Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

Size: px
Start display at page:

Download "Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement"

Transcription

1 Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144 Data Sheet Analogue Meters with Moving - Iron Movement Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / I / 117

2 Analogue Meters With Moving - Iron Movement - DE Movement Moving iron movement has pivots of very high hardness.movement is suspended between spring loaded saphire jewels. Movement is critically damped by use of silicon oil Application The moving iron, panel meters,de 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages in the usual frequency range of Hz. Moving iron meters indicate rms-values practically independent of waveform even of high harmonic. Error of indication may occur for extreme waveforms (e.g. phase gating controls) & for frequencies above 1kHz. waveforms ( e.g. phase gating controls) and for frequencies above 1kHz. These meters offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). For CT operated ammeters, dials can be fitted based on CT ratio. Front window glass and bezel can be easily replaced. Applicable Standards Nominal case and cutout dimensions for IS 2419 indicating Electrical instruments DIN 437 Scale and pointer for electrical measuring IS 1248 instruments DIN 4382 Connections and Terminal markings for IS 1248 panel meters DIN 4387 Terminal bolts / leads. DIN 462/46282 Safety requirements and protecti ve IS measures for Electrical indicating. DIN 45/8-7, instruments and their accessories. VDE 11/ VDE 41/ 1-76 IEC 529, IEC 11 Performance specifications for direct IS 1248 acting indicating analogue electrical IEC51/DINEN651 measuring instruments and their accessories DIN 4371 Environmental conditions IS 1248 IS 9, Part 5, 7, 8, VDE / VDI 354 Front frames for indicating measuring DIN instruments Principle dimensions UL Combustibility Class UL 94 V- Comply with following European directives Scale and Pointer Pointer Pointer deflection Scale characteristics Scale division Scale length over range Ammeters voltmeters for use on Voltage transformer Scale Interchangeability Knife - edge pointer...9 Near Linear above 1% of nominal full Scale value Coarse - fine De48 De72 DE96 DE mm 61mm 97mm 146 mm 2 times nominal current 1.2 times nominal voltage Interchangeable 89 / 336 / EEC (EMC Directive), 73/23/EEC (low voltage directive) & ammemdment 93/68/eec, for CE Marking Mechanical Data Case details Moulded square case suitable for mounting in Control / Switchgear panels, Machinery consoles. Case material Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Glass Electrical Data Measured quantity Power consumption voltmeters Ammeters < 15A Ammeters > 15A Overload capacity Continuously Short duration Voltmeters AC voltage or current < 4.5VA <.5VA <.8 VA (acc. to IS 1248 / IEC 51) 1.2 times rated voltage /current max 1V,upto max 5 seconds. Ammeters DE 48 DE 72/96/144 5 s max. 1 times(2 A max). 1 times 1 s max -- 4 times(25 A max.) Enclosure code (IEC 529) Insulation class Rated insulation voltage Proof voltage Installation category Insulation resistance Black Vertical Panel fixing Swivel screws Mounting Stackable in a single cutout Panel thickness < 4 mm Terminals Voltmeters and Hexagon studs, M4 screws and ammeters <= 3A wire clamps E3 (DIN 46282) Ammeters > 3A Ammeters > 6A Reference Conditions Accuracy class Reference conditions Ambient temperature Input Waveform Frequency Other conditions Threaded studs M6 with nuts Threaded Studs M8 with Nuts. 2 times rated voltage IP 52 case IP for terminals without back cover IP 2 for terminals with back cover Group A according to VDE 11 DE 48 66V DE72/96/144 1V DE 48 2kV DE72/96/144 3kV 6 V CAT III (IEC 11) > 5 Mohm at 5 V d.c 1.5 according to IS 1248 (IEC 51/ DIN EN 651) 23 C + 2 Nomial position + 1 Rated value of measured quantity sine wave,distortion factor <= 5 % HZ IS 1248 (IEC 51/ DIN EN 651) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / I / 117

3 Analogue Meters With Moving - Iron Movement - DE Nominal Range of Use Ambient Temperature Frequency External magnetic field Environmental Conditions...5 o C o Vertical Hz (Voltage) Hz (current) At.4 ka/m,less than 6 % of fiducialvalue (not as a percentage class index) Climatic suitability Climate category II as per IS 1248 (climatic class 3 according to VDE/VDI 354) Operating temperature C Storage temperature C Relative humidity < 75% annual average, non-condensing Shock resistance Vibration resistance 15g. 11 ms 1.5 g at about 5 Hz Standard Measuring Ranges A. C. Voltage 6V 1V 15V 1mA 15mA 25mA 25 V 4mA 4 V 6mA 6 V 1A 1V 1.5A 12 V 2.5A 132 V 3A 15 V 4A 2 V 5A 25 V 6A 3 V 1A 4V 15A 5 V 2A 6 V 25A 75 V (except DE 48) 3A For use on voltage transformer A. C. Current 4A 5A 6A.../1V secondary 1A (except DE 48) Options Case Antiglare glass Red, Yellow,Blue, White Red index pointer Front adjustable on site o o on request Dial Blank dial Special markings Division dials Colour markings/bands Over range (ammeters) Accessories Safety Terminal Protection Safety Precautions With initial and end values marked. Numbering / Lettering. Basic divisions without numbering. Red or green No over range or 6 times over range over nominal current Full sized polycarbonate back cover to provide protection against accidental contact ( hand and fingers ) acc.to IS 9249, VDE 41. 1) Instruments with damaged bezels or window glasses must be disconnected from the mains. 2) Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing. If non - insulated connector wires are used. 3) The back cover must be snapped into place after connector wires have been clamped for protection against accidental contact. 4) Scales may only be replaced under voltage - free conditions. 5) Bezels and window glasses may only be replaced under voltage - free Conditions..../11 V secondary for use on current transformer.../1a secondary or.../5a secondary Rishabh Instruments Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in 1 / 1 / I / I / 117

4 Analogue Meters With Moving - Iron Movement - DE Connections Ordering Information Type DE Moving-iron panel meter AC Voltage (Direct connected) L1 N(L2) Front dimension Over range (ammeters) Measuring Ranges 48 mm x 48 mm 72 mm x 72 mm 96 mm x 96 mm 144 mm x 144 mm no over range * 3 2 times nominal current * 1, 6 times nominal current Refer to table inside AC Current (Direct connected) L Terminal protection Panel Fixing Red Index Pointer full sized polycarbonate backcover Swivel Screw None * 1 N(L2) Normal glass Antiglare glass AC Current (for use on current Transformer) Black Red,Blue,Yellow,White L1 N(L2) Dimensions For Voltmeters & ammeters upto 3 A k k l L For ammeters > 3 A Dial Logo Vertical On request Standard scale same as measuring range Blank dial with division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green RISHABH standard Please clearly add the desired specifications while ordering Ordering example Dimensions (in mm) DE 48 DE 72 DE 96 DE 144 Bezel a Case b Depth c X d e Cotout Size Depth with X X Back cover f X c=62mm,for I > 3A & up to 6A 64 c = 67 mm, for I > 6 A X f=69.5mm, for I > 6 A X X f=75mm, for DE 48 I > 3 A X X Weight (approx.).1 kg..16 kg..2 kg..4 kg. DE 72 Measuring range 15 V, dial - 1% Specifications are subject to change without notice(2/9) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / I / 117

5 DC Ammeter, Voltmeter - DS DS DS DS DS U Data Sheet Analogue Meters with Moving - coil Movement Rishabh Instruments Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@ridhabh.co.in 1 / 1 / I / II / 117

6 DC Ammeter, Voltmeter - DS Application The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). Front glass, Bezel & Dial can be easily replaced. Movement Moving coil movement has pivots of very high hardness. Movement is suspended between spring loaded saphire jewels. Movement is properly shielded & critically damped by eddy currents induced in coil former. Mechanical Data Case details Moulded square case suitable for mounting in Control / Switchgear panels, Machinery consoles. Case material Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Glass Colour of bazel Black Vertical Panel fixing Swivel screws Mounting Stackable in a single cutout Panel thickness < 4 mm Terminals Voltmeters and ammeters <6A Ammeters >6A Ammeters >6A Electrical Data Hexagon studs, M4 screws and wire clamps E3 (DIN 46282) Threaded studs M6 with nuts Threaded studs M8 with nuts Measured quantity Overload capacity DC voltage or current (acc. to IS 1248 / IEC 51) Continuously Short duration 1.2 times rated voltage /current 2 times rated voltage,5 s Max 1 times rated current,5 s Max Enclosure code IP 52 case (IEC 529) IP for terminals without back cover IP 2 for terminals with back cover Insulation class Group A according to VDE 11 Rated DS 48 DS 72/96/ V 1V Proof volta ge 2kV 3kV Installation catagory 6 V CAT III (IEC 11) Insulation resistance > 5 Mohm at 5 V d.c. *4 Accuracy class 2.5 *5 Not applicable for DS 144 *6 Total lead resistance of.35 ohm is considered for mv ranges while calibration. *7 Not applicable for DS 48 Rishabh Instruments Standard Measuring Ranges D. C. Voltage Rated Value Approx Voltage drop *4 *5 15uA *4 *5 25uA *4 4 ua *4 5 ua *4 6 ua 1 ua 15 ua 25 ua 4 ua 5 ua 6 ua 1 ma 1.5 ma 2.5 ma 4 ma 5 ma 6 ma 1 ma 15 ma 2 ma 25 ma 4 ma 6 ma 1 ma 15 ma 25 ma 4 ma 6 ma 1 A 1.5 A 2. 5 A 4 A 5 A 6 A 1 A 15 A 2 A 25 A 3 A 4 A 6 A *7 1 A For use on transducer 4-2 ma Scale and Pointer 14 mv 24 mv 374 mv 424 mv 6 mv 4 mv 6 mv 14 mv 54 mv 54 mv 54 mv 37 mv 196 mv 196 mv 196 mv 196 mv 196 mv 196 mv 11 mv 72 mv 72 mv Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@ridhabh.co.in Rated Value D. C. Voltage *5 15 mv *5 25 mv 4 mv 5 mv 75 mv 1 mv 15 mv 25 mv 4 mv 6 mv 1 V 1.5 V 2.5 V 4 V 6 V 1 V 15 V 25 V 3 V 4 V 5 V 6 V 1 V 15 V 2 V 25 V 3 V 4 V 5 V 6 V For use on external shunt * 6 * 6 75 mv * 6 15 mv 3.33kohm/V 3.33kohm/V 3.33kohm/V 3.33kohm/V 1 Kohm/V Pointer Knife - edge pointer Pointer deflection...9 Scale characteristics linear Scale division Coarse - fine Scale length DS 48 DS 72 DS 96 DS mm 63 mm 97 mm 146 mm Scale Interchangeability Interchangeable Accuracy at Reference Conditions Sensitivity ( + -1%) Accuracy class 1.5 according to IS 1248 Reference conditions (IEC 51/ DIN EN 651) Ambient temperature 23 C + 2 C Nomial position + 1 Input Rated value of measured quantity Other conditions IS 1248 (IEC 51/ DIN EN 651) Nominal range of use Ambient temperature...5 C Vertical + 5 External magnetic field.5 mt 1 / 1 / I / II / 117

7 DC Ammeter, Voltmeter - DS Environmental Conditions Climatic suitability Climate category II as per IS 1248 (climatic class 3 according to VDE/VDI 354) Operating temperature C Storage temperature C Relative humidity < 75% annual average, non-condensing Shock resistor 15g, 11ms Vibration resistor Hz /.15mm 1.5 g at about 5 Hz. Applicable Standards Nominal case and cutout dimensions for indicating Electrical instruments Scale and pointer for electrical measuring instruments Connections and Terminal markings for panel meters Terminal bolts / leads. Clamp straps for connections Safety requirements and protective measures for Electrical indicating. instruments and their accessories., Options Case Antiglare glass Red, Yellow, Blue, White. Red index pointer Front adjustable on site on request...18 Dial Blank dial With initial and end values marked. Special markings Numbering / Lettering. Division dials Basic divisions without numbering. Colour markings/bands Red or green Rishabh Instruments IS 2419 DIN 437 IS 1248 DIN 4382 IS 1248 DIN 4387 DIN 462/46282 DIN IS 9249 DIN 45/8-7, VDE 11/ VDE 41/ 1-76 IEC 529, IEC 11 Performance specifications for direct acting indicating analogue electrical IS 1248 IEC 51/DIN EN 651 measuring instruments & their accessories DIN 4371 Environmental condition IS 1248 IS 9, Part 5, 7, 8, VDE / VDI 354 Front frames for indicating measuring instruments Principle dimensions DIN UL Combustibility Class UL 94 V- Technical conditions of delivery for electrical instruments Mechanical strength (Free fall test, vibration test) DIN 4371 IS 1248 IS 9 VDE 411, part 1, Sec. 43/44, IEC 11 Comply with following European directives 89 / 336/ EEC (EMC directive),73/23/eec(low voltage directive)& amendment 93/68/EEC, for marking. Others Zero position Increased sensitivity Adjustment of Resistance (Sensitivity) Accessories Safety Terminal protection Full sized polycarbonate back cover to provide protection against accidental contact (hand and fingers) acc.to IS 9249,VDE 41. Connections DC voltage DC current Dimensions Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@ridhabh.co.in L + L - L + L For Voltmeter & Ammeter < 6A For Ammeter 6-1 A Dimensions DS 48 DS 72 DS 96 DS 144 (in mm) Bezel a Case b Depth c* d e Cutout size weight(approx).13kg.18kg.22kg.43kg Depth with back cover f** * c = 68mm, for I= 6 to 6 A * c = 78mm, for I> 6 A ** f = 7mm, for I= 6 to 6 A ** f = 75mm, for DS 48, I >6A Centre zero or off-set zero 4kohm/V for voltmeters 1...6V 1 kohm/v for Voltmeters V Within + 1% at 23 C X 1 / 1 / I / II / 117

8 DC Ammeter, Voltmeter - DS Ordering Information Type DS Moving-coil panel meter Front dimension 48 48mm x 48 mm mm x 72 mm mm x 96 mm mm x 144 mm Measuring ranges refer to table inside Normal glass Antiglare glass Black Red,Blue,Yellow,White Vertical on request...18 Terminal protection Full sized polycarbonate back cover Zero position Centre, Off-set zero Increased sensitivity 4 kohm/v for voltmeters V 1 kohm /V for voltmeters V Adjustment Resistance Within + 1 % at 23 C (Sensitivity) Dial Standard scale same as measuring range, Blank dial with division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green Logo RISHABH, for Indian Sales C.G. * 1, for export through Crompton Greaves. I.D. Others Safety Precautions * Instruments with damaged bezels or window glasses must be disconnected from mains. * Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing, if non-insulated connector wires are used. * The back cover must be snapped into place after the connector wires have been clamped for protection against accidental contact. * Scales should be replaced under Voltage- free conditions. * Bezels and window glasses should be replaced under Voltage - free conditions. Ordering example standard Please clearly add the desired specifications while ordering DS 72 measuring range... 2 ma, dial with...1 C, red mark at 37 C. Specifications are subject to change without notice (2/9) Rishabh Instruments Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@ridhabh.co.in 1 / 1 / I / II / 117

9 Analogue Maximum Demand Ammeters with Bimetallic Movement, Combined Bimetallic and Moving - Iron Ammeter BM 72 BM 96 EB 72 EB 96 Data Sheet Analogue Maximum Demand Ammeters with Bimetallic Movement, Combined Bimetallic and Moving - Iron Ammeter Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / VII / 117

10 Analogue Maximum Demand Ammeters with Bimetallic Movement, Combined Bimetallic and Moving - Iron Ammeter Application The maximum demand ammeters BM/EB 72/96 housed in moulded polycarbonate cases,monitor the most economic use of transformer stations & LT distribution feeders by indicating the thermal/time characteristics of the load. The high torque of the thermal movement drive a red slave pointer linked to the instrument pointer. The slave pointer will remain at the maximum value reached for a subsequent reading until being manually reset by a sealable reset knob to the position of the instrument pointer. Where the instantaneous and maximum demand currents are required, the EB 72/96 instrument,which combines a thermal bimetallic and a moving - iron movement in the same case mounted diagonally opposite to each other. These instruments are suitable for frequency range of 15-4Hz. These meters offer several advantages in Switchboard and Generating Set panels. Number of meters can be mounted in a single Cut out (Mosaic Mounting). The bezel, front window glass and dial can be easily replaced Applicable Standards Nominal case and cutout dimensions for IS 2419 indicating measuring instruments DIN 437 Scale & pointer for electrical measuring IS 1248 instruments DIN 4382 Connections and Terminal markings for IS 1248 panel meters DIN 4387 Terminal bolts / leads. DIN 462/46282 Clamp straps for connections DIN Safety requirements for Electrical IS 9249 indicating instruments and their accessories. DIN 45 / 8-7, VDE 11 / VDE 41 / 1-76 IEC 529, IEC 11 Performance specifications for direct IS 1248 acting indicating analogue electrical IEC51/DINEN651 measuring instruments & their accessories DIN 4371 Environmental conditions IS 1248 IS 9, Part 5, 7, 8, VDE / VDI 354 Front frames for indicating measuring DIN instruments Principle dimensions UL Combustibility Class UL 94 V- Technical conditions of delivery for DIN 4371 electrical instruments Mechanical strength (Free fall test, IS 1248, IEC 51, vibration test) IS 9 VDE 411, Part 1, Sec. 43/44, IEC 11. Comply with following European directives 89 / 336 / EEC (EMC directive), 73/23/EEC (low voltage directive) & amendment 93/68/EEC, For Marking. Scale and Pointer Pointer Pointer deflection Scale characteristics Over range Scale division Scale length Mechanical Data Case details Case material Panel fixing Mounting Panel thickness Terminals Electrical Data Measuring quantity Thermal time delay (blimetalic) Power consumption 1 A rated current 5 A rated current Continuously Short duration Enclosure code (IEC 529) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Knife - edge pointer...9 Bimetallic quadratic moving - iron near linear bimetallic moving - iron 1.2 times rated- 2 times rated- -current -current Coarse - fine EB 72 Bimetallic Moving - iron 52 mm 61 mm BM 72 Bimetallic mm EB 96 Bimetallic Moving - iron 71 mm 97 mm BM 96 Bimetallic mm Moulded square case suitable for mounting in Control/Switchgear panels, Machinery consoles. Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Glass Black Vertical Swivel screws Stackable in a single cutout < 4 mm Hexagon studs, M4 screw and wire clamps E3 Rishabh Instruments 1 / 1 / I / VII / 117 AC currents 15 minutes (8 min / 2 min on request) Response time (moving iron) Approx 1s BM 96 < 1.6 VA < 2.5 VA Overload capacity (acc to IS 1248 / IEC 51) EB 96 < 2.5 VA < 3.4 VA 1.2 times rated current 1 times rated current, 1 sec max. Saturating current transformers shall be used to protect the movement against overload exceeding specified overload rating. IP 4 case IP for terminals without backcover IP 2 for terminals with backcover Insulation class Group A according to VDE 11 Rated insulation voltage 1V Proof voltage testing 3 kv Installation category 3 V CAT III (IEC 11) Insulation resistence > 5 Mohm at 5 V d. c.

11 Analogue Maximum Demand Ammeters with Bimetallic Movement, Combined Bimetallic and Moving - Iron Ammeter Accuracy at Reference Conditions Accuracy class acc to IS 1248/ IEC 51/DIN EN 651 Reference conditions Ambient temperature 23 C + 2 C Input Frequency Nomial position +1 Rated value of current HZ Other conditions As per IS1248 (IEC 51/ DIN EN 651) Options Case Antiglare glass Black on request Dial Blank dial Special markings Division dials Colour markings/band s 3 (bimetallic movement referred to slave pointer) 1.5 (moving - iron movement) Nominal range of use Ambient temperature C Nominal position + 5% External magnetic field.5 mt Frequency 15-4Hz. Nominal Range of Use Bimetallic Moving - Iron For use on CT (EB 96 /72) 1 A 5 A 1 A 5 A Environmental Conditions With initial and end values marked. Numbering / Lettering. Basic divisions without numbering. Red or Green ----/ 1 A ----/ 5 A Climatic suitability Climatic class 3 according to VDE/VDI 354 Operating temperature Storage temperature Relative humidity Shock resistance Vibration resistance Others Calibrati on Thermal time delay C C < 75% annual average, non-condensing 15g. 11 ms Hz/.15mm 1.5 g at about 5 Hz For other frequencies 15Hz...4 Hz. 8 min. Accessories Safety Terminal Protection Full sized polycarbonate back cover, to provide protection against accidental contact ( hand and fingers ) acc. to IS 9249, VDE 41. Saturating current transformer Saturating transformer accuracy class 3, 5 Hz to protect the movements against continuous overloads. Functional Principle The thermal bimetallic movement indicates the mean rms value over 15 minutes (optional 8 min & 2 min.) and deflects a resettable red slave pointer which shows the maximum value reached. Bimetallic instruments have a specific inertia due to their thermal time lag making these instruments especially suitable to indicate maximum demands or to control long - lasting peak loads. For the measurement of instantaneous rms values, a moving - iron movement with pivot suspension, spring loaded shock absorbing jewel bearing and silicon oil damping is incorported. The moving - iron movment has a response time of approx 1s. Dimensions Dimensions (in mm) Bezel a 72 Case b 66 Depth c 53 BM 72 BM 96 EB 72 EB 96 d 67.5 e 5.5 Cutout Weight (approx.) d b Depth with Back cover kg. f c kg. 64 e a kg kg. 64 Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / VII / 117

12 Analogue Maximum Demand Ammeters with Bimetallic Movement, Combined Bimetallic and Moving - Iron Ammeter Connections Ordering Information Direct - connected L1 N(L2) For use on current Transformer L1 N(L2) Safety Precautions ) Instruments with damaged bezels or window glasses must be disconnected from the mains. 2) Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing. Id non-insulated connector wires are used. 3) The back cover must be snapped into place after connector wired have been clamped for protection against accidental contact. 4) Scales may only be replaced under voltage-free conditions. 5) Bezels and window glasses may only be replaced under voltagefree Conditions. K k l L X X Type Front dimension Measuring Ranges Dial Logo BM 72/96 EB 72/96 Over range Moving Iron- Bimtal movment- Moving iron & bimetal Calibration Calibration Terminal protection Saturating current transformer Maximum demand indicator with bimetallic movement Maximum demand indicator with bimetallic movement 72 mm x 72 mm 96 mm x 96 mm 1 A 5 A --- /1 A for use on Current transformer --- /5A for use on Current transformer Normal glass Antiglare glass Black Red, Blue, Yellow, White Vertical On request Standard scale same as measuring range Blank dial without division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green 2 times rated current 1.2 times rated current 1.2 times rated current 5 Hz For frequency 15-4 Hz 15 min. 8 min. 2 min. RISHABH Full sized polycarbonate back cover Without ESW 1/5A, 4.25 VA ESW 5/5A VA standard Please clearly add the desired specifications while ordering Ordering example EB 96 for use on current transformer 3/5A thermal time delay 15 min. Specifications are subject to change without notice(2/9) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / VII / 117

13 Analogue Pointer - Type Frequency Meter FM 48 FM 72 FM 96 FM 144 Data Sheet Analogue Pointer - Type Frequency Meter Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

14 Analogue Pointer - Type Frequency Meter Application The pointer type frequency meters, FM 48/72 / 96/144 housed in moulded polycarbonate cases are suitable for the measurement of frequencies in the range of 45 to 45 Hz. For maximum accuracy, the essential measuring range is obtained by supressing the unwanted frequency span. These instruments offer several advantages in switchboard and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). Front glass, Bezel & Dial can be easily replaced. Functional Principle Frequencies are measured with a built in electronic transducer & moving coil indicator. Moving coil movement has pivots of very high hardness. Movement is suspended between spring loaded saphire jewels. Movement is properly shielded & critically damped by eddy currents induced in coil former. Electrical Data Mechanical Data Case details Case material Panel fixing Mounting Panel thickness Terminals Moulded square case suitable for mounting in Control / Switchgear panels. Machinery consoles. Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Glass Black Vertical Swivel screws Stackable in a single cutout < 4 mm Hexagon studs, M4 screws And wire clamps E3 Standard Measuring Ranges Frequency Range Rated input voltage Scale and Pointer Pointer Hz Pointer deflection Hz Hz Hz Hz Hz Hz Hz 57.7 V 63.5V 1 V 11 V 115 V 12 V 127 V 28 V 22 V 23 V 24 V 289 V 38 V 4 V 415 V 44 V 44 V Knife - edge pointer Scale characteristics linear * Scale Division Coarse - fine Scale length FM 48 FM 72 FM 96 FM mm 63 mm 97mm 146 mm Electrical Data Measured quantity Frequency Input quantity Alternating voltage in sine waveform Overload capacity (acc. to IS 1248 / IEC 51) Continuously 1.2 times rated voltage Short duration 2 times rated voltage,5 sec Enclosure code IP 52 case (IEC 529) IP for terminals without back cover IP 2 for terminals with back cover Insulation class Group A according to VDE 11 Rated insulation voltage 66V Proof voltage 2KV Installation catagory 6 V CAT III Insulation resistance Power consumption Rishabh Instruments > 5 Mohm at 5 V d.c <=7VA. Accuracy at Reference Conditions Accuracy class.5 according to IS 1248 (IEC 51/ DIN EN 651) Reference conditions Ambient temperature o 23 C + o 2 C Nomial position + 1 o Input Rated Value of measured quantity Other conditions Preheating time Nominal range of use Ambient temperature External magnetic field Voltage Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in IS 1248 (IEC 51/ DIN EN 651) >= 5 min o...5 C Nominal position + 5 o.5 mt Rated Voltage + 2 % 1 / 1 / I / IV / 117

15 Analogue Pointer - Type Frequency Meter Environmental Conditions Climatic suitability Climate category II as per IS 1248 (climatic class 3 according to VDE/VDI 354) o Operating temperature C Storage temperature o C Relative humidity < 75% annual average, non-condensing Shock resistance 15g, 11ms Vibration resistance Hz /.15mm 1.5 g at about 5 H z. Applicable Standards Nominal case and cutout dimensions for IS 2419 indicating Electrical instruments DIN 437 Scale and pointer for electrical measuring IS 1248 instruments DIN 4382 Connections and Terminal markings for IS 1248 panel meters DIN 4387 Terminal bolts / leads. DIN 462/46282 Clamp straps for connections DIN Safety requirements and protective IS 9249 measures for Electrical indicating. DIN 45/8-7, instruments and their accessories. VDE 11/ VDE 41/ 1-76 IEC 529, IEC 11 Performance specifications for direct IS 1248 acting indicating analogue electrical IEC51/DINEN651 measuring instruments and their accessories DIN 4371 Environmental conditions IS 1248 IS 9, Part 5, 7, 8, VDE / VDI 354 Front frames for indicating measuring DIN instruments Principle dimensions UL Combustibility Class UL 94 V- Technical conditions of delivery for DIN 4371 electrical instruments Mechanical strength (Free fall test, IS 1248 / IEC 51 vibration test) IS 9 VDE 411, part 1, Sec. 43/44, IEC 11 E M C compliance as per following standards E N 581-2,EN 582-2,N 5511/CISPR 11, EN ,IEC EN /IEC 1-4-4, EN /IEC 1-4-2, EN /IEC 1-4-5,ENV 514. comply with following european directives 89/336/EEC (EMC directive), 73/23/EEC(low voltage directive) & amendment 93/68/EEC, for CE marking. Options Case Red index pointer Dial Blank dial Special markings Division dials Colour markings/bands Rishabh Instruments Antiglare glass Red,Yellow,Blue,White. Front adjustable on site on request o...18 o With initial and end values marked. Numbering / Lettering. Basic. divisions without numbering. Red or green Accessories Safety Terminal Protection Full sized polycarbonate back cover to provide protection against accidental contact (hand and fingers) acc.to IS 9249, VDE 41. Connections L1 N(L2) Dimensions d Dimensions (in mm) Bezel Case b a b Depth c* d e Cutout Size Depth with Back cover f ** Weight (approx.) c f FM kg. Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in FM a e FM kg..28 kg. FM kg. 1 / 1 / I / IV / 117

16 Analogue Pointer - Type Frequency Meter Ordering Information Safety Precautions Type FM Front dimension Measuring Ranges Terminal protection Dial Logo Pointer type frequency meter 48 mm x 48 mm 72 mm x 72 mm 96 mm x 96 mm 144 mm x 144 mm Refer to table inside Full sized polycarbonate back cover Normal glass Antiglare glass Black Red,Blue,Yellow,White Vertical On request Standard scale same as measuring range Blank dial with division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green RISHABH * Instruments with damaged bezels or window glasses must be disconnected from mains. * Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing, if non - insulated connector wires are used. * The back cover must be snapped into place after the connector wires have been clamped for protection against accidental contact. * Scales should be replaced under Voltage- free conditions. * Bezels and window glasses should be replaced under Voltage - free conditions. Ordering example FM 72 Measuring range Hz, rated voltage AC 23V Specifications are subject to change without notice(2/9) standard Please clearly add the desired specifications while ordering Rishabh Instruments. Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in 1 / 1 / I / IV / 117

17 Analogue Power Factor Meters - LF LF 72 LF 96 LF 144 Data Sheet Analogue Power Factor Meters Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / V / 117

18 Analogue Power Factor Meters - LF Application The moving coil indicators LF 72/96/144 and a phase angle adjuster are used to monitor changing power factor conditions on ir-reversible balanced load systems The power factor is indirectly determined by measuring the phase angle ö between current and voltage (both sinusoidal). However the indicators are calibrated in values of cos ö of the angle ö. These meters offer several advantages in Switchboard & Generating Set panels.number of meters can be mounted in a single Cut out (Mosaic Mounting).The Bezel,Front window glass and Dial can be easily replaced Applicable Standards Nominal case and cutout dimensions for indicating electrical instruments. IS 2419 DIN 437 Scale and pointer for electrical measuring instruments. IS 1248 DIN 4382 Connections & terminal markings IS 1248 for panel meters DIN 4387 Terminal bolts / leads DIN 462/46282 Clamp straps for connections. DIN Safety requirements and protective measures for Electrical indicating instruments and their acessories. Performance specifications for direct acting indicating analogue electrical measuring instrumentsand their accessories Front frames for indicating measuring instruments principle dimensions. Technical conditions of delivery for electrical instruments. UL Combustibility class. Mechanical strength (Free fall test, vibration test) IS 9249 DIN 45 / 8-7 VDE 11 /11-72 VDE 41 /1-76 IEC 529,IEC 11 IS 1248 IEC 51/DIN EN 651 DIN 4371 DIN DIN 4371 UL 94 V-O IS 1248, IEC 51 IS 9 VDE 411, part I, Sec.43/44.IEC 11 Electro Magnetic Compatibility(EMC)Compliance as per following standards- EN 581-2,EN 582-2,EN 5511/CISPR 11, EN ,IEC 555-2, EN / IEC 1-4-4, EN / IEC 1-4-2, EN / IEC 1-4-5, ENV 514. Comply with following European directives 89/336/EEC( EMC directive),73/23/eec(low voltage directive)&amendment 93/68/EEC, for CE marking. Scale and Pointer Pointer Pointer deflection... 9 Scale characteristics Scale division Scale length Interchangeability Mechanical Data Case details Case material Panel fixing Mounting Panel thickness Terminals Electrical Data Measured quantity Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Moulded square case suitable for mounting in Control / Switchgear panels, Machinery consoles. Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Rishabh Instruments 1 / 1 / I / V / 117 Glass Black Vertical Swivel screws. Stackable in a single cutout < 4 mm Hexagon studs, M4 screws and wire clamps E3 (DIN 46282) Power Factor Overload capacity (acc to IS 1248/ IEC 51/ DIN EN 651) Continuously Short duration Power consumption(approx)- Current path < 1. VA Voltage path < 3. VA Enclosures code (IEC 529) insulation class Rated insulation voltage Proof voltage testing Installation catagory (IEC 11) Insulation resistance 1.2 times rated voltage / current 2 times rated voltage, 5 Sec max 1 times rated current, 5 Sec max IP 52 case IP for terminals without backcover IP 2 for terminals with backcover Group A according to VDE V 2 kv 3 VCAT III Knife - edge pointer Non - Linear Coarse-fine LF72 63mm LF96 97mm Scales are interchangeble. > 5 Mohm at 5 V d.c. LF mm

19 Analogue Power Factor Meters - LF Accuracy at Reference Conditions Accuracy class Reference conditions Ambient temperature Waveform Nominal range of use Ambient temperature External magnetic field Voltage Current Environmental Conditions 1.5 according to IS1248 (IEC 51/ DIN EN 651) 23 C + 2 C Nominal position + 1 Sinewave Distortion Factor <= 1 % current % rated current warmup >= 5 minutes at min 8 % of rated current and 1 % of rated voltage. Voltage Rated voltage + 2% Frequency 5 Hz +/ -.1% Others IS 1248 (IEC 51/ DIN EN 651) Frequency Climatic suitability Operating temperature Storage temperature Relative humidity Shock resistance Vibration resistance... 5 C Nominal position mt Rated voltage + 15% 2 to 12 % of rated current Hz for single phase Hz for 3 phase Climate category II as per IS 1248 (climatic class 3 according to VDE / VDI 354) C C < 75% annual average, non-condensing 15g. 11ms Hz/.15 mm 1.5 g at about 5 Hz. Standard Measuring Ranges Type E D Measuring Ranges COS ö COS ö COS ö Rated Voltage Single phase system 3 phase system balanced load cap o.5 ind cap o.3 ind cap o.8 ind Following single phase and three phase voltages are available as standard. The voltages will be considered as a phase voltage(between phase & Neutral) in case of single phase meters and as a line voltage (between two phases) in case of multi phase 2 wire, 3 wire and 4 wire meters. Please clearly specify the application (3 ph. 2 wire,3 wire or 4 wire) Rated Current A 5A Options Case Red index pointer Dial Blank dial Special markings Division dials Colour markings/bands Antiglare glass Red, Yellow, Blue, White Front adjustable on site on request...18 With initial and end values marked. Numbering /Lettering. Basic divisions without numbering. Red or green. Accessories Safety terminal protection Full sized polycarbonate back cover to provide protection against accidental contact (hand and fingers) acc to IS 9249 VDE 41 Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / V / 117

20 Analogue Power Factor Meters - LF Functional Principle Dimensions The measuring system comprises a moving coil indicator & phase angle converter attached to the case of indicating instrument. moving coil movements has pivots of very high hardness movement is suspended. between spring loaded saphire jewels. movement is properly shielded & critically damped by eddy currents induced in coil former. d b a Schematic Diagram. c f e A current transformer 1 of the phase angle converter provides input current to the electronic circuit. Both the input voltage and the current are passed to a bistable filp-flop stage 2. The pulse duty cycle of flip-flop is proportional to the phase angle.a low pass filter allows the mean value which is proportional to the phase angle and is fed to the moving coil movement 3. Connections LF 72/96/144 Single phase L1 N(L2) LF 72/96/144 three phase balanced load k K I L X Dimensions (in mm) LF 96 LF 144 Bezel a Case b Depth c d e Cutout Size Depth with Back cover f Weight (approx.).55 kg..6 kg..8 kg. Safety Precautions LF 72 * Instruments with damaged bezels or window glasses must be disconnected from mains. * Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing, if non - insulated connector wires are used. * The back cover must be snapped into place after the connector wires have been clamped for protection against accidental contact. * Scales should be replaced under Voltage - free conditions. * Bezels and window glasses should be replaced under Voltagefree conditions Specifications are subject to change without notice(2/9) L1 L2 L3 k K I L X X X Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / V / 117

21 Analogue Power Factor Meters - LF Ordering Information Type LF Front dimension 72, 96 and 144 Type E D Measuring ranges (COS ) Terminal protection Rated voltages Rated currents Dial Logo Power Factor meter 72 mm x 72 mm 96 mm x 96 mm 144mm x 144mm Single phase systems 3 phase system balance load cap ind cap ind, cap ind full sized polycarbonate back cover Refer to table inside 1A, 5A Normal glass Antiglare glass Black Red, Blue, Yellow, White Vertical On request Standard scale same as measuring range Blank dial with division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green RISHABH standard Please clearly add the desired specifications while ordering Ordering example LF 96 D for 3 phase 4 wire system balanced load,measuring range ( cos ö ) cap ind,rated voltage AC 23 V, rated current 1A. Specifications are subjects to change without notice (2/9) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

22 Power Meters Active - Reactive - LM LM 96 LM 144 Data Sheet Analogue Watt Meters 9 Scale Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

23 Power Meters Active - Reactive - LM Application The Watt meters, LM96/144 are offered for the AC systems -single phase -3 phase balanced load 3 or 4 wire -3 phase unbalanced load 3 or 4 wire These instruments are suitable to indicate forward (export / out going) and reverse (import / in coming) power flow. They can be used both on sinusoidal and non - sinusoidal current These meters offer several advantages in Switchboard and Generating Set panels. Number of meters can be mounted in a single Cut out (Mosaic Mounting).The Bezel, Front window glass and Dial can be easily replaced Applicable Standards Nominal case and cutout dimensions for indicating electrical instruments. Scale and pointer for electrical measuring instruments. Connections and Terminal markings for panel meters. Terminal bolts / leads Clamp straps for connections. Safety requirements and protective measures for Electrical indicating instruments and their acessories. Performance specifications for direct acting indicating analogue electrical measuring instrumentsand their accessories Front frames for indicating measuring instruments principle dimensions. Technical conditions of delivery for electrical instruments. UL Combustibility class. Mechanical strength (Free fall test, vibration test) Environmental conditions IS 2419 DIN 437 IS 1248 DIN 4382 IS 1248 DIN 4387 DIN 462/46282 DIN IS 9249 DIN 45 / 8-7 VDE 11 /11-72 VDE 41 /1-76 IEC 529,IEC 11 IS 1248 IEC 51/DIN EN 651 DIN 4371 DIN DIN 4371 UL 94 V-O IS 1248, IEC 51 IS 9 VDE 411, part I, Sec.43/44.IEC 11 IS 1248 IS 9, Part 5,7,8 VDE / VDI 354 Electro Magnetic Compatibility(EMC)Compliance as per following standards- EN 581-2,EN 582-2,EN 5511/CISPR 11, EN ,IEC 555-2, EN / IEC 1-4-4, EN / IEC 1-4-2, EN / IEC 1-4-5, ENV 514. Comlpy with following European directives 89/336/EEC( EMC directive),73/23/eec(low voltage directive)&amendment 93/68/EEC, for CE marking. Scale and Pointer Pointer Knife pointer Pointer deflection... 9 Scale characteristics Linear Scale division Coarse-fine Scale length LM96 97mm LM mm Mechanical Data Case details Case material Panel fixing Mounting Panel thickness Terminals Electrical Data Measured quantity Active / Reactive Power Response time 4s max. Overload capacity (acc to IS 1248/ IEC 51/ DIN EN 651) Continuously 1.2 times rated voltage / current Short duration 2 times rated voltage, 5 Sec max 1 times rated current,5 Sec max Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Moulded square case suitable for mounting in Control / Switchgear panels, Machinery consoles. Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-. Glass Black Vertical Swivel screws. Power consumption(approx)- Current path <.2 VA Voltage path types E1W, D1W, D1B, V1W, V1B < 3. VA E1B < 3.5 VA D2W, D2B < 3.4 VA V3W < 3.9 VA V3B < 4.3 VA Enclosures code (IEC 529) insulation class Rated insulation voltage Proof voltage testing Installation catagory (IEC 11) insulation resistance Stackable in a single cutout < 4 mm Hexagon studs, M4 screws and wire clamps E3 IP 52 case IP for terminals Group A according to VDE V 2 kv 3 VCAT III > 5 Mohm at 5 V d.c. Rishabh Instruments 1 / 1 / I / IV / 117

24 Power Meters Active - Reactive - LM Accuracy at Reference Conditions Accuracy class Reference conditions Ambient temperature Input Feasibility factor Power factor Voltage Frequency Current Environmental Conditions Options 1.5 according to IS1248 (IEC 51/ DIN EN 651) 23 C + 2 C Nominal position + 1 Full-scale power value Pw or Pb "Lambda"=Pw/Ps or Pb / Ps Cos ö = for Watt meters & Sin ö = for Var meters Rated voltage + 2% Hz (5 Hz +.1% for E1B) 2% to 12% of rated current Others IS 1248 (IEC 51/ DIN EN 651) Electrical and mechanical zero point in the meter are not necessarily identical. Zero adjustment should be done when only voltage is applied and current circuit not energised. Nominal range of use Ambient temperature External magnetic field Voltage Power factor Frequency Climatic suitability Operating temperature Storage temperature Relative humidity Shock resistance Vibration resistance Case Red index pointer Dial Blank dial Special markings Division dials Colour markings/bands... 5 C Nominal position mt Rated voltage + 15% Cos ö = 1 to.5 (ind.) for active power Sin ö = 1 to.5 (ind.) for reactive power Hz (5 Hz + 1% for E1B) Climate category II as per IS 1248 (climatic class 3 according to VDE / VDI 354) C C < 75% annual average, non-condensing 15g. 11ms Hz/.15 mm 1.5 g at about 5 Hz. Antiglare glass Red,Yellow,Blue,White Front adjustable on site on request...18 With initial and end values marked. Numbering /Lettering. Basic divisions without numbering. Red or green. Standard Measuring Ranges Type Active power Single phase system E1W E1B 3 phase 3 wire system balanced load D1W D1B 3 phase 4 wire system balanced load V1W V1B 3 phase 3 wire system unbalanced load D2W D2B 3 phase 4 wire system unbalanced load V3W V3B selection of measuring range Apparant power Ps is calculated from primary ratings of current transformer and voltage transformer. In single phase network, Ps = V. I where V = voltage between phase and neutral & I = line current. In three phase network, Ps = v3 V. I where V = voltage between two phase & I = line current. Full scale value i.e range of the instrument ( Pw = active power, Pb = reactive power) must be selected in such a way that the same remain between.5 times and 1.2 times the value of apparent power Ps. Thus feasibility factor "Lambda" should be between.5 and 1.2 where "Lambda" = Pw/Ps or Pb/Ps Full scale values shall preferably be selected from standard series according to DIN 4371, and their decadic / decimal multiples. Rated voltage- For Single phase(e1w, E1B) , 63.5, 1, 11, 127, 22, 289, 38. For Three phase (D1W, D1B, - 1, 11, 22, 24, 38, 415, D2W, D2B, V1W, V1B, V3W, V3B) 5. The voltage will be considered as a phase voltage (between phase an neutral) in case of single phase meters and as a line voltage (between two phases) in case of multi phase (2 wire, 3 wire and 4 wire) meters. Rated current- Safety Precautions Reactive power 1A OR 5 A If used on current transformer, please state transformer ratio on the order. * Instruments with damaged bezels or window glasses must be disconnected from mains. * Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing, if non - insulated connector wires are used. * Scales should be replaced under Voltage- free conditions. * Bezels and window glasses should be replaced under Voltage - free conditions Specifications are subject to change without notice(2/9) Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

25 Power Meters Active - Reactive - LM Ordering Information Type LM Front dimension 96 and 144 Type Measurng ranges Rated voltages Rated currents E1W D1W V1W D2W V3W E1B D1B V1B D2B V3B Watt and Var meter,9 o 96 mm x 96 mm 144mm x 144mm Specify while ordering Refer to table inside 1A, 5A Normal glass Antiglare glass Black Red,Blue,Yellow,White Scale Single phase systems 3 phase 3 wire system balanced load 3 phase 4 wire system balanced load 3 phase 3 wire system unbalanced load 3 phase 4 wire system unbalanced load Vertical On request Dial Logo Standard scale same as measuring range Blank dial with division Additional lettering on request Additional numbering on request Coloured marking red or green Coloured sector red or green RISHABH standard Please clearly add the desired specifications while ordering Ordering Example LM 96 D V3W for active power 3 phase 4 wire system unbalanced load,measuring range kw, voltage AC 44 V, for use on current transformer 6/5A. Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

26 Power Meters Active - Reactive - LM Functional Principle For active and reactive power measurement, a moving-coil indicator is used to indicate watts and vars for which an analogue DC signal is obtained from a power converter attached to the case of the indicator. Schematic diagram. Connections The power converter uses one, two or three for multiplier systems 2 depending on the measurement of balanced or unbalanced load AC systems. Current transformers 1 provide the input current to the multiplier circuit. The multipliers form the product of the instantaneous values of current and voltage (TDM principle). The product resultant is integrated, thereby suppressing the AC ripple. Subsequently product proportional output is delivered to 3.There the voltage is converted into Current, whose magnitude also depends on Feasibility Factor ( ). Finally this current is fed to the moving coil movement, 4. For the instrument DC power supply is obtained from input voltage, 5. Dimensions b d b a a c e Dimensions (in mm) LM 96 Bezel a 96 Case b 9 Depth c 16 X d 91.5 e 5.5 Cotout Size Depth with Back cover f 64 X X L, Weight (approx.) kg kg. Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Rishabh Instruments 1 / 1 / I / IV / 117

27 Syncroscope Rish - SQ SQ 96 SQ 144 Data Sheet Electronic Synchroscope Page 1 of 3 Version 1/1/II/X/912-A

28 Application The Electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS Voltage(reference voltage) & the GENERATOR Voltage(incoming voltage) It denotes the actual frequency difference corresponding to the inverse of time taken for one rotation of the illuminated vector spot. When two alternators are paralleled,it is necessary that, 1)Frequency must be equal. 2)Phase must be same. Sychroscope is,hence used to indicate the Phase & Frequency difference between two AC alternators,which are to be paralleled. Description he rotation of the vector spot is with reference to the bus voltage. If the vector spot LED turns clockwise,it indicates the GENERATOR frequency is greater than the BUS frequency. It means the speed of the generator must be reduced by the operator. If the spot LED turns anticlockwise,the GENERATOR frequency is less than BUS frequency.in this case speed of the generator must be increased. If T is the time taken for one rotation, the frequency difference can be calculated as 1/ T = A f Example Let the bus frequency be 5 Hz.The vector spot takes 1 Sec. for one rotation,clockwise. 1/1 =.1 Hz. The frequency difference =.1Hz. Hence we can infer that GENERATOR frequency is 5.1 Hz. If the Frequency & Phase of BUS signal matches with those of GENERATOR signal,the two green led s at 12 o clock position glow. If the Frequency matches & Phase does not, then one red led corresponding to the phase difference will glow. Favorable condition for" Switching in" the Generator 1. Ensure that the frequency difference between two inputs is within the requirements of user as follows Measure time taken for 1 complete rotation of the vector spot insecond(t). The frequency difference will be Af = 1/T(Hz) 2. Provided the frequency difference is within acceptable limits,wait till the SYNC mark LED s(two green LED s at 12 o clock position)glow. At this instant, it is safe to CONNECT the GENERATOR to BUS Functional Principle Input I Input II Power Supply I Power Supply II Phase / LED Adjustment Frequency Display Network Detector The Bus & Gen inputs are fed to the Frequency & Phase detection network.the output duty cycle of the network corresponds to the frequency difference between Bus & Generator Voltage. The detector network also determines the actual phase difference. Mechanical Data Case details Case material Panel fixing Mounting Panel thickness Terminals Moulded square case suitable for mounting in Control / Switchgear panels, machinery consoles. Glass filled polycarbonate, flame retardant and drip proof as per UL 94 V-O. Glass Black Vertical Swivel screws. Stackable in a single cutout < 4 mm Hexagon studs, M4 screws and wire clamps E3 (DIN 46282) Electrical Data Measured quantity Frequency & Phase difference Power consumption 6 VA Max Enclosures code IP 52 case (IEC 529) IP for terminals Insulation class group A according to VDE 11 Insulation voltage 66 V Proof voltage 2kV Frequency range 35-7 Hz Pull in / drop out Freq. + / - 9 Hz Installation catogory 3 V CAT III (IEC11) insulation resistance > 5 Mohm at 5 V d.c. Reference conditions Ambient temperature 23 C + 3 C Input Voltage Rated voltage + 2% Rated frequency 5 Hz +.1 % Environmental Conditions Climatic suitability Climate category II as per IS 1248 (climatic class 3 according to VDE / VDI 354) Operating temperature C Storage temperature C Relative humidity < 75 % annual average non - condensing Shock resistance 15g, 11ms Vibration resistance Hz /.15 mm / 5 Cycles / 1 octave per minute. Applicable Standards Nominal case and cutout dimensions for IS 2419 indicating measuring instruments DIN 437 Connections and Terminal markings for IS 1248 panel meters DIN 4387 Terminal bolts / leads. DIN 462/46282 Clamp straps for connections DIN Safety requirements and protective- IS measures for Electrical indicating- DIN 45 / 8-7, instruments and their accessories. VDE 11/ VDE 41/ 1-76 IEC 529, IEC 11 Performance specification for direct IS acting indicating analogue electrical IEC 51/DIN EN 651 measuring instrument and their accessories Environmental conditions IS IS 9 VDE / VDI 354 Front frames for indicating measuring DIN instruments principal dimensions UL Combustibility Class UL 94 V- Technical conditions of delivery for DIN 4371 electrical instruments Mechanical Strength IS 1248/IEC 51 (Free fall test,vibration test) IEC 11, IS VDE 411,part 1 Sec 43/44 Options Case Colour of LED s Dial Special markings Antiglare glass Red,Yellow,Blue,White. Orange,Yellow Numbering / Lettering. Page 2 of 3 Version 1/1/II/X/912-A

29 Connections Dimensions Type Terminal BUS GEN SQ 96 SQ V 24V 48V 11V 127V 38V 22V 415V 1V 12V Ordering Information Type SQ Electronic Sychroscope Front Dimension 96, mm x 96 mm, 144 mm x 144 mm Rated voltages Refer to selection table inside Normal glass Antiglare glass Colour of Bezel Black Red, Blue, Yellow, White Vertical (-36 ) Dial Additional lettering on request Additional numbering on request Logo RISHABH,for Indian Sales. C.G,for export through Crompton Greaves I.D. Others Standard *2 Please clearly add the desired specifications while ordering Ordering example SQ 96, rated voltage AC 23 V. Specifications are subject to change without notice(1/98) Dimensions (in mm) SQ 96 SQ 144 Bezel a p96 p144 Case b p9 p136 Depth c d p 91.5 p137.8 e Cutout Size +.8 p p 138 Weight (approx.).6kg.7kg Safety Precautions Instruments with damaged bezels or window glasses must be disconnected from mains. Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing,if non-insulated connector wires are used. Bezels and window glasses should be replaced under Voltage - free conditions. Page 3 of 3 Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Version 1/1/II/X/912-A

30 Analogue Meters With Moving Iron Movement Two in One EQ - 96 Data Sheet Analogue Meters with Moving Iron Movement RISHABH INSTRUMENTS PVT.LTD. F-31, MIDC, Satpur, Nashik-422 7, India. Tel , Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in Web Page 1 of 4 1 / 1 / I / XV / 71 / A

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Technical Data Sheet Sigma Series DS Meter

Technical Data Sheet Sigma Series DS Meter Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments

More information

SIGMA SERIES DE METER

SIGMA SERIES DE METER SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DG Meter Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear

More information

Technical Data Sheet Sigma Series DE Meter

Technical Data Sheet Sigma Series DE Meter Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency

More information

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic

More information

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96 Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide

More information

Smart Look Series Meter

Smart Look Series Meter File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement

More information

PLATINUM SERIES SWITCHBOARD METERS

PLATINUM SERIES SWITCHBOARD METERS PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter 212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter C R LISTED File No. E471457 Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

Standard Program Technical Description

Standard Program Technical Description Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable Scales Meter s scale

More information

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard

More information

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES AMMETERS and VOLTMETERS MA12 MA19 MA17 MA16 MB16 MA16, MB16, MA17, MA19 and MA12 moving-coil meters are intended for measuring

More information

Century Style Analog Panel Meters

Century Style Analog Panel Meters UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &

More information

Do not risk your safety!

Do not risk your safety! Analog Panelmeters Do not risk your safety! ANALOG PANELMETERS ANALOG G Analog Panelmeters ANALOG PANELMETERS Features For measurement of AC currents and voltages Good read-out survey on larger distance

More information

Square Shape Instrument - PK Series

Square Shape Instrument - PK Series Square Shape Instrument - PK Series PK-series is a square type meter. 4 difference degree type for this square PK-series:120mm, 100mm, 80mm & 60mm. Panel cut dimension is conformity with JIS C 1103. PK

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65 tech Transformer Manufacturer Sdn. Bhd. Flood Light Model: S70150 - MH70W S70150 - MH150W Specification: Ingress Protection: IP65 Voltage: 220V ~ 240VAC 50Hz Lamp Wattage: 70W ~ 150W Holder Type: RX7s

More information

Price List Effective from :

Price List Effective from : List Effective from :- 01-04-2018 INDICATING MOVING IRON, MOVING COIL VOLTMETER & AMMETER ME BRAND Moving Iron Instruments are generally used for measuring A.C. Voltage and currents. These are Repulsion

More information

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2 Panel Meter SPECIFICATIONS/ORDERING INFORMATION Crompton AC Overload Ammeters X6 Overload Scaling for Motor Start Duty True RMS Reading, Self Contained 50/60Hz 3 1 /2", 3 /16 DIN & 1 /4 DIN sizes Fiesta Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ Accuracy

More information

Wind display type WSDI-2 DATA SHEET

Wind display type WSDI-2 DATA SHEET Wind display type WSDI-2 DATA SHEET Displays Read-out Approval Housing Relative or true wind speed and direction Wind speed in: m/s, knots or Beaufort Black base, white lines and figures 4-digit 7-segment

More information

Basic Series Accessories Low Voltage Current Transformer Class 1

Basic Series Accessories Low Voltage Current Transformer Class 1 Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating

More information

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO M Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO GSAFETY WARNINGS The circuit under test must be switched off and de-energised before test connections are made

More information

Portable Instruments. Bulletin 2000-E

Portable Instruments. Bulletin 2000-E Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays Displays Relative or true wind speed and direction Wind speed in: m/s, knots or Beaufort Read-out Black base, white lines and figures 4-digit 7-segment red display Approval Major class approvals, see homepage

More information

Product Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.

Product Information. Viewline Temperature gauges.  Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature. Product Information www.vdo.com Viewline Temperature gauges Description Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature. Features _ Integrated Warning LED. _ Changeable Frontbezels.

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant Elapsed Time Meters Devices will match the frequency of AC power systems. Six-digit counters record hours, tenths of hours, minutes

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

LED Digital Analog Combination

LED Digital Analog Combination Crompton Instruments model 007-DI features a combination of the traditional 250 4 1 2" switchboard indicator with the trend indication plus the benefits of wide angle LED visibility. This rugged shock

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target

More information

EKT112 Principles of Measurement and Instrumentation. Power Measurement

EKT112 Principles of Measurement and Instrumentation. Power Measurement EKT112 Principles of Measurement and Instrumentation Power Measurement 1 Outline Power? Power in DC and AC Circuits Power Measurements Power Instrumentation (Wattmeter) 2 Concept of Electric POWER Power

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

240 Series DIN Panel Meters

240 Series DIN Panel Meters An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering measurement of all electrical and electronic parameters. Meters are shock resistant and vibration proof and supplied with terminal

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

2. Analog measurement of Electrical Quantities

2. Analog measurement of Electrical Quantities 2.1. Classification of Analog Instruments Definition and concept of Measurement The analog instruments can be classified on the basis of various parameters. Analog Instruments On the basis of measuring

More information

Modulating control valve PN16 with magnetic actuator

Modulating control valve PN16 with magnetic actuator Modulating control valve PN with magnetic actuator for hot and chilled water with positioning control and position feedback MP80FY MP00FY Mixing or straight-through valves DN80 and DN00 with magnetic actuator

More information

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution. 88 Metering Solution-Oriented Metering Keeping track of onboard systems is critical to safety and peace of mind. Running low on fuel or not knowing about a failing battery can lead to dangerous situations.

More information

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2... Type 499 Pneumatic Timer Low-cost DIN dimensions Requires little space for installation Pressure-independent No continuous air supply equired Stationary preset value TECHNICAL DATA Display digit roll Time

More information

Technical information

Technical information Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary

More information

Crompton Greaves Limited

Crompton Greaves Limited Commercial Motors By FHP Motors Division Smart solutions. Strong relationships. Crompton Greaves Limited Single Phase Motors Range Product Parameters/Features 1. Voltage a. 90V to 130V b. 190 to 240 V

More information

Panel Meters and Accessories Digital Panel Meter

Panel Meters and Accessories Digital Panel Meter Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor

More information

MEASURING INSTRUMENTS. Basic Electrical Engineering (REE-101) 1

MEASURING INSTRUMENTS. Basic Electrical Engineering (REE-101) 1 MEASURING INSTRUMENTS Basic Electrical Engineering (REE-101) 1 MEASURING INSTRUMENTS The device used for comparing the unknown quantity with the unit of measurement or standard quantity is called a Measuring

More information

Screw-in resistance thermometers with plug connector

Screw-in resistance thermometers with plug connector Data Sheet 90.2004 Page 1/8 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available

More information

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. Experiment o. 1 AME OF THE EXPERIMET To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. OBJECTIVE 1. To be conversant with the constructional detail and working of common

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control CEP7 Solid-State Overload Relay for Motor Control Centers and Technical Data Description Page Product Description.............................................. 2 Specifications...................................................

More information

PA39 TYPE PANEL POWER METERS APPLICATION CHOICE OF MEASURING RANGE TECHNICAL DATA. Additional errors

PA39 TYPE PANEL POWER METERS APPLICATION CHOICE OF MEASURING RANGE TECHNICAL DATA. Additional errors PANEL POWER METERS PA39 TYPE Additional errors acc. EN 60051-1 standard Power consumption: - voltage circuit 3 VA - current circuit 0.25 VA Protection Grade acc. to EN60529 Front protection grade: - IP

More information

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak

More information

Tel: &

Tel: & C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer

More information

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No 029,1*,521 92/70(7(5 :,7+ &+$1*( 29(5 6:,7&+ 72VS, 96VS, 144sVS, 72VS-1, 96VS-1, 144sVS-1 The instruments are suitable for measuring AC voltages in 4 or 3-wire networks by using a change over switch mounted

More information

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Page 1 of 2 Ref: IW012346 Rev 4 July 03 Indicators Saxon & Fiesta Series Products Covered 012-**, 013-**, 014-** & 016-** Installation The product should be panel mounted using the mounting kit provided.

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc. POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I

More information

ELECTRICAL MAINTENANCE

ELECTRICAL MAINTENANCE ELECTRICAL MAINTENANCE II PRACTICAL JOURNAL DATA 1 EXPERIMENT NO. 1 AIM: TO FIND VOLTAGE RATIO OF A GIVEN TRANSFORMER. CIRCUIT DIAGRAM: OBSERVATION TABLE: Sr.No. 1 2 3 4 Primary Voltage (V 1 ) Secondary

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Chapter 9 Basic meters

Chapter 9 Basic meters Chapter 9 Basic meters Core Competency Units UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE004B Solve problems in multiple path DC Circuits Essential Knowledge and Associated

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Modulating control valve PN16

Modulating control valve PN16 8 Modulating control valve PN with magnetic actuator for HTHW and steam, with positioning control and position feedback MH...FY...N Control valve with magnetic actuator for modulating control in district

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

AE105 PRINCIPLES OF ELECTRICAL ENGINEERING JUNE 2014

AE105 PRINCIPLES OF ELECTRICAL ENGINEERING JUNE 2014 Q.2 a. Explain in detail eddy current losses in a magnetic material. Explain the factors on which it depends. How it can be reduced? IETE 1 b. A magnetic circuit with a single air gap is shown in given

More information

Single-phase CT current transformers Cat. Nos :

Single-phase CT current transformers Cat. Nos : Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type

More information

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications: CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:

More information

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines EM readyapply SELFTEST W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES PROK DEVICES PRIVATE LIMITED B-80, 2 nd & 3 rd Floor, KSSIDC Industrial estate, 4 th Main Road, 6 th Block, Rajaji Nagar, Bengaluru -560010 Ph no: 080-41480777, 080-41157700, Email:,, www.prokdvs.in DIP

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information