Fuse Panels, Fuse Holders and Fuses

Size: px
Start display at page:

Download "Fuse Panels, Fuse Holders and Fuses"

Transcription

1 DC Power Systems for Business-Critical Continuity Fuse Panels, Fuse Holders and Fuses 23" (58.42cm) Fuse Panels Description of Panels E/W Fuse Positions and Accessories Fuse Type Fuse Table Panel Height Notes Wrap & Solder Load Term (4) 0-5 A 70 A 1-3/4" (4.45cm) 2, Ga Load Term* (20-20) 0-10 A Split Load (20 A Max Per Side) Load & Grd. Rtn. Term Blocks GMT B 3/4" (1.91cm) 5 Wire Wrap Load Term (50) 0-10 A (Accessory Grd. Bar ) GMT B 3-1/2" (8.89cm) 5 1/4" (.64cm) Stud Load Term (16) 0-60 A TPS C 7" (17.78cm) 3/4" (1.91cm) Stud ( A), 7/8" (2.23cm) Stud ( A) Load Term** (1) A TPL E 5-1/4" (13.34cm) (1) A E/W A 400 A Shunt TPL E 5-1/4" (13.34cm) (2) A TPL E 7" (17.78cm) (2) A E/W (2) 400 A Shunts TPL E 7" (17.78cm) (2) A A/F (2) Shunts & Ammeters TPL E 7" (17.78cm) 9, (4) A TPL E 10-1/2" (26.67cm) (1) A TPL E 5-1/4" (13.34cm) (1) A E/W A 600 A Shunt TPL E 5-1/4" (13.34cm) (2) A TPL E 7" (17.78cm) (2) A E/W (2) 600 A Shunt TPL E 7" (17.78cm) (2) A A/F (2) Shunts & Ammeters TPL E 7" (17.78cm) 9, (4) A TPL E 10-1/2" (26.67cm) (1) A Fuse Switch Unit TPL E 7" (17.78cm) (2) A Fuse Switch Unit TPL E 12-1/4" (31.12cm) (1) A Fuse Switch Unit A/F Ammeter and Shunt TPL E 7" (17.78cm) 9, 11 Lug Adpt. Load Term (1) 800-1,200 A KRPC F 5-1/4" (13.34cm) 12, (1) 800-1,200 A Fuse Switch Unit W/WO Shunt KRPC F 12-1/4" 12, 14 * Lugs not required ** See Table M 1

2 19" (48.26cm) Fuse Panels Description Fuse Type Fuse Table Panel Height Notes Wrap & Solder Load Term (4) 0-5 A 70 A 1-3/4" (4.45cm) 2, 8 Wire Wrap Load Term (40) 0-10 A (Accessory Grd. Bar ) GMT B 3-1/2" (8.89cm) (20-20) 0-10 A Split Load (Accessory Grd. Bar ) GMT B 3-1/2" (8.89cm) 5 Term Block #6 Screw Load Term (10-10) 0-10 A Split Load GMT B 1-3/4" (4.45cm) 5, Ga Load Term* (20-20) 0-10 A Split Load (20 A Max Per Side) Load & Grd. Rtn. Term Blocks GMT B 1-3/4" (4.45cm) 5 1/4" (.63cm) Stud Load Term (12) 0-60 A TPS C 7" (17.78cm) Lug Adpt. Load Term (1) A TPL E 5-1/4" (13.34cm) (1) A TPL E 5-1/4" (13.34cm) 15 Rear Fuse Cabinet Assembly ( ) 2

3 Rear amp Fuse Panel Rear amp Fuse and Switch Distribution Panel 3

4 Side Rear Battery Load Alarm 0 5 amp Twin Fuse Block (70 Type) Side Alarm Battery Load 0 10 amp Fuse Block (GMT type) Side amp Fuse Block (bolt-in type) Side TPS Fuseholders 4

5 A) 70 Type Fuse B) GMT Type Fuse C) TPS / TLS Type Table A: 70 Type 70 Type Designation Pins amp Capacity Color Yellow Violet * Violet/White Red Brown White Orange Blue Green Table B: GMT Type amp Capacity Color Violet Red Brown White Orange Blue Brown/White Green Red/White Dummy Safety Cover Table C: TPS / TLS Type amp Capacity TPS Type Bussmann GMT-A ALM Fuse for Use with TPS Holders Safety Cover

6 D) TPN Type 1 30 amp D) TPN Type amp Table D: TPN Type amp Capacity Top End E) TPL Type Table E: TPL Type amp Capacity F) KRP-C Type Table F: KRP-C Type amp Capacity

7 Table G: Ammeters & Shunts amp Ammeter Shunt Part Capacity Number Table H: Ammeters & Shunts amp Ammeter Shunt Part Capacity Number Table I: Shunts amp Capacity Shunt Table J: Bus Bars Number of Fuse Blocks Connected Table K: Lugs and Adapters Description Adapter E/W (1) 2-4/0 saddle lug (1) 0-500MCM saddle lug (1) MCM saddle lug Adapter E/W (2) 1/0-500MCM saddle lugs Adapter for crimp lugs 3/8" (.95cm) hardware (1" [2.54cm] C-C) or 1/2" (1.27cm) hardware (1-3/4" [4.45cm] C-C)

8 Application Notes 1. Unless otherwise specified (Notes 2, 7 & 12), an alarm LED card part number , for use with power board equipment with a fuse alarm circuit, is furnished as standard. When no power board alarm circuit is available and an alarm LED and relay is required, specify panel e/w optional alarm LED and relay card part number Specify voltage and polarity. 2. This assembly is equipped with an alarm LED and relay card part number If not required, it may be replaced with a alarm LED card. Specify voltage and polarity. 3. These fuse panel assemblies can be used for ±12, 24, 48 OR 130 volt applications unless otherwise specified (Note 5). 4. Apparatus mounting blanks are provided for all unequipped positions. 5. To be used up to 60 Volt DC only. 6. Contact Emerson Network Power for additional information concerning any specific fuse panel. Specify part number and request assembly drawing. 7. This assembly has an alarm relay and lamp arranged for ± 24 or 48 volt only. Specify voltage and polarity. 8. When a special arrangement is required, specify additional quantity of twin fuse block(s), part number and busbar(s) required per Table J. 9. Unless otherwise specified, output lugs and lug adapters are not provided, order from Table K and lug tables in this catalog per job requirements. 10. Ammeters and shunts are not furnished with assembly and must be ordered from Table J per job requirements. 11. Ammeters and shunts are not furnished with assembly and must be ordered from Table I per job requirements. 12. This assembly is equipped with a fuse alarm resistor tapped for 250, 500 or 2,500 ohms for connection to a fuse alarm relay circuit. 13. Lug adapters are not part of this assembly, order (1) or (2) part number lug adapter (A/F 3/8" (.95cm) HDW 1" [2.54cm] C-C or 1/2" [1.27cm] HDW 1-3/4" [4.45cm] C-C ). Order (1) part number busbar for fuse to discharge bus when required. 14. Assembly is furnished with a lug adapter A/F (3)sets of mounting holes 3/8" (.95cm) HDW 1" (2.54cm) C-C. When a shunt is required, order assembly equipped with a shunt mounting block part number and shunt from Table I as required. 15. Assembly is furnished with (2) lug adapters A/F (2) sets of mounting holes 3/8" (.95cm) HDW 1" (2.54cm) C-C and (1) set of mounting holes 1/2" (1.27cm) HDW 1-3/4" (4.45cm) C-C. How To Order 1. Specify part number for 19" (48.26cm) or 23" (58.42cm) fuse panel assembly as required. 2. Specify part number and quantities of fuses, shunts, lug adapters and other accessories from associated tables and application notes as required. 3. S pecify quantity and part number of lugs and adapters required (see Table K or the Ground Bars, Terminal Panels & Lugs data sheet from Accessories). Emerson Network Power. The global leader in enabling businesscritical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Outside Plant Integrated Cabinet Solutions Precision Cooling Site Monitoring and Services 2005 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson Network Power Energy Systems 1122 F St. Lorain, OH Toll Free: (USA and Canada) Telephone: Fax: Web: EmersonNetworkPower.com/EnergySystems This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Vortex, Candeo and LORAIN are trademarks of Emerson Network Power Energy Systems, North America, Inc. 8 Printed in USA

Fuse Panels, Fuse Holders and Fuses

Fuse Panels, Fuse Holders and Fuses Fuse Panel Assembly 23" (8.42cm) FUSE Description of Panels E/W Fuse Positions and Accessories Fuse Type PANELS Fuse Table Fuse Cabinet Assembly Panel Height 4316000 ( 4) 0- A, (16) Additional Positions

More information

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A) NetSure 5100 ORDERING GUIDE 48V & 24V DC Power System (40 A to 600 A) NETSURE 5100 ORDERING GUIDE Description The NetSure 5100 Series, a compact -48 volt 600 A DC power solution, features an advanced control

More information

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers WHEEL MONITOR CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers Installation Manual for the CTC-400 Cab and Trailer Modules Wheel Monitor Inc. 1-905-641-0024

More information

FUSE PANEL PRODUCT MANUAL

FUSE PANEL PRODUCT MANUAL FUSE PANEL PRODUCT MANUAL PM 990-2750-00, Issue 8 UNIPOWER, LLC 3900 Coral Ridge Drive Coral Springs, FL 33065 Phone: +1-954-346-2442 Toll Free: 1-800-440-3504 Web site http://www.unipowerco.com Fuse Panel

More information

10-32 x 1/2" PAN HEAD BOLT 14 PLACES, 7 PER BRACKET # 10/12 GROUND WASHER 2 PLACES, 1 PER BRACKET # 10 FLAT WASHER 12 PLACES, 6 PER BRACKET BRACKET, P/N 520295 2 PLACES RIGHT SIDE VIEW (LEFT SIDE SIMILAR)

More information

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity NetSure 701 Series DC Power System DC Power for Business-Critical Continuity Key Features High Efficiency approaching 97%, esure rectifiers reduce power consumption for lower operating costs Modular Design

More information

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems Telpower DC Power Protection Systems Telpower Compact Fused Disconnect Switch TPC & TPCDS TPC & TPCDS TPCDS - Telpower Compact Fused Disconnect Switch TPC - Telpower Compact Fuse - Current Limiting Ampere

More information

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity NetSure 701 Series DC Power System DC Power for Business-Critical Continuity Key Features n n High Efficiency approaching 97%, esure rectifiers reduce power consumption for lower operating costs Modular

More information

Circuit protection for telecom applications

Circuit protection for telecom applications Telecom protection products 14 Contents Circuit protection for telecom applications Description Poles Volts DC Fused pullout disconnects and related fuses Amps Section page Compact TPCDS with TCP fuses

More information

CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers WHEEL MONITOR CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers Installation Manual for the CTC-200 Modules 2004 Wheel Monitor Inc. 1-905-641-0024 Page

More information

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide, Part number 123518-6 Copyright 2010,

More information

Products. Section Contents

Products. Section Contents Telcom Protection Section Contents Page Telpower compact fused disconnect switches.....388 Telpower miniature fused disconnect switches.... 389 Fused disconnect switches for TPA fuses TP15914 4-Pole disconnect

More information

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version) SYSTEM OVERVIEW Description: +24VDC to -48VDC @ up to 375A converter system. The NetSure DCS48375 Converter System is comprised of a main shelf and up to two (2) expansion shelves. Each shelf provides

More information

Product Manual Select Code Comcode Issue 9 September Secondary DC Power Distribution Bay H

Product Manual Select Code Comcode Issue 9 September Secondary DC Power Distribution Bay H Product Manual Select Code -00- Comcode 0 Issue September 00 Secondary DC Power Distribution Bay H- Product Manual Select Code -00- Comcode 0 Issue September 00 Secondary DC Power Distribution Bay H-

More information

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES TELECOMMUNICATIONS SPECIAL PURPOSE FUSES Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment,

More information

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide, Part Number 123759-3 Copyright 2011, Telect,

More information

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified 0322-03D Sept 02, 2010 Noran Tel FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 5 GMT fuses each (20Amps/GMT position). Polarity

More information

ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/

ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/ GROUNDING CABLE/MATERIAL Contact: John Messina (203) 553-0232 CABLE/WIRE: Class B - Standard Strand (Type 3 Braid) CABLE/WIRE 14 AWG-Stranded RHH 90C Rated Dry/Damp & 60C Wet, Braid CABLE/WIRE 12 AWG-Stranded

More information

Telecom Protection Products

Telecom Protection Products Telecom Protection Products Section Contents Page Telpower compact fused disconnect switches... 340 Telpower miniature fused disconnect switches... 341 Fused disconnect switches for TPA fuses TP15914 4-Pole

More information

5067 Mini BDFB / BDCBB

5067 Mini BDFB / BDCBB PRODUCT OVERVIEW 5067 Mini BDFB / BDCBB Up to 4 Loads, 600 Amps per Load Compact unit can be placed at the point of load High density models available with 48 circuits in 16RU Digital metering, extended

More information

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS Instruction Manual Copyright, Athena Controls, Inc., 2006 Printed in USA CompuStep is a registered trademark of Athena Controls, Inc. SafeChange is a trademark

More information

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified 530-101732 Rev L 0223-03K September 30, 2010 Westell FUSE PANEL Technical Practice N250140-N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 20 GMT fuses each (15Amps/GMT

More information

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay Product Manual Part Number: 438 5068PD Issue 32, March 2010 Engineer: H. D. Approved: H. D. PECO II, Inc. 1376 State Route 598 Galion, OH

More information

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Content PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual Page INTRODUCTION...2 Revision History...5 Trademark Information...5 Admonishments...5 General Safety Precautions...6

More information

TPM/GMT Panel Installation Guide

TPM/GMT Panel Installation Guide TPM/GMT Panel Installation Guide Document INS-837xxxxxxx This manual covers the following part numbers- Trimm 837xxxxxxx Family Table of Contents Table of Contents... 2 Section 1- General Information...

More information

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified 530-063 Rev K 0220-03K November 3, 202 Westell FUSE PANEL Technical Practice N25020-N-L33 0/0 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 0 GMT fuses in each (5Amps/GMT

More information

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified 0406-03E August 11, 2005 Fuse Panel Technical Practice N215120-NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified FEATURES Compatible with +24V, +48V, -24V or -48V dc input voltages (battery voltages). 2 busses

More information

Special Purpose Fuses

Special Purpose Fuses 70 series 70 SERIES Color Coded tip Rated 125V AC, 300V DC UL Recognized 125 VAC, 1000A I.R.; 300V DC, 1000A I.R. Guide JDYX2, File E39265 Continuous rated current is 80% of 10 minute (shown in table).

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans

CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans , CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans Lay the C.A.E Engine loom in vehicle and plug in all the sensors. ( The sensor plugs can only be connected one way

More information

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

BLADE TERMINAL AND SPECIAL PURPOSE FUSES BLADE TERMINAL AND SPECIAL PURPOSE FUSES LOW VOLTAGE ATO Fuse Fast-Acting Type U L Designed and originated by Littelfuse for the automotive industry, the ATO fuse has become the original equipment circuit

More information

Type SJK Test Switches

Type SJK Test Switches Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES

More information

Fuse / Circuit Breaker Panels

Fuse / Circuit Breaker Panels Critical Power from GE Micro-BDCBB DC Battery Distribution Circuit Breaker Bay Overview The GE Micro-BDCBB serves as a secondary power distribution center for +24Vdc or -48Vdc DC power delivered from a

More information

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual Power :: 600CB10 and 600CB12 User Manual 600CB10 - Front View 600CB10-C - Rear View Applies to : 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C :: 600CB12-VL :: 600CB12-CL Table

More information

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes 0113-03K September 2, 2010 FUSE PANEL Technical Practice NTI-N250140-NC(Y)/M3 NEBS Level 3 Certified NTI-230140-NCD(Y)/M3 Standard Panel with Diodes FEATURES ƒ Negative (-) VDC input voltage, -24 or 48Vdc

More information

twin engine two battery bank split charge system

twin engine two battery bank split charge system twin two battery bank split charge system P2331 12 volt. P2331 part number. 12331-0 24 volt. P2341 part number. 12341-0 contactor current rating continuous... 0 amp @ mv / contact / 0 A start... 0 amp

More information

Secondary DC Distribution

Secondary DC Distribution GE Critical Power Secondary DC Distribution -48V Battery Distribution Bay 24 Inches Deep, BDFB / BDCBB Overview The GE Battery Distribution Fuse Bay (BDFB) or Battery Distribution Circuit Breaker Bay (BDCBB)

More information

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512 10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits 51404974-501 through -512 Document Number Form: 62-86-33-16D Effective: 3-1-01 Supersedes: 11-00 Summary Retrofitting your 10260 actuator from

More information

No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have

More information

PowerWorx DSX Series GMT Fuse Panel User Manual

PowerWorx DSX Series GMT Fuse Panel User Manual PowerWorx DSX Series GMT Fuse Panel User Manual ADCP-80-538 Issue 4 2/2012 1206873 Rev E Preface COPYRIGHT 2011, Tyco Electronics Corporation All Rights Reserved REVISION HISTORY ISSUE DATE REASON FOR

More information

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08 Installation Guide Table of Contents 1.1 Overview... 2 1.2 Specifications... 3 1.3 Inspection... 3 1.4 Installation... 4 1.4.1 Important Installation

More information

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER File: 091-165-12-DV_revD.PDF Rev: D, Date: 02-25-16 INSTRUCTION MANUAL AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER MODEL #091-165-12-DV INPUT: 115 or 230VAC, 50/60Hz OUTPUT: 13.2VDC (nom.), 12 Amperes

More information

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds Description: Very easy to build, The FK109 Led Flasher kit makes the perfect

More information

LAB 7. SERIES AND PARALLEL RESISTORS

LAB 7. SERIES AND PARALLEL RESISTORS Name: LAB 7. SERIES AND PARALLEL RESISTORS Problem How do you measure resistance, voltage, and current in a resistor? How are these quantities related? What is the difference between a series circuit and

More information

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications NterpriseIP Solution Adaptive, high-availability power system for IP Telephony Business-Critical Continuity for Communications Deploy, Integrate, and Expand VoIP and PoE Applications More Quickly, Reliably

More information

VSM V-COUNT II are registered trademark of APEXS, Inc.

VSM V-COUNT II are registered trademark of APEXS, Inc. Applied Expert Systems Inc. (APEXS, Inc.). 2003.All rights reserved VSM V-COUNT Vehicle Speed Sensor (VSS) Installation Guide VSM V-COUNT II are registered trademark of APEXS, Inc. VSS Installation Guide

More information

Fuse and Distribution Module

Fuse and Distribution Module Charles Industries, Ltd. Section 428 500 204 Equipment Issue 4 Fourth Printing, July 1999 4285 00 Fuse and Distribution Module CLEI Code: PWPQW021AA CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

GMT Fuse Panel Installation Guide

GMT Fuse Panel Installation Guide GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

ches UL File No. E101598

ches UL File No. E101598 Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the

More information

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified 0521-03A May 2006 FUSE PANEL Technical Practice FDP 1010 10/10 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 10 GMT fuses in each (15Amps/GMT position) Polarity insensitive (+/-24 or

More information

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified 1107-03B Aug 16, 2011 a subsidiary of Westell Inc Fuse Panel Technical Practice NPGMT1107 10/10 GMT NEBS Level 3 Verified FEATURES 2 isolated groups (busses) of 10 GMT style fuses in each (20Amps/GMT position

More information

TIP SHEET T0491. Installation Tips for your Excalibur RS Passlock-sl2(4) + DLRC + SPDT

TIP SHEET T0491. Installation Tips for your Excalibur RS Passlock-sl2(4) + DLRC + SPDT TIP SHEET T0491 Installation Tips for your Excalibur RS-360 + Passlock-sl2(4) + DLRC + SPDT For Chevrolet: Astro 1998-2005, Avalanche 2002, Blazer 1998-2005, Cavalier 2000-2003, Express Van 1998-2005,

More information

:: :: TFD4 :: TFD6

:: :: TFD4 :: TFD6 User Manual Applies to: 007-0001-2600 :: 007-0001-2602 :: 007-0001-2602-TFD4 :: 007-0001-2602-TFD6 :: 007-0001-2602-4 :: 007-0001-2602-6 1 Table of Contents Chapter 1: Dual 600A BDFB/BDCBB Description...

More information

Method Of Procedure For Retrofitting ECS Power Systems (CC )

Method Of Procedure For Retrofitting ECS Power Systems (CC ) For Retrofitting ECS Power Systems (CC848791491) Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is

More information

750 Paso Wiring Upgrade

750 Paso Wiring Upgrade 750 Paso Wiring Upgrade Supplies required: 2 Bosch 30A/12V Relays # #0 332 209 150 (with mounting tab) 1 30 Amp fuse holder 1 10 Amp fuse holder 12 inches of brown 12 gauge wire 60 inches of red 14 gauge

More information

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L224-48V to +24V, L225 +24V to -48V Edge Controller example Outputs RTNs Inputs RTNs Refer to Infinity Converter Brochure

More information

Demarcation Fuse Alarm Panel

Demarcation Fuse Alarm Panel Installation Guide Applies to: 009-7001-0104 & 009-7001-0104-TFD Table of Contents 1.1 Overview...3 1.2 Inspection...3 1.3 Specifications...4 1.4 Installation...5 1.4.1 Important Installation Guidelines...5

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012

Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012 Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing remote starts

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

Technical Information and Diagnostic Guide

Technical Information and Diagnostic Guide Technical Information and Diagnostic Guide This guide will assist you in becoming more familiar with the working components of the NITE System and the proper steps and procedures to completely diagnose

More information

ECHO 8 Kit - Installation Manual

ECHO 8 Kit - Installation Manual ECHO 8 Kit - Installation Manual P/N: 20 2900 81 0828 0A SUBJECT: BENEFITS: EBERSPAECHER CARGO HEAT OPTION (D8LC) Provides comfort heat for working vans and trucks. Protects valuable loads from low temperatures.

More information

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S ) Capacitors MN230005EN Effective November 2016 Supersedes November 2001 (S230-30-3) Expulsion fuse installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The

More information

MAIN INCOMER -1 (500 KVA TRF.)

MAIN INCOMER -1 (500 KVA TRF.) Sr.No. DESCRIPTION MAKE QTY 1 MAIN L.T.PANEL Design, fabrication assembling, supply, installation, testing and commissioning of cubicale type LT panels floor mounted free standing suitable for 415 V 3

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL www.unipowerco.com Manual No. BDP600-2 bdp600-man-rev2-0416.indd 2016 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs, Florida

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

General Purpose Flasher Circuit

General Purpose Flasher Circuit General Purpose Flasher Circuit By David King Background Flashing lights can be found in many locations in our neighbourhoods, from the flashing red light over a stop sign, a yellow warning light located

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Installation Tips for your GMDLBP + Excalibur Remote Start system (for GM vehicles) v1.01 updated 10/09/13

Installation Tips for your GMDLBP + Excalibur Remote Start system (for GM vehicles) v1.01 updated 10/09/13 Installation Tips for your GMDLBP + Excalibur Remote Start system (for GM vehicles) v1.01 updated 10/09/13 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing

More information

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED 1. ENCLOSURE REQUIRED If the OC1 control is furnished as an open-chassis unit (standard), mount control in an enclosure 12 x 10 x 5 or larger and mount enclosure where room temperature does not exceed

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

Table No. 1 provides a means of identifying the various alternator systems. Note: All output figures are rated at 3600 RPM. TABLE NO.

Table No. 1 provides a means of identifying the various alternator systems. Note: All output figures are rated at 3600 RPM. TABLE NO. The alternator systems installed on Briggs & Stratton Intek OHV-Twin Cylinder Engines can easily be identified by the color of the stator output wires and the connector. Table No. 1 provides a means of

More information

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified 0522-03A May 2006 FUSE PANEL Technical Practice FDP 2020 20/20 GMT NEBS Level 3 Certified FEATURES Polarity insensitive (+/-24 or +/-48 Vdc) battery voltage This panel can operate at 200 Amps of output

More information

Central Locking Diagrams

Central Locking Diagrams Central Locking Diagrams DIAGRAM N. 2 CLOSURE TIME 0,5 SECONDS. +30 COMMON (Positive or Negative) OPEN CLOSE DIAGRAM N. 3 CLOSURE TIME 6 SECONDS. +30 COMPRESSOR ORIGINAL ACTUATOR DIAGRAM N. 4 CLOSURE TIME

More information

Dual-Feed 600A Load Center Frame

Dual-Feed 600A Load Center Frame Dual-Feed 600A Load Center Frame 600CB10 Front View 600CB10-C Rear View Installation Guide Part Number, 136429-2 Applies to: 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C ::

More information

USB Charge Port Installation Instructions

USB Charge Port Installation Instructions USB Charge Port Installation Instructions Lifetime Technical Support support@logolites.com 770-476-7322 www.logolites.com Manual 100-0014C Thank you for purchasing a Logo Lites USB Charge Port! USB Charge

More information

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating 530-101760 REV C 0808-03C December 7, 2012 Westell FUSE PANEL Technical Practice 180108-N-0808 8 Position Type 70 130 VDC Floating FEATURES Single floating input distributing power via Type-70 fuses each

More information

SCA-80(Q) C11 REPLACEMENT ASSEMBLY MANUAL

SCA-80(Q) C11 REPLACEMENT ASSEMBLY MANUAL SCA-80(Q) C11 REPLACEMENT ASSEMBLY MANUAL 2014-2016 AkitikA, LLC All rights reserved Revision 1p05 July 3, 2016 Page 1 of 15 Table of Contents Table of Contents... 2 Table of Figures... 2 Section 1: About

More information

Power Distribution Units

Power Distribution Units Power Distribution Units AP9562, AP9563, and AP9564 AP9562, AP9563, and AP9564 are 15- and 20-amp Rack Power Distribution Units (PDUs) that provide 120-volt power to rack-mounted equipment. AP9562, -.,

More information

Section 6: Parts Data

Section 6: Parts Data Section 6: Parts Data 39 25 5 18 1 11 8 10 3 4 9 23 22 12 13 11 15 14 19 7 5 21 10 6 20 3 4 21 20 40 Section 6: Parts Data CABINET GROUP * 9960-256-033 Door Assy., Loading Complete-Alm...2 * 9960-256-032

More information

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation Overview Alternator Identification Page 1 of 3 The alternator systems installed on Briggs & Stratton Intek V-Twin Cylinder OHV Engines can easily be identified by the color of the stator output wires and

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide Installation Guide HPGMT10 / HPGMT10RC HPGMT15 / HPGMT15RC HPGMT10FA HPGMT10FA-1RU Applies to : HPGMT10 :: HPGMT10RC :: HPGMT10FA :: HPGMT10FA-1RU :: HPGMT15 :: HPGMT15RC Table of Contents 1.1 Overview...1

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

Application Note. Best Solutions for Managing High-Current Power Distribution

Application Note. Best Solutions for Managing High-Current Power Distribution Best Solutions for Managing High-Current Power Distribution High-Current Demarcation Panels Provide a Platform for Distribution & Protection M any of today s network applications include equipment that

More information

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012 Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing

More information

Product Manual Select Code Comcode Issue 4 April Lucent Technologies. Lineage 2000 Battery Plant J85500A-2

Product Manual Select Code Comcode Issue 4 April Lucent Technologies. Lineage 2000 Battery Plant J85500A-2 Product Manual Select Code 167-790-032 Comcode 108190596 Issue 4 April 1999 1999 Lucent Technologies Lineage 2000 Battery Plant J85500A-2 Product Manual Select Code 167-790-032 Comcode 108190596 Issue

More information

Type MTS Miniature Test Switches

Type MTS Miniature Test Switches Type MTS Miniature Test Switches o o o o Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL DESCRIPTION In many panelboard, switchgear, metering,

More information

Single pole connectors

Single pole connectors Cam-Lok J-Series E1016 receptacles Cable Size #6 AWG 250 MCM 600V AC/DC, Up to 400A Continuous NEMA 3R J-Series E1016, elastomeric, threaded stud Double cam principle provides a positive, vibration-proof

More information

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family TPM Fuse Panel Installation Guide Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

Remote Starter Integration for the 2007 Toyota Camry equipped with the Smart Key System with Push Button Start

Remote Starter Integration for the 2007 Toyota Camry equipped with the Smart Key System with Push Button Start Remote Starter Integration for the 2007 Toyota Camry equipped with the Smart Key System with Push Button Start 1.0 Material required: - Remote Car Starter - Xpresskit : XK05-PKT2 or Bypasskit :PKT2 - One

More information

Shaved-B. Installation Manual & Operation Instructions

Shaved-B. Installation Manual & Operation Instructions Shaved-B Installation Manual & Operation Instructions Each Kit Contains The Following Components (1) Receiver (2) Remotes (2) Wire Harnesses Installation Instructions for SPAL Shaved Door Handle Kit Shaved-40

More information

Western Products, PO Box , Milwaukee, WI Hopper Spreader. Control Wiring and Electrical Components

Western Products, PO Box , Milwaukee, WI Hopper Spreader. Control Wiring and Electrical Components Western Products, PO Box 2403, Milwaukee, WI 3224-3 www.westernplows.com August 1, 201 Lit. No. 201, Rev. 0 Hopper Spreader Control Wiring and Electrical Components Installation Instructions and Parts

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

MOTOALLIANCE WINCH MOUNT

MOTOALLIANCE WINCH MOUNT , / 1-866-527-7637 www.motoalliance.com MOTOALLIANCE WINCH MOUNT Polaris RZR Thank you for purchasing our MotoAlliance winch mount(s). You now own a premium custom winch mount to allow you to use your

More information