Series 14 Installation Instructions

Size: px
Start display at page:

Download "Series 14 Installation Instructions"

Transcription

1 and field service checklist Series Installation Instructions Table of Contents Page Page Page & 5 Page 6 Page 7 Page System Components Amplifiers (A0 shown) Introduction and Dimensions Specifications Installation of Components Field Service Checklist Preliminary Circuit Analysis Low Fire Start Time Adjustment Sensitivity Adjustment Wiring Diagrams Temperature Calibration Adjustments A0 (all temperature ranges) A0U (replaces A0L, suitable replacement for A0)(all temperature ranges - includes 0 or 0 second low fire start capability) Amplifier-Selectors (with integral temperature dial) (A0U Amplifier / AD0U Amplifier-Selector shown) AD0U (replaces AD0 and AD0L)(all temperature ranges - includes 0 or 0 second low fire start capability) Dual Temperature Amplifier-Selectors: (AD shown) Remote Temperature Selectors: AD (integral dual selector - any comb. of standard ranges avail.) Example - ADBC (0 to 70 F and 60 to 0 F, use w/tsbc Example - ADAD (0 to 0 F and 00 to 50 F, use w/tsad TD (55 to 90 F w/override 0 to 0 over set point) TDA (0 to 0 F) TDA- (0 to 0 F w/ override 0 to 0 F over set point) TDB (0 to 70 F) TDC (60 to 0 F) TDD (00 to 50 F) TDE (00 to 50 F) TDF (0 to 0 F w/override 0 to 0 over set point) TDG (90 to 0 F) TD- (55 to 90 F w/0 to 70 F override) * use w/ts TD- (55 to 90 F w/two outputs) TDG- (90 to 0 F w/two outputs) NOTE: Remote Selector and Discharge Temperature Sensor must have same temperature range to be compatible. Optional: ETD- enclosure, EFP- cover plate only - no enclosure Discharge Air Temperature Sensors: use with TS (55 to 90 F) TSA (0 to 0 F) TSB (0 to 70 F) TSC (60 to 0 F) TSD (00 to 50 F) TSE (00 to 50 F) TSF (0 to 0 F) TSG (90 to 0 F) TSJ (0 to 60 F) To be used w/ AD0-6 TS (dual sensor - any combination of standard ranges available) Example - TSG (55 to 90 F and 90 to 0 F, use w/td & TDG, or TDG [selector w/switch], or ADG) Example - TSAD (0 to 0 F and 00 to 50 F, use w/tda & TDD, or TDAD [selector w/ switch], or ADAD) s: (and sensor) s: MT-9 or -9 (9 length) MT- or - ( length) MT- or - ( length) MT- or - ( length) MT-57 (57 length) M (/ & / pipe size) M5 (/ & / pipe size) M6 (/ & pipe size) MRD (, -/, -/ pipe size) MRE (-/ & pipe size) MRG (-/ & pipe size) MRJ ( flanged) MR-D, E, G, J (used for -speed blower or dual fuel operation) NOTE: M (Modulator) valve requires a pressure regulator for high fire setting. MR (Modulator-Regulator) valve requires no pressure regulator up to 5 psi. OPTIONAL SYSTEM COMPONENTS: Dual Temperature Selector: DOOR HEATERS -TDHD use w/ts (door closed 55 to 90 F/open 90 to 0 F) PAINT SPRAY BOOTHS OR OTHER DUAL APPLICATIONS- TD (dual selector w/switch - any comb. of standard ranges avail.) Example - TDG (55 to 90 F [spray] and 90 to 0 F [dry], use w/tsg Example - TDAD (0 to 0 F and 00 to 50 F, use w/tsad TD X (same as TD, less enclosure) Inlet Air Temperature Sensors: use with TS0765A (: ratio) TS0765B (5: ratio) TS0765C (.5: ratio) Override Stat: (use only with TD, F,-, A-) T5 (0 to 90 F) 00 Maxitrol Company, All Rights Reserved

2 Introduction and Dimensions System Options Selectra SERIES electronic gas flame modulation systems are designed primarily for make-up air heating, as components of direct fired equipment. They may be field installed on existing equipment or specified for new equipment installation. Natural, manufactured, mixed, LP and LP gas air mixture are compatible gases. The systems utilize Modulator or Modulator-Regulator valves. Amplifiers are available with low-fire start, and with integral or remote temperature selection. A discharge air temperature sensor is mounted within a mixing tube housing. Option - a room override thermostat provides space temperature control by raising the discharge air temperature to a pre-selected point - when used in conjunction with the remote temperature selector. Option - an inlet air sensor (and mixing tube) provides inverse change in discharge air for each degree change in inlet air - when installed in a convenient duct location upstream of the burner. Option - a dual temperature selector replaces TD to provide dual control for door heaters, or other applications such as paint spray booths (TD_ or _X, or AD_). A0U, AD0U Mounting Holes 6.00 (5.).00 (50.) (5.9).69 (.9).50 (.).00 (76.) (AD models have integrated temperature dial) TD.5 T Maxitrol Company, All Rights Reserved

3 A0 ETD REF..50 Mounting Hole -Places.6 DECREASE INCREASE SENSITIVITY.5 /6.50 REF. DO NOT.5 TAMPER..0 /6 MIXING TUBES. (7.6) REF. Mounting Hole -Places LENGTH SEE PAGE ) / REF..00 DIA. /6 9 /6 #0-6 X / LG. BINDING HD. SHEET METAL SCREW (-REQ D.) #0- X / LG. BINDING HD. SH METAL SCR (-REQ D.) AD.5.7)..6 (66.5). (7.9) 5.75 (.).0 00 Maxitrol Company, All Rights Reserved

4 Specifications Power Requirements: VAC, 50/60 Hz Class II transformer NOTE: Transformer secondary must not be grounded in any portion of the circuit external to a Maxitrol amplifier. If existing transformer is grounded, a separate isolated transformer must be used. Electrical interference may effect performance and/or damage equipment. Ambient Limits: Operating o to 5 o F / -0 o to 5 o C Non-operating o to 5 o F / -6 o to 5 o C Gases: Suitable for application in natural, manufactured, mixed gases, liquefied petroleum gases and LP Gas Air Mixture piping systems. Vent: M, 5, 6...vertical vent outlet / NPT - A06 installed. MR...two vents located in upper housing, both equipped with vent limiting means Pressure Limits: Maximum Discharge Pressure: (M, 5, 6)... 7 w.c. / 7 mbar Static Pressure Rating: (M, 5, 6) psi / 5 mbar Maximum Operating Inlet Pressure: M, 5, 6... psi / 70 mbar MR psi / 5 mbar Maximum Emergency Exposure*: M, 5, psi / 0 mbar MR....5 psi / 6 mbar * May not function properly at this pressure, but will suffer no internal damage Installation of Components Control wires connected to the Override Stat, Discharge Air Sensor, or Remote Temperature Selector must not be run close to or inside conduit with power or ignition wires. Doing so may cause the unit to function erratically or may destroy the amplifier. If shielded wires are used, shield must be insulated and grounded at the amplifier location only. Wiring Run: If control wiring is inside conduit with line voltage wiring, use shielded cable up to 00 ft. For best results up to 00 ft., run control wiring in separate conduit. For longer runs see Remote Selector below. Amplifier / Amplifier-Selector: contains the wiring terminals and sensitivity adjustment - install in any convenient location that is protected from the weather and contaminated atmosphere. Typical Gas Trains Remote (or Dual) Selector: Install in control cabinet or other chosen location. NOTE: Suffix letters must match, e.g. TSA must be used with TDA. For wiring runs longer than 00 ft. substitute ES6-/ES6- for TD. The ES6s are a -piece version of the TD. ES6- is a temperature setting dial only, ES6- must be mounted at furnace location. Discharge Temperature Sensor / Assembly: sensor housed in mixing tube, install in discharge air stream. Optional: Dual Temperature Selector: see preceding Remote/Dual selector. Room Override Stat: mount in heated area not in direct path of discharge air stream. Inlet Air Sensor: install in convenient location upstream of burner, in intake air duct. Modulator (M) or Modulator-Regulator (MR) : Mount in upright position in horizontal run of pipe, downstream of other controls - a separate gas pressure regulator must be used with any modulator (M) valve. MR : Modulatorregulator valve M : Regulator upstream of modulator valve 00 Maxitrol Company, All Rights Reserved

5 Field Service Checklist SYMPTOm POSSIBLE CAUSE FIELD TEST REMEDY A. No gas flow.. Modulating valve improperly installed (or see Symptom L ).. Arrow on side of should point in direction of gas flow.. Install properly. B. Continuous Low Fire (electronics problem).. Short circuit or no voltage to the amplifier.. Open circuit in TD. Remote Temperature Selector circuit or wiring.. Short circuit in TS, Discharge Air Sensor circuit or wiring. 5. Faulty amplifier.. Check for VAC at amplifier terminals 7 and.. Inspect for loose or broken wires between amplifier terminals and, and TD terminals and, and TD terminals and.. Connect test resistor as described in Preliminary Circuit Analysis. Follow procedure outlined. 5. Check items, and.. Prove the power source.. Tighten connections or replace wiring.. If modulating voltages are obtained, Check TS circuit for shorts. Replace TS if necessary. 5. If items,, and check out and modulating voltages are still not obtained, amplifier may be assumed faulty. Replace. C. Continuous Low Fire (electronics 6. Short circuit or open circuit in Modulator Coil. 7. Plunger missing, jammed or improperly installed. 6. Measure resistance across modulator terminals with connecting wires detached. 7. Inspect. Plunger should be installed per diagrams page and operate freely in solenoid sleeve. 6. Replace modulator head if not approximately 5-55 ohms for M6 and 60-0 ohms for MR. 7. Clean or replace plunger if necessary. Install as per diagrams page. D. Correct Minimum Fire Erratic or Pulsating Flame.. Incorrect by-pass metering valve adjustment. 9. Excessive negative burner pressure.. See valve adjustments on page. 9. Close main gas supply and measure manifold pressure with blower operating. Reading should be less than.5 w.c. negative pressure.. Adjust to proper minimum fire. 9. If reading is greater than.5 negative pressure, check for clogged filters or other inlet air restrictions. Consult factory for other solutions. E. Continuous High Fire (electronics problem). 0. Short circuit in TD Remote Temperature Selector circuit or wiring.. Open circuit in TS/TS0765. Discharge or Inlet Air Sensor Circuit or wiring.. Jumper not connected across amplifier terminals and. (A0 only) 0. Inspect for shorts at or between Amplifier terminals and or TD terminals and.. Check TS/TS0765 for open internal circuit. Connect test resistor as described in Preliminary Circuit Analysis. Follow procedure outlined.. Inspect. 0. Correct wiring if shorts exist.. If modulating voltages are obtained, check TS/TS0765 for open circuits. Replace TS/TS Correct the wiring. F. Continuous High Fire (electronics. Foreign object holding valve open.. Plunger jammed.. Remove bottom plate and inspect valve and seat.. Inspect. Plunger should be smooth, clean, and operate freely in solenoid sleeve.. Clean seat. Clean valve or replace if necessary.. Clean, or if necessary, replace plunger. G. Incorrect Maximum Fire. 5. Inlet pressure too low. 6. Incorrect outlet pressure adjustment of Pressure Regulator. 5. Read pressure at inlet to modulating valve using a manometer with unit operating at full fire. Pressure should be equal to the sum of outlet pressure setting plus pressure drop of he valve (see Maxitrol Capacity Chart). 6. Read manifold pressure using manometer and compare with recommendation of equipment manufacturer. 5. Increase inlet pressure if possible. 6. See valve adjustments on page. H. Erratic or Pulsating Flame. 7. Hunting.. Erratic air patterns or improper TS location. 9. Wiring is run next to high voltage switching circuits causing induced voltages. 0. Faulty Amplifier or erratic voltage supply. 7. Adjust sensitivity control counter-clockwise.. Connect test resistor as described in Preliminary Circuit Analysis. Turn TD selector dial so heater goes through its entire modulating range. 9. Temporarily wire each of TD, TS, and MR externally and observe heater/ equipment operation. 0. With test resistor connected (per Item #) and TD locally connected (per item#9), turn TD selector dial through entire modulating range. Observe D.C. voltage across modulator terminals. 7. If flame stabilizes, adjust sensitivity control to maintain an even flame.. If the flame is steady throughout the entire modulating range, the TS must be moved. 9. If smooth operation results, isolate effected wiring from source of induced voltage. 0. If erratic or unstable D.C. voltages are obtained throughout the modulating range, the amplifier may be assumed faulty. Replace. If erratic operation is noted only over a small range of or volts, the voltage source may contain surges. Consult Maxitrol. I. Incorrect Discharge Air Temperature.. Inlet Air Sensor is used.. Incorrect Wiring.. System out of calibration.. Improper TS location. 5. Room Override Thermostat circuit closed.. Inlet Air Sensor changes 0 for each.5 0, 5 0, or 0 outside temperature change from 60 0 (predetermined turndown varies with model used).. Check wiring diagrams page 7.. Sensed temperature (thermometer next to TS) does not correspond to TD setting.. Sensed temperature (thermometer next to TS) does not represent average discharge air temperature. 5. Remove Override Thermostat lead from terminal of TD.. Sensed temperature will vary from TD dial settings. This is intentional.. Correct wiring.. See calibration procedure.. Move TS to location where average representative temperature can be sensed. 5. TD dial setting, then check thermostat setting and/or check wiring for shorts. J. Burned out Transformer. 6. Short circuit in modulator coil. 7. Short circuit between amplifier and modulator valve. 6. Measure resistance across modulator terminals with red lead wires disconnected. 7. Inspect wiring. 6. Replace modulator head if less than 0 ohms. 7. Correct wiring is short is found. K. Discharge Air Temperature too Low when T5 is operative.. Too low an Override Temperature setting. 9. Burner capacity may be insufficient.. Check Override Temperature Selector of TD. 9. Check for high fire (Maximum manifold pressure specified for heater).. Reset to correct temperature. 9. If on high fire, control can do no more. Heater unable to furnish additional heat to raise temperature. 00 Maxitrol Company, All Rights Reserved 5

6 Preliminary Circuit Analysis For ease in troubleshooting, it is advisable to wire the system as follows (this differs from the normal connection). The Discharge Air Sensor is disconnected and replaced with a 0,000 ohm, / watt test resistor (terminals and ). If inlet air sensor is being used, disconnect and replace with a jumper. On units where the Remote Temperature Selector is located a considerable distance from the heater, it may be advantageous to connect the selector at the heater location. Connect a DC volt meter (capable of reading 0- V DC) on the Modulator or Modulator-Regulator terminals. Set the temperature to the minimum dial setting. The DC voltage should read 0 volts. The DC voltage should gradually increase to at least 0 volts as you slowly rotate the dial to the maximum dial setting. If these voltages are obtained, the valve function can now be checked out. The operation of the valve with regard to voltage is as follows: from 0 volts to approximately 5 volts, the modulating valve should be on bypass flow with the heater operating on low or minimum fire. From approximately 5 volts to 5 volts DC, the valve should be performing its modulating function, and the heater should be firing at a modulated flow rate between low and high fire, depending upon the voltage. Above approximately 5 volts DC, the valve should be delivering full flow to the heater and the unit should be on full fire. If the DC voltage is obtained on the valve terminals, but the heater does not respond as described, the problem can be isolated to the valve itself or to the gas control manifold of the heater (see check list, pages and 5). In the event proper voltages are obtained, and the valve responds correctly to these DC voltages, the problem could well be in the wiring leading to the Discharge Air Sensor or the Discharge Air Sensor itself. This should be also reviewed in the check list. A0U & AD0U Low Fire Start Time Adjustment The low fire start duration can be set to approximately 0, 0 or 0 seconds, and begins timing after the amplifier has been energized. The time is set by placing the jumper over the appropriate jumper block pins. NOTE: When low fire start is desired the jumper must be removed from the J6 jumper block and placed on the J5 jumper block. The M/MR valve remains in the low fire setting position during the low fire start time period. J6 J5 J5 A0U and AD0U model amplifier-selector (cover removed) (AD0U Shown) 0 second low-fire start jumper block 0 Second 0 Second 0 Second Sensitivity adjustment If the proper voltages are not obtained when wired as instructed, the problem can be isolated to the electronics and this may once again be reviewed in the check list. After the troubleshooting test, remove the test resistor and reconnect the Discharge Air Sensor to terminals and. If Remote Temperature Selector has been moved return it to its original position. Sensitivity Adjustment The sensitivity control will allow the user to control the response of the system. Caution should be exercised in the use of this adjustment. Under normal usage the pointer should be located on the mark on the label (A0). A0 model amplifier If hunting is encountered (rapid oscillation), rotating the sensitivity adjustment (R on A0U, AD0U) counter-clockwise will dampen the oscillation - stabilizing the flame. DO NOT adjust unless necessary, because decreasing the sensitivity will increase the temperature DROOP of the system DECREASE SENSITIVITY INCREASE R J6 TIMER 0 SEC 0 SEC J5 0 or 0 second low-fire start jumper block Discharge Air Temp Set DO NOT TAMPER Sensitivity adjustment 00 Maxitrol Company, All Rights Reserved 6

7 Wiring Diagrams A0 model amplifiers AD model amplifiers WITH OPTIONAL ROOM OVERRIDE STAT TS0766 & TD Selector TS& tube t5 override TD Selector TS& tube TRANSFORMER low-fire switch TS & VAC 0va Low fire switch (not supplied by maxitrol) A # # WITH OPTIONAL INLET AIR SENSOR a0 A0U model amplifiers Transformer A0U TS & TD Selector T5 Override TS & TS0766 & TD Selector WITH OPTIONAL ROOM OVERRIDE STAT WITH OPTIONAL INLET AIR SENSOR AD0LU model amplifier-selectors AD0U TS & TS & TS0766 & Transformer WITH OPTIONAL INLET AIR SENSOR 00 Maxitrol Company, All Rights Reserved 7

8 Temperature Calibration NOTE: The components of this system are individually calibrated and are not part of a matched set. It is necessary to place an accurate temperature measuring device as near the Discharge Air Sensor as possible. Set the Remote Temperature Selector at least 0 degrees above outside air temperatures. Adjustments (See bulletin MT05 for additional M/MR valve information) NOTE: Low fire adjustment should be checked whenever the high fire adjustment is changed. MR VALVE High Fire Manifold Adjustments:. Disconnect wires from amplifier terminal # (see page 7). This cause the valve to call for continuous high fire.. Remove seal cap (A), and turn regulator pressure adjusting screw to obtain desired manifold pressure. (Clockwise rotation increases pressure.). Reconnect the wires to amplifier terminal #. NOTE: If low fire bypass is on maximum, the desired high fire outlet pressure may not be achieved. Low Fire or Bypass Adjustments:. Disconnect wire from amplifier terminal #, this causes valve to call for continuous low fire.. Remove cap (B), and loosen lock screw (C). Turn (D) to desired low fire adjustment. (Clockwise rotation reduces minimum flow rate.). Tighten set screw (C), replace cap (B) and reconnect wire to amplifier terminal #. M, 5, 6 VALVE High Fire Manifold Adjustments:. Disconnect wires from amplifier terminal # (see page 7), this causes the valve to call for continuous high fire.. Adjust the pressure regulator to obtain the desired manifold pressure (7 w.c. maximum).. Reconnect the wires to amplifier terminal #. Low Fire or Bypass Adjustments:. Disconnect wire from amplifier terminal #, this causes the valve to call for continuous low fire.. Remove cap (A), and turn adjusting screw (B) to desired low fire adjustment. (Clockwise rotation reduces minimum flow rate.). Replace cap (A), and reconnect wire to amplifier terminal #. modulator B A B D C A Maxitrol Company 555 Telegraph Rd., PO Box 0 Southfield, MI 07-0 SEL_MI_EN_ Maxitrol Company All Rights Reserved

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list BULLETIN MI2046-1/04 REPLACED MI1078 SERIES 14 INSTALLATION INSTRUCTIONS and field service check list A1014 Amplifier A1014L1 Amplifier / AD1014/AD1014L1 Amplifier-Selectors AD1214 Amplifier Mixing Tube

More information

Series 14R. Installation Instructions and Field Service Checklist

Series 14R. Installation Instructions and Field Service Checklist Series 14R Installation Instructions and Field Service Checklist Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property damage, personal injury,

More information

Series 44 Installation Instructions

Series 44 Installation Instructions and field service checklist Series 44 Installation Instructions Table of Contents Page 1 Page 2 & 3 Page 4 Page 5 Page 6 Page 7 Page 8 System Components Amplifiers System Components Introduction and Dimensions

More information

Introduction. System Components

Introduction. System Components The Selectra SERIES 94 is for use with either direct or indirect gas fired units (furnaces, ovens, etc.). The system may be field installed on existing equipment or specified for new equipment installation.

More information

Series 20 Installation Instructions

Series 20 Installation Instructions Series 20 Installation Instructions Installation Instructions and field service checklist Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list BULLETIN MI046-/98 REPLACED MI078 SERIES 4 INSTALLATION INSTRUCTIONS field service lt A04 Amplier All or Amplier / Amplier-Selects Page Page Page 4 & 5 Page 6 Page 7 Page 8 Table Contents Introduction

More information

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Model No. DFC-X Support 877-351-4702 DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual covers the following products: DFC-X TS-01 DFTD RDU DAT-12 PWM-10V

More information

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR 24 Volt AC input Built in 15 second low fire start timer 0-24 Volt DC modulating output Remote temperature selection Calibration trim pot Rated for -40 F (-40 C) DFC-1 STANDARD TEMPERATURE CONTROL DFC-2

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CATALOG Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

10V. the rack of the oil pump must be on the

10V. the rack of the oil pump must be on the P.E.D 20.. ESG2002 series ELECTRONIC GOVERNOR INSTRUCTION A1000C-W ELECTROMAGNETIC ACTUATOR Before inst al l el ectromag neti c, p lea se inspect that the rack of the oil pump shouldn' t be stuck in any

More information

ESD5500E Series Speed Control Unit

ESD5500E Series Speed Control Unit ESD5500E Series Speed Control Unit 1 SPECIFICATIONS INTRODUCTION PERFORMANCE Isochronous Operation ± 0.25% or better Speed Range / Governor 1-7.5 KHz Continuous Speed Drift with Temperature ±1% Maximum

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

SERIES 20/30 INSTALLATION INSTRUCTIONS and field service check list

SERIES 20/30 INSTALLATION INSTRUCTIONS and field service check list BULLETIN MI2044-/9 REPLACED MI00 SERIES 20/0 INSTALLATION INSTRUCTIONS field service check lt Page 2 Page Page 4 & 5 Page 6 Page 7 Page Table of Contents Specicions Dimensions Installion of Components

More information

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number: INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: APR 125-5 Part Number: 9 1688 00 100 Publication Number: 9 1688 00 990 Revision H: 07/2001 CONTENTS SECTION 1 GENERAL INFORMATION...1-1 DESCRIPTION... 1-1

More information

G76x Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition

More information

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES RATE-OF-FLOW CONTROL RATE-OF-FLOW WITH SOLENOID & EXTERNAL FILTER.2 .3 RATE-OF-FLOW & PRESSURE REDUCIN G WITH SOLENOID & EXTERNAL FI LTER.4 RATE-OF-FLOW & PRESSURE SUSTAINING WITH EXTERNAL FILTER.5 RATE-OF-FLOW

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1988 Toyota Celica 1988 Automatic A/C-Heater Systems Celica * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system, use only approved refrigerant recovery/recycling

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

HVF110, 210, 310, 410HD

HVF110, 210, 310, 410HD 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. HVF110, 210, 310, 410HD

More information

BGD278 Series BASOTROL CE Approved Gas Valve

BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin Issue Date November 16, 2012 BGD278 Series BASOTROL CE Approved Gas Valve The BGD278 Series gas valve is a combination main and pilot valve intended for use in conjunction with solid-state

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide IntelliFire Plus Ignition System *For authorized gas technicians use only. 9/15/2011 Hearth & Home Technologies Page1 Guide Table of Contents Introduction. 3 Tools and Instruments...

More information

TC62D Installation Instructions

TC62D Installation Instructions TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port.

More information

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

X4 Installation and Operation Manual - POWER FLAME INCORPORATED 7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice

More information

G600 Series Replacement Intermittent Pilot Ignition Controls

G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation DODGE ENGINEERING & CONTROLS, INC. 196 Riverneck Road Chelmsford, MA 01824 PHONE (978) 244-1200 FAX (978) 244-1422 TOLL FREE (877) 334-2875 RE Generation II Troubleshooting Guide Section I Preliminary

More information

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide C802/C802D/C802TD/C820 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

WEBER CARBURETOR TROUBLESHOOTING GUIDE

WEBER CARBURETOR TROUBLESHOOTING GUIDE This guide is to help pinpoint problems by diagnosing engine symptoms associated with specific vehicle operating conditions. The chart will guide you step by step to help correct these problems. For successful

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CATALOG Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions

More information

RP-4000 Reserve Power Control

RP-4000 Reserve Power Control Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification

More information

INDIRECT FIRED FURNACE PARTS

INDIRECT FIRED FURNACE PARTS INDIRECT FIRED FURNACE PARTS 986964 Power Venter (Combustion Blower) Assembly ** S **Includes: Fan, Motor, Housing, etc. (Fasco) 986365 Igniter S 986725 Flame Sensor S 986982 H.S.I. Module 50E47-XXX w/

More information

INSTALLATION DATA 712 Series Pilot

INSTALLATION DATA 712 Series Pilot INSTALLATION DATA 712 Series Pilot Ignition Systems (FLAME RECTIFICATION) LOCKOUT MODEL 712-005 712-006 712-008 712-009 NON-LOCKOUT MODELS 712-005 712-016 712-017 712-019 712-022 CSA DESIGN CERTIFIED TO

More information

G861 Series Integrated Function. Direct Spark Ignition Control

G861 Series Integrated Function. Direct Spark Ignition Control Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:

More information

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Troubleshooting SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION WILL NOT RUN RUNS BUT WON'T SPRAY LOW SPRAY AT NOZZLE UNEVEN SPRAY PATTERN WILL NOT PRODUCE HOT WATER Pump switch in OFF position Place switch

More information

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide ICM325HN Head Pressure Control with Optional Heat Pump Override Temperature sensitive control regulates head pressure Installation, Operation & Application Guide For more information on our complete range

More information

ENGINE GOVERNING SYSTEMS

ENGINE GOVERNING SYSTEMS ENGINE GOVERNING SYSTEMS ESD5400 Series Speed Control Unit INSTALLATION The speed control unit is rugged enough to be placed in a control cabinet or engine mounted enclosure with other dedicated control

More information

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09 INTRODUCTION This instruction manual provides information about the operation and installation

More information

Fan Powered Low Profile Variable Volume Terminal Units

Fan Powered Low Profile Variable Volume Terminal Units MANUAL INSTALLATION Fan Powered Low Profile Variable Volume Terminal Units FEVLP / FPVLP / FDVLP Series v001 Issue Date: 07/19/16 07/19/16 Price Industries Limited. All rights reserved. TABLE OF CONTENTS

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

DENISON HYDRAULICS Jupiter 500 Driver Card Series S Back to Content DENISON HYDRAULICS Jupiter 500 Driver Card Series S20-11712-0 Publ. 9-AM681 E-Mail: denison@denisonhydraulics.com Internet: http://www.denisonhydraulics.com SYSTEM FEATURES SYSTEM FEATURES

More information

Y99AB-4 BASO Test Kit

Y99AB-4 BASO Test Kit Application Note Y99AB-4 Issue Date August, 8 Y99AB-4 BASO Test Kit 3 3 7 4 5 DC TCN-4 Nut 31543-3 Terminal Nut JOHNSON CONTROLS, INC WATERTOWN, WI., U.S.A 473-4 Nut Figure 1: Y99AB-4 Test Kit 64119-1D

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual The IAQ50 Air Damper/Monitor Installation and Maintenance Manual RUSKIN MANUFACTURING 3900 Dr. Greaves Road Kansas City, Missouri 64030-1183 U.S.A. ! WARNING DO NOT TAMPER WITH (REMOVE, REPLACE, RELOCATE

More information

CATALOG. 2 nd Edition

CATALOG. 2 nd Edition CTLOG 2 nd Edition Service and installation must be performed by a trained/experienced service technician. ll products used with combustible gas must be installed and used strictly in accordance with

More information

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

G821L/G822L Series Integrated Function Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G821L/G822L Issue Date 1199 G821L/G822L Series Integrated Function Direct Spark Ignition Controls

More information

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting PAGE 1 This document outlines questions to ask and components to check during TES troubleshooting. More detailed troubleshooting procedures are available in the TES Troubleshooting Guide. 1. Flow Light

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1993 Toyota Celica 1993 Automatic A/C-Heater Systems Celica SPECIFICATIONS SPECIFICATIONS TABLE Application Specification Compressor Type 1.6L... Nippondenso 10PA15C 10-Cyl.

More information

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide 8/28/00 TROUBLESHOOTER S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinator Check water flow through Flow Controller

More information

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE 100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up

More information

INSTALLATION/OPERATING INSTRUCTIONS TSC

INSTALLATION/OPERATING INSTRUCTIONS TSC INSTALLATION/OPERATING INSTRUCTIONS TSC Two-Stage Set Point Control with External Activation Two-Stage Heating (Rotation Included) Two-Stage Cooling (Rotation Included) Change-Over Control (Heat/Cool)

More information

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Technical Instructions Document No. 155-313P25 EA 599-15 EA1157R1 Description The Powermite 599 MT SSC61U and SSC61.5U

More information

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &

More information

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE 24RRG 36RRG 48RRG 60RRG ML-135339-00024 ML-135340-00036 ML-135341-00048 ML-135342-00060 24RRG Shown - NOTICE - This Manual is prepared for the use of trained

More information

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS FUEL SYSTEM Section 3A Fuel Delivery System Table of Contents Specifications............................. 3A-1 WMC Carburetor Specifications............. 3A-2 WMC Carburetor Specifications.............

More information

BLOWER VACUUM SWITCH FAILED OPEN

BLOWER VACUUM SWITCH FAILED OPEN F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check

More information

(For serial numbers before w/ analog control)

(For serial numbers before w/ analog control) SEQUENCE OF OPERATIONS (For serial numbers before 2038616 w/ analog control) MODEL 1154-000-EA NAT. GAS 230 VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230 VAC 50 HZ. 1 PHASE POWER SUPPLY Electrical power

More information

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:TRQSMAN16 Table of Contents Contents Table of Contents... 2

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

E Series CE Approved Intermittent Pilot Ignition Control

E Series CE Approved Intermittent Pilot Ignition Control Installation Instructions Issue Date January 11, 2013 E Series CE Approved Intermittent Pilot Ignition Control Application The E Series CE Approved Intermittent Pilot Ignition Control is a safety control

More information

Hayward error codes and troubleshooting

Hayward error codes and troubleshooting http://waterheatertimer.org/intermatic-trippers-and-parts.html#pool 50 Hayward error codes and troubleshooting Section V. TROUBLESHOOTING http://www.hayward-pool.com/prd/in-ground-pool-manuals_10201_10551_14502_-1

More information

INSTRUCTION MANUAL FOR

INSTRUCTION MANUAL FOR INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: SR32A Part Number: 9 0750 00 104 Publication Number: 9 0750 00 990 Date: January, 1979 Revision G: March, 1997 SECTION 1 GENERAL INFORMATION 1-1. INTRODUCTION

More information

SECTION Climate Control System - General Information

SECTION Climate Control System - General Information 412-00-i Climate Control System - General Information 412-00-i SECTION 412-00 Climate Control System - General Information CONTENTS PAGE DIAGNOSIS AND TESTING Climate Control System... 412-00-2 Inspection

More information

MODEL 1100 TURBINE FLOW METER

MODEL 1100 TURBINE FLOW METER MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering

More information

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL INTRODUCTION The PM300 voltage regulator is an encapsulated electronic voltage regulator that controls the output of a brushless AC generator by regulating the

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1433-000-E, 1434-000-E, 1456, 1457 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804

More information

TROUBLESHOOTING FLOW CHARTS

TROUBLESHOOTING FLOW CHARTS TROUBLESHOOTING FLOW CHARTS Bowl Style Carburetor Troubleshooting Hunts and Surges Will Run only on Prime Will run only if the choke is used Determine that the governor system is functioning properly

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

EG1069X. Generator Electronic Governor Controller Operation Manual

EG1069X. Generator Electronic Governor Controller Operation Manual EG1069X Generator Electronic Governor Controller Operation Manual Smoke Limit Controller Compatible with Barber Colman Dyn1-1069X series *Use for reference purpose only and not a genuine Barber Colman

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 40401-c (-sp) Electronic Fuel Pump Operating and Installation Instructions This Product is Patent Pending. Application available upon request CAUTION! This product is to be installed only

More information

Service Bulletin. (This bulletin and all other active bulletins are downloadable from our website at

Service Bulletin. (This bulletin and all other active bulletins are downloadable from our website at Bulletin 00--ABDE Service Bulletin (This bulletin and all other active bulletins are downloadable from our website at www.frymaster.com/parts_service.) Bulletin 00--ABDE Page of + Worksheets Date: 0//00

More information

N-1001 Economizer Logic Network

N-1001 Economizer Logic Network 24-7074- 6, Rev. A N-1001 Economizer Logic Network Product Bulletin N-1001 Issue Date 0316 Features Choice of O.A. Dry Bulb Economizer, Differential Temperature Economizer, or Enthalpy Economizer cycles

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL 1. GENERAL This chapter contains information on the storage, distribution, and indicating components of the fuel system. The engine is supplied with fuel drawn out of the left or right integral fuel tank

More information

WALKIE HIGH LIFT HYDRAULIC SYSTEM

WALKIE HIGH LIFT HYDRAULIC SYSTEM WALKIE HIGH LIFT HYDRAULIC SYSTEM W30-40ZA [B453]; W20-30ZR [B455]; W25-30-40ZC [B454] PART NO. 1524251 2000 SRM 1025 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Easytork Solenoid Valve IOM

Easytork Solenoid Valve IOM Easytork Solenoid Valve IOM General This installation document is to be read in conjunction with the Easytork Vane Actuator IOM. Description The Easytork Solenoid Valve ( ESV ) series is intended for the

More information

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED 1. ENCLOSURE REQUIRED If the OC1 control is furnished as an open-chassis unit (standard), mount control in an enclosure 12 x 10 x 5 or larger and mount enclosure where room temperature does not exceed

More information

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction

More information

INSTALLATION/OPERATING INSTRUCTIONS MCP

INSTALLATION/OPERATING INSTRUCTIONS MCP INSTALLATION/OPERATING INSTRUCTIONS MCP Modulating Digital Set Point Control with Boiler Output and External Activation Temperature Range -30 to 250 F (-35 to 120 C) Pressure Ranges 0-30, 0-100, 0-200PSI

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

Oxygen Probe Troubleshooting Guide Marathon Monitors, Inc.

Oxygen Probe Troubleshooting Guide Marathon Monitors, Inc. Oxygen Probe Troubleshooting Guide 2010 Marathon Monitors, Inc. NOTE All of the following tests assume that the oxygen sensor is operating above 1100 F and the process that is being read is stable. Sensor

More information

Installation and Operation Instructions

Installation and Operation Instructions Peerless Pump Company PJPC Jockey Pump Controllers Installation and Operation Instructions Peerless Pump Company 2005 Dr. M. L. King Jr. Street Indianapolis, IN 46202 Bulletin 4857341 Rev. December 21,

More information

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127) ESD5100 Series Speed Control Unit 1 INTRODUCTI The ESD5100 Series speed control unit is an all electronic device designed to control engine speed with fast and precise response to transient load changes.

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current

More information

DIAGNOSIS AND TESTING

DIAGNOSIS AND TESTING 412-00-1 Climate Control System - General Information 412-00-1 DIAGNOSIS AND TESTING Climate Control System Refer to Wiring Diagrams Cell 54, Air Conditioner/Heater for schematic and connector information.

More information

Deep Well Pump Control Valve

Deep Well Pump Control Valve MODEL 61-02 661-02 Deep Well Pump Control Valve Prevent Surges in Pipelines Simple Hydraulic Operation Adjustable Opening & Closing Speeds Solenoid Control Can Be Operated Manually Proven Reliable Design

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVEN MODEL 1100-000-A SERIES (SN 2038615 & BELOW) SERVICE MANUAL Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information