-800-669-3962 We carry

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

TPM/GMT Panel Installation Guide

TPM/GMT Panel Installation Guide TPM/GMT Panel Installation Guide Document INS-837xxxxxxx This manual covers the following part numbers- Trimm 837xxxxxxx Family Table of Contents Table of Contents... 2 Section 1- General Information...

More information

FUSE PANEL PRODUCT MANUAL

FUSE PANEL PRODUCT MANUAL FUSE PANEL PRODUCT MANUAL PM 990-2750-00, Issue 8 UNIPOWER, LLC 3900 Coral Ridge Drive Coral Springs, FL 33065 Phone: +1-954-346-2442 Toll Free: 1-800-440-3504 Web site http://www.unipowerco.com Fuse Panel

More information

Grounding Accessories

Grounding Accessories Accessories Eaton offers a variety of grounding which are sold individually or as a kit. Kits are available as one kit per rack, allowing for ease of stocking and reordering. Vertical rack ground bar kit

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present Installing the Base Plate 1. Examine the interior

More information

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family TPM Fuse Panel Installation Guide Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified 530-063 Rev K 0220-03K November 3, 202 Westell FUSE PANEL Technical Practice N25020-N-L33 0/0 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 0 GMT fuses in each (5Amps/GMT

More information

For a complete listing of kit contents, see page 225.

For a complete listing of kit contents, see page 225. HS 455 Shrink Tube Kit - microseries Sealing & securing can now be taken to go! Contains 55 6" pieces of single wall 2-1 polyolefin, flexible type. I.D. ranges 1 8"- 1 2" in red, black, yellow and blue.

More information

Application Note. Best Solutions for Managing High-Current Power Distribution

Application Note. Best Solutions for Managing High-Current Power Distribution Best Solutions for Managing High-Current Power Distribution High-Current Demarcation Panels Provide a Platform for Distribution & Protection M any of today s network applications include equipment that

More information

Small Terminals BURNDY

Small Terminals BURNDY B-14 TYPES T AND YAD HYLUG Uninsulated Compression Terminal, Ring Tongue The Type T uninsulated terminals are constructed of pure electrolytic copper. Designed a long brazed seam barrel, standard neck,

More information

100A/60A Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay Alarms Power :: HPGMTXX & GMTXX Installation Guide

100A/60A Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay Alarms Power :: HPGMTXX & GMTXX Installation Guide 100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Installation Guide pplies to : GMT10 :: GMT10F :: GMT20 :: GMT20S :: HPGMT10 :: HPGMT10F :: HPGMT15 :: HPGMT20 :: HPGMT20S

More information

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits. Electrical tapes for sealing, insulation and bundling of cable and conduits. HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC-

More information

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief) Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone

More information

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified

More information

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior

More information

GROUNDING & BONDING PRODUCTS

GROUNDING & BONDING PRODUCTS GROUNDING & BONDING PRODUCTS Busbars Page 5-3 Insulators Page 5-8 Grounding Products Page 5-9 Compression Tools, Lugs & Taps Page 5-14 Learn About CPI s Extended Limited Warranties for coverage of (2)

More information

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Instructions Kit Contents 3 Lug Covers 3 Cold Shrink Terminations 12

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Sta-Kon s Long Barrel Design

Sta-Kon s Long Barrel Design Terminals Why Sta-Kon Terminals Are Better Like any other value added manufacturing process, using the best material is only a start. Our Sta- Kon terminals are all manufactured with the customer in mind,

More information

UNSIGNED HARDCOPY NOT CONTROLLED

UNSIGNED HARDCOPY NOT CONTROLLED SUBJECT: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS Assembly Procedures Manager, Hardware Engineering Maintenance Revision Defines the requirements for assembly techniques and procedures that cannot

More information

Termco Lugs and Terminals

Termco Lugs and Terminals Termco Lugs and Terminals Copper Crimp Lugs and Links Pre- and Uninsulated Terminals and Connectors www.hesales.com.au Termco Lugs and Terminals Copper Lugs & HD Terminals All Termco Heavy Duty Copper

More information

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

Product Number

Product Number Sealing and Grounding Cold Shrink cable accessory sealing kits are designed to seal the end of JCN cable. Use these kits when installing elbows or other cable accessories that do not include a jacket seal.

More information

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n GT Nylon Cable Ties 4 GT Nylon Cable Ties - Color 5 GS Screw-Mount

More information

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV. INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Installation Instructions: DC6-48-60-0-8C-EV INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel

More information

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits 3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits With High Ampacity Ground Connection and High-K Stress Relief For Tape Shield, Wire-Over-Tape Shield and Longitudinally Corrugated (LC) Shield

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

Grounding Solutions for Data Center Applications

Grounding Solutions for Data Center Applications Grounding Solutions for Data Center Applications B D A A C E G F E Legend For Typical Grounding Application (layout on following page) A) B) C) D) E) F) G) Vertical Rack Ground Bar Kit (see page 4) Horizontal

More information

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 2000 2002 998 999 2004 200 200 2005 200 2008 207 2007 2009 200 20

More information

RELOC Modular Wiring Specialty Lighting and Power Systems

RELOC Modular Wiring Specialty Lighting and Power Systems RELOC Modular Wiring Specialty Lighting and Power Systems Family FileName Description RevisionDate Access Floor Wiring DB DB Distribution Box 10/15/1999 FM FMI3 Floor Module 03/15/2002 Power Wiring System

More information

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and

More information

MA-LINE TOOLS AND ACCESSORIES

MA-LINE TOOLS AND ACCESSORIES INDEX BRUSHES BOILER... 14-4 CLEANING... 14-4 COPPER TUBE... 14-3 NYLON TUBE... 14-3 WHISK CONDENSER FIN... 14-4 BUSHINGS ANTI-SHORT... 14-6 CAULKING GUN... 14-2 CHUCKS MAGNETIC... 14-3 COPPER TUBE EXTENSIONS

More information

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part# Installation Manual AC Edge Split Phase 60 A (6/6) AC Power Distribution Unit AC Edge Model AC60DF 6/6 Part# 1101-1071 1402-036 RevE Installation Manual AC Edge Table of Contents AC Edge Introduction 3

More information

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 5/8.7 kv Class 95 kv BIL Kit Contents: 3 Hi K, Tracking Resistant,

More information

WE MAKE PRODUCTS THAT MAKE A DIFFERENCE 12070 Burke Street Santa Fe Springs, CA 90670 Fax: 800-597-7757 B-FE-0509 www.phillipsind.com ABS LECTRACOIL 5 YEAR WARRANTY Assembly Only See website for details

More information

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit 3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7622-T-110, 7624-T-110, 7625-T-110, 7626-T-110 Instructions

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254. 3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200

More information

circuit protection & wiring accessories

circuit protection & wiring accessories circuit protection & wiring accessories CIRCUIT BREAKERS P1 P BLOCKS & BUSBARS TERMINAL BLOCKS P2 P3 CONNECTORS, TERMINALS & FUSES P4 CLAMPS, CLEATS, CLIPS & TIES P5 P1 circuit protection & wiring accessories

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

MR Gradient Cable Field Termination Training

MR Gradient Cable Field Termination Training MR Gradient Cable Field Termination Training Field Service Training DOC2081583 Imagination at work Brian Gracyalny 212473777 MR Service Engineering Overview The purpose of this training is to make the

More information

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief 3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7621-T-95, 7622-T-95, 7624-T-95, 7625-T-95 Instructions IEEE Std.

More information