Panelboards. Panelboards Electrical Aftermarket Products and Services 4-1. Contents

Size: px
Start display at page:

Download "Panelboards. Panelboards Electrical Aftermarket Products and Services 4-1. Contents"

Transcription

1 March 00 Aftermarket Solutions, Ref. No. [] - CA000E Contents Description Page Product Description Product History Product History Time Line CDP P PB/PH/PH-L MP EE EP PRL and PRL PRLa and PRLa PRL PRLa PRLB PRLF Technology Upgrades Clipper Power System Visor Series Pow-R-Command Panelboard Retrofits Product Support Services Satellite Locations Further Information Pricing Information Westinghouse PRL 0

2 - March 00 Aftermarket Solutions, Ref. No. [0] Product Description and switchboards are enclosed assemblies for lighting and distribution that accept incoming power and consist of a series of circuit breakers and/or fusible switches. These devices protect each circuit by providing overcurrent and short circuit protection. Product History In, Eaton Corporation acquired the Distribution and Control Business Unit (DCBU) of Westinghouse and integrated it with their Cutler-Hammer business unit forming a powerful new combination. This product history tracks the evolution of panelboard and switchboard products for both manufacturers. Cutler-Hammer NFB Westinghouse P In the 0s, prior to the development of circuit breakers, Westinghouse sold panelboards designed for main and branch circuit fuses. Circuit breakers were first introduced in and put Westinghouse in the forefront of circuit breaker technology. A few years later the first Westinghouse NOFUSE circuit breakers were introduced. NOFUSE panelboards were initially available in ratings up to amperes at 0 volts. were designed at higher ratings as circuit breakers ratings became available. By, panelboards were available at ratings up to 00 amperes and 00 volts. Cutler-Hammer MP0 Westinghouse Pow-R-Line 0 The most significant panelboard types were the CDP and P panels. For more than years, these two types encompassed most Westinghouse molded case circuit breakers and fusible switches. In, Eaton s electrical business entered the panelboard and switchboard market with the purchase of Mullenbach. Soon after the Mullenbach acquisition, Cutler-Hammer entered into an agreement with Westinghouse to supply breakers and fusible devices for panelboards and switchboards, and Eaton also began manufacturing Westinghouse-type panelboards under the agreement. This relationship made in the early 0s provided users of both trade name products access to aftermarket service for add-on branch devices and hardware. Classic Cutler- Hammer panelboards and switchboards were designed and listed for use with Westinghouse breakers. Cutler-Hammer CHB Cutler-Hammer EE Westinghouse WEB Westinghouse CDP CA000E

3 March 00 Aftermarket Solutions, Ref. No. [] - Product History (Continued) In, Westinghouse redesigned the panelboard and switchboard line to incorporate the new Series C design breakers. This new design became a true family of products. These new panelboards and switchboards became today s Pow-R-Line family Product History Time Line - Westinghouse AB Westinghouse NM/NMM - Westinghouse NAB - Westinghouse NLAB - Westinghouse NAB - Westinghouse ABH - Westinghouse NDP - Cutler-Hammer CDP - Westinghouse CDP/P - Westinghouse NQB/NQC/NQP - Westinghouse NEB/NHEB - Westinghouse WCA/WEB/WEHB/ WFB/WGB/WGHB - Cutler-Hammer CHP/CHB - Cutler-Hammer NFB - Cutler-Hammer MP0/MP0 - Westinghouse BB/QP - Cutler-Hammer PB - Cutler-Hammer PH - Cutler-Hammer EE - Westinghouse WB/WP - Cutler-Hammer EP - Westinghouse PRL - Westinghouse PRL, PRL - Cutler-Hammer PRLa, a - Cutler-Hammer PRLa - Westinghouse PRLB, F - Cutler-Hammer PRLP Figure -. Product History Time Line which are manufactured in state-ofthe-art facilities strategically located throughout the United States. Eaton unique Satellite Plants support aftermarket services for all current Pow-R-Line panelboard and switchboard products. Aftermarket service for out-of-production panelboards and switchboards for both the classic Westinghouse and Cutler-Hammer designs is supported by the Aftermarket Center in Sumter, SC (see Page -) and is staffed with experienced and knowledgeable representatives. Page Product Present 0 CA000E

4 - March 00 Replacement Chart Aftermarket Solutions, Ref. No. [] 0 How to Select Replacement s A complete line of new, UL listed products, physically and electrically interchangeable molded case circuit breakers is offered by Eaton. To properly select the breaker for your existing panelboard:. Identify the panel type and existing branch breaker.. Select the appropriate breaker from the direct replacement solution column. As shown, three options are available. Option : Series C breakers are available as direct replacement for installation in Cutler-Hammer panelboards. They are available at your local distributors and are the most economical solution. Option : Original, but still-inproduction breakers, (sometimes referred to as replacement breakers) are available from Cutler-Hammer national warehouses. These are identical to the existing branch breakers. Option : Panelboard replacement breakers, available for out-of-production molded case breakers, are physically and electrically interchangeable with the existing breaker. Available in -pole only. Refer to Pages - through -0 for further information.. For additional information, contact Avery Creek, NC Technical Resource Center, Original Cutler-Hammer Panelboard Replacement Chart Table -. Original Cutler-Hammer Panelboard Replacement Chart Cutler-Hammer Panelboard Type Original Branch Circuit New breakers which are a direct physical and electrical replacement for out-of-production breakers. Available in -pole only. See Pages - through -0 for further information. Connectors not available. Not rated for 0% rated breakers. Replacement Solutions New Panelboard Type New CHP CH PRLa CH CHB CHB PRLa CHB NPLAB P PRLa NLAB QL PRLa NAB E EA PRLa PRLa NHB EH PRLa NDP E EA PRLa PRLa Panelboard Replacement HNDP EH PRLa NFB EB EHB CDP EHC EC CA FB HFB FC FH FS HFC H E EA EH EB EHB F FA HF HFA FB HFB CA DA JA KA HKA HK HKL LA HLA LAB LM HLM MA HMA NB HNB H PRLa or PRLB CA H H PRLB B CA DK KDB KD HKD B MDL MDL ND ND RHF RHFA RHF RHFA RHK RHKL RHLM RHLM CA000E

5 March 00 Aftermarket Solutions, Ref. No. [] Replacement Chart - Original Cutler-Hammer Panelboard Replacement Chart (Continued) Table -. Original Cutler-Hammer Panelboard Replacement Chart (Continued) Cutler-Hammer Panelboard Type Original Branch Circuit MP0 H EB EHB EC EHC FB HFB FC HFC FH FS JA JB JS JH JL KA HKA KB HKB KS-D KH-D DA LA HLA HLA LAB LB LBB HLB LC LS (A) LH (A) MA HMA MC HMC MS MH NB HNB NC HNC NS NH MP0 M0 Fusible Switch PH CH CHB H EB EHB EC FC FS FH PB CH CHB See also Page -. See also Page -. Connectors not available. Replacement Solutions New Panelboard Type PRLB PRLF PRLa PRLa New B B H H KDB JB HJD HJD JDC KD HKD JD JD KD KD DK B KD KDB KD H MDL MDL MDL MDL MDL MDL ND ND ND ND ND ND M0 Fusible Switch CH CHB H H CH CHB Plug-in Power and Switchboards Table -. Plug-in Power and Switchboards Cutler-Hammer Panelboard Type EE EP Original Branch Circuit FS FH FL JS JH JL KS KH LS LS(A) LS(E) LH(B) LH(A) LL(E) LS(B) LH(E) MS NS MH H FS FH FL JS JH JL KS KH LS LS(A) LS(E) LH(B) LH(A) LL(E) LS(B) LH(E) MS NS MH NH H Not rated for 0% rated breakers. See also Page -. See also Page -. Replacement Solutions New Panelboard Type PRLP PRLP New H HDC JD HJD JDC KD HKD H H C H MDL ND H C JD HJD JDC KD HKD H H C H MDL ND HND 0 CA000E

6 - March 00 Replacement Chart Aftermarket Solutions, Ref. No. [] 0 Original Westinghouse Panelboard Replacement Chart Table -. Original Westinghouse Panelboard Replacement Chart Westinghouse Panelboard Type Not rated for 0% rated breakers. Available in -pole only. See Pages - through -0 for further information. Connectors not available. See also Page -. Only breakers of the same frame size can be installed across from each other (i.e., in the same horizontal plane). For other configurations contact the Aftermarket Center in Sumter, SC (see Page -). KD breakers can be mounted across from LB breakers if a TAD line side adapter is utilized. All hardware works with this configuration. See also Page -. Existing Branch Circuit Manufactured Between and ABH AB BB BB-LX BB-LXX BB CDP/HCDP CDP/HCDP E E BA BA BA HBA E, EA, EH, F, FA EB, EHB,, FB, HFB, B,, H, C FB-P TRI-PAC JB, KB, HKB, JDB, JD, HJD, JDC CA, CAH, HCA DA, LB, LBB, HLB JA, KA, HKA, DK, KD, HKD, KDC LA, LAB, HLA (00 Amperes) LA-P TRI-PAC LA, LC, HLA (00 Amperes) MA, HMA, MC, HMC LCL NB, HNB, NC, HNC NB-P TRI-PAC Replacement Solutions New Panelboard Type PRLa PRLa PRLa PRLaLX PRLaLX PRLa PRLB PRLB New BAB BAB BAB, B,, H, C FB-P TRI-PAC JDB, JD, HJD, JDC ED, EDH, EDC DK, KD, HKD, KDC, H LA-P TRI-PAC, H, C MDL LCL ND, HND NB-P TRI-PAC Panelboard Replacement HBAW, HBAX, RHF, RHFA Contact your local Eaton Field Sales office. P Fusible Switches PRLF Fusible Switches HP HB NAB NAB NDP NEB NHDP NHEB NHB NLAB NLAB-LX NLAB-AB NLAB-ABH NPLAB NPLAPQ NQC NQB NQP QP QP QB QP WB WP WB WP WCA WEB WEHB WFB WGB WGHB HQP BA E E E, EA, EAH EA EH EH, FA E- QC QC QC QC QP QP QC BA QP QP QPH QBH HP BA HQP QBH QPH CA EB EHB FB GB GHB PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLaLX PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa PRLa HQP BAB HQP HQP BAB HQP HQP QPHW QBHW QHPW BAB HQP QBHW QPHW CA EB, EHB, FB, B GB GHB, RHFA CA000E

7 March 00 Aftermarket Solutions, Ref. No. [] Replacement Chart - Original Westinghouse Panelboard Replacement Chart (Continued) Table -. Original Westinghouse Panelboard Replacement Chart (Continued) Westinghouse Panelboard Type Original Branch Circuit Replacement Solutions New Panelboard Type New Manufactured After PRL BAB, QBHW HQP, QPHW PRLa BAB, QBHW PRL GB, GHB, GHBS PRLa GB, GHB, GHBS-D PRL BAB, QBH GB, GHB, GHBS,, B, H, C ED, EDH, EDC CA, HCA, CAH PRLa BAB, QBHW GB, GHB, GHBS-D,, B, H, C ED, EDH, EDC CA, HCA, CAH PRLB,, B, H, C ED, EDH, EDC CA, CAH, HCA FCL, FB-P, B/LFB JD, JDB, HJD, JDC DK, KDB, KD, HKD, KDC LCL LA-P TRI-PAC LC, HLC, LA, HLA, H, C, MD, MDS, ND, HND, NDC MC, HMC, MA, HMA NC, HNC, NB, HNB NB-P TRI-PAC BAB, QBGF, QBHW, QBHGF, GB, GHB PRLB See also Page -. See also Page -. See also Page -. See also Page -. See also Page A, 00 A, 00 A, 00 A, P connectors are NOT compatible with PW switches.,, B, H, C ED, EDH, EDC CA, CAH, HCA FCL, FB-P, B/LFB JD, JDB, HJD, JDC DK, KDB, KD, HKD, KDC LCL LA-P TRI-PAC LC, HLC, LA, HLA, H, C, MDL, ND, HND, NDC MC, HMC, MA, HMA NC, HNC, NB, HNB NB-P TRI-PAC BAB, QBGF, QBHW, QBHGF, GB, GHB Panelboard Replacement PRLF Fusible Switches PRLF Fusible Switches 0 CA000E

8 - March 00 CDP Aftermarket Solutions, Ref. No. [] 0 (Continued) CDP Originally a Westinghouse Product Westinghouse CDP The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing CDP panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breaker needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). X X X X X X X X X X X X X X X X X " Wide Box 0" Wide Box Figure -. CDP Panel Layout When only one EB, EHB or HFB single-pole breaker is required in conjunction with other frame size breakers, the single-pole breaker space required changes from X to X. Must use -pole connector kit. -/" Solid Neutral Bar A 00 A 00 A 00 A 00, 00 A Thru-Feed Lugs A 0 00 A 00, 00 A 0 -Pole EB EHB, HFB -Pole EB EHB, FB -Pole EB EHB, FB - and -Pole HFB -Pole CA, CAH -Pole CA, CAH Total No. of Poles 0" Wide Box - or -Pole - or -Pole " " JB, KB, HKB JB, KB, HKB - or -Pole - or -Pole DA DA " LBB, LB LBB, LB " HLB HLB - or -Pole - or -Pole " LC, HLC LC, HLC " LA LA - or -Pole MC, HMC " LCL " NC, HNC A Main Lug 0 00 A Section 00 A 00, 00, 00 A -/" -Pole EB EHB, HFB -Pole EB EHB, FB -Pole EHB, FB - and -Pole HFB -Pole CA, CAH -Pole CA, CAH " Wide Box One X space = -/ inches. Blank fillers are required for unused X space. CA000E

9 March 00 Aftermarket Solutions, Ref. No. [] P - (Continued) P Originally a Westinghouse Product -/" X X X X X X X Top Gutter A Solid 00 A Neutral 00 A Bar 00 A 00, 00 A 0 A 0 A 0 A 0 A 0 A 0 A 0 A Main or Branch 00 A (Horizontal Mounted) Side Gutters Tables F and G P, P P 0 Vac P 0 Vdc P, P P 0 V or 00 Vac P 0 Vdc Westinghouse P The panel layouts shown on this and the following pages will aid in determining the space available for the addition of fusible switches into your existing P panelboards. Determine the amount of space available in the panelboard for adding fusible switches. -/ inches of panel height = one X space. Determine the type of fusible switch needed for the required ampere rating and number of poles. 00 Amperes Maximum : Fusible Switches Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). X X X X X X X X X -/" Figure -. P Panel Layout Side Gutters Tables B and C 0 A 0 A 0 A 0 A 0 A 0 A Main or Branch 00 or 00 A (Horizontal Mounted) Main or Branch 00 or 00 A (Horizontal Mounted) Main or Branch 00 or 00 A (Vertical Mounted) A Main Lug 0 00 A Section 00 A 00, 00, 00 A Bottom Gutter P, P 00 Vac P, P P 0 or 00 Vac P 0 Vdc One X space = -/ inches. Blank fillers are required for unused X space..0" Vertical Bus Bar.0"." TYP. 0 MTG. Rails.0" Figure -. P and CDP Bus Dimensions CA000E

10 - March 00 PB/PH/PH-L Aftermarket Solutions, Ref. No. [] (Continued) PB/PH/PH-L Originally a Cutler-Hammer Product or inches wide Cutler-Hammer PB PB 00 Amperes Maximum PH 00 Amperes Main Lug Only or 00 Amperes Main PH-L Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). or inches wide Cutler-Hammer PH inches wide Cutler-Hammer PH-L 0 CA000E

11 March 00 Aftermarket Solutions, Ref. No. [] MP0 - (Continued) MP0 Originally a Cutler-Hammer Product Cutler-Hammer MP0 The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing MP0 panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breakers needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). CA000E 0X X X X X X X X X X Figure -. MP0 Panel Layout If the panelboard has a main breaker, no neutral, no split bus, or no sub-feed or feed-through lugs, add X to provide space for a nameplate. s of the same frame size, regardless of poles, may be mounted opposite of each other. Only Type NC and HNC breakers require a.-inch deep box. Standard box depth is.0 inches. When 00 ampere lug mains are for ()-00 kcmil maximum copper cables per phase, the X unit space can be reduced to X. " Side Gutters " Wide Top Gutter.0" through 00 A.0" A None 00 A 00 A P EB EHB, HFB P EC EHC, FC P EC, EMC, FC, P or P HFB P H P, H, P or P JB, KB, HKB P or P DA, LBB, LB, HLB Neutral Nameplate P EB EHB, HFB P EC EHC, FC P EC, EMC, FC, P or P HFB " Side Gutters -/" This space is -/" P or P not usable LA, HLA, when C.B. to LC, HLC left is used as a main " Wide 0" Wide, 00 A 00, 00 A 00 A P or P MC, HMC P or P NC, HNC Main Lugs Bottom Gutter.0" up through 00 A.0" A " Wide 0" Wide " Wide 0

12 - March 00 EE Aftermarket Solutions, Ref. No. [0] 0 (Continued) EE Originally a Cutler-Hammer Product Cutler-Hammer EE Panelboard The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers and fusible switches into your existing EE panelboards. Determine the amount of space available in the panelboard for adding replacement devices. -/ inches of panel height = one X space. Determine the type of replacement device needed for the required ampere rating and number of poles. 00 Amperes Maximum : s and Fusible Switches Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). " Neutral No X Space (May Be At Bottom) Figure -. EE Panelboard Panel Layout Main device must be mounted at neutral end of double-bus panel. May be used in 0-inch wide single bus interiors. " " " Gutter " " X X X X 0X X 00 A Lug Unit 00 A Branch Switch (00 V With R Fusing) 0X 00 A Main Switch 00 A Branch Switch 00 A Branch Lug Unit 00 A Branch Lug Unit X MS, MH Main NS, NH Main LS, LH X Switch 0 V 00 V T-Fuse Only X 0 A Branch Switch, H, FS, FH, JS, JH, JL KS, KH X MS, MH Main " Gutter LS, LH 00 A Branch Lug Unit 0 A, 0 A Branch Switch, H, FS, FH, JS, JH, JL KS, KH X X X X X X X " CA000E

13 March 00 Aftermarket Solutions, Ref. No. [] EP - (Continued) EP Originally a Cutler-Hammer Product " " " Neutral No X Space Top or Bottom " X X X X -Pole FS, FH, FL,, H, -Pole FS, FH, FL,, H,,, H -Pole -Poles FS, FH,, -Pole -Poles FS, FH,, Poles JS, JH, JL Filler Plate -Pole FS, FH, FL,, H, -Pole FS, FH, FL,, H,,, H -Pole X 00 A MS, MH, MC Main,, H -Pole Blank Wireway - Pole LSB, LHB, LLB, LC X X X X Cutler-Hammer EP Panelboard The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing EP panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breaker needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). X 00 A MS, MH, MC, HMC Branch X 00 A NS, NH, NC, HNC Branch or Main " " " Figure -. EP Panelboard Panel Layout Blank wireway fillers are required opposite any dual breaker unit or adapter. May be used in 0-inch wide single bus interiors. Main device must be mounted at neutral end of double-bus panel. " 0 CA000E

14 - March 00 PRL and PRL, PRLa and PRLa Aftermarket Solutions, Ref. No. [] 0 (Continued) PRL and PRL Originally a Westinghouse Product PRL with Trim 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device bus connectors mounting hardware. For further information, contact your local Eaton Field Sales office or call the Eaton Satellite plant in Atlanta, GA. Refer to Page -. PRLa and PRLa Current Product PRLa 00 Amperes Maximum s Refer to renewal parts data RP00000E for a complete list of available parts including branch device bus connectors and mounting hardware. Renewal parts are available from your Eaton Satellite plant. Refer to Page -. CA000E

15 March 00 Aftermarket Solutions, Ref. No. [] PRL - (Continued) PRL Originally a Westinghouse Product CA000E Westinghouse PRL The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing PRL panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breaker needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Contact the Aftermarket Center in Sumter, SC (see Page -). No Neutral Neutral Section Sub Chassis 00 Amp Maximum Bus Rating -Pole -Pole -Pole -Pole - and -Pole Main Section Main Lug Section -Pole -Pole -Pole Horizontal Mounting Vertically Mounted Figure -. PRL Panel Layout If panel contains only BAB or QBH branch breakers, use a PRL panelboard. BAB and QBH breakers with shunt trips require one additional pole space, i.e.; -pole is -pole size, -pole is -pole size, and -pole is -pole size. GB, GHB breakers cannot be mixed on same subchassis as BAB, QBH. If panel contains only GB or GHB branch breakers, use a PRL panelboard. Not recommended for motor loads. Use JD circuit breaker. Horizontally mounted through 0 ampere main breakers, B,, H and C will be furnished as branch breaker construction. Branch breakers, or poles as required, may be located opposite these main breakers. FBP and LAP top mounting only. 0% rated breaker. LCL main breaker requires -/-inch deep box. X 0 00 A X 0, A X 00, 00 A Poles X- - X- X-0 X- X- X X B H C BAB QBH GB GHB (0 A Max.) CA, CAH, HCA ( A Max.) X 0, A X 00, 00 A P (0 A Max.) (0 A Max.) ( A Max.) (0 A Max.) X (0 A Max.) X B,, H, C (0 A Max.) X CA, CAH ( A Max.) X FCL, FB-P (0 A Max.) X JD, JDB, HJD, JDC (0 A Max.) X DK, KD, KDB, HKD, KDC (00 A Max.) X LC, HLC, LA (00 A Max.) X LCL, LA-P (0 A Max.) C 0

16 - March 00 PRLa Aftermarket Solutions, Ref. No. [] (Continued) PRLa Current Product Main Lugs.0".0" X X X X X X 0 A Std # /0 0 A Oversized # 0 kcmil 0 A Subfeed () # /0 0 A Std # 0 kcmil 0 A Oversized /0 00 kcmil 0 A Subfeed () # 0 kcmil 00 A Std () / kcmil X X 00 A Std () / A Oversized () /0 0 kcmil Neutral P.00"." P () P () P." () P () P." () P () P () P P () P () P () P () P P X X X X X X X Same Cable Size as MLO ED, EDH, EDC A Max. Note: Line Side May Be Either Left or Right. Distance From Load Side of To Box Will Always Be. in. 0 A Max., H, C, B 0 A Max. 0 PRLa The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing PRLa panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breaker needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Retrofit kits and renewal parts are available from your Eaton Satellite plant. Refer to Page -. P P Split Bus.0" Meter Loop.0" ASCO 0 (Split Bus) QUICKLAG BAB.0".0" GHB."." GHB Twin.0" Subfeed.0" Single Subfeed Through Feed Lugs Figure -. PRLa Panel Layout X X X X X X 0X X X Same Cable Size as MLO Bus Connected Cable Connected (Wireout) Ckt. Ckt. Ckt. Ckt. A Max. 0 A Max., QBHGF 0 A Max. or GB, GHB 0 A Max. Note: May Have Multiple Sections Per Panel, Max. Ckts. Per Section. JD, JDB, HJD, JDC, 0 A Max. Size Per Main Layout Size Per MLO Size Chart Not Available With Subfeed ASCO 0 (0 A A) Lug Size Chart. CA000E

17 March 00 Aftermarket Solutions, Ref. No. [] PRLB - (Continued) PRLB Current Product (Originally a Westinghouse Product) CA000E PRLB The panel layouts shown on this and the following pages will aid in determining the space available for the addition of molded case circuit breakers into your existing PRLB panelboards. Determine the amount of space available in the panelboard for adding circuit breakers. -/ inches of panel height = one X space. Determine the type of breaker needed for the required ampere rating and number of poles. 00 Amperes Maximum : s Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Retrofit kits and renewal parts are available from your Eaton Satellite plant. Refer to Page -. " Wide Box " Wide Box " Wide Box Filler Sub Panel 00 A Maximum Bus Rating P P P P Figure -. PRLB Panel Layout Maximum amperes connected to any one connector cannot exceed 0 amperes. GB, GHB breakers cannot be mixed on the same subchassis as BAB, QBHW. When only one single-pole breaker of the group is required on either side of chassis, the single-pole breaker space required changes from X to X. P P P or P or P or P or P or P or P or P or P Load P P P or P or P or P or P " Wide Box One X space = -/ inches. Blank fillers are required for unused X space. " Wide Box " Wide Box X Poles X 0X X X X X 0 X EH To Fusible Transition, All Widths BAB QBGF QBH QBHGF GB GHB 0 A Max. H, C 0 A Max. A Max. CA, CAH, HCA A Max. JD, JDB, HJD, JDC 0 A Max. DK, KD, KDB HKD, KDC LC, L, HLC, HL, LCY,, B, H, C, LA 00 A Max. FCL, FB-P 0 A Max. 00 A Max. JD, JDB, HJD, JDC 0 A Max. LCL, LA-P MC, M, HMC, HM, MCY, MA NC, HNC, NB, NCY DK, KD, KDB, HKD, KDC 00 A Max. NB-P 00 A Max. 00 A Max. 00 A Max. 0

18 - March 00 PRLF Aftermarket Solutions, Ref. No. [] (Continued) PRLF Current Product (Originally a Westinghouse Product) Fusible To T 0 A 0 A 0 A 0 A X X X 0 A 0 V Max. 0 A 0 V Max. X " Wide Box 0 A 00 A Main or Branch Switch " Wide Box X 0 A 00 Vac 0 A 00 Vac X 00 A or 00 A Branch Switch X PRLF The panel layouts shown on this and the following pages will aid in determining the space available for the addition of fusible switches into your existing PRLF panelboards. Determine the amount of space available in the panelboard for adding fusible switches. -/ inches of panel height = one X space. Determine the type of fusible switch needed for the required ampere rating and number of poles. 00 Amperes Maximum " Wide Box Figure -. PRLF Panel Layout 00 A or 00 A Main or Branch Switch 00 A or 00 A Branch Switch " Wide Box X 0 : Fusible Switches Refer to renewal parts data RP00000E for a complete list of available parts including branch device retrofit kits which include the device, as well as, the bus connectors and the required mounting hardware. Retrofit kits and renewal parts are available from your Eaton Satellite plant. Refer to Page -. CA000E

19 March 00 Aftermarket Solutions, Ref. No. [] Technology Upgrades Clipper Power System Visor Series Clipper Power System Visor Transient Voltage Surge Suppressor The Cutler-Hammer Clipper Power System is a hybrid Transient Voltage Surge Suppressor (TVSS) used to protect sensitive electronic equipment from the damaging effects of voltage transients and electrical line noise. The Visor s design combines both suppression and filtering elements to provide best-in-class performance. Field installation is required. Benefits Visor can be externally mounted to existing distribution equipment. Surge ratings: 0, 0, 0, 00, 0, 00, 00 and 00 ka. Standard NEMA /R enclosure, optional NEMA X and. Surface or flush mounting. Full range of diagnostic and monitoring options. Remote mountable display panel. For more information about Clipper Power Systems, contact your local Eaton Field Sales office. CA000E Clipper Power System Visor Series and Pow-R-Command Lighting Control Pow-R-Command Cutler-Hammer Pow-R-Command is a family of microprocessor-based lighting control systems designed for today s modern facilities. They may be utilized as a stand-alone, or networked for the control of lighting and other branch circuits. System Features Include: Day/Date/Time of Day scheduling. Holiday scheduling up to 0 days/year. Astronomical time scheduling. Real-time clock. Hardware diagnostics. Off warning by blinking lights. Manual load override control. Brownout and power failure recovery. Telephone override of schedules. Switch override of schedules. Remote access to system. Dimming systems for fluorescent fixtures. Priority load management. Pow-R-Command Lighting Control Existing facilities can be retrofitted to include various Pow-R-Command scenarios allowing customers varying degrees of control. For more information on upgrading your building to include the energy savings and control of Pow-R-Command, contact your local Eaton Field Sales office. - 0

20 -0 March 00 Panelboard Retrofits Aftermarket Solutions, Ref. No. [] Panelboard Retrofits Pow-R-Line R Renovation Panel The Pow-R-Line R Retrofit Panelboard is designed specifically for use in the renovation of existing electrical systems. This innovative solution employs a chassis design that enables the use of the existing back box, conduit and cables. An exclusive depth-adjusting mechanism and an integrated trim assembly provides for fast, trouble-free mounting of the new panelboard interior into any existing enclosure. The panelboard chassis is designed for the use of main lugs or a main breaker and can accommodate, 0 or branch circuits. 0 Type PRLa Another Custom-Assembled Panelboard Capability from Your Local Eaton Satellite Save time and money when upgrading and expanding existing electrical services by utilizing existing panelboard enclosures and conduit runs. Retrofitting existing panelboards can be an effective solution for: Providing additional circuits for load growth. Replacing obsolete equipment. Upgrading protective device interrupting ratings. Accommodating system change and additions. Adding ground fault circuit interrupters. Adding lighting controls. Adding transient voltage surge protection. The unique capabilities of the Eaton Satellite plants can provide special configurations to meet the special needs encountered in retrofit applications. Pow-R-Line R renovation panelboards or custom built panelboard interiors and trims can be provided to retrofit most any manufacturer s existing panelboard enclosure. Armed with the necessary information about the existing installation and the needed upgrade, the professional staff at your local Satellite plant can offer the assistance and application support to assure an accurate quotation and on-time delivery of a quality retrofit product. Renovation Panel Product Description 0 Vac maximum. Single-phase -wire or single-phase -wire. -phase -wire or -phase -wire. amperes maximum. 0 ampere maximum branch breakers. Fits existing box depths from.0 to.00 inches (. to. mm) deep. Integrally mounted neutral assembly. Ground bar and bonding conductor included. Neutral and ground convertible from left-right. Bolt-on branch breakers. Factory assembled. Application Description Lighting and appliance branch panelboards. Fully rated or series rated. Interrupting capacities to 0 ka symmetrical. Suitable for use as Service Entrance Equipment where specified on the order. Standards and Certifications UL. Federal Specification W-P-c. CSA C. No.. Pow-R-Line R Retrofit Chassis Chassis Features Designed to accommodate minimal box widths at.00 inches (. mm). Innovative telescoping chassis accommodates depths from.0 to.00 inches (. to. mm) without the need for box modifications. Universal mounting locations allow the neutral and grounds to be relocated from top to bottom or left to right side of back plate. High quality laser cut trim with lock. Trim and door mount directly to the chassis assembly. Concealed trim hardware is not dependent on back box for mounting. Refer to publication CA00E for complete information. CA000E

21 March 00 Aftermarket Solutions, Ref. No. [] Satellite Locations - Product Support Services Figure -. Satellite Locations Further Information Publication Number RP00000E RP00000E RP00000E RP00000E Seattle 0 th Street SW Suite Auburn, WA 00 () -0 Fax () -0 San Francisco 0 Cabot Boulevard Hayward, CA () - Fax () -0 Los Angeles 0 Philadelphia Street Mira Loma, CA () - Fax () - Description Pricing Information Phoenix South Park Lane Suite Tempe, AZ (0) - Fax (0) - The Eaton satellite concept is unique to the industry and remains the only manufacturer to provide this service. Eaton manufactures and delivers standard and custom assembled panelboards and switchboards within days. A phone call is all that is necessary for immediate order entry. Renewal Parts Data for MP0 and MP-00 Renewal Parts Data for PB, PH, PH-L, EP and EE Renewal Parts Data for CDP/HCDP, P, PRL-LX, PRL, PRL and PRL Renewal Parts Data for PRLa, PRLa, PRLa, PRLB, PRLF and PRLP Price List for MP0 and MP-00 PL00000E Price List for PB, PH, PH-L, EP and EE PL00000E Price List for CDP/HCDP, P, PRL-LX, PRL, PRL and PRL PL00000E Price List for PRLa, PRLa, PRLa, PRLB, PRLF and PRLP PL00000E Discount Symbol CE Cutler-Hammer is a federally registered trademark of Eaton Corporation. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. UL is a registered trademark of Underwriters Laboratories Inc. Chicago AEC Drive Wood Dale, IL 0 (0) 0-00 Fax (0) 0- Denver 0 Airport Boulevard Unit C, Dock Aurora, CO 00 (0) -00 Fax (0) - Baltimore Santa Barbara Road Elkridge, MD () - Fax () - Cleveland Venture Drive Unit B Parma, OH 0 () -0 Fax () -0 St. Louis Gravois Road St. Louis, MO () - Fax () - Dallas Westport Parkway Suite 0 Grapevine, TX 0 () - Fax () - Houston West Little York Suite 0 Houston, TX 0 () -0 Fax () - Main manufacturing plant New Jersey Stemmers Lane Westampton, NJ 000 (0) -0 Fax (0) - Hartford Day Hill Road Windsor, CT 00 (0) -0 Fax (0) - Raleigh S. Miami Blvd., Suite Durham, NC 0 () -0 Fax () - Sumter (0) - Atlanta 000 Highlands Parkway SE Suite Smyrna, GA 00 () 0-0 Fax (0) - Orlando St. Valentine Way Orlando, FL (0) - Fax (0) - 0 CA000E

22 - March 00 Aftermarket Solutions, Ref. No. [0] 0 This page intentionally left blank. CA000E

Vintage Westinghouse panelboards

Vintage Westinghouse panelboards Supersedes February 9 PRL1-LX PRL1 / PRL2 PRL CDP, HCDP FDP Contents Description Page Procedure for identifying renewal parts................................................... 2 Distributor ordering instructions.........................................................

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Panelboards. Panelboards Contents

Panelboards. Panelboards Contents -1 February 7 Contents Description Page EZ Box and EZ Trim.............................................. -2 Product Selection............................................... -4 Product Description.............................................

More information

EOEM panelboard and switchboard (OPS) Program

EOEM panelboard and switchboard (OPS) Program Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit

More information

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards Panelboards Solar Applications.7 Contents Description Introduction.............................. Product Selection Guide.................. EZ Box and EZ Trim........................ Type PRL1a...........................

More information

Panelboards and Lighting Controls

Panelboards and Lighting Controls Product Guide and Lighting Controls Assembled Unassembled and Lighting Controls and Lighting Control Contents 1.1 Introduction Product Selection... 1-2 1.1 EZ Box and EZ Trim Product Description... 1-4

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards Molded Case Selection Guide Replacement s for Eaton Panelboards Molded Case Selection Guide Product Range in Stock and Ready to Go Range KAIC @ 240Vac KAIC @ 277Vac KAIC @ 347Vac KAIC @ 600Vac Terminals

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/12/2011 Reference

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits.

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits. Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

PROJECT MANAGEMENT Transmittal No 17D

PROJECT MANAGEMENT Transmittal No 17D GH Phipps Construction Co. 5995 Greenwood Plaza Blvd. Suite 00 Greenwood Village CO 80-470 PROJECT MANAGEMENT Transmittal No 7D5780-00 PROJECT: Thistle-Valmont Square Interior & Exterior Renovation DATE:

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard... .6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone

More information

Vintage Cutler-Hammer Panelboards and Switchboards

Vintage Cutler-Hammer Panelboards and Switchboards Vintage Cutler-Hammer Panelboards and Switchboards Price List PL01400003E Effective January 2008 Supersedes PL01400003E Pages 1 8, Dated February 2004 TABLE 1. CATALOG NUMBERS AND PRICING CATALOG/ STYLE

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Pow-R-Line panelboards

Pow-R-Line panelboards Price List PL01400001E Supersedes January 2008 Pow-R-Line panelboards Table 1. Catalog numbers and pricing Trim lock 1A32258H03 234.00 PRL1a connector kit 1C96608G01 412.00 1C96608G03 532.00 1C96608G05

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

Transfer switch OT III open or delayed transition, non-automatic

Transfer switch OT III open or delayed transition, non-automatic Specification sheet Transfer switch OT III open or delayed transition, non-automatic 40 1000 amp Description The Cummins OTIII non-automatic transfer switch offers flexibility when remote controlled or

More information

Panelboard Renewal Parts Supplement

Panelboard Renewal Parts Supplement Panelboard Renewal Parts Supplement Contents Page Page Contents Page PRL 1a and a Neutral Assemblies..................................................... 3 PRL 1a and a Ground Assemblies.......................................................

More information

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB Panelboards and Lighting Control Metering Service Sections.7 Metering Service Section Contents Description Metering Service Sections Page Catalog Number Selection........................ 482 Product Selection..............................

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

X1PB: Explosionproof Panelboards

X1PB: Explosionproof Panelboards X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Low Voltage Busway Features, Benefits and Functions Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

Current Eaton panelboards

Current Eaton panelboards Renewal Parts RP01400001E Supersedes February 2009 Current Eaton panelboards PRL1a PRL1a-LX PRL2a PRL2a-LX PRL3a PRL4B PRL4F PRL5P Pow-R-Command Contents Description Page Description Page Procedure for

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

CONTRACTOR/CM: DISTRIBUTION PANELBOARDS

CONTRACTOR/CM: DISTRIBUTION PANELBOARDS SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES SUBMITTAL NUMBER: 647-0.00 SUBMITTAL DETAILS: SUBJECT: CONTRACTOR/CM: DISTRIBUTION PANELBOARDS : WILLIAMS COMPANY : BRAD KUBIN 30 SILVER STAR RD. ORLANDO, FL,

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Integrated Equipment Ratings

Integrated Equipment Ratings 14th Edition Integrated Equipment Ratings ka X X Z Z X @t 1 Z = 0 A =,000 @t 2 Z > 0 A

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

Typical Specification Page 4. Introduction Page 5. Description Page 5. Circuit Breakers Page 5. Fuses Page 5. Circuit Protection and Continuity Page 5

Typical Specification Page 4. Introduction Page 5. Description Page 5. Circuit Breakers Page 5. Fuses Page 5. Circuit Protection and Continuity Page 5 Index Typical Specification Page 4 Introduction Page 5 Description Page 5 Circuit Breakers Page 5 Fuses Page 5 Circuit Protection and Continuity Page 5 Overcurrent Analysis - Fully Rated Page 6 Overcurrent

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

PRODUCT LINE SHEET. Honesty. Integrity. Honor

PRODUCT LINE SHEET. Honesty. Integrity. Honor PRODUCT LINE SHEET Honesty. Integrity. Honor WHO WE ARE At HB, we are dedicated to serving the Electrical Community through the distribution of electrical supplies. We strive to offer the best customer

More information

and legacy Motor Control Center Aftermarket Renewal Parts Catalog

and legacy Motor Control Center Aftermarket Renewal Parts Catalog tiastar TM and legacy Motor Control Center Aftermarket Renewal Parts Catalog Game Changing Innovation www.usa.siemens.com/mcc Answers for industry. Table of Contents Ordering Processes 1-2 Section Parts

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin A19 (painted steel) Or Hoffman Bulletin A19S (stainless steel) Wall Mounted Disconnect Enclosures Rev.

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

Westinghouse Electric Corporation Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A.

Westinghouse Electric Corporation Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A. February 1991 Supersedes, pages 3-4, dated February 1988 Mailed to: E, D, C/29-500A Type SM Safety Mechanism The Westinghouse Type SM safety handle mechanism is designed to prevent tampering by unauthorized

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

www. ElectricalPartManuals. com Low Voltage Distribution Switchboards and Power Assemblies

www. ElectricalPartManuals. com Low Voltage Distribution Switchboards and Power Assemblies 8 December, 174 Supersedes 31-526, pages 1-2, dated March, 173. Mailed to: E, D/12, 6/DB Access View Westinghouse Electric Corporation Distribution Equipment Division St. Louis, Mo. 631 Front View 31-526

More information

Stock as of Diversified Ventures (416)

Stock as of Diversified Ventures (416) product_code part_no description onhand_qty CUT 10-1308-3 Culter Overload Block 6 CUT 10-1308-5 Culter Overload Block 1 CUT 10250T113 Cutler 30.5mm Green Extended PB Head 1 CUT 10250T1311N Eaton 2-Position

More information

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

LCP Coordination Panel Operations & Maintenance Manual Table of Contents LCP Coordination Panel Operations & Maintenance Manual Table of Contents Overview... NEC Requirements for Selective Coordination... LCP Datasheet... CCMR Series POWR-PRO Fuses - Datasheet... JTD Series

More information

CIRCUIT BREAKER PANELBOARDS

CIRCUIT BREAKER PANELBOARDS CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E 100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................

More information

MOLDED CASE CIRCUIT BREAKERS

MOLDED CASE CIRCUIT BREAKERS EB -, -, -Poles; Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 EHB -, -, -Poles; 4 Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 -Pole, 77 Volts AC, 5 Volts DC➊ Underwriters Laboratories,

More information

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin CWY (painted steel) Or Hoffman Bulletin CWSD (stainless steel) CONCEPT Wall Mounted Disconnect Enclosures

More information

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Motor Control Centers

Motor Control Centers 2100.1 2100 and FlashGard Product Overview........................................ Product....................................... Application..................................... Features, Benefits and

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features 11 Panelboards Features Another innovation from Siemens is the P3 panel. It is a smaller, footprint distribution panel to fit a large number of applications that require more (or larger) branch devices

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards type P Lighting and Power Distribution Panelboards Specifications Main Breaker: 400A Maximum Main Lugs only: 400A Maximum Voltages: 480Y/277V AC Maximum 250V DC Maximum 3Ø3W, 3Ø4W, Ø3W, Ø2W General P panelboards

More information

Order No. of the options EMC filter Class A

Order No. of the options EMC filter Class A Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Quick selector reference guide. Motor Control Center Aftermarket Buckets Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

OPERATOR ADAPTER A21WHAMTA

OPERATOR ADAPTER A21WHAMTA OPERATOR ADAPTER A21WHAMTA Installation Instructions for Westinghouse Type AMT Below Handle Mechanisms for Disconnect Switches And Circuit Breakers, and Flex Shaft Handle Mechanisms for Circuit Breakers

More information

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

WITH ALL THE STYLES AND FEATURES OFFERED FROM OFFICES TO GO, IT S EASY FOR THE BUDGET MINDED BUSINESS TO SELECT HIGH QUALITY WORKPLACE FURNITURE

WITH ALL THE STYLES AND FEATURES OFFERED FROM OFFICES TO GO, IT S EASY FOR THE BUDGET MINDED BUSINESS TO SELECT HIGH QUALITY WORKPLACE FURNITURE WITH ALL THE STYLES AND FEATURES OFFERED FROM OFFICES TO GO, IT S EASY FOR THE BUDGET MINDED BUSINESS TO SELECT HIGH QUALITY WORKPLACE FURNITURE AT THE RIGHT PRICE. OTG2913 - Shown in White Luxhide (BL28)

More information

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6 Revision D Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6 Size 2 Size 3 Fig. 1 Type W Standalone Overload Relays Size 5 THE OVERLOAD RELAYS Advantage Type W three phase,

More information